Integrated Access Controller Installation ManualIntegrated Access Controller Installation Manual
LED1 2 3
4 5 6
7 8 9
0 #
3000
ANSON Technology Co., Ltd
Product ConnectionProduct Connection
Installation ManualInstallation Manual
Product ManualProduct Manual
Product MaintenanceProduct Maintenance
Live Safely and Conveniently
Function DebuggingFunction Debugging
ASI-8930ASI-8920
ASI-8910
Anson Integrated Access Control Series: ASI-8910, ASI-8920, ASI-8930
Anson Integrated Access Control is characterized by its elegant design and convenient application and installation, which is especially suitable for office buildings and shops. The device is equipped with built-in reader and can work both as controller and reader.
Anson Integrated Access control should be installed indoor. Please consider water-proof facility in case outdoor application is needed.
For detailed information, please refer to Product Manual and Wiring Diagram. Please make sure installation is correctly completed before turn on the power. When connect any external device, please turn off the power. This manual is only a general instruction and all products mentioned in this manual are Anson products.
Live Safely and Conveniently
Product Manual
Features
Operation Instruction
Notice
Product Series
The exterior design of ASI-8920\8930 is protected and patented in P. R. China.
ASI-8910
117
117
21
Working Voltage:DC9-15VWorking Current:≤70mAUnlock Current: ≤3000mAReading Distance: 3-10cmCard Type: ID card
orking Temperature: -15 ~55Card Capacity: 800pcs Input Interface: 1pcs exit button, 1pcs door magnetOutput Interface: 1pcs lock control port(normal open, normal close)
W ℃ ℃
Product Parameters
Product Size
AS
I-89
10
AS
I-89
10
Product Manual
Live Safely and Conveniently
The SideThe Back
The Front
Wire Hole
Fixing Hole
Self-trapping Screw
Rear Cover
Rubber Plug
AS
I-89
10
AS
I-89
10
Installatioin ManualInstallatioin Manual
1. Uncover the back from the bottom 2. Put the back cover against wall and screw tight the bolts
3. Ensure power cable is ready before putthe system on,
4. Screw bolt from bottom
Live Safely and Conveniently
GND +12V COM NO NC GND SW BELL BELL
Door BellExit ButtonEM LockPower
ASI-8910 Interface
GND +12V COM NO NC GND SW BELL BELL
Po
we
r In
terf
ace
ASI-8910 Interface
+12V
GND
Connect with Power
GND +12V COM NO NC GND SW BELL BELL
+12V
GND
V+ V- NOCOM NC
Connect with EM Lock
+-
GND +12V COM NO NC GND SW BELL BELL
+1
2V
GN
D
Connect with Electric Lock
Fail-safe
Fail-secure
AS
I-89
10
AS
I-89
10
Connect with Electric Bolt
GND +12V COM NO NC GND SW BELL BELL
+12V Red
GND Black
SIGNAL
SIGNAL
Door Magnet
+12V
GND
Product Connection Product Connection
ASI-8910 Interface
Po
we
r In
terf
ace
ASI-8910 Interface ASI-8910 Interface
Po
we
r Inte
rface
Power Interface
Electric Bolt
Iron Core Cover Plate
Live Safely and Conveniently
GND +12V COM NO NC GND SW BELL BELL
Connect with Barrier
B
arr
ier
Inte
rfa
ce
(E
lectr
ic L
eve
l Sig
na
l)
Common end
Open
Close
Stop
Connect with Automatic Door
GND +12V COM NO NC GND SW BELL BELL
COM1
COM2
Exit Button
GND +12V COM NO NC GND SW BELL BELLGND +12V COM NO NC GND SW BELL BELL GND +12V COM NO NC GND SW BELL BELL
Connect with Door Bell
For this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, The opening time depends on the door-open delay time. It is recommended to install ultra-red and ground sensor for protection.
Active Boorbell
Notice: Definition of product interface should be in accordance with the real product. For any inconsistence, please contact with us..
AS
I-89
10
AS
I-89
10
Product Connection Product Connection
ASI-8910 Interface ASI-8910 Interface
ASI-8910 Interface ASI-8910 Interface A
uto
ma
tic
Do
or
Inte
rfa
ce
(
Sw
itch
Sig
na
l)
Live Safely and Conveniently
The automatic door is open when COM1-COM2 is short circuit.
