INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved...
Transcript of INTERNAL SQUARE CORNER - DIRECT FIXED€¦ · concrete slab floor - direct fixed approved...
INTERNAL SQUARE CORNER - DIRECT FIXED
SELECTED PLASTER FINISH
ADDITIONAL FRAMING ISREQUIRED IN ALL INTERNALCORNERS (I.E. DOUBLESTUDS)
NOVEMBER 2010
APPROVED PROPRIETARYBREATHER TYPE SARKINGCONTINUOUS AROUNDCORNER FIXED OVERFRAMING BY BUILDER
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
EXTERNAL SQUARE CORNER - DIRECT FIXED
SELECTED PLASTER FINISH
20 x 20 PVC CORNER BEND
APPROVED PROPRIETARYBREATHER TYPE SARKINGCONTINUOUS AROUNDCORNER FIXED OVERFRAMING BY BUILDER
NOVEMBER 2010
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
50
CONCRETE SLAB FLOOR - DIRECT FIXED
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND
100mm TO PAVED GROUND175mm TO UNPAVED GROUND
D.P.C
NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
50
TIMBER FLOOR FOUNDATION - DIRECT FIXED
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND100mm TO PAVEDGROUND175mm TO UNPAVEDGROUND
NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
SELECTED FLOORING
TIMBER FLOOR FOUNDATION - DIRECT FIXED
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND
NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
SELECTEDFLOORING
50mm m
in
REBATED CONCRETE SLAB FLOOR - DIRECT FIXED
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
D.P.C
NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
REBATE IN THE SLAB MUST BECOMPLETELY WATERPROOFED WITHA PROPRIETARY TANKING MEMBRANEAS SPECIFIED BY THE DESIGNER.INSTALLED BY OTHERS.
6mm MS SEALANT JOINT AGAINSTPEF BACKING ROD
PVC L BEND
35mm
35mm
ROOF / WALL JUNCTION - DIRECT FIXED
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND
min.
FLASHING MUST EXTEND AMINIMUM OF 75mm BEHINDCLADDING AND MUST BETAPED ONTO THE SARKINGWITH WATERPROOFMEMBRANE TAPE BY BUILDER
SELECTED ROOFING WITHSTOP ENDS
10min
MS SEALANT OVER COMPRESSEDFOAM BACKING ROD
SELECTED PIPE
SARKING TAPED ONTO PIPE USINGWATERPROOF MEMBRANE BYOTHERS. WRAP FLASHING TAPE25mm AROUND PIPE AND 100mmONTO SARKING
TIMBER PACKING INSTALLED BYBUILDER
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
PIPE PENETRATION - DIRECT FIXEDNOVEMBER 2010
COMMENT: WHERE POSSIBLEPIPE PENETRATIONS SHOULD BEINSTALLED SLOPING DOWN
SOFFIT DETAIL - DIRECT FIXEDNOVEMBER 2010
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
INSULCLAD PRE-MESHEDBOARD OR EPS SHEET
NOGGING AS REQUIRED FORINSULCLAD BOARD FIXINGINSTALLED BY THE BUILDER
SOFFIT LINING
VERTICAL CONTROL JOINT - DIRECT FIXED
SELECTED PLASTER FINISH
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
PVC L BEND
ADDITIONAL FRAMING WILLBE REQUIRED WITH 35mm STUDS
PEF BACKING ROD AND SEALANTBETWEEN 8 - 10mm GAP
100mm WIDE FLASHINGBEHIND CONTROL JOINT
FIXING BLOCK - DIRECT FIXEDNOVEMBER 2010
H3 TREATED TIMBER BLOCKING CUTTO SUIT POLY THICKNESS ANDAPPLIED OVER SARKING BY THEBUILDER
SELECTED PLASTER FINISH
APPROVED BREATHER TYPESARKING INSTALLED BY BUILDER
WATERPROOF MEMBRANE PATCHMUST COVER ALL SIDES OFFIXING BLOCK BY 50mm
METER BOX - HEAD AND JAMB - DIRECT FIXED
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND
NOTE:METER BOXES MUST BE INSTALLED IN SHELTERED LOCATIONS
EXTRA NOGGINGAS REQUIRED
5mm BEAD OF MS SEALANT BACKEDBY A COMPRESSED FOAM BACKING ROD
