8/10/2019 IOMCR Alarm List-0831
1/130
CodeLeve
lAlarm Title Alarm Causes
2 2 Optical module signal loss 1. The fiber between near-end Tx and far-end i
256 3 Ethernet link broken Ethernet controller's physical link off alarm
512 1 Trunk LOF Trunk frame loss
513 1 Trunk LOS Trunk signal loss
514 1 Trunk AIS Trunk alarm indication515 1 Trunk LOCMF Trunk multiframe loss
516 1 Trunk RCMAI Far end CRC multiframe alarm indication
517 1 Trunk RAI Far end alarm
518 3 CSU test trunk Unit A transmit CSU Loop Up Code to uint B, so u
576 5 Trunk SLIP BSC,MGW,MGW_C,MSCE,MSCServer,rnc,tdrnc
832 5 Global underflow Global underflow happened
833 5 Global overflow Global overflow happened
1024 4 ATM OCD Cell delimiter cannot synchronize
1025 4 ATM LCD Cell delimiter loss
1280 3 8 kHz input clk loss 8 kHz input clock loss
1281 3 16 MHz input clk loss16 MHz input clock loss
1282 3 PP2S input clk loss PP2S input clock loss
1283 3 32 MHz clk lost at TSNB 32 MHz clock lost in TSNB
1284 3 8 kHz,16 MHz input clock mismatc 8 kHz,16 MHz input clock mismatch
1285 3 CLK chip in pre-heated state Board reset, SETS needs to be pre-heated
1600 5 Board abnormal reset Board abnormal reset
1792 3 SDH/SONET: LOS(Loss of Signa Far end transmitter failure, optical path break, or near e
1793 2 SDH/SONET: LOF(Loss of Fram Out of frame occurs if valid framing pattern (A1,A2) is n
1794 2 SDH/SONET: RS-TIM(Regenerato When the accepted regenerator section trace ide
1795 2 SDH/SONET: MS-AIS(Multiplexing When a 111 binary pattern is detected in bits 6, 7,
1796 3 SDH/SONET: MS-FERF(Multiplexi When a 110 binary pattern is detected in bits 6, 7,
1797 3 SDH/SONET: SF(Signal Failure) When the bit error rate exceeds 1e-3 in the multip
1798 3 SDH/SONET: SD(Signal DeterioratWhen the bit error rate exceeds 1e-6 in the multip1799 2 SDH/SONET: AU-LOP(AdministratiIf there are no valid pointers detected in receiving
1800 2 SDH/SONET: AU-AIS(Administrati When an all 1s pattern is detected in the payload
1801 2 SDH/SONET: HP-TIM(Higher orde When the accepted VC-4 path trace identifier me
1802 2 SDH/SONET: HP-UNEQ(Higher or When the VC-4 path signal label indicates unequi
1803 2 SDH/SONET: HP-PLM(Higher ordeWhen the VC-4 path signal label differs from the
1804 3 SDH/SONET: HP-FERF(Higher ordWhen bit-5 of byte G1 is set to 1 in the receiving
1805 2 SDH/SONET: LOM(Loss of MultifraWhen there are no valid multi-frame codes detect
1806 4 SDH/SONET: TU-LOP(Tributary U If there are no valid TU pointers detected in recei
1807 4 SDH/SONET: TU-AIS(Tributary Un When an all 1s pattern is detected in the tributary
1808 4 SDH/SONET: LP-RDI(Lower order When bit-8 of byte V5 is set to 1 for 5 consecutive
1809 4 SDH/SONET: LP-RFI(Lower order When bit-4 of byte V5 is set to 1 for 5 consecutive1810 4 SDH/SONET: LP-TIM(Lower order When the accepted TU trace identifier message (
1811 4 SDH/SONET: LP-UNEQ(Lower ordWhen the VC-12 path signal label indicates uneq
1812 4 SDH/SONET: LP-PLM(Lower order When the VC-12 path signal label differs from the
1814 2 Higher order path signal failure If the incoming error rate exceeds the thresholds
1815 3 Higher order path signal deteriorati If the incoming error rate exceeds the thresholds
1816 2 SDH/SONET: Excessive B1 error SDH/SONET: Excessive B1 error
-
8/10/2019 IOMCR Alarm List-0831
2/130
1817 2 SDH/SONET: Excessive B2 error SDH/SONET: Excessive B2 error
1818 2 SDH/SONET: Excessive B3 error SDH/SONET: Excessive B3 error
1819 4 SDH/SONET: Excessive BIP-2 erroSDH/SONET: Excessive BIP-2 error
1820 2 SDH/SONET: Multiplexing seDeclared when higher order path block e
1821 2 SDH/SONET: VC-4 far end e Declared when higher order path block e
1822 2 SDH/SONET: Higher order p When the bit error rate exceeds 1e-3 in t1823 1 SDH/SONET: Higher order p When the bit error rate exceeds 1e-6 in t
1856 5 APS Change APS switching events
2048 3 E3S subcard transmit directioTransmitter loss of signal is asserted wh
2049 3 E3S subcard receive directio Receiver loss of signalis asserted when a conti
2050 3 Out of frame In DS3 mode, out of frame is asserted if t
2051 3 E3S subcard receive alarm siAIS is asserted when AIS pattern is recei
2052 3 Remote error indication Remote error indication is asserted when
2560 2 CPU usage above threshold CPU usage rate may be too high, when operation
2561 2 CPU temprature above threshold Warning when any CPU temperature is too high
2624 5 Stack overflow The stack that this process uses has exceeded the thre
3072 2 Hard disk initialization failure 1. Hard disk physical damage 2. Hard disk can be3073 2 FLASH device initialization failure FLASH device failed to initialize
3136 5 Disk is full Notify the OAM agent that disk is full when the disk is f
3393 5 Predefined timer not set Board not rebooted after addition of pred
5120 1 Fibre connection error UIM TFS prot connect to TFI doesnt match with
5121 3 GE link error GE link error
5122 3 Control layer communication error 1. Board backup mode is Master and Slave, but
5123 3 Database configuration not compatiDatabase configuration not compatible with hard
5124 3 Trunk link error Physical FE link or port setting error
5187 5 GLI port configuration mismatch GLI port configuration does not match, the assign
5188 5 UIM CS changeover Exchange key pushedENUM opened
5189 5 Master and slave changeover Master and slave changeover
5190 5 Fast Ethernet connection error FE port state changed from up to down.
5193 5 Basic process power supply inform 1) All basic processes finished powering 2) A cert
5376 2 Media port error The state of the inner media port is link down
5378 2 RSMM HW loop error 1. HW between board and UIM error 2. Clock abn
5379 2 Board does not exist Board is not at position or CPU resets abnormally
5381 2 Input clock abnormal CLKG work mode abnormal with input clock abno
5382 2 PWRD 485 communicate link brok PWRD and OMP communication link broken bec
5383 2 Bureau number inconsistent Bureau number in database does not match the o
5384 2 Area number inconsistent Area number in database does not match the one
5385 2 OMC MAC address inconsistent OMC MAC in database does not match the one in
5386 2 OMC IP address inconsistent OMC IP in database does not match the one in b
5387 2 MP type inconsistent MP type in database does not match the one in b5388 2 Bootcfg.ini does not exist bootcfg.ini does not exist
5389 4 A CPU subcard is detected but not A CPU subcard is detected but not configurated b
5390 2 A CPU subcard is configured in datA CPU subcard is not detected but has been conf
5391 2 OMP Gateway IP in BootCfg.ini inc OMP Gateway IP in database does not match the
5392 2 OMC Server IP in BootCfg.ini inconOMC Server IP in database does not match the o
5393 2 OMC Gateway Net Mask in BootCf OMC gateway Net Mask in database does not ma
-
8/10/2019 IOMCR Alarm List-0831
3/130
5394 1 Change in OMP configuration OMP configuration changed, need to restart man
5395 2 External port status is down External port status is down
5396 2 Internal media VLAN commu Internal media VLAN communication abn
5441 5 HSSL break off between GLI and P GLI port state changed
5448 5 Set up 485 offline failure Hardware or C51 software problem
5632 1 The threshold alarm of IDE use roo Hard disk usage rate above the threshold value
5633 1 Board IDE ERROR Board hard disk error
5634 3 Trunk port down Trunk line or bcm5615 port malfunction
5635 1 ENUM open ENUM open
5636 1 SMBUS error Reset board while reading or writing device SMB
5637 1 Front and rear board mismatch Front and rear board mismatch
5638 2 Non-frequent loss of LVDS signal l LVDS signal lock lost
5639 2 Non-frequent high error code rate The rate of error code in a fiber is high
5640 2 FPGA is abnormal FPGA version is abnormal. It happens only once.
5641 3 DSP port link down lan91 chip fault or bcm5328 chip fault
5642 2 Hard disk reliability low Raw Read Error Rate, Start/Stop Count, Seek Err
5643 3 PLL Work Mode changed PLL work in free.
5644 3 The channel in a subcard is down The channel in a subcard is always down after it h5645 1 Subcard abnormal Subcard abnormal
5646 1 PLL lock lost Phase Locked Loop lock lost
5647 1 E1 link high error code rate E1 link or the uplink device has fault
5650 1 Board MAC address conflict Board is not in its correct position or othe
5651 1 OSS detection of board IP anBoard is not in its correct position or othe
5652 1 Class A error of SETS Class A error of SETS
5655 2 DSP check abnormal DSP port status is abnormal, more than t
5700 5 DSP operation failure DSP operation failure
5701 5 Loading failure Version loading failure
5705 5 MCU operation failure MCU cannot perform normal handshake operatio
5706 5 External port work mode not External port work mode not supported b5707 5 Tone file system initialization failure Illegal data in Flash, file systum initialization failure
5889 4 Version switching information Switch the existing version for OMP, user can res
5890 4 EPLD upgradation failure (1) EPLD version too large (limited to 64K); (2) E
5891 4 BOOT/EPLD upgrade inform (1) Running BOOT version not consisten
5892 4 BOOT version synchronizatioBackup bootflash failure
5956 5 Peripheral board version erro Peripheral board cannot get its version fil
5958 5 IDE version synchronization i 1. IDE file synchronization complete; 2.
