Istruzioni per l’installazione Installation instructions GB · Per accedere alla scheda MICRO SD...

20
Istruzioni per l’installazione 24845600 - 05_2008 IT GB Installation instructions

Transcript of Istruzioni per l’installazione Installation instructions GB · Per accedere alla scheda MICRO SD...

  • Istruzioni per l’installazione

    24845600 - 05_2008

    IT

    GBInstallation instructions

  • 2

    Manuale per l’Utente

    203 31

    108

    1

    2

    AABB

  • 3

    Manuale per l’Utente

    3

    4

  • 4

    Manuale per l’Utente

    5

    ��

    ��

    AL

    B

    + –

    MM

    6

    M1M1M2M2

    SW4SW4

  • 5

    Manuale per l’Utente

    OPEN

    LOCK

    ��

    OPEN

    LOCK

    MICRO SDMICRO SD

    ��

    7 8

    RESET

    9

  • 6

    Istruzioni per l’installazione

    IT

  • 7

    Istruzioni per l’installazione

    IT

    Mitho è l’innovativo videocitofono a colori touch screen, pensato per gli impianti sistema a due fi li X1 e 300 (alimentazione separata). L’audio viva voce e la cornetta integrata permettono una comunicazione semplice e immediata.

    CARATTERISTICHE TECNICHE

    • Display 16:9 wide screen 4.3”, 480x272 pixel, touch screen.

    • Alimentazione: 14÷24 V DC locale (12÷16 V AC locale).• Assorbimento: 0.75 A (1.5 A di picco) 12 V AC, 0.5 A (1.1 A di picco) 16 V AC, 0.31 A (0,81 A di picco) 18 V DC 0.23 A (0,58 A di picco) 24 V DC.• Dimensioni: 203 x 108 x 31 mm.

    ISTRUZIONI PER IL MONTAGGIO

    AVVERTENZE PER L’INSTALLAZIONE• Non esporre lo schermo LCD alla luce diretta del

    sole.• Si raccomanda di installare il videoterminale in un

    ambiente asciutto lontano da stillicidio o spruzzi d’acqua.

    InstallazioneSganciare l’apparecchio dal supporto metallico, fa-cendolo scorrere su di esso dopo aver premuto il pulsante plastico. Fissare il supporto metallico alla scatola d’incasso ton-da Ø 60 mm (fi g. 2A) oppure alla scatola rettangolare 503 (fi g. 2B), utilizzando le viti in dotazione e rispet-tando l’indicazione ALTO. La scatola deve essere installata ad un’altezza ade-guata all’utente. Su pareti non perfettamente piane evitare il serrag-gio eccessivo delle viti.Eff ettuati i collegamenti (fi g. 3) (vedere “ISTRUZIO-NI PER IL COLLEGAMENTO”) agganciare il video-terminale al supporto metallico come indicato in fi gura 4.Per sganciare l’apparecchio dal supporto metallico

    MITHO Videocitofono a colori Touch Screen premere il gancio plastico e sollevare il terminale come indicato in fi gura 5.Per accedere alla scheda MICRO SD procedere come indicato in fi gura 7/8.ATTENZIONE. Prima di inserire o togliere la MI-CRO SD, togliere l’alimentazione al videotermi-nale rimuovendo le morsettiere M1 e M2.

    ISTRUZIONI PER IL COLLEGAMENTO

    Il videoterminale può essere alimentato sia in cor-rente continua che alternata.

    Funzione dei morsetti (fig. 6)

    Morsettiera M1

    BUS X1 B

    +ingresso chiamata dal pianerottolo

    ingresso allarme(attivo verso massa)

    AL

    Morsettiera M2

    BUS MultiMaster MM

    14÷24 V DC 12÷16 V ACalimentazione locale

    Per permettere il funzionamento sincronizzato di più Videocitofoni Mitho all’interno della stessa abitazione (funzione opzionale), è necessario che essi siano connessi fra loro mediante il bus Mul-tiMaster.

    ATTENZIONE. Una volta eseguiti i cablaggi rein-serire attentamente le morsettiere come indica-to in fi gura 6.