METER BOX TAPED ONTO SARKINGUSING WATERPROOF MEMBRANE BYBUILDER - TAPE TO EXTEND MIN 100mmONTO SARKING AND MIN. 50mm ONTO BOX
METER BOX
10mm
WINDOW H
EAD - D
IRECT FIXED
APPROVED PROPRIETARY BREATHER
TYPE SARKING FOLDED IN
TO
OPENING, IN
STALLED BY BUILDER
NOVEMBER 2010
INSULCLAD PRE-M
ESHED BOARD
OR EPS SHEET
DRIP EDGE FORMED IN
PLASTER
PVC L BEND
SEALANT JOINT
AS 2047 COMPLIANT
WINDOW JOINERY
REVEAL
POLYURETHANE FOAM
AIRSEAL O
VER PEF ROD
INTERNAL LINING
FLASHING TAPE TO CORNERS
WINDOW SILL - D
IRECT FIXED
NOVEMBER 2010
POLYURETHANE FOAM
AIRSEAL O
VER PEF ROD
10mm
APPROVED PROPRIETARY BREATHER
TYPE SARKING FOLDED IN
TO
OPENING, IN
STALLED BY BUILDER
AS 2047 COMPLIANT
WINDOW JOINERY
REVEAL
SILL FLASHING TO DRAIN W
ATER
FROM SILL AND JAMB
FLASHING TAPE ALONG SILL,
100mm UP JAMB AND 50mm
ONTO FACE O
F SARKING
EPS BOARD CUT O
N 15°
SLOPE AT SILL
INSULCLAD PLASTER SYSTEM
10mm
WINDOW JAMB - D
IRECT FIXED
NOVEMBER 2010
APPROVED PROPRIETARY BREATHER
TYPE SARKING FOLDED IN
TO
OPENING, IN
STALLED BY BUILDER
INSULCLAD PRE-M
ESHED BOARD
OR EPS SHEET
PVC L BEND
SEALANT JOINT
FLASHING TAPE TO CORNERS
AS 2047 COMPLIANT
WINDOW JOINERY
REVEAL
POLYURETHANE FOAM
AIRSEAL O
VER PEF ROD
INTERNAL LINING
INSULCLAD PLASTER SYSTEM
INTERNAL SQUARE CORNER - CAVITY
SELECTED PLASTER FINISH
ADDITIONAL FRAMING ISREQUIRED IN ALL INTERNALCORNERS (I.E. DOUBLESTUDS)
20mm CAVITY
NOVEMBER 2010
APPROVED PROPRIETARYBREATHER TYPE SARKINGCONTINUOUS AROUNDCORNER FIXED OVERFRAMING BY BUILDER
VERTICAL 50mm x 20mm CAVITYBATTENS
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
EXTERNAL SQUARE CORNER - CAVITY
SELECTED PLASTER FINISH
20 x 20 PVC CORNER BEND
APPROVED PROPRIETARYBREATHER TYPE SARKINGCONTINUOUS AROUNDCORNER FIXED OVERFRAMING BY BUILDER
NOVEMBER 2010
20mm CAVITY
VERTICAL 50mm x 20mm CAVITYBATTENS
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
50
15
CONCRETE SLAB FLOOR - CAVITY
CAVITY PACKERS 100mm LONGAT FIXINGS
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
20mm CAVITY
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND
VENT STRIP100mm TO PAVED GROUND175mm TO UNPAVED GROUND
D.P.C
NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
50
15
TIMBER FLOOR FOUNDATION - CAVITY
CAVITY PACKERS 100mm LONGAT FIXINGS
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
20mm CAVITY
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND
VENT STRIP
100mm TO PAVEDGROUND175mm TO UNPAVEDGROUND
NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
SELECTED FLOORING
PIER FOUNDATION - CAVITY
CAVITY PACKERS 100mm LONGAT FIXINGS
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
20mm CAVITY
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND
VENT STRIP
NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
SELECTEDFLOORING
50mm m
in
REBATED CONCRETE SLAB FLOOR - CAVITY
CAVITY PACKERS 100mm LONG AT FIXINGS
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
20mm CAVITY
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
D.P.C
NOTE:OPENINGS IN VENTS TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
TYPICAL VENT DETAIL
PROPRIETRY SUBFLOOR VENTS.VENTS TO SIT LEVEL WITH BOTTOMOF REBATE AND TO REMAINUNSEALED ON BOTTOM EDGE,
REBATE IN THE SLAB MUST BECOMPLETELY WATERPROOFED WITHA PROPRIETARY TANKING MEMBRANEAS SPECIFIED BY THE DESIGNER.INSTALLED BY OTHERS.
