Installation Temperature Limiting Device installation Temperature Limiting Device 3 1A Position face...

2
Preparation/Assembly • Adjustable wrench • Groove joint plier • Flat screwdriver • Phillips screwdriver • Pipe tape • Hex Wrench • Hacksaw Steps 1-3 Installation Temperature Limiting Device 3 1A Position face of plaster guard flush with face of finish wall. 5 For tub installation only: install nipple for spout. Nipple should extend approximately beyond finished wall. 1. Shut off water supply by turning check valves. Extract right handle (the escutcheon with Hot/Cold mark) and retainer nut. Then, you will see the limiting device on the extension. 2. Adjust limiting device to select opti- mum temperature and to avoid acci- dental scalding. 1 2 3 H125 x W120mm 2 Apply pipe tape onto thread and connect water supply tube to valve assemblies. Make sure that the valves’ hot and cold inlets are on an accurate horizontal plane. Installation Parts diagram 4 6 Install shower arm. 8 Install tub spout. Turn on water and check for leaks. 9 Install shower flange. Installation Steps 7-10 10 Install escutcheon and diverter handle onto valve. 11 Screw in escutcheon and install handle set. Installation Steps 11-14 12-3 Keep the distance (B-1/16”) and cut off the extra cartridge. 13 Adjust the cartridge to be fixed clockwise. Assemble the handle vertically. 14 Install showerhead and tighten with wrench. Turn on water supply. 12-1 Measure the distance between handle and canopy. (distance B) (For fiberglass wall skip step 12) 12-2 Leave 1/16” between canopy & handle head. Apply pipe tape on all pipe threads. Install elbow at one end. Connect other end to shower diverter. Determine whether you’re mounting into a. Drywall or drywall with tile (See figure A & step 1A) b. Fiberglass Wall (See figure B & step 1B) 1B Position plaster guard flush with back of fiberglass wall. Steps 4-6 7 Before installing escutcheon, remove the plastic cap from plaster guard by twisting cap to the clockwise. 1A 1B 2 3 4 5 6 7 8 10 9 11 12-1 12-2 12-3 13 14 a. Remove the two white plastic toothed cams from the valve stem. b. Turn the valve stem so that the round dimple on the stem is at the top. This is the closed position is at the top. (This is the valve closed position with normal plumbing hook-up). "F": DIMPLE up!! I n s t a l l c a m ( A ) o n t o v a l v e s t e m a. Dimple (D) on valve stem and notch (C) on cam A should both point upward. The flat side of cam A should go against the stop (B) b. Rotate valve stem so that cam A is tight to the Stop (B). A BASE CAM B TEMP LIMIT CAM C FIXED STOP D VALVE STEM E ROUND DIMPLE MARK ON STEM F SLOT IN TEMP LIMIT CAM B D G A C CAM A CAM A 4 Trouble-Shooting PROBLEM Leaks underneath handle. CAUSE Retainer nut has come loose or O-ring on cartridge is dirty or twisted. ACTION Tighten the retainer nut. Clean or replace o-ring. PROBLEM Water will not shut off completely. CAUSE Rubber valve seat is dirty or broken. ACTION Remove handle and cartridge to check the rubber valve seat. Clean or replace it. PROBLEM Water temperature can not be adjusted by limiting device, or no hot or cold water. CAUSE Dirty balance spool. ACTION Turn off water supply. Unscrew the balance spool and remove piston and clean with a brush and vinegar water for both parts. Per centage of hot water Recommended Temperatur e limiting device opened at eight notches is recommended high temperature setting Average