28
Multi Series Inverter Multi-Split System Air Conditioners MHIAA is proudly sponsoring Monika’s Doggie Rescue

Transcript of Inverter Multi-Split System Air Conditioners MHIAA is proudly sponsoring … · 2015. 8. 21. ·...

  • Multi SeriesInverter Multi-Split System Air Conditioners MHIAA is proudly sponsoring Monika’s Doggie Rescue

  • MULTI series Air Conditioners 2013

    2 Multi SeriesInverter Multi-Split System Air Conditioners.

    The ideal solution for air conditioning multiple rooms

  • A home typically has many areas such as bedrooms, living spaces and study rooms. Therefore, to provide total comfort for your home, a multi-split system is recommended so each room can have its own air conditioner.

    This can be achieved through a Mitsubishi Heavy Industries inverter multi-split system which delivers optimum heating or cooling for everyone, no matter where they are in the home and no matter what size the room may be. Silent, powerful, energy ef� cient and utilising advanced technologies, a Mitsubishi Heavy Industries inverter multi-split system is the solution for homes with many rooms and occupants.

    3

    WE

    LCO

    ME

  • MULTI series Air Conditioners 2013

    4

    CompactA Mitsubishi Heavy Industries inverter multi-split system allows 2 to 6 indoor units to be connected to a single outdoor unit. This allows multiple rooms to be conditioned without adding clutter to the exterior of your home. One compact multi-split outdoor unit instead of many outdoor units not only adds to the ascetic appeal your home but can be imperative when there is not much space available, for example, when installing outdoor units on balconies or verandahs.

    Installation FlexibilityWith a generous maximum piping length of 70m*, you are given greater freedom to decide where the indoor units will be installed to optimise interior space and convenience. In addition, a maximum height difference of 25m* for the indoor units means the Mitsubishi Heavy Industries inverter multi-split system can easily service the rooms for multi storey homes.

    Variety of Indoor UnitsThe indoor unit range includes wall mounted, fl oor standing, low static bulkhead or compact cassette types in a wide range of capacities. This makes hundreds of combinations possible for your home. You can choose the right type of indoor unit to complement the interior décor and match the size of each room.

    *Please check model specifi cations as these pipe lengths and height differences do not apply to all models.

  • 5

    MU

    LTI C

    ON

    CE

    PT

    Independent Control and ComfortEach indoor unit comes with its own remote allowing the unit to be independently switched on/off and have the temperature adjusted as needed. The conditions of rooms can vary greatly depending on many variables such as the number of occupants or the way the room is used. With a range of comfort, air fl ow and convenience functions on each indoor unit, you can adjust the settings to match the requirements of a room without affecting other ones. When a room is unoccupied you can switch off the unit to reduce ineffi cient energy use.

    5 Year WarrantyWhen you buy a Mitsubishi Heavy Industries inverter multi-split system, you are getting an air conditioning solution from a company that some of the highest quality products in the industry. Mitsubishi Heavy Industries enjoys a reputation for outstanding quality and is highly respected both in the Australian and overseas markets. With our 5 Year Warranty covering the parts, labour and compressor, you can peace of mind that your new Mitsubishi Heavy Industries inverter multi-split system will continue to deliver air-conditioning comfort to your home through the years.

  • MULTI series Air Conditioners 2013

    66

    Easy operationAll settings done by tapping touch screen panel

    Operation mode

    Cooling Dry Auto HeatingFan

    Operation mode setting screen

    The operation mode canbe selected by simply tappingthis button.

    Setting temperature screen

    You can select the desired temperature by tapping the ▲▼ button.

    Main functions

    Energy managementPeak cut timer • Automatic temperature set back • Weekly timer • Set ON/OFF timer by hour • Set ON/OFF timer by clock • Fan only operation • Sleep timer

    ComfortIndividual fl ap control • High power operation • External ventilation ON/OFF • Warm up operation • Automatic fan speed • Temperature increment setting by 0.5ºC

    ConvenienceLCD contrast setting • Back light setting • Filter clean sign • Control sound • Outdoor silent mode • Summer time setting • Home leave mode • Indoor & outdoor temperature display • Heating standby display • Defrosting operation display • Auto cooling/heating display • ºC/ºF display • Administrator settings • Room name setting

    ServiceError code display • Operation data display • Next service data display • Contact company display • USB connection (mini-B)

  • 7

    CO

    NT

    RO

    L & F

    UN

    CT

    ION

    S

    Comfortable Functions

    Automatic OperationThe air conditioner automatically selects from heating, cooling or dry operation.

    "HI POWER" OperationThe unit can operate continuously in HI POWER mode for 15 minutes. This mode is used to reach the desired temperature quickly.

    Three "Hot" System‘Hot start’ enables the unit to begin heating operation quickly.‘Hot spurt’ is a fast heating system that works to increase the temperature setting by two degrees.‘Hot keep’ is used during the automatic defrost cycle to prevent cool air being circulated.These three operational control systems help ensure comfortable and efficient heating.

    3HOT

    St

    art

    Keep

    Spurt

    On TimerThis enables the operation to start a little earlier so that the room is near to the set temperature at ON time.

    On Timer

    Microcomputer-Operated DefrostingThis function automatically eliminates frost and helps minimize excessive operation in other modes.

    MC

    When removing the air inlet panel for internal cleaning or other reasons, open the grill by 65 degrees and then pull it to the side.

    Detachable Indoor Air Inlet PanelThe air inlet panel on the indoor unit opens and closes easily making filter cleaning simple. The suction panel can be easily removed.

    Detachable

    Self-Diagnostic FunctionIf the air conditioner malfunctions an internal microcomputer runs a self diagnosis. Inspection and repair should be performed by authorized dealers.

    DiagnosticSelf

    Power blackout auto restart function records the operational status of the air conditioner immediately prior to being switched off by a power supply interruption. The unit automatically resumes operations in the mode and temperature set point after the power has been restored.

    Auto Restart FunctionRestart

    Auto

    On the indoor unit there is a back up on/off switch. The system will operate in the previous mode.

    Back-up SwitchBack-upSwitch

    Others

    Economy ModeEconomyThe unit achieves effective energy saving operation while still keeping a comfortable cooling or heating operation.

    Dry OperationDRY The unit dehumidifies the room by intermittent cooling operation.

    24-hour On/Off Programmable TimerBy combining a start timer with a stop timer you can register two timer operations a day. Once set timers will start or stop the system at the specified time of the day repeatedly.

    24h Timer

    Off TimerOFF TimerThe unit stops at the specified time.

    Sleep ModeSleepThe room temperature is automatically controlled during the set sleep mode period ensuring that the room temperature will not get too hot or cold.

    Convenience & Economy Functions

    Maintenance & Prevention Functions

    Comfortable Air Flow Functions

    Slant forwardblowing

    HEATING

    Auto Flap ModeThe unit automatically selects the optimal angle whatever the operation mode.

    Auto Flap Horizontal blowingCOOLING & DRY

    Fuzzy Auto ModeAutomatically the unit determines its operating mode and temperature setting based on a fuzzy calculation and adjusts the inverter frequency.

    You can choose the best heating or cooling pattern with the touch of a button.

    3D Auto

    Auto

    Thick line : moves quicklyThin line : moves slowly

    COOLING & DRY

    HEATINGThick line : moves quicklyThin line : moves slowly

    Air ScrollThe swing of the flap causes the air flow to spiral and the breeze to reach all corners of the room.

    Air Scroll

    Filter

    Photocatalytic Washable Deodorizing FilterIt keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be easily restored simply by cleaning and exposing the �lter to the sunlight.

    Allergen Clear FilterThe �lter breaks down the pollen, lice, and all allergens that live on cat skins, etc. and deactivates them.

    SUNFilterSUNFilterSUNFilter

    AllergenFilterAllergenFilterAllergenFilter

    SWING FLAPFlap moves up and down continuously.

    Memory FlapWhile the flap is swinging it can be stopped at any angle. The flap returns to this position next time the unit starts.

    Memory

    Up/Down Flap SwingThe Up/Down flap can be adjusted to the preferred angle anywhere between horizontal and perpendicular.

    UP/DOWN

    Lateral SwingThe louver swings from right to left automatically. Louver angle can be fixed in any desired position.

    Lateral

    Swing

    You can set the left-right air �ow directions when you install the air conditioner near the side wall by remote controller operation.

    Positioning of

    installation

    Positioning of Installation

    Both lower and upper air outlets and upper air outlet can be selected. (SRF models only)

    Air outletselection

    Air Outlet Selection

    With wireless “Luminous” remote controls that even “glow in the dark”, it is possible to operate all desired functions of the unit with the click of a button.

    Luminous

    24-hour IONThe air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.

    24h ION

    Luminous Button

    Natural Enzyme FilterEnzymes used in the �lter are naturally occurring lytic enzymes which attack cell walls of microorganisms trapped on the �lter and destroy them.

    See details on page 2.

    EnzymeFilter

    EnzymeFilter

    EnzymeFilter

    Self CleanOperationSelf CleanOperationSelf CleanOperation

    AllergenSystemAllergenSystemAllergenSystem

    Functions.

  • MULTI series Air Conditioners 2013

    8

    Advanced Technology.

    DC PAM inverterAn inverter system has a number of advantages over a constant speed system. Its variable speed compressor outputs can ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner can slow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motor driven so it provides superior performance.

    High Ef� ciency.

    CONVENTIONALINVERTER

    CONVENTIONAL

    Time

    Room Temp.

    ON

    Less advanced technology does not addressthe ON/OFF cycle issue.

    OFFRated Capacity

    OFF

    Set Temp.

