Features Used in tension controllers and tension meters. We offer a line of tension sensors whose rated tensions range from 100 N to 5000 N. Models MB06□S / MB12□S / MB26□S / MB34□S Intrinsically safe explosion-proof design (can be installed in hazardous locations where there is a risk of steam of flammable or explosive gas) CE mark (EU directive) certified MB tension sensors offer performance and reliability Can be used over a wide range of tensions, from low to high A wide angle of resultant tension force makes these sensors easy to install MB tension sensors are strain-gauge types with high sensitivity and good responsiveness Specifications Model Rated tension (N) Roller displacement (μm/N) Allowable roller weight (kg) Mass (kg) Tension force direction Ambient operating temperature: -10 to +50°C Power supply voltage: +6 VDC/20 mA MB06BS 100 2.42 10 1.5 Detection in the forward/reverse directions is possible MB06AS 200 1.20 20 MB12BS 100 2.80 10 0.8 MB12AS 200 1.38 20 MB26BS 500 0.47 50 3.4 MB26AS 1000 0.22 100 MB34BS 3000 0.086 300 16.1 MB34AS 5000 0.057 350 Providing safety and stability, even in an explosive environment The re-launch of the explosion proof MB Tension Sensor series Intrinsically Safe Explosion-Proof MB Tension Sensors MB12□S MB06□S MB34□S MB26□S External dimensions Wiring diagram Note 1. Roller displacement indicates the displacement of the roller per load of 1 N. Note 2. Allowable roller weight for rated tension indicates the permissible roller weight in double-sided detection. Note 3. If the MB06□S, MB12□S or MB26□S is supplied with a wall mounting bracket (optional), the suffix (-W) will be added to their model names. (Example: MB12BS-W) Only detection in the forward direction is possible. Detection in the reverse direction is not possible Sensor output signal DC power supply Class D grounding or greater Class D grounding or greater Connector connection MB tension sensor MB06(A・B)S、MB12(A・B)S MB26(A・B)S、MB34(A・B)S SHIELD SHIELD 1 2 3 4 WM0001240-01 Zener barrier Manufacturer's model : Z961(P&F) Connector connection Hazardous location Non-hazardous location Sensor output signal DC power supply Class A grounding Class D grounding or greater MB tension sensor MB06(A・B)S、MB12(A・B)S MB26(A・B)S、MB34(A・B)S 【Option ※ Inside the two-dot chain line】 Zener barrier box MK0001110-JA(For double-sided detection) MK0001210-JA(For single-sided detection) SIG COM COM +6V 4 3 2 1 1 8 7 2 3 6 5 4 +V(+4.6V) COM SIG COM COM SIG COM +V(+4.6V) 4 5 6 3 2 7 8 1 +6V COM COM SIG Note ・For single-sided detection, the tension sensor and zener barrier are a pair. Since the wiring does not change, perform wiring for one set. ・Explosion-proof symbol:Ex ia ⅡC T4 Ga ・Hazardous areas that can be used:zone 0、zone 1、 zone 2 ・Range of hazardous gas vapors that can be used:Equipment group ⅡC , Temperature class T4 ・Safety retention rating:Allowable voltage 8.7V , Allowable current 178mA , Allowable power 0.39W Internal inductance Ignore values , Internal capacitance 1.78μF , Operating temperature -10℃~+50℃ ・Application criteria:Factory electrical equipment explosion-proof guidelines (Internationally harmonized technical guidelines)JNIOSH-TR-46-1 and 6:2015 ・Do not apply shock or friction to the tension sensor as there is a risk of fire. ・Details are described in the instruction manual (QJ4156). Be sure to refer to the instruction manual before use. ・Please refer to the <Maintenance of Explosion Proof Electrical Equipment> for work. Zener barrier box Dwg. No.: RM0001510-EC Zener barrier box (for dual-sided detection) Dwg. No.: MK0001110-EA Intrinsically safe explosion-proof Zenner barrier Z961 (PEPPERL+FUCHS) Dwg. No.: WM0001240-01E Name : Intrinsically safe explosion-proof Zener barrier (TIIS compliant products) Type : Z961 Manufacturer : PEPPERL+FUCHS Specifications : [EEX ia] IIC Um=AC250V 50/60Hz , DC250V Ambient temperature 60℃ Safety holding rating : Intrinsically safe circuit maximum voltage 8.7V Intrinsically safe circuit maximum current 178mA Intrinsically safe circuit maximum power 0.39W Intrinsically safe circuit allowable inductance 1.14mH Intrinsically safe circuit allowable capacitance 4.9μF Notes ※1. Terminals for use with Class-A grounding are electrically connected to the DIN rail mounting brackets. Be careful when installing these terminals. ※2. For usage details, be sure to refer to the manufacturer's instruction manual. ※1 Terminals for use with Class-A grounding DIN rail mounting (35-mm width) Intrinsically safe circuit side (non-safe side) Terminal number :1,2,3,4 Non-intrinsically safe circuit side (safe side) Terminal number :5,6,7,8 Terminals for use with Class-A grounding ※1 115 92.5 13 109.5 115.7 Terminal on the safe location side Terminal on the hazardous location side Manufacturer's model :Z961(P&F) M4×6L SW/W for earth (Class D or above) M4×6L SW/W 2 Mounting holes MODEL NO. SERIAL NO. ※3 ※3 Zener barrier (WM0001240-01) Class A ※4 Hole for cable 8-φ16 (Internal diameter of cable bush φ11) (Internal) ※5 1 for earth (Class D or above) ※1 Mount using 4 x 7-mm mounting holes. ※2 Use when using the optional mounting bracket. ※3 Ensure that the earthing is Class D or above (Grounding resistance = 100 Ω or less) ※4 Ensure that the earthing is Class A (Grounding resistance = 10 Ω or less) ※5 The orientation of the Zener barrier can be changed, depending on the way the equipment is installed. For details about the Zener barrier, please refer to the Zener barrier manufacturer's instruction manual. 120 150 140 32 32 15 32 32 15 138 (167) (150) (25) (25) (100) (15) (15) 90 (15) (15) 120 (40) (40) 40 (40) (40) 70 (5) (12) 150 (15) (15) 120 4-φ5 4-φ7 4-φ7 QI1200.0-E 2010TP Printed in Japan Hachioji Office 2951-4 Ishikawa-machi, Hachioji, Tokyo, 192-8522, Japan Telephone: +81-42-660-7409 Facsimile: +81-42-645-7737 Website: http://www.nireco.com E-mail: [email protected] NIRECO and the NIRECO logo are trademarks or registered trademarks of Nireco Corporation in Japan. The details contained in this catalog are subject to change without notice. Please contact us at the following address when considering a purchase. NIRECO CORPORATION

