IP Pricelist 09
-
Upload
babaisandip -
Category
Documents
-
view
84 -
download
6
description
Transcript of IP Pricelist 09
Contents
Terms & Conditions
o Prices are in Indian Rupees.
o All prices are on Maximum Retail Price (MRP) basis inclusive of Excise Duty and VAT/Sales Tax. Freight / Delivery charges if paid by Havells shall be on behalf of customer only.
o However Discount Structure is exclusive of VAT/Taxes.
o Goods are despatched by us on Purchaser’s risk. All claims for loss, damage or shortage will be filed by the Purchasers directly with the carriers.
o Disputes, if any are subject to Delhi jurisdiction only.
o This Price List supersedes all our previous Price Lists.
o Prices are subject to change without notice.
o Company reserves the right to issue amendments, which may arise due to any errors in the price list.
Industrial Switchgear Page Nos.
- Titania Air Circuit Breaker IP-2 to IP-7
- Loadline Moulded Case Circuit Breaker IP-8 to IP-13
- Loadline Digital Moulded Case Circuit Breaker IP-14
- Load Bank MCCB Panel Boards IP-15 to IP-16
- Powerline Contactors & Accessories IP-17 to IP-18
- Powerline Thermal Overload Relay IP-19
- Powerline Motor Starters IP-20
- Powerline Line Submersible Starter IP-21
- Euroload Changeover Switch IP-22
- Euroload By-Pass Changeover Switch IP-22
- Instaline Automatic Transfer Switch + Phase Corrector ATS IP-23
- Euroload Switch Disconnector IP-24
- Kompact Switch Disconnector Fuse IP-25 to IP-26
- High Breaking Capacity Fuse Links, Camlock Fuse Holders & Fuse Bases + Kit Kat IP-27 to IP-29
Conventional Switchgear
- General Purpose Load Changeover Switch + Busbar Chamber System IP-30
- General Purpose Fuse Switch & Switch Fuse IP-31
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-2
Air Circuit Breaker(Conforms to IEC:60947 - 2 / IS: 13947 - 2)
ACB with Microprocessor Release IPR E3 Pole
ACB with Microprocessor Release IPR 13 Pole
ACB with Microprocessor Release IPR 14 Pole
Current Breaking Ordering Code LP in Rs. Ordering Code LP in Rs. Rating Capacity MANUAL ELECTRICAL
ACB with Microprocessor Release IPR E4 Pole
(A) 415V Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout (KA)
630 50 IHATE1E060**# IHATE2E060**# 43,050 76,365 IHATE4E06$**# IHATE5E06$**# 68,675 1,01,990 800 50 IHATE1E080**# IHATE2E080**# 44,590 77,490 IHATE4E08$**# IHATE5E08$**# 70,215 1,03,115 1000 50 IHATE1E100**# IHATE2E100**# 48,175 81,180 IHATE4E10$**# IHATE5E10$**# 73,800 1,06,805 1250 50 IHATE1E120**# IHATE2E120**# 65,600 1,00,965 IHATE4E12$**# IHATE5E12$**# 91,225 1,26,590 1600 50 IHATE1E160**# IHATE2E160**# 69,700 1,08,650 IHATE4E16$**# IHATE5E16$**# 95,325 1,34,275 2000 50 IHATE1E200**# IHATE2E200**# 78,925 1,31,200 IHATE4E20$**# IHATE5E20$**# 1,04,550 1,56,825 2500 75 IHATH1E250**# IHATH2E250**# 94,300 1,57,395 IHATH4E25$**# IHATH5E25$**# 1,19,925 1,72,880 3200 100 IHATV1E320**# IHATV2E320**# 1,38,375 2,06,960 IHATV4E32$**# IHATV5E32$**# 1,64,000 2,23,415 4000 100 IHATV1E400**# IHATV2E400**# 2,07,050 2,48,345 IHATV4E40$**# IHATV5E40$**# 2,32,675 2,67,040
Current Breaking Ordering Code LP in Rs. Ordering Code LP in Rs. Rating Capacity MANUAL ELECTRICAL
(A) 415V Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout (KA)
630 50 IHAFE1E060**# IHAFE2E060**# 57,400 96,095 IHAFE4E06$**# IHAFE5E06$**# 83,025 1,21,720 800 50 IHAFE1E080**# IHAFE2E080**# 59,450 97,120 IHAFE4E08$**# IHAFE5E08$**# 85,075 1,22,745 1000 50 IHAFE1E100**# IHAFE2E100**# 62,525 1,02,145 IHAFE4E10$**# IHAFE5E10$**# 88,150 1,27,770 1250 50 IHAFE1E120**# IHAFE2E120**# 88,150 1,27,510 IHAFE4E12$**# IHAFE5E12$**# 1,13,775 1,53,135 1600 50 IHAFE1E160**# IHAFE2E160**# 91,740 1,37,300 IHAFE4E16$**# IHAFE5E16$**# 1,17,365 1,62,925 2000 50 IHAFE1E200**# IHAFE2E200**# 1,04,040 1,65,845 IHAFE4E20$**# IHAFE5E20$**# 1,29,665 1,91,470 2500 75 IHAFH1E250**# IHAFH2E250**# 1,20,850 1,99,170 IHAFH4E25$**# IHAFH5E25$**# 1,46,475 2,25,070 3200*** 100 IHAFV1E320**# IHAFV2E320**# 1,76,300 2,53,895 IHAFV4E32$**# IHAFV5E32$**# 2,01,925 2,72,495 4000*** 100 IHAFV1E400**# IHAFV2E400**# 2,66,500 2,95,280 IHAFV4E40$**# IHAFV5E40$**# 2,92,125 3,28,190
Current Breaking Ordering Code LP in Rs. Ordering Code LP in Rs. Rating Capacity MANUAL ELECTRICAL
(A) 415V Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout (KA)
630 50 IHATE11060**# IHATE21060**# 48,175 81,490 IHATE4106$**# IHATE5106$**# 73,800 1,07,115 800 50 IHATE11080**# IHATE21080**# 49,715 82,615 IHATE4108$**# IHATE5108$**# 75,340 1,08,240 1000 50 IHATE11100**# IHATE21100**# 53,300 86,305 IHATE4110$**# IHATE5110$**# 78,925 1,11,930 1250 50 IHATE11120**# IHATE21120**# 70,725 1,06,090 IHATE4112$**# IHATE5112$**# 96,350 1,31,715 1600 50 IHATE11160**# IHATE21160**# 74,825 1,13,775 IHATE4116$**# IHATE5116$**# 1,00,450 1,39,400 2000 50 IHATE11200**# IHATE21200**# 84,050 1,36,325 IHATE4120$**# IHATE5120$**# 1,09,675 1,61,950 2500 75 IHATH11250**# IHATH21250**# 99,425 1,62,520 IHATH4125$**# IHATH5125$**# 1,25,050 1,78,005 3200 100 IHATV11320**# IHATV21320**# 1,43,500 2,12,085 IHATV4132$**# IHATV5132$**# 1,69,125 2,28,540 4000 100 IHATV11400**# IHATV21400**# 2,12,175 2,53,470 IHATV4140$**# IHATV5140$**# 2,37,800 2,72,165
Current Breaking Ordering Code LP in Rs. Ordering Code LP in Rs. Rating Capacity MANUAL ELECTRICAL
(A) 415V Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout (KA)
630 50 IHAFE11060**# IHAFE21060**# 62,525 1,01,220 IHAFE4106$**# IHAFE5106$**# 88,150 1,26,845 800 50 IHAFE11080**# IHAFE21080**# 64,575 1,02,245 IHAFE4108$**# IHAFE5108$**# 90,200 1,27,870 1000 50 IHAFE11100**# IHAFE21100**# 67,650 1,07,270 IHAFE4110$**# IHAFE5110$**# 93,275 1,32,895 1250 50 IHAFE11120**# IHAFE21120**# 93,275 1,32,635 IHAFE4112$**# IHAFE5112$**# 1,18,900 1,58,260 1600 50 IHAFE11160**# IHAFE21160**# 96,865 1,42,425 IHAFE4116$**# IHAFE5116$**# 1,22,490 1,68,050 2000 50 IHAFE11200**# IHAFE21200**# 1,09,165 1,70,970 IHAFE4120$**# IHAFE5120$**# 1,34,790 1,96,595 2500 75 IHAFH11250**# IHAFH21250**# 1,25,975 2,04,295 IHAFH4125$**# IHAFH5125$**# 1,51,600 2,30,195 3200*** 100 IHAFV11320**# IHAFV21320**# 1,81,425 2,59,020 IHAFV4132$**# IHAFV5132$**# 2,07,050 2,77,620 4000*** 100 IHAFV11400**# IHAFV21400**# 2,71,625 3,00,405 IHAFV4140$**# IHAFV5140$**# 2,97,250 3,33,315
$ Please refer table 1 to replace $ at page-4** Please refer table 2 to replace ** at page-4# Please refer table 3 to replace # at page-4*** 4 Pole ACB’s 3200A and 4000A, 4th Pole is offerd both 100% or 50% rated neutral Pole
Note : Prices on request1. ACB range 630A to 2000A (65KA) / 75KA2. ACB range 630A to 4000A (IPR 3)
Air Circuit Breaker
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-3
Air Circuit Breaker(Conforms to IEC:60947 - 2 / IS: 13947 - 2)
ACB with Microprocessor Release IPR 23 Pole
$ Please refer table 1 to replace $ at page-4** Please refer table 2 to replace ** at page-4# Please refer table 3 to replace # at page-4*** 4 Pole ACB’s 3200A and 4000A, 4th Pole is offerd both 100% or 50% rated neutral Pole
Note : Prices on request1. ACB range 630A to 2000A (65KA) / 75KA2. ACB range 630A to 4000A (IPR 3)
ACB without Release4 Pole
Current Breaking Ordering Code LP in Rs. Ordering Code LP in Rs.
Rating Capacity MANUAL ELECTRICAL
(A) 415V Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout (KA)
630 50 IHAFE10060**# IHAFE20060**# 48,690 87,385 IHAFE4006$**# IHAFE5006$**# 74,315 1,13,010 800 50 IHAFE10080**# IHAFE20080**# 50,740 88,410 IHAFE4008$**# IHAFE5008$**# 76,365 1,14,035 1000 50 IHAFE10100**# IHAFE20100**# 53,815 93,430 IHAFE4010$**# IHAFE5010$**# 79,440 1,19,055 1250 50 IHAFE10120**# IHAFE20120**# 79,440 1,18,800 IHAFE4012$**# IHAFE5012$**# 1,05,065 1,44,425 1600 50 IHAFE10160**# IHAFE20160**# 83,025 1,28,590 IHAFE4016$**# IHAFE5016$**# 1,08,650 1,54,215 2000 50 IHAFE10200**# IHAFE20200**# 95,325 1,57,135 IHAFE4020$**# IHAFE5020$**# 1,20,950 1,82,760 2500 75 IHAFH10250**# IHAFH20250**# 1,12,135 1,90,455 IHAFH4025$**# IHAFH5025$**# 1,37,760 2,16,360 3200*** 100 IHAFV10320**# IHAFV20320**# 1,67,590 2,45,180 IHAFV4032$**# IHAFV5032$**# 1,93,215 2,63,780 4000*** 100 IHAFV10400**# IHAFV20400**# 2,57,790 2,86,565 IHAFV4040$**# IHAFV5040$**# 2,83,415 3,19,480
(A) 415V Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout (KA)
630 50 IHAFE12060**# IHAFE22060**# 69,700 1,08,395 IHAFE4206$**# IHAFE5206$**# 9,5,325 1,34,020 800 50 IHAFE12080**# IHAFE22080**# 71,750 1,09,420 IHAFE4208$**# IHAFE5208$**# 97,375 1,35,045 1000 50 IHAFE12100**# IHAFE22100**# 74,825 1,14,445 IHAFE4210$**# IHAFE5210$**# 1,00,450 1,40,070 1250 50 IHAFE12120**# IHAFE22120**# 1,00,450 1,39,810 IHAFE4212$**# IHAFE5212$**# 1,26,075 1,65,435 1600 50 IHAFE12160**# IHAFE22160**# 1,04,040 1,49,600 IHAFE4216$**# IHAFE5216$**# 1,29,665 1,75,225 2000 50 IHAFE12200**# IHAFE22200**# 1,16,340 1,78,145 IHAFE4220$**# IHAFE5220$**# 1,41,965 2,03,770 2500 75 IHAFH12250**# IHAFH22250**# 1,33,150 2,11,470 IHAFH4225$**# IHAFH5225$**# 1,58,775 2,37,370 3200*** 100 IHAFV12320**# IHAFV22320**# 1,88,600 2,66,195 IHAFV4232$**# IHAFV5232$**# 2,14,225 2,84,795 4000*** 100 IHAFV12400**# IHAFV22400**# 2,78,800 3,07,580 IHAFV4240$**# IHAFV5240$**# 3,04,425 3,40,490
ACB with Microprocessor Release IPR 24 Pole Current Breaking Ordering Code LP in Rs. Ordering Code LP in Rs.