    Compressor(rps)

    DC PAMINVERTER

    DC PAMINVERTER

    Time

    Room Temp.

    Even Temperature

    ONRated Capacity

    Utmost comfort and energy efficiency achievedwith large output power and control optimisation

    Set Temp.

    Compressor(rps)

    PWMPAM

    DC compressor motor

    Mot

    or E

    ffic

    ienc

    y(%

    )

    Magnet Motor

    Induction Motor

    Low High

    Improving

    Improving

    Revolution speedINVERTER

    DCPAM

    PowerActiveModule

    New inverter control (Vector control)New Inverter Control has applied the new advanced technology of Vector control enabling:- • Smooth operation from low to high speed• Smooth Sine Voltage Wave form is achieved • Energy effi ciency has improved in low speed range

    Propeller fanThe new propeller fan was carefully matched with a fan motor in order to keep the same capacity as that of previous models with less electrical consumption.

    Superior corrosion resistanceThe base of the outdoor unit is hot dipped to provide superior corrosion and scratch resistance.

    Outdoor unitRedesigned by changing the � n con� guration from � at sheet to new M shape � n, ef� ciency has been improved. An optimum balance of heat transfer and air � ow has been achieved.

    Silicon-coated PCBThe printed circuit board of the outdoor unit is coated by silicon. The coating ensures longevity of the board in humid conditions.

  • 9

    FE

    ATU

    RE

    SAdvanced Technology.

    All SRK, SRF

    Applied models

    SRK50/60ZJX, SRK-ZKSRF-50ZJX

    Applied models

    60dB 50dB 40dB 30dB 21dB

    SRK20ZJX-S(In the Cooling Lo mode)

    70dB

    60dB

    50dB

    40dB

    30dB

    20dB

    10dB

    0dB

    Comparison with fam

    iliar noises in our eve

    ryday life

    Normal conversation

    s

    Quiet of�ce

    In the library Late night

    in a

    typical suburban ar

    ea

    21dB

    20m

    30mMaximum height difference

    Maximum pipe length

    For the capacities under low temperature conditions, refer to technical manual.

    50403020100-10-20

    Heating

    Cooling +46°C

    +21°C

    -15°C

    -15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

    Applied models

    All SRK, SRF, SRR, FDTC

    SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

    All SCM-appearance may varyAll SRK, SRFApplied models

    SRK50/60ZJX, SRK-ZKSRF-50ZJX

    Applied models

    60dB 50dB 40dB 30dB 21dB

    SRK20ZJX-S(In the Cooling Lo mode)

    70dB

    60dB

    50dB

    40dB

    30dB

    20dB

    10dB

    0dB

    Comparison with fam

    iliar noises in our eve

    ryday life

    Normal conversation

    s

    Quiet of�ce

    In the library Late night

    in a

    typical suburban ar

    ea

    21dB

    20m

    30mMaximum height difference

    Maximum pipe length

    For the capacities under low temperature conditions, refer to technical manual.

    50403020100-10-20

    Heating

    Cooling +46°C

    +21°C

    -15°C

    -15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

    Applied models

    All SRK, SRF, SRR, FDTC

    SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

    All SCM-appearance may vary

    All SRK, SRF

    Applied models

    SRK50/60ZJX, SRK-ZKSRF-50ZJX

    Applied models

    60dB 50dB 40dB 30dB 21dB

    SRK20ZJX-S(In the Cooling Lo mode)

    70dB

    60dB

    50dB

    40dB

    30dB

    20dB

    10dB

    0dB

    Comparison with fam

    iliar noises in our eve

    ryday life

    Normal conversation

    s

    Quiet of�ce

    In the library Late night

    in a

    typical suburban ar

    ea

    21dB

    20m

    30mMaximum height difference

    Maximum pipe length

    For the capacities under low temperature conditions, refer to technical manual.

    50403020100-10-20

    Heating

    Cooling +46°C

    +21°C

    -15°C

    -15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

    Applied models

    All SRK, SRF, SRR, FDTC

    SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

    All SCM-appearance may vary

    All SRK, SRF

    Applied models

    SRK50/60ZJX, SRK-ZKSRF-50ZJX

    Applied models

    60dB 50dB 40dB 30dB 21dB

    SRK20ZJX-S(In the Cooling Lo mode)

    70dB

    60dB

    50dB

    40dB

    30dB

    20dB

    10dB

    0dB

    Comparison with fam

    iliar noises in our eve

    ryday life

    Normal conversation

    s

    Quiet of�ce

    In the library Late night

    in a

    typical suburban ar

    ea

    21dB

    20m

    30mMaximum height difference

    Maximum pipe length

    For the capacities under low temperature conditions, refer to technical manual.

    50403020100-10-20

    Heating

    Cooling +46°C

    +21°C

    -15°C

    -15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

    Applied models

    All SRK, SRF, SRR, FDTC

    SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

    All SCM-appearance may vary

    All SRK, SRF

    Applied models

    SRK50/60ZJX, SRK-ZKSRF-50ZJX

    Applied models

    60dB 50dB 40dB 30dB 21dB

    SRK20ZJX-S(In the Cooling Lo mode)

    70dB

    60dB

    50dB

    40dB

    30dB

    20dB

    10dB

    0dB

    Comparison with fam

    iliar noises in our eve

    ryday life

    Normal conversation

    s

    Quiet of�ce

    In the library Late night

    in a

    typical suburban ar

    ea

    21dB

    20m

    30mMaximum height difference

    Maximum pipe length

    For the capacities under low temperature conditions, refer to technical manual.

    50403020100-10-20

    Heating

    Cooling +46°C

    +21°C

    -15°C

    -15°CSRK-ZJX, SRK-ZK, SRK-ZJ, SRF-ZJX

    Applied models

    All SRK, SRF, SRR, FDTC

    SRK50/60ZJX, SRK-ZK, SRK35/50ZJ, SRK-ZJX

    All SCM-appearance may vary

    Live Bacteria Count on Measured Test Pieces

    Test Pieces 1) Products with Antimicrobial and Antifungal Treatment

    TestedContaminant Measurement Test Pieces

    Bacteria Count Per Test PieceMeasurement 1 Measurement 2 Measurement 3

    Escherichia coli IFO 3972 coli

    Aspergillusniger

    Staphylococcusaureus

    Immediately after contact

    After 24 hrs at 35°C

    Not treated 1.9 x 105

  • MULTI series Air Conditioners 2013

    10 3D AUTO Vertical + Horizontal AIR SCROLL.

    SRK-ZJX, SRK-ZJ

    SRK63/71/80ZK, Manual Setting only

    Applied models

    3D AUTO

    Swing

    Vertical Swing

    Horizontal Air Scroll 8 Direction Swing

    1 2 3 4

    8 7 6 5

    Swing Spot Wide

    3

    4

    2

    1

    Cool Shower

    Cool Shower

    Floor Heating

    Floor

    Swing

    Swing

    Swing

    Hi-Power (Quick)

    Wide Swing (Every Corner)

    Center (Long)

    Wide-Air (Equal)

    3 motors make 3 independent controls3 motors make 3 independent controls

    Programmed air distribution

    SRK-ZJX, SRK-ZJ

    SRK63/71/80ZK, Manual Setting only

    Applied models

    3D AUTO

    Swing

    Vertical Swing

    Horizontal Air Scroll 8 Direction Swing

    1 2 3 4

    8 7 6 5

    Swing Spot Wide

    3

    4

    2

    1

    Cool Shower

    Cool Shower

    Floor Heating

    Floor

    Swing

    Swing

    Swing

    Hi-Power (Quick)

    Wide Swing (Every Corner)

    Center (Long)

    Wide-Air (Equal)

    3 motors make 3 independent controls3 motors make 3 independent controls

    Programmed air distribution

    SRK-ZJX, SRK-ZJ

    SRK63/71/80ZK, Manual Setting only

    Applied models

    3D AUTO

    Swing

    Vertical Swing

    Horizontal Air Scroll 8 Direction Swing

    1 2 3 4

    8 7 6 5

    Swing Spot Wide

    3

    4

    2

    1

    Cool Shower

    Cool Shower

    Floor Heating

    Floor

    Swing

    Swing

    Swing

    Hi-Power (Quick)

    Wide Swing (Every Corner)

    Center (Long)

    Wide-Air (Equal)

    3 motors make 3 independent controls3 motors make 3 independent controls

    Programmed air distribution

    SRK-ZJX, SRK-ZJ

    SRK63/71/80ZK, Manual Setting only

    Applied models

    3D AUTO

    Swing

    Vertical Swing

    Horizontal Air Scroll 8 Direction Swing

    1 2 3 4

    8 7 6 5

    Swing Spot Wide

    3

    4

    2

    1

    Cool Shower

    Cool Shower

    Floor Heating

    Floor

    Swing

    Swing

    Swing

    Hi-Power (Quick)

    Wide Swing (Every Corner)

    Center (Long)

    Wide-Air (Equal)

    3 motors make 3 independent controls3 motors make 3 independent controls

    Programmed air distribution

    3D AUTO is a one touch programme. Three motors (one vertical working motor + two horizontal working motors) make three independent air � ow controls.The air� ow is uniform, quiet and reaches at long distance from the indoor unit.

    Programmed 3D AUTOAutomatic control of air � ow volume and air � ow direction enables comfortable air conditioning of the entire room. In cooling operation, cooled air � ows directly to the ceiling not directly onto the occupants of the room. The comfort cooled air � ow comes down from the ceiling like a soft shower.In heating operation, warm air � ows to the � oor directly and spreads along the � oor. The concentration of the warm air at � oor level increases comfort.