tempera- ture setting Low temperature setting I n s t a l l t e m p l i m i t c a m ( B ) a. The word "up" should face out b. Install cam onto valve stem so that it fits onto cam A so that there are no tooth gaps between A & B. This allows valve to rotate from closed to full hot position. c. See instructions below to adjust temperature limit stop. CAM B a. With water on to valve, rotate valve stem counter-clock- wise to desired high temperature. Let water run for at least one minute to confirm temperature. b. Set cam "B" so that the flat side is flush with the stop (C). c. Shut off water and re-install handle assembly. Indented mark inbetween "C" and "H" on #04901. Sharp end of #04900.. E F A C B 5 6 7 installation Tools: Safety Tips Things You May Need Important points Maintenance What you need to know Need help? For additional assistance or service call: 1 888 328-2383 USA 1 800 487-8372 CAN 8 a.m. to 8 p.m. EST Monday-Friday 9 a.m. to 5 p.m. EST Saturday & Sunday Your new bathroom faucet is designed for years of trouble-free performance. Keep it looking new by cleaning it periodically with a soft cloth. Avoid abrasive cleaners, steel wool and harsh chemicals as these will dull the finish and void your warranty. Prior to beginning installation, turn off the cold and hot water lines and open the old faucet to release build-up pressure. When installing your new faucet, turn the connector nuts finger- tight, then use one wrench to anchor the fitting and a second wrench to tighten the nut one additional turn. Connections that are too tight will reduce the integrity of the system. Wrap all threaded connections with pipe tape available at your local hardware or plumbing supply store. Always wrap in a clockwise direction. a If soldering during faucet installation, the seats cartridges and washers will have to be removed before using flame. Otherwise, warranty will be void on these parts. Protect your eyes with safety glasses when cutting or soldering water supply line. Cover your drain to avoid loosing parts. All installations can vary depending on how your previous faucet was installed. Not all supplies for faucet installation are included; however they are available wherever plumbing supplies are sold. When choosing your installation supplies, make sure they are IAPMO and/or CSA approved products. For models: 459849,459885 1/16" For tub installation only: repeat step 2 for tub spout. CAUTION: In order to assure proper function, piping from the bottom port of valve to tub spout outlet MUST be either 1/2” nominal copper pipe or 1/2” iron pipe. CAUTION: In order to assure proper function, piping from the bottom port of valve to tub spout outlet MUST be either 1/2” nominal copper pipe or 1/2” iron pipe. F1325700YP F1228100YP_HDK5 10. 9. 7. 8. 6. 5. 4. 19. 20. 11. 12. 13. 14. 15. 16. 17. 18. 21. 1. 2. 3. 1 Shower Head S11B0204 2 Shower Arm A020002 3 Shower Arm Flange A019298 4 Handle Cap A66D803 5 Metal Handle Assembly A66E591H 6 Screw Set(3/16" -24 * 2-15/16" L) A668209 7 Screw Set(3/16" -24 * 1-5/8" L) A608232 8 Plaster Guard A127006 9 Base Nut A009281 10 Retainer Nut A103034 11 Sleeve A217031 12 Temperature Limiting Device A603570 13 Cartridge Assembly A603567 14 Seat & Spring Set A603177 15 Check Valve A603120 16 Pressure Balance Spool A507041 17 Diverter Assembly A607223 18 Escutcheon Assembly A66F114 19 Spout Escutcheon A303071 20 Spout A523265 21 Hex Wrench (H3.18 *20 mm L * 90 mm L) A031017NI