Rating Capacity MANUAL ELECTRICAL
Current Breaking Ordering Code LP in Rs. Ordering Code LP in Rs.
Rating Capacity MANUAL ELECTRICAL
(A) 415V Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout (KA)
630 50 IHATE10060**# IHATE20060**# 34,340 67,650 IHATE4006$**# IHATE5006$**# 59,965 93,275 800 50 IHATE10080**# IHATE20080**# 35,875 68,780 IHATE4008$**# IHATE5008$**# 61,500 94,405 1000 50 IHATE10100**# IHATE20100**# 39,465 72,470 IHATE4010$**# IHATE5010$**# 65,090 98,095 1250 50 IHATE10120**# IHATE20120**# 56,890 92,250 IHATE4012$**# IHATE5012$**# 82,515 1,17,875 1600 50 IHATE10160**# IHATE20160**# 60,990 99,940 IHATE4016$**# IHATE5016$**# 86,615 1,25,565 2000 50 IHATE10200**# IHATE20200**# 70,215 1,22,490 IHATE4020$**# IHATE5020$**# 95,840 1,48,115 2500 75 IHATH10250**# IHATH20250**# 85,590 1,48,685 IHATH4025$**# IHATH5025$**# 1,11,215 1,64,165 3200 100 IHATV10320**# IHATV20320**# 1,29,665 1,98,245 IHATV4032$**# IHATV5032$**# 1,55,290 2,14,705 4000 100 IHATV10400**# IHATV20400**# 1,98,340 2,39,630 IHATV4040$**# IHATV5040$**# 2,23,965 2,58,330
ACB without Release3 Pole
Air Circuit Breaker
Current Breaking Ordering Code LP in Rs. Ordering Code LP in Rs. Rating Capacity MANUAL ELECTRICAL
(A) 415V Fixed Drawout Fixed Drawout Fixed Drawout Fixed Drawout (KA)
630 50 IHATE12060**# IHATE22060**# 53,300 86,615 IHATE4206$**# IHATE5206$**# 78,925 1,12,240 800 50 IHATE12080**# IHATE22080**# 54,840 87,740 IHATE4208$**# IHATE5208$**# 80,465 1,13,365 1000 50 IHATE12100**# IHATE22100**# 58,425 91,430 IHATE4210$**# IHATE5210$**# 84,050 1,17,055 1250 50 IHATE12120**# IHATE22120**# 75,850 1,11,215 IHATE4212$**# IHATE5212$**# 1,01,475 1,36,840 1600 50 IHATE12160**# IHATE22160**# 79,950 1,18,900 IHATE4216$**# IHATE5216$**# 1,05,575 1,44,525 2000 50 IHATE12200**# IHATE22200**# 89,175 1,41,450 IHATE4220$**# IHATE5220$**# 1,14,800 1,67,075 2500 75 IHATH12250**# IHATH22250**# 1,04,550 1,67,645 IHATH4225$**# IHATH5225$**# 1,30,175 1,83,130 3200 100 IHATV12320**# IHATV22320**# 1,48,625 2,17,210 IHATV4232$**# IHATV5232$**# 1,74,250 2,33,665 4000 100 IHATV12400**# IHATV22400**# 2,17,300 2,58,595 IHATV4240$**# IHATV5240$**# 2,42,925 2,77,290
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-4
Air Circuit Breaker(Conforms to IEC:60947 - 2 / IS: 13947 - 2)
1. Microprocessor Based OCR (IPR)
2. Spring Charging Motor
3. Main CTs *1
4. Neutral CTs *2
5. Under Voltage Trip Device (UVT)
7. Key Lock / Key Interlock
9. Other Accessories
8. Adaptor Type Terminals (additional price) (6 nos. reqd. for 3 pole & 8 nos. for 4 pole ACB)
6. Shunt Trip / Closing Coil
Air Circuit Breaker
S.No. SAP Code Description LP in Rs.
1-1 ISACX0172 IPR-E 10,0001-2 ISACX0214 IPR-1 15,0001-3 ISACX0173 IPR-2 20,0001-4 ISACX0199 IPR-3 45,0001-5 SACX0346 Communication software for IRP-3 Av. on request
S.No. SAP Code Description LP in Rs.
2-1 ISACX0358 Charging Motor 110 V 20,0002-2 ISACX0147 Charging Motor 230 V 20,000
S.No. SAP Code Description LP in Rs.
3-1 ICELFACL018 CT 400A 1,9503-2 ICELFACL001 CT 630A 1,9503-3 ICELFACL002 CT 800A 1,9503-4 ICELFACL003 CT 1000A 1,9503-5 ICELFACL004 CT 1250A 1,9503-6 ICELFACL005 CT 1600A 2,1003-7 ICELFACL006 CT 2000A 2,5003-8 ICELFACL007 CT 2500A 3,000
S.No. SAP Code Description LP in Rs.4-1 ICELFACL019 NCT 400A 1,9504-2 ICELFACL012 NCT 630A 1,9504-3 ICELFACL013 NCT 800A 1,9504-4 ICELFACL014 NCT 1000A 1,9504-5 ICELFACL015 NCT 1250A 1,9504-6 ICELFACL016 NCT 1600A 2,1004-7 ICELFACL017 NCT 2000A 2,5004-8 ICELFACL021 NCT 2500A 3,5004-9 ICELFACL022 NCT 3200A 4,0004-10 ICELFACL023 NCT 4000A 4,500
S.No. SAP Code Description LP in Rs.
5-1 ISACX0193 24 VDC 3,0005-2 ISACX0195 110 VAC/DC 3,0005-3 ISACX0196 220 VAC/DC 3,0005-4 ISACX0197 415 VAC 3,500
S.No. SAP Code Description LP in Rs.7-1 ISACX0353 Key lock (1 lock+1 key) 7507-2 ISACX0181 Key interlock (2 locks+1 keys) 1,4007-3 ISACX0210 Key interlock (3 locks+2 keys) 2,100
S.No. SAP Code Description LP in Rs.9-1 ISACX0301 On/Off Button cover 2509-2 ISACX0207 Spring charge indicatior 4509-3 ISACX0208 Door Interlook 1,7509-4 ISACX0349 Trip indication Switch 4259-5 ISACX0303 Mal Insertation prevention device 4009-6 ISACX0139 Aux. switch (5 c/o additional) 1,2509-7 SACX0182 Position indication switch 1,7509-8 ISACX0302 Field test unit 1,5009-9 ISACX0028 Close open cycle counter 1,5009-10 ISACX0341 Drawout position Lock 1,5009-11 ISACX0340 Mechanical Interlock Av. on request
S.No. SAP Code Description LP in Rs. (each no.)8-1 SACP0174 630/800A 1,5008-2 SACP0175 1000/1250A 2,0008-3 SACP0179 1600A 2,2008-4 SACP0176 2000A 2,500
S.No. SAP Code Description LP in Rs.6-1 ISACX0170 24 VDC 2,5006-2 ISACX0168 110 VAC/DC 2,5006-3 ISACX0167 220 VAC/DC 2,5006-4 ISACX0212 415 VAC 2,500 Shunt trip (Continous rating type) 6-5 SACX0342 24 VDC 3,0006-6 SACX0343 110 VAC/DC 3,0006-7 SACX0344 220 VAC/DC 3,0006-8 SACX0345 415 VAC 3,500
*1 For 3200A & 4000A rating ACBs 2 nos each of 1600 & 2000A CTs are use respectively in series on each pole.*2 This CT is required for GFT in 3 pole ACBs for 4 Pole ACBs main CTs is used as neutral CT.
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-5
*ACBs are supplied with following accessories as standard fittment:
Manual Fixed Manual Drawout Electrical Fixed Electrical Drawout
Aux. Contact Unit 5CO Aux. Contact Unit 5CO Aux. Contact Unit 5CO Aux. Contact Unit 5CO Safety Shutter Shunt Trip Device Safety Shutter Aux. Isolating contact unit Charging Motor Aux. Isolating contact unit Horizontal Terminals Closing Coil Horizontal Terminals Shunt Trip Device Charging Motor Closing Coil
*Additional accessories except standard fittment are available on extra price.*Neutral CT is supplied as a standard fittment in 4 Pole ACBs. *Neutral CT prices are to be added for 3 Pole ACBs for ground fault protection.*All orders should be accompanied with ACB order form included in catalogue.
Closing Coil & Charging Motor
CC (Voltage) CM (Voltage) $
24 220 A
110 220 B
220 220 C
415 220 D
24 110 E
110 110 F
220 110 G
415 110 H
UVT & SHT
UVT (Voltage) SHT (Voltage) **
415 24 01 (Zero one) 415 110 02 415 220 03 415 415 04 415 0 05 220 24 06 220 110 07 220 220 08 220 415 09 220 0 10 110 24 11 110 110 12 110 220 13 110 415 14 110 0 15 24 24 16 24 110 17 24 220 18 24 415 19 24 0 20 0 24 21 0 110 22 0 220 23 0 415 24 0 0 00 (Zero Zero)
Current Transformer #
400A A
630A B
800A C
1000A D
1250A E
1600A F
2000A G
2500A H
3200A I
4000A J
CT Rating is same as of ACB 0 (Zero)
Table 1 Table 2
Table 3
Air Circuit Breaker(Conforms to IEC:60947 - 2 / IS: 13947 - 2)
Air Circuit Breaker
Note : Prices on request1. ACB range 630A to 2000A (65KA) / 75KA2. ACB range 630A to 4000A (IPR 3)
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-6
Air Circuit Breaker
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-7
Air Circuit Breaker
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-8
MCCBs
Note : Switch Disconnector versions in different frame sizes are also available for following ratings (Prices on request)
- G Frame 100A, 125A
# In G 25A / 32A / 40A / 50A / 63A are without extention terminals, however extention terminals are available on request at extra price for these ratings.
Moulded Case Circuit Breakers (AC 415V) Loadline MCCBs (Conforms to IEC:60947-II / IS:13947-II)
Fixed thermal & fixed magnetic setting
Breaking Current Rating Frame Three Pole MRP Capacity Icu (A) Cat. No. at 415V (kA)
25 IHLGET0025
32 IHLGET0032
40 IHLGET0040
10 50 GE* IHLGET0050 1,635 63 IHLGET0063
80 IHLGET0080
100 IHLGET0100
125 IHLGET0125 3,710*without extended terminals and phase barriers
Breaking Current Rating Frame Three Pole MRP Capacity Icu (A) Cat. No. at 415V (kA)
25 IHLGFT0025
32 IHLGFT0032
40 IHLGFT0040
16 50 GF* IHLGFT0050 3,710 63 IHLGFT0063
80 IHLGFT0080
100 IHLGFT0100
*without extended terminals and phase barriers
Breaking Current Rating Frame Single Pole MRP Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. Cat. No. (wSN) at 415V (kA) Cat. No.