    Manual SettingIndividual control of right and left louver enables air � ow direction from the right and the left side of the unit, setting the most preferable air � ow direction and determining whether direct air � ow is required or not.

  • 11

    FE

    ATU

    RE

    SJet air scroll long reach & silent air � ow.

    We used the same aerodynamic analysis technology as used in developing jet engines.CFD (computational � uid dynamics) is used for blade shape design and air channels for jet engines. The same technology has been used in our air conditioners. The air� ow of the jets created in this system enables a large volume of air to be blown with a minimum amount of power consumption. The air� ow is uniform, quiet and reaches a long distance from the indoor unit.

    New louver The new louver has a new design and shape.It has increased in surface area by 80%. In addition to improved control of the increased air � ow volume, it has improved controllability of the right to left swing function.

    Fast SlowColors in the �gure show the air speed.

    Aircraft technology was used in the design of the air conditioner’s airflow system

    SRK71ZK(in cooling operation)

    17m15m

    SRK50/60ZJX(in cooling operation)

    powerful

    Newprevious

    80% increased

    Newprevious

    80% increased

    Positioning of InstallationYou can set the left-right air � ow directions when you install the air conditioner near the side wall by remote controller operation.

    Long Reach Air FlowThe jet technology enables powerful air� ow ideal for large living areas and commercial premises, increasing your comfort.

  • MULTI series Air Conditioners 2013

    12 Clean Air.

    Catching Allergen on the Filter

    AIR Purify

    Cooling OperationTo make condensing water.

    Heating OperationTo give moisture to the Filter to inactivate allergen

    Self-Clean OperationTo dry up the indoor unit

    Self Clean OperationThe ‘self clean operation’ is operated for 2 hours after the unit has ceased normal operation. The indoor fan continues to operate on ultra low speed to dry the unit. This restricts the growth of mould. This feature can be selected on the remote control.

    Allergen Clear SystemThe ‘Allergen Clear system’ suppresses the in� uence of the allergen caught by the � lter by controlling the temperature and humidity.

    Generates the same amount of negative ions as a forest environment

    24-hour IONThe air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are generated even when the air conditioner is not running, allowing you to experience them without incurring any electrical cost.

    The air in your room is kept fresh

    Allergen clear systemThe ‘Allergen Clear system’ suppresses the in� uence of the allergen caught by the � lter by controlling the temperature and humidity.

    After one weekwithout self clean opration

    After one weekwith self clean opration

    First in the world20 of Patent Pending

    Stop run 2hrs

    Normaloperation

    Cleanoperation

    Shuts off automatically

    Situation of mold after one week

    Situation of mold after one week

    Fungal mycelia expand.

    The spore of mold doesn't germinate.

    When you execute “Self Clean Operation”When you don’t execute “Self Clean Operation”

    Fungal mycelia

    Spore of mold

    Spore of mold

    Stop run 2hrs

    Normaloperation

    Cleanoperation

    Shuts off automatically

    Situation of mold after one week

    Situation of mold after one week

    Fungal mycelia expand.

    The spore of mold doesn't germinate.

    When you execute “Self Clean Operation”When you don’t execute “Self Clean Operation”

    Fungal mycelia

    Spore of mold

    Spore of mold

    Stop run 2hrs

    Normaloperation

    Cleanoperation

    Shuts off automatically

    Situation of mold after one week

    Situation of mold after one week

    Fungal mycelia expand.

    The spore of mold doesn't germinate.

    When you execute “Self Clean Operation”When you don’t execute “Self Clean Operation”

    Fungal mycelia

    Spore of mold

    Spore of mold

  • 13

    FE

    ATU

    RE

    S

    CouplingCell wall

    Filter �ber

    Enzyme EnzymeBacterium

    Powerful sterilizing effect

    Enzyme's sterilizing mechanism

    Sterilization Mechanism

    -COOH

    H2N-

    Protein structure of allergen

    Urea Enzyme

    A molecule is decomposed

    Slack of high order structure Reduction in a molecule

    Inac

    tivat

    ion

    rate

    (%)

    100

    50

    0

    83.5%93.6%

    72.7%83.5%

    99.9% 99.0%

    Rate of inactivation against allergens collected on the �lter

    House dust mite*1 *1 *2 *2 *3 *3

    A species of mite Cedar pollen Epithelium of cat Virus i Virus p

    Photocatalytic Washable Deodorizing Filter

    Allergen Clear Filter

    Filter Indoor Unit

    Used in models

    *1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

    Air

    �o

    w

    Conventional Filter Enzyme Filter

    Analysis ZoneAnalysis Zone

    Natural Enzyme Filter

    SRF-ZJXSRK-ZKSRK-ZJX

    1pc

    -

    1pc

    SRK-ZJ

    1pc

    -

    1pc

    -

    1pc

    1pc

    1pc

    -

    1pc

    First in the world

    CouplingCell wall

    Filter �ber

    Enzyme EnzymeBacterium

    Powerful sterilizing effect

    Enzyme's sterilizing mechanism

    Sterilization Mechanism

    -COOH

    H2N-

    Protein structure of allergen

    Urea Enzyme

    A molecule is decomposed

    Slack of high order structure Reduction in a molecule

    Inac

    tivat

    ion

    rate

    (%)

    100

    50

    0

    83.5%93.6%

    72.7%83.5%

    99.9% 99.0%

    Rate of inactivation against allergens collected on the �lter

    House dust mite*1 *1 *2 *2 *3 *3

    A species of mite Cedar pollen Epithelium of cat Virus i Virus p

    Photocatalytic Washable Deodorizing Filter

    Allergen Clear Filter

    Filter Indoor Unit

    Used in models

    *1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

    Air

    �o

    w

    Conventional Filter Enzyme Filter

    Analysis ZoneAnalysis Zone

    Natural Enzyme Filter

    SRF-ZJXSRK-ZKSRK-ZJX

    1pc

    -

    1pc

    SRK-ZJ

    1pc

    -

    1pc

    -

    1pc

    1pc

    1pc

    -

    1pc

    First in the world

    CouplingCell wall

    Filter �ber

    Enzyme EnzymeBacterium

    Powerful sterilizing effect

    Enzyme's sterilizing mechanism

    Sterilization Mechanism

    -COOH

    H2N-

    Protein structure of allergen

    Urea Enzyme

    A molecule is decomposed

    Slack of high order structure Reduction in a molecule

    Inac

    tivat

    ion

    rate

    (%)

    100

    50

    0

    83.5%93.6%

    72.7%83.5%

    99.9% 99.0%

    Rate of inactivation against allergens collected on the �lter

    House dust mite*1 *1 *2 *2 *3 *3

    A species of mite Cedar pollen Epithelium of cat Virus i Virus p

    Photocatalytic Washable Deodorizing Filter

    Allergen Clear Filter

    Filter Indoor Unit

    Used in models

    *1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

    Air

    �o

    w

    Conventional Filter Enzyme Filter

    Analysis ZoneAnalysis Zone

    Natural Enzyme Filter

    SRF-ZJXSRK-ZKSRK-ZJX

    1pc

    -

    1pc

    SRK-ZJ

    1pc

    -

    1pc

    -

    1pc

    1pc

    1pc

    -

    1pc

    First in the world

    CouplingCell wall

    Filter �ber

    Enzyme EnzymeBacterium

    Powerful sterilizing effect

    Enzyme's sterilizing mechanism

    Sterilization Mechanism

    -COOH

    H2N-

    Protein structure of allergen

    Urea Enzyme

    A molecule is decomposed

    Slack of high order structure Reduction in a molecule

    Inac

    tivat

    ion

    rate

    (%)

    100

    50

    0

    83.5%93.6%

    72.7%83.5%

    99.9% 99.0%

    Rate of inactivation against allergens collected on the �lter

    House dust mite*1 *1 *2 *2 *3 *3

    A species of mite Cedar pollen Epithelium of cat Virus i Virus p

    Photocatalytic Washable Deodorizing Filter

    Allergen Clear Filter

    Filter Indoor Unit

    Used in models

    *1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

    Air

    �o

    w

    Conventional Filter Enzyme Filter

    Analysis ZoneAnalysis Zone

    Natural Enzyme Filter

    SRF-ZJXSRK-ZKSRK-ZJX

    1pc

    -

    1pc

    SRK-ZJ

    1pc

    -

    1pc

    -

    1pc

    1pc

    1pc

    -

    1pc

    First in the world

    CouplingCell wall

    Filter �ber

    Enzyme EnzymeBacterium

    Powerful sterilizing effect

    Enzyme's sterilizing mechanism

    Sterilization Mechanism

    -COOH

    H2N-

    Protein structure of allergen

    Urea Enzyme

    A molecule is decomposed

    Slack of high order structure Reduction in a molecule

    Inac

    tivat

    ion

    rate

    (%)

    100

    50

    0

    83.5%93.6%

    72.7%83.5%

    99.9% 99.0%

    Rate of inactivation against allergens collected on the �lter

    House dust mite*1 *1 *2 *2 *3 *3

    A species of mite Cedar pollen Epithelium of cat Virus i Virus p

    Photocatalytic Washable Deodorizing Filter

    Allergen Clear Filter

    Filter Indoor Unit

    Used in models

    *1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

    Air

    �o

    w

    Conventional Filter Enzyme Filter

    Analysis ZoneAnalysis Zone

    Natural Enzyme Filter

    SRF-ZJXSRK-ZKSRK-ZJX

    1pc

    -

    1pc

    SRK-ZJ

    1pc

    -

    1pc

    -

    1pc

    1pc

    1pc

    -

    1pc

    First in the world

    CouplingCell wall

    Filter �ber

    Enzyme EnzymeBacterium

    Powerful sterilizing effect

    Enzyme's sterilizing mechanism

    Sterilization Mechanism

    -COOH

    H2N-

    Protein structure of allergen

    Urea Enzyme

    A molecule is decomposed

    Slack of high order structure Reduction in a molecule

    Inac

    tivat

    ion

    rate

    (%)

