Introducing DAQ

download Introducing DAQ

of 16

Transcript of Introducing DAQ

  • 8/2/2019 Introducing DAQ

    1/16

    Introducing LMS SCADAS Lab

  • 8/2/2019 Introducing DAQ

    2/16

    copyrightLMSInternational-2010

    2

    LMS SCADAS LabState-of-the-art Laboratory data acquisition system

    Introducing the new member of the SCADAS Family

    SCADASLab

    Measurement Power&Data Quality

    OptimizedInvestment

    &Reliability

    Increased data acquisition performance

    more channels at higher sampling rates

    Superior data quality for effective test execution

    Efficiency&

    Productivity

    Fit-for-purpose laboratorysolution

    AC power supply Low noise, fan-cooled

    19 frame

    Based on SCADAS Mobiletechnology

    Several years proven trackrecord

    Effective test set-up

    Single device measures everything signal conditioning power

    Seamless integration with Test.Labapplications

    Flexibility in transducer connectivity

    Introducing Lab-Mobility

    Mix & match compatibility between

    SCADAS Mobile/Recorder andSCADAS Lab frames

  • 8/2/2019 Introducing DAQ

    3/16

    copyrightLMSInternational-2010

    3

    LMS SCADAS LabState-of-the-art Laboratory data acquisition system

    19 frame for indoor useSegment displays withdynamic content

    High channel density, up to160 channels per frame

    SCADAS Mobile technology inside,featuring high throughput rate &

    superior data quality

    Wide range of signal conditioning &flexibility in connectivity (CAMAC,

    BNC, Sub-D)

  • 8/2/2019 Introducing DAQ

    4/16

    copyrightLMSInternational-2010

    4

    Sustained14Msamples/sor 42 Mbyte/sthroughput rateindependent offrame &

    channel count

    LMS SCADAS LabMeasurement Power

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    0 32

    64

    96

    128

    160

    192

    224

    256

    288

    320

    352

    384

    416

    448

    480

    512

    544

    576

    608

    640

    672

    704

    736

    768

    800

    832

    864

    896

    928

    960

    992

    # of channels

    Thr

    oughputrateMSamples/sec

    High speed recording 204,800Hz Full Acoustic 51,200Hz Modal / Signature 6,400Hz SCL TP rate

    SC3-V12 M/S (copper) SC3-V12 M/S (fiber optic) SC3-SP92 M/S (copper) SC3-SP92 M/S (fiber optic)

    Support larger channel counts at higher sampling rates

    Higher throughput rate (14Msamples/sec) compared to SCIII platform (8Msamples/sec)

    No trade-off between channel count and frequency span

    No trade-off between frame count and throughput rate

    Prepared for higher throughput rate (26Msamples/sec)

    Full acoustics272ch @ 51.2kHz

    Prepared for 520ch

    Structural dynamics & Rotating machinery1000+ch @ 6.4kHz

    Increased

    Power

    large scale tests1000 ch

    200 chSSL array

    or ASQ

    68 chwind tunnel &shock testing

    Prepared fornew functions

  • 8/2/2019 Introducing DAQ

    5/16

    copyrightLMSInter

    national-2010

    5

    LMS SCADAS LabSuperior Data Quality

    0.00001-180

    0.00003-170

    0.0001-160

    0.0003-150

    0.0010-140

    0.0032-130

    0.0100-120

    0.0316-110

    0.1000-100

    0.3162-90

    1-80

    3-70

    10-60

    32-50

    100-40

    316-30

    1000-20

    3162-10

    100000

    mVMIC ICP [10 kHz]MIC [20 kHz]DC accel MEMS [100 Hz]DC accel cap [100 Hz]ICP accel[5 kHz]dB Strain gauge [100 Hz]

    0.00001-180

    0.00003-170

    0.0001-160

    0.0003-150

    0.0010-140

    0.0032-130

    0.0100-120

    0.0316-110

    0.1000-100

    0.3162-90

    1-80

    3-70

    10-60

    32-50

    100-40

    316-30

    1000-20

    3162-10

    100000

    mVMIC ICP [10 kHz]MIC [20 kHz]DC accel MEMS [100 Hz]DC accel cap [100 Hz]ICP accel[5 kHz]dB Strain gauge [100 Hz]

    Typical SNR for several sensors

    0.00 26000.00Hz

    -200.00

    0.00

    -100.00

    -150.00

    -50.00

    -190.00

    -180.00

    -170.00

    -160.00

    -140.00

    -130.00

    -120.00

    -110.00

    -90.00

    -80.00

    -70.00

    -60.00

    -40.00

    -30.00

    -20.00

    -10.00

    dBV

    150 dB Dynamic Range

    Typical harmonic distortion incompetitive systems

    24 bit A/D conversion

    150 dB Dynamic Range:

    Superior Data Quality

    No need for autoranging

    Best-in-class limitation of

    harmonic distortion

    Additional manual ranging

    Spurious free noise floor

    down to -180 dB forextreme conditions

    Best-in-class interchannel specs

    Phase matchbetter than 0.2 @ 10 kHz

    Crosstalk -123 dB @ 1 kHz

  • 8/2/2019 Introducing DAQ

    6/16

    copyrightLMSInter

    national-2010

    6

    SCM05

    Introducing Lab-Mobility

    SCM02

    Full M/S compatibility between anymember of the SCADAS Family

    SCADAS Mobile

    SCADAS Recorder SCADAS Lab

    Offering a higher degree offlexibility in the lab

    More efficient combination of Field

    and Laboratory measurements

    SCM09

    SCR07SCL

  • 8/2/2019 Introducing DAQ

    7/16

    copyrightLMSInter

    national-2010

    7

    Introducing Lab-Mobility

    Example 1 more effective combination of Field and Laboratory Testing

    M/S Connectivity

  • 8/2/2019 Introducing DAQ

    8/16

    copyrightLMSInter

    national-2010

    8

    Introducing Lab-Mobility

    Example 2 more flexibility in the laboratory

    Testrig 1 Testrig 2 Testrig 3

    M/S Connectivity

    Special conditioning like:

