Intel ethernet Controllers and PhYs · 1115/MBR/MESH/PDF Intel® ethernet Controllers and PhYs....

2
Copyright © 2015 Intel Corporation. All rights reserved. Intel and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. 320117-009US Driver Support VMWare ESX* Windows Server 2012 R2 Windows Server 2012 Microsoft Windows 7* Microsoft Windows Vista* (32 & 64 bit) Microsoft Windows XP* (32 & 64 bit) Microsoft Windows CE* Microsoft Windows NT* Microsoft Windows Server 2003* (32 & 64 bit) Microsoft Windows 2000 Server* Microsoft DOS* Linux* Kernel.org IB tree SUSE Linux Enterprise Server* Red Hat Enterprise Linux* FreeBSD* Solaris* SCO UnixWare* 7.x Open Unix* 8.0 Novell ODI* Novell Netware* Intel® Advanced Networking Services Teaming Initiate a team with up to eight NICs. Multi-Vendor Teaming Allows teaming with third-party NICs and LOM solutions. Adapter Fault Tolerance Provides automatic redundancy for the server’s network connection should the primary adapter fail. Transmit and Receive Load Balancing Balances network traffic across teamed network connections. 802.1q VLAN Tagging Allows teaming in multiple sub-networks by creating virtual adapters. Link Aggregation Supports Intel® Link Aggregation, Fast EtherChannel, Gigabit EtherChannel, and IEEE 802.3ad standards. Continues to balance traffic even if one of the teamed connections loses link. 1115/MBR/MESH/PDF www.intel.com/ethernet INTEL ® ETHERNET CONTROLLERS AND PHYS

Transcript of Intel ethernet Controllers and PhYs · 1115/MBR/MESH/PDF Intel® ethernet Controllers and PhYs....

Page 1: Intel ethernet Controllers and PhYs · 1115/MBR/MESH/PDF  Intel® ethernet Controllers and PhYs. ... IEEE 802.3az Energy Efficient Ethernet (1000BASE-T and 10GBASE-T).

Copyright © 2015 Intel Corporation. All rights reserved. Intel and the Intel logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

*Other names and brands may be claimed as the property of others.

320117-009US

Driver Support

VMWare ESX*Windows Server 2012 R2Windows Server 2012Microsoft Windows 7*Microsoft Windows Vista* (32 & 64 bit)Microsoft Windows XP* (32 & 64 bit)Microsoft Windows CE*Microsoft Windows NT*Microsoft Windows Server 2003* (32 & 64 bit)Microsoft Windows 2000 Server*Microsoft DOS*Linux* Kernel.org IB treeSUSE Linux Enterprise Server* Red Hat Enterprise Linux* FreeBSD*Solaris*SCO UnixWare* 7.xOpen Unix* 8.0Novell ODI*Novell Netware*

Intel® Advanced Networking ServicesTeaming Initiate a team with up to eight NICs.

Multi-Vendor Teaming Allows teaming with third-party NICs and LOM solutions.

Adapter Fault ToleranceProvides automatic redundancy for the server’s network connection should the primary adapter fail.

Transmit and Receive Load BalancingBalances network traffic across teamed network connections.

802.1q VLAN TaggingAllows teaming in multiple sub-networks by creating virtual adapters.

Link AggregationSupports Intel® Link Aggregation, Fast EtherChannel, Gigabit EtherChannel, and IEEE 802.3ad standards. Continues to balance traffic even if one of the teamed connections loses link.

1115/MBR/MESH/PDF

www.intel.com/ethernet

Intel® ethernet Controllers and PhYs

Page 2: Intel ethernet Controllers and PhYs · 1115/MBR/MESH/PDF  Intel® ethernet Controllers and PhYs. ... IEEE 802.3az Energy Efficient Ethernet (1000BASE-T and 10GBASE-T).

Intel® Ethernet Controllers and PHYs www.intel.com/ethernetProduct Device External Interface Support Host A1:P47 Type Package Size/

Physical PackagePerformance Features Target Applications Management Features Power (Max) Power (Typical) Power (Standby) Operating

TempPower Supply

Order Code Footprint Compatible with:

Recommended for New Designs

Intel® FM10840 1/10/25/40/100GbE Multi-host Controller

KR4, CR4, SR4, KR, CR, SR, SFI, KX, SGMII, 2.5GbE, 25GbE

Four PCI Express* v3.0 (8.0 GT/s) x8/x4/x2/x1 orEight PCI Express* v3.0 (8.0 GT/s) x4/x2/x1

37.5 x 37.5 mm 1435-pin Flip-Chip

Up to 200Gbps of PCIe bandwidth and up to 36-lanes of Ethernet connectivity. Integrated frame processing pipeline that operates up to 960Mpps and includes a 32K 40b TCAM. Two integrated tunneling engines for network virtualization encap/decap at 100Gbps.

