The presentation that follows lists only one combination of partsObviously the clinical situation may call for substitution of another part on this slide
Healing abutment in place
![Page 3: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/3.jpg)
Internal Hex UCLA Abutment
Prosthetic instruments needed
![Page 4: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/4.jpg)
Internal Hex UCLA Abutment
Remove healing abutmentfrom implantAssemble screw driver with
Thumb Knob
![Page 5: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/5.jpg)
Insert the Impression Transfer into the implant ensuring the appropriate orientation
Internal Hex UCLA Abutment
Tighten the screw with the driver assembly with light finger force
![Page 6: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/6.jpg)
Remove driver
Internal Hex UCLA Abutment
Apply wax to the top of the screw.
![Page 7: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/7.jpg)
Inject impression material around the abutment
Internal Hex UCLA Abutment
![Page 8: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/8.jpg)
Internal Hex UCLA Abutment
Insert tray with impression materialSeat impression to capture dental arch
![Page 9: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/9.jpg)
Internal Hex UCLA Abutment
Remove the impression from the mouth when material has set
![Page 10: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/10.jpg)
Internal Hex UCLA Abutment
Remove impression transfer from implant
Use a sharp instrument to remove the wax from the screw
![Page 11: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/11.jpg)
Healing abutment in place
Internal Hex UCLA Abutment
Insert healing abutment into implant
![Page 12: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/12.jpg)
Internal Hex UCLA Abutment
Insert driver into Impression Transfer
Insert Impression Transfer into implant level analog and tighten fixation screw with finger pressure
![Page 13: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/13.jpg)
Internal Hex UCLA Abutment
Assembled Impression Transfer with implant level analog
Insert transfer/analogassembly into impression
UCLA Abutment/Analogassembly inside impression
![Page 14: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/14.jpg)
Apply soft tissue replica material around implant level analog
Internal Hex UCLA Abutment
Pour dental stone into impression
![Page 15: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/15.jpg)
Internal Hex UCLA Abutment
Remove model from impression and loosen the fixation screw of the impression transfer by turning screw driver counter clockwise
Remove impression transfer from analog
![Page 16: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/16.jpg)
Internal Hex UCLA Abutment
Insert the UCLA abutment into the implant level analog ensuring the appropriate orientation. Hand tighten the fixation screw within the UCLA abutment
Insert screw driverassembly into fixation screw in the UCLA abutment
![Page 17: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/17.jpg)
Internal Hex UCLA Abutment
Cast and finish custom UCLA abutment
Create a wax up of the desired shape of the abutment by subtracting or adding to the resin of the UCLA abutment
![Page 18: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/18.jpg)
Internal Hex UCLA Abutment
Seal the screw opening of the UCLA Abutment
Apply die spacer and wax up undercasting on the UCLA Abutment
![Page 19: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/19.jpg)
Porcelain crown on model
Internal Hex UCLA Abutment
Cast wax up using a conventional technique and insert it in the casting on the stone model
Stack and fire the Ceramic in the usual manner
![Page 20: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/20.jpg)
Internal Hex UCLA Abutment
Insert the abutment into implant orienting it according to the instructions from the laboratory and tighten with driver
![Page 21: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/21.jpg)
Internal Hex UCLA Abutment
Insert driver into the abutment screw tighten the screw until torque of 30 Ncm is reached and the head of the ratchet releasesInsert the hex driver into the
30Ncm torque ratchet
![Page 22: Internal Hex UCLA Abutment Procedure](https://reader034.fdocuments.net/reader034/viewer/2022042609/568c39911a28ab0235a2d355/html5/thumbnails/22.jpg)
Internal Hex UCLA Abutment
Cement restoration on abutment