ANALYTICAL REPORT
Job Number: 420-57832-1
SDG Number: L1213994
Job Description: Newtown Creek
For:
Alpha Analytical
8 Walkup Drive
Westborough, MA 01581
Attention: Mr. Chris Anderson
Renee Cusack
Lab Director
10/17/2012
Revision: 1
Lab Results Lab Resultscc:
The test results in this report meet all NELAP requirements unless specified within the case narrative. Pursuant to NELAP, this
report may not be reproduced, except in full, without the written approval of the laboratory. EnviroTest Laboratories Inc. certifies that
the analytical results contained herein apply only to the samples tested as received by our laboratory. All questions regarding this
report should be directed to the EnviroTest Customer Service Representative.
EnviroTest Laboratories, Inc. Certifications and Approvals: NYSDOH 10142, NJDEP NY015, CTDOPH PH-0554, EPA NY00049
315 Fullerton Avenue, Newburgh, NY 12550
Tel (845) 562-0890 Fax (845) 562-0841 www.envirotestlaboratories.com
Envirotest Laboratories, Inc.
Page 1 of 19
METHOD SUMMARY
Job Number: 420-57832-1Client: Alpha Analytical
Sdg Number: L1213994
Preparation MethodMethodLab LocationDescription
Matrix: Water
SM20 SM 5210B5 Day BOD test EnvTest
SM18 SM 9222BMembrane Filter Technique - Standard Total Coliform
Procedure
EnvTest
SM18 SM 9222DMembrane Filter Technique - Fecal Coliform Procedure EnvTest
SM21 SM5210B*M30 Day BOD Test EnvTest
Lab References:
EnvTest = EnviroTest
Method References:
SM18 = "Standard Methods For The Examination Of Water And Wastewater", 18th Edition, 1992.
SM20 = "Standard Methods For The Examination Of Water And Wastewater", 20th Edition."
SM21 = "Standard Methods For The Examination Of Water And Wastewater", 21st Edition
EnviroTest Laboratories, Inc.
Page 2 of 19
SAMPLE SUMMARY
Client: Alpha Analytical Job Number: 420-57832-1
Sdg Number: L1213994
Client Sample IDLab Sample ID Client Matrix
Date/Time
Sampled
Date/Time
Received
08/07/2012 0925 08/08/2012 0810NC034SW-A-20120807420-57832-1 Water
08/07/2012 1002 08/08/2012 0810NC034SW-C-20120807420-57832-2 Water
08/07/2012 1233 08/08/2012 0810EK014SW-A-20120807420-57832-3 Water
08/07/2012 1253 08/08/2012 0810EK014SW-C-20120807420-57832-4 Water
08/07/2012 1357 08/08/2012 0810EK022SW-A-20120807420-57832-5 Water
08/07/2012 1357 08/08/2012 0810EK1022SW-A-20120807420-57832-6 Water
EnviroTest Laboratories, Inc.
Page 3 of 19
Mr. Chris Anderson
Alpha Analytical
8 Walkup Drive
Westborough, MA 01581
Job Number: 420-57832-1
Sdg Number: L1213994
Client Sample ID:
Analyte Result/Qualifier Unit Dilution
08/08/2012 0810
08/07/2012 0925
Date Received:
Date Sampled:
Lab Sample ID:
NC034SW-A-20120807
RL
Client Matrix: Water
420-57832-1
Method: SM 5210B Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 4.58 mg/L 2.00 1.0
Method: SM5210B*M Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 7.92 mg/L 6.00 3.0
Method: SM 9222B Date Analyzed: 08/08/2012 0900
Coliform, Total 6300 CFU/100mL 100 100
Method: SM 9222D Date Analyzed: 08/08/2012 0900
Coliform, Fecal 4800 CFU/100mL 100 100
Page 5 of 19
Mr. Chris Anderson
Alpha Analytical
8 Walkup Drive
Westborough, MA 01581
Job Number: 420-57832-1
Sdg Number: L1213994
Client Sample ID:
Analyte Result/Qualifier Unit Dilution
08/08/2012 0810
08/07/2012 1002
Date Received:
Date Sampled:
Lab Sample ID:
NC034SW-C-20120807
RL
Client Matrix: Water
420-57832-2