25 IHLGSS0025 IHLGST0025 IHLGSF0025
32 IHLGSS0032 IHLGST0032 IHLGSF0032
40 IHLGSS0040 IHLGST0040 IHLGSF0040
10 50 GS# IHLGSS0050 1,000 IHLGST0050 1,875 IHLGSF0050 3,500 63 IHLGSS0063 IHLGST0063 IHLGSF0063
80 IHLGSS0080 IHLGST0080 IHLGSF0080
100 IHLGSS0100 IHLGST0100 IHLGSF0100
125 IHLGSS0125 1,300 IHLGST0125 3,750 IHLGSF0125 4,800 150 IHLGSS0150 1,320 IHLGST0150 4,350 IHLGSF0150 5,400 160 IHLGSS0160 1,340 IHLGST0160 4,350 IHLGSF0160 5,400
neWneW
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-9
Note : Switch Disconnector versions in different frame sizes are also available for following ratings (Prices on request)
- G Frame 100A, 125A
# In G 25A / 32A / 40A / 50A / 63A are without extention terminals, however extention terminals are available on request at extra price for these ratings.
Moulded Case Circuit Breakers (AC 415V) Loadline MCCBs (Conforms to IEC:60947-II / IS:13947-II)
Fixed thermal & fixed magnetic setting
Breaking Current Rating Frame Single Pole MRP Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. Cat. No. (wSN) at 415V (kA) Cat. No.
25 IHLGNS0025 IHLGNT0025 IHLGNF0025
32 IHLGNS0032 IHLGNT0032 IHLGNF0032
40 IHLGNS0040 IHLGNT0040 IHLGNF0040
16 50 GN# IHLGNS0050 1,350 IHLGNT0050 3,790 IHLGNF0050 4,900 63 IHLGNS0063 IHLGNT0063 IHLGNF0063
80 IHLGNS0080 IHLGNT0080 IHLGNF0080
100 IHLGNS0100 IHLGNT0100 IHLGNF0100
125 IHLGNS0125 1,375
MCCBs
Breaking Current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (wSN) at 415V (kA) Cat. No.
25 IHLFNT0025 IHLFNF0025
32 IHLFNT0032 IHLFNF0032
40 IHLFNT0040 IHLFNF0040
35 50 FN IHLFNT0050 5,300 IHLFNF0050 6,270 63 IHLFNT0063 IHLFNF0063
80 IHLFNT0080 IHLFNF0080
100 IHLFNT0100 IHLFNF0100
125 IHLFNT0125 6,100 IHLFNF0125 7,420 160 IHLFNT0160 7,200 IHLFNF0160 8,780 200 IHLFNT0200 8,800 IHLFNF0200 11,600 250 IHLFNT0250 13,600 IHLFNF0250 16,700
Breaking Current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (wSN) at 415V (kA) Cat. No.
25 IHLFHT0025 IHLFHF0025
32 IHLFHT0032 IHLFHF0032
40 IHLFHT0040 IHLFHF0040
50 50 FH IHLFHT0050 7,200 IHLFHF0050 9,370 63 IHLFHT0063 IHLFHF0063
80 IHLFHT0080 IHLFHF0080
100 IHLFHT0100 IHLFHF0100
125 IHLFHT0125 8,200 IHLFHF0125 9,685 160 IHLFHT0160 8,800 IHLFHF0160 11,040 200 IHLFHT0200 10,000 IHLFHF0200 12,570 250 IHLFHT0250 15,200 IHLFHF0250 17,950
Breaking Current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (wSN) at 415V (kA) Cat. No.
25 IHLGHT0025 IHLGHF0025
32 IHLGHT0032 IHLGHF0032
40 IHLGH T0040 IHLGHF0040
25 50 GH# IHLGHT0050 3,880 IHLGHF0050 5,200 63 IHLGHT0063 IHLGHF0063
80 IHLGHT0080 IHLGHF0080
100 IHLGHT0100 IHLGHF0100
125 IHLGHT0125 4,200 IHLGHF0125 5,600 150 IHLGHT0150 4,700 IHLGHF0150 6,000 160 IHLGHT0160 4,700 IHLGHF0160 6,000
neWneW
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-10
MCCBs
Moulded Case Circuit Breakers (AC 415V)
Loadline MCCBs (Conforms to IEC:60947-II / IS:13947-II)
Adjustable thermal* & fixed magnetic setting
Breaking Current Rating Frame Single Pole MRP Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. Cat. No. (wSN) at 415V (kA) Cat. No.
25 IHLASS0025 IHLAST0025 IHLASF0025
32 IHLASS0032 IHLAST0032 IHLASF0032
40 IHLASS0040 IHLAST0040 IHLASF0040
25 50 AS IHLASS0050 2,140 IHLAST0050 4,200 IHLASF0050 5,830 63 IHLASS0063 IHLAST0063 IHLASF0063
80 IHLASS0080 IHLAST0080 IHLASF0080
100 IHLASS0100 IHLAST0100 IHLASF0100
125 IHLASS0125 3,555 IHLAST0125 5,250 IHLASF0125 6,020 160 IHLANS0160 3,980 IHLANT0160 7,300 IHLANF0160 9,060 200 AN IHLANS0200 4,545 IHLANT0200 8,600 IHLANF0200 11,500 250 IHLANS0250 5,110 IHLANT0250 9,825 IHLANF0250 14,000
Breaking Current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (wSN) at 415V (kA) Cat. No.
16 160
AS IHLAST0160 5,565 IHLASF0160 8,000
200 IHLAST0200 5,995 IHLASF0200 8,420
Breaking Current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (wSN) at 415V (kA) Cat. No.
25 IHLANT0025 IHLANF0025
32 IHLANT0032 IHLANF0032
40 IHLANT0040 IHLANF0040
35 50 AN IHLANT0050 5,280 IHLANF0050 6,090 63 IHLANT0063 IHLANF0063
80 IHLANT0080 IHLANF0080
100 IHLANT0100 IHLANF0100
125 IHLANT0125 5,430 IHLANF0125 6,800
Note : *Adjustable thermal (70%-100%)
Switch Disconnector versions in different frame sizes are also available for following ratings (Prices on request)
- A Frame 200A, 250A
In A Frame 25A / 32A / 40A / 50A / 63A are without extention terminals, however extention terminals are available on request at extra price for these ratings.
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-11
MCCBs
Moulded Case Circuit Breakers (AC 415V) Loadline MCCBs (Conforms to IEC:60947-II / IS:13947-II)
Adjustable thermal & adjustable magnetic setting*
Breaking Current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (wSN) at 415V (kA) Cat. No.
160 IHLCNT0160 7,600 IHLCNF0160 9,425 200 IHLCNT0200 8,950 IHLCNF0200 12,945 250 IHLCNT0250 13,900 IHLCNF0250 17,085 35 315 CN IHLCNT0315 17,000 IHLCNF0315 23,200 400 IHLCNT0400 17,000 IHLCNF0400 23,200 500 IHLCNT0500 20,900 IHLCNF0500 24,845 630 IHLCNT0630 20,900 IHLCNF0630 24,845 800 IHLCNT0800 26,150 IHLCNF0800 34,680
Breaking Current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (wSN) at 415V (kA) Cat. No.
160 IHLCHT0160 9,360 IHLCHF0160 13,490 200 IHLCHT0200 10,930 IHLCHF0200 14,850 250 IHLCHT0250 17,490 IHLCHF0250 21,435 50 315 CH IHLCHT0315 18,660 IHLCHF0315 24,045 400 IHLCHT0400 18,660 IHLCHF0400 24,045 500 IHLCHT0500 24,540 IHLCHF0500 29,800 630 IHLCHT0630 24,540 IHLCHF0630 29,800 800 IHLCHT0800 27,500 IHLCHF0800 36,000
Breaking current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (wSN) at 415V (kA) Cat. No.
1000 IHLDNT1000 75,250 IHLDNF1000 86,260 50 1250 DN IHLDNT1250 86,270 IHLDNF1250 1,04,845 1600 IHLDNT1600 92,990 - -
Note : *Adjustable thermal (70%-100%) & adjustable magnetic from 160-315A (5-10 times) / 400-800A (4-10 times)
Switch Disconnector versions in different frame sizes are also available for following ratings (Prices on request)
- C Frame 315A, 400A, 630A, 800A
- D Frame 1250A, 1600A
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-12
MCCBs
Moulded Case Circuit Breakers (DC 250V)
Loadline MCCBs (Conforms to IEC:60947-II / IS:13947-II)
Adjustable thermal* & fixed magnetic setting
Adjustable thermal & adjustable magnetic setting*
Breaking Current Rating Frame Three Pole MRP Capacity Icu (A) Cat. No. at 250VDC (kA)
160 IHMCCHT0160 14,545 200 IHMCCHT0200 16,000 250 IHMCCHT0250 20,555 20 315 CH IHMCCHT0315 21,500 400 IHMCCHT0400 21,500 500 IHMCCHT0500 22,920 630 IHMCCHT0630 22,920 800 IHMCCHT0800 26,090
Breaking Current Rating Frame Three Pole MRP Capacity Icu (A) Cat. No. at 250VDC (kA)
160 IHMCANT0160 10,600 10 200 AN IHMCANT0200 11,500 250 IHMCANT0250 12,965
Note : *Adjustable thermal (70%-100%) & adjustable magnetic from 160-315A (5-10 times) / 400-800A (4-10 times)
It is recommended for DC circuits, two poles are connected in series for the positive phase and the third pole be connected in the negative phase
Fixed thermal & fixed magnetic setting
Breaking Current Rating Frame Three Pole MRP Capacity Icu (A) Cat. No. at 250VDC (kA)
25 IHMCGNT0025
32 IHMCGNT0032
40 IHMCGNT0040
5 50 GN IHMCGNT0050 3,805 63 IHMCGNT0063
80 IHMCGNT0080
100 IHMCGNT0100
125 IHMCGNT0125 4,745
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-13
MCCBs
Description ‘G’ Frame ‘A’ Frame ‘F’ Frame ‘C’ Frame ‘D’ Frame
Cat. No. MRP Cat. No. MRP Cat. No. MRP Cat. No. MRP Cat. No. MRP
Note : Following additional accessories are available on request :
- Terminal Shrouds for G, A, F frame - Dolly Pad Lock for G, A, F, C frame - Factory fitted Castell Lock available in C and D frame
Accessories for Moulded Case Circuit Breakers
Size MCCBs Current Range Cat. No.** MRP (Amps)
1 25-100 IHEF1100 4,170
2 125-200 IHEF2200 4,860
3 250-400 IHEF3400 5,555
4 500-800 IHEF4800 6,250
Earth Fault Relay for MCCBs
# The above prices are inclusive of CT’S
** For operating the Earth Fault Relay a Shunt trip or an UVR has to be used.
Note : *For operating Shunt Trip for G Frame, a separate auxiliary switch would be required in which case one c/o. will be used with the shunt trip, leaving one c/o. free for use. Door mounting clamps for G & AA Frame are supplied free of cost on request basis.
