Facultatea de Inginerie Electrică, Energetică si Informatică Aplicată
Intrerupatoare automate de joasa tensiune
Stundent: Cracană Cornel Colonescu Alexandru
Grupa: 6502
![Page 2: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/2.jpg)
Ce sunt întrerupatoarele automate?
2
![Page 3: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/3.jpg)
Clasificarea întrerupatoarelor automate de joasa tensiune
Dupa funcţiile de protecţie, care determină declansările automate:
– intreruratoare automate de curent maxim;– intrerupatoare automate de curent minim;– intrerupatoare automate de curent invers;– intrerupatoare automate de tensiune minima;– intrerupatoare automate de tensiune maxima;
![Page 4: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/4.jpg)
Dupa numarul polilor, intrerupatoarele automate pot fi:
– monopolare, – bipolare, – tripolare – tetrapolare.
Dupa felul curentului comutat:
– intrerupatoare de c.c. – intrerupatoare de c.a. monofazate, – intrerupatoare trifazate.
Dupa mediul de stingere a arcului pot fi: – in ulei, – in aer.
![Page 5: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/5.jpg)
Intrerupatoarele automate de c.a.
Se realizeaza in doua forme constructive:
intrerupatoare automate universale (in constructie deschisa).
Fig 1. Intrerupatoare automate universale
![Page 6: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/6.jpg)
intrerupatoare automate de tip compact (in constructie capsulata).
Figura 2. Intrerupator automat capsulat AMRO 200
Tensiunea nominala: 500 Vca, curentul nominal: 200 A, curentul de reglajal releelor Ir: 200 A curentul de declansare declansatorului de protectie (0,65-1,1)Ir. temperatura ambianta de functionare: -40.....+55 grade Celsius
![Page 7: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/7.jpg)
Intrerupatorul automat capsulat de tip USOL
1-maneta de actionare2-clichetul principal3-clapeta de armare4, 5-biele6-echipajul mobil7-contactul mobil8-contactul fix9-resort principal10-clapeta ax declansator11-declansator termic12-buton de reglaj13-armatura fixa
Figura 3. Sectiune prin intrerupatorul automat capsulat de tip USOL
![Page 8: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/8.jpg)
14-axul suport al echipajului mobil15-carcasa aparatului16-placa de prindere17-borne de racordare18-camera de stingere cu placi feromagnetice19-armatura mobila20-axul declansatorului,21-clichet auxiliar
Figura 3. Sectiune prin intrerupatorul automat capsulat de tip USOL
![Page 9: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/9.jpg)
![Page 10: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/10.jpg)
Date catalog :
![Page 11: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/11.jpg)
![Page 12: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/12.jpg)
![Page 13: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/13.jpg)
Intrerupatorul automat de tip oromax
Figura 4 . Intrerupator automat tip OROMAX
![Page 14: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/14.jpg)
l-contactul principal 2 -contactul de rupere (de arc)3a si 3b- rampele (coarnele)4- separator de flama5- piesa suport pentru elementele mobile de contact6- resort antagonist7- piesa intermediara;8- legatura flexibila9- calea de curent
Figura 5. Caile de curent ale unui intrerupator de tip OROMAX
![Page 15: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/15.jpg)
Figura 6. Caracteristica de protectie a unui intrerupator
Portiunea 1- caracteristica dependenta corespunzatoare declasatoarelor temobimetalice
Portiunea 2 - reprezinta caracteristica independenta corespunzatoare declasatoarelor electromagnetice
Portiunea 3 - corespunde zonei de protectie a sigurantelor fuzibile in cazul curentilor de scurt circuit
Portiunea 4- reprezinta curba de stabilitate termica a Instalatiei protejate
![Page 16: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/16.jpg)
Intrerupatoarele automate de c.c.
Intrerupatoare automate
de c.c
In constructie normala
Intrerupatoare ultrarapide
Intrerupatoare ultrarapide
electromagnetice
Intrerupatoare ultrarapide
electrodinamice
![Page 17: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/17.jpg)
Intrerupatoarele ultrarapide electromagnetice
Figura 7. Intrerupator automat de c.c. ultrarapid electromagnetic.
1-contactul fix,2-contactul mobil principal, 3-contactul de arc, 4- B-bobina de suflaj, 5- R-rezistenta pentru limitarea supratensiunilor pe contactea- ER-electromagnetul de retinere (zavorul), b- ED-electromagnetul de declansare
![Page 18: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/18.jpg)
Intrerupatoarele ultrarapide electrodinamice
Figura 12. Intrerupator automat de c.c. ultrarapid electrodinamic.
1, 2 - contactele principale3- tija mobila4- bobina declansatorului electrodinamic5-disc nemagnetic6- resort; 7 –declansator electromagnetic8-declansator electrodinamic; 9- clichet; 10- resort antagonist.
![Page 19: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/19.jpg)
1. http://www.rasfoiesc.com/inginerie/electronica/INTRERUPATOARE-AUTOMATE-DE-JOA28.php
2. http://www.etigroup.ro/catalog-pdf/industrie-si-spatii-rezidentiale/etibreak-intrerupatoare-automate-si-separatori-de-comutatie-de-joasa-tensiune
3. http://www.creeaza.com/tehnologie/electronica-electricitate/Intreruptoare-automate-de-joas679.php
4. http://www.etigroup.ro/catalog-pdf/industrie-si-spatii-rezidentiale/etibreak-intrerupatoare-automate-si-separatori-de-comutatie-de-joasa-tensiune
Bibliografie:
![Page 20: Intrerupatoare](https://reader033.fdocuments.net/reader033/viewer/2022051518/5695d3b91a28ab9b029ef068/html5/thumbnails/20.jpg)
20