    100

    50

    0

    83.5%93.6%

    72.7%83.5%

    99.9% 99.0%

    Rate of inactivation against allergens collected on the �lter

    House dust mite*1 *1 *2 *2 *3 *3

    A species of mite Cedar pollen Epithelium of cat Virus i Virus p

    Photocatalytic Washable Deodorizing Filter

    Allergen Clear Filter

    Filter Indoor Unit

    Used in models

    *1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

    Air

    �o

    w

    Conventional Filter Enzyme Filter

    Analysis ZoneAnalysis Zone

    Natural Enzyme Filter

    SRF-ZJXSRK-ZKSRK-ZJX

    1pc

    -

    1pc

    SRK-ZJ

    1pc

    -

    1pc

    -

    1pc

    1pc

    1pc

    -

    1pc

    First in the world

    CouplingCell wall

    Filter �ber

    Enzyme EnzymeBacterium

    Powerful sterilizing effect

    Enzyme's sterilizing mechanism

    Sterilization Mechanism

    -COOH

    H2N-

    Protein structure of allergen

    Urea Enzyme

    A molecule is decomposed

    Slack of high order structure Reduction in a molecule

    Inac

    tivat

    ion

    rate

    (%)

    100

    50

    0

    83.5%93.6%

    72.7%83.5%

    99.9% 99.0%

    Rate of inactivation against allergens collected on the �lter

    House dust mite*1 *1 *2 *2 *3 *3

    A species of mite Cedar pollen Epithelium of cat Virus i Virus p

    Photocatalytic Washable Deodorizing Filter

    Allergen Clear Filter

    Filter Indoor Unit

    Used in models

    *1 Test method: ELISA colorimetric method / ELISA �uorescent method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*2 Test method: ELISA colorimetric method Laboratory: Independent administrative agency national hospital mechanism Sagamihara Hospital, No.1536*3 Test method: TCID (Infection value 50%) Laboratory: Foundation of Kitazato Environmental Science Center, No.15-0145

    Air

    �o

    w

    Conventional Filter Enzyme Filter

    Analysis ZoneAnalysis Zone

    Natural Enzyme Filter

    SRF-ZJXSRK-ZKSRK-ZJX

    1pc

    -

    1pc

    SRK-ZJ

    1pc

    -

    1pc

    -

    1pc

    1pc

    1pc

    -

    1pc

    First in the world

    Allergen clear � lterThis is the original and only technology to control the temperature and humidity for inactivating allergens

    Enzyme + Urea deactivates allergens and kills bacteriaThe allergen clear � lter deactivates pollen lice and allergens that live on cat skin etc. The deactivation secret is the Enzyme-urea compound. It deactivates not only allergens but some bacteria, moulds and viruses. Even if allergen, mould, virus or bacteria � y off the � lter they are deactivated so the air in your room is kept fresh.

    Natural enzyme � lter Helps to destroy fungi and bacteria, also effective on viruses and allergenic compounds (Cat hair, dust mite, pollen etc.)

    Enzyme � lterThe enzymes used in these � lters are naturally occurring lytic enzymes. Lytic enzymes attack cell walls of microorganisms trapped on the � lter and destroy them. The Natural Enzyme Filter will clean and sanitize air passing through it.

    Photocatalytic washable deodorizing � lterThe deodorizing ability of this filter can be easily restored simply by cleaning and exposing to sunlight

    This � lter will keep the air fresh by deodorizing the molecules that cause odours. The deodorizing effect can be restored by washing with water and then drying under the sun. This � lter maintains its deodorizing effect even after many repeat uses.

  • MULTI series Air Conditioners 2013

    14 Ceiling Concealed Type.

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control Wireless Remote Control

    RCN-TC-24W-ER

    SRR25~60VF

    Ceiling concealed type (SRR)

    Models SRR25ZJ-S, 35ZJ-S, 50ZJ-S, 60ZJ-S

    455

    253

    325.4

    67035 35

    515

    3030

    (Sus

    pens

    ion b

    olts p

    itch)

    (Suspension bolts pitch)

    Control Box

    D

    E

    D

    C

    B

    Suspension bolts

    Drain piping

    Liquid piping

    VP166.35 1 4" Flare

    Model

    Gas pipingA

    Symbol

    12.7 1 2"

    Content

    SRR25ZJ-S,

    9.52 3 8"

    SRR50ZJ-S,

    M8

    Flare Flare

    35ZJ-S 60ZJ-S

    E Power supply intake 35

    Option

    Wired remote controllerWireless remote controller

    120 196015

    017.3

    Unit:mm

    150

    13575

    38

    Terminal block

    Air inlet

    Air outlet B

    AC

    FIG.B

    Note 1 The model name label is attached on the lid of the control box.

    2 It takes the interface kit SC-BIKN-Eto connect the wired remote controller.

    236

    FIG.A

    8- 2.8Holes for tapping screws 4

    7.501047

    230

    11.2

    10522090220105

    4117

    019

    30

    100540100

    5214

    830

    174.

    430

    .3

    70318.5 18.5

    FIG.A(Air inlet from lower)

    In case of filter guide installed(normal condition)

    6-M4For hanger plate

    177

    21

    4847528

    670

    2012

    0

    32

    4040

    35 35

    FIG.B(Air inlet from rear)

    In case of filter guide installed(option)

    9- 2.8Holes for tapping screws 4

    Holes for tapping screws 4

    710

    10 24

    168 168 168 168

    160

    40

    190

    15

    15 15

    1113

    1024

    5- 3.3( Mark only)

    In case of filter guide taken off

    11- 2.8Holes for tapping screws 4

    710

    168 168 168 168

    69423

    10 10

    23

    2424

    2080

    8040

    150

    15 15

    203.

    711

    .3

    In case of rear panel taken off

    Standard Equipment

  • 15

    PR

    OD

    UC

    TS

    Ceiling Cassette.

    RCN-TC-24W-ER

    wireless remote control

    Fits into standard 600 x 600 ceiling

    Previous(Cooling/Heating)

    New(Cooling)

    New(Heating)

    36

    35

    34

    33

    32

    31

    30

    29

    28

    27

    26

    25

    (dB)

    35dB

    30dB

    32dB

    5dBDown

    3dBDown

    Flexible hose

    248mm600mm

    FDTC25~60VF

    OA OAPanel

    300mm

    Ceiling surface

    Indoor Unit FDTC

    OA Spacer

    Joint Duct

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control

    Wireless Remote Control

    RCN-TC-24W-ER

    RCN-TC-24W-ER

    wireless remote control

    Fits into standard 600 x 600 ceiling

    Previous(Cooling/Heating)

    New(Cooling)

    New(Heating)

    36

    35

    34

    33

    32

    31

    30

    29

    28

    27

    26

    25

    (dB)

    35dB

    30dB

    32dB

    5dBDown

    3dBDown

    Flexible hose

    248mm600mm

    FDTC25~60VF

    OA OAPanel

    300mm

    Ceiling surface

    Indoor Unit FDTC

    OA Spacer

    Joint Duct

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control

    Wireless Remote Control

    RCN-TC-24W-ER

    RCN-TC-24W-ER

    wireless remote control

    Fits into standard 600 x 600 ceiling

    Previous(Cooling/Heating)

    New(Cooling)

    New(Heating)

    36

    35

    34

    33

    32

    31

    30

    29

    28

    27

    26

    25

    (dB)

    35dB

    30dB

    32dB

    5dBDown

    3dBDown

    Flexible hose

    248mm600mm

    FDTC25~60VF

    OA OAPanel

    300mm

    Ceiling surface

    Indoor Unit FDTC

    OA Spacer

    Joint Duct

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control

    Wireless Remote Control

    RCN-TC-24W-ER

    RCN-TC-24W-ER

    wireless remote control

    Fits into standard 600 x 600 ceiling

    Previous(Cooling/Heating)

    New(Cooling)

    New(Heating)

    36

    35

    34

    33

    32

    31

    30

    29

    28

    27

    26

    25

    (dB)

    35dB

    30dB

    32dB

    5dBDown

    3dBDown

    Flexible hose

    248mm600mm

    FDTC25~60VF

    OA OAPanel

    300mm

    Ceiling surface

    Indoor Unit FDTC

    OA Spacer

    Joint Duct

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control

    Wireless Remote Control

    RCN-TC-24W-ER

    RCN-TC-24W-ER

    wireless remote control

    Fits into standard 600 x 600 ceiling

    Previous(Cooling/Heating)

    New(Cooling)

    New(Heating)

    36

    35

    34

    33

    32

    31

    30

    29

    28

    27

    26

    25

    (dB)

    35dB

    30dB

    32dB

    5dBDown

    3dBDown

    Flexible hose

    248mm600mm

    FDTC25~60VF

    OA OAPanel

    300mm

    Ceiling surface

    Indoor Unit FDTC

    OA Spacer

    Joint Duct

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control

    Wireless Remote Control

    RCN-TC-24W-ER

    RCN-TC-24W-ER

    wireless remote control

    Fits into standard 600 x 600 ceiling

    Previous(Cooling/Heating)

    New(Cooling)

    New(Heating)

    36

    35

    34

    33

    32

    31

    30

    29

    28

    27

    26

    25

    (dB)

    35dB

    30dB

    32dB

    5dBDown

    3dBDown

    Flexible hose

    248mm600mm

    FDTC25~60VF

    OA OAPanel

    300mm

    Ceiling surface

    Indoor Unit FDTC

    OA Spacer

    Joint Duct

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control

    Wireless Remote Control

    RCN-TC-24W-ER

    Taking outside air insideOA Spacer TC-OAS-E (option)Joint Duct TC-OAD-E (option)

    Utilizing OA spacer which comes as optional equipment, outside air can be taken inside.