6400 3 Cx29704 status error The Status of Cx29704 is ERR
6720 5 C51 board power-on state noC51 board power-on succeed
8000 5 Database tables load failure There is abnormal data, data loading abo
8003 5 MP-PP synchronization failur MP requests PP for data synchronization8004 5 Data table saving failure When the table structure disagrees with t
8006 5 Data configuration change n If the times of sending message goes be
8007 5 Saving file failure in master o 1. Disk is full 2. Disk error
8010 5 Multi-CPU module, board typ Multi-CPU board, unit type in r_unit must
8011 5 Database failure 1. System initialization failure; 2. Loading
10304 5 SCCP GT translation failure The called address has: 1. No signalling point cod
-
8/10/2019 IOMCR Alarm List-0831
4/130
-
8/10/2019 IOMCR Alarm List-0831
5/130
19264 5 IMA Group related operation failur When the group operation originated by the OMC
19265 5 IMA link related operation failure When the link operation originated by the OMC s
19456 1 All HSSLs are out of synchronizatioAll HSSLS are out of synchronization, it is possibl
19520 5 Some HSSLs are out of synchroniz Some HSSLS are out of synchronization because
19521 5 Sframe mode error is serious May be due to a fault on VSC872 chip
19522 5 Cframe lost because of horizontal cMay be due to a fault on VSC872 chip
19523 5 Cframe lost because of vertical cheMay be due to a fault on VSC872 chip
19524 5 Cframe lost because of no integrity May be due to a fault on VSC872 chip
19525 5 Cframe lost because of invalidity May be due to a fault on VSC872 chip
19526 5 Cframe lost due to invalid length May be due to a fault on VSC872 chip
19527 5 Frame lost due to out of order May be due to a fault on VSC872 chip
19528 5 Frame lost due to CRC check error May be due to a fault on VSC872 chip
19529 5 IXP2400 configuration failure IXP2400 configuration fails because TM process
19530 5 VSC872 configuration failure VSC872 configuration fails because TM process
19712 2 Automatic Protection Switching chaFar end and Near end configurations are inconsis
19713 2 Automatic Protection Switching mo Far end and Near end configurations are inconsis
19714 2 APS replacement board 1. APS board cofigured as 1+1, but board mode i
19968 2 L2fwdtbl failure to get information frDatabase does not respond to UIM's request for19969 2 L2fwdtbl failure to get information SCS does not respond to UIM's request for L2fwd
19970 2 Resource board can not get L2FW UIM warns when it has not got L2fwdtbl informatio
20032 5 L2fwdtbl initialization failure L2fwdtbl initialization failure
20033 5 L2fwdtbl initialization UIM Ethernet L2fwdtbl initialization UIM Ethernet port failure
20288 5 BRS main configuration request timProtocol process does not receive acknowledgme
20289 5 BRS main RPU registeration timeo EPU does not receive acknowledgment three tim
20290 5 BRS protocol process fatal failure Protocol failure because it did not receive correct
20800 5 ARP memory instance allocation fa Unable to allocate memory for ARP entries
20801 5 ARP cache memory allocation failu Unable to allocate memory for ARP cache
20802 5 IP address collision with another m IP address collision with another machines IP ad
20803 5 Duplicate MAC address found in thAppears when setting the duplicate MAC address
21066 5 RIP instance creation failure RIP failed to allocate memory
22784 3 BFD session is Down The connectivity between the systems fail
22848 5 BFD session configuration failure BFD configuration is incorrect or the BFD does no
25600 4 Connection check be closed. switch of Connection Check be turned off.Connec
25664 5 Half-fixed connection is changed a Input clock is not stable or hardware fault
25665 5 Fixed connection configuration data Fixed connection configuration data has error
25856 3 Rack temperature above the high t Temperature reported is above the high threshold
25857 3 Rack temperature below the low thrTemperature reported is below the low threshold
25858 3 Room temperature above the high tTemperature reported is above the high threshold
25859 3 Room temperature below the low thTemperature reported is below the low threshold
25860 3 Voltage above the high threshold Voltage reported is above the high threshold
25861 3 Voltage below the low threshold Voltage reported is below the low threshold25862 3 Humidity above the high threshold Room humidity reported is above the high thresho
25863 3 Humidity below the low thres Room humidity reported is below the low
25864 3 Fan alarm Fan state is different from the former
25865 3 Door alarm Door state is different from the former
25866 3 Smoke alarm Smoke in the room
25867 3 Infrared alarm Infrared detection alarm
-
8/10/2019 IOMCR Alarm List-0831
6/130
25868 3 Lightning alarm Lightning alarm
26112 2 CLKG 32M output clock lost CLKG 32M output clock lost
26113 2 CLKG 32M8K output clock lost CLKG 32M8K output clock lost
26114 2 CLKG 16M output clock lost CLKG 16M output clock lost
26115 2 CLKG 16M8K output clock lost CLKG 16M8K output clock lost
26116 2 CLKG PP2S output clock lost CLKG PP2S output clock lost
26117 2 CLKG PP2S clock base lost CLKG PP2S clock base lost
26118 2 CLKG clock 16CHIP base lost CLKG clock 16CHIP base lost
26119 2 All clock bases lost All clock bases set in database are lost
26120 3 CLKG I2MB0 clock base lost CLKG I2MB0 clock base lost
26121 3 CLKG I2MB1 clock base lost CLKG I2MB1 clock base lost
26122 3 CLKG I2MHZ0 clock base lost CLKG I2MHZ0 clock base lost
26123 3 CLKG I2MHZ1 clock base lost CLKG I2MHZ1 clock base lost
26124 3 CLKG I8KBASE clock base lost CLKG I8KBASE clock base lost
26125 3 CLKG I8KGPS clock base lost CLKG I8KGPS clock base lost
26126 3 CLKG I8KUIM clock base lost CLKG I8KUIM clock base lost
26127 3 Clock base lost third (low) level ala Clock bases set in database have been lost in the
26128 2 Clock base lost second (middle) levClock bases set in database have been lost betw26129 1 Clock base lost first (high) level ala Clock bases set in database have been lost for m
26130 3 Clock base lost Clock base lost
26178 5 CLKG work mode changed CLKG work mode changed
8392704 3 SNTP configuration data error in th Input the wrong configuration data
8392705 3 SNTP client failure in accessing ne There are no any SNTP servers
8393985 2 OSS communication link between 1.The board is not running nomally. 2. The Ctrl_Vl
8393988 2 Communication link broken betwee Communication between MP and OMP error:1.M
8398848 3 SCCP SSN is invalid A subsystem of a remote office found to be out of
8399104 3 SSCS congestion SSCOP detected the buffer useing rate is reach a
8399105 3 SSCS overload SSCOP detected the transmission data buffer is f
8399872 2 MTP2 link transmit traffic overload MTP2 Links transmit traffic load (Erl) exceeds its
8399873 2 MTP2 link receive traffic overload MTP2 Links receive traffic load (Erl) exceeds its r
8400128 2 Office unaccess alarm from MTP3 Office unaccessible
8400129 3 MTP3 link unavailable 1. Link connection broken 2. Link test failure 3. S
8400130 2 Cluster non-access Cluster non access, Not frequently happening
8400131 2 MTP3 link congestion MTP3 link congestion
8400384 2 Office unaccess alarm from M3UA Office unaccessible
8401152 3 SUA SSN is invalid A subsystem of a remote office found to be out of
8401153 2 Office unaccess alarm from SUA Office unaccessible
8402177 3 M2PA link broken 1. Mm2paInitAlignFail 2. Mm2paDataT7Out 3. M
8402688 3 ULP reduce the speed of data SCTP transmit coupling buffer congestion
8402690 2 Association broken down Coupling broken down8402944 2 STC office non-access All couplings are out of service
8417537 3 Associate Path Break AssociatePath Break
1.7E+07 0 Dry contact alarm 1 Major AC Power
1.7E+07 0 Dry contact alarm 2 Critical AC Power
1.7E+07 0 Dry contact alarm 3 Minor high Temperature
1.7E+07 0 Dry contact alarm 4 Critical high Temperature
-
8/10/2019 IOMCR Alarm List-0831
7/130
1.7E+07 0 Dry contact alarm 5 Minor Rectifier
0 Dry contact alarm 6 Critical Minor Rectifier
1.7E+07 0 Dry contact alarm 7 Major Rectifier
1.7E+07 0 Dry contact alarm 8 Critical Major Rectifier
1.7E+07 0 Dry contact alarm 9 Low Voltage
1.7E+07 0 Dry contact alarm 10
1.7E+07 0 Dry contact alarm 11
1.7E+07 0 Dry contact alarm 12
1.7E+07 0 EAM dry contact 1 alarm
1.7E+07 0 EAM dry contact 2 alarm
1.7E+07 0 EAM dry contact 3 alarm
1.7E+07 0 EAM dry contact 4 alarm
1.7E+07 0 EAM dry contact 5 alarm
1.7E+07 0 EAM dry contact 6 alarm
1.7E+07 0 EAM dry contact 7 alarm
1.7E+07 0 EAM dry contact 8 alarm
1.7E+07 3 CMM/CMB FLASH programming faToo many times of FLASH programming, read/
1.7E+07 3 HW link broken BTS internal communication breaks1.7E+07 3 Power overvoltage/undervoltage al CMM/CMB power voltage is out of adjustment
1.7E+07 3 13M input clock failure CMM/CMB clock unit works abnormally
1.7E+07 3 Frame No. inconsistent between so Interference level on the circuit causes frame n
1.7E+07 3 FCLK clock failure CMM/CMB clock unit works abnormally
1.7E+07 3 SYNCLK clock failure CMM/CMB clock unit works abnormally
1.7E+07 4 Master and slave communication li or active-standby CMM/CMB board
1.7E+07 4 Standby CMM/CMB board not pres Standby CMM/CMB board is not inserted
1.7E+07 4 Standby CMM/CMB board abnorm Standby CMM/CMB board starts abnormally or
1.7E+07 3 CMM/CMB power failure alarm CMM/CMB board is power off
1.7E+07 4 Master rack communication link alaCommunication link fault between slave rack a
1.7E+07 4 Communication link alarm between Communication link fault between master rack
1.7E+07 4 Communication link alarm between Communication link fault between master rack