Network appliances, high-performance Ethernet adapters, dense rack architectures

Dedicated 1-lane PCIe interface or management through any PCIe interface

40 W 30 W NA 5-85° C 2.5V, 1.0V, 0.85V

EZFM10840 __ Yes

Intel® FM10420 1/10/25/40/100GbE Multi-host Controller

KR4, CR4, SR4, KR, CR, SR, SFI, KX, SGMII, 2.5GbE, 25GbE

Two PCI Express* v3.0 (8.0 GT/s) x8/x4/x2/x1 orFour PCI Express* v3.0 (8.0 GT/s) x4/x2/x1

37.5 x 37.5 mm 1435-pin Flip-Chip

Up to 100Gbps of PCIe bandwidth and up to 8-lanes of Ethernet connectivity. Integrated frame processing pipeline that operates up to 960Mpps and includes a 32K 40b TCAM. Two integrated tunneling engines for network virtualization encap/decap at 100Gbps.

Network appliances, high-performance Ethernet adapters, dense rack architectures

Dedicated 1-lane PCIe interface or management through any PCIe interface

17.5 W 13 W NA 5-85° C 2.5V, 1.0V, 0.85V

EZFM10420 __ Yes

Intel® FM10064 1/10/25/40/100GbE Multi-host Controller

KR4, CR4, SR4, KR, CR, SR, SFI, KX, SGMII, 2.5GbE, 25GbE

NA 37.5 x 37.5 mm 1435-pin Flip-Chip

Up to 36-lanes of Ethernet connectivity. Integrated frame processing pipeline that operates up to 960Mpps and includes a 32K 40b TCAM. Two integrated tunneling engines for network virtualization encap/decap at 100Gbps.

Low radix Ethernet switch, dense rack architectures

Dedicated 1-lane PCIe interface 33 W 25 W NA 5-85° C 2.5V, 1.0V, 0.85V

EZFM10064 __ Yes

Intel® XL710-AM2Intel® XL710-BM2

Dual Port 40GbE (or 4x10 GbE )

KR4, CR4, XLAUI, XLPPI, KR, SFI, XAUI, KX4, KX, SGMII

PCI Express* v3.0 (8.0 GT/s) x8/x4/x2/x1

25x25 mm 576-pin Flip-Chip

1536 queue pairs in the device and 16 per virtual function, 128 VFs for the device, 384 VSI in the device. VXLAN, NVGRE and Geneve stateless offloads, Intel® Ethernet Flow Director, Optimized for Data Plane Developer Kit for small packet performance.

Enterprise servers, blades, embedded systems

NC-SI over RMII Legacy SMBus pass through NC-SI over MCTP over PCIe or over SMBus (DSP0261) NC-SI over MCTP pass through (PCIe & SMBus) shared MAC/IP filtering

6.47 W (2x40 Configuration)

3.82 W (2x40 Configuration)

3.34 W (2x40 Configuration) 0-70° C 3.3 V, 0.85 (VCCD)

FTXL710-AM2FTXL710-BM2

FTXL710-AM2FTXL710-BM2FTXL710-AM1FTXL710-BM1JL82599ENJL82599EBJL82599ES

Yes

Intel® XL710-AM1Intel® XL710-BM1

Single Port 40GbE(or 4x10GbE)

KR4, CR4, XLAUI, XLPPI, KR, SFI, XAUI, KX4, KX, SGMII

PCI Express* v3.0 (8.0 GT/s) x8/x4/x2/x1

25x25 mm 576-pin Flip-Chip

1536 queue pairs in the device and 16 per virtual function, 128 VFs for the device, 384 VSI in the device. VXLAN, NVGRE and Geneve stateless offloads, Intel® Ethernet Flow Director, Optimized for Data Plane Developer Kit for small packet performance.

Enterprise servers, blades, embedded systems

NC-SI over RMII Legacy SMBus pass through NC-SI over MCTP over PCIe or over SMBus (DSP0261) NC-SI over MCTP pass through (PCIe & SMBus) Improved shared MAC/IP filtering

5.92 W (1x40 Configuration)

3.34 W (1x40 Configuration)

2.95 W (1x40 Configuration) 0-70° C 3.3 V, 0.85 (VCCD)

FTXL710-AM1FTXL710-BM1

FTXL710-AM2FTXL710-BM2FTXL710-AM1FTXL710-BM1JL82599ENJL82599EBJL82599ES

Yes

Intel® X710-AM2Intel® X710-BM2

Dual Port 10GbE KR, SFI, XAUI, KX4, KX, SGMII PCI Express* v3.0 (8.0 GT/s) x8/x4/x2/x1

25x25 mm 576-pin Flip-Chip

1536 queue pairs in the device and 16 per virtual function, 128 VFs for the device, 384 VSI in the device. VXLAN, NVGRE and Geneve stateless offloads, Intel® Ethernet Flow Director, Optimized for Data Plane Developer Kit for small packet performance.

