INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers...

24
High Capacity Architectural Linear Diffuser Custom Flow Series v100 Issue Date: 01/22/18 © 2018 Price Industries Limited. All rights reserved. MANUAL – INSTALLATION + SERVICE

Transcript of INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers...

Page 1: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

High Capacity Architectural Linear Diffuser Custom Flow Series

v100 – Issue Date: 01/22/18© 2018 Price Industries Limited. All rights reserved.

MANUAL – INSTALLATION + SERVICE

Page 2: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

CUSTOM FLOWTABLE OF CONTENTS

Product Overview

Overview .......................................................................1

Before You Start ............................................................1

Getting Started ..............................................................1

Installation & Mounting Instructions

(Surface Mount Drywall Applications)

Type C Mounting

(Concealed Mounting Bracket) ......................................2

Type MP-DR Mounting

(Reversible Drywall Mounting Clip) .................................5

Type A Mounting (Countersunk Holes) ...........................7

Drywall Finishing for CMF Frame ...................................9

Installation & Mounting Instructions

(Tee Bar Lay-In Applications)

General Installation ......................................................10

Field Trimming ..............................................................12

Pattern Controller Adjustment ....................................14

Parts List .......................................................................16

Page 3: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

1priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWPRODUCT OVERVIEW

Product OverviewCF: High capacity architectural linear slot air diffuser. Recommended for use in ceiling applications. Also available to be used in sidewall applications.

CFP: Corresponding engineered plenum for CF diffuser.

UP/UPL: Universal plenum available for CF diffusers (low profile option available)

The diffuser/plenum will have one sticker located on the outside of the frame. For ease of troubleshooting assistance, replacement parts, and general factory assistance, it is recommended that the order number and model line string be available for reference. This information can be found on the Factory Label.

Before You StartInspect all cartons and boxes for flaws and shipping damage. If anything is discovered to be damaged, contact the shipping company and file a freight claim.

Getting StartedSTEP 1: Remove CF linear diffuser from shipping carton and inspect for any damage.

STEP 2: Refer to Factory Label to determine the application of the diffuser. For surface mount applications (SM), proceed to STEP 3. For tee bar lay-in applications (LI), proceed to page 10.

Sample line string: CF//I/IN//AS/1/48.000/1/SS//SM///CMF/XX///C///DPC///BFR//////B12

STEP 3: Refer to Factory Label to determine the diffuser’s mounting option. Use the following table for appropriate reference page for the particular mounting option.

Sample line string: CF//I/IN//AS/1/48.000/1/SS//SM///CMF/XX///C///DPC///BFR//////B12

Mounting Type Line String Sample Page Number

Concealed Mounting Bracket C 2

Reversible Drywall Mounting Clip MP-DR 5

Countersunk Holes A 7

ORDER NUMBER

LINE STRING

Page 4: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

2 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (SURFACE MOUNT DRYWALL APPLICATIONS)

This section applies to Custom Flow linear diffusers (model CF) for installation in surface mount drywall applications (SM application) in both ceilings and sidewalls.

Sample line string: CF//I/IN//AS/1/48.000/1/SS//SM///CMF/XX///C///DPC///BFR//////B12

Type C Mounting (Concealed Mounting Bracket)Available frame styles: EF, CMF

Sample line string: CF//I/IN//AS/1/48.000/1/SS//SM///CMF/XX///C///DPC///BFR//////B12

STEP 1: Ensure that the correct number of concealed mounting bracket kits has been shipped using the following table as reference.

STEP 2: Frame opening. Refer to chart for recommended opening width dimension. If no plenum is used, opening width may be additionally reduced by up to 1/4” (6 mm).

STEP 3: Install plenum (if required). Use price model CFP, UP, UPL, or field built plenum with hemmed edges. Secure plenum to framing or hang from structure as required by local building code. Plenum may be installed flush to framing, or located to be flush with finished drywall.

Diffuser Section Length Kit QTY.