Transcript of Installation Temperature Limiting Device installation Temperature Limiting Device 3 1A Position face...

Page 1: Installation Temperature Limiting Device installation Temperature Limiting Device 3 1A Position face of plaster guard flush with face of finish wall. 5 For tub installation only: install

Preparation/Assembly• Adjustable wrench

• Groove joint plier

• Flat screwdriver

• Phillips screwdriver

• Pipe tape

• Hex Wrench

• Hacksaw

Steps 1-3

Installation Temperature Limiting Device

3

1A Position face of plaster guard flush with face of finishwall.

5 For tub installation only: install nipple for spout. Nippleshould extend approximately beyond finished wall.

1. Shut off water supply by turningcheck valves. Extract right handle(the escutcheon with Hot/Coldmark) and retainer nut. Then, youwill see the limiting device on theextension.

2. Adjust limiting device to select opti-mum temperature and to avoid acci-dental scalding.

1 2

3

H125 x W120mm

2 Apply pipe tape onto thread and connect water supplytube to valve assemblies. Make sure that the valves’ hotand cold inlets are on an accurate horizontal plane.

Installation

Parts diagram

4

6 Install shower arm.

8 Install tub spout. Turn on water and check for leaks.

9 Install shower flange.

Installation

Steps 7-10

10 Install escutcheon and diverter handle onto valve.

11 Screw in escutcheon and install handle set.

Installation

Steps 11-14

12-3 Keep the distance (B-1/16”) and cut off the extra cartridge.

13 Adjust the cartridge to be fixed clockwise. Assemble thehandle vertically.

14 Install showerhead and tighten with wrench. Turn onwater supply.

12-1 Measure the distance between handle and canopy. (distance B) (For fiberglass wall skip step 12)

12-2 Leave 1/16” between canopy & handle head.

Apply pipe tape on all pipe threads. Install elbow at oneend. Connect other end to shower diverter.

Determine whether you’re mounting intoa. Drywall or drywall with tile (See figure A & step 1A)b. Fiberglass Wall (See figure B & step 1B)

1B Position plaster guard flush with back of fiberglass wall.

Steps 4-6

7 Before installing escutcheon, remove the plastic capfrom plaster guard by twisting cap to the clockwise.

1A

1B

2

3

4

5

6

7

8

10

9

11

12-1

12-2

12-3

13

14

a. Remove the two white plastic toothed cams from thevalve stem.b. Turn the valve stem so that the round dimple on thestem is at the top. This is the closed position is at the top.(This is the valve closed position with normal plumbinghook-up).

"F": DIMPLEup!!

Install cam (A) onto valve stema. Dimple (D) on valve stem and notch (C) on cam A shouldboth point upward. The flat side of cam A should goagainst the stop (B)b. Rotate valve stem so that cam A is tight to the Stop (B).

A BASE CAMB TEMP LIMIT CAMC FIXED STOPD VALVE STEME ROUND DIMPLE MARK ON STEMF SLOT IN TEMP LIMIT CAM B

DG

AC

CAM A

CAM A

4

Trouble-ShootingPROBLEMLeaks underneath handle.CAUSERetainer nut has come loose or O-ring on cartridge is dirty ortwisted.ACTIONTighten the retainer nut. Clean or replace o-ring.

PROBLEMWater will not shut off completely.CAUSERubber valve seat is dirty or broken.ACTIONRemove handle and cartridge to check the rubber valve seat.Clean or replace it.

PROBLEMWater temperature can not be adjusted by limiting device, or no hot or cold water.CAUSEDirty balance spool.ACTIONTurn off water supply. Unscrew the balance spool and removepiston and clean with a brush and vinegar water for bothparts.

Per centage of hot water RecommendedTemperatur e limiting device opened at eight notches is recommended

high temperaturesetting

Average tempera-ture setting Low temperature

setting

Install temp limit cam (B)a. The word "up" should face outb. Install cam onto valve stem so that it fits onto cam A sothat there are no tooth gaps between A & B. This allowsvalve to rotate from closed to full hot position.c. See instructions below to adjust temperature limit stop.

CAM B

a. With water on to valve, rotate valve stem counter-clock-wise to desired high temperature. Let water run for at leastone minute to confirm temperature. b. Set cam "B" so that the flat side is flush with the stop (C). c. Shut off water and re-install handle assembly.

Indented markinbetween "C"and "H" on#04901.

Sharp end of#04900..

E

F

A

C B

5

6

7

ins

tall

ati

on Tools:

Safety Tips

Things You May Need

Important points

Maintenance

What you need to know

Need help?For additional assistance or service call:1 888 328-2383 USA 1 800 487-8372 CAN 8 a.m. to 8 p.m. EST Monday-Friday9 a.m. to 5 p.m. EST Saturday & Sunday

Your new bathroom faucet is designed foryears of trouble-free performance.