CARD
Invalid Card: If the reader sounds twice after the card is presented to the reading area for one second, the card is invalid.Valid Card: If after the card is presented to the reading area for 0.5 seconds, the reader sounds once, green lights on and delay acts, then the card is valid.
3-10CM
As shown in the picture, when the button is pressed, the device sounds once and the relay status changes once.
ASI-8910
Dial *Input the administrator password
MODE light is on, program mode
Dial 2 add one card
Adjust the multimeter to When the power is on, in normal state, COM-NC is short circuit, while COM-NO is open circuit. When present the valid card or press the exit button, COM-NC turns into open circuit.
,
Read cardInput 4-digit card serial number
Dial # to exit from programming mode Complete the setting
GND +12V GND SW COM NO NC BELL BELL
ASI-8910 Interface
A
COMNC
NOCOM
NC
NO
Normal State Door-open State
AS
I-89
10
AS
I-89
10
GND +12V COM NO NC GND SW BELL BELL
Function DebuggingFunction Debugging
Test Reading Card
Test the Keypad
Test Output
Test Input
Live Safely and Conveniently
1. If there is no sound when card is presented to the reading area, the reading function maybe damaged.
2. If there is no sound when press the keys, the keypad maybe damaged.
3. When add card, if the device exits program mode automatically, the memory maybe damaged.
4. If valid card is read and OK light is on, while relay does not act, the lock control may malfunction.
5. If relay keeps on in open state, buzzer keeps buzzing, and SW-GND is short or lower than , the keys maybe damaged.
6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged.
7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can not work properly.
8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages.
The life of products is related to application environment and application method. Please carefully follow the product manual and installation manual.
In case of any problem, please contact with our technical support instead of self- repairment. Please keep the original state of the products when sending back for repairment. Please notify us if you have any special demand, and we will feedback within 48 hours.
3.5V
AS
I-89
10
AS
I-89
10
Product Maintenance Product Maintenance
Live Safely and Conveniently
Common Question
安全生活● 方便生活
AS
I-89
20
AS
I-89
20
1 2 3
4 5 6
7 8 9
0 #
150mm
88
mm
30mm
Product Manual
The Front The Side
485 232
GND12VDAT0DAT1SW
GNDMenC1
BELLBELL
RXTX
GND485+485-
2C2NO1NO
1C1NC
GND
Fixing Hole
Jumper
The Back
Fixing Hole
Fixing Hole
Working Voltage:DC9-15VStatic Current:≤110mAReading Distance: 5-10cmCard Type: ID cardWorking Temperature: -15℃~55℃Card Capacity: 3000pcs Input Interface: 1pcs exit button, 1pcs door magnetOutput Interface: 1pcs lock control port (normal open, normal close), 1pcs door magnet alarm output port (normal close) Communication Mode:RS232/RS485Reader Interface: Wiegand 26
Product Parameters
AS
I-89
20
AS
I-89
20
1. Remove the two keys first.
Installation ManualInstallation Manual
2. Unfasten the two screws.
Push up the back cover to open
First open the lower part of backcover for around 1cm. Please note that open too wide may lead to damage to the device.
3. Open the back cover and connect the device according to the wiring diagram.
4. Fix the backcover on the wallReassemble the device. (according
to 1, 2 and 3 in reversed order.
Live Safely and Conveniently
AS
I-89
20
AS
I-89
20
485 232
GND12VDAT0DAT1SW
GNDMenC1
BELLBELL
RXTX
GND485+485-
2C2NO1NO
1C1NC
GND
485 232
GND
12V
DAT0
DAT1
SW
GND
MenC1
BELL
BELL
RX
TX
GND
485+
485-
2C
2NO
1NO
1C
1NC
GND
Power Interface
ReaderInterface
Exit Button Interface
RS232Interface
Door Magnet Alarm OutputInterface
Lock Control Interface
Door Magnet Interface
Door bellInterface
RS485Interface
ASI-8920 Interface
Product Connection Product Connection
Live Safely and Conveniently
Connect with Electric Bolt
Po
we
r In
terf
ace
ASI-8920 Interface
+12V
GND
Connect with Power
+12V
GND
V+ V- NOCOM NC
Connect with EM Lock
+-
+1
2V
GN
D
Fail-safe
Fail-secure
+12V 红 GND 黑 SIGNAL SIGNAL
+12V
GND
GND12VDAT0DAT1SW
GNDMenC1
BELLBELL
RXTX
GND485+485-
2C2NO1NO
1C1NC
GND
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
*Valid state:door magnet is normal open.