Shunt Trip
18-30Vac, 12-36Vdc IHLLSTG030* 555 IHLLSTA030 655 IHLLSTF030 655 IHLLSTC030 1,150 IHLLSTD030 1,585
100-110Vac IHLLSTG110* 555 IHLLSTA110 655 IHLLSTF110 655 IHLLSTC110 1,150 IHLLSTD110 1,585
220-240Vac IHLLSTG240* 555 IHLLSTA240 655 IHLLSTF240 655 IHLLSTC240 1,150 IHLLSTD240 1,585
380-415Vac — — IHLLSTA415 655 IHLLSTF415 655 IHLLSTC415 1,150 IHLLSTD415 1,585
Under Voltage Release 110-120Vac IHLUVRG110 1,035 IHLUVRA110 1,040 IHLUVRF110 1,040 IHLUVRC110 1,175 IHLUVRD110 1,585
220-240Vac IHLUVRG240 1,035 IHLUVRA240 1,040 IHLUVRF240 1,040 IHLUVRC240 1,175 IHLUVRD240 1,585
380-440Vac IHLUVRG440 1,035 IHLUVRA440 1,040 IHLUVRF440 1,040 IHLUVRC440 1,175 IHLUVRD440 1,585
Auxiliary Contact (250Vac/250Vdc) (450Vac/250Vdc)
1-Changeover IHLLASG1CO 655 IHLLASA1CO 655 IHLLASF1CO 655 IHLLASC1CO 875 IHLLASD1CO 1,170
2-Changeover IHLLASG2CO 660 IHLLASA2CO 960 IHLLASF2CO 815 IHLLASC2CO 1,085 IHLLASD2CO 1,445
Rotary Handle Remote-300mm IHLLRRHG30 815 IHLLRRHA30 960 IHLLRRHF30 960 IHLLRRHC30 1,395 IHLLRRHD30 1,715 Shaft & Interlock
Trip Alarm Contact — — IHLLALA1CO 655 IHLLALF1CO 655 IHLLALC1CO 875 — — (Factor Fitted)
Back Studs — — IHLLBSA250 On req. — — IHLLBSC### On req. — —
Sl.No. Description Cat. No. MRP
1. ‘G’ Frame TP IHEGTP 1,440
2. ‘G’ Frame FP IHEGFP 1,440
3. ‘A’ Frame SP IHEASP 2,165
4. ‘A’ Frame TP IHEATP 2,165
5. ‘A’ Frame FP IHEAFP 2,165
6. ‘F’ Frame TP IHEFTP 2,235
7. ‘F’ Frame FP IHEFFP 2,235
8. ‘C’ Frame TP (400A) IHECTP 6,865
9. ‘C’ Frame FP (400A) IHECFP 6,865
10. ‘C’ Frame TP (800A) IHECTS 8,415
11. ‘C’ Frame FP (800A) IHECFS 8,415
MCCB Enclosures
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-14
MCCBs
Digital Moulded Case Circuit Breakers (AC 415)(with adjustable microprocessor release)(Conforms to IEC:60947-II / IS:13947-II)
Under Voltage Release
Shunt Trip
Auxiliary Contact
Rotary Handle
Accessories ‘F’ Frame MRP
1-Changeover (250Vac/250Vdc) IHLLASF1C0 655
2-Changeover (450Vac/250Vdc) IHLLASF2C0 655
Accessories ‘F’ Frame MRP
Remote-300mm IHLRRHFE30 960
Accessories ‘F’ Frame MRP
110-120Vac IHLUVRF110 1,040
220-240Vac IHLUVRF240 1,040
380-440Vac IHLUVRF440 1,040
Accessories ‘F’ Frame MRP
8-30Vac, 12-36Vdc IHLTFE030 660
100-110Vac IHLTFE110 660
220-240Vac IHLTFE240 815
380-415Vac IHLTFE415 815
Note : Following additional accessories are available on request:
- Dolly Pad Locking Device
- Extended Terminals
- Phase Barriers
- Alarm Contact
- Terminal Shrouds
- Back Studs
*Adjustable thermal (40%-100%) & adjustable magnetic (6-10 times of Ir)
Breaking Current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (sWN) at 415V (kA) Cat. No.
25 IHLFENT0025 IHLFENF0025 32 IHLFENT0032 IHLFENF0032 40 IHLFENT0040 IHLFENF0040 50 IHLFENT0050 IHLFENF0050 35 63 FEN IHLFENT0063 6,090 IHLFENF0063 8,365 80 IHLFENT0080 IHLFENF0080 100 IHLFENT0100 IHLFENF0100 125 IHLFENT0125 7,510 IHLFENF0125 11,020 160 IHLFENT0160 8,316 IHLFENF0160 12,369 200 IHLFENT0200 10,975 IHLFENF0200 15,385 250 IHLFENT0250 14,970 IHLFENF0250 17,740
Breaking Current Rating Frame Three Pole MRP Four Pole MRP Capacity Icu (A) Cat. No. (sWN) at 415V (kA) Cat. No.
25 IHLFEHT0025 IHLFEHF0025 32 IHLFEHT0032 IHLFEHF0032 40 IHLFEHT0040 IHLFEHF0040 50 IHLFEHT0050 9,240 IHLFEHF0050 11,277 63 IHLFEHT0063 IHLFEHF0063 50 80 FEH IHLFEHT0080 IHLFEHF0080 100 IHLFEHT0100 IHLFEHF0100 125 IHLFEHT0125 10,395 IHLFEHF0125 16,685 160 IHLFEHT0160 12,705 IHLFEHF0160 20,190 200 IHLFEHT0200 14,440 IHLFEHF0200 22,710 250 IHLFEHT0250 16,170 IHLFEHF0250 23,285
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-15
EnclosuresConforms to IS:8623, IEC:60439
MCCBs Panel Boards
Sl. No. Description* Cat. No. MRP
1 CABLE ALLEy 2WAy I/C 250A IHBGFCA02 10,750
2 CABLE ALLEy 4WAy I/C 250A / IHBGFCA04 12,480 2WAy I/C 400A
3 CABLE ALLEy 6WAy I/C 250A / IHBGFCA06 14,355 4WAy I/C 400A
4 CABLE ALLEy 8WAy I/C 250A / IHBGFCA08 14,355 6WAy I/C 400A
5 CABLE ALLEy 12WAy I/C 250A/ IHBGFCA12 16,495 8WAy I/C 400A
6 CABLE ALLEy 12WAy I/C 400A IHBGFCA42 19,410
Accessories : Cable Alley (for ‘G’ Frame Panel Boards) - Outgoing FP MCCB, Incomer ‘A’ & ‘C’ Frame MCCB
* Each set of Cable Alley consists of two numbers, one each on LHS and RHS.
Sl. No. Description* Cat. No. MRP**
Meter Module - Analog 1. Provision for Ammeter, Voltmeter IHBGMA00 3,535 - Analog with selector switch
Meter Module - Digital 2. Provision for Ammeter, Voltmeter IHBGMD00 3,535 - Digital with selector switch
3. MCB Module IHBGMC00 3,810
4. Add on Module IHBGAM00 3,535
Bare Meter Module / MCB Module / Add on Module for ‘G’ Frame Panel Boards
* Ammeter, Voltmeter, Selector Switch, Control Fuses, Indicating Lights, MCBs etc. have to be ordered separately and are at extra cost.
** The above prices are for bare module enclosures only.
*** Pre-wired Meter Module, Bare Meter Module, MCB Module and Add on Module are common for all range of above ‘G’ Frame Panel Boards.
Sl. No. Description* Cat. No. MRP**
1 Meter Module - Analog IHBGMW00 10,000 2 Meter Module - Digital IHBGDW00 13,000
Pre-wired Meter Module for ‘G’ Frame Panel Boards with Voltmeter, Ammeter, Selector Switch, CT’s, Control Fuse & Indicating Lights:
Incomer** Outgoing* Cat. No. MRP (No. of Ways)
2 IHBG025002 21,405
4 IHBG025004 26,505
6 IHBG025006 31,295
8 IHBG025008 33,465
12 IHBG025012 42,155
16 IHBG025016 49,090
2 IHBG040002 26,510
4 IHBG040004 31,510
6 IHBG040006 36,280
8 IHBG040008 38,465
12 IHBG040012 47,245
16 IHBG040016 54,075
‘G’ Frame Panel Boards, O/G TP MCCBs G-Frame
250A
“AA” Frame
MCCB
400A
“CN” Frame
MCCB * The outgoings number of ways is the number of “G” Frame FP MCCBs that can be mounted. In case of SP MCCBs the number of MCCBs shall be four times the number of way in FP O/G MCCBs.
** Maximum ratings are indicated for the incoming MCCBs however lower ratings in the same frame can be ordered.
The above prices are for bare enclosures only, incoming and outgoing MCCBs have to be ordered separately.
* The outgoings number of ways is the number of “G” Frame TP MCCBs that can be mounted. In case of SP MCCBs the number of MCCBs shall be three times the number of ways in TP MCCBs.
** Maximum ratings are indicated for the incoming MCCBs however lower ratings in the same frame can be ordered.
The above prices are for bare enclosures only, incoming and outgoing MCCBs have to be ordered separately.
Incomer** Outgoing* Cat. No. MRP (No. of Ways)
2 IHBGF25002 23,455
4 IHBGF25004 29,155
6 IHBGF25006 34,425
8 IHBGF25008 36,810
12 IHBGF25012 54,000
2 IHBGF40002 29,160
4 IHBGF40004 34,660
6 IHBGF40006 39,910
8 IHBGF40008 42,310
12 IHBGF40012 59,485
‘G’ Frame Panel Boards, O/G FP MCCBs G-Frame
250A
“AA” Frame
MCCB
400A
“CN” Frame
MCCB
Sl. No. Description* Cat. No. MRP
1 Cable Alley 2WAy I/C 250A IHBGC002 9,770
2 Cable Alley 4WAy I/C 250A / IHBGCA04 11,345 2WAy I/C 400A
3 Cable Alley 6W I/C 250A / IHBGCA06 13,050 4W I/C 400A
4 Cable Alley 8WAy I/C 250A IHBGCA08 13,050
5 Cable Alley 12WAy I/C 250A / IHBGCA12 14,995 6 & 8WAy I/C 400A
6 Cable Alley 16WAy I/C 250A / IHBGCA16 17,645 12WAy I/C 400A
7 Cable Alley 16WAy I/C 400A IHBGCA46 18,655
Accessories : Cable Alley (for ‘G’ Frame Panel Boards) - Outgoing TP MCCB, Incomer ‘A’ & ‘C’ Frame MCCB
* Each set of Cable Alley consists of two numbers, one each on LHS and RHS.
With Three
Pole outgoing
MCCB
With Four
Pole outgoing
MCCB EnclosuresConforms to IS:8623, IEC:60439
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-16
EnclosuresConforms to IS:8623, IEC:60439
Incomer** Outgoing* Cat. No. MRP (No. of Ways)
6 IHBA040006 54,315
8 IHBA040008 56,485
12 IHBA040012 76,035
6 IHBA080006 58,645
8 IHBA080008 60,840
12 IHBA080012 80,395
‘A’ Frame Panel Boards, O/G TP MCCBs
400A “CN/CH” FrameMCCB
800A “CN/CH” FrameMCCB
* The outgoings number of ways is the number of “A” Frame TP MCCBs that can be mounted.
** Maximum ratings are indicated for the incoming MCCBs however lower ratings in the same frame can be ordered.
The above prices are for bare enclosures only, incoming and outgoing MCCBs have to be ordered separately.
Sl. No. Description* Cat. No. MRP 1 Cable Alley 6WAy 400A IC IHBACA06 15,065
2 Cable Alley 8WAy 400A IC IHBACA08 15,065
3 Cable Alley 12WAy 400A IC IHBACA12 17,225
Sl. No. Description* Cat. No. MRP 1 Cable Alley 6WAy 800A IC IHBBCA06 17,325
2 Cable Alley 8WAy 800A IC IHBBCA08 17,325
3 Cable Alley 12WAy 800A IC IHBBCA12 19,810
Accessories : Cable Alley ‘A’ Frame Panel Boards I/C 400A ‘C’ Frame MCCB
Accessories : Cable Alley ‘A’ Frame Panel Boards I/C 800A ‘C’ Frame MCCB
* Each set of Cable Alley consists of two numbers, one each on LHS and RHS.
* Each set of Cable Alley consists of two numbers, one each on LHS and RHS.
Sl. No. Description* Cat. No. MRP**
Meter Module - Analog 1. Provision for Ammeter, Voltmeter IHBAMA00 4,065 - Analog with selector switch
Meter Module - Digital 2. Provision for Ammeter, Voltmeter IHBAMD00 4,065 - Digital with selector switch
3. MCB Module IHBAMC00 4,380
4. Add on Module IHBAAM00 4,065
Bare Meter Module / MCB Module / Add on Module for ‘A’ Frame Panel Boards
* Ammeter, Voltmeter, Selector Switch, Control Fuses, Indicating Lights, MCBs etc. have to be ordered separately and are at extra cost.
** The above prices are for bare module enclosures only.
Sl. No. Description* Cat. No. MRP**
1 Meter Module - Analog IHBAMW00 12,000
2 Meter Module - Digital IHBADW00 14,500
Pre-wired Meter Module for ‘A’ Frame Panel Boards with Voltmeter, Ammeter, Selector Switch, CT’s, Control Fuse & Indicating Lights:
MCCBs Panel Boards
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-17
Contactor
Control Relays and Contactors
Control Relays : AC Operated Frame AC 15 Duty Description Contact Type Cat. No. MRP (MM/Size) Rating Configuration (Amps.)
