ISO25 - Pentair Southern · PDF fileiso25 pmp centrifugal pump performance data 60 prrm ......
Transcript of ISO25 - Pentair Southern · PDF fileiso25 pmp centrifugal pump performance data 60 prrm ......
ISO2858END SUCTION PUMPS60Hz PERFORMANCECENTRIFUGAL PUMP PERFORMANCE DATA
SELECTION CHART
1780/3550 R.P.M.
Flow Rate (litres/sec)3 4 5 6 8 10 20 30 40 50 70 100 150 200
10 20 30 50 100 150 250 500Flow Rate (m3/hour)
Tota
l Hea
d (m
) 10080
6050
40
30
20
10
200
150
IGPM 50 100 150 250 500 1000 1500 2500
USGPM 50 100 150 250 500 1000 1500 2500
Tota
l Hea
d (fe
et)
200
100
50
40
300
400
500
6003550 R.P.M.(Nominal Speed)
50x32-160
50x32-200
65x40-250
65x50-160
65x40-200
80x50-250
80x50-200
80x65-160
100x65-250
100x65-200
100x80-160
125x80-250
125x80-200
150x125
-250*
125x100-250
125x100-200
Flow Rate (litres/sec)
Tota
l Hea
d (m
)
3 4 5 6 8 10 20 30 40 50 70 100 150 200 300
10 20 30 50 100 150 250 500 1,000
10080
605040
30
20
108
65
200
150
Flow Rate (m3/hour)
IGPM 50 100 150 250 500 1000 1500 2500USGPM 50 100 150 250 500 1000 1500 2500 5000
Tota
l Hea
d (fe
et)
200
100
504030
20
15
300
4005006001780 R.P.M.
(Nominal Speed)
50x32-160
50x32-200
65x40-315
65x40-250 250x200-315
65x50-160
65x40-200
80x50-315
80x50-250
80x50-200
80x65-160
100x65-315
100x65-250
100x65-200
100x80-160
125x80-250
125x80-200
125x100-400
150x125-400
150x125-315
150x125-250
200x150-400
150x 125 -500 200x150
-500
125x100-315
125x80-400
125x100-500
125x100 -250
125x 100 -200
125x 80 -315 200x150
-315
* ISO-PRO Pumps (ISO5199 Standard) required to operate this model (150x125-250) at 2 pole speed.
ISO2858END SUCTION PUMPS60Hz PERFORMANCECENTRIFUGAL PUMP PERFORMANCE DATA
Performance to AS2417 Grade 2 for clean, cold water only.
Performance to AS2417 Grade 2 for clean, cold water only.
VOLUMETRIC FLOW RATE
TOTA
L H
EAD
- M
ETR
ES
TOTA
L H
EAD
- FE
ET
VOLUMETRIC FLOW RATE
TOTA
L H
EAD
- M
ETR
ES
TOTA
L H
EAD
- FE
ET
MODEL
50x32-160
A division of tyco Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
50x32-160
0 .5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 60 2 4 6 8 10 12 14 16 18 20
0 10 20 30 40 50 60 700 10 20 30 40 50 60 70 80 90
VOLUMETRIC FLOWRATE
l/secm/hr
igpmusgpm
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1517.52022.52527.53032.53537.54042.54547.55052.55557.5SPEED: 1740 R.P.M.
INLET DIA.: 50 mm
DISCH DIA.: 32 mm
No. 1 SHAFT MODULE
MAXIMUM POWER 1.07 kW
2
4
6
8NPSHR
metres
DATA FOR CLEAN COLD WATER ONLY
PUMP MODEL
50x32-160
PUMP PERFORMANCE TO AS2417 GRADE 2
CURVE No.
DATE 31-03-10 ISSUE 1
SEA604
182
173
164
155
146IMPELLER DIA. - mm
.75 kW.55 kW
.37 kW
30% 40%
40%
50%
50%
54%
54%
56%
56%
58%
58%
59%
182mm
NPSHR 146mm
TOTAL
HEAD
~
METRES
TOTAL
HEAD
~
FEET
0 1 2 3 4 5 6 7 8 9 10 11 120 4 8 12 16 20 24 28 32 36 40
0 20 40 60 80 100 120 1400 20 40 60 80 100 120 140 160
VOLUMETRIC FLOWRATE
l/secm/hr
igpmusgpm
25
30
35
40
45
50
55
60
65
70
75
80
100
120
140
160
180
200
220
240SPEED: 3540 R.P.M.INLET DIA.: 50 mm
DISCH DIA.: 32 mm
No. 1 SHAFT MODULE
MAXIMUM POWER 8.3 kW
2468NPSHR
metres
DATA FOR CLEAN COLD WATER ONLY
PUMP MODEL
50x32-160
PUMP PERFORMANCE TO AS2417 GRADE 2
CURVE No.
