Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator &...

8
HEADQUARTERS Industrial zone 861-10, Taegye-dong, Chunchon-si, Kangwon-do, Korea 200-244 > Tel : +82-33-264-5926 > Fax : +82-33-264-5999 > E-mail : [email protected] Specification subject to be changed without notice P/N:MEK-CAT-001-20100317 Rev.1.0 April. 2010. Designed by BizPlus AD Inc. www.bizplusad.co.kr Intensive Care Ventilator & Patient Monitor Product Catalogue www.mek-ics.com

Transcript of Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator &...

Page 1: Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator & Patient Monitor Product Catalogue 02/03 MEK-ICS was established in 1998. focus on life

HEADQUARTERSIndustrial zone 861-10, Taegye-dong, Chunchon-si, Kangwon-do, Korea 200-244> Tel : +82-33-264-5926 > Fax : +82-33-264-5999 > E-mail : [email protected]

Specification subject to be changed without notice

P/N:MEK-CAT-001-20100317 Rev.1.0 April

. 201

0. D

esig

ned

by B

izPlu

s AD

Inc.

www

.bizp

lusa

d.co

.kr

Intensive Care Ventilator & Patient Monitor

Product Catalogue

www.mek-ics.com

Page 2: Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator & Patient Monitor Product Catalogue 02/03 MEK-ICS was established in 1998. focus on life

Intensive Care Ventilator & Patient Monitor

Product Catalogue

02/03

MEK-ICS was established in 1998.

focus on life care,

have developed Bio-signal Modules,

Intensive Care Ventilator and Patient Monitor, Pulse Oximeter.

pursue more complete solution for Life care.

Intensive Care Ventilator & Patient Monitor

VentilatorMV2000 ���������������04MV2500 (Domestic Model) ��������04MC200 ����������������04

Patient MonitorMP1300 ���������������06MP1000NTP ��������������07MP800 ����������������08MP700 ����������������09MP600 ����������������09

Pulse OximeterMP110 Plus ��������������10MP111 ����������������10MP570T ���������������11

EtCO2 MonitorMP800C ���������������11

Phototherapy UnitMH200 ����������������12

Veterinary MonitorMP1000NTP Vet ������������13MP800 Vet ��������������13

Bio signal ModuleSpO2 ����������������14ECG �����������������15NIBP �����������������15

Page 3: Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator & Patient Monitor Product Catalogue 02/03 MEK-ICS was established in 1998. focus on life

Intensive Care Ventilator & Patient Monitor 04/05

Intensive Care Ventilator

MV2000MV2500 (Domestic Model)

Specifications

MV2000 / MV2500

Wide Application Range Applications : Neonate and Pediatric to Adult Ideal Body Weight Setting : 3kg~150kg Tidal Volume : 5ml to 2500ml

Ventilation Mode (All in One) Breath Type : Volume & Pressure Control Ventilation Standard Mode : ACV, SIMV+PPS, CPAP+PPS Special Mode : NIV, t-Bilevel, PRVC

Apnea Back-up Ventilation, Emergency Auto

Ideal Body Weight Setting Automatic setting in all parameter by body weight Volume limitation by body weight : 15[ml/kg] × weight[kg] User selectable body weight factor : 5 ~ 15 ml/kg

Special Functions Graphic I : E Ratio ViewerFend%(Flexible Inspiration Flow Pattern)Built-in NebulizerUp to 72hours graphic and tabular trendEx-sense%(Adjustable expiratory sensitivity)En-sense%(Preventive solution for auto-trigger)

Ventilator SettingBreath Type Volume and Pressure Ventilation Mode ACV, SIMV, Spontaneous