45/1 CR / 6A AC Magnet 2NO + 2NC CR4K1.22* IHPCR22* 600 Base Block 3NO + 1NC CR4K1.31* IHPCR31* 600
4 Pole 4NO CR4K1.40* IHPCR40* 600
Contactors : AC Operated (9A to 400A) IS:13947-4, IEC:60947-4
Frame AC 3 Duty Rating AC1 Duty Power Auxiliary Type Cat. No. MRP (MM/Size) At 415V. 50Hz Rating Poles Contact At 415V (No.) Arrangement
Amp. Kw H.P. Amp. No NC
9 4 5.5 25 3 1 0 PC4K1.10* IHP004110* 565 9 4 5.5 25 3 0 1 PC4K1.01* IHP004101* 565 45/1 12 5.5 7.5 25 3 1 0 PC5K1.10* IHP005110* 600 12 5.5 7.5 25 3 0 1 PC5K1.01* IHP005101* 600 16 7.5 10 32 3 1 0 PC7K1.10* IHP007110* 680 16 7.5 10 32 3 0 1 PC7K1.01* IHP007101* 680
18 9 12.5 50 3 1 1 PC9K2* IHP009211* 740 45/2 25 11 15 50 3 1 1 PC11K2* IHP011211* 905 32 15 20 50 3 1 1 PC15K2* IHP015211* 1,650
40 22 30 100 3 1 1 PC22K3* IHP022311* 2,100 80/3 50 25 35 100 3 1 1 PC25K3* IHP025311* 2,525 70 37 50 125 3 1 1 PC37K3* IHP037311* 4,575 80 40 54 125 3 1 1 PC40K3* IHP040311* 4,930
95 45 60 150 3 1 1 PC45K4.11* IHP045411* 5,420 118/4 125 63 85 160 3 1 1 PC63K4.11* IHP063411* 7,200 140 75 100 170 3 1 1 PC75K4.11* IHP075411* 9,700 170 90 125 200 3 1 1 PC90K4.11* IHP090411* 12,885
250 140 190 350 3 1 1 PC140K6N11* IHP140611* 15,500 160/6 325 185 250 390 3 1 1 PC185K6N11* IHP185611* 18,000 400 220 300 450 3 1 1 PC220K6N11* IHP220611* 22,500
* To Complete Cat. No. Suffix Voltage Code from Coil Voltage Table on Page No.18.
NOTE : 1. For additional aux. contacts front/side mounted add-on contact blocks, surge suppressors and mechanical interlock refer accessories table. 2. Four pole contactors upto 7.5kw/16A available on request. 3. Non standard coil voltages are supplied at an extra price offered on request.
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-18
Accessories
Attachment Accessories for Contactors (Size 1 to 4)Add-on Auxiliary Contact Blocks
Description Mounting Contact Type Cat. No. MRP on Configuration 1.5 Contactors No NC
CR4K1 / CR 1 1 L.11 ISPAXFM311 80 Front Mounted & 3 1 L.31 ISPAXFM331 145 PC4K1 / 9A to 2 2 L.22 ISPAXFM322 145 PC37K3 / 70A 4 0 L.40 ISPAXFM340 145
CR4K1/ CR 1 1 S.11 ISPAXSM311 90 Side Mounted & PC4K1 / 9A to PC37K3 / 70A 2 0 S.20 ISPAXSM320 90
PC45K4 / 95A to PC90K4 / 170A 1 1 4S.11* ISPAXSM411 185
Note: * max. 2NO+2NC Aux. contacts on each side can be achieved.
Code Standard Non Standard A0 B0 C0 D0 E0 F0 G0 A1 A2 W1 W2 G1 G2
AC Voltage 50 Hz 24 48 110 220 240 380 415 36 42 240 to 415 250 to 415 440 550
60 Hz 120 240 480
Coil Voltage Table :
NOTE : Wideband Coil code ‘W1’ is suitable for Frame size 1&2 and code ‘W2’ is suitable for Frame size 3 & 4.
Description Mounting Contact Type Cat. No. MRP on Configuration 1.5 Contactors No Nc
Left Side Mounted PC140K6 / 250A 1 1 5S.11L* ISPAXLM611 380 to Right Side Mounted PC220K6 / 400A 1 1 5S.11R* ISPAXRM611 380
Note: *max. 2NO+2NC Aux. contacts on each side can be achieved.
Attachment Accessories for Contactors (Size 5 & 6)Add-on Auxiliary Contact Blocks
Mechanical Interlock (Size 1 to 3)
Description For use with Mounting on Type Cat. No. MRP Contactors Contactors
Block Type CR4K1 / CR Side Mounted MV ISPMI1SV 220 & Vertical Plane PC4K1 / 9A to PC40K3 / 80A
Surge Suppressors (Size 1 & 2)
Description For use with Voltage Mounting on Type Cat. No. MRP Contactors Range Contactors
For Suppression of CR4K1 / CR 24 - 48 AC On VK01 ISPSS2048 130 Disturbances Caused & 72 - 140 AC Dove Tail VK02 ISPSS2140 130
By Coil Switching on PC4K1 / 9A to 110 - 240 AC At VK03 ISPSS2240 130 Electronic Circuit Pc15k2 / 32a Bottom Part
Control Relays
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-19
Contactor Mounting Type with (1 NO + 1 NC) Potential Free Contacts
Thermal Overload Relays
Relay Setting Suitable for Auto Reset Auto/ Manual Reset MRP
Range in Amps Mounting on Type Cat. No. Type Cat. No. Contactors
0.16 - 0.24 TRM23.AA IHTR23AA TRM23.A IHTR23MA 785 0.24 - 0.38 TRM23.BA IHTR23AB TRM23.B IHTR23MB 785 0.38 - 0.6 TRM23.CA IHTR23AC TRM23.C IHTR23MC 785 0.6 - 0.9 PC4K1/9A TRM23.DA IHTR23AD TRM23.D IHTR23MD 785 1.0 - 1.6 to TRM23.EA IHTR23AE TRM23.E IHTR23ME 785 1.7 - 2.5 PC7K1/16A TRM23.FA IHTR23AF TRM23.F IHTR23MF 785 2.2 - 3.4 TRM23.GA IHTR23AG TRM23.G IHTR23MG 785 3.0 - 4.5 TRM23.HA IHTR23AH TRM23.H IHTR23MH 785 4.5 - 7.0 TRM23.JA IHTR23AJ TRM23.J IHTR23MJ 785 6.5 - 10.0 TRM23.KA IHTR23AK TRM23.K IHTR23MK 785 10.0 - 15.0 TRM23.LA IHTR23AL TRM23.L IHTR23ML 785 13 - 19.5 TRM23.M\A IHTR23AM TRM23.M IHTR23MM 840
6.5 - 10.0 TRM24.KA IHTR24AK TRM24.K IHTR24MK 840 10.0 - 15.0 PC9K2/18A TRM24.LA IHTR24AL TRM24.L IHTR24ML 840 13.0 - 19.5 to TRM24.MA IHTR24AM TRM24.M IHTR24MM 840 15.0 - 22.0 PC15K2/32A TRM23.NA IHTR24AN TRM24.N IHTR24MN 840 16.0 - 25.0 TRM23.RA IHTR24AR TRM24.R IHTR24MR 840
24.0 - 34.0 TRM24.SA IHTR24AS TRM24.S IHTR24MS 1,100
Note :1. For optional Individual Mounting Terminal Block
for Overload Relay TRM023 / TRM024 ask for Cat. No. “TB34” Unit Price on request and Overload relay TRM022 ask Cat. No. “ASM22” Unit Price on request.
2. Auto / Manual Reset Overload Relay type TRM023 / TRM024 are available with additional Price of Rs. 20 each over the above unit price.
Relay Setting Type Cat. No. MRP Range in Amps
24.0 - 36.0 CTR.36 IHTCR036 1,195 26.0 - 40.0 CTR.40 IHTCR040 1,295 34.0 - 51.0 CTR.51 IHTCR051 1,810
40.0 - 60.0 CTR.60 IHTCR060 1,860 50.0 - 75.0 CTR.75 IHTCR075 2,230 70.0 - 105.0 CTR.105 IHTCR105 2,230
100.0 -150.0 CTR.150 IHTCR150 2,795 135.0 - 200.0 CTR.200 IHTCR200 4,770 180.0 - 270.0 CTR.270 IHTCR270 6,190 260.0 - 400.0 CTR.400 IHTCR400 6,190
C.T. Mounted Thermal Overload RelayRelay Setting Suitable for MRPRange in Amps Mounting on Type Cat. No. Contactors
16.0 - 25.0 TRM75.25 IHTR7525 1,280
20.0 - 32.0 TRM75.32 IHTR7532 1,280
25.0 - 40.0 TRM75.40 IHTR7540 1,280
32.0 - 50.0 TRM75.50 IHTR7550 1,280
40.0 - 57.0 TRM75.57 IHTR7557 2,145
50.0 - 63.0 TRM75.63 IHTR7563 2,145
57.0 - 70.0 TRM75.70 IHTR7570 2,145
63.0 - 80.0 TRM75.80 IHTR7580 2,145
PC22K3/40Ato
PC40K3/80A
For Auto/Manual Reset
Contactor Mounting Thermal Overload Relays
Thermal Overload Relays
Voltage Table :AC Voltage (V) 024 048 110 220/240 435
Ordering Example : On delay timer with 1 - 12 SEC. Timing and 220V Supply, the complete cat. no. will be TESD1220
Note : To complete Cat No. replace *** with required Voltage from the Voltage Table. While ordering 024/048/110V/240/415V Check with works.
Type Cat. No. Timing Range MRP
ETSD1* IHRS1 *** 1 - 12 Sec. 480 ETSD2* IHRS2 *** 3 - 30 Sec. 480 ETSD3* IHRS3 *** 12 - 120 Sec. 480
Electronic Timer for Star-Delta Starters
*Coil Voltage can be taken from the “Coil Voltage Table” at Page No. 18
CoilsDescription Type Cat. No. MRPfor use with Contactor
PC 4K-PC 7K & CR 4K SP PC 1_ ISPPSCL1* 180
PC 9K-PC 15K SP PC 2_ ISPPSCL2* 190
PC 22K-PC 37K SP PC 3_ ISPPSCL3* 595
PC 45K-PC 75K SP PC 4_ ISPPSCL4* 980
PC 90K5 SP PC 5_ ISPPSCL5* 1,610
PC 140K6-220K6 SP PC 6_ ISPPSCL6* 2,505
Spares
Contact Kits for ContactorsDescription For use with Cat. No. MRP Contactors
CR4K1.22/CR ISP004C122 290 CR4K1.31/CR ISP004C131 290Complete Top CR4K1.40/CR ISP004C140 290Housing Block PC4K1.10/9A ISP004C110 315Consisting of PC4K1.01/9A ISP004C101 315Moving Contacts PC5K1.10/12A ISP005C110 345Fixed Contacts PC5K1.01/12A ISP005C101 345and Moving PC7K1.10/16A ISP007C110 405Magnet System PC7K1.01/16A ISP007C101 405 PC9K2/18A ISP009C200 415 PC11K2/25A ISP011C200 490 PC15K2/32A ISP015C200 1,190
Contactor Kit PC22K3/40A ISP022C300 865Comprising of Six PC25K3/50A ISP025C300 1,255Fixed Contacts Three PC37K3/70A ISP037C300 1,545Moving Contacts, PC45K4/95A ISP045C400 2,145Springs and Arc PC63K4/125A ISP063C400 2,800Chutes PC75K4/140A ISP075C400 3,575
Contact Kit
Comprising of Six PC90K5/170A ISP090C500 4,765Fixed Contacts Three PC140K6/250A ISP140C600 5,475Moving Contacts, PC185K6/325A ISP185C600 6,665Screws and Washers PC220K6/400A ISP220C600 10,120
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-20
Motor Starters
Contactor Overload Type Cat. No. MRP
Size Relay Range
H.P. Kw (Amp.)