    Using 1 joint duct: OA comes up to 1.3m3/min.Using 2 joint ducts: OA comes from 1.3 to 2.6m3/min.

    Quiet operation(Sound Pressure level in the Lo mode)

    “CLEARER”air fl owNew shape & angled louver redirects the air current away from the ceiling, to reduce ceiling stains

    Easy installation For wireless control simply insert the infrared receiver kit on a corner of the panel

    Compact and convenient 600mm drain pumpDrain can be discharged upward by 600 mm from the ceiling surface close to the indoor unit.It allows a piping layout with a high degree of freedom depending on the installation location.

    600 x 600 ceilingIndoor unit size (W:570 x D:570) brings easy installation for 600 x 600 ceiling and Panel size (700 x 700) is suitable for 600 x 600 ceiling. Height is one of the industry's lowest level at 248mm and weight is 16.5kg only.

  • MULTI series Air Conditioners 2013

    16 Floor Standing.

    Right

    Left

    Rear

    Left rear

    Left downward

    Downward

    Right

    Left

    Rear

    Left rear

    Left downward

    Downward

    Right

    Left

    Rear

    Left rear

    Left downward

    Downward

    Right

    Left

    Rear

    Left rear

    Left downward

    Downward

    Sophisticated design With a classy semi fl at front panel in chic white, this series fi ts in all kinds of rooms and creates a relaxing atmosphere. Choice of wall hanging, � oor standing or behind gallery installation is available.

    Auto air outlet selectionHeating operation: When both lower and upper outlets operation and the Auto fan speed mode is selected, the lower outlet will be kept closed for twenty minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets. That state will be maintained until the switch is turned off. Automatic adjustment of lower air outlet direction prevents stirring up of warm air and keeps optimum comfort at � oor level.

    Cooling operation: When both lower and upper outlets operation is selected in Cooling or Dry operation, both outlets are kept open for sixty minutes after the start or until room temperature is below set point. Then the air outlet will change to the upper outlet. That state will be maintained until unit is switched off. In case both outlets operation with Auto fan speed mode is selected, the upper outlet will be kept closed for ten minutes after the start or until room temperature is close to reaching the set point. Then the air outlet will change to both outlets in order to spread comfort air to every corner.

    Easy installation Piping and drain hose connection can be selected out of 6-directions.

    Convenient to use operation Besides on/off operation, simultaneous lower and upper air outlets or upper outlet can be selected by the air � ow direction button. Further control can be selected on the remote control.

    Convenient to use operation Besides on/off operation, simultaneous lower and upper air outlets or upper outlet can be selected by the air � ow direction button. Further control can be selected on the remote control.

    SRF25ZJX-S, SRF35ZJX-S, SRF50ZJX-SSRF25~50ZJX

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control Wireless Remote Control

    RCN-TC-24W-ER

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control Wireless Remote Control

    RCN-TC-24W-ER

  • PR

    OD

    UC

    TS

    17

    Ceiling Concealed Type Medium Static.

    Low profi le The height of FDUM50 model is only 280mm.

    600mm drain pumpDrain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location.

    Improved servicing Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance is available from the right side or from beneath.

    FDUM50VF

    RC-E5RC-EX1A

    Wired

    RCH-E3 RCN-KIT3-E

    WirelessRemote control (Option)

    280

    Flexible hose

    less than 600mm

    FDUM50VF

    RC-E5RC-EX1A

    Wired

    RCH-E3 RCN-KIT3-E

    WirelessRemote control (Option)

    280

    Flexible hose

    less than 600mm

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control Wireless Remote Control

    RCN-KIT3-E

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control Wireless Remote Control

    RCN-KIT3-EFDUM50VF

    RC-E5RC-EX1A

    Wired

    RCH-E3 RCN-KIT3-E

    WirelessRemote control (Option)

    280

    Flexible hose

    less than 600mm

    Maintenance hole

    Pipe

    Fan unitUnit

    Service space

    FDUM50VF

  • MULTI series Air Conditioners 2013

    18 Ceiling Suspended.

    Wireless remote control

    RCN-E-E

    RC-E5

    Wired remote control

    RCH-E3

    Wireless remote control

    RCN-E-E

    RC-E5

    Wired remote control

    RCH-E3

    Rear

    Right

    Up

    Height250mm

    Rear

    Right

    Up

    Height210mm

    Easy installationIncreased freedom of a piping layoutThe refrigerant pipe from the unit can be arranged in three directions, rear, right and up. The drain pipe can be arranged in two directions, left and right. This will allow a free layout of piping for various installation conditions. The unit can only be serviced from below.

    Compact and modern designAll models � t compactly on the ceiling. Height is 210mm. Elegant, modern design featuring rounded edges gives the room a comfortable atmosphere.

    FDEN50VF

  • 19

    PR

    OD

    UC

    TS

    Control Options.

    Wired Remote Control Wireless Remote Option Super Link Network

    Model Interface Wired Remote Control Infrared Kit Interface Wired Remote Control

    SRK**ZJ-S

    SC-BIKN-E

    Options RC-EX1A RC-E5 RCH-E3

    Not requiredSC-BIKN-E

    SC-ADNA-EOptions RC-EX1A RC-E5 RCH-E3

    SRK**ZJ-S1

    SRK**ZJX-S

    SRK**ZJX-S1

    SRK71ZK-S

    SRF**ZJX-S

    SRF**ZJX-S1

    SRR**ZJ-S

    FDUM50VF

    Not required

    RCN-KIT3-E

    SC-ADNA-EFDTC**VF RCN-TC-24W-ER

    FDEN50VF RCN-E-E

    CnT terminal is equipped

    XR5

    CnT

    XR1~4 : DC12v XR5 : 220~240V

    XR3

    XR1

    XR2

    XR4

    XR5

    XR1

    XR2

    XR3

    XR4

    output1 (run)

    output2 (heat)

    output3 (comp on)

    output4 (alarm)

    common

    Powersource

    in put

    Remote surveillance system

    Card key on-off

    HOTEL

    HO

    TE

    L

    Refrigerant Pipe Length Limit - The maximum piping length of the refrigerant pipes for the outdoor units, and the maximum

    height difference for the outdoor units are as shown below.

    length for one indoor unittotal length for all roomslower installation spot of the indoor unit (A)upper installation spot of the indoor unit (B)maximum height difference of the indoor units (C)precharged to refrigerant pipe length

    heightdifference

    under 25munder 70munder 20munder 20munder 25m

    40m

    B

    A

    C

    SCM40ZJ-S SCM50/60ZJ-S SCM71/80ZJ-S

    B

    A

    C

    SCM100ZJ-S

    under 25munder 30munder 15munder 15munder 25m

    30m

    under 25munder 40munder 15munder 15munder 25m

    40m

    SCM40ZJ SCM50/60ZJ SCM71/80ZJ

    under 25munder munder munder munder m

    m

    under 25munder munder munder munder m

    m

    SCM100ZJ SCM125ZJ

    B

    A

    C

    B

    A

    CB

    A

    C

    SCM125ZJ-S

    Maximum refrigeration pipe run metres SCM40ZJ SCM50/60ZJ SCM71/80ZJ SCM100/125ZJ

    length for one indoor unit 25

    total length for all rooms 30 40 70 90

    height difference

    lower installation spot of the indoor unit (A)15 20

    upper installation spot of the indoor unit (B)

    maximum height difference of the indoor units (C) 25

    pre charged to refrigerant pipe length 30 40 50

    CnT terminal is equiped

  • MULTI series Air Conditioners 2013

    20 Inverter Multi-Split System.

    Wall mounted type SRK Ceiling concealed type SRR 4way ceiling cassette type FDTC

    Floor type SRF Ceiling suspended type FDEN

    Duct connected type FDUMDuct connected type FDUM

    SCM-ZJThe multi system allows a single outdoor unit to service up to six indoor units.

    Individual refrigerant circuit for each indoor unit

    Outdoor Unit

    Floor type SRF

    SCM40ZJ-S1 / SCM50ZJ-S1SCM60ZJ-S1 SCM71ZJ-S1 / SCM80ZJ-S1 SCM100ZJ-S1/ SCM125ZJ-S1

  • PR

    OD

    UC

    TS

    21

    SCM

    40ZJ

    -SSC

    M50

    ZJ-S

    1SC

    M60

    ZJ-S

    1SC

    M71

    ZJ-S

    1SC

    M80

    ZJ-S

    1SC

    M10

    0ZJ-

    S1SC

    M12

    5ZJ-

    S1

    2 Ro

    oms

    2~3

    Room

    s2~

    4 Ro

    oms

    4~5

    Room

    s4~

    6 Ro

    oms

    Pow

    er S

    uppl

    yOu

    tdoo

    r1

    Phas

    e 23

    0V 5

    0Hz

    Rate

    d Ca

    paci

    ty

    Cool

    ing

    T1kW

    4.0(

    1.8~

    5.9)

    5.0(

    1.8~

    7.1)

    6.0(

    1.8~

    7.5)

    7.1(

    1.8~

    8.8)

    8.0(

    1.8~

    9.2)

    1012

    .5

    Heat

    ing

    H1kW

    4.5(

    1.4~

    6.9)

    6.0(

    1.4~

    7.5)

    6.8(

    1.5~

    7.8)

    8.6(

    1.5~

    9.4)

    9.3(

    1.5~

    9.8)

    1213

    .5

    Elec

    tric

    al In

    put

    Cool

    ing

    T1kW

    0.84

    1.