100mm TO PAVEDGROUND
175mm TO UNPAVEDGROUND
50mm m
in
REBATED CONCRETE SLAB FLOOR - CAVITY(IN BETWEEN VENTS)
CAVITY PACKERS 100mm LONG AT FIXINGS
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
20mm CAVITY
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
D.P.C
NOTE:TERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
REBATE IN THE SLAB MUST BECOMPLETELY WATERPROOFED WITHA PROPRIETARY TANKING MEMBRANEAS SPECIFIED BY THE DESIGNER.INSTALLED BY OTHERS.
6mm MS SEALANT JOINT AGAINSTPEF BACKING ROD
PVC L BEND
PROPREITARY VENTS TO BEINSTALLED AS PER DETAIL
100mm TO PAVEDGROUND
175mm TO UNPAVEDGROUND
35mm m
in
100mm m
in
15
ENCLOSED BALCONY - CAVITY
CAVITY PACKERS 100mm LONG AT FIXINGS
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
20mm CAVITY
INSULCLAD PRE-MESHEDBOARD OR EPS SHEET
SELECTED PLASTER FINISH
NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRETERMITE BARRIERS TO BE INSTALLED AS REQUIRED BY THE BCA. SEEK PROFESIONAL ADVICE
BACKING FOR MEMBRANEUPSTAND
SELECTED FLOORING
SEALANT
NOTE !DESIGN OF THE FLASHINGS AROUNDCANTILEVERED FLOOR JOISTS IS THERESPONSIBILITY OF THE DESIGNER ANDINSTALLATION IS THE RESPONSIBILITY OFTHE BUILDING CONTRACTOR
VENT STRIP TILES
WATER PROOF MEMBRANE ASSPECIFIED BY DESIGNER ANDINSTALLED BY AN INDEPENDANTLICENSED WATERPROOFINGCONTRACTOR
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
50mm x 20mm CAVITY BATTEN
SOFFIT LINING
INSULCLAD PRE-MESHEDBOARD OR EPS SHEET
CANTILIVERED H3 JOISTS
SELECTED FLOORING
70 70mm m
in
15
35mm
PARAPET METAL CAPPING - CAVITYNOVEMBER 2010
NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRE
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
SELECTED PLASTER FINISH
20mm CAVITY
NOTE: CONTINUOUS METALPARAPET (CAP MUST BE SIDE FIXEDBELOW PEF ROD) AS SUPPLIED ANDFITTED BY OTHERS
COMPRESSED PEF BACKING RODINSTALLED BY OTHERS
VENT STRIP
min
H3 TIMBER WEDGE
UNDERLAY TO PROVIDESEPARATION OF METALCAP AND TIMBER
CAVITY PACKERS 100mmLONG AT FIXINGS
NOTE; IF ROOF IS BEINGUSED AS AN INTERNALGUTTER, THE CLADDINGMUST BE MIN. 100mm ABOVEMEMBRANE SURFACE
WATER PROOFING EXTENDMIN. 150mm UP ANYVERTICAL SURFACE
5° min slope
INSULCLAD PRE-MESHEDBOARD OR EPS SHEET
35mm 15
BALCONY CAPPING - CAVITYNOVEMBER 2010
NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRE
min
CAVITY PACKERS 100mm LONG
WATERPROOFING MEMBRANEMUST EXTEND A MINIMUM OF150mm UP ANY VERTICALSURFACE
INSULCLAD BOARD MUSTBE CAPPED 35mm ABOVEFINISHED BALCONY LEVEL
15° min slope
3mm THICK EPDMGASKET BETWEENPLASTER & BRACKET
TIMBER BLOCK MUST BE COVEREDWITH A WATERPROOF MEMBRANEPATCH COVERING INSULCLADBOARD BY A MIN. OF 50mm
DRESSED H3 FIXING BLOCKS MUST BEPLACED AT THE FRONT OR BACK OFWALL NOT THE TOP, BY BUILDER
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
SELECTED PLASTER FINISH
20mm CAVITY
PVC L BEND
VENT STRIP
TWO LAYERS OF REINFORCINGFIBREGLASS MESH OVERSURFACE OF EIFS TAPEMEMBRANE EXTEND DOWN EACHSIDE MIN. DISTANCE OF 50mm
6mm O/HANG
30mm
FLUSH EAVES - CAVITYNOVEMBER 2010
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
SELECTED PLASTER FINISH
20mm CAVITY
PEF ROD
BEAD OF MS SEALANT IF NECESSARY
SOLID BLOCKING TO CLOSEOFF CAVITY AT TOP OF WALL
CAVITY BATTEN
INSULCLAD PRE-MESHEDBOARD OR EPS SHEET
MIN
SELECTED ROOFING
15
35mm
35mm
ROOF / WALL JUNCTION - CAVITY
CAVITY PACKERS 100mm LONG AT FIXINGS
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
20mm CAVITY
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND
VENT STRIP
NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRE
min.