Enterprise servers, blades, embedded systems

NC-SI over RMII Legacy SMBus pass through NC-SI over MCTP over PCIe or over SMBus (DSP0261) NC-SI over MCTP pass through (PCIe & SMBus) Improved shared MAC/IP filtering

5.63 W (2x10 Configuration)

3.04 W (2x10 Configuration)

2.77 W (2x10 Configuration) 0-70° C 3.3 V, 0.85 (VCCD)

FTX710-BM2FTX710-BM2

FTXL710-AM2FTXL710-BM2FTXL710-AM1FTXL710-BM1JL82599ENJL82599EBJL82599ES

Yes

Intel® 82599ES Dual Port 10GbE KR, SFI, XAUI, KX4, KX, CX4, BX, SGMII

PCI Express* v2.0 (5.0 GT/s) x8/x4/x2/x1

25x25 mm 576-pin Flip-Chip

128 queue pairs, Receive Side Coalescing (RSC), low latency interrupts, Intel® Ethernet Flow Director, Intel® Virtualization Technology for Connectivity (Intel® VT-c) (VMDq, SR-IOV), FCoE CRC offload, FCoE direct data placement , Optimized for Data Plane Developer Kit for small packet performance.

Enterprise servers, blades, embedded systems

IPMI pass-through via SMBus or NC-SI, iSCSI boot, WoL, PXE remote boot, VLAN filtering

~5.4 W (KR Dual Port)

~5.2 W (KX4 Dual Port)

4.5 W (KX4/KR Dual Port) ~1.3 W (D3 Cold, WoL enabled, 1000 Mb/s) 0-70° C 3.3, 1.2 V JL82599ES JL82599EN Yes

Intel® 82599EB Dual Port 10GbE XAUI, KX4, KX, CX4, BX, SGMII PCI Express* v2.0 (5.0 GT/s) x8/x4/x2/x1

25x25 mm 576-pin Flip-Chip

128 queue pairs, Receive Side Coalescing (RSC), low latency interrupts, Intel® Ethernet Flow Director, Intel® Virtualization Technology for Connectivity (Intel® VT-c) (VMDq, SR-IOV), FCoE CRC offload, FCoE direct data placement.

Enterprise servers, blades, embedded systems

IPMI pass-through via SMBus or NC-SI, iSCSI boot, WoL, PXE remote boot, VLAN filtering

~5.4 W (KR Dual Port)

~5.2 W (KX4 Dual Port)

4.5 W (KX4/KR Dual Port) ~1.3 W (D3 Cold, WoL enabled, 1000 Mb/s) 0-70° C 3.3, 1.2 V JL82599EB __ __

Intel® 82599EN Single Port 10GbE SFI PCI Express* v2.0 (5.0 GT/s) x8/x4/x2/x1

25x25 mm 576-pin Flip-Chip

64 queue pairs, Receive Side Coalescing (RSC), low latency interrupts, Intel® Ethernet Flow Director, Intel® Virtualization Technology for Connectivity (Intel® VT-c) (VMDq, SR-IOV), FCoE CRC offload, FCoE direct data placement, Optimized for Data Plane Developer Kit for small packet performance.

Enterprise servers, blades, embedded systems

Advanced: IPMI pass-through via SMBus or NC-SI, iSCSI boot Standard: WoL, PXE remote boot, VLAN filtering

~4.1 W (KR)

~4.0 W (KX4) “

~3.3 W (KR/KX4) ~1.3 W (D3 Cold, WoL enabled, 1000 Mb/s) 0-70° C 3.3, 1.2 V JL82599EN JL82599ES Yes

Intel® X550-AT2 Dual Port 10GbE 10GBASE-T, 1000BASE-T, 100BASE-TX

PCI Express* v3.0 (8.0 GT/s) x4/x1

17x17 mm 256-pin FCBGA

128 queue pairs, Receive Side Coalescing (RSC), 128 VFs for the device, Intel® Ethernet Flow Director, VXLAN and NVGRE stateless offloads, FCoE CRC offload, FCoE direct data placement, Optimized for Data Plane Developer Kit for small packet performance, IEEE 802.3az Energy Efficient Ethernet (1000BASE-T and 10GBASE-T).