0.75 0.52 PC7K1/16A 1.0 - 1.6 DOLEE1* IHPDOLE1*0 1,280 1.0 0.75 PC7K1/16A 1.7 - 2.5 DOLFE1* IHPDOLF1*0 1,280 2.0 1.5 PC7K1/16A 3.0 - 4.5 DOLHE1* IHPDOLH1*0 1,280 3.0 2.2 PC7K1/16A 4.5 - 7.0 DOLHE1* IHPDOLJ1*0 1,280 5.0 3.7 PC7K1/16A 6.5 - 10.0 DOLKE1* IHPDOLK1*0 1,280 7.5 5.5 PC7K1/16A 10.0 - 15.0 DOLLE1* IHPDOLL1*0 1,280
10.0 7.5 PC9K2/18A 13.0 - 19.5 DOLME1* IHPDOLM1*0 1,340
15.0 11.0 PC11K2/25A 15.0 - 22.0 DOLNE2* IHPDOLN2*0 2,500 20.0 15.0 PC15K2/32A 24.0 - 34.0 DOLSE2* IHPDOLS2*0 3,600
25.0 18.5 PC22K3/40A 26.0 - 40.0 DOL40E3* IHPDOLT3*0 5,870 30.0 22.0 PC25K3/50A 34.0 - 51.0 DOL50E3* IHPDOLU3*0 6,345 40.0 30.0 PC37K3/70A 40.0 - 60.0 DOL57E3* IHPDOLV3*0 7,675 50.0 37.0 PC37K3/70A 50.0 - 75.0 DOL70E3* IHPDOLW3*0 8,695
60.0 45.0 PC45K4/95A 70.0 - 105.0 DOLA05E4* IHPDOLX4*0 11,750 75.0 55.0 PC63K4/125A 100.0 - 150.0 DOLB50E4* IHPDOLy4*A 14,095 85.0 63.0 PC63K4/125A 100.0 - 150.0 DOLC50E4* IHPDOLy4*B 15,860 100.0 75.0 PC75K4/140A 100.0 - 150.0 DOLD50E4* IHPDOLy4*C 17,620
Max. Motor Output At 415V, 3-Ph.
Max. Motor Output At 415V, 3-Ph.
(Conforms to IS:13947-4)
Direct Online Starter
Reversing Starter
2.0 1.5 PC7K1/16A 3.0 - 4.5 ROLHE1* IHPREVH1*0 3,940 3.0 2.2 PC7K1/16A 4.5 - 7.0 ROLJE1* IHPREVJ1*0 3,940 5.0 3.7 PC7K1/16A 6.5 - 10.0 ROLKE1* IHPREVK1*0 3,940 7.5 5.5 PC7K1/16A 10.0 - 15.0 ROLLE1* IHPREVL1*0 3,940 10.0 7.5 PC9K2/18A 13.0 - 19.5 ROLME1* IHPREVM1*0 4,410
15.0 11.0 PC11K2/25A 15.0 - 22.0 ROLNE2* IHPREVN2*0 4,675 20.0 15.0 PC15K2/32A 24.0 - 34.0 ROLSE2* IHPREVS2*0 6,300
Note :(A) * Suffix Coil code from Coil Voltage Table given with contactor table for Powerline Motor Starters.
For other Overload Relays replace Relay Code to required current setting range.
(B) All Powerline Motor Starters are supplied with type “TRM-23/TRM-24” Thermal Overload Relays with Auto Reset Facility.
Motor Starter
Automatic Star-Delta Starter
Contactor Overload Type Cat. No. MRP
Size Relay Range
H.P. Kw (Amp.)
10.0 7.5 PC7K1/16A 6.5 - 10.0 ASDKE1* IHPASDK1*0 4,830 12.5 9.3 PC7K1/16A 10.0 - 15.0 ASDLAE1* IHPASDL1*A 5,040 15.0 11.0 PC7K1/18A 10.0 - 15.0 ASDLBE1* IHPASDL1*B 5,040 20.0 15.0 PC9K2/18A 13.0 - 19.5 ASDME2* IHPASDM2*0 5,880 25.0 18.5 PC11K2/25A 15.0 - 22.0 ASDNE2* IHPASDN2*0 6,100 30.0 22.5 PC11K2/32A 16.0 - 25.0 ASDRE2* IHPASDR2*0 7,665
35.0 26.0 PC15K2/32A 24.0 - 34.0 ASDSE2* IHPASDS2*0 9,800 50.0 37.0 PC22K3/40A 26.0 - 40.0 ASD40E3* IHPASDT3*0 14,800 60.0 45.0 PC25K3/50A 34.0 - 51.0 ASD50E3* IHPASDU3*0 24,000 75.0 55.0 PC37K3/70A 40.0 - 60.0 ASD57E3* IHPASDV3*0 24,700
90.0 67.5 PC37K3/70A 50.0 - 75.0 ASD70E3* IHPASDW3*0 29,000 100.0 75.0 PC45K4/95A 70.0 - 105.0 ASDA05E4* IHPASDX4*0 35,700
125.0 90.0 PC63K4/125A 70.0 - 105.0 ASDB05E4* IHPASDX4*0 38,000 150.0 110.0 PC63K4/125A 100.0 - 150.0 ASDC50E4* IHPASDy4*0 42,000
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-21
Confirms to IS: 13947-4
Submersible Starter - Phase
Direct On Line (DOL) Submersible StarterMax. Motor Output Contactor Overload Cat No. MRPAt 415V, 3-Phase Size Relay Range #H.P. Kw (Amps)
5 3.7 PC9K2 6.5-10 IHPSDOLKEKS 4615
7.5 5.5 PC9K2 10-15 IHPSDOLLEKS 4770
10 7.5 PC11K2 13.19.5 IHPSDOLMEKS 5000
12.5 9.3 PC11K2 15-22 IHPSDOLNFKS 5075
15 11 PC15K2 16-25 IHPSDOLRGKS 5075
Standard Automatic Star Delta (ASD) Submersible Starter
Max. Motor Output Contactor Overload Cat No. MRPAt 415V, 3-Phase Size Relay Range #H.P. Kw (Amps)
5 3.7 PC9K2 6.5-10 IHPSASDKEKS 8615
7.5 5.5 PC9K2 6.5-10 IHPSASDKEKSA 8615
10 7.5 PC9K2 10-15 IHPSASDLEKS 8850
12.5 9.3 PC9K2 10-15 IHPSASDLEKSA 8850
15 11 PC11K2 13-19.5 IHPSASDMFKS 8925
17.5 13.1 PC15K2 15-22 IHPSASDNGKS 9000
20 15 PC15K2 16-25 IHPSASDRGKS 9000
22.5 16.8 PC15K2 24-34 IHPSASDSGKS 9080
25 19 PC15K2 24-34 IHPSASDSGKSA 9080
Premium Automatic Star Delta (ASD) Submersible Starter
Max. Motor Output Contactor Overload Cat No. MRPAt 415V, 3-Phase Size Relay Range #H.P. Kw (Amps)
5 3.7 PC9K2 6.5-10 IHPSASDKEKP 8770
7.5 5.5 PC9K2 6.5-10 IHPSASDKEKPA 8770
10 7.5 PC9K2 10-15 IHPSASDLEKP 9000
12.5 9.3 PC9K2 10-15 IHPSASDLEKPA 9160
15 11 PC11K2 13-19.5 IHPSASDMFKP 9160
17.5 13.1 PC15K2 15-22 IHPSASDNGKP 9160
20 15 PC15K2 16-25 IHPSASDRGKP 9160
22.5 16.8 PC15K2 24-34 IHPSASDSGKP 9385
25 19 PC15K2 24-34 IHPSASDSGKPA 9385
# Overload Relay ratings Amps are subject to motor efficiency, Voltage & Utilization. Standard supply is with wide band coil 240V-415V AC, other Standard Coil Voltages are suppled on request.
Direct Online Starter(5HP to 15 HP)
Standard Automatic Star Delta Starter(5HP to 25HP)
Premium Automatic Star Delta Starter(5HP to 25HP)
neWneW
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-22Changeover Switches
Four Pole Changeover with Advance NeutralConforms to IS:13947 (Part-3); IEC:60947-3
On-Load Changeover Switch I-O-II
Note : # Prices on request* Phase Barriers & Handle with door interlock kit is integral part of the Changeover Switch.** Aux. contacts for signalling and electrical interlocking are optional and provided at extra price.
Frame Current Open MRP SS MRP Size Rating Execution Enclosure (Amps) Cat. Code Cat. Code
0 125 IHCNFO0125 7,325 IHCNFE0125 9,750
0 160 IHCNFO0160 7,700 IHCNFE0160 11,000
0 200 IHCNFO0200 9,520 IHCNFE0200 12,000
1 250 IHCNFO0250 13,700 IHCNFE0250 16,500
1 320 IHCNFO0320 14,400 IHCNFE0320 17,500
2 400 IHCNFO0400 20,750 IHCNFE0400 25,500
2 630 IHCNFO0630 24,750 IHCNFE0630 29,500
3 800 IHCNFO0800 35,700 IHCNFE0800 42,200
4 1000 IHCNFO1000 58,500 IHCNFE1000 73,500
4 1250 IHCNFO1250 82,000 IHCNFE1250 98,000
4 1600 IHCNFO1600 1,13,500 IHCNFE1600 1,30,500
5 2000 IHCNFO2000 1,40,000 IHCNFE2000 1,71,000
5 2500 IHCNFO2500 1,86,000 IHCNFE2500 2,22,000
5 3150 IHCNFO3150 2,55,000 IHCNFE3150 2,95,000
Frame Current Open MRP Size Rating Execution (Amps) Cat. Code
0 125 IHCBFO0125 11,500
0 160 IHCBFO0160 13,745
0 200 IHCBFO0200 14,575
1 250 IHCBFO0250 20,760
1 320 IHCBFO0320 21,630
2 400 IHCBFO0400 31,350
2 630 IHCBFO0630 39,170
3 800 IHCBFO0800 43,445
3 1000 IHCBFO1000 82,620
Four Pole By Pass SwitchConforms to IS:13947 (Part-3); IEC:60947-3
Accessories :
Aux. Contact Cat. No. MRP
1 NO. 1 NC. IHCNFAC1CO 290
2 NO. 2 NC. IHCNFAC2CO 365
Extension Shaft + Channel-Set IHCNFOESCS 340
Four Pole ChangeoverConforms to IS:13947 (Part-3); IEC:60947-3
On-Load Changeover Switch I-O-II
Four Pole By Pass Switch Conforms to IS:13947 (Part-3); IEC:60947-3
Frame Current Open MRP Size Rating Execution (Amps) Cat. Code
00 063 IHCBFO0063 7,560
00 100 IHCBFO0100 9,030
Frame Current Open MRP SS MRP Size Rating Execution Enclosure (Amps) Cat. Code Cat. Code
00 040 IHCNFO0040 3,570 IHCNFE0040 5,040
00 063 IHCNFO0063 3,780 IHCNFE0063 5,300
00 080 IHCNFO0080 4,675 IHCNFE0080 6,145
00 100 IHCNFO0100 5,670 IHCNFE0100 7,425
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-23
Automatic/Manual with inbuilt Time delay
Rating Cat. No. MRP Cat. No. MRP AMP. 3P Three Pole 4P Four Pole
Open Execution
100 IHyTSA0100 27,095 IHyFSA0100 30,200
160 IHyTSA0160 36,410 IHyFSA0160 39,090
200 IHyTSA0200 45,220 IHyFSA0200 48,325
315 IHyTSA0315 54,095 IHyFSA0315 57,200
400 IHyTSA0400 66,975 IHyFSA0400 70,090
630 IHyTSA0630 83,415 IHyFSA0630 86,515
With Enclosure
100 IHyTSAE100 29,950 IHyFSAE100 33,050
160 IHyTSAE160 39,265 IHyFSAE160 41,930
200 IHyTSAE200 48,055 IHyFSAE200 51,170
315 IHyTSAE315 56,945 IHyFSAE315 60,055
400 IHyTSAE400 72,495 IHyFSAE400 75,600
630 IHyTSAE630 88,920 IHyFSAE630 92,035
Automatic Transfer Switch (ATS)Automatic Transfer Switch
(Conforms to IEC:60947-1 and IEC:60947-6-1)
Three / Four Pole, AC-33A, 50 Hz, 440V
Automatic Transfer Switch
Note : Replace # with T - 3 Pole switch F - 4 Pole switch
Automatic/Manual with inbuilt Time delay (with Primary Protection against Single phasing, Over Voltage, Under Volt-age available with 12V D.C. control only)
Rating Cat. No. MRP MRP Amp. Three Pole Four Pole
Open Execution
100 IHy#PD0100 34,200 35,535
160 IHy#PD0160 41,750 44,420
200 IHy#PD0200 50,550 53,650
315 IHy#PD0315 59,425 62,525
400 IHy#PD0400 72,305 75,430
630 IHy#PD0630 88,730 91,840
With Enclosure
100 IHy#PDE100 35,265 38,370
160 IHy#PDE160 44,695 47,265
200 IHy#PDE200 53,390 56,495
315 IHy#PDE315 62,295 65,380
400 IHy#PDE400 77,805 80,920
630 IHy#PDE630 94,245 97,360
Automatic Switch Phase Corrector Unit
Rating Cat. No. MRP AMP. 4p Four Pole
With Enclosure100 IHyFRAE100 38,370160 IHyFRAE160 47,265200 IHyFRAE200 56,495315 IHyFRAE315 65,380400 IHyFRAE400 80,920630 IHyFRAE630 97,360
AccessoriesType Cat. No. MRP
Controller unit for ATS ICCPAyAX001 5,010Protection unit for mains ICCPAyAX002 7,680On line float charger cum UPS ICELDL00104 4,935
* Battery not included as part of Online Float Charger cum UPS.