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
*Valid state:door magnet is normal open.
ASI-8920 Interface
Po
we
r In
terf
ace
ASI-8920 Interface
ASI-8920 Interface
Power InterfaceConnect with Electric Lock
Electric Bolt
Iron Core Cover Plate
Door Magnet
Po
we
r Inte
rface
AS
I-89
20
AS
I-89
20
COM1
COM2
Exit Button
For this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, The opening time depends on the door-open delay time. It is recommended to install ultra-red and ground sensor for protection.
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
+1
2V
GN
D
+-
接读卡器
2620
1 2 3
4 5 6
7 8 9
* 0 #
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
BlackRedGreenWhite
ASI-8920 Interface ASI-8920 Interface
B
arr
ier
Inte
rfa
ce
(E
lectr
ic L
eve
l S
ign
al)
Common end
Stop
Close
Open
A
uto
ma
tic
Do
or
Inte
rfa
ce
(
Sw
itch
Sig
na
l)
The automatic door is open when COM1-COM2 is short circuit.
Connect with Automatic DoorConnect with Barrier
ASI-8920 Interface ASI-8920 Interface
Active Boorbell
Connect with Door Bell
Power Interface
ASI-8920 Interface
ASI-8920 Interface
Connect with Alarm Device Connect with Reader
Live Safely and Conveniently
Product ConnectionProduct Connection
Alarm Light
AS
I-89
20
AS
I-89
20
Connect with RS485
For 485 communication, please follow the diagram for connection and no other connection mode should be used.
Converter48
5+
48
5-
12345
DB9-Hole
ComputerInterface
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
12345
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
RS232
48
5 2
32
ASI-8920 Interface
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
RS232\TCP/IP
48
5 2
32
Rj45
ASV-TCP/IPDC9~30V
232
485
Rs232
9~30V+
9~30V-
485+
485-
Rs485
12
34
5
DB9-Hole
Rs232Connect with PC or Router
ASI-8920 Interface
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
RS485
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
PWD
RxD
TxD
RS
48
5
RS
23
2RS485-RS232Convertor
Co
mp
ute
rIn
terf
ace
T/R+T/R-GND
48
5 2
32
ASI-8920 Interface
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
48
5 2
32
Rj45
ASV-TCP/IPDC9~30V
232
485
Rs232
9~30V+
9~30V-
485+
485-
Rs485
Rs485
RS485\TCP/IP
Connect with PC or Router
ASI-8920 Interface
Live Safely and Conveniently
Product ConnectionProduct Connection
1 2 3
4 5 6
7 8 9
0 #
A
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
Function Debugging Function Debugging
AS
I-89
20
AS
I-89
20
Invalid Card: If the reader sounds twice after the card is presented to the reading area for one second, the card is invalid.Valid Card: If after the card is presented to the reading area for 0.5 seconds, the reader sounds once, green lights on and delay acts, then the card is valid.
When the buzzer sounds once,Dial “*”, the orange light flashes; Input“000000”, the orange light turns on and device enters program mode. This means the keypad is OK.
Adjust the multimeter to , When the power is on, in normal state, 1C-1NC is short circuit, while 1C-1NO is open circuit. When present the valid card or press the exit button, 1C-1NC turns into open circuit, while 1C-1NO is short circuit.
1C1NC
1NO1C
1NC
1NO
Normal State Door-open State
Test Reading Card
Test the Keypad
Test Output
Test Input
If valid default input is normal open, no input available for the device when input signal is open-circuit; while input available when input signal is close-circuit. The status reversed when valid default input is normal close.The user can decide the type of default input setup in the software. 8920 has two input interfaces: SW-GND is button input; MenCi-GND is door magnet input. Both of them can be changed in “channel setup”.