1.7E+07 3 A interface E1 Rx carrier alarm BSC clock, or bad E1 connections, etc
1.7E+07 3 A interface E1 Rx frame not synchr
BSC clock, or bad E1 connections, etc
1.7E+07 3 A interface E1 Tx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 A interface E1 Tx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 A interface E1 Rx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 A interface E1 Rx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 A interface E1 remote alarm Sending line is shorted, the remote end might n
1.7E+07 3 B interface E1 Rx carrier alarm
BSC clock, or bad E1 connections, etc
1.7E+07 3 B interface E1 Rx frame not synchr
BSC clock, or bad E1 connections, etc
1.7E+07 3 B interface E1 Tx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 B interface E1 Tx backward sliding BSC clock, or bad E1 connections, etc1.7E+07 3 B interface E1 Rx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 B interface E1 Rx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 B interface E1 remote alarm Sending line is shorted, the remote end might n
1.7E+07 3 C interface E1 Rx carrier alarm
BSC clock, or bad E1 connections, etc
1.7E+07 3 C interface E1 Rx frame not synchr
BSC clock, or bad E1 connections, etc
1.7E+07 3 C interface E1 Tx forward sliding in
BSC clock, or bad E1 connections, etc
-
8/10/2019 IOMCR Alarm List-0831
8/130
1.7E+07 3 C interface E1 Tx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 C interface E1 Rx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 C interface E1 Rx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 C interface E1 remote alarm Sending line is shorted, the remote end might n
1.7E+07 3 D interface E1 Rx carrier alarm
BSC clock, or bad E1 connections, etc
1.7E+07 3 D interface E1 Rx frame not synchr
BSC clock, or bad E1 connections, etc
1.7E+07 3 D interface E1 Tx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 D interface E1 Tx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 D interface E1 Rx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 D interface E1 Rx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 D interface E1 remote alarm Sending line is shorted, the remote end might n
1.7E+07 3 E interface E1 Rx carrier alarm
BSC clock, or bad E1 connections, etc
1.7E+07 3 E interface E1 Rx frame not synchr
BSC clock, or bad E1 connections, etc
1.7E+07 3 E interface E1 Tx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 E interface E1 Tx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 E interface E1 Rx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 E interface E1 Rx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 E interface E1 remote alarm Sending line is shorted, the remote end might n1.7E+07 3 F interface E1 Rx carrier alarm
BSC clock, or bad E1 connections, etc
1.7E+07 3 F interface E1 Rx frame not synchr
BSC clock, or bad E1 connections, etc
1.7E+07 3 F interface E1 Tx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 F interface E1 Tx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 F interface E1 Rx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 F interface E1 Rx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 F interface E1 remote alarm Sending line is shorted, the remote end might n
1.7E+07 3 G interface E1 Rx carrier alarm
BSC clock, or bad E1 connections, etc
1.7E+07 3 G interface E2 Rx frame not synchr
BSC clock, or bad E1 connections, etc
1.7E+07 3 G interface E1 Tx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 G interface E1 Tx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 G interface E1 Rx forward sliding in BSC clock, or bad E1 connections, etc
1.7E+07 3 G interface E1 Rx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 G interface E1 remote alarm Sending line is shorted, the remote end might n
1.7E+07 3 H interface E1 Rx carrier alarm
BSC clock, or bad E1 connections, etc
1.7E+07 3 H interface E3 Rx frame not synchr
BSC clock, or bad E1 connections, etc
1.7E+07 3 H interface E1 Tx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 H interface E1 Tx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 H interface E1 Rx forward sliding in
BSC clock, or bad E1 connections, etc
1.7E+07 3 H interface E1 Rx backward sliding BSC clock, or bad E1 connections, etc
1.7E+07 3 H interface E1 remote alarm Sending line is shorted, the remote end might n
1.7E+07 4 Temperature alarm Fan fault or module temperature too high
1.7E+07 4 Fan absent Fan not inserted or not in position1.7E+07 4 Fan control board CPU alarmCPU fault
1.7E+07 4 Fan alarm Fan stops rotating due to fault
1.7E+07 4 Fan temperature alarm Fan fault or module temperature too high
1.7E+07 4 Fan 1 alarm Fan stops rotating due to fault
1.7E+07 4 Fan 2 alarm Fan stops rotating due to fault
1.7E+07 4 Fan control board alarm Fan fault or module temperature too high
-
8/10/2019 IOMCR Alarm List-0831
9/130
1.7E+07 3 LNA alarm LNA current exceeds by 30%
1.7E+07 4 Tower amplifier power alarm AEM tower amplifier power alarm
1.7E+07 3 SWR of AEM HYCOM minor Combiner SWR 1.5 alarm
1.7E+07 2 SWR of AEM HYCOM major Combiner SWR 3.0 alarm
1.7E+07 2AEM power alarm(BTS V2) AEM power alarm
1.7E+07 2AEM type alarm(BTS V2) AEM type alarm
1.7E+07 2AEM absent(BTS V2) AEM not-in-position alarm
1.7E+07 2 AEM power alarm AEM power alarm
1.7E+07 3 LNA0 alarm LNA0 current exceeds by 30%
1.7E+07 3 LNA1 alarm LNA1 current exceeds by 30%
1.7E+07 4 Tower Amplifier0 power alarm AEM tower amplifier 0 power alarm
1.7E+07 4 Tower Amplifier1 power alarm AEM tower amplifier 1 power alarm
1.7E+07 3 SWR of AEM HYCOM minor alarm Combiner SWR minor alarm
1.7E+07 2 SWR of AEM HYCOM major alarm Combiner SWR major alarm
1.7E+07 2 AEM type alarm AEM type alarm
1.7E+07 2 AEM Not-in-position alarm AEM not-in-position alarm
1.7E+07 3 CHP DSP0 of TPU initializati DSP software or hardware error
1.7E+07 4 CHP DSP1 of TPU initializati DSP software or hardware error1.7E+07 4 CHP DSP2 of TPU initializati DSP software or hardware error
1.7E+07 4 CHP DSP3 of TPU initializati DSP software or hardware error
1.7E+07 3 Uplink of ADC chip initializati Uplink ADC chip initialization failure
1.7E+07 3 Uplink of ADC resource can't lost suddenly)
1.7E+07 3 CIP resource can't be used Uplink/downlink loop data demodulation failure
1.7E+07 3 Uplink failure Error in uplink data receiving
1.7E+07 3 TPU FLASH Memory failure( read/write error, or software checksum error
1.7E+07 3 Watchdog of TPU CHP DSP DSP0 of channel processing unit has no respo
1.7E+07 4 Watchdog of TPU CHP DSP DSP1 of channel processing unit has no respo
1.7E+07 4 Watchdog of TPU CHP DSP DSP2 of channel processing unit has no respo
1.7E+07 4 Watchdog of TPU CHP DSP DSP3 of channel processing unit has no respo
1.7E+07 3 Watchdog of FUC overflow FUC program has no response temporarily
1.7E+07 4 Wrong Parameter configurati Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong Parameter configurati Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong Parameter configurati Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong Parameter configurati Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong Parameter configurati Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong Parameter configurati Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong Parameter configurati Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong Parameter configurati Parameter configuration error, or conflicts exist
1.7E+07 3 Cell configuration parameter conflicts with channel parameters and CIP
1.7E+07 3 Software version of FUC mis carriers is configured as BCCH, then the
1.7E+07 3 Software version of CHP mis CHP software version load error1.7E+07 4 L3 Software of FUC No Resp MO software (has/has no) response temporaril
1.7E+07 2 LAPD communication link be L2 layer software of FUC does not communicat
1.7E+07 3 Communication link between HDLC link between CMM and TPU breaks, CM
1.7E+07 3 CIP of TPU initialization failurDSP software or hardware error
1.7E+07 3 Wrong Parameter configurati Parameter configuration error, or conflicts exist
1.7E+07 3 Watchdog of TPU CIP overfl DSP program of demodulation module has no r
-
8/10/2019 IOMCR Alarm List-0831
10/130
1.7E+07 3 Software version of CIP mis
carriers is configured as BCCH, then the
1.7E+07 2 Clock alarm for TPU and CM Clock between TPU and CMM is disconnected
1.7E+07 2 TPU power alarm(BTS V2) The power module on TPU board has alarm
1.7E+07 3 TPU frame No. alarm
frame number synchronization source CMM
1.7E+07 3 TPU CHP DSP0 initialization failureDSP software or hardware error
1.7E+07 3 ADC resource unavailable
suddenly, AD6650 initialization failure)
1.7E+07 3 CHP frame error
frame number synchronization source FUC
1.7E+07 3 BURST interrupt error BURST interruption synchronization source
1.7E+07 3 TPU FLASH memory failure
read/write error, or software checksum error
1.7E+07 3 TPU CHP DSP0 watchdog overflo Channel processing unit DSP0 has no respons
1.7E+07 4 Wrong parameter configuration for Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong parameter configuration for Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong parameter configuration for Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong parameter configuration for Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong parameter configuration for Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong parameter configuration for Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong parameter configuration for Parameter configuration error, or conflicts exist
