JACKSON SAFETY * SHADOWAIRE * II Powered Air Purifying Respirator (PAPR) Featuring JACKSON SAFETY* W60 NEXGEN* digital ADF Comfort & Protection All-in-One The JACKSON SAFETY* SHADOWAIRE* II Powered Air Purifying Respirator (PAPR) provides comfort while protecting you from harsh work environments. Lightweight and built for durability for even the toughest of jobs. Features: Welding helmet featuring the JACKSON SAFETY* premium W60 series digital auto-darkening filter. Filter automatically detects weld arc and switches to weld shade. Expanded protection with integrated settings for welding, torch cutting and grinding and continuous IR/UV protection for eyes even in the off state. Lightweight blower unit with adjusting waist belt Audible alarm signals user when need new filter or battery charge. Three filters providing NIOSH approved HE filtration from particulate contaminants. Durable breathing hose provides filtered air to the wearer during use. Lightweight NiMH battery provides 4 or 8 hr power with no memory retention. Battery smart charger prevents overcharging of batteries with auto-shutoff. Storage bag keeps entire unit secure and clean during non-use.

Transcript of JACKSON SAFETY SHADOWAIRE II · 2011-06-07 · JACKSON SAFETY* SHADOWAIRE* II Powered Air Purifying...

Page 1: JACKSON SAFETY SHADOWAIRE II · 2011-06-07 · JACKSON SAFETY* SHADOWAIRE* II Powered Air Purifying Respirator (PAPR) Featuring JACKSON SAFETY* W60 NEXGEN* digital ADF Comfort & Protection

JACKSON SAFETY* SHADOWAIRE* II

Powered Air Purifying Respirator (PAPR)

Featuring JACKSON SAFETY*

W60 NEXGEN* digital ADF

Comfort & Protection All-in-OneThe JACKSON SAFETY* SHADOWAIRE* II Powered Air Purifying Respirator (PAPR) provides comfort while protecting you from harsh work environments. Lightweight and built for durability for even the toughest of jobs.

Features:

• Welding helmet featuring the JACKSON SAFETY* premium W60 series digital auto-darkening filter. Filter automatically detects weld arc and switches to weld shade.

• Expanded protection with integrated settings for welding, torch cutting and grinding and continuous IR/UV protection for eyes even in the off state.

• Lightweight blower unit with adjusting waist belt

• Audible alarm signals user when need new filter or battery charge.

• Three filters providing NIOSH approved HE filtration from particulate contaminants.

• Durable breathing hose provides filtered air to the wearer during use.

• Lightweight NiMH battery provides 4 or 8 hr power with no memory retention.

• Battery smart charger prevents overcharging of batteries with auto-shutoff.

• Storage bag keeps entire unit secure and clean during non-use.

Page 2: JACKSON SAFETY SHADOWAIRE II · 2011-06-07 · JACKSON SAFETY* SHADOWAIRE* II Powered Air Purifying Respirator (PAPR) Featuring JACKSON SAFETY* W60 NEXGEN* digital ADF Comfort & Protection

JACKSON SAFETY* warrants all products to be free from defects in material and workmanship under normal conditions for one year from the date of purchase, with the exception of the auto-darkening lens, whichJACKSON SAFETY* warrants to be free from defects in material and workmanship for a period of two years from the date of purchase. The auto-darkening lens that fails to perform as specified in the instruction manual during this time will be replaced at no charge. Warranty does not apply to lenses subjected to misuse or misapplication.

THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING WARRANTY OF FITNESS AND WARRANTY OF MERCHANTABILITY. ®/* Trademarks of Kimberly-Clark Worldwide, Inc. or its affiliates. Marques déposées de Kimberly-Clark Worldwide, Inc. ou de ses filiales. K01985 K4343-10-01 09/10

Our Guarantee

Your total satisfaction means everything to us. If, for any reason, our products do not meet your expectations, Kimberly-Clark will reimburse you‡ for your initial purchase, via FREE product, for up to $1,000.

For more information on KIMBERLY-CLARK PROFESSIONAL*, visit us online at www.kcprofessional.com, contact your Kimberly-Clark Sales Representative, or call us at 1-888-346-GOKC (4652).

‡ Guarantee extended to consuming end-user accounts only.

For complete product warning information, please refer to www.kc-safety.com

Product Code Lens Filter Initial

Flow RateActual

Flow RateBattery

LifeCharging

Time Charges Alarms Certification Blower Dimensions Weight

3002551

Digital ADF HE

Meets the NIOSH minimum flow

rate of >170 LPM / 6+ CFM

275 LPM

4 Hours < 3.5 hrs

> 500 Audible NIOSH 42 CFR Part 84

L: 4.74” W: 4.86” H: 2.10”

Blower with filters 2.99lb (1.36kg)

Total: 6.6lb (3.0 kg)

3002552 8 Hours < 10.5 hrsBlower with filters

2.99lb (1.36kg) Total: 7.58lb (3.4 kg)

JACKSON SAFETY* SHADOWAIRE* II Powered Air Purifying Respirator (PAPR)

Code No. Description

3002551 SHADOWAIRE* II with JACKSON SAFETY* NEXGEN* ADF; 4 hr batteries (2)

3002552 SHADOWAIRE* II with JACKSON SAFETY* NEXGEN*ADF; 8 hr battery (1)

Replacement Parts

3002861 HE Filters (6pk)

3002862 Battery Charger (4 hr)

3002873 Overnight Battery Charger (8hr)

3002864 Face seals (3pk)

3002858 4hr NiMH Battery

3002871 8hr NiMH Battery

3002856 Blower Unit Complete (blower unit, belt, airflow indicator, breathing hose)

3002857 Blower Unit only

3002859 Breathing Hose

3002865 Waist Belt

The JACKSON SAFETY* SHADOWAIRE* II PAPR can help to provide necessary protection in accordance with the new OSHA guidelines regarding hexavalent chromium fumes. These fumes may be produced when welding or cutting on stainless steel and can cause serious respiratory issues without proper protection.

4hr NiMH Battery

Airflow Indicator Belt

Breathing Hose

Battery Charger

Welding Helmet with face seal

Storage Bag

HE Filters

PAPR Comes Complete With:

• Welding Helmet with face seal• JACKSON SAFETY* NEXGEN* ADF • Blower Unit

• Waist Belt• Breathing Hose• HE Filters (3)• Battery Charger (4 or 8 hour)

• Lightweight NiMH battery (two 4 or one 8 hour)

• Air flow Indicator• Storage Bag for entire unit