Bits Bag Component Checklist Display Bracket (left) Display Bracket (right) Wall Plate Important Notes TOOLS REQUIRED: Power Drill 12mm ( 1 / 2 ”), 10mm ( 3 / 8 ”) or 7mm ( 1 / 4 ”) Drill Bit Phillips Head Screw Driver Spirit Level 17mm ( 11 / 16 ”) Socket Wrench or Shifter Supports a maximum load of 91kgs (200lbs). Suits displays with mounting hole patterns from 180mm to 810mm wide (7”-31 3 / 4 ”) by 125mm to 500mm high (5”-19 1 / 2 ”). The manufacturer does not accept responsibility for incorrect installation. Security Bracket Mounting Screws M8x15mm / M8x35mm / M8x45mm (x4 each) M6x15mm / M6x35mm / M6x45mm (x4 each) M5x15mm / M5x35mm / M5x45mm (x4 each) M4x15mm / M4x35mm / M4x45mm (x4 each) Cross Recessed Screws Mounting the Wall Plate A Masonry Wall Washer Masonry Wall Plug Wall Plate 12mm ( 1 / 2 ”) Hole Coach Screw Dry Wall Timber Stud Wall TIP: Use a spirit level to ensure the wall plate is horizontal TIP: Use a spirit level to ensure the wall plate is horizontal TIP: Use a spirit level to ensure the wall plate is horizontal Wall Plate Coach Screw Washer Timber Stud 10mm ( 3 / 8 ”) Hole Wall Plate Dry Wall Anchor Dry Wall Anchor Screw Dry Wall Anchor Washer Use a stud finder to precisely locate the timber stud and ensure that the mounting holes are located in the centre of the stud. It is recommended when mounting directly into masonry wall, that the mounting holes are positioned as far apart as possible. 7mm ( 1 / 4 ”) Hole Note: Ensure the Wall Plate is mounted with the folded tabs pointing upwards. Note: Ensure the Wall Plate is mounted with the folded tabs pointing upwards. Note: Ensure the Wall Plate is mounted with the folded tabs pointing upwards. Coach Screw (x4) Masonry Wall Plug (x4) Washer (x4) Multi Washer (x4) Dry Wall Anchor (x6) The dry wall anchors provided in the bit bag have been tested for this wall mount application and will each hold in excess of 30kg per anchor. Before using the expanding anchors, please ensure that you: · Check the plaster board wall (dry wall) is in good condition with no cracks, peeling paper or signs of water damage etc. · Take care installing the anchors, that they are not over tightened or driven into the wall during installation. · Minimum thickness of drywall should be no less than 12mm ( 1 / 2 ”) · Recommend to use all 6 anchors even with light monitor applications. · Only use the anchors supplied in the kit. · Make sure the 10mm ( 3 / 8 ”) pre- drilled hole is as recommended and no smaller or larger. · The anchors during expansion should not interfere with studs or noggins (cross strengtheners). 13mm Spacer Bush (x4) 20mm Spacer Bush (x4) Flat Screen Wall Mount | Tilt TH-3070-UT Installation Instructions

Transcript of Installs TH-3070-UT 19-02-09 (page2) › product... · Installs TH-3070-UT 19-02-09 (page2).ai...

Page 1: Installs TH-3070-UT 19-02-09 (page2) › product... · Installs TH-3070-UT 19-02-09 (page2).ai Author: markn Created Date: 2/19/2009 4:05:09 PM ...

Bits Bag

Component Checklist

Display Bracket (left)

Display Bracket (right)

Wall Plate

Important Notes

TOOLS REQUIRED: Power Drill 12mm (1/2”), 10mm (3/8”) or 7mm (1/4”) Drill Bit Phillips Head Screw Driver Spirit Level 17mm (11/16”) Socket Wrench or Shifter

Supports a maximum load of 91kgs (200lbs).

Suits displays with mounting hole patterns from 180mm to 810mm wide (7”-313/4”) by 125mm to 500mm high (5”-191/2”).

The manufacturer does not accept responsibility for incorrect installation.