Bi-Level, PRVC, NIV, AutoPositive Pressure SupportApnea Back-up ventilation

IBW 3kg ~ 150kgTidal volume 5ml ~ 2500 mlInspiratory pressure 5 ~ 80 cmH2OInspiratory pressure limit 3 ~ 80 cmH2O(PRVC mode)Pressure support 0 ~ 60 cmH2ORespiratory rate 2 to 120 BPMI:E ratio 10:1 - 1:99Inspiratory time 0.2 ~ 9.9 secPlateau time 0 ~ 2.0 secInspiratory rising time 0.1 ~ 0.5 secPEEP 0 ~ 45 cmH2OHigh PEEP 5 ~ 45 cmH2OLow PEEP 0 ~ 45 cmH2OHigh PEEP time 0.2 ~ 9.9 secLow PEEP time 0.2 ~ 24 secEx-sense%(adj. exp. sensitivity) 10 ~ 60%En-sense%(reduce auto-trigger) 10 ~ 60%F-end(Insp. Flow Pattern) 25 ~ 100%Inspiratory flow rate 1 ~ 180 lpmTrigger sensitivity Pressure (0.5 ~ 20 cmH2O)

Flow (0.5 ~ 20 lpm)O2 21 ~ 100%Ideal body weight factor 5 ~ 15 ml/kgSigh, Tidal volume x 1.5 Off, 1 ~5 BPMHumidification type HME, Heated humidifierAltitude -100 ~ 5000m

Other key and IndicatorsNebulizer 10 ~ 180 min. Auto & ManualInspiration pause Resistance, ComplianceExpiration pause Auto-PEEPManual inspiration Setting tidal volume100% O2 100% oxygen for 3 minutesKey lock Function key lock

Dimensions / WeightMain unit W33×D25×H40 cm 30kgDisplay monitor W48×D6×H28 cm 7kgMobile cart W48×D57×H77 cm 20kgCompressor W30×D43×H44 cm 30kgInspiratory limb connector:ISO22mm conical maleExpiratory limb connector:ISO22mm conical maleAir and Oxygen inlets:DISS male/female

Monitoring DataVentilation mode and Ideal Body WeightTotal Respiration RateVolume(Insp. Tidal, Exp. Tidal, Exp. Minute)Pressure(Peak, Mean, Pause, PEEP)Spontaneous Exp. Minute Volume, Spontaneous RateRapid Shallow Breathing IndexHigh PEEP and Low PEEP(Bi-level Mode)Dynamic ComplianceReal Time Flow Rate(Insp., Exp., End Expiratory)Peak Flow RateDelivered O2 %Graphic I:E ratio (I-Time/E-Time)Pressure, Flow, Volume CurvePressure-Volume loop curveFlow-Volume curve.72hours Graphic and Tabular trendRSBI(Rapid Shallow Breathing Index)P 0.1 measurementTi / Ttot RatioEvent logCompliance graphic

AlarmsHigh pressure, Low pressureHigh tidal volume, Low tidal volumeHigh minute volume, Low minute volumeHigh respiration rateApneaHigh PEEP, Low PEEPPower lossWall O2/Air low inlet pressureHigh O2. Low O2

Obstructed tubeAirway leakCircuit openVentilator in-operationAlarm silenceAlarm reset

Power input100 ~ 230 VAC, 50/60 Hz (Free voltage)12VDC 7A External power input12VDC 7A Internal battery operating, Max. 180 minutesPower consumption : 84W(main unit only)

Ventilator

Option (International Sale)

Touch Screen for MV2000• 12.1-inch TFT Color Display

• User selectable waveform colors

• User configuration waveform display

Air Compressor Unit

MC200• Available to install inside MV2000 moving cart

• Low vibration & Low noise below 50dB

• Smart protection for humidity & dust

• Enable to supply Max. 2 units of MV2000

Page 4: Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator & Patient Monitor Product Catalogue 02/03 MEK-ICS was established in 1998. focus on life