1.7E+07 4 Wrong parameter configuration for Parameter configuration error, or conflicts exist1.7E+07 3 Cell configuration parameter mism
conflicts with channel parameters and CU
1.7E+07 3 FUC Software version mismatch
carriers is configured as BCCH, then the
1.7E+07 3 CHP Software version mismatch CHP software version load error
1.7E+07 3 CU Software version mismatch CU software version load error
1.7E+07 3 HDLC communication link between HDLC link between CMB and TPU breaks, CM
1.7E+07 3 LAPD communication link between communicate with BSC for a certain period
1.7E+07 3 CU intialization failure DSP software or hardware error
1.7E+07 3 CU parameter configuration error Parameter configuration error, or conflicts exist
1.7E+07 4 FUC L3 Software no response MO software (has/has no) response temporaril
1.7E+07 2 TPU power alarm The power module on TPU board has alarm
1.7E+07 3 TPU's FN alarm frame number synchronization source CMB
1.7E+07 3 Rx PLL1 unlock Clock signal is unstable or TRM Phase-Locked
1.7E+07 3 Rx PLL2 unlock Clock signal is unstable or TRM Phase-Locked
1.7E+07 3 Tx PLL1 unlock Clock signal is unstable or TRM Phase-Locked
1.7E+07 3 Tx PLL2 unlock Clock signal is unstable or TRM Phase-Locked
1.7E+07 3 52M referenced clock PLL unClock signal is unstable or TRM Phase-Locked
1.7E+07 3 Tx IF PLL unlock Clock signal is unstable or TRM Phase-Locked
1.7E+07 3 EEPROM resource can't be uEEPROM fault
1.7E+07 3 FPGA interface failure Communication between DSP and FPGA interf
1.7E+07 3 PA VSWR alarm(BTS V2)
Possible reason: open circuit or high
1.7E+07 4 PA overtemperature minor al due to PA working with rated power for a long
1.7E+07 3 PA overtemperature major al due to PA working with rated power for a long
1.7E+07 3 PA output power alarm Direct reason: Difference between PA output p1.7E+07 3 PA power overvoltage PA power overvoltage
1.7E+07 3 PA power lower voltage PA power undervoltage
1.7E+07 3 Downlink checksum error of Interference exists on link between CHP and m
1.7E+07 3 DUC chip initialization failureDUC chip unavailable
1.7E+07 3 80w PA VSWR alarm Direct reason: Reverse power is too high; Poss
1.7E+07 4 80w PA overtemperature
due to PA working with rated power for a long
-
8/10/2019 IOMCR Alarm List-0831
11/130
1.7E+07 3 80w PA overtemperature maj due to PA working with rated power for a long
1.7E+07 3 80w PA output power alarm Direct reason: Difference between PA output p
1.7E+07 3 80w PA power overvoltage PA power overvoltage
1.7E+07 3 80w PA power lower voltage PA power undervoltage
1.7E+07 3 80w PA absent PA not in position
1.7E+07 3 TXIF unlock Clock signal is unstable or DTRM Phase-Locke
1.7E+07 3 TPF unlock Clock signal is unstable or DTRM Phase-Locke
1.7E+07 3 TXRF unlock Clock signal is unstable or DTRM Phase-Locke
1.7E+07 3 RXRF unlock Clock signal is unstable or DTRM Phase-Locke
1.7E+07 3 13 MHz clock lost 13 MHz clock receiving is abnormal, 13 MHz cl
1.7E+07 3 60 ms clock lost
abnormal, 60 ms synchronization clock unit
1.7E+07 3 8M clock of HW lost
MHz clock unit works abnormally
1.7E+07 3 8K clock of HW lost
kHz clock unit works abnormally
1.7E+07 3 52 MHz clock lost
RF board 52 MHz clock unit works abnormally
1.7E+07 3 First ADC clock lost AD6650 clock receiving is abnormal, AD6650 c
1.7E+07 3 Second ADC clock lost AD6650 clock receiving is abnormal, AD6650 c
1.7E+07 3 PA power overvoltage alarm PA power overvoltage
1.7E+07 3 PA power undervoltage alar PA power undervoltage1.7E+07 3 PA VSWR alarm
Possible reason: open circuit or high
1.7E+07 3 PA temperature minor alarm
due to PA working with rated power for a long
1.7E+07 3 PA temperature major alarm
due to PA working with rated power for a long
1.7E+07 3 PA forward power(3db) alarmDirect reason: Difference between PA output p
1.7E+07 2 RTU power alarm RTU power module failure
1.7E+07 3 RTU power temperature alarm RTU power module overheated
1.7E+07 2 RTU power output overvoltage alarm RTU power output overvoltage
1.7E+07 2 RTU power input failure alarm RTU power input failure
1.7E+07 2 IQ calibration parameters ab IQ calibration parameter abnormal
1.7E+07 4 EAM heat exchanger alarm Heat exchanger alarm, reported by dry contact
1.7E+07 4 EAM TRX layer fan-4 alarm CMB0 heater wrong
1.7E+07 4 EAM AEM layer axis-flow fan CMB1 heater wrong
1.7E+07 3 EAM smoke alarm Equipment smoke alarm
1.7E+07 3 EAM waterproof alarm Equipment water alarm
1.7E+07 3 EAM lightning protection alarLightning protector failure alarm
1.7E+07 3 EAM backdoor access controAlarm of back door being opened
1.7E+07 3 EAM frontdoor access controAlarm of front door being opened
1.7E+07 4 EAM PWR monitoring unit al PWR monitoring unit alarm
1.7E+07 3 EAM heat exchanger electric FIB heater alarm
1.7E+07 3 EAM heat exchanger control Heat exchanger control board alarm
1.7E+07 3 EAM heat exchanger externaHeat exchanger external circulation fan 2 alarm
1.7E+07 3 EAM heat exchanger externaHeat exchanger external circulation fan 1 alarm
1.7E+07 2 EAM heat exchanger internal Heat exchanger internal circulation fan 2 alarm1.7E+07 2 EAM heat exchanger internal Heat exchanger internal circulation fan 1 alarm
1.7E+07 3 EAM heat exchanger 485 co Communication break between EAM and heat
1.7E+07 3 EAM temperature alarm Equipment internal environment temperature to
1.7E+07 3 EAM TRX layer mixed-flow faMixed-flow fan 1 damage alarm
1.7E+07 3 EAM TRX layer mixed-flow faMixed-flow fan 2 damage alarm
1.7E+07 3 EAM TRX layer mixed-flow faMixed-flow fan 3 damage alarm
-
8/10/2019 IOMCR Alarm List-0831
12/130
1.7E+07 3 Communication broken betw Communication break between EAM and CMB
1.7E+07 2 Power undervoltage alarm Power voltage is lower than normal
1.7E+07 4 Inner fan 2 alarm (for M8202) Fan stops rotating due to fault
1.7E+07 4 Inner fan 1 alarm (for M8202) Fan stops rotating due to fault
1.7E+07 4 Outer fan 2 and fan 4 alarm (for M8Fan stops rotating due to fault
1.7E+07 4 Outer fan 1 and fan 3 alarm (for M8Fan stops rotating due to fault
1.7E+07 4 Rack temperature minor alarm Fan fault or module temperature too high
1.7E+07 3 Rack temperature major alarm Fan fault or module temperature too high
1.7E+07 4 Layer 3 fan 1 alarm (for M8206) The failure of fans
1.7E+07 4 Layer 3 fan 2 alarm (for M8206) The failure of fans
1.7E+07 4 Layer 3 fan 3 alarm (for M8206) The failure of fans
1.7E+07 4 Layer 2 fan 1 alarm (for M8206) The failure of fans
1.7E+07 4 Layer 2 fan 2 alarm (for M8206) The failure of fans
1.7E+07 4 Layer 2 fan 3 alarm (for M8206) The failure of fans
1.7E+07 4 Layer 1 fan 1 alarm (for M8206) The failure of fans
1.7E+07 4 Layer 1 fan 2 alarm (for M8206) The failure of fans
1.7E+07 4 Layer 1 fan 3 alarm (for M8206) The failure of fans
1.7E+07 2 BSC LAPD communication li BSC LAPD communication link broken1.7E+07 2 Site LAPD communication lin Site LAPD communication link broken
1.7E+07 5 Cell has no traffic Cell has no traffic, cause code: 10
1.7E+07 5 BTS board reset notification 0x151, TRM_CHIP reset; 0x152, AD6650 reset
1.9E+07 2 FR device failure Detected N392 errors in the last N393 STATUS E
1.9E+07 3 FR congestion In case of an intermediate Frame Relay network,
1.9E+07 3 Cell interruption alarm Cell break
1.9E+07 3 Front-end communication lin Front-end communication link broken
1.9E+07 3 MSC overload control alarm at F MSC overload control at FUC mode
1.9E+07 3 CPU overload control alarm at FUCPU overload control at FUC mode
1.9E+07 3 Signaling point congestion control Signal congestion control at FUC mode
1.9E+07 3 MSC overload control alarm at S MSC overload control at SYS mode1.9E+07 3 CPU overload control alarm at S CPU overload control at SYS mode
1.9E+07 3 Signaling point congestion control Signal point congestion control at SYS mode
1.9E+07 3 CCCH overload control Too many users applying for CS service
1.9E+07 3 PCCCH overload control Too many users applying for PS service
1.9E+07 3 NSVC failure alarm Link path failure
1.9E+07 5 NSVC deletion alarm NSVC is deleted
1.9E+07 5 Cell deletion alarm Cell is deleted
1.9E+07 5 Timeout alarm for a databas Timer for waiting DB return expires
1.9E+07 5 NSVC's reception of incorrec NSVC receives incorrect NSVCI
1.9E+07 5 NSVC's reception of incorrec NSVC receives incorrect NSEI
1.9E+07 5 NSVC's reception of NS_ST NSVC receives NS_STATUS_PDU from1.9E+07 5 No access of BSC to MSC S BSC has not configured MSC Office Typ
2625 5 There is a dead lock in process There may be dead lock in some process, for e
2880 5 There Is a Dead Loop There is dead loop in some process or system
3137 5 File operation is fail Notify the OAM agent,when a procedure or task failed t
3392 5 Timer resource is deficient Getting timer control block fails
3648 5 Ub is deficient 1.The configuration number of SBlock is deficient 2.Th
-
8/10/2019 IOMCR Alarm List-0831
13/130
3649 5 Sblock is deficient 1.The configuration number of SBlock is deficient 2.M
3904 5 Communication buffer is full There are too many messages
3905 5 convert function is registered rep Message byte order conversion function regist
5191 5 UIM TFS port state change UIM TFS port state change
5192 5 Board workmode not support 1.Boards workmode is not supported. 2.Board work ab
5648 1 Ctrl Port to UIM Error Ctrl Port to UIM links down or no packets for 35649 2 Port not work on the configed modeReset the workmode of outport , but it fai led for chip pe
5653 2 B Class Error of SETS B Class Error of SETS
5654 1 Powing Error of SETS Powing Error of SETS
5702 5 Work mode difference with DB T Board dont support DB configuration about E1 or T1
5703 5 Backboard switch set change. Backboard switch set change.