  • 8

    Istruzioni per l’installazione

    IT

    Funzione del pulsante RESETOgni volta che anomalie di funzionamento, inter-venti e altre ragioni tecniche richiedono il reset dell’apparecchio, premere leggermente il pulsante collocato all’interno dell’apertura al di sotto della scocca del dispositivo (vedi figura 9), utilizzando il pennino in dotazione; rilasciare il pulsante appe-na lo schermo si oscura e attendere che riappaia il menù principale prima di riprendere l’uso normale dell’apparecchio. NOTA.Questa operazione NON comporta la cancel-lazione di eventuali programmi che saranno ripristi-nati, assieme agli altri dati, al riavvio dell’apparec-chio.

    Funzione del ponticello SW4(Resistenza di chiusura)L’apparecchio dispone di un ponticello SW4 (fi g. 6), per l’impedenza di chiusura di fi ne linea. Togliere il ponticello se la linea prosegue verso altri derivati in-terni videocitofonici.

    PROGRAMMAZIONE

    Programmazione della chiamata da posto esterno in impianti X1/300:Per la programmazione della chiamata in impianti X1/300 riferirsi al paragrafo “Programmazione de-rivati interni” presente nelle istruzioni relative ai posti esterni X1 oppure nell’alimentatore XA/300LR-XA/301LR.Per la programmazione del videocitofono a colori touch screen MITHO procedere come di seguito:a. Dalla schermata principale del terminale Mitho

    selezionare l’icona “setup”, ⇒ “tecnico”, ⇒ e premere il pulsante “program. manuale”.

    b. Premere sul posto esterno il tasto di chiama-ta che si vuole associare al terminale Mitho.Si possono associare fi no a 3 chiamate; per la programmazione della 2a e 3a chiamata dal posto esterno è suffi ciente premere i tasti corrispondenti successivamente al primo pulsante di chiamata.

    NOTA. Non uscire dalla programmazione del de-rivato interno prima di avere associato tutte le chiamate desiderate. Per la programmazione delle chiamate interco-municanti vedere le istruzioni allegate al selettore VSE/301.

    Programmazione del dispositivo mediante softwareÉ possibile programmare l’impianto mediante i sof-tware PCS/300 (consultare le relative istruzioni).Per l’invio del “serial number” procedere come se-gue:dalla schermata principale del terminale Mitho sele-zionare l’icona “setup”, ⇒ “tecnico”, ⇒ e premere il pulsante “invio SN”.

    Attivazione della funzione “building” Qualora l’im-pianto preveda la presenza di un centralino di porti-neria, sarà possibile attivare sul terminale la funzione building seguendo la seguente procedura:Dalla schermata principale del terminale Mitho sele-zionare l’icona “setup”, ⇒ “tecnico”, ⇒ e premere il pulsante “building”.Con la funzione “building” attiva, verrà visualizzato sulla schermata principale del terminale Mitho un pulsante “panico” , premendo il quale viene invia-to al centralino una chiamata riportante il numero dell’interno chiamante; tale chiamata è prioritaria sulle altre; inoltre premendo il pulsante verrà attivata la modalità “privacy” che, oltre ad escludere le suonerie del terminale, provvederà ad informare il centralino di portineria che l’utente non vuole essere disturbato.

    Sincronizzazione dei terminaliDalla schermata principale del terminale Mitho sele-zionare l’icona “setup”, ⇒ “tecnico”, ⇒ e premere il pulsante “MM”.Attivando la funzione “MM” verranno sincronizza-te, le funzioni orologio, data, segreteria e privacy tra i terminali connessi mediante bus MM.

    Salvare la confi gurazione del terminaleDalla schermata principale del terminale Mitho sele-zionare l’icona “setup”, ⇒ “tecnico”, ⇒ e premere il pulsante “ ”.Questa operazione permette di salvare la confi-gurazione del terminale nella scheda di memoria removibile.L’operazione è di notevole importanza nei casi in cui si debba aggiornare il firmware del terminale o nel caso in cui si voglia trasferire una configurazio-ne da un terminale ad un altro con stesso codice chiamata.

