7/29/2019 ION Enterprise 6.0
1/8
Gain energy insight and
control with PowerLogic
PowerLogic ION Enterprise
power management software
-
7/29/2019 ION Enterprise 6.0
2/8
PowerLogic ION Enterprise is a complete power
management solution or energy providers and
industrial or commercial operations. It helps
engineering and management personnel cut
energy-related costs, avoid downtime and
optimise equipment utilisation.
The sotware uses industry-standard network
technologies, including Ethernet and wireless,
to automatically collect and store data rom
key electrical distribution points and physical
assets. It orms a layer o energy intelligence
across your acility, campus, service area or your
entire enterprise, acting as a unifed interace
to electricity and other consumable resources
such as water, compressed air, gas and steam.
Web-enabled monitoring and reporting gives
each user personalised access to timely, relevant
inormation.
PowerLogic ION Enterprise tracks real-time power
conditions, analyses power quality and reliability,
and responds quickly to alarms to avoid critical
situations. It helps you study trends to reveal
energy waste or unused capacity as well as veriy
efciency improvements and allocate costs to
buildings, departments or processes.
The sotware includes sophisticated load
aggregation and arithmetic calculation.
Coordinated control capabilities can be used
to manage demand or power actor and to
manage loads or generators. Customised
inormation is easily and seamlessly shared with
all stakeholders and with other business and
automation systems.
Manage real-time power conditions and energy efficiency
Solution overview
Corporate network
Historical trend
analyses
Alarms and control
functions
Real-time display
of data Power quality
analyses
Customised
reporting
Switching and
mitigation equipment
Power distribution
equipment
Loads, processes
or tenants
Incoming power feeds
and on-site generation
Local and remote workstations
-
7/29/2019 ION Enterprise 6.0
3/8
PowerLogic ION Enterprise is the ideal power management sotware
tool or data centres and other operations with critical power needs, largeand small industrial acilities, and commercial buildings o all kinds. Its a
solution that provides eective data acquisition, energy savings, avoidance
o utility penalties, and overall improved efciency and productivity.
Typical applications of PowerLogic ION Enterprise
Energy efficiency and cost
vReduce peak demand surcharges
vReduce power actor penalties
vEnable participation in load curtailmentprograms (e.g. demand response)
Power availability and reliability
vValidate that power quality complies with the
energy contract
vVeriy the reliable operation o equipment
vImprove response to power quality-related
problems
vLeverage existing inrastructure capacity and
avoid over-building
vSupport proactive maintenance to prolong
asset lie
Power availability and reliability
vImprove T&D network reliability
vEnhance substation automation
vMaximise the use o existing inrastructure
vVeriy compliance with new power quality
standards
vAnalyse and isolate the source o power quality
problems
vHelp customers manage reliability using
operational and power quality data
Applications for critical infrastructure,
industry, and buildings
Applications for electric utilities
-
7/29/2019 ION Enterprise 6.0
4/8
10:46
November
OPCOPC
Software architecture
Data presentation
Enterprise-wide, multi-user data and control access
through local server interace, thin-client web browser,or terminal services; tiered security
Inormation and alerts via mobile phone,
PDA and other devices
v
v
Functional components (on main server or workstations)
Management Console confgure your PowerLogic ION Enterprise network,
including communication paths, devices and logical groups.Designer customise the modular unctionality o ION devices
and Virtual Processors (see below)
Vista real-time displays o measurements and status indicators,
power quality analysis, historical trending, alarms and manual control
Web Reporter predefned or custom reports; support or third-party reporting tools
v
v
v
v
Data acquisition and management
Virtual Processor - multi-site aggregation, coordinated control, complex calculations and alarming,
logging or non-recording devices (e.g. interval kWh)
Site Server - continuous or scheduled retrieval o data rom up to hundreds o remote devices
over Internet, Ethernet, telephone, serial, wireless, or satellite connections
SQL ODBC-compliant databases - Microsot SQL Server 2005 (with support o SQL Server 2000).Log device data, system data and events with accurate meter synchronisation (16 ms or 1 ms using GPS)
or precise event timestamping, power quality analysis and revenue billing; data is securely accessible
using industry-standard database tools; add distributed databases and servers as required or load balancing
OPC DA Client (standard), OPC DA Server (optional) and PQDIF Exporter (optional)
supports data import/export with compliant devices and systems
v
v
v
v
Management Console Designer Vista Web Reporter
Virtual Processor Site Server Database OPC DA
Global Access Local Workstations Remote Workstations Wireless Alerts
DataPresentation
FunctionalComponents
Data Acquisition& Management
-
7/29/2019 ION Enterprise 6.0
5/8
Data acquisition and integrationvIntegrate metering o WAGES (water, air, gas, electricity, steam)
vProvide standard product native support or PowerLogic ION series, PM800 series, PM700 series,
PM210, CM3000 series, CM4000 series and legacy ACM series power and energy meters
vAccess all real-time and logged data, control on-board relays and digital outputs,
remote confguration and frmware upgrading
vSupport data access rom the CM2000 Series, PM600 Series, PM9C, PM500, MCM, Model 98
Transormer Temperature Controller, Enercept Meter, Energy Meter, and BCM42
vEasily add support or third-party meters, transducers, PLCs, RTUs and power distribution or
mitigation equipment
vQuickly add and confgure remote device communication over Modbus RTU or Modbus TCP protocols
vUse MeterM@il to securely access meter data via Internet within frewall restrictions
vAdd devices and user clients to the scalable platorm as needs grow
vIntegrate other energy management or automation systems (e.g. SCADA, BAC, DCS, ERP) through
ODBC, XML, OPC, email, FTP, CSV and PQDIF compliance; integrate web services via XML
Scalable, flexible architecturevGrow to hundreds o metering points
vAdd distributed servers and clients
v
Use modular programming or complexprocessing and control
vIntegrate legacy and third-party devices
vLeverage and optimise existing inrastructure
Real-time monitoringvCollect system-wide data
vPerorm calculations, display and log derived data
vCustomise views o data digital igures, dials, bar
or trend graphs, one-line diagrams, etc.