Enterprise servers, entry server, embedded systems

NC-SI over RMII Legacy SMBus pass through NC-SI over MCTP over PCIe or over SMBus (DSP0261) NC-SI over MCTP pass through (PCIe & SMBus) shared MAC/IP filtering

11W (100 m Cable, Active)

9W (30 m Cable, Active)

10 W (100M Cable, Active)8 W (30m Cable, Active) “

~2.6 W (D3 Cold, WoL enabled, 100 Mb/s) 0-55° C 3.3, 2.1, 1.2, 0.83 V

ELX550AT2 ELX550AT Yes

Intel® X550-BT2 Dual Port 10GbE 10GBASE-T, 1000BASE-T, 100BASE-TX

PCI Express* v2.1 (5.0 GT/s) x8/x4/x1

25x25 mm 576-pin Flip-Chip

128 queue pairs, Receive Side Coalescing (RSC), 128 VFs for the device, Intel® Ethernet Flow Director, VXLAN and NVGRE stateless offloads, FCoE CRC offload, FCoE direct data placement, Optimized for Intel® Data Plane Developer Kit for small packet performance, IEEE 802.3az Energy Efficient Ethernet (1000BASE-T and 10GBASE-T).

Enterprise servers, entry server, embedded systems

NC-SI over RMII Legacy SMBus pass through NC-SI over MCTP over PCIe or over SMBus (DSP0261) NC-SI over MCTP pass through (PCIe & SMBus) shared MAC/IP filtering

11W (100 m Cable, Active)

9W (30 m Cable, Active)

10 W (100M Cable, Active)8 W (30m Cable, Active)

~2.6 W (D3 Cold, WoL enabled, 100 Mb/s) 0-55° C 3.3, 2.1, 1.2, 0.83 V

ELX550BT2 NHI350BT2ELX540AT2ELX540BT2

Yes

Intel® X550-AT Single Port 10GbE 10GBASE-T, 1000BASE-T, 100BASE-TX

PCI Express* v3.0 (8.0 GT/s) x4/x1

17x17 mm 256-pin FCBGA

64 queue pairs, Receive Side Coalescing (RSC), 64 VFs for the device, Intel® Ethernet Flow Director, VXLAN and NVGRE stateless offloads, FCoE CRC offload, FCoE direct data placement, Optimized for Data Plane Developer Kit for small packet performance, IEEE 802.3az Energy Efficient Ethernet (1000BASE-T and 10GBASE-T).

Enterprise servers, entry server, workstation, embedded systems

NC-SI over RMII Legacy SMBus pass through NC-SI over MCTP over PCIe or over SMBus (DSP0261) NC-SI over MCTP pass through (PCIe & SMBus) shared MAC/IP filtering

~8 W ~8 W ~2.6 W (D3 Cold, WoL enabled, 100 Mb/s) 0-55° C 3.3, 2.1, 1.2, 0.83 V

ELX550AT ELX550AT2 Yes

Intel® X540-AT2Intel® X540-BT2

Dual Port 10GbE 10GBASE-T, 1000BASE-T, 100BASE-TX

PCI Express* v2.1 (5.0 GT/s) x8/x4/x2/x1

25x25 mm 576-pin Flip-Chip

128 queue pairs, Receive Side Coalescing (RSC), low latency interrupts, Intel® Ethernet Flow Director, Intel® Virtualization Technology for Connectivity (Intel® VT-c) (VMDq, SR-IOV), FCoE CRC offload, FCoE direct data placement.

Enterprise servers, entry server, embedded systems

IPMI pass-through via SMBus or NC-SI, iSCSI boot, WoL, PXE remote boot, VLAN filtering

~12.5 W (X540-AT2)

~14.0 W (X540-BT2)

~11.5 W (X540-AT2)~13.0 W (X540-AT2)

~3 W (X540-AT2 - D3 Cold, WoL enabled, 100 Mb/s)~4 W (X540-BT2 - D3 Cold, WoL enabled, 100 Mb/s)

0-55° C 3.3, 2.5, 1.2, 0.8, 0.67 V

ELX540AT2ELX540BT2

NHI350BT2ELX550BT2ELX540AT2ELX540BT2

Yes

Intel® I350-AM2 Dual Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T, SerDes, SGMII

PCI Express* v.2.1 (5.0 GT/s & 2.5 GT/s) x4/x2/x1

17x17 mm 256-pin FCBGA

8 Tx and 8 Rx queues per port, Receive Side Scaling (RSS), Message Signal Interrupt Extension (MSI-X), UDP, TCP and IP Checksum offloads, UDP and TCP Transmit Segmentation Offload (TSO), SCTP receive and transmit checksum offloads, Stateless offloads (header splitting), jumbo frames (9.5k), Intel® Virtualization Technology for Connectivity (Intel® VT-c) (VMDq, SR-IOV), IEEE 1588 (time sync) / 802.1AS.