Automatic/Manual with inbuilt Time delay
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-24
Switch Disconnector
Frame Current Open MRP SS MRP Size Rating Execution Enclosure
(Amps) Cat. Code Cat. code
00 40 IHCSFO0040 1,250 IHCSFE0040 2,000
00 63 IHCSFO0063 1,480 IHCSFE0063 2,230
00 80 IHCSFO0080 2,200 IHCSFE0080 2,950
00 100 IHCSFO0100 3,550 IHCSFE0100 4,300
0 125 IHCSFO0125 3,785 IHCSFE0125 4,740
0 160 IHCSFO0160 4,530 IHCSFE0160 5,475
0 200 IHCSFO0200 5,465 IHCSFE0200 6,540
1 250 IHCSFO0250 6,855 IHCSFE0250 8,795
1 320 IHCSFO0320 7,510 IHCSFE0320 9,345
2 400 IHCSFO0400 10,425 IHCSFE0400 12,910
2 630 IHCSFO0630 11,940 IHCSFE0630 14,570
3 800 IHCSFO0800 16,575 IHCSFE0800 20,790
4 1000 IHCSFO1000 26,920 IHCSFE1000 33,660
4 1250 IHCSFO1250 37,665 IHCSFE1250 44,960
4 1600 IHCSFO1600 53,040 IHCSFE1600 61,095
5 2000 IHCSFO2000 63,750 IHCSFE2000 80,445
5 2500 IHCSFO2500 82,725 IHCSFE2500 1,05,295
5 3150 IHCSFO3150 1,16,700 IHCSFE3150 1,36,045
Four Pole, 415V
Conforms to IS:13947 (Part -3); IEC:60947-3Three Pole, 415V
Switch Disconnector
Frame Current Open MRP SS MRP Size Rating Execution Enclosure
(Amps) Cat. Code Cat. code
0 80 IHCSTO0080 1,670 IHCSTE0080 2,585
0 100 IHCSTO0100 2,730 IHCSTE0100 3,840
0 125 IHCSTO0125 3,625 IHCSTE0125 4,670
0 160 IHCSTO0160 4,325 IHCSTE0160 5,370
0 200 IHCSTO0200 4,905 IHCSTE0200 6,025
1 250 IHCSTO0250 6,130 IHCSTE0250 7,745
1 320 IHCSTO0320 6,735 IHCSTE0320 8,475
1 400 IHCSTO0400 9,690 IHCSTE0400 11,570
Switch Disconnector
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-25
Switch Disconnector Fuse
Switch Disconnector Fuse UnitSwitch Disconnector Fuse Unit (Panel Mounting Cubicle Type) Conforms to IS:13947 (Part I & III)Double Pole - AC-23A, 50Hz, 415V
Switch Disconnector Fuse UnitSwitch Disconnector Fuse (Panel Mounting Cubicle Type) Conforms to IS:13947 (Part I & III)Three Pole & Neutral - AC-23A, 50Hz, 415V
* All switch disconnector fuse units if required without fuse link will be made available on request.
* IHFSTO/W 4800 and IHFKTO/W 4800 available without Fuse Link. (Price on request)
Switch Disconnector Fuse Unit
Rating Cat. No. MRP Cat. No. MRP HBC Fuse Amp. Type
Open In Sheet Execution Steel Encl. with Fuses with Fuses 32 IHFDDF4032 1,305 IHFDDW4032 1,850 IHHTIA0032
32 IHFFDF4032 1,600 IHFFDW4032 2,120 IHHCD00032
63 IHFDDF4063 1,875 IHFDDW4063 2,300 IHHTSS0063
63 IHFFDF4063 2,130 IHFFDW4063 2,645 IHHCD00063
100 IHFDDF4100 3,910 IHFDDW4100 4,480 IHHTSD0100
100 IHFFDF4100 4,025 IHFFDW4100 4,570 IHHCD00100
125 IHFDDF4125 4,050 IHFDDW4125 4,625 IHHTSD0125
125 IHFFDF4125 4,430 IHFFDW4125 4,975 IHHCD00125
Rating Cat. No. MRP Cat. No. MRP HBC Fuse Amp. Type
Open In Sheet Execution Steel Encl. with 3 Fuses with 3 Fuses
32 IHFDTF4032 1,380 IHFDTW4032 2,345 IHHTIA0032
32 IHFFTF4032 1,840 IHFFTW4032 2,735 IHHCD00032
63 IHFDTF4063 2,040 IHFDTW4063 2,910 IHHTSS0063
63 IHFFTF4063 2,465 IHFFTW4063 3,230 IHHCD00063
100 IHFDTF4100 4,295 IHFDTW4100 5,720 IHHTSD0100
100 IHFFTF4100 4,320 IHFFTW4100 5,825 IHHCD00100
125 IHFDTF4125 4,880 IHFDTW4125 6,140 IHHTSD0125
125 IHFFTF4125 5,095 IHFFTW4125 6,260 IHHCD00125
Rating Cat. No. MRP Cat. No. MRP HBC Fuse Amp. Type
Open In Sheet Execution Steel Encl. with 3 Fuses with 3 Fuses
160 IHFSTF4160 5,940 IHFSTW4160 8,215 IHHTSF0160
160 IHFKTF4160 6,575 IHFKTW4160 8,590 IHHCD01160
200 IHFSTF4200 6,590 IHFSTW4200 8,700 IHHTSF0200
200 IHFKTF4200 6,890 IHFKTW4200 8,990 IHHCD01200
250 IHFSTF4250 7,430 IHFSTW4250 9,700 IHHTSF0250
250 IHFKTF4250 8,110 IHFKTW4250 9,905 IHHCD01250
320 IHFSTF4320 10,315 IHFSTW4320 12,215 IHHTSK0315
320 IHFKTF4320 10,675 IHFKTW4320 12,640 IHHCD02315
400 IHFSTF4400 13,110 IHFSTW4400 14,875 IHHTSMF400
400 IHFKTF4400 12,680 IHFKTW4400 14,435 IHHCD02400
630 IHFSTF4630 21,385 IHFSTW4630 24,405 IHHTLM0630
630 IHFKTF4630 20,150 IHFKTW4630 23,985 IHHCD03630
Switch Disconnector Fuse (Panel Mounting Cubicle Type) Conforms to IS:13947 (Part I & III)Three Pole & Neutral - AC-23A, 50Hz, 415V
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-26
Four Pole - AC-23A, 50Hz, 415V Conforms to IS:13947 (Part I & III)
Four Pole - AC-23A, 50Hz, 415V Conforms to IS:13947 (Part I & III)
Switch Disconnector Fuse Unit
Note:-
* All switch disconnector fuse units if required without fuse link will be made available on request.
* IHFSTO/W 4800 and IHFKTO/W 4800 available without Fuse Link. (Price on request)
Switch Disconnector Fuse Unit
Rating Cat. No. MRP Cat. No. MRP HBC Fuse Amp. Type
Open In Sheet Execution Steel Encl. with 4 Fuses with 4 Fuses
32 IHFDFF4032 2,090 IHFDFW4032 2,745 IHHTIA0032
32 IHFFFF4032 2,670 IHFFFW4032 3,165 IHHCD00032
63 IHFDFF4063 2,640 IHFDFW4063 3,380 IHHTSS0063
63 IHFFFF4063 3,130 IHFFFW4063 3,675 IHHCD00063
100 IHFDFF4100 5,320 IHFDFW4100 6,380 IHHTSD0100
100 IHFFFF4100 5,520 IHFFFW4100 6,485 IHHCD00100
125 IHFDFF4125 5,705 IHFDFW4125 6,805 IHHTSD0125
125 IHFFFF4125 5,985 IHFFFW4125 7,210 IHHCD00125
Rating Cat. No. MRP Cat. No. MRP HBC Fuse Amp. Type
Open In Sheet Execution Steel Encl. with 4 Fuses with 4 Fuses
160 IHFSFF4160 8,165 IHFSFW4160 9,450 IHHTSF0160
160 IHFKFF4160 8,990 IHFKFW4160 9,710 IHHCD01160
200 IHFSFF4200 8,310 IHFSFW4200 9,930 IHHTSF0200
200 IHFKFF4200 9,135 IHFKFW4200 10,225 IHHCD01200
250 IHFSFF4250 9,050 IHFSFW4250 11,345 IHHTSF0250
250 IHFKFF4250 9,905 IHFKFW4250 11,655 IHHCD01250
320 IHFSFF4320 11,920 IHFSFW4320 14,830 IHHTSK0315
320 IHFKFF4320 12,270 IHFKFW4320 15,605 IHHCD02315
400 IHFSFF4400 14,105 IHFSFW4400 16,315 IHHTSMF400
400 IHFKFF4400 13,680 IHFKFW4400 15,730 IHHCD02400
630 IHFSFF4630 24,795 IHFSFW4630 27,795 IHHTLM0630
630 IHFKFF4630 23,685 IHFKFW4630 26,350 IHHCD03630
Switch Disconnector Fuse
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-27
IS Size Tag BS Rated Breaking Rating Cat No. MRP STD
Type Type Voltage Capacity (Amps) Packing
(Volts) (kA)
2 IHHNS00002
4 IHHNS00004
6 IHHNS00006 40 20
10 IHHNS00010
F-1 Offset NS 415 80 16 IHHNS00016
20 IHHNS00020
25 IHHNS00025 45 20
32 IHHNS00032
6 IHHTIA0006
10 IHHTIA0010
16 IHHTIA0016
A-2 Offset TIA 415 80 20 IHHTIA0020 58 10
25 IHHTIA0025
32 IHHTIA0032
36 IHHTSS0036
A-3 Offset TSS 415 80 50 IHHTSS0050 70 10
63 IHHTSS0063
80 IHHTSD0080
A-4 Offset TSD 415 80 100 IHHTSD0100 155 10
125 IHHTSD0125
80 IHHTSDC080
B-1 Central TSDC 415 80 100 IHHTSDC100 155 10
125 IHHTSDC125
125 IHHTSF0125
B-2 Central TSF 415 80 160 IHHTSF0160 225 10
200 IHHTSF0200
250 IHHTSF0250 255 10
225 IHHTSK0225
B-3 Central TSK 415 80 250 IHHTSK0250 330 3
300 IHHTSK0300
315 IHHTSK0315
B - 4 Central TSMF 415 80 400 IHHTSMF400 640 3
C - 1 Central TSMS 415 80 400 IHHTSMS400 640 3
C - 2 Central TTS 415 80 400 IHHTTS0400 715 1
500 IHHTTS0500
C - 2 Central TTM 415 80 400 IHHTTM0400 970 1
500 IHHTTM0500
C - 2 Central TLM 415 80 630 IHHTLM0630 1,295 1
HBC Fuse Links
HBC Fuse Link
Bolted Type
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-28
HBC Fuse Links
IS Size Rated Breaking Rating Cat No. MRP STD
Voltage Capacity (Amps) Packing
(Volts) (kA)
6 IHHCD11006
10 IHHCD11010
16 IHHCD11016 165 3
20 IHHCD11020
25 IHHCD11025
000 415 80 32 IHHCD11032
40 IHHCD11040
50 IHHCD11050
63 IHHCD11063 170 3
80 IHHCD11080
100 IHHCD11100
6 IHHCD00006
10 IHHCD00010
16 IHHCD00016
20 IHHCD00020
25 IHHCD00025
32 IHHCD00032
00 415 80 50 IHHCD00050 200 3
63 IHHCD00063
80 IHHCD00080
100 IHHCD00100
125 IHHCD00125 260 3
160 IHHCD00160 275 3
32 IHHCD01032
63 IHHCD01063
80 IHHCD01080 400 3
01 415 80 100 IHHCD01100
125 IHHCD01125
160 IHHCD01160 415 3
200 IHHCD01200
250 IHHCD01250 475 3
200 IHHCD02200
250 IHHCD02250 625 1
02 415 80 315 IHHCD02315
350 IHHCD02350 655 1
400 IHHCD02400
425 IHHCD03425 925 1
03 415 80 500 IHHCD03500 950 1
630 IHHCD03630
Rated Breaking Rating Cat No. MRP STD
Voltage Capacity (Amps) Packing
(Volts) (kA)
2 IHHRH00002
4 IHHRH00004 60 20
6 IHHRH00006
10 IHHRH00010