Transcript of Intrinsically Safe Explosion-Proof MB Tension Sensors ModelsOK OK NG 143 2 (500) 53 66.9 15 43.25...

Page 1: Intrinsically Safe Explosion-Proof MB Tension Sensors ModelsOK OK NG 143 2 (500) 53 66.9 15 43.25 130 11 18 4 8 10 ≧ 60 (21) 16 62.5 62.5 6.5 72 58 6.5 6.5 40 4-φ7 OK OK NG cable

Features

Used in tension controllers and tension meters.We offer a line of tension sensors whose rated tensions range from 100 N to 5000 N.

Models

MB06□S / MB12□S /

MB26□S / MB34□S

● Intrinsically safe explosion-proof design (can be installed in hazardous locations where there is a risk of steam of flammable or explosive gas)

● CE mark (EU directive) certified● MB tension sensors offer performance and reliability● Can be used over a wide range of tensions, from low to high● A wide angle of resultant tension force makes these sensors easy to install● MB tension sensors are strain-gauge types with high sensitivity and good responsiveness

Specifications

Model

Rated tension (N)

Roller displacement (μm/N)

Allowable roller weight (kg)

Mass (kg)

Tension force direction

Ambient operating temperature: -10 to +50°CPower supply voltage: +6 VDC/20 mA

MB06BS

100

2.42

10

1.5

Detection in the forward/reverse directions is possible

MB06AS

200

1.20

20

MB12BS

100

2.80

10

0.8

MB12AS

200

1.38

20

MB26BS

500

0.47

50

3.4

MB26AS

1000

0.22

100

MB34BS

3000

0.086

300

16.1

MB34AS

5000

0.057

350

Providing safety and stability, even in an explosive environment

Th

e re

-lau

nc

h o

f the

ex

plo

sio

n p

roo

f MB

Te

ns

ion

Se

ns

or s

erie

s

Intrinsically Safe Explosion-ProofMB Tension Sensors

MB12□SMB06□S

MB34□SMB26□S

External dimensions

Wiring diagram

Note 1. Roller displacement indicates the displacement of the roller per load of 1 N.Note 2. Allowable roller weight for rated tension indicates the permissible roller weight in double-sided detection.Note 3. If the MB06□S, MB12□S or MB26□S is supplied with a wall mounting bracket (optional),

the suffix (-W) will be added to their model names. (Example: MB12BS-W)