    08

    1.43

    1.

    74

    2.16

    2.

    863.

    9

    Heat

    ing

    H1kW

    0.90

    1.

    31

    1.51

    2.

    00

    2.26

    2.

    933.

    25

    EER

    Cool

    ing

    T14.

    76

    4.63

    4.

    20

    4.08

    3.

    70

    3.5

    3.21

    COP

    Heat

    ing

    H15.

    00

    4.58

    4.

    50

    4.30

    4.

    12

    4.1

    4.15

    Curr

    ent

    Cool

    ing

    T1A

    3.7

    4.7

    6.5

    7.6

    9.4

    12.4

    17

    Heat

    ing

    H1A

    45.

    86.

    88.

    810

    12.8

    14.1

    Rec

    Circ

    uit B

    reak

    erA

    25A

    Soun

    d Po

    wer

    Lev

    el (J

    IS C

    9612

    )Co

    olin

    g (O

    utdo

    or)

    dB (A

    )60

    6263

    6566

    6869

    Heat

    ing

    (Out

    door

    )dB

    (A)

    6265

    6566

    6671

    72

    Exte

    rnal

    Dim

    ensi

    ons

    (HXW

    XD)

    mm

    640X

    850X

    290

    750X

    880X

    340

    945X

    970X

    370

    Net w

    eigh

    tOu

    tdoo

    rkg

    4748

    4962

    92

    Refr

    iger

    ant P

    ipin

    g

    Liqu

    id L

    ine

    mm

    Ø6.3

    5 X

    2Ø6

    .35

    X 3

    Ø6.3

    5 X

    3Ø6

    .35

    X 4

    Ø6.3

    5 X

    4Ø6

    .35

    X 5

    Ø6.3

    5 X

    6

    Gas

    Line

    mm

    Ø9.5

    2 X

    2Ø9

    .52

    X 3

    Ø9.5

    2 X

    3Ø9

    .52

    X 4

    Ø9.5

    2 X

    4Ø9

    .52

    X 5

    Ø9.5

    2 X

    6

    Unio

    nm

    m(Ø

    9.52

    Ø12

    .7) X

    1(Ø

    9.52

    Ø12

    .7) X

    2(Ø

    9.52

    Ø12

    .7) X

    2(Ø

    9.52

    Ø12

    .7) X

    2(Ø

    9.52

    Ø12

    .7) X

    2(Ø

    9.52

    Ø12

    .7) X

    2

    Conn

    ectio

    n M

    etho

    dFl

    are

    conn

    ectio

    n

    Refr

    iger

    ant R

    410A

    Volu

    me

    kg2.

    02.

    53.

    156

    Pre-

    Char

    ged

    30 m

    trs

    40 m

    trs

    50 m

    trs

    Indo

    or U

    nit C

    ombi

    natio

    n

    SRK*

    ZJS/

    S1

    kW

    2.0,

    2.5,

    3.5

    2.0,

    2.5,

    3.5,

    5.0

    2.0,

    2.5,

    3.5,

    5.0

    SRK*

    ZJX

    2.0,

    2.5,

    3.5

    2.0,

    2.5,

    3.5

    2.0,

    2.5,

    3.5

    2.0,

    2.5,

    3.5

    SRK*

    ZJX-

    S15.

    05.

    0,6.

    05.

    0,6.

    0

    SRK*

    ZK-S

    7.1

    SRF*

    ZJX

    2.5,

    3.5

    2.5,

    3.5

    2.5,

    3.5

    SRF*

    ZJX-

    S15.

    05.

    05.

    0

    SRR*

    ZJ2.

    5,3.

    52.

    5,3.

    5,5.

    02.

    5,3.

    5,5.

    0,6.

    0

    FDTC

    *VD

    2.5,

    3.5

    2.5,

    3.5,

    5.0

    2.5,

    3.5,

    5.0,

    6.0

    FDUM

    *VF

    5.0

    FDEN

    *VF

    5.0

    Indo

    or U

    nit C

    onne

    ctio

    n2

    Units

    2 to

    3 U

    nits

    2 to

    4 U

    nits

    4 to

    5 U

    nits

    4 to

    6 U

    nits

    Indo

    or C

    onne

    ctio

    n Ca

    paci

    tykW

    4.0k

    W to

    6.0

    kW4.

    0kW

    to 8

    .5kW

    4.0k

    W to

    11.

    0kW

    4.0k

    W to

    12.

    6kW

    4.0k

    W to

    13.

    5kW

    8.0

    kW to

    16k

    W8.

    0kW

    to 1

    9.5k

    W

    Note

    s1

    Rate

    d da

    ta is

    mea

    sure

    d us

    ing

    SRK*

    ZJX

    indo

    or u

    nits

    to m

    atch

    the

    outd

    oor u

    nit c

    apac

    ity2

    Curr

    ently

    ther

    e is

    no

    ener

    gy la

    belli

    ng s

    tand

    ard

    for t

    his

    type

    of p

    rodu

    ct

    3 Th

    e kW

    out

    put c

    apac

    ity, e

    lect

    rical

    inpu

    t, cu

    rren

    t and

    reco

    mm

    ende

    d ci

    rcui

    t bre

    aker

    are

    indi

    cate

    d at

    rate

    d kW

    out

    put c

    apac

    ity. E

    lect

    rical

    wor

    k m

    ust b

    e ca

    rrie

    d ou

    t by

    a su

    itabl

    y qu

    ali�

    ed p

    erso

    n an

    d co

    mpl

    y to

    all

    elec

    tric

    al

    stan

    dard

    s an

    d lo

    cal r

    egul

    atio

    ns.

  • MULTI series Air Conditioners 2013

    22 Multi System Indoor Unit.

    Series

    SPECIFICATIONSItem Model

    Cooling capacityHeating capacity

    Sound power level

    Sound pressure level

    kWkW

    dB(A)dB(A)dB(A)dB(A)

    l/s

    mmkg

    mmmm

    CoolingHeatingCoolingHeatingCoolingHeating

    Liquid lineGas line

    2.53.15558

    Hi:41 Me:31 Lo:22Hi:41 Me:34 Lo:27

    208-150-83216-166-125

    15

    ø 6.35

    SRK25ZJX-S3.54.55859

    Hi:43 Me:33 Lo:22Hi:42 Me:35 Lo:27

    225-158-83233-183-134

    SRK35ZJX-S5.05.86062

    Hi:47 Me:40 Lo:27Hi:48 Me:40 Lo:33

    225-183-133275-241-175

    SRK50ZJX-S6.06.86262

    Hi:51 Me:41 Lo:29Hi:48 Me:41 Lo:34

    241-208-141283-250-183

    SRK60ZJX-S

    ø 12.7

    SRK20ZJX-S2.02.55354

    Hi:39 Me:30 Lo:21Hi:38 Me:33 Lo:25

    191-133-83200-158-116

    SCM40~125ZJ-S1 SCM60~125ZJ-S1SCM50~125ZJ-S1

    309X890X220

    Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1

    ø 9.52

    *

    *

    The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

    * Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

    Exterior dimensions (HXWXD)Net weightClean �lter

    Piping

    OUTDOOR UNITS TO BE COMBINED

    Air �ow Indoor

    FUNCTIONComfortable Functions

    Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Lateral

    SwingAuto

    Positioning of

    installation

    Others

    RestartAutoBack-up

    SwitchLuminous

    24h ION

    Maintenance & Prevention Functions

    MC DiagnosticSelf Detachable

    AllergenFilterAllergenFilterAllergenFilter

    SUNFilterSUNFilterSUNFilter

    Self CleanOperationSelf CleanOperationSelf CleanOperation

    Convenient & Economy FunctionsOn Timer

    24h TimerDRY

    OFF Timer SleepEconomy

    SRK-ZJXHigh COP wall mount type

    SRR-ZJCeiling concealed type

    SPECIFICATIONS

    SRR25ZJ-S SRR35ZJ-S SRR50ZJ-S SRR60ZJ-SModelCooling capacityHeating capacity

    Sound power level

    Sound pressure level

    Air �ow Q’ty (Hi)

    Exterior dimensions(HXWXD)Net weight

    Piping

    OUTDOOR UNITS TO BE COMBINED

    kWkW

    dB(A)dB(A)dB(A)dB(A)

    l/s

    mmkg

    mmmm

    CoolingHeatingCoolingHeatingCoolingHeating

    2.53.45455

    Hi:40 Me:35 Lo:29Hi:41 Me:38 Lo:31

    142167

    3.54.55657

    Hi:42 Me:37 Lo:30Hi:43 Me:40 Lo:32

    150183

    5.05.86060

    Hi:48 Me:42 Lo:33Hi:48 Me:45 Lo:36

    175217

    6.06.86363

    Hi:51 Me:44 Lo:35Hi:51 Me:47 Lo:38

    208250

    230x740x455

    ø 6.35ø 9.52

    23

    SCM40~125ZJ-S1

    *

    *

    ø 6.35ø 12.7

    22

    SCM60~125ZJ-S1SCM50~125ZJ-S1

    Liquid lineGas line

    FUNCTIONComfortable Functions Maintenance & Prevention Functions

    MC DiagnosticSelfSelf CleanOperationSelf CleanOperationSelf CleanOperation

    Others

    RestartAutoBack-up

    SwitchLuminous

    Convenient & Economy FunctionsOn Timer

    24h TimerDRY

    OFF Timer SleepEconomy

  • PR

    OD

    UC

    TS

    23

    Multi System Indoor Unit.