ASI-8920 Interface
ASI-8920 Interface
Live Safely and Conveniently
Function DebuggingFunction Debugging
AS
I-89
20
AS
I-89
20
After the exterior device is connected with ASI-8920, please select Tools---Card Register in the software program. Then, select the exterior device and start to read the card. If you can find the card number in the list, it means the exterior device works correctly.
Connect with Exterior Identification Device
1. Select the device
2.Start to read card
Test the Communication
Rs485
ASI-892 has two kinds of communication modes: RS232 and Rs485. User can chose the communication mode by setting up the jumper. ASI-8920 can connect with PC serial port, and one serial port only connects with one ASI-8920. RS485 signal should be converted to Rs232 signal before it can communicate with PC. RS485 can connect with multiple devices. After ASI-8920 is connected with PC, user can detect ASI-8920 address by detecting serial port (please refer to the user manual to setup the address). If”connected” is displayed, the communication is ok. User can get version and model number of ASI-8920 by inputting the address and clicking Auto Detect.
Setup the Jumper
Rs232
Test the time of ASI-8920
Time adjustment is shown in the picture on the left. The time of controller should be in consistent with PC. User can get updated time for controller by press“Refresh”. If controller time is incorrect, card record may get lost, validity of card-read is in doubt, and moreover, valid card may turn into be invalid.
PC time should be in consistent with controller time; otherwise the reader may not work properly.*
3. Get the card number
Live Safely and Conveniently
AS
I-89
20
AS
I-89
20
Product Maintenance Product Maintenance
Urgent Maintenance:1. When the exterior reader can not read the cards, please
test the voltage of DATA0—GND and DATA1---GND. If the
voltage is less than 3.5V, please weld TVS2, TVS3.2. When door magnet input fails, please test the voltage between Menci and GND. If the voltage is less than 3.5V, please weld TVS5.3. When exit button input fails, please test the voltage between SW and GND. If the voltage is less than 3.5V, please weld TVS4.
PCB
Common Question1. If there is no sound when card is presented to the reading area, the reading function maybe damaged.2. If there is no sound when press the keys, the keypad maybe damaged.3. When add card, if the device exits program mode automatically, the memory maybe damaged.4. If valid card is read and OK light is on, while relay does not act, the lock control may malfunction.5. If relay keeps on in open state, buzzer keeps buzzing, and SW-GND is short or lower than , the keys maybe damaged.6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged.7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can not work properly.8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages.
The life of products is related to application environment and application method. Please carefully follow the product manual and installation manual.
In case of any problem, please contact with our technical support instead of self- repairment. Please keep the original state of the products when sending back for repairment. Please notify us if you have any special demand, and we will feedback within 48 hours.
3.5V
Live Safely and Conveniently
AS
I-89
30
AS
I-89
30
1 2 3
4 5 6
7 8 9
0 #
150mm
88mm
30mm
设备参数
Product Manual
485 232
GND12VDAT0DAT1SW
GNDMenC1
BELLBELL
RXTX
GND485+485-
2C2NO1NO
1C1NC
GND
Fixing Hole
Jumper
The Back
Fixing Hole
Fixing Hole
The SideThe Front
Working Voltage:DC9-15VStatic Current:≤120mAReading Distance: 5-10cmCard Type: ID cardWorking Temperature: -15℃~55℃Card Capacity: 3000pcs Input Interface: 1pcs exit button, 1pcs door magnetOutput Interface: 1pcs lock control port (normal open, normal close), 1pcs door magnet alarm output port (normal close) Communication Mode:RS232/RS485Reader Interface: Wiegand 26
Product Parameters
Live Safely and Conveniently
AS
I-89
30
AS
I-89
30
Installation ManualInstallation Manual
Live Safely and Conveniently
1. Remove the two keys first. 2. Unfasten the two screws.
Push up the back cover to open
First open the lower part of backcover for around 1cm. Please note that open too wide may lead to damage to the device.