Intensive Care Ventilator & Patient Monitor 06/07

Intensive Care Patient Monitor

MP1300Intensive Care Patient Monitor

MP1000NTP• 12.1” Touch screen TFT color LCD

• 8 waveform display

• ECG, RESP, SpO2, NIBP, 4-IBP, 2-Temp. EtCO2, Multi-Gas, Cardiac Output

• Full Arrhythmia analysis and ST segment analysis

• Save up to 30 event management

• Oxy-CRG for management of neonatal intensive care patients

• Virtual screen system for various viewing

• 72-hours tabular and graphic trend

• Selectable color configuration for all parameters

• 10.4” superior resolution TFT color LCD

• 7 waveform display

• ECG, RESP, SpO2, NIBP, 2-IBP, 2-Temp. EtCO2

• Full Arrhythmia analysis and ST segment analysis

• Save up to 30 event management

• Virtual screen system for various viewing

• 72-hours tabular and graphic trend

• Selectable color configuration for all parameters

Patient Monitor

DisplayDisplay 12.1” Color TFT LCDResolution 800 × 600 SVGA Trace line 8 waveform

ECGChannel 3 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s

Artifact recovery time<8sPacemaker detection/rejectionST segment analysisArrhythmia analysisHRV measurement

RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpmAccuracy ±1bpmImpedance range 100 ~ 2000 ohmsDetect sensitivity 0.5 ohm min

SpO2

Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, Neonatal, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%Perfusion Index 0.05~20%PWV measurement

Multi Gas(Option)Parameters CO2, O2, N2O, Anesthetic Agent Gas

Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systolic, Diastolic, Mean

Last 3 measurementAuto deflation pressure Adult 300 mmHg / Neonate 150 mmHgSTAT Mode 5~15 min. of consecutiveMeasurement time max. 40 sec.

Invasive blood pressureNumber of channel Max. 4-channelMeasurement range -50~300mmHgLabel ART, FEM, PA, CVP, LA, RA, ICP, SPSensor 5uV/mmHg (Optional)Accuracy ±2%Biasing and Scaling Automatic for BP signal display

Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)

EtCO2(Option)Measurement range 0-99 mmHgRespiration range 0~150 bpmAccuracy ±2 mmHg, 0~38 mmHg / ±5%, 39~99 mmHgSampling rate 50ml/minRespiration rate range 2 ~ 150 bpm Cardiac Output(Option)Method ThermodilutionCardiac Output range 0.1~15 LPMParameters CI, SV, SI, LVSW, LVSWI, RVSW, RVSWI,

SVR, SVRI, PVR, PVRIBlood temp. range 23 ~ 43°CInjactate temp. range 0 ~ 27°C

DisplayDisplay 10.4” Color TFT LCDResolution 800 × 600 SVGA Trace line 7 waveform

ECGChannel 3 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s

Artifact recovery time<8sPacemaker detection/rejectionST segment analysisArrhythmia analysis

RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpmAccuracy ±1bpmImpedance range 100 ~ 2000 ohmsDetect sensitivity 0.5 ohm min

SpO2

Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, neonate, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%

Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systolic, Diastolic, Mean

Last 3 measurementAuto deflation pressure Adult 300 mmHg Neonate 150 mmHgSTAT Mode 5~15 min. of consecutiveMeasurement time max. 40 sec.

Invasive blood pressureNumber of channel Max. 4-channelMeasurement range -50~300mmHgLabel ART, FEM, PA, CVP, LA, RA, ICP, SPSensor 5uV/mmHg (Optional)Accuracy ±2%Biasing and Scaling Automatic for BP signal display

Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)

EtCO2(Option)Measurement range 0-99 mmHgRespiration range 0~150 bpmAccuracy ±2 mmHg, 0~38 mmHg ±5%, 38~99 mmHgSampling rate 50ml/minRespiration rate range 2 ~ 150 bpm

Page 5: Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator & Patient Monitor Product Catalogue 02/03 MEK-ICS was established in 1998. focus on life

Intensive Care Ventilator & Patient Monitor 08/09

Semi Modularized Patient Monitor

MP800(PAMO II)

Semi Modularized Patient Monitor

MP700(PAMO I)

• 6.4” high quality resolution TFT color LCD

• 3/5-lead ECG, RESP, SpO2, NIBP, TEMP.

• Arrhythmia Analysis, ST segment, Pacemaker detector

• Virtual screen system for various viewing

• 72hours tabular and graphic trend

• ECG lead auto detection (3 lead or 5 lead)

• Smart and Compact size monitor

• 3/5-lead ECG, SpO2, NIBP, TEMP.