DATE 08-04-10 ISSUE 1
SEA602
182
173
164
155
146IMPELLER DIA. - mm
7.5 kW
5.5 kW4 kW
3 kW2.2 kW
30% 40%50% 55%
55%
60%
60%
62%
62%
63%
63%
64%
64%
182mmNPSHR 146mm
TOTAL
HEAD
~
METRES
TOTAL
HEAD
~
FEET
A division of tyco Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
50x32-160
0 .5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 60 2 4 6 8 10 12 14 16 18 20
0 10 20 30 40 50 60 700 10 20 30 40 50 60 70 80 90
VOLUMETRIC FLOWRATE
l/secm/hr
igpmusgpm
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1517.52022.52527.53032.53537.54042.54547.55052.55557.5SPEED: 1740 R.P.M.
INLET DIA.: 50 mm
DISCH DIA.: 32 mm
No. 1 SHAFT MODULE
MAXIMUM POWER 1.07 kW
2
4
6
8NPSHR
metres
DATA FOR CLEAN COLD WATER ONLY
PUMP MODEL
50x32-160
PUMP PERFORMANCE TO AS2417 GRADE 2
CURVE No.
DATE 31-03-10 ISSUE 1
SEA604
182
173
164
155
146IMPELLER DIA. - mm
.75 kW.55 kW
.37 kW
30% 40%
40%
50%
50%
54%
54%
56%
56%
58%
58%
59%
182mm
NPSHR 146mm
TOTAL
HEAD
~
METRES
TOTAL
HEAD
~
FEET
0 1 2 3 4 5 6 7 8 9 10 11 120 4 8 12 16 20 24 28 32 36 40
0 20 40 60 80 100 120 1400 20 40 60 80 100 120 140 160
VOLUMETRIC FLOWRATE
l/secm/hr
igpmusgpm
25
30
35
40
45
50
55
60
65
70
75
80
100
120
140
160
180
200
220
240SPEED: 3540 R.P.M.INLET DIA.: 50 mm
DISCH DIA.: 32 mm
No. 1 SHAFT MODULE
MAXIMUM POWER 8.3 kW
2468NPSHR
metres
DATA FOR CLEAN COLD WATER ONLY
PUMP MODEL
50x32-160
PUMP PERFORMANCE TO AS2417 GRADE 2
CURVE No.
DATE 08-04-10 ISSUE 1
SEA602
182
173
164
155
146IMPELLER DIA. - mm
7.5 kW
5.5 kW4 kW
3 kW2.2 kW
30% 40%50% 55%
55%
60%
60%
62%
62%
63%
63%
64%
64%
182mmNPSHR 146mm
TOTAL
HEAD
~
METRES
TOTAL
HEAD
~
FEET
CENTRIFUGAL PUMP PERFORMANCE DATA
ISO2858END SUCTION PUMPS60Hz PERFORMANCE
Performance to AS2417 Grade 2 for clean, cold water only.
Performance to AS2417 Grade 2 for clean, cold water only.
VOLUMETRIC FLOW RATE
TOTA
L H
EAD
- M
ETR
ES
TOTA
L H
EAD
- FE
ET
VOLUMETRIC FLOW RATE
TOTA
L H
EAD
- M
ETR
ES
TOTA
L H
EAD
- FE
ET
MODEL
50x32-200
A division of tyco Flow Control Pacific Pty Ltd A.B.N. 83 000 922 690
50x32-200
0 .5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.50 2 4 6 8 10 12 14 16 18 20 22 24
0 10 20 30 40 50 60 70 80 900 10 20 30 40 50 60 70 80 90 100
VOLUMETRIC FLOWRATE
l/secm/hr
igpmusgpm
10
12.5
15
17.5
20
22.5
25
27.5
30
30
40
50
60
70
80
90
SPEED: 1740 R.P.M.INLET DIA.: 50 mm
DISCH DIA.: 32 mm
No. 1 SHAFT MODULE
MAXIMUM POWER 2.16 kW
2468NPSHR
metres
DATA FOR CLEAN COLD WATER ONLY
PUMP MODEL
50x32-200
PUMP PERFORMANCE TO AS2417 GRADE 2
CURVE No.
DATE 31-03-10 ISSUE 1
SFA604
228
217
205
194
182IMPELLER DIA. - mm
1.5 kW
1.1 kW
.75 kW
30% 40%45%
50%
50%
52%
52%
53%
53%
228mm
NPSHR
182mm
TOTAL
HEAD
~
METRES
TOTAL
HEAD
~
FEET
0 1 2 3 4 5 6 7 8 9 10 11 120 4 8 12 16 20 24 28 32 36 40
0 20 40 60 80 100 120 1400 20 40 60 80 100 120 140 160 180
VOLUMETRIC FLOWRATE
l/secm/hr
igpmusgpm
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
160
180
200
220
240
260
280
300
320
340
360
380SPEED: 3540 R.P.M.INLET DIA.: 50 mm