Intra Frequency Cell Reselection
Click here to load reader
-
Upload
tariq-muhammad -
Category
Documents
-
view
68 -
download
2
description
Transcript of Intra Frequency Cell Reselection
Intra-frequency Cell Reselection Parameters
Specification
Prepared by:
ETISALAT MS section
HUAWEI Radio Network Planning Department
HUAWEIHUAWEI
Intra-frequency Cell Reselection Parameters Specification
2004-05-07
CONTENT
1. Intra-frequency cell reselection parameters specification.......................................................3
Huawei Confidential 2 of 5
Intra-frequency Cell Reselection Parameters Specification
1. Intra-frequency cell reselection parameters specification
Parameters Value Meaning
Qoffset2sn 0 0dB
Min RX level -58 -115dBm
Hysteresis2 2 4dB
Intra-frequency cell reselection threshold 6 12dB
Reselection delay time 1 1S
Min quality level -18 -18dB
Step 1: UMTS serving cell measurement Ec/Io < Intra-frequency cell reselection threshold + Min
quality level
Step 2: UMTS neighbor cell measurement RSCP > Min RX level and
UMTS neighbor cell measurement Ec/Io > Min quality level
Step 3: UMTS neighbor cell measurement Ec/Io – Qoffset2sn > UMTS serving cell measurement
Ec/Io + Hysteresis2
Step 4: Reselection delay time
Step 5: Trigger UMTS serving cell to UMTS neighbor cell reselection
Parameters specification:
Step1: UMTS serving cell measurement Ec/Io < Intra-frequency cell reselection threshold + Min
quality level
UMTS serving cell measurement Ec/Io: the measurement Ec/Io value in UMTS serving cell.
Intra-frequency cell reselection threshold: Threshold for intra-frequency cell reselection. When the
quality (CPICH Ec/Io measured by UE) of the serving cell is lower than the threshold plus Min
quality level of the cell, the intra-frequency cell reselection procedure will be started.
Value range: -16 ~ 10.
Physical value range: -32 ~ 20; step: 2.
Physical unit: dB.
Min quality level: Minimum required quality level corresponding to the CPICH Ec/Io. UE
can camp on the cell only when the CPICH Ec/Io measured is larger than the value of this
Huawei Confidential 3 of 5
Intra-frequency Cell Reselection Parameters Specification
parameter; it will affect the call setup success rate.
Value range: -24 ~ 0.
Physical unit: dB.
Step 2: UMTS neighbor cell measurement RSCP > Min RX level and
UMTS neighbor cell measurement Ec/Io > Min quality level
Min RX level: Minimum required Rxlev value of the UMTS FDD neighboring cell.
Value range: -58 ~ -13.
Physical value range: -115 ~ -25; (-58:-115; -57:-113; ..., - 13 : 25 ).
Physical unit: dBm.
Step 3: UMTS neighbor cell measurement Ec/Io – Qoffset2sn > UMTS serving cell measurement
Ec/Io + Hysteresis2
Qoffset2sn: Cell offset used for CPICH Ec/No during cell reselection. It can be used to change the
cell edge. The greater this parameter is set, the smaller the probability of selecting the neighboring
cell.
Value range: -50~50.
Physical unit: dB.
Hysteresis 2: The hysteresis for UMTS serving cell measurement Ec/Io. It is used for cell
reselection process. The greater the value is, the less is the probability of reselecting the UMTS
neighboring cell
Value range: 0~20
Physical value range: 0 ~ 40; step: 2.
Physical unit: dB.
Step 4: Reselection delay time
Reselection delay time: If the signal quality of a neighboring cell is better than the serving cell
during the specified time of this parameter, the UE will reselect the neighboring cell. It is used to
avoid ping-pong reselection between different cells.
Huawei Confidential 4 of 5
Intra-frequency Cell Reselection Parameters Specification
Value range: 0~31
Physical unit: second.
Step 5: Trigger UMTS serving cell to UMTS neighbor cell reselection
Huawei Confidential 5 of 5