Enterprise servers, blades, embedded systems

IPMI pass-through via SMBus or NC-SI, WoL, PXE remote boot, ISCSI boot, VLAN filtering

Intel® I350-AM2~2.5 W (Copper)~ 2.4 W (SerDes)

Intel® I350-AM2~2.1 W (Copper)~1.8 W (SerDes)

~470 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled)

-10-85° C 3.3, 1.8 V NHI350AM2

NHI350AM4

NHI350AM4NH82580EBNH82580DB

Yes

Intel® I350-AM4 Quad Port 1000BASE-T, 100BASE-TX, 10BASE-T, SerDes, SGMII

PCI Express* v.2.1 (5.0 GT/s & 2.5 GT/s) x4/x2/x1

17x17 mm 256-pin FCBGA

9 Tx and 8 Rx queues per port, Receive Side Scaling (RSS), Message Signal Interrupt Extension (MSI-X), UDP, TCP and IP Checksum offloads, UDP and TCP Transmit Segmentation Offload (TSO), SCTP receive and transmit checksum offloads, Stateless offloads (hea splitting), jumbo frames (9.5k), Intel® Virtualization Technology for Connectivity (Intel® VT-c) (VMDq, SR-IOV), IEEE 1588 (time sync) / 802.1AS.

Enterprise servers, blades, embedded systems

IPMI pass-through via SMBus or NC-SI, WoL, PXE remote boot, ISCSI boot, VLAN filtering

Intel® I350-AM4~3.8 W (Copper)~2.9 W (SerDes)

Intel® I350-AM4~3.4 W (Copper)~2.3 W (SerDes)

~470 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled)

-10-85° C 3.3, 1.8 V NHI350BT2 NHI350AM2NH82580EBNH82580DB

Yes

Intel® I350-BT2 Quad Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T, SerDes, SGMII

PCI Express* v.2.1 (5.0 GT/s & 2.5 GT/s) x4/x2/x1

25x25 mm 576-pin Flip-Chip

8 Tx and 8 Rx queues per port, Receive Side Scaling (RSS), Message Signal Interrupt Extension (MSI-X), UDP, TCP and IP Checksum offloads, UDP and TCP Transmit Segmentation Offload (TSO), SCTP receive and transmit checksum offloads, Stateless offloads (header splitting), jumbo frames (9.5k), Intel® Virtualization Technology for Connectivity (Intel® VT-c) (VMDq, SR-IOV), IEEE 1588 (time sync) / 802.1AS.

Enterprise servers, blades, embedded systems

IPMI pass-through via SMBus or NC-SI, WoL, PXE remote boot, ISCSI boot, VLAN filtering

Intel® I350-BT2~2.5 W (Copper)

Intel® i350-BT2~2.1 W (Copper)

~470 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled)

-10-85° C 3.3, 1.8 V NH82580DB

NH82580EB

JLX540AT2 Yes

Intel® 82580DB Dual Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T, SerDes, SGMII

PCI Express* v.2.0 (5.0 GT/s & 2.5 GT/s) x4/x2/x1

17x17 mm 256-pin FCBGA

8 Tx and 8 Rx queues per port, Receive Side Scaling (RSS), Message Signal Interrupt Extension (MSI-X), UDP, TCP and IP Checksum offloads, UDP and TCP Transmit Segmentation Offload (TSO), SCTP receive and transmit checksum offloads, Stateless offloads (header splitting), jumbo frames (9.5k), Intel® Virtualization Technology for Connectivity (Intel® VT-c) (VMDq), IEEE 1588 (time sync) / 802.1AS.

Enterprise servers, blades, embedded systems

IPMI pass-through via SMBus or NC-SI, WoL, PXE remote boot, ISCSI boot, VLAN filtering

Intel® 82580DB~2.6 W (Copper)~2.0 W (SerDes)

Intel® 82580DB~2.1 W (Copper)~1.4 W (SerDes)

~690 mW (D3 cold, WoL enabled, 100 Mb/s) -10-85° C 3.3, 1.8 V JL82576EB NHI350AM2NHI350AM4NH82580EB

Intel® 82580EB Quad Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T, SerDes, SGMII

PCI Express* v.2.0 (5.0 GT/s & 2.5 GT/s) x4/x2/x1

17x17 mm 256-pin FCBGA

16 Rx and 16 Tx queues per port, Intel® QuickData Technology, MSI-X, Receive Side Scaling (RSS), checksum and segmentation offload, header splitting/replication, low latency interrupts, jumbo frames (9.5k), Intel® Virtualization Technology for Connectivity (Intel® VT-c) (VMDq, SR-IOV), IEEE 1588 (time sync) / 802.1AS, Security (IPsec offload, LinkSec3).