    FUNCTIONComfortable Functions Convenient & Economy Functions

    On Timer24h Timer

    Economy

    DRY

    OFF Timer SleepOthers

    RestartAutoBack-up

    SwitchLuminous

    Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Air outlet

    selection

    Maintenance & Prevention Functions

    MC DiagnosticSelf DetachableEnzymeFilter

    EnzymeFilter

    EnzymeFilter

    SUNFilterSUNFilterSUNFilter

    Self CleanOperationSelf CleanOperationSelf CleanOperation

    SPECIFICATIONSModel

    Cooling capacityHeating capacity

    Sound power level

    Sound pressure level

    kWkW

    dB(A)dB(A)dB(A)dB(A)

    l/s

    mmkg

    mmmm

    CoolingHeatingCoolingHeatingCoolingHeating

    SRF35ZJX-S5.05.85858

    Hi:46 Me:42 Lo:32Hi:47 Me:41 Lo:33

    191-160-110200-166-126

    SRF50ZJX-S3.54.55252

    Hi:41 Me:34 Lo:28Hi:41 Me:36 Lo:31

    153-130-106178-138-123

    SRF25ZJX-S2.53.45151

    Hi:40 Me:32 Lo:26Hi:40 Me:35 Lo:28

    150-126-96175-136-110

    Liquid lineGas line

    600X860X23819

    ø 6.35

    *

    *

    The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

    * Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

    Natural Enzyme FilterX1 Photocatalytic Washable Deodorizing FilterX1

    SCM40~125ZJ-S1 SCM50~125ZJ-S1

    ø 9.52 ø 12.7

    Exterior dimensions (HXWXD)Net weightClean �lter

    Piping

    OUTDOOR UNITS TO BE COMBINED

    18

    Air �ow Indoor

    SRF-ZJXFloor type

    SRK-ZJ-S1Wall mount type

    Series

    SPECIFICATIONSModel

    Cooling capacityHeating capacity

    Sound power level

    Sound pressure level

    kWkW

    dB(A)dB(A)dB(A)dB(A)

    l/s

    mmkg

    mmmm

    CoolingHeatingCoolingHeatingCoolingHeating

    Liquid lineGas line

    2.53.25055

    Hi:34 Me:28 Lo:21Hi:39 Me:31 Lo:24

    131-100-83176-108-85

    9.5

    ø 6.35

    SRK25ZJ-S/S13.54.05859

    Hi:42 Me:32 Lo:22Hi:43 Me:37 Lo:25

    168-106-83213-156-101

    SRK35ZJ-S/S15.05.86161

    Hi:46 Me:37 Lo:26Hi:45 Me:37 Lo:31

    188-130-88225-170-125

    SRK50ZJ-S/S1

    ø 12.7

    SRK20ZJ-S/S12.02.74952

    Hi:33 Me:27 Lo:21Hi:36 Me:31 Lo:24

    130-93-80163-105-83

    SCM40~125ZJ-S1 SCM50~125ZJ-S1

    294X798X229

    Allergen Clear Filter X 1, Photocatalytic Washable Deodorizing Filter X 1

    ø 9.52

    *

    *

    Exterior dimensions (HXWXD)Net weightClean �lter

    Piping

    OUTDOOR UNITS TO BE COMBINED

    Air �ow Indoor

    FUNCTIONComfortable Functions

    Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Lateral

    SwingAuto

    Positioning of

    installation

    Others

    RestartAutoBack-up

    SwitchLuminous

    Maintenance & Prevention Functions

    MC DiagnosticSelf Detachable

    AllergenFilterAllergenFilterAllergenFilter

    SUNFilterSUNFilterSUNFilter

    Self CleanOperationSelf CleanOperationSelf CleanOperation

    Convenient & Economy FunctionsOn Timer

    24h TimerDRY

    OFF Timer SleepEconomy

  • MULTI series Air Conditioners 2013

    24 Inverter Multi Split System.

    SRK-ZKWall mounted type

    Series

    SPECIFICATIONSItem Model

    Nominal cooling capacityNominal heating capacity

    Sound power level

    Sound pressure level

    kWkW

    dB(A)dB(A)dB(A)dB(A)

    CMM

    mmkg

    mmmm

    CoolingHeatingCoolingHeatingCoolingHeating

    SRK71ZK-S7.18.06061

    Hi:49 Me:45 Lo:39 Ulo:26Hi:46 Me:43 Lo:38 Ulo:35

    Hi:19.5 Me:17.5 Lo:14.0 Ulo:8.0Hi:21.5 Me:19.5 Lo:15.5 Ulo:14.0

    318x1098x24815

    Liquid lineGas line

    Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1 6.35 15.88

    *

    *

    The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

    * Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions.

    Exterior dimensions (HXWXD)Net weightClean �lter

    Piping

    OUTDOOR UNITS TO BE COMBINED

    Air �ow

    FUNCTIONComfortable Functions

    Others

    RestartAutoBack-up

    SwitchLuminous

    Maintenance & Prevention Functions

    MC DiagnosticSelf DetachableConvenient & Economy Functions

    On Timer24h TimerDRY

    OFF Timer SleepEconomy

    AllergenFilterAllergenFilterAllergenFilter

    SUNFilterSUNFilterSUNFilter

    Self CleanOperationSelf CleanOperationSelf CleanOperation

    Comfortable Air Flow FunctionsAuto Flap Memory UP/DOWN Lateral

    Swing

    Air Scroll24h ION

    SCM100/125ZJ-S1

    FDEN-VFCeiling suspended

    FDEN50VFItem ModelNominal cooling capacityNominal heating capacity

    Sound pressure level

    Air �ow

    Exterior dimensions (HxWxD)Net weightAir �lter

    Piping

    OUTDOOR UNITS TO BE COMBINED

    kWkW

    dB(A)dB(A)CMMCMMmmkg

    mmmm

    CoolingHeatingCoolingHeating

    5.05.8

    Hi:39 Me:38 Lo:37Hi:39 Me:38 Lo:37Hi:11 Me:9 Lo:7Hi:11 Me:9 Lo:7

    210x1070x69028

    Pocket Plastic net x 2 (Washable)

    *

    The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

    * Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. Powerful-Hi can be selected. Sound pressure level:Cooling dB(A):46 Heating:46, Air �ow:13CMM

    6.3512.7

    Liquid lineGas line

    SPECIFICATIONS

    FUNCTIONComfortable Functions Comfortable Air Flow Functions

    Auto Flap Memory UP/DOWNOthers

    RestartAutoBack-up

    Switch

    Maintenance & Prevention Functions

    MC DiagnosticSelfConvenient & Economy Functions

    On Timer24h TimerDRY

    OFF Timer Sleep

    SCM50~125ZJ-S1

    RC-E5 RCH-E3

    Wired Remote Control Wireless Remote Control

    RCN-E-E

  • PR

    OD

    UC

    TS

    25

    Inverter Multi Split System.

    FDTC-VF4way ceiling cassette type

    FDTC25VF FDTC35VF FDTC50VF FDTC60VF

    SPECIFICATIONS

    Item Model

    Nominal cooling capacityNominal heating capacity

    Sound pressure level

    Air �ow

    Exterior dimensions(HXWXD)

    Net weight

    Piping

    OUTDOOR UNITS TO BE COMBINED

    kWkW

    dB(A)dB(A)CMMCMMmmmmkgkg

    mmmm

    CoolingHeatingCoolingHeatingMain unitPanelMain unitPanelLiquid lineGas line

    2.53.4

    Hi:36 Me:32 Lo:29Hi:38 Me:33 Lo:29.5

    Hi:9 Me:8 Lo:6.5Hi:9.5 Me:8.5 Lo:7

    3.54.5

    Hi:40 Me:36 Lo:30Hi:42 Me:35 Lo:32Hi:9.5 Me:9 Lo:7Hi:10 Me:9 Lo:8

    5.05.8

    Hi:42 Me:36 Lo:30Hi:42 Me:36 Lo:32Hi:11.5 Me:9 Lo:7Hi:11.5 Me:9 Lo:8

    6.06.8

    Hi:46 Me:39 Lo:30Hi:46 Me:39 Lo:32Hi:13.5 Me:10 Lo:7Hi:13.5 Me:10 Lo:8

    248x570x57035x700x700

    153.5

    6.359.52

    6.3512.7

    *

    The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

    * Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. Powerful-Hi can be selected. Sound level dB(A):25VF(Cooling:38 Heating:39), 35VF(Cooling:41 Heating:43), 40/50/60VF(Cooling:47 Heating:47), Air �ow:25VF(Cooling:10 Heating:10.5), 35VF(Cooling:11 Heating:11.5), 50/60VF(Cooling:13.5 Heating:13.5)

    FUNCTIONComfortable Functions Comfortable Air Flow Functions

    Auto Flap Memory UP/DOWNOthers

    RestartAutoBack-up

    Switch

    Maintenance & Prevention Functions

    MC DiagnosticSelfConvenient & Economy Functions

    On Timer24h TimerDRY

    OFF Timer Sleep

    Fits into standard 600 x 600 ceiling

    SCM40~125ZJ-S1 SCM60~125ZJ-S1SCM50~125ZJ-S1

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control Wireless Remote Control

    RCN-TC-24W-ER

    FDUM-VFDucted connected-low/middlestatic pressure

    FDUM50VF

    SPECIFICATIONS

    Item Model

    Nominal cooling capacityNominal heating capacity

    Sound pressure level

    Air �ow

    Exterior dimensions (HxWxD)Net weightAir �lter

    Piping

    OUTDOOR UNITS TO BE COMBINED

    kWkW

    dB(A)dB(A)CMMCMMmmkg

    mmmm

    CoolingHeatingCoolingHeating

    5.05.8

    Hi:32 Me:29 Lo:26Hi:32 Me:29 Lo:26

    Hi:10 Me:9 Lo:8Hi:10 Me:9 Lo:8

    280x750x63529

    Procure locally

    *

    The data are measured under the following conditions(ISO-T1). Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB.

