Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two –...
Transcript of Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two –...
![Page 1: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/1.jpg)
© 2014 Institute of Nuclear Power Operations
I n s t i t u t e o f N u c l e a r P o w e r O p e r a t i o n s
INPO Perspectives NRC Buried and Underground Piping Meeting June 11, 2014
Joe Sears Manager, Nuclear Asset Protection
![Page 2: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/2.jpg)
© 2014 Institute of Nuclear Power Operations
Key Topics • INPO’s NEI 09-14 role • Industry Performance
–Plant evaluations –Operating experience
• ICES reporting
![Page 3: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/3.jpg)
© 2014 Institute of Nuclear Power Operations
NEI 09-14 INPO’s Role
• Evaluate programs.
• Communicate issues to the industry.
• Compile and report operating experience.
![Page 4: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/4.jpg)
© 2014 Institute of Nuclear Power Operations
Key Topics • INPO’s NEI 09-14 role • Industry Performance
–Plant evaluations –Operating experience
• ICES reporting • Questions
![Page 5: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/5.jpg)
© 2014 Institute of Nuclear Power Operations
Areas for Improvement
5
0
2
4
6
8
10
12
2007 2008 2009 2010 2011 2012 2013 2014
Leaks Program U/G & CP CP TOTAL AFIs
![Page 6: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/6.jpg)
© 2014 Institute of Nuclear Power Operations
2014 Summary • Two AFIs; Four Performance Deficiencies
– Two – underground piping – Four – cathodic protection
• Improvement needed – Degraded coatings and cathodic protection not
properly maintained – Cathodic protection equipment work
prioritization and completion – Cathodic protection site knowledge weaknesses – Leaks occurring and the source is not
determined
![Page 7: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/7.jpg)
© 2014 Institute of Nuclear Power Operations
Good Underground Piping Program Attributes
• ICES reporting quality improvement • Zero leak tolerance – especially in piping
containing radioactive fluids • Cathodic protection installed and maintained • Failure causes identified • Effective station and corporate oversight • Effective use of corrective action program
![Page 8: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/8.jpg)
© 2014 Institute of Nuclear Power Operations
Key Topics • INPO’s NEI 09-14 role • Industry Performance
–Plant evaluations –Operating experience
• ICES reporting
![Page 9: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/9.jpg)
© 2014 Institute of Nuclear Power Operations
May 2014 Number of Reported Events by Year and Failure Mode
80 106 93 106 106
18
8
15 8
5 4
6 12 6 5 5
3
2 4 13 3
4 0
20
40
60
80
100
120
2009 2010 2011 2012 2013 2014
Adverse inspection finding (requires
immediate repair)
Other degradation or maintenance
Significant leak
Leak
Source: ICES
![Page 10: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/10.jpg)
© 2014 Institute of Nuclear Power Operations
Most Commonly Affected Systems
0
50
100
150
200
250
300 Relative to NEI 09-14
![Page 11: Institute of Nuclear Power Operations• Two AFIs; Four Performance Deficiencies – Two – underground piping – Four – cathodic protection • Improvement needed – Degraded](https://reader034.fdocuments.net/reader034/viewer/2022043022/5f3da221055e7a35d72652fb/html5/thumbnails/11.jpg)
© 2014 Institute of Nuclear Power Operations
Contains Licensed Material
5% Safety Related
7%
Contains Environmentally Hazardous Fluid
5%
Other Buried Piping-run to
failure 71%
Other Buried Piping-not run to
failure 12%
Buried Pipe Events Classification