5704 5 The work mode of networks chan The work mode of networks change because of itself o
5957 5 Doc space is not enough to save VerF Doc space is not enough to save VerFile
5960 5 Switch version fail Slave board has master process when upgrade EPLD
8001 5 Master to Slave Sync Fai lure There are many reasons for data synchronizing from m
8002 5 OMP to MP Sync Failure OMP requests MP for data synchronizing, MP gives a
8005 5 Dbs FileBuffer Overflow table overflows, there is no enough capacity in filebuffe8008 5 Loading Version Table fail n wher OMP There are new domains or incompatible domain on typ
8009 5 DBS require configuration failed DBS require configuration failed, load data from flash.
11328 5 Failed to config multi-channel conFailed to config multi-channel controller
11329 5 Failed to config Digital Switch chip Failed to config Digital Switch chip
14592 3 dualhome office block dual home office to be slaveprocess dh block office
14593 3 dualhome link block dual home office to be slaveprocess dh block all link
14594 3 dualhome association block dual home office to be slaveprocess dh block all ass
15936 5 2400 Configuration data received from 1.L1InfoAck from DB is NULL. 2.Data in L1InfoAck me
16192 5 Configuration MNIC board received is Configuration is abnormal
16193 5 Sig_ipi transmits packets abnorm Sig_ipi transmits packets abnormally.
16704 5 Configuration MNIC_2 board received i If there is data configuration interface between MCS an17984 5 fail to get route table head or entr IP fail to get route table head or entry
17985 5 fail to del route table head or entr IP opr static rte fail:del srte
17986 5 IP has no match epu globalport IP has no match epu globalport
17987 5 IP create or enable ifb fail IP create or enable ifb fail
17992 5 IP opr static rte fail:add srte IP opr static rte fail:add srte
19008 5 Fail to config the port 1.Fail to config the port of the chip; 2.Fail to config the
19009 5 Fail to create the PVC 1.PVCID is invalid; 2.The ingress connection and the e
19010 5 Fail to delete the PVC Fail to delete the pvc in the chip
19777 5 APS switched reason for switch : los alarm, open enum, clock lose, h
20544 5 Ipoffline inform: invaild interface the interface is not exist or is not a ethernet int
20545 5 Ipoffline inform: use no ip unnumPlease use command: no ip unnumbered first,l20546 5 Ipoffline inform: add address fail add interface address failed
20547 5 Ipoffline inform: set db fail set db failed
20548 5 Ipoffline inform: delete ip address delete the ip address failed
20549 5 Ipoffline inform: invalid address invalid host address
20550 5 Ipoffline inform: invalid next hop invalid nexthop
20553 5 Ipoffline inform: inconsistent in ad inconsistent address and mask
-
8/10/2019 IOMCR Alarm List-0831
14/130
20554 5 Ipoffline inform: add route fail add ip route failed
20555 5 Ipoffline inform: no matched routeno matching route to delete
20556 5 Ipoffline inform: delete route fail delete route failed
20557 5 Ipoffline inform: the next hops co nexthop conflict
20558 5 Ipoffline inform: the next hop no nexthop not directed
20559 5 Ipoffline inform: ip address didnt ip addr not exist20561 5 Ipoffline inform: read DB fail read DB fail
20562 5 Ipoffline inform: no ethernet interf not ethernet interface
20563 5 Ipoffline inform: mac address bey mac beyond valid space
20564 5 Ipoffline inform: DB operated type db mac_oprtype invalid
20565 5 Ipoffline inform: exist ip same pre a same prefix ip address exit
20566 5 Ipoffline inform: invalid broadcase invalid ip broadcast address
20567 5 Ipoffline inform: wrong ip address the number of ip address on this port cannot ex
20568 5 Ipoffline inform: parameter is null the input parameter is null
20569 5 Ipoffline inform: ip already exist The IP address already exists.
20570 5 Ipoffline inform: invalid mask or p IP Offline Cfg: The mask is invalid, or the prefix
21059 5 RIP config neighbor error Addresses are not in the same subnet While a21060 5 RIP interface authentication error authentication testing failed when received a RI
21062 5 RIP neighbor age out RIP neighbor age_out timer expired.
21063 5 RIP interface is disable RIP receive a message that The status of the i
21064 5 RIP interface is enable RIP receive a message that The status of the i
21065 5 RIP version is not compatible ignored packet for Error version when received
21312 5 ospf routerid conflict Router ID in Hello packet matches this router's
21315 5 ospf virtual interface state changeOSPF Virtual link state changed
21316 5 ospf interface state change OSPF interface state changed
21319 5 ospf virtual interface configure erro OSPF virtual link config in error
21320 5 ospf interface configure error OSPF interface config in error
21324 5 ospf virtual interface authentication OSPF virtual link authentication failed21325 5 ospf interface authentication failure OSPF interface authentication failed
21326 5 ospf virtual neighbor state change OSPF virtual link neighbor state changed
21327 5 ospf neighbor state change OSPF neighbor state changed
21328 5 ospf export same lsaid OSPF found LSA with same ls_id
21329 5 ospf lsdb overflow Self-originated or received so many LSA that c
21568 5 Create BGP instance fail BGP failed to allocate memory
21570 5 Create BGP neighbor fail IP Instance is NULL
21572 5 BGP get TCB fail on passive connectio BGP can not get TCB because destination address or
21573 5 BGP get TCB fail on active conneBGP can not get TCB because source addres
21575 5 BGP get TCB fail on enable passiThe number of TCB launched is larger than the
21576 5 INFORM_BGP_ENABLE_ACTIV The number of TCB launched is larger than the21579 5 INFORM_BGP_ADD_PEER_TO_GRO BGP failed to create group/BGP failed to enable group
21580 5 INFORM_BGP_IF_DOWN BGP receive a message that the BGP interface
21581 5 INFORM_BGP_IF_ADDR_CHANBGP interface address is changed
21582 5 INFORM_BGP_READ_BUF_ER BGP reading message, the incorrect buffer len
21584 5 Neighbor hold timer expired BGP neighbor hold timer expired, make the nei
21586 5 Neighbors FSM error BGP neighbors fsm in chaos
-
8/10/2019 IOMCR Alarm List-0831
15/130
21587 5 BGP state changed BGP state change
21826 5 Failed to create OSPF no router ID and can't get one
21831 5 Failed to create OSPF with the given R Cant create timer and table for OSPF
21837 5 Falied to Synchronize route entrieNo memory for new route entry
22336 5 Mac dulicate within bureau Mostly caused by the inconsistent bentween protocol st
22592 5 Create Timer for ISIS failed Timer for ISIS creates fail when initial ISIS22593 5 ISIS Hello packet authenticate failed The authentication mode is not same or the password i
22594 5 ISIS LSP authenticate failed The authentication mode is not same or the password i
22595 5 ISIS SNP authenticate failed The authentication mode is not same or the password i
22596 5 ISIS adjacency state changed The adjancency state changes
22597 5 Receive error ISIS protocol Packet Receive bad ISIS packet
23104 5 The alarm pool of OAM alarmmanage The alarm pool of OAM alarmmanage processis full
23105 5 OAM alarmmanage processreceives in OAM alarmmanage processreceives inform information
23106 5 Board SelfCheck Error OAM alarmmanage processreceives information of boa
23107 5 Board Initialization Error OAM alarmmanage processreceives informatio
25666 5 Inform openning Ec function on non-voiMessage EV_ADDEC received, but the operation shou
26131 3 The pll of CLKG is lost The pll of CLKG is lost26176 5 CLKG base change CLKG base changed
26177 5 CLKG Frequence Base Quality Chang CLKG Frequence Base Quality Changed
26179 5 Base Invalid Reason Changed Base Invalid Reason Changed
28224 5 ospfv3 routerid conflict Router ID in Hello packet matches this router's
28225 5 ospfv3 virtual interface state chang OSPFv3 Virtual link state changed
28226 5 ospfv3 interface state change OSPFv3 interface state changed
28227 5 ospfv3 virtual interface configure erOSPFv3 virtual link config in error
28228 5 ospfv3 interface configure error OSPFv3 interface config in error
28229 5 ospfv3 virtual neighbor state chang OSPFv3 virtual link neighbor state changed
28230 5 ospfv3 neighbor state change OSPFv3 neighbor state changed
28231 5 ospfv3 routerid invalid OSPF3 : Not Config Router ID!28232 5 ospfv3 instance create failure OSPF3 : Create Ospfv3 Instance Failed!