Security Bracket

Mounting ScrewsM8x15mm / M8x35mm / M8x45mm (x4 each)

M6x15mm / M6x35mm / M6x45mm (x4 each)

M5x15mm / M5x35mm / M5x45mm (x4 each)

M4x15mm / M4x35mm / M4x45mm (x4 each)Cross Recessed Screws

Mounting the Wall PlateA

Masonry Wall

Washer

MasonryWall Plug

Wall Plate

12mm (1/2”)Hole

Coach Screw

Dry Wall Timber Stud Wall

TIP: Use a spirit level to ensure the wall plate is

horizontal

TIP: Use a spirit level to ensure the wall plate is

horizontal

TIP: Use a spirit level to ensure the wall plate is

horizontal

Wall Plate

Coach ScrewWasher

TimberStud10mm (3/8”)

Hole

Wall Plate

Dry WallAnchor

Dry Wall Anchor Screw

Dry WallAnchor Washer

Use a stud finder to precisely locate the timber stud and ensure that the mounting holes are located in the centre of the stud.

It is recommended when mounting directly into masonry wall, that the mounting holes are positioned as far apart as possible.

7mm (1/4”)Hole

Note: Ensure the Wall Plate is mounted with the folded

tabs pointing upwards.

Note: Ensure the Wall Plate is mounted with the folded

tabs pointing upwards.

Note: Ensure the Wall Plate is mounted with the folded

tabs pointing upwards.

CoachScrew (x4)

Masonry WallPlug (x4)

Washer (x4)MultiWasher (x4)

Dry WallAnchor (x6)

The dry wall anchors provided in the bit bag have been tested for this wall mount application and will each hold in excess of 30kg per anchor.Before using the expanding anchors, please ensure that you:· Check the plaster board wall (dry wall) is in good condition with no cracks, peeling paper or signs of water damage etc.· Take care installing the anchors, that they are not over tightened or driven into the wall during installation.· Minimum thickness of drywall should be no less than 12mm (1/2”)· Recommend to use all 6 anchors even with light monitor applications.· Only use the anchors supplied in the kit.· Make sure the 10mm (3/8”) pre-drilled hole is as recommended and no smaller or larger.· The anchors during expansion should not interfere with studs or noggins (cross strengtheners).

13mm SpacerBush (x4)

20mm Spacer Bush (x4)

Flat Screen Wall Mount | TiltTH-3070-UTInstallation Instructions

maemgarcia
Placed Image
Page 2: Installs TH-3070-UT 19-02-09 (page2) › product... · Installs TH-3070-UT 19-02-09 (page2).ai Author: markn Created Date: 2/19/2009 4:05:09 PM ...

Attaching the display to the wall plate

B

MultiWasher

M6 & M8Screw Hole

M4 & M5 Screw Hole

Mounting screw

C

When attaching the Brackets ensure that both are vertically aligned. Ensure that the tightest fitting hole in the multi washer is used when attaching the mounting screw.

With the brackets attached to the display, lift the display and hook the brackets onto the Wall Plate as shown.

Adjusting TiltD

-5° to 15°tilt adjustment

TIGHTEN

LOOSEN

To adjust the angle of the display, loosen the Tilt Lever located on each bracket then adjust to desired angle. Once in position, tighten each lever firmly.

Tilt Lever

To adjust the Tilt Lever position without tightening or looseningthe lever, pull the lever as shown to dis-engage the ratchetmechanism and rotate the lever into the desired position.

Tilt Lever

PULL

ADJUST

Ensure both Tilt Levers are facing

outwards.

Note: This procedure will require two persons

D.1.

D.2.

Back of display

E

For additional security, it is suggested that a Padlock is attached through the Security Bracket and the Wall Plate on either side as shown. The Padlock (not supplied) should have a shackle diameter no larger than 5mm (3/16”).

No portion of this document or any artwork contained herein should be reproduced in any way without the express written consent of Atdec Pty Ltd. Due to continuing product development, the manufacture reserves the right to alter specifications without notice. Published: 19.02.09©

E.2.E.1.

Recessed Mounting Holes

(not supplied)

Spacer Bush

If the mounting holes are recessedinto the back of the display, usethe appropriate Spacer Bushesprovided to pack the recessed hole.Please note the 13mm SpacerBushes can only be used with M4,M5, and M6 Mounting screws. Ensure the brackets are securelyfixed to the display.