    * Indicates the value in an anechoic chamber.During operation these values are somewhat higher due to ambient conditions. Powerful-Hi can be selected. Sound pressure level dB(A):Cooling:37 Heating:37, Air �ow:13CMM

    6.3512.7

    Liquid lineGas line

    FUNCTIONComfortable Functions Others

    RestartAutoBack-up

    Switch

    Maintenance & Prevention Functions

    MC DiagnosticSelfConvenient & Economy Functions

    On Timer24h TimerDRY

    OFF Timer Sleep

    Filter KITUM-FL1EF (option)

    SCM50~125ZJ-S1

    RC-E5RC-EX1A RCH-E3

    Wired Remote Control Wireless Remote Control

    RCN-KIT3-E

  • MULTI series Air Conditioners 2013

    26 Dimension Outdoor Unit. Models SCM40ZJ-S, 45ZJ-S

    Symbol ContentA Service valve connection gas side 9.52 3 8" FlareB Service valve connection liquid side 6.35 1 4" FlareC Pipe cable draw-out holeD Drain discharge hole 20 x 3 places

    secalp4x01MelohtlobrohcnAE

    D

    BAC

    Service panel

    Terminal block

    E43

    .5286.4

    49.6

    290

    476203.1 510 136.9

    1431

    2.5

    5012

    13.5

    340

    640

    15

    850

    100.3

    42.7

    124.1 34.6

    2-16x12

    211

    42.7

    2020

    20

    103.2

    385.9 14.6

    17.965

    20

    L1

    L3Intake

    No obstaclesService space

    L2

    Intake

    Outlet

    Minimum installation space

    for electricalparts

    100

    600L2L3

    L1

    Examples of

    100

    Installation

    Dimensions

    Unit:mm

    Models SCM71ZJ-S1, 80ZJ-S1

    L1

    L3Intake

    L2

    Intake

    Outlet

    100

    600L2L3

    L1

    Examples of

    100

    Installation

    Dimensions

    Minimum installation space

    DTerminal block

    C

    E

    tnetnoClobmySA Service valve connection gas side 9.52 3 8" FlareB Service valve connection liquid side 6.35 1 4" FlareC Pipe cable draw-out holeD Drain discharge hole 20 x 3 places

    secalp 4 x 01Meloh tlob rohcnAE

    B

    A

    No obstaclesService space

    for electricalparts

    Unit:mm

    1560

    380

    1941

    8

    73880150 580 150 26

    340

    2-R7.5

    223

    47.5

    310

    61

    61

    110.4

    52

    185 10

    2475

    0

    214.4

    5231

    8.452

    422.4

    52

    20

    Model SCM125ZJ-S1

    9.52 3 8" Flare

    Content

    C Pipe cable draw-out hole

    D

    E Anchor bolt hole

    Drain discharge hole

    Symbol

    B

    A Service valve connection gas side

    M10 x 4places

    20 x 3places

    Service valve connection liquid side 6.35 1 4" Flare

    L2L3

    L1300150

    OpenOpen150

    500Open

    3005

    Examples of

    Dimensions installation

    L1

    L3

    Intake

    Outlet

    Intake

    Minimum installation space

    spaceService

    L2

    No obstaclesService space

    for electricalparts

    D580

    76190

    60

    55

    20

    200

    262.8 325

    410

    4037

    040

    20

    Center of gravity

    945

    5211

    5.2 219.2

    5252

    5252

    531.2

    427.2

    323.2

    5263

    5.2

    393

    10

    E

    Center of gravity 26970

    15 15

    580

    177

    73

    B

    AC

    Terminal block Rear panel

    10170

    Models SCM50ZJ-S1, 60ZJ-S1

    Symbol ContentA Service valve connection gas side 9.52 3 8" FlareB Service valve connection liquid side 6.35 1 4" FlareC Pipe cable draw-out holeD Drain discharge hole 20 x 3 places

    secalp 4 x 01Meloh tlob rohcnAE

    D

    BAC

    Service panel

    Terminal block

    E

    L1

    L3Intake

    L2

    Intake

    Outlet

    100

    600L2L3

    L1

    Examples of

    100

    Installation

    Dimensions

    Minimum installation space

    No obstaclesService space

    for electricalparts

    Unit:mm

    43.5

    286.4

    49.6

    136.9

    1431

    2.5

    5012

    13.5

    340

    640

    15 100.3

    42.7

    Model SCM100ZJ-S1

    9.52 3 8" Flare

    Content

    C Pipe cable draw-out hole

    D

    E Anchor bolt hole

    Drain discharge hole

    Symbol

    B

    A Service valve connection gas side

    M10 x 4places

    20 x 3places

    Service valve connection liquid side 6.35 1 4" Flare

    L2L3

    L1300150

    OpenOpen150

    500Open

    3005

    Examples of

    Dimensions installation

    L1

    L3

    Intake

    Outlet

    Intake

    Minimum installation space

    spaceService

    L2

    No obstaclesService space

    for electricalparts

    D580

    76190

    60

    55

    20

    200

    262.8 325

    410

    4037

    040

    20

    Center of gravity

    945

    5211

    5.2 219.2

    5252

    5252

    531.2

    427.2

    323.239

    3

    10

    E

    Center of gravity970

    15 15

    177

    2658073

    B

    AC

    Terminal block Rear panel

    10170

    SCM40ZJ-S

    SCM71ZJ-S1 SCM80ZJ-S1

    SCM125ZJ-S1

    SCM50ZJ-S1 SCM60ZJ-S1

    SCM100ZJ-S1

  • 27

    SP

    EC

    IFIC

    ATIO

    NS

  • Because of our policy of continuous improvement, we reserve the right to make changes in all speci� cations without notice. E&OE.

    Australia: New Zealand: ABN 92 133 980 275 G.S.T. 105-673-620

    Phone: 1300 138 007 Fax: 1800 644 329 Phone: 0800 138 007 Fax: 09 442 5346

    NSW & Head Of� ce9C Commercial RoadKingsgrove NSW 2208PO Box 318 Kingsgrove NSW 1480

    Victoria2/24 Lakeside DriveBurwood East VIC 3151

    Queensland5/26 Flinders Parade North Lakes QLD 4509

    Western AustraliaUnit 3A 2 Mulgul Rd Malaga WA 6090PO Box 667 Belmont WA 6104

    AucklandUnit 2 100 Bush Road Albany 0632PO Box 300552 Albany 0632

    www.mhiaa.com.au www.mhiaa.co.nz

    MRE SPARE PARTS www.mrespareparts.com.au Tel: +61 (0) 2 9600 7444 Fax: +61 (0) 2 9600 8044

    Our Air Conditioning & Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial-use air conditioners (including heat pumps).

    ISO9001

    BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd.

    Air-conditioning & Refrigeration Systems HeadquartersCerti�ed ISO 9001

    Certi�cate number : JQA-0709

    Our Air Conditioning & Refrigeration Systems Headquarters has been assessed and found to comply with the requirements of ISO14001.

    ISO14001

    BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd.

    Air-conditioning & Refrigeration Systems HeadquartersCerti�ed ISO 14001

    Certi�cate number : JQA-EM0256

    MITSUBISHI HEAVY INDUSTRIES-MAHAJAK AIR CONDITIONERS CO., LTD.

    Certi�ed ISO 9001Certi�cate Number : 04100 1998 0813

    MITSUBISHI HEAVY INDUSTRIES-MAHAJAK AIR CONDITIONERS CO.,LTD.

    Certi�cate Number : 04104 1998 0813 E5

    ISO 14001Certi�cate 04104 1998 0813 E5

    MH

    IAA

    306_

    MU

    LTI 1

    2_20

    12

    Before starting use

    Heating performanceThe heating performance values (kW) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insuf� cient, use other heating appliances as well.

    Indication of sound valuesThe sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing.

    Use in oil atmosphereAvoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break.

    Use in acidic or alkaline atmosphereIf this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere.

    Use in places with high ceilingsIf the ceiling is high, install a circulator to improve the heat and air � ow distribution when heating.

    Refrigerant leakageThe refrigerant (R410A) used for Air conditioner is non-toxic and non� ammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc.

    Use in snowy areasTake the following measures when installing the outdoor unit in snowy areas.

    Snow preventionInstall a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit.

    Snow pilingIn areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit.

    Automatic defrosting deviceIf the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The “Automatic defrosting device” will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again.

    Servicing the air-conditionerAfter the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist.

    Safety PrecautionsAir-conditioner usage targetThe air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, computer server rooms, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur.

    Before useAlways read the “User,s Manual” thoroughly before starting use.

    InstallationAlways commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and � res. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base.

    Usage placeDo not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, � ow or accumulate, or places containing carbon � bers could lead to � res.

    Only persons that are quali� ed and licensed are permitted to install and service products that contain refrigerants in Australia, go to www.arctick.org. Suitable access for service must be provided in compliance with industry standards and local regulations.

    MHIAA is proudly sponsoring Monika’s Doggie Rescue