Method: SM 5210B Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand <2.00 mg/L 2.00 1.0
Method: SM5210B*M Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 7.71 mg/L 6.00 3.0
Method: SM 9222B Date Analyzed: 08/08/2012 0905
Coliform, Total 630 CFU/100mL 10.0 10
Method: SM 9222D Date Analyzed: 08/08/2012 0905
Coliform, Fecal 340 CFU/100mL 10.0 10
Page 6 of 19
Mr. Chris Anderson
Alpha Analytical
8 Walkup Drive
Westborough, MA 01581
Job Number: 420-57832-1
Sdg Number: L1213994
Client Sample ID:
Analyte Result/Qualifier Unit Dilution
08/08/2012 0810
08/07/2012 1233
Date Received:
Date Sampled:
Lab Sample ID:
EK014SW-A-20120807
RL
Client Matrix: Water
420-57832-3
Method: SM 5210B Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 9.72 mg/L 6.00 3.0
Method: SM5210B*M Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 22.7 mg/L 8.00 4.0
Method: SM 9222B Date Analyzed: 08/08/2012 0905
Coliform, Total 700 CFU/100mL 100 100
Method: SM 9222D Date Analyzed: 08/08/2012 0905
Coliform, Fecal 600 CFU/100mL 100 100
Page 7 of 19
Mr. Chris Anderson
Alpha Analytical
8 Walkup Drive
Westborough, MA 01581
Job Number: 420-57832-1
Sdg Number: L1213994
Client Sample ID:
Analyte Result/Qualifier Unit Dilution
08/08/2012 0810
08/07/2012 1253
Date Received:
Date Sampled:
Lab Sample ID:
EK014SW-C-20120807
RL
Client Matrix: Water
420-57832-4
Method: SM 5210B Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand <6.00 mg/L 6.00 3.0
Method: SM5210B*M Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 15.8 mg/L 8.00 4.0
Method: SM 9222B Date Analyzed: 08/08/2012 0920
Coliform, Total 4600 CFU/100mL 100 100
Method: SM 9222D Date Analyzed: 08/08/2012 0920
Coliform, Fecal 2900 CFU/100mL 100 100
Page 8 of 19
Mr. Chris Anderson
Alpha Analytical
8 Walkup Drive
Westborough, MA 01581
Job Number: 420-57832-1
Sdg Number: L1213994
Client Sample ID:
Analyte Result/Qualifier Unit Dilution
08/08/2012 0810
08/07/2012 1357
Date Received:
Date Sampled:
Lab Sample ID:
EK022SW-A-20120807
RL
Client Matrix: Water
420-57832-5
Method: SM 5210B Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 7.59 mg/L 6.00 3.0
Method: SM5210B*M Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 21.9 mg/L 8.00 4.0
Method: SM 9222B Date Analyzed: 08/08/2012 0920
Coliform, Total 1190 CFU/100mL 10.0 10
Method: SM 9222D Date Analyzed: 08/08/2012 0920
Coliform, Fecal 1100 CFU/100mL 100 100
Page 9 of 19
Mr. Chris Anderson
Alpha Analytical
8 Walkup Drive
Westborough, MA 01581
Job Number: 420-57832-1
Sdg Number: L1213994
Client Sample ID:
Analyte Result/Qualifier Unit Dilution
08/08/2012 0810
08/07/2012 1357
Date Received:
Date Sampled:
Lab Sample ID:
EK1022SW-A-20120807
RL
Client Matrix: Water
420-57832-6
Method: SM 5210B Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 7.77 mg/L 6.00 3.0
Method: SM5210B*M Date Analyzed: 08/08/2012 1200
Biochemical Oxygen Demand 22.1 mg/L 8.00 4.0
Method: SM 9222B Date Analyzed: 08/08/2012 0920
Coliform, Total 970 CFU/100mL 10.0 10
Method: SM 9222D Date Analyzed: 08/08/2012 0920
Coliform, Fecal 260 CFU/100mL 10.0 10
Page 10 of 19
DATA REPORTING QUALIFIERS
Client: Alpha Analytical Job Number: 420-57832-1
Lab Section Qualifier Description
Sdg Number: L1213994
Biology
Duplicate RPD exceeds the control limitF
EnviroTest Laboratories, Inc.
Page 11 of 19
Definitions and Glossary
Abbreviation These commonly used abbreviations may or may not be present in this report.