28480 5 The subinterface cannot configure Error because of you configure subinterface to 1200 bo
28736 5 80g chip error 80g test some gliqp has down or 80g chip error
8402945 3 STC office congest Reason 1:only one congestive association can make th
1.9E+07 5 BCCH Exchange Fail BCCH Exchange Fail16784470 2 the alarm of CRC verifying of power a the verifying of power amplifier parameters error
5194 5 CS Fiber Change Over 1. Server Send CMD_FIBER_CHANGEOVER MML C
8012 5 Dbs malloc memory fail Oss malloc memory fail, result in DBS malloc memory f
16640 2 2350 receive hardware error The Alarm happies when MNIC_2 board receive a cert
29505 5 RIPng interface is disable RIPng receive a message that The status of the interfa
29506 5 RIPng interface is enable RIPng receive a message that The status of the interfa
29507 5 RIPng fai led to create rip instance. RIPng fai led to al locate memory
23296 2 The communication flow overd alarmed OAM called the interface of caculating. The flow afford
16784642 2 Control link broken Communication link is broken between HBTS and iBS
16784645 3 Operation link broken(CS) Operation link is broken or no response in specifically ti
16784646 3 Operation link broken(PS) Operation link is broken or no response in specifically ti
16784649 3 Parameter configuration mismatch 1.Parameter configuration mismath from iBSC 2.Overti
16784650 3 DSP initialization failure Softwate or Hardware is failure of DSP
16784651 2 Wrong parameter configuration for Parameter configuration error
16784652 3 Tx PLL unlock Clock signal is unstable or TRM Phase-Locked Loop (
-
8/10/2019 IOMCR Alarm List-0831
16/130
16784654 2 Wrong parameter configuration for statiParameter configuration failure of static link
16784657 3 FLASH memory fault Too many times of FLASH programming, read/write err
16784658 3 DSP watchdog overflow DSP has no response temporarily
16784659 3 FPGA interface fault Communication interface is broken between DSP and
16784665 2 Hardware fault from DSP Hardware error of DSP
16784666 3 CHP frame fault Interrupt fault of frame
16784667 3 CHP frame lost Frame lost of CHP16784668 4 Administrant state cannot be used Parameter configuration error or administrant resource
16784672 4 Wrong parameter configuration for ChaParameter configuration error or conflicts exist for Cha
16784673 4 Wrong parameter configuration for ChaParameter configuration error or conflicts exist for Cha
16784674 4 Wrong parameter configuration for ChaParameter configuration error or conflicts exist for Cha
16784675 4 Wrong parameter configuration for ChaParameter configuration error or conflicts exist for Cha
16784676 4 Wrong parameter configuration for ChaParameter configuration error or conflicts exist for Cha
16784677 4 Wrong parameter configuration for ChaParameter configuration error or conflicts exist for Cha
16784678 4 Wrong parameter configuration for ChaParameter configuration error or conflicts exist for Cha
16784679 4 Wrong parameter configuration for ChaParameter configuration error or conflicts exist for Cha
16784681 2 Resource cannot be used of RF Chann1.Automatic search camer frequency resource failure o
-
8/10/2019 IOMCR Alarm List-0831
17/130
Recommendation for handling with the alarmResponse
time
1. Make sure the fiber is correctly connected; 2. If alarm remaWithin 5 seconds
Check Ethernet physical link Within 5 seconds
Check the remote device for defect Within 5 seconds
Check the remote device for defect Within 5 seconds
Check the remote device for defect Within 5 seconds
Check the remote device for defect Within 5 seconds
Check local and far end device for fault Within 5 seconds
Check local and far end device for fault Within 5 seconds
Unit A transmit CSU Loop Down Code to unit B Within 5 seconds
Check that route clock and receiver clock is equal Within 5 seconds
No such exception happened, so concrete flow cannot be co Within 5 seconds
No such exception happened, so concrete flow cannot be co Within 5 seconds
Check the associated board and the Chip on board Within 5 seconds
Check the associated chip on board Within 5 seconds
Check the CLKG board Within 5 seconds
Check the CLKG board Within 5 secondsCheck the CLKG board Within 5 seconds
Make sure that the 32 MHz clock source and the transmissio Within 5 seconds
Check the CLKG board Within 5 seconds
None Within 5 seconds
None Within 5 seconds
Check the far end transmitter, optical path, and near end receWithin 5 seconds
Eliminate the LOS alarm, check the far end equipment Within 5 seconds
Check the connection of the near end and far end ODF, and t Within 5 seconds
Eliminate the original alarm in the same multiplexing section Within 5 seconds
Eliminate the original alarm in the same multiplexing section Within 5 seconds
Examine the attenuation at various optical connection points Within 5 seconds
Eliminate the SF alarm, check the transmiting side of the AD Within 5 seconds
Check the far end pointer processing unit Within 5 seconds
Check the far end VC-4 path controller Within 5 seconds
Check the connection of the near end and far end ODF, and t Within 5 seconds
Check the path be equipped or not on the far end Within 5 seconds
Check the DXC Within 5 seconds
Eliminate the original alarm in VC-4 path Within 5 seconds
Check the far end VC-4 path controller Within 5 seconds
Check the far end pointer processing unit Within 5 seconds
Check the far end tributary controller Within 5 seconds
Eliminate the original alarm in this tributary Within 5 seconds
Check the far end tributary controller Within 5 secondsCheck the connection of the near end and far end DDF, and tWithin 5 seconds
Check if the path is equipped or not on the far end Within 5 seconds
Check the DXC Within 5 seconds
Examine the attenuation at various optical connection points Within 5 seconds
Examine the attenuation at various optical connection points Within 5 seconds
(1) Find out whether the receive power is too low. If true, mak Within 5 seconds
-
8/10/2019 IOMCR Alarm List-0831
18/130
(1) If there is B1ERR at the same time, handle the B1ERR fir Within 5 seconds
(1) If there is B1ERR or B2ERR at the same time, handle the Within 5 seconds
(1) Check the lower order path transmission quality of the tra Within 5 seconds
(1) Find out whether the receive power is too low. If true, make sure the fiber and
(1) Find out whether the receive power is too low. If true, make sure the fiber and
1Check if the optical fibre is polluted or not; 2Check if the optical power atten1Make SF disappear; 2Let the transmission engineers make sure if the trans
None Within 5 seconds
Reboot board
Check if the cable is linked correctly, if not, link the cable correctly
1.Check whether the cable impedance of our company meets each other,the boar
Check the remote device whether there is e3 subcard corresponding alarm, if it e
Replace the old cable with a new one
Operation depress its flux Within 5 seconds
Check CPU temperature, if it is too high, take appropriate me Within 5 seconds
Increase stack size Within 5 seconds
Reference exception log Within 5 secondsRe-initialize flash device or replace device Within 5 seconds
1. Changeover the board; 2. If the board is OMP, delete useless file; Within 5 seconds
Reboot board Within 5 seconds
Reconnect fibres, or reset DB Within 5 seconds
Check the physical configuration and fiber connections Within 5 seconds
1. If configured in 1+1 backup mode, insert slave board and Within 5 seconds
Check the database configuration to suit the device, if not, co Within 5 seconds
Check trunk connections,correct the wrong ones Within 5 seconds
Check the configuration according to the reference Within 5 seconds
Measure UIM and TFI Within 5 seconds
Check whether the changeover is successful and the changeover re Within 5 seconds
Check the FE port connection Within 5 seconds
Check if all basic processes are correctly registered Within 5 seconds
Check the hardware port and whether the board runs normall Within 5 seconds
Check hardware error, replace the board Within 5 seconds
This Alarm can only be measured on UIM Within 5 seconds
Select other input clock by mml Within 5 seconds
Check 485 physical channel or PWRD switch set Within 5 seconds
Program ensures the consistency of bureau number Within 5 seconds
Program creates the file Within 5 seconds
Program ensures the consistency of OMC MAC Within 5 seconds
Program ensures the consistency of OMC IP Within 5 seconds
Program ensures the consistency of MP type Within 5 secondsProgram creates the file Within 5 seconds
Pull out the alarm (CPU) subcard Within 5 seconds
Insert the (CPU) subcard into the board Within 5 seconds
Program ensures the consistency of OMP Gateway IP Within 5 seconds
Program ensures the consistency of Omc Server IP Within 5 seconds
Program ensures the consistency of OMC Gateway Mask Within 5 seconds
-
8/10/2019 IOMCR Alarm List-0831
19/130
OMP Restart Within 5 seconds
Check the port connection Within 5 seconds
Check the self-board and UIM media VLAN comm Within 5 seconds
1. Check port state information, if port is in normal state, it is Within 5 seconds
Check the 485 hardware and C51 software whether it is normal Within 5 seconds
1.Changeover board and use the IDE of new master board. 2 Within 5 seconds
1Replace the error IDE. 2.Changeover board and use the I Within 5 seconds
Check the trunk line or bcm5615 port Within 5 seconds
Check the board ENUM Within 5 seconds
Pull out and then plug-in the board or use another board Within 5 seconds
Change or pull out and then plug-in the rear board Within 5 seconds
Check the LVDS signal lines on the rear board Within 5 seconds
