INVERTER PT-200 LOCATED IN STBD NOSE COMPARTMENT PROVIDES 36V AC THREE PHASE, 400HZ EQUIPMENT...

6
INVERTER PT-200

Transcript of INVERTER PT-200 LOCATED IN STBD NOSE COMPARTMENT PROVIDES 36V AC THREE PHASE, 400HZ EQUIPMENT...

INVERTER PT-200

LOCATED IN STBD NOSE COMPARTMENTPROVIDES 36V AC THREE PHASE, 400HZ

EQUIPMENT FAILURES DUE TO • FAN COVER DAMAGE• FAILURE OF BEARING• MALFUNCTIONING OF CENTRIFUGAL S/W• RESISTORS OUT OF ADJUSTMENT

FAILURE WILL CAUSE DE-ENERGISING OF 36V EMERGENCY BUS BAR

INVERTER PT-200 SERIES 4LOCATION

INPUT VOLTAGE – 27V DC±2.7VINPUT CURRENT – 14.0 AMPSOUTPUT VOLTAGE – 35.5 TO 40.0V ACTHREE PHASE, SINE WAVEAC LOAD CURRENT – 3.2 AMPSOUTPUT FREQUENCY – 400 HZ±2%OUTPUT POWER – 200VAEFFICIENCY – 31.7% MINIMUMPOWER FACTOR – 0.6 (INDUCTIVE)OPERATING TEMPERATURE - ±60°CALTITUDE FOR CONTINUOUS OPERATION UPTO 15,000 M - RATED LOAD

18000 M - 75% LOADWEIGHT – 08.6 KGADDITIONAL REQUIREMENTS – REMOTE ON/OFF AND OVERLOAD PROTECTION

TECCHNICAL

SPECIFICATIONS

EQUIPMENT ELECTRO-MECHANICAL AND ROTARY IN NATURE REQUIRED TO BE REPLACED WITH SOLID STATE STATIC VERSIONDESIGN CLEARANCE FROM CEMILAC

THE REQUIREMENT FOR FIVE YEARS IS 250

BACK TO LIST