Only detection in the forward direction is possible. Detection in the reverse direction is not possible

Sensor output signal

DC power supply

Class D grounding or greaterClass D grounding or greater

Connector connectionMB tension sensorMB06(A・B)S、MB12(A・B)SMB26(A・B)S、MB34(A・B)S

SHIELD

SHIELD

1

2

3

4

WM0001240-01

Zener barrierManufacturer's model : Z961(P&F)

Connector connection

Hazardous location Non-hazardous location

Sensor output signal

DC power supply

Class A grounding

Class D grounding or greater

MB tension sensorMB06(A・B)S、MB12(A・B)SMB26(A・B)S、MB34(A・B)S

【Option ※ Inside the two-dot chain line】Zener barrier boxMK0001110-JA(For double-sided detection)MK0001210-JA(For single-sided detection)

SIGCOM

COM

+6V

4

3

2

1 1 8

72

3 6

54

+V(+4.6V)

COM

SIG

COM

COM

SIG

COM

+V(+4.6V)

4 5

63

2 7

81 +6V

COM

COMSIG

Note・For single-sided detection, the tension sensor and zener barrier are a pair. Since the wiring does not change, perform wiring for one set.・Explosion-proof symbol : Ex ia ⅡC T4 Ga・Hazardous areas that can be used : zone 0、zone 1、zone 2・Range of hazardous gas vapors that can be used : Equipment group ⅡC , Temperature class T4・Safety retention rating : Allowable voltage 8.7V , Allowable current 178mA , Allowable power 0.39W

Internal inductance Ignore values , Internal capacitance 1.78μF ,Operating temperature -10℃~+50℃

・Application criteria : Factory electrical equipment explosion-proof guidelines(Internationally harmonized technical guidelines)JNIOSH-TR-46-1 and 6:2015

・Do not apply shock or friction to the tension sensor as there is a risk of fire.・Details are described in the instruction manual (QJ4156). Be sure to refer to the instruction manual before use.・Please refer to the <Maintenance of Explosion ProofElectrical Equipment> for work.

Zener barrier boxDwg. No.: RM0001510-EC

Zener barrier box (for dual-sided detection)Dwg. No.: MK0001110-EA

Intrinsically safe explosion-proof Zenner barrier Z961 (PEPPERL+FUCHS)Dwg. No.: WM0001240-01E

Name : Intrinsically safe explosion-proof Zener barrier (TIIS compliant products)Type : Z961Manufacturer : PEPPERL+FUCHSSpecifications : [EEX ia] IIC

Um=AC250V 50/60Hz , DC250VAmbient temperature 60℃

Safety holding rating :Intrinsically safe circuit maximum voltage 8.7VIntrinsically safe circuit maximum current 178mAIntrinsically safe circuit maximum power 0.39WIntrinsically safe circuit allowable inductance 1.14mHIntrinsically safe circuit allowable capacitance 4.9μF

Notes※1. Terminals for use with Class-A grounding are electrically connected to

the DIN rail mounting brackets. Be careful when installing these terminals.※2. For usage details, be sure to refer to the manufacturer's instruction manual.

※1Terminals for use with Class-A grounding

DIN rail mounting (35-mm width)

Intrinsically safe circuit side (non-safe side)Terminal number:1,2,3,4

Non-intrinsically safe circuit side (safe side)Terminal number:5,6,7,8

Terminals for use with Class-A grounding

※1

115

92.5 13

109.5

115.7

Terminal on the safe location sideTerminal on the hazardous location side

Manufacturer's model:Z961(P&F)

M4×6L SW/W

for earth(Class D or above)

M4×6L SW/W

※2

Mounting holes

MODEL NO.SERIAL NO.

※3

※3

Zener barrier(WM0001240-01) Class A※4

Hole for cable 8-φ16(Internal diameter of cable bush φ11)

(Internal)

※5

※1

for earth(Class D or above)

※1 Mount using 4 x 7-mm mounting holes.※2 Use when using the optional mounting bracket.※3 Ensure that the earthing is Class D or above (Grounding resistance = 100 Ω or less)※4 Ensure that the earthing is Class A (Grounding resistance = 10 Ω or less)※5 The orientation of the Zener barrier can be changed, depending on the way

the equipment is installed.For details about the Zener barrier, please refer to the Zener barriermanufacturer's instruction manual.