• Arrhythmia Analysis, ST segment, Pacemaker detector

• Back light Blue LCD display

• 72hours trend of HR and the other vital signs value

• Option - 58mm Thermal Printer, LAN networking capacity

Central Monitoring System

MP600• Up to 32 bed patient monitor

• Easy user interface with pop-up menu

• 72 hours graphic trend for each patient

• Save up to 200,000 case alarm event at 60G HDD

• Various display selectable

• Arrhythmia and ST segment display and Analysis

• LAN network

DisplayDisplay 5.5” Blue LCDResolution 240 x 128 Trace line 2 waveformTrend 72hrs of all vital signs

ECG Channel 1 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Dynamic range 10mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s

Artifact recovery time<8sPacemaker detection/rejectionST segment analysisArrhythmia analysis

SpO2

Range 0 ~ 100%Mode Selection Adult, neonate, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%

Non-invasive blood pressureMeasurement range 0~300 mmHgAuto defleation pressure Adult 300 mmHg Neonate 150 mmHgSTAT Mode 5~15 min. of consecutiveAutomatic Measurement 1,2,3,5,10,20,30 minutes Cycles 1,2,4,6,8,10 hoursMeasurement time max. 40 sec.

Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)

Patient Monitor

DisplayDisplay 6.4” Color TFT LCDResolution 320 × 240 VGA Trace line 2 waveformTrend 72hrs Graphic and Tabular

ECGChannel 1 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s

Artifact recovery time<8sPacemaker detection/rejectionST segment analysisArrhythmia analysis

RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpmAccuracy ±1bpmImpedance range 100 ~ 2000 ohmsDetect sensitivity 0.5 ohm min

SpO2

Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, neonate, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%

Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systolic, Diastolic, Mean

Last 3 measurementAuto deflation pressure Adult 300 mmHg Neonate 150 mmHgSTAT Mode 5~15 min. of consecutiveMeasurement time max. 40 sec.

Temperature (1-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)

Page 6: Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator & Patient Monitor Product Catalogue 02/03 MEK-ICS was established in 1998. focus on life

Intensive Care Ventilator & Patient Monitor 10/11

Hand Held Pulse Oximeter

MP110 PlusHand Held Pulse Oximeter

MP111Pulse Oximeter

MP570T

• Small size and light weight (400g)

• Back-light blue LCD Display

• Alarm silence mode(30sec.)

• Fast set-up time

• Long battery operation time (8 hours)

• Performance elevated for Low perfusion patient and Neonate

• Small size and light weight (400g)

• Back-light blue LCD Display

• Alarm silence mode(30sec.)

• Fast set-up time

• Long battery operation time (8 hours)

• Performance elevated for Low perfusion patient and Neonate

• 72-hours PR, SpO2 trend display with measured time

• Compact and Deluxe

• Most critically ill patient, Neonate to Adult

• SpO2, Plethysmographic waveform, Pulse rate

• High performance in low perfusion & moving

• Long battery operation (4 hours)

• 120 hours trend/1 minute sacle

• PI(Perfusion index) display

• O2 monitoring

• Smart and compact size gas monitor

• 6.4” TFT color LCD

• EtCO2 +RESP, SpO2

• 72 hours tabular and graphic trend

• Virtual screen display

• Main/Side stream CO2 sensor

• High performance in low perfusion & patient moving

DisplayDisplay 128 × 64 Mono LCDParameters Oxygen saturation and Pulse Rate,

SpO2 wave, Battery indicatedBeep sound on/off, Alarm silence count down Alarm condition, pulse markError massage, Menu display

SpO2

Range 0 ~ 100%Pulse Rate 30 ~ 250 bpmMode Selection Adult, Neonatal, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%

DisplayDisplay 128 × 64 Mono LCDParameters Oxygen saturation and Pulse Rate,

SpO2 wave, Battery indicatedBeep sound on/off, Alarm silence count down Alarm condition, pulse markError massage, Menu display

SpO2

Range 0 ~ 100%Pulse Rate 30~ 250 bpmMode Selection Adult, Neonatal, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%