Keep it looking new by cleaning it periodically with a softcloth. Avoid abrasive cleaners, steel wool and harsh chemicalsas these will dull the finish and void your warranty.

Prior to beginning installation, turn off the cold and hot waterlines and open the old faucet to release build-up pressure.When installing your new faucet, turn the connector nuts finger-tight, then use one wrench to anchor the fitting and a secondwrench to tighten the nut one additional turn. Connections thatare too tight will reduce the integrity of the system.Wrap all threaded connections with pipe tape available atyour local hardware or plumbing supply store. Always wrap ina clockwise direction. a

• If soldering during faucet installation, the seats cartridges and washers will have to be removed before using flame. Otherwise, warranty will be void on these parts.• Protect your eyes with safety glasses when cutting or

soldering water supply line. • Cover your drain to avoid loosing parts.

All installations can vary depending on how your previous faucet was installed. Not all supplies for faucetinstallation are included; however they are available wherever plumbing supplies are sold. Whenchoosing your installation supplies, make sure they are IAPMO and/or CSA approved products.

For models: 459849,459885

1/16"

For tub installation only: repeat step 2 for tub spout.CAUTION: In order to assure proper function, piping from the bottom port of valve to tub spout outlet MUST be either 1/2” nominal copper pipe or 1/2” iron pipe.

CAUTION: In order to assure proper function, piping from the bottom port of valve to tub spout outlet MUST be either 1/2” nominal copper pipe or 1/2” iron pipe.

F1325700YP F1228100YP_HDK5

10.9.7.

8.

6.

5.

4.

19.

20.

11.12.

13. 14.

15.

16.

17.

18.21.

1.

2.

3.

1 Shower Head S11B02042 Shower Arm A0200023 Shower Arm Flange A0192984 Handle Cap A66D8035 Metal Handle Assembly A66E591H6 Screw Set(3/16" -24 * 2-15/16" L) A6682097 Screw Set(3/16" -24 * 1-5/8" L) A6082328 Plaster Guard A1270069 Base Nut A00928110 Retainer Nut A10303411 Sleeve A21703112 Temperature Limiting Device A60357013 Cartridge Assembly A60356714 Seat & Spring Set A60317715 Check Valve A60312016 Pressure Balance Spool A50704117 Diverter Assembly A60722318 Escutcheon Assembly A66F11419 Spout Escutcheon A30307120 Spout A52326521 Hex Wrench (H3.18 *20 mm L * 90 mm L) A031017NI

Page 2: Installation Temperature Limiting Device installation Temperature Limiting Device 3 1A Position face of plaster guard flush with face of finish wall. 5 For tub installation only: install

Instalación del grifo

Pasos 1-3

Instalación

Pasos 4-6

3

5 Solamente para la instalaciòn de bañera: instale laboquilla para el pico. La boquilla debe de extender aprox-imadamente màs alla de la pared terminada.

H125 x W120mm

2 Aplique cinta de teflòn a la rosca y conecte el tubo delsuministro del agua a los ensamblajes de la vàlvula.Asegurese que las vàlvulas de las entradas de caliente yfrìa esten en un plano horizontal exacto.

Determine el tipo de pared:a. yeso y azulejo (Fig. A)b. Armazón de fibra de vidrio (Fig. B)

Instalación

Repuestos

4

6 Instale el brazo de la ducha.

8 Instale el pico de la bañera. Abra el suministro del aguay revise que no gotee.

7 Antes de instalar la placa, remueva la tapa plástica delbase para pared, girando la tapa en el sentido de lasagujas del reloj.

9 Instale la brida de la ducha.

Instalación

Pasos 7-10

10 Instale el escudo y la manija del desviador a la vàlvula.

11 Atornille el escudo e instale el juego de manija.

Instalación

Pasos 11-14

12-3 Mantenga la distancia (B – 1/16”) y corte el cartuchorestante.