  • 9

    Istruzioni per l’installazione

    IT

    Impostare lo standard del segnale video del-l’impianto.Dalla schermata principale del terminale Mitho se-lezionare l’icona “setup”, ⇒ “tecnico”, ⇒ e pre-mere il pulsante “PAL -> NTSC” per passare da PAL a NTSC, premere il pulsante “NTSC -> PAL” per passare da NTSC a PAL.PAL Standard video 50 Hz (paesi Europei)NTSC Standard video 60 Hz

    Per tutte le altre informazioni consultare il manuale d’uso del videoterminale.

    SMALTIMENTOAssicurarsi che il materiale d’imballaggio non ven-ga disperso nell’ambiente, ma smaltito seguendo le norme vigenti nel paese di utilizzo del prodotto.Alla fi ne del ciclo di vita dell’apparecchio evitare che lo stesso venga disperso nell’ambiente.Lo smaltimento dell’apparecchiatura deve essere ef-fettuato rispettando le norme vigenti e privilegian-do il riciclaggio delle sue parti costituenti.Sui componenti, per cui è previsto lo smaltimento con riciclaggio, sono riportati il simbolo e la sigla del materiale.

  • 10

    Istruzioni per l’installazione

    IT

  • 11

    Installation instructions

    GB

    Mitho is the innovative colour touch screen video entry control, designed for two-wire X1 and 300 sys-tems (separate power supply). The hands-free audio and the integrated receiver allow simple, immediate communications.

    TECHNICAL FEATURES

    • 16:9 wide screen 4.3” 480x272 pixel touch screen display

    • Power supply: 14÷24 V DC local (12÷16 V AC local).• Absorption: 0.75 A (1.5 A peak) 12 V AC, 0.5 A (1.1 A peak) 16 V AC, 0.31 A (0.81 A peak) 18 V DC 0.23 A (0.58 A peak) 24 V DC• Dimensions: 203 x 108 x 31 mm.

    ASSEMBLY INSTRUCTIONS

    INSTALLATION TIPS• Do not expose the LCD screen to direct sun light.• We recommend installing the video terminal in

    a dry area protected from seepage or splashes of water.

    InstallationRemove the unit from the metallic support by sli-ding it after pressing the plastic button. Fasten the metallic support to the round built-in box of¯ 60 mm (fi g. 2A) or to the rectangular box 503 (fi g. 2B), using the screws provided and complying with the UP indication. The recessed box must be fi tted at a suitable height in relation to the user. Avoid excessive tightening of screws on walls that are not perfectly fl at.After making the connections (fi g. 3) (see “CONNEC-TION INSTRUCTIONS”), hook the video terminal to the metal support as illustrated in fi gure 4.To release the appliance from the metal support, press the plastic hook and lift the terminal as illus-trated in fi gure 5.To access the MICRO SD card proceed as illustrated in fi gure 7/8.

    MITHO Colour touch screen video entry controlATTENTION. Before inserting or removing the MICRO SD, cut off the power supply to the video terminal by removing the terminal boards M1 and M2.

    CONNECTION INSTRUCTIONS

    The video terminal can be powered by both direct and alternating current.

    Function of the terminals (fi g. 6)

    Terminal block M1

    BUS X1 B

    +ground fl oor call input

    alarm input (active towards earth)

    AL

    Terminal block M2

    Multimaster BUS MM

    14÷24 V DC 12÷16 V AClocal power supply

    To synchronize the operation of more Video entry panel Mitho in the same house (optional feature), they must be connected to one another by Mul-tiMaster bus.

    ATTENTION. Once wiring is complete, carefully re-insert the terminal boards as shown in fi gure 6.

    Function of the RESET buttonAny time that operating anomalies, servicing or other technical reasons require the unit to be re-set, press lightly on the button located inside the opening under the body of the device (see fi gure 9), using the pen provided. Release the button as soon as the screen goes dark and wait for the main

  • 12

    Installation instructions

    GB

    menu to reappear before resuming normal use of the unit.NOTE. This operation does NOT delete any pro-grammes, which will be restored, along with other data, when the unit is restarted.

    Function of the jumper SW4(Closure resistance)The appliance is equipped with an SW4 jumper (fi g. 6), for end of line closure impedance. Remove the jumper if the line continues towards other video entry control receivers.