OptionTrend viewer program

DisplayDisplay 240 × 64 Mono LCDParameters Oxygen saturation and Pulse Rate,

SpO2 wave, PI(perfusion index) Battery indicatedBeep sound on/offAlarm silence count down Alarm condition, pulse markError massage, Menu display

SpO2

Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, Neonatal, Auto modeAccuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%

OptionO2 sensor with cable

DisplayDisplay 6.4” Color TFT LCDResolution 320 × 240 VGA Trace line 2 waveformTrend 72hrs Graphic and Tabular

SpO2

Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, neonatal, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%

EtCO2(Option)Measurement range 0-99 mmHgAccuracy ±2 mmHg, 0~38 mmHg ±5%, 38~99 mmHgSampling rate 50ml/minRespiration rate range 2 ~ 150 bpm

Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)

Pulse Oximeter EtCO2 Monitor

Multi-Parameter Gas Monitor

MP800C

Page 7: Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator & Patient Monitor Product Catalogue 02/03 MEK-ICS was established in 1998. focus on life

Intensive Care Ventilator & Patient Monitor 12/13

Phototherapy Unit

MH200Veterinary Monitor

MP1000NTP VetVeterinary Monitor

MP800 Vet

• Light weight & Compact size

• Special irradiance : 30uW/cm2/nm at 43cm

• Narrow spectrum

• Wave length : 450nm ± 5%

• Normal LED life time : 20,000 hours

• No thermal damage to patient

• 10.4” superior resolution TFT color LCD • 7 waveform display• ECG+Resp, SpO2, NIBP, 2-IBP, 2-Temp.• Full Arrhythmia analysis and ST segment analysis• Save up to 30 event management• Virtual screen system for various viewing• 72-hours tabular and graphic trend

• 6.4” high quality resolution TFT color LCD• 3/5-lead ECG, RESP, SpO2, NIBP, TEMP.• Arrhythmia Analysis and ST segment analysis• Pacemaker Detection• Virtual screen system for various viewing• 72hours tabular and graphic trend• ECG lead auto detection (3 lead or 5 lead)

Phototherapy Unit Veterinary Monitor

Light SourceLamp Blue LCDwavelength Peak between 450nm, ±5%Intensity 12 ~ 30 uw/cm2/nm(@43cm distance)Lamp life time 20000 hours min.

General- 100 ~ 240 VAC, 50/60 Hz (Free voltage)- Power consumption : 35W(main unit only)- Dimensions : W315 × D154 × H50 mm

ECGChannel 3 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%

RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpm

SpO2

Range 0 ~ 100%Pulse Rate 25 ~ 250 bpm

Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systoric, Diastoric, Mean

Last 3 measurement

Invasive blood pressureNumber of channel Max. 2channelMeasurement range -50~300mmHgLabel ART, FEM, PA, CVP, LA, RA, ICP, SP

Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Measurement range 0~50°C

Etco2(Option)Measurement range 0-99 mmHgRespiration range 0~150 bpm

ECGChannel 1 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%

RespirationMathod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpm

SpO2

Range 0 ~ 100%Pulse Rate 25 ~ 250 bpm

Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systoric, Diastoric, Mean

Last 3 measurement

Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Measurement range 0~50°C

Page 8: Intensive Care Ventilator & Patient Monitor Product Catalogue · Intensive Care Ventilator & Patient Monitor Product Catalogue 02/03 MEK-ICS was established in 1998. focus on life

Intensive Care Ventilator & Patient Monitor 14/15

Bio signal Module

Model Grade Description

MM101-T TTL Level Spo2, 2-Temp,2-Ibp (External circuit presented by MEKICS)MM101-S RS232C Level

MM102-T TTL Level Spo2, 2-Temp,2-Ibp, Cardiac output(External circuit presented by MEKICS)MM102-S RS232C Level

SpO2 Module

MM100 series

• Multi Functional Module

- Cardiac Output, SpO2, Temp, IBP

• Strongest to Motion Artifact

• Strongest to Low Perfusion

ECG Module

MM200 seriesNIBP Module

MM300 series

Pulse OximeterSpO2 0~100%Resolution 1%Accuracy ±2%, For Reading 70~100%

±3%, For Reading 50~69%Low Perfusion 0.2% ~ 20%Pulse Rate 20~250 BPMResolution 1 BPMAccuracy ±2%