Check whether the fibers are faulty Within 5 seconds
Reset the board Within 5 seconds
Use the oamback tools to reset the DSP device or the board Within 5 seconds
Contact the related R&D person to find out the reason Within 5 seconds
1.Check if clock reference available. 2Check clock route is Within 5 seconds
Reset the board or use another subcard Within 5 seconds
Check the status of subcard or change it Within 5 seconds
Check the status of Phase Locked Loop Within 5 seconds
Check local device and far end for fault Within 5 seconds
Re-insert the board Within 5 seconds
Re-insert the board Within 5 seconds
1.Check whether the SETS chip is abnormal by the diagnostic test; Within 5 seconds
Reset DSP Within 5 seconds
Reset the DSP or the board. If the warning is still there, the s Within 5 seconds
1. Add the DSP version file; 2. Load version again. Within 5 seconds
Check the status of the board and MCU Within 5 seconds
Change the board Within 5 secondsFormat Flash Within 5 seconds
None Within 5 seconds
Switch to another EPLD version Within 5 seconds
Switch BOOT version again, and reset the board Within 5 seconds
Switch BOOT version again, and reset the board Within 5 seconds
Please refer to the additional information Within 5 seconds
If its "synchronizing file fail", please check if the co Within 5 seconds
Change the chip Within 5 seconds
None Within 5 seconds
Please check the data configuration and retransfer Within 5 seconds
Please check the data configuration and retransfer Within 5 secondsSave all the tables of database on the background system Within 5 seconds
Check the status of the destination board and see iWithin 5 seconds1If the disk is full, please clean up the disk and make sure there i Within 5 seconds
Configure the board again Within 5 seconds
Perform different action according to the cause of Within 5 seconds
To configure and use global title correctly Within 5 seconds
-
8/10/2019 IOMCR Alarm List-0831
20/130
-
8/10/2019 IOMCR Alarm List-0831
21/130
Check the group parameter in the OMC operation request Within 5 seconds
Check the group parameter in the OMC operation request Within 5 seconds
Reboot the board Within 5 seconds
Check PSN board or VSC882 Within 5 seconds
Reboot the board if this error appears continuously Within 5 seconds
Reboot the board if this error appears continuously Within 5 seconds
Reboot the board if this error appears continuously Within 5 seconds
Reboot the board if this error appears continuously Within 5 seconds
Reboot the board if this error appears continuously Within 5 seconds
Reboot the board if this error appears continuously Within 5 seconds
Reboot the board if this error appears continuously Within 5 seconds
Reboot the board if this error appears continuously Within 5 seconds
Reboot the board Within 5 seconds
Reboot the board Within 5 seconds
Check APS configuration and keep local end matched with th Within 5 seconds
Check APS configuration and keep local end matched with th Within 5 seconds
Configure data correctly or use another board Within 5 seconds
Check database configuration Within 5 seconds1. Make sure UIM board is powered-on; 2. Total number of IP Within 5 seconds
1. Confirm that OMP is started up; 2. Check the type of shelf, Within 5 seconds
Reboot Within 5 seconds
Reboot Within 5 seconds
Check if the MP and SCS work normally and the communicaWithin 5 seconds
Check if RPU works normally and its communication is norm Within 5 seconds
Reboot the board Within 5 seconds
View OSS memory configuration Within 5 seconds
View OSS memory configuration Within 5 seconds
Change IP Address Within 5 seconds
Modify the duplicate MAC address Within 5 seconds
Check the memory allocation Within 5 seconds
Check whether the link is normal and the BFD configuration i Within 5 seconds
Check the BFD configuration Within 5 seconds
Use ppdbgenableconncheck enable conncection check at pu Within 5 seconds
Examine the input clock, replace the faulty board Within 5 seconds
Configure correct fixed connection data Within 5 seconds
Reduce the rack temperature Within 5 seconds
Increase the rack temperature Within 5 seconds
Reduce the room temperature Within 5 seconds
Increase the room temperature Within 5 seconds
Regulate and reduce the input voltage Within 5 seconds
Regulate and provide appropriate input voltage Within 5 seconds
Reduce the room humidity Within 5 seconds
Increase the room humidity Within 5 seconds
Check the Fan Within 5 seconds
Check the Door Within 5 seconds
Check the environment Within 5 seconds
Check the environment Within 5 seconds
-
8/10/2019 IOMCR Alarm List-0831
22/130
Check the environment Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 seconds
Check CLKG board and software Within 5 secondsCheck CLKG board and software Within 5 seconds
Check ICM board and software Within 5 seconds
Observe the clock access base on CLKG board Within 5 seconds
Check configuration data in the database Within 5 seconds
Check the SNTP server Within 5 seconds
1.Check whether board run normally 2.Check the communic Within 5 seconds
1.Check whether board run normally 2.Check the communic Within 5 seconds
Restore the faulty subsystem; Bring faulty links back to servicWithin 5 seconds
1.check link status and make it is in congestion by DDM. 2.D Within 5 seconds
Decrease local service flux Within 5 seconds
Reduce the local end's transmit traffic load Within 5 seconds
Reduce the remote end's transmit traffic load Within 5 seconds
Make sure the board's static routing configuration is correct. Within 5 seconds
1.Check the reason of Alarming; 2. Check configuration and Within 5 seconds
Make the cluster accessible Within 5 seconds
Check link Within 5 seconds
Make the office accessible Within 5 seconds
Restore the fault subsystem; Bring fault associations back to Within 5 seconds
Restore the broken associations and make the office accessi Within 5 seconds
Link In Service Within 5 seconds
Reduce uplink data traffic Within 5 seconds
Restore fault associations Within 5 secondsCheck the state of associations Within 5 seconds
Check link and IP configuration Within 5 seconds
Within 5 seconds
Within 5 seconds
Within 5 seconds
Within 5 seconds
-
8/10/2019 IOMCR Alarm List-0831
23/130
Within 5 seconds
Within 5 seconds
Within 5 seconds
Within 5 seconds
Within 5 seconds
Within 5 seconds
Within 5 seconds
Within 5 seconds
Within 10 seconds
Within 10 seconds
Within 10 seconds
Within 10 seconds
Within 10 seconds
Within 10 seconds
Within 10 seconds
Within 10 seconds
The fault arise by FLASH chip failure that user can not solve. Within 10 seconds
1. start HW loop test to distingush the problem of line connec Within 10 seconds
please replace CMM/CMB board as soon as possi Within 10 seconds
clock alarm is shown on front panel . please replace CMM/C Within 10 seconds
if the fault cant restore, clock system of CMM/CMB has probl Within 10 seconds
clock alarm is shown on front panel . please replace CMM/C Within 10 seconds
clock alarm is shown on front panel . please replace CMM/C Within 10 seconds
please replace standby CMM/CMB board as soon as possibl Within 10 seconds
check if standby board is present in the rack. If it is , reset or Within 10 seconds
please replace standby board Within 10 seconds
E1 interface will bridge-connect automatically. Replace the CMM/C Within 10 seconds
1. Check if line between racks is connected. if it has problem Within 10 seconds
1. Check if line between racks is connected. if it has problem Within 10 seconds
1. Check if line between racks is connected. if it has problem Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
-
8/10/2019 IOMCR Alarm List-0831
24/130
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1. Check the electric-connection performance of E1 line. 2. if Within 10 seconds
1.Check the electrical connection properity of the E1 cable.2. Within 10 seconds
check the envirnment temperature.if it conforms to the dema Within 10 seconds
check the fan Within 10 seconds
1. check the line and correct it. 2. check the fan an Within 10 seconds
1. check the line and correct it. 2. check the fan anWithin 10 seconds
Check the environment temperature meets the requirement o Within 10 seconds
Check the alarm circuit have fault or not, if have problem, the Within 10 seconds
Check the alarm circuit have fault or not, if have problem, the Within 10 seconds
Check the environment temperature meets the request or not Within 10 seconds
-
8/10/2019 IOMCR Alarm List-0831
25/130
please replace AEM module as soon as possible. Within 10 seconds
please replace Tower Amplifier module or AEM moWithin 10 seconds
keep on observing.if normal work isnt influenced Within 10 seconds
please replace AEM and reset TRM which conne Within 10 seconds
please replace AEM module as soon as possible. Within 10 seconds
check whether config type of AEM doesnt conform Within 10 seconds
please replace AEM and reset TRM which connect Within 10 seconds
Should replace the AEM module as soon as possible Within 10 seconds
Should replace the AEM module as soon as possible Within 10 seconds
Should replace the AEM module as soon as possible Within 10 seconds
Replace the tower amlifer or AEM module in time Within 10 seconds
Replace the tower amlifer or AEM module in time Within 10 seconds
Continue to observe, if don't affect the normal serverice, then Within 10 seconds
Replace the AEM, or reset the TRM that connected with it Within 10 seconds
Check whether the AEM type that configured match with the Within 10 seconds
Re- download the software of that DSP.2. Reset that DTRM f Within 10 seconds
1.Download software of DSP again. 2.Reset TRM Within 10 seconds
