MODEL : WS-608P
Install manualSteam bathroom
No advanced advice will be submit before we change our design and size.
The pictures may be a little different from the real products.
Our company keep the final explanation right.
www.eaglebath.com
01 16
Dear Guest,Thank you very much for purchasing our sanitary ware.
To enable you to use this product safely and effectively,please read this insta llation and operation manual carefullybefore use.
1.Please ensure that the product installed reliable electric leakageprotection device, the power plug contains earth line, and makesure it is reliable earth line. Check the protect system of leakageprotection each time before use.2.Do not turn on water pump, heat pump or air bubble pumpwithout water.3.Before turn on water pump, check if the water level over jets 10to 20 mm or not, make sure regular usage of water pumpotherwise it will be destroy because of water leakage.4.People with Hypertension symptom, after drink or heart diseaseare not allowed to use the bathtub. Children have a bath mustunder adult's guidance.5.During use please noticed that don't blocked the jets andavoiding the air adjustment valve overflowing. Also keep thebathtub clean and don't let it blocked by hair or mess.6.During use, please firstly adjust the water temperature or it willbe burned.7.The bathtub is designed with ergonomic, rise and fall changesare quite big so during usage pay more attention of be slipped.8.Please shut down the system when not to use.
CAUTIONS: Heat pump and air bubble pump is optional purchase.
CAUTIONS
TECHNIQUE PARAMETER
60HZ 0.1~0.2Mpa 2.65KW 1KW 0.2KW1.2HP
Voltage Frequency WaterVolatge
Power ofsteamgenerator
Power ofwater pump
Power ofheat pump
Power ofair pump
Ac ±1 V( 10%)10
Storagecapacity
48gallon
Storagecapacity
0.22m3
WS P-608
Step 1Step 2
Step 3
Self-clean system
Pour into cleaningliquid from here
Step 4
Cleaning method1.C
:lean the steam engine regularly at least once by every 2weeks
or after using 20 times.2.Inject citric acid as main cleaning liquid,add 1.5L eachtime.after 10 minutes, turn on and When the system turns on,press button to start the steam function for about 30secondsand then shut down the system.After vent the stagnantwater,repeat 2 or 3 times.3.CAUTION: The system must be shut down before injecting
“ ”
WS P-608
0215
one tray,one roof, two pieces of up and down bendedaluminum column, two pieces of deluxe shower holdingbar, one set of foot massage, one piece of steam pipe withplastic pad.
three pieces of ABS board, two pieces of sliding glassdoor,two pieces of fixed glass door.
two pieces of “T” shaped pillow,one piece of remotecontrol,two pieces of round shaped handle,one piece ofdrainage cover, four pieces of plastic seal for the post,twose ts of ha nd l e 22 , two se ts of s howe r,M6*25screw(1),M6*35 screw(2),ST4*16 screw(3),ST4*25s c r e w ( 4) , S T 4 * 1 2 s c r e w ( 5 ) , M 5 * 2 5 s c r e w ( 6 ),one instruction.
18pcs
10pcs
M6x25
M6x30
St4x35ST4x25St4x20M4X20
4pcs
48pcs
8pcs
SCREW (1)
SCREW (2)
SCREW (3)SCREW (4)SCREW (5)SCREW (6)
Spare parts list
Packing list
Packing 1
Packing 2
CONSTRUCTION SKETCH
1 body roof23 exhaust fan4 decorated lamp56 cold/hot waterswitch7
、、、、、、
、
movable shower
towel handrail
function switch
8 nozzle、
9、101112
13 control panel14 temperature sensor15 decorated lamp
、、、
、、、
steam room body
top lamptop showermovable shower 16
handrails with glass
12
3
4
5
67
9
8
1012
1415
11
16
1718
20
21
13
19
1617 soap box18 foot massage19 nozzle2021 bottom bathtub
、、、、、、
handrail
Steam outlet box
4pcs
WS P-608WS P-608
1 waterfall2 drainage switch3 water pump swich4 air adjuster5 recycle net6 water jet(6PC)7 drainage
、
、
、
、
、
、
、
INSTALLATION SKETCH
1250(49.2 )″
Cold water pipe
1000(39 )″
The socketof power
Hot water pipe
03 14
ATTENTION1.In order to be tripped and fell down, pay more attention when get into thesteam room. Please don't shut the finger in the door in order to be hurt.2.In order to avoid damaging the surface of products please do not use hardnessand sharpness tool to curve the products.3.In order to course fire, no smoking inside the bathroom.4.the jets of steam and drainage pipe both are high temperature when productsworking, in order to be hurt please be careful.5.In order to be tripped and fell down please keep clear of the bathtub aftertaking shower each time.6.It will be leaking if the glass glue plastic sheet be off then please add somemore for recover.7.If there are marks of water please clear with soft cloth and toothpaste.8.In order to be blocked of drainage device please keep clean of the surface ofbathtub.9.Please do not hang up heavy things on the steam room or the handle of steamroom.10.Please deal with the products according to the local laws when it is nolonger be use.11.Any request please contact with local dealer.
1 check if power and cold/hot water switch be turn on or be turn off each time beforeuse this product.2 check if power of electronic leakage device be get through or not.