Enterprise servers, blades, embedded systems

IPMI pass-through via SMBus or NC-SI, WoL, PXE remote boot, ISCSI boot, VLAN filtering

Intel® 82580EB~3.9 W (Copper)~2.6 W (SerDes)

Intel® 82580EB~3.3 W (Copper)~2.0 W (SerDes)

~690 mW (D3 cold, WoL enabled, 100 Mb/s) -10-85° C 3.3, 1.8 V JL82575EB NHI350AM2NHI350AM4NH82580DB

Intel® 82576EB Single Port GbEDual Port GbE

1000BASE-T, 100BASE-TX, 10BASE-T, SerDes, SGMII

PCI Express* v2.0 (2.5 GT/s) x4/x2/x1

25x25 mm 576-pin Flip-Chip

4 Tx and 4 Rx queues per port, Receive Side Scaling (RSS), Message Signal Interrupt Extension (MSI-X), UDP, TCP and IP Checksum offloads, UDP and TCP Transmit Segmentation Offload (TSO), SCTP receive and transmit checksum offloads, Stateless offloads (header splitting), jumbo frames (9.5k), IEEE 802.3az Energy Efficient Ethernet, IEEE 1588 (time sync) / 802.1AS, IEEE 802.1Qav Audio-Video Bridging.

Enterprise servers, blades, embedded systems

IPMI pass-through via SMBus or NC-SI, WoL, PXE remote boot, ISCSI boot, VLAN filtering

~2.8W (Copper) ~ 900 mW (SerDes)

~2.4 W (Copper) ~700 mW (SerDes)

~790 mW (D3 cold, WoL enabled, 100 Mb/s) 0-55° C 3.3, 1.8, 1.0 V HL82572EI

HL82571EB

JL82575EB —

Intel® 82571EB Dual Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T, SerDes

PCI Express* x4/x2/x1 17x17 mm 256-pin FCBGA

2 Tx and 2 Rx queues per port, Receive Side Scaling (RSS), Message Signal Interrupt Extension (MSI-X), UDP, TCP and IP Checksum offloads, UDP and TCP Transmit Segmentation Offload (TSO), SCTP receive and transmit checksum offloads, Stateless offloads (header splitting), jumbo frames (9.5k), IEEE 802.3az Energy Efficient Ethernet, IEEE 1588 (time sync) / 802.1AS.

Enterprise servers, blades, embedded systems

IPMI pass-through via SMBus or FML, WoL, PXE remote boot, ASF 2.0, iSCSI boot, serial over LAN, VLAN filtering

~3.4 W (Copper),

~1.8 W (SerDes)

~2.8 W (Copper), ~1.2 W (SerDes)

780 mW (D3 cold, WoL enabled, 100 Mb/s) for 82571EB 0-70° C 3.3, 1.8, 1.1 V WG82574L

WG82574IT

__ —

Intel® I210-ATIntel® I210-IT

Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* v2.1 x1 (2.5 GT/S)

9x9 mm 64-pin QFN

4 Tx and 4 Rx queues per port, Receive Side Scaling (RSS), Message Signal Interrupt Extension (MSI-X), UDP, TCP and IP Checksum offloads, UDP and TCP Transmit Segmentation Offload (TSO), SCTP receive and transmit checksum offloads, Stateless offloads (header splitting), jumbo frames (9.5k), IEEE 1588 (time sync) / 802.1AS, IEEE 802.1Qav Audio-Video Bridging.

Desktop, Server and Embedded systems

IPMI pass-through via SMBus or NC-SI, MCTP protocol over SMBus, MCTP protocol over PCIe, WoL, PXE remote boot, ISCSI boot, VLAN filtering

~740 mW (I210-AT) ~800 mW (I210-IT)

~630 mW ~126 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled)

0-70° C -40-85° C

3.3 V WG82583V WGI211AT Yes

Intel® I210-IS Single Port GbE SerDes, SGMII PCI Express* v2.1 x1 (2.5 GT/S)

9x9 mm 64-pin QFN

2 Tx and 2 Rx queues per port, Receive Side Scaling (RSS), Message Signal Interrupt Extension (MSI-X), UDP, TCP and IP Checksum offloads, UDP and TCP Transmit Segmentation Offload (TSO), SCTP receive and transmit checksum offloads, Stateless offloads (header splitting), jumbo frames (9.5k), IEEE 1588 (time sync) / 802.1AS.