%R
DL, RA, RE
EPA
MDL
ND
QC
RL
RPD
Percent Recovery
Indicates a Dilution, Reanalysis or Reextraction.
United States Environmental Protection Agency
Method Detection Limit - an estimate of the minimum amount of a substance that an analytical
process can reliably detect. A MDL is analyte- and matrix-specific and may be
laboratory-dependent.
Not detected at the reporting limit (or MDL if shown).
Quality Control
Reporting Limit - the minimum levels, concentrations, or quantities of a target variable (e.g.,
target analyte) that can be reported with a specified degree of confidence.
Relative Percent Difference - a measure of the relative difference between two points.
EnviroTest Laboratories, Inc.
Page 12 of 19
Quality Control Results
Job Number: 420-57832-1Client: Alpha Analytical
Sdg Number: L1213994
WaterClient Matrix:
1.0Dilution:
Date Analyzed:
Lab Sample ID:
08/08/2012 1200
Method Blank - Batch: 420-58472
Date Prepared:
Instrument ID:
Lab File ID:
Initial Weight/Volume:
Final Weight/Volume:
Analysis Batch: 420-58472
Prep Batch: N/A
mL
mL
N/A
Units: mg/L
Method: SM 5210B
Preparation: N/A
N/A
No Equipment AssignedMB 420-58472/1
Analyte Result Qual RL
<2.00 2.00Biochemical Oxygen Demand
Water
1.0
08/08/2012 1200Date Analyzed:
Lab Control Spike - Batch: 420-58472
Client Matrix:
Lab Sample ID:
Dilution:
Date Prepared:
Instrument ID:
Lab File ID:
Initial Weight/Volume:
Final Weight/Volume:
N/A
Analysis Batch: 420-58472
Prep Batch: N/A
mL
300 mL
Units: mg/L
Method: SM 5210B
Preparation: N/A
N/A
No Equipment AssignedLCS 420-58472/2
Analyte QualLimit% Rec.ResultSpike Amount
198 213.0 108 85 - 115Biochemical Oxygen Demand
mg/LUnits:
Water
Dilution: 1.0
Date Analyzed:
Duplicate - Batch: 420-58472
Lab Sample ID:
Client Matrix:
Date Prepared:
08/08/2012 1200
Instrument ID:
Lab File ID:
Initial Weight/Volume:
Final Weight/Volume:
Analysis Batch: 420-58472
Prep Batch: N/A
mL
mL
N/A
Method: SM 5210B
Preparation: N/A
N/A
No Equipment Assigned420-57832-1
Analyte QualLimitRPDResultSample Result/Qual
4.4804.58 2 20Biochemical Oxygen Demand
EnviroTest Laboratories, Inc.
Calculations are performed before rounding to avoid round-off errors in calculated results.
Page 14 of 19
Quality Control Results
Job Number: 420-57832-1Client: Alpha Analytical
Sdg Number: L1213994
WaterClient Matrix:
1.0Dilution:
Date Analyzed:
Lab Sample ID:
08/08/2012 0900
Method Blank - Batch: 420-58469
Date Prepared:
Instrument ID:
Lab File ID:
Initial Weight/Volume:
Final Weight/Volume:
Injection Volume:
Analysis Batch: 420-58469
Prep Batch: N/A
N/A
Units: CFU/100mL
Method: SM 9222B
Preparation: N/A
N/A
No Equipment AssignedMB 420-58469/1
Analyte Result Qual RL
<1.00 1.00Coliform, Total
CFU/100mLUnits:
Water
Dilution: 100
Date Analyzed:
Duplicate - Batch: 420-58469
Lab Sample ID:
Client Matrix:
Date Prepared:
08/08/2012 0900
Instrument ID:
Lab File ID:
Initial Weight/Volume:
Final Weight/Volume:
Injection Volume:
Analysis Batch: 420-58469
Prep Batch: N/A
mL
mL
N/A
Method: SM 9222B
Preparation: N/A
N/A
No Equipment Assigned420-57832-1
Analyte QualLimitRPDResultSample Result/Qual
52006300 19 20Coliform, Total
EnviroTest Laboratories, Inc.
Calculations are performed before rounding to avoid round-off errors in calculated results.