13 Ajuste el cartucho para arreglarse en direcciòn de lasmanecillas del reloj. Ensamble las manijas verticalmente.

14 Instale la cabeza de la ducha y apriete con una llave.Abra el suministro del agua.

Mida la distancia entre la manija y la cubierta. (distanciaB) (Para armazón de fibra de vidrio saltese lo paso 12)

12-2

12-1

Deje 1/16” entre la cubierta y la cabeza de la manija.

Aplique cinta de teflòn a todas las roscas. Instale el codoen un extremo. Conecte el otro extremo al desviador dela ducha.

• Llave ajustable• Pinzas ajustables• Destornillador Llano• Destornillador cruciforme• Cinta selladora para rosca• Llave hexngonal• Sierra para metales

2

3

1A Coloque el frente del protector de pared contra la pared.

1B Coloque el protector de pared contra la parte de atrás dela pared de fibra de vidrio. 4

5

6

7

8

10

9

11

12-1

12-2

12-3

13

14

1BLa pared de fibra de vidrio

Protector de pared

1AYeso

La pared

Protector de paredin

sta

lac

ión Dispositivo de Limitación de Temperatura

1. Cierre el suministro del agua girandolas válvulas de retención. Extraiga lamanija derecha (el escudo marcadocon Caliente/Frío) y tuerca de reten-ción. Entonces podra ver el dispositi-vo de limitación en la extensión.

2. Ajuste el dispositivo de limitaciónpara seleccionar la temperatura opti-ma y evitar quemaduras acciden-tales.

1 2

3 a. Saque las dos levas de plástico serradas delvástago de la válvula.b. Gire el vástago de la válvula hasta que la cavi-dad circular quede hacia arriba. (Esta es la posi-ción de cerrado en una instalación normal.)

4 Instalación de la leva (A) en el vástago de la válvulaa. Tanto la cavidad (D) en el vástago de la válvulacomo la ranura (c) en la leva A deben estar haciaarriba.El lado chato de la leva A debe estar contrael tope (B).b. Gire el vástago de la válvula para que la leva Aquede ajustada contra el tope (B).A LEVA BASEB LEVA DE LÍMITE DE TEMPERATURAC TOPE FIJOD VÁSTAGO DE VÁLVULAF CAVIDAD CIRCULAR EN EL VÁSTAGOG RANURA EN LA LEVA

“F”: CAVIDADCIRCULARhacia arriba

ARRIBA

ARRIBAD

G

AC

Leva (A)Cerrado

Leva (A)

ARRIBA

Solución de ProblemasPROBLEMAGoteo debajo de la manija.CAUSALa manga se ha aflojado. La arandela circular está sucia odañada.SOLUCIONApriete la tuerca de ajuste. Limpie o reemplace la arandela cir-cular.

PROBLEMAEl agua no se cierra completamente.CAUSAEl asiento de caucho está sucio o roto.

SOLUCIONRemueva la manija y el cartucho para chequear el asiento decaucho.

PROBLEMALa temperatura del agua no se ajusta con el dispositivo delimitación, o no hay agua caliente o fría. CAUSABobina de balance está suciaSOLUCIONCierre el suministro del agua. Desatornille la bobina de bal-ance y quite el pistón. Limpie ambas partes con un cepillo yagua de vinagre.

Para temperaturaalta

Dientes: 0

Para temperaturamedia Para temperatura

baja

Por centage de agua caliente R ecomendaciónSe recomienda no más de acho

Dientes

: 8

Dien

tes:

12

5 Instalación de la leva de límite de temperatura (B)a. La palabra “up” debe estar hacia fuerab. Instale la leva en el vástago de la válvula paraque calce en la leva A y no quede separación entrelos dientes A y B. Esto permite que la válvula gire dela posición cerrada a la de agua completamentecaliente.c. En las instrucciones que siguen verá cómo ajustarel tope de la temperatura.(INSTALACIÓN Y AJUSTE DE LA TEMPERATURA)

LEVA B

6 a. Con el agua conectada a la válvula, gire el vástagode la válvula en sentido contrario a las agujas del relojhasta la temperatura deseada. Deje correr el agua unminuto, por lo menos, para comprobar que la temper-atura esté bien.b. Coloque la leva “B” para que la parte chata quedecontra el tope (C).c. Cierre el agua e instale la manivela.