FLASHING MUST EXTEND AMINIMUM OF 75mm BEHINDCLADDING AND MUST BETAPED ONTO THE SARKINGWITH WATERPROOFMEMBRANE TAPE BY BUILDER
SELECTED ROOFING WITHSTOP ENDS
10min
INSULCLAD PRE-MESHEDBOARD OR EPS SHEET
MS SEALANT OVER COMPRESSEDFOAM BACKING ROD
SELECTED PIPE
SARKING TAPED ONTO PIPE USINGWATERPROOF MEMBRANE BYOTHERS. WRAP FLASHING TAPE25mm AROUND PIPE AND 100mmONTO SARKING
CAVITY PACKER TO SUPPORT SHEETEDGE
TIMBER PACKING INSTALLED BYBUILDER
20mm CAVITY
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
PIPE PENETRATION - CAVITYNOVEMBER 2010
COMMENT: WHERE POSSIBLEPIPE PENETRATIONS SHOULD BEINSTALLED SLOPING DOWN
SOFFIT DETAIL - CAVITYNOVEMBER 2010
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
20mm CAVITY
INSULCLAD PRE-MESHEDBOARD OR EPS SHEET
NOGGING AS REQUIRED FORINSULCLAD BOARD FIXINGINSTALLED BY THE BUILDER
SOFFIT LINING
CAVITY BATTEN
NOTE:CAVITY MUST NOT BE ALLOWEDTO VENT INTO ROOF SPACE
15
SOFFIT EDGE DETAIL - CAVITY
CAVITY PACKERS 100mm LONG AT FIXINGS
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
20mm CAVITY
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
PVC L BEND
VENT STRIP
NOTE:PUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF 1000mm² PER LINEAL METRE
SELECTED SOFFIT
12mm min
VERTICAL CONTROL JOINT - CAVITY
SELECTED PLASTER FINISH
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
PVC L BEND
ADDITIONAL FRAMING WILLBE REQUIRED WITH 35mm STUDS
CAVITY BATTEN
PEF BACKING ROD AND SEALANTBETWEEN 8 - 10mm GAP
FIXING BLOCK - CAVITYNOVEMBER 2010
100x100mm H3 TREATED TIMBERBLOCKING CUT TO SUIT POLYTHICKNESS AND APPLIED OVERSARKING BY THE BUILDER
SELECTED PLASTER FINISH
CAVITY PACKERS - 100mm LONG
APPROVED BREATHER TYPESARKING INSTALLED BY BUILDER
WATERPROOF MEMBRANE PATCHMUST COVER ALL SIDES OFFIXING BLOCK BY 50mm
35
80
15
INTERSTOREY DRAINAGE JOINT - CAVITYNOVEMBER 2010
SELECTED PLASTER FINISH
NOTE:THIS DETAIL IS REQUIRED AT THE SECOND STOREY JOIST LEVELPUNCHINGS IN VENT STRIP TO PROVIDE VENTILATION OPENINGS OF1000mm² PER LINEAL METRE
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
CAVITY PACKERS - 100mm LONGAT FIXINGS
APPROVED BREATHER TYPESARKING INSTALLED BY BUILDER
5mm GAP
METAL FLASHING WITH A 15°SLOPE EXTENDING 75mm BEHINDCLADDING AS SUPPLIED ANDINSTALLED BY OTHERS
VENT STRIP
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
100mm
METER BOX - HEAD AND JAMB - CAVITY