    PROGRAMMING

    Entry panel call programming in X1/300 sys-tems:To programme calls in X1/300 systems, refer to the paragraph “Programming internal extensions” in-cluded in the instructions for the X1 entry panels or in the power supplier XA/300LR-XA/301LR.To programme the MITHO touch screen colour vi-deo entry control, proceed as follows:a. Select the “Setup”, ⇒ “Service”, ⇒ icon from

    the main screen of the Mitho terminal and press the “manual prog.” button.

    b. On the entry panel, press the call key that you wish to associate with the Mitho terminal.

    It is possible to associate up to 3 calls; to program-me the 2nd and 3rd call from the entry panel, just press the keys corresponding successively to the fi rst call button.

    NOTE. Do not exit receiver programming before associating all the desired calls. To programme intercom calls, see the instructions provided with selector VSE/301.

    Programming the device using softwareThe system can be programmed using PCS/300 software (see the relative instructions).To send the “serial number”, proceed as follows:select the “Setup”, ⇒ “Service“, ⇒ icon from the main screen of the Mitho terminal and press the “send SN” button.

    Activation of the “building” function When the system envisages the presence of a porter switchboard, it will be possible to activate the build-ing function on the terminal by following the follow-

    ing procedure:Select the “setup”, ⇒ “service”, ⇒ icon from the main screen of the Mitho terminal and press the “building” button.With the “building” function active, a “panic” but-ton will be shown on the main screen of the Mitho terminal. By pressing this button, a call is sent to the switchboard showing the calling apartment number. This call takes priority over all others. More-over, by pressing the button, “privacy” mode is activated. In addition to excluding the terminal ring-tones, it also informs the porter switchboard that the user does not wish to be disturbed.

    Terminals synchronizationSelect the “Setup”, ⇒ “Service”, ⇒ icon from the main screen of the Mitho terminal and press the “MM” button.Activating the “MM” functions you can synchro-nize: clock, date, secretarial and privacy, between terminals connected through bus MM.

    Save the terminal confi gurationSelect the “Setup”, ⇒ “Service”, ⇒ icon from the main screen of the Mitho terminal and press the “

    ” button. This operation allows you to save the configuration of the terminal in the removable memory card.The operation is of considerable importance in cases where we should update the firmware of ter-minal or in case you want to transfer a configuration from a terminal to another with the same code call.

    Setting the standard video signalSelect the “Setup”, ⇒ “Service”, ⇒ icon from the main screen of the Mitho terminal and press the button “PAL -> NTSC” to switch from PAL to NTSC, press the button “NTSC -> PAL” to switch from NTSC to PAL

    PAL Standard video 50 Hz (European countries)NTSC Standard video 60 Hz

    For any other information refer to the video termi-nal’s user manual.

  • 13

    Installation instructions

    GB

    DISPOSALDo not litter the environment with packaging ma-terial: make sure it is disposed of according to the regulations in force in the country where the prod-uct is used.When the equipment reaches the end of its life cy-cle, avoid discarding in the environment.The equipment must be disposed of in compliance with current regulations, recycling its component parts wherever possible.Components that qualify as recyclable waste feature the relevant symbol and material acronym.

  • 14

    Manuale per l’Utente

    MITHOM1

    M2

    AL

    B

    MM

    – +

    CP

    OPHERA(OPHERA/B)

    SW1

    M1

    B

    -+

    AL

    BUS

    LOCAL

    SW2

    SW2

    SW4SW3

    XDV/304

    3 4IN

    SW4

    SW0

    VAS/100MH

    – +18V

    230VPRI

    SEC

    + 18V –

    230V

    230V 50Hz 18V 10VA

    MITHOM1

    M2

    AL

    B

    MM

    – +

    SW4

    VAS/100MH

    – +18V

    230VPRI

    SEC

    + 18V –

    230V

    230V 50Hz 18V 10VA

    1 2

    OU

    T

    B SE 300V14 B

    3

    2

    1SE 300V14IMPIANTO VIDEOCITOFONICO PLURIFA-MILIARE (SISTEMA 300).