Muesca entre“C” y “H” en elNro. 04901

Extremo agudoen el Nro.04900

E

F

8 dien

tes

A

C B

Para modelos: 459849,459885

Herramientas: Mantenimiento

Consejos de seguridad

Cosas que puede necesitar

Información importante

Su grifo nuevo para baño está diseñado para brindar años derendimiento sin problemas.Mantenga el grifo como nuevo limpiándolo periódicamente conun paño suave. No utilice limpiadores abrasivos, virutas deacero ni substancias químicas fuertes ya que opacarán elacabado y la garantía se anulará.

Lo que necesita saber

Requiere asistencia?Para obtener mayor información o servicio,llame al:

1 888 328-2383 USA 1 800 487-8372 CAN8 a.m. a 8 p.m. EST lunes a viernes9 a.m. a 5 p.m. EST sábado y domingo

• En el caso de utilizar soldadura para instalar el grifo,remueva los asientos, cartuchos y arandelas antes de

• Protéjase los ojos con gafas de seguridad cuandocorte o suelde las tuberías de agua

• Tape la boca del desagüe para prevenir la pérdida depiezas pequeñas

usar la llama.De lo contrario, la garantía sobre estos componentes quedará anulada.

?

Todas las instalaciones pueden variar dependiendo de cómo instaló su grifo anterior. No todas las herramientas necesarias para la instalación del grifo están incluidas. No obstante, puede obtenerlas en cualquier establecimiento donde vendan artículos de plomería. Al seleccionar sus herramientas para la instalación, asegúrese de que sean productos aprobados por IAPMO y/o CSA.

Antes de comenzar la instalación, cerciórese de cerrar todas las conexiones y cañerías de agua fría y caliente, y de abrir el grifo antiguo para liberar la presión acumulada. Al instalar el nuevo grifo, apriete a mano las tuercas de conexión, luego utilice dos llaves; una para anclar la conexión y la otra para apretar la tuerca con un giro adicional. Las conexiones demasiado apretadas menoscaban la integridad del sistema.Envuelva con cinta de Teflón (disponible en cualquier ferretería o tienda de plomería de su localidad) todas las conexiones roscadas. Siempre envuelva en sentido de las agujas del reloj. Los componentes deben ser instalados por un plomero con licencia estatal

1/16"

Solamente para la instalación de bañera: repita el paso 2 para el vertedor de la bañera.ADVERTNCIA: Para asegurar el buen funcionamiento, la tubería de la boca inferior de la válvula al grifo de la bañera DEBE SER de cobre de 1/2” o de hierro de 1/2”.

ADVERTNCIA: Para asegurar el buen funcionamiento, la tubería de la boca inferior de la válvula al grifo de la bañera DEBE SER de cobre de 1/2” o de hierro de 1/2”.

10.9.7.

8.

6.

5.

4.

19.

20.

11.12.

13. 14.

15.

16.

17.

18.21.

1.

2.

3.

1 Cabeza de ducha S11B02042 Brazo de ducha A0200023 Brida del brazo de la ducha A0192984 Tapón A66D8035 Ensamblaje de manija metálicas A66E591H6 Juego de tornillo A6682097 Juego de tornillo A6082328 Placa para pared A1270069 Tuerca de la base A00928110 Tuerca de retención A10303411 Manga A21703112 Dispositivo para limitar la temperatura A60357013 Ensamblaje de cartucho A60356714 Asiento y tuerca de resorte A60317715 Válvula de control A60312016 Juego de bobina de presiòn balanceada A50704117 Ensamblaje de transferencia A60722318 Ensamblaje del Escudo A66F11419 Escudo del vertedor A30307120 Vertedor A52326521 Llave hexagonal A031017NI

F1325700YP F1228100YP_HDK5 INS_S