120

150

140

32

32

15

32

32

15

138

(167)

(150)

(25) (25)(100)

(15)

(15)

90

(15) (15)120

(40)

(40)

40

(40) (40)70

(5) (12)150

(15)

(15)

120

4-φ54-φ7

4-φ7

QI1200.0-E 2010TP Printed in Japan

Hachioji Office2951-4 Ishikawa-machi, Hachioji, Tokyo, 192-8522, JapanTelephone: +81-42-660-7409 Facsimile: +81-42-645-7737

Website: http://www.nireco.com E-mail: [email protected]

NIRECO and the NIRECO logo are trademarks or registered trademarks of Nireco Corporation in Japan.The details contained in this catalog are subject to change without notice. Please contact us at the following address when considering a purchase.

NIRECO CORPORATION

Page 2: Intrinsically Safe Explosion-Proof MB Tension Sensors ModelsOK OK NG 143 2 (500) 53 66.9 15 43.25 130 11 18 4 8 10 ≧ 60 (21) 16 62.5 62.5 6.5 72 58 6.5 6.5 40 4-φ7 OK OK NG cable

External dimensions

Intrinsically safe explosion-proof MB tension sensorsMB06AS Dwg. No.: MD0004860-EAMB06BS Dwg. No.: MD0004870-EA

Intrinsically safe explosion-proof MB tension sensorsMB12AS Dwg. No.: MD0004880-EAMB12BS Dwg. No.: MD0004890-EA

Intrinsically safe explosion-proof MB tension sensorsMB26AS Dwg. No.: MD0004900-EAMB26BS Dwg. No.: MD0004910-EA

Intrinsically safe explosion-proof MB tension sensorsMB34AS Dwg. No.: MD0004920-EAMB34BS Dwg. No.: MD0004930-EA

※1

1234

+6VDCCOMSIGCOM

COMSIGCOM+6VDC

4321

Horizontal

fulcrum

NoteSelect the cable so that the total lengthfrom the sensor to the controller ormeter is 50m or less through the zenerbarrier.

※1The cable between the sensor and the Zener barrierA) Use the supplied connector and crimp terminal.B) Use a 4-core shielded cable of AWG22 or higherand connect the connector referring to the figurebelow.

C) Be sure to connect the shielded wire tothe connector body.

D) The internal inductance of the sensoris negligible.The internal capacitance is 1.78μF.Select the Zener barrier within the above values.

E) Refer to the instruction manual for details.

connector

Connector body (metal)

Shield(Class A grounding)

ApplicationconnectorPin number

Accessories for the cables between the sensor and the Zener barrier・connector・Crimp terminal (bar x 4, circle x 1)・Conductive tape 6×15mm

・Explosion-proof symbol : Ex ia ⅡC T4 Ga・Hazardous areas that can be used : zone 0、zone 1、zone 2・Range of hazardous gas vapors that can be used : Equipment group ⅡC , Temperature class T4・Safety retention rating : Allowable voltage 8.7V , Allowable current 178mA , Allowable power 0.39W

Internal inductance Ignore values , Internal capacitance 1.78μF ,Operating temperature -10℃~+50℃

・Application criteria : Factory electrical equipment explosion-proof guidelines(Internationally harmonized technical guidelines)JNIOSH-TR-46-1 and 6:2015

・Do not apply shock or friction to the tension sensor as there is a risk of fire.・Details are described in the instruction manual (QJ4156). Be sure to refer to the instruction manual before use.・Please refer to the <Maintenance of Explosion ProofElectrical Equipment> for work.

Intrinsically safeequipment identification (blue)

Pan-head screwM4×5LFor groundingRound bare crimp terminal(included)

SpecificationsRated tension: A:5000N B:3000N(when both sides are detected)Roll allowable mass: A:350kg B:300kg (when both sides are detected)Operating temperature range: -10 ℃ ~ + 50 ℃Weight: 16.1 kgDetection range:The resultant direction of tension isthe hatched area in the figure below.

roll

cableSensor

The sensor mounting direction should bethe same with respect to the cable side.

The installation surface must be flat.(Flatness 0.05 or less)Clean the installation surface cleanlyon both the sensor and machine sides.

The signal polarity for forward and reverseloads is switched on the controller ormeter side.