Page 15 of 19
Quality Control Results
Job Number: 420-57832-1Client: Alpha Analytical
Sdg Number: L1213994
WaterClient Matrix:
1.0Dilution:
Date Analyzed:
Lab Sample ID:
08/08/2012 0900
Method Blank - Batch: 420-58468
Date Prepared:
Instrument ID:
Lab File ID:
Initial Weight/Volume:
Final Weight/Volume:
Injection Volume:
Analysis Batch: 420-58468
Prep Batch: N/A
N/A
Units: CFU/100mL
Method: SM 9222D
Preparation: N/A
N/A
No Equipment AssignedMB 420-58468/1
Analyte Result Qual RL
<1.00 1.00Coliform, Fecal
CFU/100mLUnits:
Water
Dilution: 100
Date Analyzed:
Duplicate - Batch: 420-58468
Lab Sample ID:
Client Matrix:
Date Prepared:
08/08/2012 0900
Instrument ID:
Lab File ID:
Initial Weight/Volume:
Final Weight/Volume:
Injection Volume:
Analysis Batch: 420-58468
Prep Batch: N/A
mL
mL
N/A
Method: SM 9222D
Preparation: N/A
N/A
No Equipment Assigned420-57832-1
Analyte QualLimitRPDResultSample Result/Qual
37004800 26 20 FColiform, Fecal
EnviroTest Laboratories, Inc.
Calculations are performed before rounding to avoid round-off errors in calculated results.
Page 16 of 19
Quality Control Results
Job Number: 420-57832-1Client: Alpha Analytical
Sdg Number: L1213994
WaterClient Matrix:
1.0Dilution:
Date Analyzed:
Lab Sample ID:
08/08/2012 1200
Method Blank - Batch: 420-58473
Date Prepared:
Instrument ID:
Lab File ID:
Initial Weight/Volume:
Final Weight/Volume:
Analysis Batch: 420-58473
Prep Batch: N/A
N/A
Units: mg/L
Method: SM5210B*M
Preparation: N/A
N/A
No Equipment AssignedMB 420-58473/1
Analyte Result Qual RL
<2.00 2.00Biochemical Oxygen Demand
mg/LUnits:
Water
Dilution: 4.0
Date Analyzed:
Duplicate - Batch: 420-58473
Lab Sample ID:
Client Matrix:
Date Prepared:
08/08/2012 1200
Instrument ID:
Lab File ID:
Initial Weight/Volume:
Final Weight/Volume:
Analysis Batch: 420-58473
Prep Batch: N/A
N/A
Method: SM5210B*M
Preparation: N/A
N/A
No Equipment Assigned420-57832-6
Analyte QualLimitRPDResultSample Result/Qual
20.2022.1 9 20Biochemical Oxygen Demand
EnviroTest Laboratories, Inc.
Calculations are performed before rounding to avoid round-off errors in calculated results.
Page 17 of 19
LOGIN SAMPLE RECEIPT CHECK LIST
Client: Alpha Analytical Job Number: 420-57832-1
Sdg Number: L1213994
Question T/F/NA Comment
Login Number: 57832
Samples were collected by ETL employee as per SOP-SAM-1 NA
The cooler's custody seal, if present, is intact. NA
The cooler or samples do not appear to have been compromised or tampered with. True
Samples were received on ice. True
Cooler Temperature is recorded. 5.4 CTrue
Cooler Temp. is within method specified range.(0-6 C PW, 0-8 C NPW, or BAC <10
C
True
If false, was sample received on ice within 6 hours of collection. NA
Based on above criteria cooler temperature is acceptable. True
COC is present. True
COC is filled out in ink and legible. True
COC is filled out with all pertinent information. True
There are no discrepancies between the sample IDs on the containers and the
COC.
True
Samples are received within Holding Time. True
Sample containers have legible labels. True
Containers are not broken or leaking. True
Sample collection date/times are provided. True
Appropriate sample containers are used. True
Sample bottles are completely filled. True
There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs True
VOA sample vials do not have headspace or bubble is <6mm (1/4") in diameter. NA
If necessary, staff have been informed of any short hold time or quick TAT needs True
Multiphasic samples are not present. True
Samples do not require splitting or compositing. True
EnviroTest Laboratories, Inc.Page 19 of 19