Invasive Blood PressureNumber of channel 2 channelMeasurement range -50 ~ 300mmHgSensor 5uV/mmHg Accuracy +/-2%

TemperatureNumber of channel 2 channelMeasurement range 0~50°C (Resolution: 0.2°C)Accuracy +/-0.4°C (15~34°C, 41~45°C), +/-0.2°C (34~41°C)Sensor YSI400 Series or

Compatible sensor

Cardiac OutputMethod ThermodilutionCardiac output range 0.1~20 LPMBlood temp. range 23 ~ 43 °CInjectate temp. range 0 ~ 27 °CResolution Cardiac output : 0.1 LPM,

Temperature : +/-0.1°CAccuracy Cardiac output : ±5%,

Temperature : ±0.1°C, Injectate temperature : ±0.1°C

Catheters Edwards compatible(Model: 177f75, 177hf75, 774f75, 774hf75)

GeneralPower Source DC +7.5 ~ +9.0V , 200mA MaxDimensions MM102: W90 × D51 × H15 (mm),

Isolation B/D: W120 x D70 x H20 (mm)Interface RS-232C Baud Rate 19200BPS,

no parity, 8 Bit, 1 Stop bit standardSpO2, Pulse rate, Infra-red wave data, Status MassageStandard : TTL Level - 5V

OptionInterface Direct PC Interface of RS232 STD Level

- Nellcor Compatible Spo2 Sensor, Accessories - Y-Type Spo2 Sensor

- Extension Cable (D-sub type)

ECGChannel 2 or 3 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Dynamic range 10mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s

Artifact recovery time<8sBand wide 0.5~40Hz, 0.5~80Hz, 0.05~40Hz,

0.05~80Hz , monitoring modeESU Protection Yes(@Max. 300W)Lead off detection Yes(LA, RA, LL, RL, V)Pacemaker detection/rejectionST segment analysis -2.0mV ~ +2.0mVArrhythmia analysis , PVC detection, Lead off detection

RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpmAccuracy ±1bpmImpedance range 100 ~ 2000 ohmsDetect sensitivity 0.5 ohm minSensitivity control 10% ~ 90%Frequency response 0.1 ~ 4Hz(-3dB)

GeneralCommunication RS-232C Baud Rate 115KBPS, no parity,

8 Bit, 1 Stop bit standard ECG Heart rate, QRS wave data, Status Massage, Arrhythmia Data, Respiration Rate

Power +7.5V(Single power source)Power Consumption < 2.5WDimensions W145 × D70 × H20 (mm)Operating Temperature Operating Temperature ~ 40°C (50~104°F) Operating Humidity Operating Humidity 10 ~ 90%

Non-invasive blood pressureMeasurement technique Oscillometric Measurement range 0~300mmHg

Accuracy ±2mmHg or ±2%Auto deflation pressure Adult 300mmHg

Neonate 150mmHgShut Down Pressure 330mmHg

GeneralCommunication RS-232C Baud Rate 19200BPS, no partity,

8 Bit, 1 Stop bit standardSystolic, Diastolic, Mean Pressure Result, Pressure, Event MessageStart, Stop, Setting Parameter, Debugging Instruction

Power 12V DC 10%, Ripple & Nosie 5% Max.Power consumption 7.2W Type, ±10%, 600mA

12V Type at InflationDimensions W110 × D82 × H40 (mm)

• Oscillometric / Step down deflation

• Adult/Neonate Mode

• Automatic, STAT Mode

• Reliability good material use

• Lowest Motor Pump Noise

• Self Leakage test Mode

• 2 Channel ECG Wave Form (5-Lead)

• 13 Arrhythmia Analysis / Pacemaker Detection

• ST segment analysis

• Impedance respiration wave form (Lead I or II)

• Strongest to Electrode offset potential

• Including Isolation Power and Communication (CF)