3. Open the back cover and connect the device according to the wiring diagram.
4. Fix the backcover on the wallReassemble the device. (according
to 1, 2 and 3 in reversed order.
485 232
GND12VDAT0DAT1SW
GNDMenC1
BELLBELL
RXTX
GND485+485-
2C2NO1NO
1C1NC
GND
485 232
GND
12V
DAT0
DAT1
SW
GND
MenC1
BELL
BELL
RX
TX
GND
485+
485-
2C
2NO
1NO
1C
1NC
GND
Power Interface
ReaderInterface
Exit Button Interface
RS232Interface
Door Magnet Alarm OutputInterface
Lock Control Interface
Door Magnet Interface
Door bellInterface
RS485Interface
ASI-8930 Interface AS
I-89
30
AS
I-89
30
Connect with Electric Bolt
Po
we
r In
terf
ace
ASI-8930 Interface
+12V
GND
Connect with Power
+12V
GND
V+ V- NOCOM NC
Connect with EM Lock
+-
+1
2V
GN
D
Fail-safe
Fail-secure
+12V 红 GND 黑 SIGNAL SIGNAL
+12V
GND
GND12VDAT0DAT1SW
GNDMenC1
BELLBELL
RXTX
GND485+485-
2C2NO1NO
1C1NC
GND
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
*Valid state:door magnet is normal open.
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
*Valid state:door magnet is normal open.
ASI-8930 Interface
Po
we
r In
terf
ace
ASI-8930 Interface
ASI-8930 Interface
Power InterfaceConnect with Electric Lock
Electric Bolt
Iron Core Cover Plate
Door Magnet
Po
we
r Inte
rface
Live Safely and Conveniently
Product ConnectionProduct Connection
AS
I-89
30
AS
I-89
30
COM1
COM2
Exit Button
For this type of connection, the barrier switch is closed in normal status. When user presents card or presses the exit button, the barrier will be opened, The opening time depends on the door-open delay time. It is recommended to install ultra-red and ground sensor for protection.
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
+1
2V
GN
D
+-
接读卡器
2620
1 2 3
4 5 6
7 8 9
* 0 #
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
BlackRedGreenWhite
ASI-8930 Interface ASI-8930 Interface
B
arr
ier
Inte
rfa
ce
(E
lectr
ic L
eve
l S
ign
al)
Common end
Stop
Close
Open
A
uto
ma
tic
Do
or
Inte
rfa
ce
(
Sw
itch
Sig
na
l)
The automatic door is open when COM1-COM2 is short circuit.
Connect with Automatic DoorConnect with Barrier
ASI-8930 Interface ASI-8930 Interface
Active Boorbell
Connect with Door Bell
Power Interface
ASI-8930 Interface
ASI-8930 Interface
Connect with Alarm Device Connect with Reader
Live Safely and Conveniently
Alarm Light
Product ConnectionProduct Connection
安全生活● 方便生活
AS
I-89
30
AS
I-89
30
Connect with RS485
For 485 communication, please follow the diagram for connection and no other connection mode should be used.
Converter48
5+
48
5-
12345
DB9-Hole
ComputerInterface
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
12345
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
RS232
48
5 2
32
ASI-8930 Interface
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
RS232\TCP/IP
48
5 2
32
Rj45
ASV-TCP/IPDC9~30V
232
485
Rs232
9~30V+
9~30V-
485+
485-
Rs485
12
34
5
DB9-Hole
Rs232Connect with PC or Router
ASI-8930 Interface
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
RS485
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
PWD
RxD
TxD
RS
48
5
RS
23
2RS485-RS232Convertor
Co
mp
ute
rIn
terf
ace
T/R+T/R-GND
48
5 2
32
ASI-8930 Interface
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
48
5 2
32
Rj45
ASV-TCP/IPDC9~30V
232
485
Rs232
9~30V+
9~30V-
485+
485-
Rs485
Rs485
RS485\TCP/IP
Connect with PC or Router
ASI-8930 Interface
Product ConnectionProduct Connection
A
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
GN
D1
2V
DA
T0
DA
T1
SW
GN
DM
en
C1
BE
LL
BE
LL
RX
TX
GN
D4
85
+4
85
-2
C2
NO
1N
O1C
1N
C
GN
D
1 2 3
4 5 6
7 8 9
0 #
Function DebuggingFunction Debugging
AS
I-89
30
AS
I-89
30
Invalid Card: If the reader sounds twice after the card is presented to the reading area for one second, the card is invalid.Valid Card: If after the card is presented to the reading area for 0.5 seconds, the reader sounds once, green lights on and delay acts, then the card is valid.