Server and Embedded systems IPMI pass-through via SMBus or NC-SI, MCTP protocol over SMBus, MCTP protocol over PCIe, WoL, PXE remote boot, VLAN filtering

~580 mW ~363 mW (SerDes/SGMII) ~126 mW (D3 cold, WoL enabled, 100 Mb/s,

EEE Enabled)

-40-85° C 3.3 V WGI211AT — Yes

Intel® I211-AT Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* v2.1 x1 (2.5 GT/S)

9x9 mm 64-pin QFN

2 Tx and 2 Rx queues per port, Receive Side Scaling (RSS), Message Signal Interrupt Extension (MSI-X), UDP, TCP and IP Checksum offloads, UDP and TCP Transmit Segmentation Offload (TSO), SCTP receive and transmit checksum offloads, Stateless offloads (header splitting), jumbo frames (9.5k), IEEE 802.3az Energy Efficient Ethernet, IEEE 1588 (time sync) / 802.1AS.

Desktop and Embedded systems WoL, PXE remote boot ~740 mW ~630 mW ~126 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled)

0-70° C 3.3 V WG82583V WGI210AT Yes

Intel® 82574LIntel® 82574IT

Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* v1.1 x1 9x9 mm 64-pin QFN

2 Tx and 2 Rx queues, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, VLAN support, 9k jumbo frames, RSS, MSI, MSI-X.

Server and embedded systems IPMI pass-through via SMBus or NC-SI, WoL, PXE remote boot, ISCSI boot, VLAN filtering

~727 mW ~727 mW 188 mW (D3 cold, WoL enabled, 100 Mb/s) 0-85° C -40-85° C

3.3 V Yes WG82583V —

Intel® 82583V Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* v1.1 x1 9x9 mm 64-pin QFN

TCP segmentation offload, TCP, UDP, IPv4 checksum offload, VLAN support, 9k jumbo frames. Desktop and Embedded systems PXE remote boot ~727 mW ~727 mW 188 mW (D3 cold, WoL enabled, 100 Mb/s) 0-85° C 3.3 V WG82579LM WG82583V —

Intel® X557-AT4 Quad Port 10GbE 10GBASE-T, 1000BASE-T, 100BASE-TX

KR, SGMII 19x19 mm 324-pin FCBGA

IEEE 802.3az Energy Efficient Ethernet (1000BASE-T and 10GBASE-T), MDI/MDI-X with Automatic Polarity Correction.

Entry Server, Workstation, Desktop, Mobile and embedded applications

N/A ~13.6 W ~12 W (30m cable) ~5.4 W 0-70° C 2.5, 2.1, 1.2, 0.83 V

EZX557AT4 — Yes

Intel® X557-AT2 Dual Port 10GbE 10GBASE-T, 1000BASE-T, 100BASE-TX

KR, SGMII 19x19 mm 324-pin FCBGA

IEEE 802.3az Energy Efficient Ethernet (1000BASE-T and 10GBASE-T), MDI/MDI-X with Automatic Polarity Correction.

Entry Server, Workstation, Desktop, Mobile and embedded applications

N/A ~6.8 W ~6 W (30m cable) ~2.6 W 0-70° C 2.5, 2.1, 1.2, 0.83 V

EZX557AT2 EZX557AT Yes

Intel® X557-AT Single Port 10GbE 10GBASE-T, 1000BASE-T, 100BASE-TX

KR, SGMII 25x25 mm 576-pin FCBGA

IEEE 802.3az Energy Efficient Ethernet (1000BASE-T and 10GBASE-T), MDI/MDI-X with Automatic Polarity Correction.

Enterprise Server, Workstation, Embedded applications

N/A ~3.4 W ~3 W (30m cable) ~1.3 W 0-70° C 2.5, 2.1, 1.2, 0.83 V

EZX557AT EZX557AT2 Yes

Intel® I219-LM Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 6x6 mm 48-pin QFN 2Tx and 2 Rx queues, IEEE 802.3az Energy Efficient Ethernet, IEEE 1588 (time sync) / 802.1AS. Up to 32 programmable filters, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, jumbo frames (9k).

Entry Server, Workstation, Desktop, Mobile and embedded applications

Intel® vPro™ technology, WoL, PXE Boot, VLAN filtering 542 mW 542 mW 51 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled)0.13 mW Cable Disconnect ULP Mode

0-85° C 3.3 V WGI219LM WGI219V Yes

Intel® I219-V Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 6x6 mm 48-pin QFN 2Tx and 2 Rx queues, IEEE 802.3az Energy Efficient Ethernet, IEEE 1588 (time sync) / 802.1AS. Up to 32 programmable filters, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, jumbo frames (9k).

Desktop, Mobile and embedded applications

WoL, PXE Boot, and VLAN filtering 542 mW 542 mW 51 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled)0.13mw Cable Disconnect ULP Mode

0-85° C 3.3 V WGI219V WGI219LM Yes

Intel® I218-LM Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 6x6 mm 48-pin QFN 2Tx and 2 Rx queues, IEEE 802.3az Energy Efficient Ethernet, IEEE 1588 (time sync) / 802.1AS. Up to 16 programmable filters, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, jumbo frames (9k).