16 IHHRH00016
415 80 20 IHHRH00020
25 IHHRH00025 65 20
32 IHHRH00032
40 IHHRH00040
50 IHHRH00050 120 20
63 IHHRH00063 135 20
HBC Fuse Link
DIN Type
RH Type
Industrial SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-29
Fuse Holders & Fuse Bases
Nylon Fuse Bases
Rating Cat. No. Type Fuse MRP STD.Amp. Type Packing
160A IHMC00O160 Open Type Fuse Base CD000/00 225 6
250A IHMC01O250 Open Type Fuse Base CD01 410 3
400A IHMC02O400 Open Type Fuse Base CD02 570 3
630A IHMC03O630 Open Type Fuse Base CD03 770 3
Cat. No. Description Fuse MRP STD. Type Packing
IHVONSH020 20A HRC FF Cam Lock Front Connection HNS 90 12IHVTIAH032 32A HRC FF Cam Lock Front Connection HTIA 150 6IHVTSSH063 63A HRC FF Cam Lock Front Connection HTSS 185 3IHVTSDH100 100A HRC FF Cam Lock Front Connection HTSD 455 3
IHVONSB020 20A HRC FF Cam Lock Bus Bar Connection HNS 90 12IHVTIAB032 32A HRC FF Cam Lock Bus Bar Connection HTIA 150 6IHVTSSB063 63A HRC FF Cam Lock Bus Bar Connection HTSS 185 3IHVTSDB100 100A HRC FF Cam Lock Bus Bar Connection HTSD 455 3
IHVONSR020 20A HRC FF Cam Lock Rear Connection HNS 90 12IHVTIAR032 32A HRC FF Cam Lock Rear Connection HTIA 150 6IHVTSSR063 63A HRC FF Cam Lock Rear Connection HTSS 185 3IHVTSDR100 100A HRC FF Cam Lock Rear Connection HTSD 455 3
Cam Lock Fuse Bases
Open Type DMC Fuse Base
Rating Cat. No. Type Fuse MRP STD.Amp. Type Packing
100A IHUC00O100 Open Type Fuse Base CD-00 205 6
125A IHUC00O125 Open Type Fuse Base CD-00 230 6
160A IHUC00O160 Open Type Fuse Base CD-00 235 6
250A IHUC01O250 Open Type Fuse Base CD-1 420 3
400A IHUC02O400 Open Type Fuse Base CD-2 640 3
630A IHUC03O630 Open Type Fuse Base CD-3 820 3
Fuse LinkFuse Links Porcelain Rewireable Conforms to IS:2086
Amps/ Cat. No. MRP STD.Volt Packing
16/240 IHKKRN2016 65 2016/415 IHKKRN4016 125 2432/240 IHKKRN2032 125 2432/415 IHKKRN4032 150 1263/415 * IHKKRN4063 250 1263/415 # IHKKDN4063 285 6100/415 * IHKKRN4100 460 6100/415 # IHKKDN4100 520 1200/415 * IHKKRN4200 915 1200/415 ** IHKKRT4200 1,125 1320/415 * IHKKRN4320 1,425 1320/415** IHKKRT4320 1,675 1
* - Std., # - Dlx, ** - With Extension strips
Conventional SwitchgearMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & ConditionsMaximum Retail Prices (MRP) are in Indian Rupees
as per Regular Terms & Conditions
Effective from 1st July, 2009
IP-30IP-30
Load Changeover Switches
Current No. of Cat. No. MRP Rating Ways
Wall Mounted
100A 4 WAy IHBB010004 8,590 6 WAy IHBB010006 11,830 8 WAy IHBB010008 12,530
200A 4 WAy IHBB020004 9,590 6 WAy IHBB020006 12,830 8 WAy IHBB020008 13,530
250A 4 WAy IHBB025004 14,500 6 WAy IHBB025006 23,500 8 WAy IHBB025008 32,500
315A 4 WAy IHBB031504 15,000 6 WAy IHBB031506 24,000 8 WAy IHBB031508 33,000
400A 4 WAy IHBB040004 16,000 6 WAy IHBB040006 25,000 8 WAy IHBB040008 34,000
630A 4 WAy IHBB063004 23,350 6 WAy IHBB063006 33,800 8 WAy IHBB063008 50,000
800A 4 WAy IHBB080004 24,350 6 WAy IHBB080006 34,800 8 WAy IHBB080008 51,000
Busbar Chambers
General Purpose Load Changeover SwitchesConforms to IS:13947 (Part I & III)
Onload Changeover Switch - AC 23 (side handle)in sheet enclosure, 415V.
Rating Cat. No. MRP
Amp.
Double Pole
32 IHCFDE0032 1,195
Triple Pole
32 IHCFTE0032 1,740
63 IHCFTE0063 3,435
100 IHCFTE0100 6,490
Four Pole
16 IHCFFE0016 1,745
32 IHCFFE0032 2,095
63 IHCFFE0063 4,265
100 IHCFFE0100 8,575
200 IHCFFE0200 12,265
320 IHCFFE0320 15,575
400 IHCFFE0400 20,350
630 IHCFFE0630 31,230
800 IHCFFE0800 38,935
1000 IHCFFE1000 51,485
1250 IHCFFE1250 1,16,625
1500 IHCFFE1500 1,34,610
2000 IHCFFE2000 1,89,465
Offload Changeover Switch- AC 21 (side handle)in sheet enclosure, 415V.
Maximum Retail Prices (MRP) are in Indian Rupees as per Regular Terms & Conditions
Conventional SwitchgearSwitch Fuse Units / Fuse Switches
Heavy Duty Double Break Fuse Switches - HBC Fuse type415V Conforms to IS:13947 (Part I & III)
The above prices are inclusive of 3 nos. HBC Fuse Links.
* Switch suitable for 800 Amp. but fitted with 630 Amp. Fuse.All the Switches are surface mounting type, housed in sheet steel enclosure with side handle operation and have front access left opening doors interlocked to prevent opening when the switch is in on position.
Rating Cat. No. MRP Cat. No. MRP Fuse Type
Triple Pole Four Pole with & Neutral Switched Neutral
63 IHFNTW4063 4,885 IHFNFW4063 6,095 IHHTSS0063
100 IHFNTW4100 6,620 IHFNFW4100 8,525 IHHTSD0100
200 IHFNTW4200 9,500 IHFNFW4200 12,710 IHHTSF0200
320 IHFNTW4320 11,925 IHFNFW4320 15,605 IHHTSK0315
400 IHFNTW4400 18,245 IHFNFW4400 25,330 IHHTSMF400
500 IHFNTW4500 25,780 — — IHHTTM0500
800* IHFNTW4800 32,140 — — IHHTLM0630
General Purpose Switch Fuse Units / Fuse SwitchesSwitch Fuse Units (Rewireable Type)
Conforms to IS:13947 (Part I & III)
Single Pole & Neutral / Double Pole
Amp. / Cat. No. MRPVolt
Single Pole & Neutral
16/240 IHSRSE2016 360
32/240 IHSRSE2032 950
63/415 IHSRSE4063 2,310
Double Pole
16/240 IHSRDE2016 370
32/240 IHSRDE2032 1,025
63/415 IHSRDE4063 2,665
Triple Pole, 415V, with Neutral Link
Rating Cat. No. MRP Cat. No. MRP Cat. No. MRP Suitable Amp. Fuse* Type
With With HBC cum With Bakelite Rewireable rewireable Fuse Fittings Porcelein Porcelein (without HBC* Fuse Units Fuse Units Fuse links)
16 IHSRTE4016 1,085 IHSHTE4016 1,085 IHSBTE4016 1,085 IHHNS0016
32 IHSRTE4032 1,505 IHSHTE4032 1,505 IHSBTE4032 1,505 IHHTIA0032
63 * IHSRTE4063 3,145 — — — — —
63 # IHSDTE4063 3,350 IHSHTE4063 3,350 IHSBTE4063 2,510 IHHTSS0063
100 * IHSRTE4100 5,855 — — — — —
100 # IHSDTE4100 6,140 IHSHTE4100 6,140 IHSBTE4100 6,140 IHHTSD0100
200 IHSRTE4200 9,500 — — — — —
320 IHSRTE4320 13,120 — — — — —
* - Std, # - Dlx
Effective from 1st July, 2009
IP-31
Loadbank is a power distribution board with MCCBs as incoming and outgoing
switching-cum-protective devices, for distribution of power to various loads
as per the requirements of the system.
The modular construction of load bank renders the customary panel building
redundant by virtue of compactness, reduced cost and short delivery time
coupled with reliability of the various modular units. All units are fabricated using
sheet steel of 1.6mm and are epoxy powder coated to give a superior finish.
Range :
Two basic versions :
• ’G’framepanelboardsupto400A
• ‘A’framepanelboardsupto800A.
Features :
• Readymade&customisedsolutionsforloadmanagement
• Modular construction & compact size provides economy of space,
time & cost.
• Designedforfloormounting/wallmounting
• Speciallydesignedshroundedbusbarprovidessafety
• No.ofwaysoptionpermitsfuturesystemexpansion
• Easy add on modules to house various devices offers simplicity
& flexibility
• Elegant&sleekinappearance.
Specification :
• Fullyapplicationorientedasper
• IS:13947-I&IIandIEC:60947-I&II
• IS:8623andIEC60439
• IS:2147andIEC:60529.
“Titania” range of Air Circuit Breakers are available from 630 A to 4000 A
rating in 2-3 and 4 pole execution, with breaking capacity of 50kA to 100kA.
These ACBs have been designed keeping in mind the present day complex
requirement of electrical systems which makes it essential to have a reliable
product which can give un-interrupted service through out the product life
meeting all the stresses that the system encounters.
These ACBs are most compact in size. The height, depth and panel door
cut out are same through out the range. The accessories are common for
the entire range and are front accessible, easy to fit without the need for
cabling.
Features:
• Compactsize,widerange&highbreakingcapacity
• 630Ato4000Aavailableinonly3framesizes
• Firstframeavailableupto2000A
• Commonheight,depthandpaneldoorcutout
• Frontaccessibleaccessorieswithoutrequiringany internal cabling at site
• Commonaccessoriesfortheentirerange
• Modularconstructionforpoleunit
• Easilyreplaceablearcingcontacts
• Availablewithcommunicationfacility