vCommunicate over Internet, Ethernet, wireless
InteroperabilityvIntegrate all energy management and automation
systems
vShare data with third-party SCADA, automation,
and accounting systems
vComply with ODBC, OPC, and PQDIF standards
-
7/29/2019 ION Enterprise 6.0
6/8
Reporting
The powerul, intuitive Web Reporter module lets users seecritical inormation exactly how, where, and when they need it.
vPreconfgured or ully customised
vSupports third-party reporting tools and export data to MS Excel
vManual, scheduled, or alarm/event-triggered distribution
via email or web
vCombine databases to reveal true business conditions
vReports accessible via a Web browser
vSupport WAGES (Water, Air, Gas, Electrical, & Steam)
measurements
vPer user security model (View, Edit, Create, and Delete)
vCan be generated in PDF ormat
vCan export data in XML ormat
vSupport remote report development and uploading
Includes:
vEnergy Period over Period Comparison (Compare energy
consumption o dierent periods)
vEnergy by Shit Report (Compare energy over dierent
user-defned shits)
vTrending Report (Trend multiple measurements or one deviceor one measurement or multiple devices over time)
vTabular Report (Show logged measurements and
associated time in a raw tabular ormat)
vAlarm & Event Report (Show events/alarms rom
specifc devices based on priority level)
vSystem Confguration Report (a quick system inventory
Device Name, Group, Connection, and Device Address)
v100 Millisecond Report (Show Power Quality millisecond
time-stamped data rom devices supporting millisecond
logging o PQ measurements
vIEC61000-4-30 and EN50160 Power Quality reports
vEnergy cost Report (associate rates with TOU schedule to
generate total cost data)
Trends and analysis
Trend any parameter to reveal demand
peaks and track system-wide energy costs
vGraph any combination o measured parameters
vAggregate loads
vIdentiy dangerous trends and redistribute loads
vOptimise network capacity, avoid over-building
vAvoid peak demand surcharges and power actor
penalties
Power quality analysis
vMonitor events and waveorm plotting
system-wide
vMonitor harmonics, K-actor, crest actor,
symmetrical components
vDiagnose and isolate PQ problems to
increase reliability
vBenchmark perormance and compareservice areas
vTrack contracted service compliance
-
7/29/2019 ION Enterprise 6.0
7/8
Web portal
vAllow multi-user access
vUse multi-level security checks
Alarms and events
vTrigger on complex conditions
vGenerate & distribute alarm notifcations
vLog all relevant data sequence o events
or diagnosis
vFlag and avert potential problems
vAlert key personnel 24/7
vOptimise maintenance scheduling
Manual and automated
controlvPerorm manual or setpoint-triggered unctions
vCoordinate control o multiple loads,
generators, relays, etc.
v
Support energy-saving applicationsvManage distributed energy assets
vAutomate substations & reduce service time
-
7/29/2019 ION Enterprise 6.0
8/8
Please contact your local sales representative or ordering inormation.
Visit www.powerlogic.com or more inormation on other PowerLogic products,
applications and system solutions.
Enhance your PowerLogic solutionSupport or expand your PowerLogic solution with matched accessories and
complementary products or systems. Integrate with other Schneider Electric
products or with third-party products through industry-standard protocols.
PowerLogic EGX Ethernet gateways
Access devices on downstream serial networks through ast Transparent
ReadyEthernet communications eaturing customised web pages.
PowerLogic ION7550, RTU optionRemote terminal unit or transducer and equipment monitoring.
T1 current transformers
Ratio o lp/5 or use with measurement devices, relays, etc.
Sepam protective relays
Monitoring, protection and control o substations, busbars, transormers,
motors, generators and capacitors.
Masterpact and Compact breakers
Equipped with Micrologic control units, oering protection or LV networks.
Modicon programmable logic controllers
Small-scale distributed control to robust, powerul stand-alone PLCs.Altivar variable frequency drives
Match motor output to required loads to reduce energy consumption
and extend motor lie.
Tesys motor controllers
Motor branch short-circuit protection, manual disconnect, remote power
circuit switching and thermal overload protection.
Talus substation control units
Telecontrol, remote monitoring and automatic control o MV substations.
Power factor correction and harmonic filtering solutions
Varplus capacitors, Varlogic controllers, detuned reactors, Varpact
modules, Varset cubicles, Accusine flters and much more.
PowerLogic ME series panel meters
Class 1 accuracy kilowatt-hour panel meters or stand-alone applications.
ServicesOur extensive engineering and support services ensure you leverage the
ull capabilities o your PowerLogic solution and beneft rom a low total
cost o ownership. Our experts can help with system selection, project
management, integration, custom reporting, documentation and training to
meet your organisations unique needs.
Features Standard Optional
Automated data
acquisition rom sites/devices