Intro to the DMC 300 | Electronic Dosimeter

20
Radiation Safety. Perfected.

description

A quick intro to the DMC 3000 Electronic Dosimeter.

Transcript of Intro to the DMC 300 | Electronic Dosimeter

Page 1: Intro to the DMC 300 | Electronic Dosimeter

Radiation Safety. Perfected.

Page 2: Intro to the DMC 300 | Electronic Dosimeter

DMC 3000Personal Electronic Dosimeter

Radiation. Safety.

Page 3: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

Page 4: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000| New Features and Improvements

New Features

Vibration Alarms

Pocket and Belt Clips

Military Grade EMI Immunity

Multiple LED Alarm

Indicators

Page 5: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | New Features and Improvements

ImprovementsLarger Display

Louder Speaker

Ultra Bright LED

Expanded Energy

Range

Uses a AAA Battery

9-11 Month Battery

Life

Page 6: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Overview

Display Features

- Large viewing angle

- 6-8 alpha-numeric digits

- 3 top mounted LED’s for alarms and dose increments

- Two push buttons for ease-of-use

Page 7: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Overview

Alarm Features

- Alarming speaker with level > 85 dB (A)

at 30cm, frequency < 4800 Hz

- Tactile alarm (vibrator)

- High efficiency red flash LED on front of device

- Dose and dose rate alarms

- Alarm on battery removal

Page 8: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Overview

Histogram Features

- Histogram is saved to non-volatile memory (EEPROM)

- Workers dose (1uSv/0.1 mrem)

- Stored in increments 10s, 1 min, 10 min, 1h, or 24h

- Event log marks events during the selected time period

- Stores data for several consecutive workers’ entries and exits

Page 9: Intro to the DMC 300 | Electronic Dosimeter

Energy Response: 15 keV to 7 MeV at better than +/- 20%

Accuracy: <+/- 10% for Cs137 @ 21mSv/h

<= +/- 15% for Am241 and X:16keV

Measurement Range: 0.1uSv/hr to 10 Sv/hr (0.01mrem/h - 1000R/h)

Dose Display: 1uSv/hr to 10Sv/hr (0.1mrem/h - 1000R/h)

Rate Display: 0.01mSv/h to 10 Sv/h (1mrem/h to 1000R/h)

Dose Rate Linearity: <-/+ 20% up to 10 Sv/h

(1000 rem/h) for Co-60 & X-Ray H30 20 keV

Pulsed Field Linearity: <-/+ 20% up to 6 Sv/h

(600 rem/h) for Pulsed X-Rays, 20msec pulse

width, 1, 10 & 20 pulses/sec

Saturation: Indication above 6 Sv/h (600 rem/h)

Units Displayed: mSv, uSv, mrem

Radiation. Safety.

The DMC 3000 | Overview

Measurement Characteristics

Page 10: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Overview

Energy Response

Page 11: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Overview

Dose Rate Linearity

Page 12: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Physical Features

85 dB Audible Speaker + Vibration

User Friendly Dual Push Buttons

Ultra Bright Alarm LED

Page 13: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Physical Features

Green or Blue Dose Increment Indicator

8 Digit Backlit LCD Display

Red Alarm Indicator

Page 14: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Physical Features

Optional Robust Belt Clip

Inexpensive AAA Battery

Up to 9 Months Battery Life

Page 15: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Accessories

Standard Clip Optional Belt Clip Front Pocket Clip

Page 16: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Accessories

Wall Mounted Wireless USB Reader Wireless Desktop USB Reader

Page 17: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Accessories

Transmits Real Time Data to Telemetry Receivers

Low-power Optimized for AAA Battery with Long Life

External Power Options and900 MHz or 2.4 GHz

Frequencies

Telemetry Module

Page 18: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Accessories

Upgrades to iDC Calibrator For DMC 3000

New Carriage for IRD Calibrator

Page 19: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

The DMC 3000 | Where to Buy

EuropeMirion Technologies (MGPI), S.A.Lieu-dit Cales, route d’Eyguieres,13113 Lamanon FranceT: +33 490 595959

AmericasMirion Technologies (MGPI), Inc.5000 Highlands Pkwy, Suite 150Smyrna GA, 30082USAT: +1 770 432 2744

Asia

Mirion Technologies ShanghaiRoom 801, 78 Jianchang San LuZhabei District, Shanghai 200436ChinaT: +86 21 6180 6920

Page 20: Intro to the DMC 300 | Electronic Dosimeter

Radiation. Safety.

Available July 2012

DMC 3000Personal Electronic Dosimeter