    MULTIPLE APARTMENT VIDEO ENTRY CONTROL SYSTEM (SYSTEM 300).

    SE 300V14-A

  • 15

    Manuale per l’Utente

    C

    XA/301LR

    B

    +-

    A

    L

    CNV

    +-B

    CNV

    XAV/300

    CNTC

    B

    B

    A

    +XUP–XUP

    CNS

    CNT

    –XUP+XUP–XUP+XUP

    ICP/LR

    L+

    12V

    1

    HPV/1+HAV/200+HIA/300+ICP/LR+…KHPS (…KHPD)+HTS+HEP/306(...HEP/312D)

    CN1

    CN3

    CN2

    HIA/300

    A

    +

    +

    V OUT

    V IN

    34

    CB

    CBO

    0 1 2 3 4

    SW3

    RV

    S

    BA

    NG

    CN

    HAV/20056

    111214

    SW1

    T C

    V−V+VS

    521

    120

    120

    2x56

    B SE 300V14-A

    2x56B

    +V-V-

    CBI

    HEP/306(HEP/312D)

    CBO

    SE 300V14-B

  • 16

    Manuale per l’Utente

    MITHOM1

    M2

    AL

    B

    MM

    – +

    CP

    OPHERA(OPHERA/B)

    SW1

    M1

    B

    -+

    AL

    BUS

    LOCAL

    SW2

    SW2

    SW4SW3

    XDV/304

    3 4IN

    SW4

    SW0

    VAS/100MH

    – +18V

    230VPRI

    SEC

    + 18V –

    230V

    230V 50Hz 18V 10VA

    MITHOM1

    M2

    AL

    B

    MM

    – +

    SW4

    VAS/100MH

    – +18V

    230VPRI

    SEC

    + 18V –

    230V

    230V 50Hz 18V 10VA

    1 2

    OU

    T

    B SE 301V04 B

    3

    2

    1SE 301V04-ASE 301V04IMPIANTO VIDEOCITOFONICO PLURIFA-MILIARE (SISTEMA X1).

    MULTIPLE APARTMENT VIDEO ENTRY CONTROL SYSTEM (SYSTEM X1).

  • 17

    Manuale per l’Utente

    B

    VA/301

    B OUTCN1M2

    G

    M1+-

    B IN

    12V

    HEV/301+…HEP/306(…HEP/312D)

    CBI CN1

    HEP/306(HEP/312D)

    CN3

    CN5CBO

    CN4

    SW1 SW2

    B IN

    B OUT

    SE 301V04-A

    NM

    SE 301V04-B

  • 18

    Manuale per l’Utente

    MITHOM1

    M2

    AL

    B

    MM

    – +

    XDV/304

    SW4

    VAS/100MH

    – +18V

    230VPRI

    SEC

    + 18V –

    230V

    230V 50Hz 18V 10VA

    B SE 301V05 B

    MITHOM1

    M2

    AL

    B

    MM

    – +

    SW4

    VAS/100MH

    – +18V

    230VPRI

    SEC

    + 18V –

    230V

    230V 50Hz 18V 10VA

    MITHOM1

    M2

    AL

    B

    MM

    – +

    SW4

    VAS/100MH

    – +18V

    230VPRI

    SEC

    + 18V –

    230V

    230V 50Hz 18V 10VA

    SW2

    SW4SW3

    SW0

    1 2

    OU

    T

    3 4IN

    1A

    1B

    1C

    SE 301V05-ASE 301V05IMPIANTO VIDEOCITOFONICO MONO-FAMILIARE (SISTEMA X1).

    SINGLE APARTMENT VIDEO ENTRY CON-TROL SYSTEM (SYSTEM X1).

  • 19

    Manuale per l’Utente

    B

    VA/301

    B OUTCN1M2

    G

    M1+-

    B IN

    12V

    HEV/301

    CN1

    CN3

    CN5

    CN4

    SW1 SW2

    B IN

    B OUT

    SE 301V05-A

    NM

    SE 301V05-B

  • BPT S.p.A.Via Roma, 4130020 Cinto Caomaggiore/VE/Italyhttp: www.bpt.ite-mail: [email protected]