When the buzzer sounds once,Dial “*”, the orange light flashes; Input“000000”, the orange light turns on and device enters program mode. This means the keypad is OK.
1 , 1 1
Adjust the multimeter to , When the power is on, in normal state, 1C- NC is short circuit while C- NO is open circuit. When present the valid card or pressthe exit button, 1C-1NC turns into open circuit, while 1C-1NO is short circuit.
1C1NC
1NO1C
1NC
1NO
Normal State Door-open State
Test Reading Card
Test the Keypad
Test Output
Test Input
If valid default input is normal open, no input available for the device when input signal is open-circuit; while input available when input signal is close-circuit. The status reversed when valid default input is normal close.The user can decide the type of default input setup in the software. 8930 has two input interfaces: SW-GND is button input; MenCi-GND is door magnet input. Both of them can be changed in “channel setup”.
Test Reading Card
ASI-8930 Interface
ASI-8930 Interface
Live Safely and Conveniently
After the exterior device is connected with ASI-8930, please select Tools---Card Register in the software program. Then, select the exterior device and start to read the card. If you can find the card number in the list, it means the exterior device works correctly.
Connect with Exterior Identification Device1. Select the device
2.Start to read card
3. Get the card number
AS
I-89
30
AS
I-89
30
Test the LCD
The LCD will display the Anson and the time, after turn on the power for ASI-8930.
Anson2007-04-16 14:20
1 2 3
4 5 6
7 8 9
0 #
Test the Communication
Rs485
ASI-8930 has two kinds of communication modes: RS232 and RS485. User can chose the communication mode by setting up the jumper. ASI-8930 can connect with PC serial port, and one serial port only connects with one ASI-8930. RS485 signal should be converted to RS232 signal before it can communicate with PC. RS485 can connect with multiple devices. After ASI-8930 is connected with PC, user can detect ASI-8930 address by detecting serial port (please refer to the user manual to setup the address). If “connected” is displayed, the communication is ok. User can get version and model number of ASI-8920 by inputting the address and clicking Auto Detect.
Setup the Jumper
Rs232
Test the time of ASI-8930
Time adjustment is shown in the picture on the left. The time of controller should be in consistent with PC. User can get updated time for controller by press“Refresh”. If controller time is incorrect, card record may get lost, validity of card-read is in doubt, and moreover, valid card may turn into be invalid.
PC time should be in consistent with controller time; otherwise the reader may not work properly.*
Live Safely and Conveniently
Function DebuggingFunction Debugging
Urgent Maintenance:1. When the exterior reader can not read the cards, please
test the voltage of DATA0—GND and DATA1---GND. If the
voltage is less than 3.5V, please weld TVS2, TVS3.2. When door magnet input fails, please test the voltage between Menci and GND. If the voltage is less than 3.5V, please weld TVS5.3. When exit button input fails, please test the voltage between SW and GND. If the voltage is less than 3.5V, please weld TVS4.
PCB
Common Question1. If there is no sound when card is presented to the reading area, the reading function maybe damaged.2. If there is no sound when press the keys, the keypad maybe damaged.3. When add card, if the device exits program mode automatically, the memory maybe damaged.4. If valid card is read and OK light is on, while relay does not act, the lock control may malfunction.5. If relay keeps on in open state, buzzer keeps buzzing, and SW-GND is short or lower than , the keys maybe damaged.6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged.7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can not work properly.8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages.9. The LCD have no information to be displayed, after turn on the power for ASI-8930. The starting program maybe damaged.
The life of products is related to application environment and application method. Please carefully follow the product manual and installation manual.
In case of any problem, please contact with our technical support instead of self- repairment. Please keep the original state of the products when sending back for repairment. Please notify us if you have any special demand, and we will feedback within 48 hours.