1.Download software of DSP again. 2.Reset TRM Within 10 seconds1.Download software of DSP again. 2.Reset TRM Within 10 seconds
1.Download software of DSP again. 2.Reset TRM Within 10 seconds
1. Reset this module in order to work normally. 2. if Within 10 seconds
1. Reset this module in order to work normally. 2. if Within 10 seconds
if alarm exists, at the same time some traffics exist Within 10 seconds
1.Reset this module in order to work normally. 2. if Within 10 seconds
Reset this CU firstly.If the alarm resumed,it could bWithin 10 seconds
Reset this CU firstly.If the alarm resume,it could be Within 10 seconds
Reset this CU firstly.If the alarm resume,it could be Within 10 seconds
Reset this CU firstly.If the alarm resume,it could be Within 10 seconds
Reset this CU firstly.If the alarm resume,it could be Within 10 seconds
user can reset TPU to solve this problem. If it isnt Within 10 seconds
Wait ten minutes. If the alarm still exists,configure Within 10 seconds
Wait ten minutes. If the alarm still exists,configure Within 10 seconds
Wait ten minutes. If the alarm still exists,configure Within 10 seconds
Wait ten minutes. If the alarm still exists,configure Within 10 seconds
Wait ten minutes. If the alarm still exists,configure Within 10 seconds
Wait ten minutes. If the alarm still exists,configure Within 10 seconds
Wait ten minutes. If the alarm still exists,configure Within 10 seconds
Wait ten minutes. If the alarm still exists,configure Within 10 seconds
Wait ten minutes. If the alarm still exists,configure Within 10 seconds
reset TRM,if it is of no effect, please replace TRM Within 10 seconds
reset TRM,if it is of no effect, please replace TRM Within 10 seconds1.Wait ten minutes and observe whether alarm res Within 10 seconds
1. Check if other FUCs of this base station exist thi Within 10 seconds
system can run, but any data doesnt be configure Within 10 seconds
1. Download DSPs software again. 2.Reset TRM Within 10 seconds
1. Check the parameter of software configuration(FWithin 10 seconds
Reset this CU firstly.If the alarm resume,it could be Within 10 seconds
-
8/10/2019 IOMCR Alarm List-0831
26/130
reset TRM,if it is of no effect, please replace TRM Within 10 seconds
1. If this TPU alarm is the only one alarm in the ba Within 10 seconds
please replace TRM. Within 10 seconds
1.check if FCLK of frame no producing point is nor Within 10 seconds
Re- download the software of that DSP.2. Reset that DTRM f Within 10 seconds
1. Reset that module, make it work normal.2. if it still can't wo Within 10 seconds
1. Measure every Frame clock FCLK that produce frame numWithin 10 seconds
Measure the clock of BURST interruption to check whether it Within 10 seconds
Reset that carrier first, check whether that warning can recov Within 10 seconds
Reset the carrier first, check whether that warning can recoveWithin 10 seconds
If wait for 10 minutes, the warning does not recover, then re-c Within 10 seconds
If wait for 10 minutes, the warning does not recover, then re-c Within 10 seconds
If wait for 10 minutes, the warning does not recover, then re-c Within 10 seconds
If wait for 10 minutes, the warning does not recover, then re-c Within 10 seconds
If wait for 10 minutes, the warning does not recover, then re-c Within 10 seconds
If wait for 10 minutes, the warning does not recover, then re-c Within 10 seconds
If wait for 10 minutes, the warning does not recover, then re-c Within 10 seconds
If wait for 10 minutes, the warning does not recover, then re-c Within 10 seconds
If wait for 10 minutes, the warning does not recover, then re-c Within 10 seconds
Reset the TRM, if it is ineffective, replace the TRM module Within 10 seconds
Reset the TRM, if it is ineffective, replace the TRM module Within 10 seconds
Reset the TRM, if it is ineffective, replace the TRM module Within 10 seconds
The system can continue to work, but any data configuration Within 10 seconds
1. Check whether other FUCs have the warning or not in the Within 10 seconds
check DSP software or hardware Within 10 seconds
1. Check the software parameter( the frequency, thWithin 10 seconds
1.Wait for 10 minuteses observe whether the warning recove Within 10 seconds
Replace the DTRM Within 10 seconds
1. Measure every Frame clock FCLK that produce frame numWithin 10 seconds
1. Check whether clock alarm exists with LMT.if it Within 10 seconds
1. Check whether clock alarm exists with LMT.if it Within 10 seconds
1. Check whether clock alarm exists with LMT.if it Within 10 seconds
1. Check whether clock alarm exists with LMT.if it Within 10 seconds
1. Check whether clock alarm exists with LMT.if it Within 10 seconds
1. Check whether clock alarm exists with LMT.if it Within 10 seconds
please replace TRM module. Within 10 seconds
please replace TRM module. Within 10 seconds
1.Check the connection of PA output with cable. 2.IWithin 10 seconds
Check the fan''s work status and environment tem Within 10 seconds
Check the fan''s work status and environment tem Within 10 seconds
1.Reset TRM and observe. 2. if alarm exists,replac Within 10 secondscheck the check circuit of PA.if it has problem,plea Within 10 seconds
check the check circuit of PA.if it has problem,plea Within 10 seconds
1. Check the signal and time-sequence between C Within 10 seconds
please replace this TRM module. Within 10 seconds
1.Check the connection of PA output with cable. 2 Within 10 seconds
Check the fan''s work status and environment tem Within 10 seconds
-
8/10/2019 IOMCR Alarm List-0831
27/130
Check the fan''s work status and environment tem Within 10 seconds
1.Reset TRM and observe. 2. if alarm exists,replac Within 10 seconds
check the check circuit of PA.if it has problem,pleaWithin 10 seconds
check the check circuit of PA.if it has problem,plea Within 10 seconds
check the check circuit of PA.if it has problem,plea Within 10 seconds
1. See through LMT whether have the clock warning, if have, then r Within 10 seconds
1. See through LMT whether have the clock warning, if have, then r Within 10 seconds
1. See through LMT whether have the clock warning, if have, then r Within 10 seconds
1. See through LMT whether have the clock warning, if have, then r Within 10 seconds
1. Check whether have output or not from 13M clock of TP front pan Within 10 seconds
1. Check whether have output or not from 60ms synchronization clo Within 10 seconds
1. Check whether have output or not from HW's 8M clock of TP fron Within 10 seconds
1.Check whether have output or not from HW's 8K synchronization Within 10 seconds
1. Check whether have output or not from 52M HZ clock of radio fre Within 10 seconds
1. Check whether have output or not from AD6650 clock of TP front Within 10 seconds
1. Check whether have output or not from AD6650 clock of TP front Within 10 seconds
Check whether the PA examination electric circuit break down or notWithin 10 seconds
Check whether the PA examination electric circuit break down or notWithin 10 seconds
1. Check whether the PA output connects the electric cable tightly, i Within 10 seconds
1.Check whether fan works normally or not and whether the environ Within 10 seconds
1.Check whether fan works normally or not and whether the environ Within 10 seconds
1. Reset the DTRM to observe whether warning can recover or not. Within 10 seconds
Replace the RTU circuit board as quickly as possible Within 10 seconds
1.To detect the whether the fans are running and the electric power Within 10 seconds
Replace the RTU circuit board as quickly as possible Within 10 seconds
Replace the RTU circuit board as quickly as possible Within 10 seconds
Replace the RTU circuit board as quickly as possibWithin 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
replace CMB0 heater in time Within 10 seconds
replace CMB1 heater in time Within 10 seconds
Perform on-site check immediately to find fault cause and ha Within 10 seconds
Perform on-site check immediately to find fault cause and ha Within 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
Perform on-site check immediately to find fault cause and cl Within 10 seconds
Perform on-site check immediately to find fault cause and cl Within 10 seconds
Perform on-site check immediately to find fault cause. Within 10 seconds
replace FIB heater in time Within 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
Perform on-site check immediately to find fault cause and ha Within 10 seconds
Perform on-site check immediately to find fault cause and ha Within 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
Perform on-site check immediately to find fault cause and re Within 10 seconds
-
8/10/2019 IOMCR Alarm List-0831
28/130
Perform on-site check immediately to find fault cause and ha Within 10 seconds
Restore external power supply as soon as possible Within 10 seconds
1. Check the alarm connection and eliminate the mWithin 10 seconds
1. Check the alarm connection and eliminate the mWithin 10 seconds
1. Check the alarm connection and eliminate the mWithin 10 seconds
1. Check the alarm connection and eliminate the mWithin 10 seconds
Check the environment temperature, if the temper Within 10 seconds
Check the environment temperature, if the temper Within 10 seconds
1.Examin the error-detection circuit; 2. Examin the fans; 3. Examin t Within 10 seconds
1.Examin the error-detection circuit; 2. Examin the fans; 3. Examin t Within 10 seconds
1.Examin the error-detection circuit; 2. Examin the fans; 3. Examin t Within 10 seconds
1.Examin the error-detection circuit; 2. Examin the fans; 3. Examin t Within 10 seconds
1.Examin the error-detection circuit; 2. Examin the fans; 3. Examin t