Intraday Variability of Control in Intermittent Exotropia

14
Commercial relationships: None Intraday Variability of Control in Intermittent Exotropia Sarah R. Hatt, Brian G. Mohney, David A. Leske, Jonathan M. Holmes Mayo Clinic, Rochester, MN, USA

description

Intraday Variability of Control in Intermittent Exotropia. Sarah R. Hatt, Brian G. Mohney, David A. Leske, Jonathan M. Holmes Mayo Clinic, Rochester, MN, USA. Commercial relationships: None. Poor control: > 50% of waking hours Deterioration – consecutive visits: indicator for surgery - PowerPoint PPT Presentation

Transcript of Intraday Variability of Control in Intermittent Exotropia

Page 1: Intraday Variability of Control in Intermittent Exotropia

Commercial relationships: None

Intraday Variability of Control in Intermittent Exotropia

Sarah R. Hatt, Brian G. Mohney, David A. Leske, Jonathan M.

Holmes

Mayo Clinic, Rochester, MN, USA

Page 2: Intraday Variability of Control in Intermittent Exotropia

Intermittent Exotropia - Control• Poor control:

> 50% of waking hours

• Deterioration – consecutive visits: indicator for surgery

• Type and degree of variability of control within 1 day is not known

Implications for: • defining severity• interpreting change in control over time

Page 3: Intraday Variability of Control in Intermittent Exotropia

Purpose

To assess the variability of control over one day

in children with intermittent exotropia

using control scale to quantify control

Page 4: Intraday Variability of Control in Intermittent Exotropia

Methods – Control AssessmentControl Score Control Score Description

5 Constant exotropia during a 30-second observation period (before dissociation)

4 Exotropia >50% of the time during a 30-second observation period (before dissociation)

3 Exotropia <50% of the time during a 30-second observation period (before dissociation)

2 No exotropia unless dissociated (10 seconds): recovery in > 5 seconds

1 No exotropia unless dissociated (10 seconds): recovery in 1-5 seconds

0 Pure phoria: < 1 second recovery after 10-second dissociation

Mohney BG, Holmes JM. An office-based scale for assessing control in intermittent exotropia. Strabismus 2006;14:147-50.

Page 5: Intraday Variability of Control in Intermittent Exotropia

Control scale reliability near control k=0.95 distance control k=0.94

Inve

stig

ato

r 2

Investigator 1

0

1

2

3

4

5

0 1 2 3 4 5In

vest

iga

tor

2Investigator 1

0

1

2

3

4

5

0 1 2 3 4 5

Scores differed by no more than one level on the control scale:

Real change in control defined as change of 2 or more levels on scale.

Page 6: Intraday Variability of Control in Intermittent Exotropia

Methods – Intraday variability

• 13 children with intermittent exotropia (median age 8 years; range 1 to 13) No convergence insufficiency type exotropia

• No co-existing ocular pathology

• No amblyopia

Page 7: Intraday Variability of Control in Intermittent Exotropia

Methods – Intraday variability

Examined 3 or 4 times over one day

(minimum 2 hours apart)

Control assessed using control scale

Variable = change in control 2 or more levels on control scale over day (distance or near)

Stable = no change in control over day

10:31-13:008:00 -10:30 13:01-15:30 15:31-18:00

Page 8: Intraday Variability of Control in Intermittent Exotropia

Results – Intraday variability of control

Median angle - near

30^26^Median angle - distance

11Median control - near

20^25^

1*2.75Median control - distance

7.2 years7.3 yearsMean age

Stable control

7/13 (54%)

Variable control

6/13 (46%)N=13

* p=0.04

Page 9: Intraday Variability of Control in Intermittent Exotropia

Patient 1

Patient 10

Patient 13

Results – Variable distance control

Assessment time

Con

trol

sca

le r

atin

g

0

1

2

3

4

5

8:00 -10:30 10:31-13:00 13:01-15:30 15:31-18:00

Tro

pic

Ph

oric

Page 10: Intraday Variability of Control in Intermittent Exotropia

0

1

2

3

4

5

8:00 -10:30 10:31-13:00 13:01-15:30 15:31-18:00

Patient 3

Patient 5

Patient 11

Patient 13

Results – Variable near control

Assessment time

Con

trol

sca

le r

atin

g

Ph

oric

Tro

pic

Page 11: Intraday Variability of Control in Intermittent Exotropia

Results – Summary

• Control varies over one day in some patients with intermittent exotropia.

• Change occurs between spontaneous tropia and well controlled phoria.

• Worst control not always at the end of the clinical day.

Page 12: Intraday Variability of Control in Intermittent Exotropia

Change in distance control

0

1

2

3

4

5

January April August

Assessment time

Con

trol

sca

le r

atin

g

Tro

pic

Ph

oric

10:30

12:45 14:49

Page 13: Intraday Variability of Control in Intermittent Exotropia

Conclusions• An isolated measure of control may be insufficient

to represent: baseline severity change over time.

• If control has a role in evaluating severity, multiple measures will be needed.

• Change in isolated measures of control should not be used for surgical decision making.

Page 14: Intraday Variability of Control in Intermittent Exotropia

Thank You

Supported by:

EY015799 (JMH)

Research to Prevent Blindness, Inc.