Certification mark

Explosion-proof display

NoteRefer to the for precautions regarding installation.

Roll center

fulcrum

Sensor cable

OK NGOK

35

39

20

(500)

103

280

115

118

≧ 60

1414

90

11.5 11.5257

128.5 128.5

2520

2525 230

98

4-φ14

Leave a space of 60mm or more onthe cable side.

Horizontal

fulcrum

NoteSelect the cable so that the total lengthfrom the sensor to the controller ormeter is 50m or less through the zener barrier.

※1The cable between the sensor and the Zener barrierA) Use the supplied connector and crimp terminal.B) Use a 4-core shielded cable of AWG22 or higher and connect the connector referring to the figure below.

C) Be sure to connect the shielded wire to the connector body.D) The internal inductance of the sensor is negligible.The internal capacitance is 1.78μF.Select the Zener barrier within the above values.

E) Refer to the instruction manual for details.

connector1234

Connector body (metal)

+6VDCCOMSIGCOMShield(Class A grounding)

COMSIGCOM+6VDC

4321

ApplicationconnectorPin number

Accessories for the cables between the sensor and the Zener barrier・connector・Crimp terminal (bar x 4, circle x 1)・Conductive tape 6×15mm

※1

・Explosion-proof symbol : Ex ia ⅡC T4 Ga・Hazardous areas that can be used : zone 0、zone 1、zone 2・Range of hazardous gas vapors that can be used : Equipment group ⅡC , Temperature class T4・Safety retention rating : Allowable voltage 8.7V , Allowable current 178mA , Allowable power 0.39W

Internal inductance Ignore values , Internal capacitance 1.78μF ,Operating temperature -10℃~+50℃

・Application criteria : Factory electrical equipment explosion-proof guidelines(Internationally harmonized technical guidelines)JNIOSH-TR-46-1 and 6:2015

・Do not apply shock or friction to the tension sensor as there is a risk of fire.・Details are described in the instruction manual (QJ4156). Be sure to refer to the instruction manual before use.・Please refer to the <Maintenance of Explosion Proof Electrical Equipment> for work.

Intrinsically safeequipment identification (blue)

Pan-head screwM4×5LFor groundingRound bare crimp terminal(included)

SpecificationsRated tension: A:200N B:100N(when both sides are detected)Roll allowable mass: A:20kg B:10kg(when both sides are detected)Operating temperature range: -10 ℃ ~ + 50 ℃Weight: 0.8 kgDetection range:The resultant direction of tension isthe hatched area in the figure below.

roll

cable

Sensor

The sensor mounting direction should bethe same with respect to the cable side.

The installation surface must be flat.(Flatness 0.05 or less)Clean the installation surface cleanlyon both the sensor and machine sides.Leave a space of 60mm or more onthe cable side.

The signal polarity for forward and reverseloads is switched on the controller ormeter side.

Certification mark

Explosion-proof display

NoteRefer to the for precautions regarding installation.

Roll centerfulcrum

Sensor cable

OK OK NG

143

2

(500) 53

66.9

15

43.25

130

11

18

48

10

≧ 60

(21)

62.516 62.5

6.5 6.5

5872

6.5

6.5

40

4-φ7

NGOKOK

cableSensor

fulcrum Roll center

NoteRefer to the for precautions regarding installation.

Explosion-proof display

Certification mark

The signal polarity for forward and reverseloads is switched on the controller ormeter side.

Leave a space of 60mm or more onthe cable side.

The installation surface must be flat.(Flatness 0.05 or less)Clean the installation surface cleanlyon both the sensor and machine sides.

The sensor mounting direction should bethe same with respect to the cable side.Sensor

cable

roll

SpecificationsRated tension: A:200N B:100N (when both sides are detected)Roll allowable mass: A:20kg B:10kg (when both sides are detected)Operating temperature range: -10 ℃ ~ + 50 ℃Weight: 1.5 kgDetection range:The resultant direction of tension isthe hatched area in the figure below.