Entry Server, Workstation, Desktop, Mobile and embedded applications

Intel® vPro™ technology, WoL, PXE Boot, VLAN filtering ~ 630 mW ~ 620 mW 51 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled)0.13 mW Cable Disconnect ULP Mode

0-85° C 3.3 V WGI2189LM WGI218V Yes

Intel® I218-V Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 6x6 mm 48-pin QFN 2Tx and 2 Rx queues, IEEE 802.3az Energy Efficient Ethernet, IEEE 1588 (time sync) / 802.1AS. Up to 16 programmable filters, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, jumbo frames (9k).

Desktop, Mobile and embedded applications

WoL, PXE Boot, and VLAN filtering ~ 630 mW ~ 620 mW 51 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled)0.13 mW Cable Disconnect ULP Mode

0-85° C 3.3 V WGI218V WGI2189LM Yes

Intel® I217-LM Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 6x6 mm 48-pin QFN 2Tx and 2 Rx queues, IEEE 802.3az Energy Efficient Ethernet, IEEE 1588 (time sync) / 802.1AS. Up to 16 programmable filters, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, jumbo frames (9k).

Entry Server, Workstation, Desktop, Mobile and embedded applications

Intel® vPro™ technology, WoL, PXE Boot, VLAN filtering 535 mW 535 mW ~43 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled) 0-85° C 3.3 V WGI217LM WGI217V Yes

Intel® I217-V Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 6x6 mm 48-pin QFN 2Tx and 2 Rx queues, IEEE 802.3az Energy Efficient Ethernet, IEEE 1588 (time sync) / 802.1AS. Up to 16 programmable filters, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, jumbo frames (9k).

Desktop, Mobile and embedded applications

WoL, PXE Boot, and VLAN filtering 535 mW 535 mW ~43 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled) 0-85° C 3.3 V WGI217V WGI217LM Yes

Intel® 82579LM Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 6x6 mm 48-pin QFN 2 Tx and 2 Rx queues, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, jumbo frames (9k).

Mobile and embedded applications Intel® vPro™ technology, WoL, PXE Boot, VLAN filtering ~ 630 mW ~ 620 mW ~176 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled) 0-85° C 3.3, 1.05 V WG82579LM WG82579V __

Intel® 82579V Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 6x6 mm 48-pin QFN 2Tx and 2 Rx queues, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, jumbo frames (9k).

Mobile and embedded applications WoL, PXE Boot, and VLAN filtering ~ 630 mW ~ 620 mW ~176 mW (D3 cold, WoL enabled, 100 Mb/s, EEE Enabled) 0-85° C 3.3, 1.05 V WG82579V WG82579LM __

Intel® 82577LM Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 6x6 mm 48-pin QFN 2Tx and 2 Rx queues, TCP segmentation offload, TCP, UDP, IPv4 checksum offload, interrupt moderation, jumbo frames (4k).

Mobile and embedded applications Intel® vPro™ technology, WoL, PXE Boot, and VLAN filtering ~ 730 mW ~ 707 mW ~251 mW (D3 cold, WoL enabled, 100 Mb/s) 0-85° C 3.3, 1.05 V WG82577LM — __

Intel® 82567LM Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 8x8 mm 56-pin QFN 2 Rx and 2 Tx queues, jumbo frames (9k), RSS, on I/O Controller Hub 9 Mobile (ICH9M), ICH9, ICH10 chipsets. Enterprise clients, consumer, embedded systems

Intel® Active Management Technology, WoL, PXE remote boot, ASF 2.0

~680 mW ~670mW ~140 mW (D3 cold, WoL enabled, 10 Mb/s) 0-85° C 3.3, 1.8, 1.05 V WG82567LM WG82567V __

Intel® 82567V Single Port GbE 1000BASE-T, 100BASE-TX, 10BASE-T

PCI Express* 8x8 mm 56-pin QFN On I/O Controller Hub 8 Mobile (ICH8M), ICH9M, ICH9, ICH10 chipsets. Enterprise clients, consumer, embedded systems

WoL, PXE remote boot, ASF 2.0 ~680 mW ~670 mW ~140 mW (D3 cold, WoL enabled, 10 Mb/s) 0-85° C 3.3, 1.8, 1.05 V WG82567V WG82567LM __

All products are RoHS compliant. All products are compatible with all major operating systems. 1 0-70° C with thermal management 2 Halogen-free 3 LinkSec enabled. Functionality available when the ecosystem is ready to support this new technology.

10/100/1000 MAC/PHY Controllers

10/100/1000 PHY Connections

10/25/40/100 GbE Multi-host Controllers

10/40 GbE MAC/PHY Controllers