APPROVED PROPRIETARYBREATHER TYPE SARKINGINSTALLED BY BUILDER
NOVEMBER 2010
INSULCLAD PRE-MESHED BOARDOR EPS SHEET
SELECTED PLASTER FINISH
PVC L BEND
EXTRA NOGGINGAS REQUIRED
5mm BEAD OF MS SEALANT BACKEDBY A COMPRESSED FOAM BACKING ROD
METER BOX TAPED ONTO SARKINGUSING WATERPROOF MEMBRANE BYBUILDER - TAPE TO EXTEND MIN 100mmONTO SARKING AND MIN. 50mm ONTO BOX
METER BOX
CAVITY BATTEN
20mm CAVITY
JAMB
HEAD
WATERPROOF MEMBRANE TAPE
CAVITY BATTEN
EPS WEDGE TAPED TO SARKING WITHFLASHING TAPE
CAVITY BATTEN
METER BOX
min
100mm GAP LEFT IN CAVITY BATTEN TOALLOW DRAINAGE INTO NEXT CAVITY
5mm gap
10mm m
in. c
over
35mm min. cover
to flashing
10mm
AS 2047 COMPLIANT
WINDOW JOINERY
REVEAL
POLYURETHANE FOAM
AIRSEAL O
VER PEF ROD
INTERNAL LINING
WINDOW SILL - C
AVITY
NOVEMBER 2010
POLYURETHANE FOAM
AIRSEAL O
VER PEF ROD
10mm
APPROVED PROPRIETARY
BREATHER TYPE SARKING
FOLDED IN
TO O
PENING,
INSTALLED BY BUILDER
REVEAL
WINDOW H
EAD - C
AVITY
NOVEMBER 2010
FLASHING TAPE ALONG SILL,
100mm UP JAMB AND 50mm
ONTO FACE O
F SARKING
EPS BOARD CUT O
N 15°
SLOPE AT SILL
INSULCLAD PLASTER SYSTEM
AS 2047 COMPLIANT
WINDOW JOINERY
SILL FLASHING TO DRAIN W
ATER
FROM SILL AND JAMB
10mm
WIN
DOW JAMB - C
AVITY
NOVEMBER 2010
APPROVED PROPRIETARY BREATHER
TYPE SARKING FOLDED IN
TO
OPENING, IN
STALLED BY BUILDER
INSULCLAD PRE-M
ESHED BOARD
OR EPS SHEET
PVC L BEND
SEALANT JOINT
FLASHING TAPE TO CORNERS
AS 2047 COMPLIANT
WINDOW JOINERY
REVEAL
POLYURETHANE FOAM
AIRSEAL O
VER PEF ROD
INTERNAL LINING
INSULCLAD PLASTER SYSTEM
APPROVED PROPRIETARY
BREATHER TYPE SARKING
FOLDED IN
TO O
PENING,
INSTALLED BY BUILDER
INSULCLAD PRE-M
ESHED BOARD
OR EPS SHEET
PVC L BEND
ADDITIO
NAL FLASHING TAPE O
VER
HEAD FLASHING AND SARKING
STOPENDS TO HEAD FLASHING
CAVITY PACKERS 100mm LONG AT FIXINGS
CAVITY BATTENS
DOOR
WINDOW
Foundation
Control joint
Selected Flooring
Ceiling Batten Soffit Ribbon Plate
Floor Joist
Battens or packerslocated no closerthan 100mm fromedge of opening
Expansionjoint
TYPIC
AL BATTEN LAYOUT
NOTES:
• If additio
nal w
all in
sulatio
n is being in
stalled, th
e sarking m
ust b
e supporte
d by p
olyp
ropyle
ne
builders stra
p stapled along th
e wall a
t 300mm centre
s to
stop th
e wrap bulging.
• All h
oriz
ontal b
atte
ns m
ust b
e applied on a m
inim
um slope of 1
5 degrees and be no lo
nger
than 100mm in
length. (O
nly o
ne horiz
ontal p
acker m
ay b
e placed between vertic
al b
atte
ns.)