For groundingRound bare crimp terminal (included)

Pan-head screwM4×5L

Intrinsically safeequipment identification (blue)

・Explosion-proof symbol : Ex ia ⅡC T4 Ga・Hazardous areas that can be used : zone 0、zone 1、zone 2・Range of hazardous gas vapors that can be used : Equipment group ⅡC , Temperature class T4・Safety retention rating : Allowable voltage 8.7V , Allowable current 178mA , Allowable power 0.39W

Internal inductance Ignore values , Internal capacitance 1.78μF ,Operating temperature -10℃~+50℃

・Application criteria : Factory electrical equipment explosion-proof guidelines(Internationally harmonized technical guidelines)JNIOSH-TR-46-1 and 6:2015

・Do not apply shock or friction to the tension sensor as there is a risk of fire.・Details are described in the instruction manual (QJ4156). Be sure to refer to the instruction manual before use.・Please refer to the <Maintenance of Explosion Proof Electrical Equipment> for work.

※1Accessories for the cables between the sensor and the Zener barrier・connector・Crimp terminal (bar x 4, circle x 1)・Conductive tape 6×15mm

connectorPin number Application

1234

+6VDCCOMSIGCOM

Same on the back

Shield(Class A grounding)

COMSIGCOM+6VDC

Connector body (metal)

4321

connector

※1The cable between the sensor and the Zener barrierA) Use the supplied connector and crimp terminal.B) Use a 4-core shielded cable of AWG22 or higher andconnect the connector referring to the figure below.

C) Be sure to connect the shielded wire to the connector body.D) The internal inductance of the sensor is negligible.The internal capacitance is 1.78μF.Select the Zener barrier within the above values.

E) Refer to the instruction manual for details.

NoteSelect the cable so that the total lengthfrom the sensor to the controller ormeter is 50m or less through the zener barrier.

fulcrum

Horizontal

38.25

15

57

22 53

32

(500)

59

(5.2)

≧ 6044

60

60 17.5

4

17.5

99

95

47.5 47.5

525

445

5-M5×9L

4-M5×9L

1234

+6VDCCOMSIGCOM

COMSIGCOM+6VDC

4321

Horizontalfulcrum

NoteSelect the cable so that the total lengthfrom the sensor to the controller ormeter is 50m or less through the zener barrier.

※1The cable between the sensor and the Zener barrierA) Use the supplied connector and crimp terminal.B) Use a 4-core shielded cable of AWG22 or higher andconnect the connector referring to the figure below.

C) Be sure to connect the shielded wire to the connector body.D) The internal inductance of the sensor is negligible.The internal capacitance is 1.78μF.Select the Zener barrier within the above values.

E) Refer to the instruction manual for details.

connector

Connector body (metal)

Shield(Class A grounding)

ApplicationconnectorPin number

Accessories for the cables between the sensor and the Zener barrier・connector・Crimp terminal (bar x 4, circle x 1)・Conductive tape 6×15mm

※1

・Explosion-proof symbol : Ex ia ⅡC T4 Ga・Hazardous areas that can be used : zone 0、zone 1、zone 2・Range of hazardous gas vapors that can be used : Equipment group ⅡC , Temperature class T4・Safety retention rating : Allowable voltage 8.7V , Allowable current 178mA , Allowable power 0.39W

Internal inductance Ignore values , Internal capacitance 1.78μF ,Operating temperature -10℃~+50℃

・Application criteria : Factory electrical equipment explosion-proof guidelines(Internationally harmonized technical guidelines)JNIOSH-TR-46-1 and 6:2015

・Do not apply shock or friction to the tension sensor as there is a risk of fire.・Details are described in the instruction manual (QJ4156). Be sure to refer to the instruction manual before use.・Please refer to the <Maintenance of Explosion Proof Electrical Equipment> for work.

Intrinsically safeequipment identification (blue)

Pan-head screwM4×5LFor groundingRound bare crimp terminal(included)

SpecificationsRated tension: A:1000N B:500N (when both sides are detected)Roll allowable mass: A:100kg B:50kg (when both sides are detected)Operating temperature range: -10 ℃ ~ + 50 ℃Weight: 3.4 kgDetection range:The resultant direction of tension isthe hatched area in the figure below.

roll

cable

Sensor

The sensor mounting direction should bethe same with respect to the cable side.

The installation surface must be flat.(Flatness 0.05 or less)Clean the installation surface cleanlyon both the sensor and machine sides.

The signal polarity for forward and reverseloads is switched on the controller ormeter side.

Certification markExplosion-proof display

NoteRefer to the for precautions regarding installation.

Roll center

fulcrum

Sensorcable

OK NGOK

(500) 68

56

74

180

20

≧ 60

22

30

12

77

54

9 9162

1613

3213

18 12150

75 75

84 78

610

4-φ9

Leave a space of 60mm or more onthe cable side.