    Artificial head

    Strain

    CAN

  • 8/2/2019 Introducing DAQ

    9/16

    copyrightLMSInter

    national-2010

    9

    LMS SCADAS PlatformModular Signal Conditioning Concept

  • 8/2/2019 Introducing DAQ

    10/16

    copyrightLMSInternational-2010

    10

    LMS SCADAS FamilyInput Modules

    Eight channel Voltage / ICP / Bridge module (VB8)

    The VB8 is the most versatile of the LMS SCADAS Mobile modules, supporting:

    Voltage ICP / TEDS

    Microphones

    DC accelerometers (MEMS, piezoresistive)

    Support of 1/1, and bridge configuration, with symmetrical supply sensing

    Programmable bridge supply up to 10VDC Accurate bridge balancing through current injection

    120 and 350 bridge completion

    Internal shunt calibration, with a choice of four shunt resistor values

    Force & pressure transducers

    Potentiometers

    Support of differential and single-ended active sensors

    Versatility at its best

  • 8/2/2019 Introducing DAQ

    11/16

    copyrightLMSInternational-2010

    11

    LMS SCADAS FamilyInput Modules

    Four-channel Input Module for Rotational Vibration (RV4)

    4 x Analog Tacho input

    Differential analog tacho, pulse train TTL

    2V, 20V, 0 Hz to 40 kHz

    Up to 400 pulses/rev at 6000 rpm

    4 x Digital Tacho input

    TTL

    0 Hz to 200 kHz

    Up to 2000 pulses/rev at 6000 rpm

    2 x Incremental Encoder input

    RS485, supporting A, B and reference signals

    +5V sensor supply with sense

    0 Hz to 200 kHz

    Up to 2000 pulses/rev at 6000 rpm

    The complete rotating machinery solution

  • 8/2/2019 Introducing DAQ

    12/16

  • 8/2/2019 Introducing DAQ

    13/16

    copyrightLMSInternational-2010

    13

    LMS SCADAS FamilyInput Modules

    Dual channel CAN module (CN4)

    Four CAN channel inputs

    Each CAN channel can be individually configured for high-speed or low-speed CAN

    Software selectable list of CAN channels to be measured with thedynamic channels

    Eight-channel thermocouple module (T8)

    The accurate cold junction compensation and on-board linearization provide a highdegree of accuracy over the thermocouple measurement range.

    Standard miniature thermocouple connection

    Channel selectable thermocouple type

    Support for type B, E, J, K, N, R, S and T thermocouples

    Up to 200 Hz sample rate for fast-changing thermocouple signals

    Measure anything

  • 8/2/2019 Introducing DAQ

    14/16

    copyrightLMSInternational-2010

    14

    Continued SCIII Support

    SCIII frames can be purchased till end of 2011

    SCIII modules can be purchased till end of 2012

    Guaranteed support till end of 2018 (repairs/spare parts)

    After that best effort continued support (excellent track record with SCADAS I & II)

  • 8/2/2019 Introducing DAQ

    15/16

    copyrightLMSInternational-2010

    15

    SCL for Rotating machineryapplications

    2 x Tacho

    1 x IRIG-B

    1 x CAN

    Included in SCL20-SIG frame

    SCL for Structural Dynamicsapplications

    2 x DAC

    1 x IRIG-B

    Included in SCL20-STR frame

    Mainframe

    SCL for Vibration Controlapplications

    2 x DAC

    1 x STOP

    1 x IRIG-B

    Included in SCL20-ENV frame

    SCL20-SIG SCL20-ENVSCL20-STR

    SCL20-SIG + SCL-DAC4 allows combined rotating machinery & structural dynamic testing SCL20-STR + SCL-RV4 allows combined structural dynamic & rotating machinery & testing SCL20-ENV + SCL-DAC4 and/or SCL-RV4 allows combined Vibration control & rotating machinery/structural dynamic testing

  • 8/2/2019 Introducing DAQ

    16/16

    copyrightLMSInternational-2010

    16

    LMS SCADAS LabState-of-the-art Laboratory data acquisition system

    Unifying all data acquisition systems for Lab and Field Testing

    SCADASLab

    Measurement Power&

    Data Quality

    OptimizedInvestment

    &Reliability

    150 dB dynamic range to capture low & high level signals without auto-ranging

    14 MSamples/sec data transfer rate eliminating compromises between channel count vs. frequency span

    Ready to tackle new NVH challenges high-channel-array sound source localization, strain-based interface forces,hybrid and electrical vehicles,...

    Efficiency&

    Productivity

    High channel density per frame

    100% compatibility with currentinvestment on LMS Test.Lab

    Based on proven SCADAS Mobiletechnology

    embedding 30+ years of data

    acquisition hardware know-how

    Mobility & flexibility in the laboratoryenvironment through arbitrary mix &match between SCM/R/L frames

    single device measures everythingV, ICP, strain, CAN, IE, ...

    flexibility in connectivity: BNC,

    Sub-D, CAMAC

    textual channel status feedback ondigital display for fast set-up

    verification & correction