3 Turn off the main power of control panel after stop usage. The plug of power shouldbe pull out because only turn off all the functions of control panel that is not stop thepower.4 People with hypertension or drunk are not allowed to have sauna steam bath.5 Children should have sauna steam bath under adult's instruction.6 Please don't shut the finger in the door in order to be hurt when get into the steamroom.7 In order to be tripped and fell down, pay more attention when get into the steamroom.8 keep clean of the tray in order to be tripped and fell down.9 Pay attention to the steam sprayer and water tank drainage, they are in hightemperature while working.
、
、
、
、、、
、
、、
Checking way:Press testing button, light of power be off, press button of restart then light of powerbe on.It is not being what mentioned above after operated step by step,then thatshows the electronic protection device out off control or there is something wrongwith the electronic leakage device,so should ask professional to check and maintainthe product.
ATTENTION FOR USAGE
Size:1600X1600X2250mm63”X63”X88.6”
WS P-608 WS P-608
13
Attention:The machine must be fixed in the circuit which protected
by creepage protectionand should be well-connected with theground. Nontechnical people can not be fixed or removed atrandom.
04
INSTALLATION PROCESS
STEP1
Drain
2 Pls Lock the aluminumcolumns on acrylic panel leftside right side per readyscrew holes by factory
.
&.
1.Assembly of trayIf the ground is not smoothplease adjust the nail under thetray to keep the balance of thetray and ground The steam pipe isin the package box.
,
.
STEP2
ST4X25
Strip C
Strip BStrip A
WS P-608WS P-608
M6X30
12
(1) The electrical pitchPress pitch can open the machine, the temperature
is the room temperature.The time will show 30m. At the sametime, it will open the cei ling lamp.Press again will c lose all thefunctions. (After the closure of the machine, the water case
will drainfor 2 minutes)
(2) The application of the back lampPress ,the sidelight is on. Press again, the ceiling
lamp is out, press a third press, the sidelight is out too.3) The steam function
Press ,startup the steam function, the water casewill pump water automati-cally. After 60minutes or so, itwill generate steam. (When the water case is lack ofwater,the controller will replenish automatically)(4) The air draft function
Under the condition of turnning on, press can startup air draft function, pressagain will colse it.(5) The setting of time or temperature
1. Press pitch can adjust the time from 1-99.2. Press pitch can adjust the temperature from
30-60 .
STEP3ST4X20
3.Pls lock the big bluecoated glass next to thealuminum columns per readyscrews holes by factoryAfter the blue coated glassinstallation pls putdecorated beads oncorresponding place ofaluminum columns
.
。
, .
.
4.Install spare parts onbackside steam room body Theyare movable shower holdertowel handrail glass shelfsoap box This step requirespeople one hold the part infront and another one tightenthe screws at back side Soapbox makes up by one bottom shelf
pcs boxes pls lock thebottom shelf on ready screwholes first and put the boxeson the bottom shelf later
.,
, &. 2
,
.
& 2 , .
,.
STEP4
STEP5
5.Pls carry the backside bodyto the top of bathtub and lockscrews on ready screws holes ontheir contact surface behindthe steam room body In this wayit is fixed
.
. ,.
05 WS P-608 WS P-608
11
Time adjustment pitch-
Time adjustment pitch+ Temperature adjustment pitch-
Temperature adjustment pitch+ Fan Pitch
CeilingLamp/Back Lamp pitch Steam Pitch
Main Cock Pitch
1
23
4
5
6
78
1
234
5
6
78
06
6.Put the blue clearglass with one sidealuminum pole on thebathtub next to theback side blue coatedglass and lock themtogether by lockscrews on thesealuminum polessides blue clearglass with one sidealuminum poleinstallation way isthe same
,
2.2
.
ST4X20
STEP7
ST4X20
7.After the fixed doorinstallation pls lock pcsaluminum poles base on bathtubper ready screw holes Later plsinsert the aluminum poles withhinges into the base At the sametime pls insert sides fixeddoor glass into the groove ofthese aluminum poles first putglass glue into the groove later
, . 2
. , .
., . 2
&.
STEP6
put glass glue here
WS P-608WS P-608
1007
M4x20
STEP8
8.Pls put ceiling on thesteam room body and makesure the ceiling is notover the steam room bodyThen lock the screws as
picture and fix the roombody ceiling Oneperson should hold theceiling inside the room
.
.,
& .
.
Strip C
Strip A
Strip B
9.Install strips magnetic strip onleft right bottom side of pcsmovable glass door Carry the glass doorto the top of bathtub Loose theprotruding hinge part and lock theglass inside the hinge per ready glasshole After the movable doorinstallation pls install door handleon doors
&, & 2
..,
., .
..
STEP9
DRAWING OF ELECTRICITY CONNECTION
steam outlet
water inlet
Controlpanel
Power
Light(AC12V)
Fan(DC12V)
clean system
WS P-608 WS P-608
09
DRAWING OF WATER CONNECTIONAs the from the picture,please make theconnection
“ ”“ ”according to the serial number v1,v2,etc.
Top shower
Movableshower head
Nozzle
Movableshower head
Nozzle Nozzle
Switchvalve
Switchvalve
Cold/hotwater switch
Water fallFootmassage
Cold/hotwater switch
Steam generator
steam outletclean system
08
10.After the steam room installation pls install therest spare parts Such as movable shower foot massage
, .. ,
11.Pls put glass glue on fixed door bottom outsideinside and inside top part
. &.
12.Finish cable water pipe connection pls kindlycheck the attached picture
& . ( .)
WS P-608WS P-608