Nom. Length ≤ 24” 2

24” < Nom. Length ≤ 48” 2

48" < Nom. Length ≤ 72" 3

72" < Nom. Length ≤ 96" 3

96” < Nom. Length ≤ 120” 4

Slot Size Slot QTY. Opening Width

1” (25 mm)1 3 3/8” (86 mm)

2 5 11/16” (144 mm)

1 1⁄2” (38 mm)1 4 3/8” (111 mm)

2 7 11/16” (195 mm)

2” (51 mm)1 5 3/8” (137 mm)

2 9 11/16” (246 mm)

2 1⁄2” (64 mm)1 6 3/8" (162 mm)

2 11 11/16” (297 mm)

3” (76 mm)1 7 3/8” (187 mm)

2 13 11/16” (348 mm)

OF REV.SHEET 1 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'C' MOUNTING (CONCEALED MOUNTING BRACKETS).

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP, UP, UPL, OR FIELD BUILD PLENUM WITH HEMMED EDGES. SECURE PLENUM TO FRAMING ORHANG FROM STRUCTURE AS REQUIRED BY LOCAL BUILDING CODE. PLENUM MAY BE INSTALLED FLUSH TO FRAMING, OR LOCATED TO BE FLUSH WITHFINISHED DRYWALL.

STEP 3:INSTALL DRYWALL. IF USING FRAME STYLE EF, FINISH DRYWALL AND PAINT. IF USING FRAME STYLE CMF, DO NOT FINISH DRYWALL UNTIL AFTERINSTALLING DIFFUSER.

IF NO PLENUM IS BEING USED, A LEDGE MAY BE ADDED FOR INSTALLING BRACKET. THIS MAY BE FORMED BY THE DRYWALL, A SHEET METAL HEM ORANGLE, OR METAL STUD FRAMING. IF NO LEDGE IS INSTALLED, BRACKET MAY ALSO BE SCREWED IN PLACE.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSHTO DRYWALL SURFACE

PLENUM EDGE FLUSHTO FRAMING

OF REV.SHEET 1 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'C' MOUNTING (CONCEALED MOUNTING BRACKETS).

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP, UP, UPL, OR FIELD BUILD PLENUM WITH HEMMED EDGES. SECURE PLENUM TO FRAMING ORHANG FROM STRUCTURE AS REQUIRED BY LOCAL BUILDING CODE. PLENUM MAY BE INSTALLED FLUSH TO FRAMING, OR LOCATED TO BE FLUSH WITHFINISHED DRYWALL.

STEP 3:INSTALL DRYWALL. IF USING FRAME STYLE EF, FINISH DRYWALL AND PAINT. IF USING FRAME STYLE CMF, DO NOT FINISH DRYWALL UNTIL AFTERINSTALLING DIFFUSER.

IF NO PLENUM IS BEING USED, A LEDGE MAY BE ADDED FOR INSTALLING BRACKET. THIS MAY BE FORMED BY THE DRYWALL, A SHEET METAL HEM ORANGLE, OR METAL STUD FRAMING. IF NO LEDGE IS INSTALLED, BRACKET MAY ALSO BE SCREWED IN PLACE.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSHTO DRYWALL SURFACE

PLENUM EDGE FLUSHTO FRAMING

OF REV.SHEET 1 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'C' MOUNTING (CONCEALED MOUNTING BRACKETS).

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP, UP, UPL, OR FIELD BUILD PLENUM WITH HEMMED EDGES. SECURE PLENUM TO FRAMING ORHANG FROM STRUCTURE AS REQUIRED BY LOCAL BUILDING CODE. PLENUM MAY BE INSTALLED FLUSH TO FRAMING, OR LOCATED TO BE FLUSH WITHFINISHED DRYWALL.

STEP 3:INSTALL DRYWALL. IF USING FRAME STYLE EF, FINISH DRYWALL AND PAINT. IF USING FRAME STYLE CMF, DO NOT FINISH DRYWALL UNTIL AFTERINSTALLING DIFFUSER.

IF NO PLENUM IS BEING USED, A LEDGE MAY BE ADDED FOR INSTALLING BRACKET. THIS MAY BE FORMED BY THE DRYWALL, A SHEET METAL HEM ORANGLE, OR METAL STUD FRAMING. IF NO LEDGE IS INSTALLED, BRACKET MAY ALSO BE SCREWED IN PLACE.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSHTO DRYWALL SURFACE

PLENUM EDGE FLUSHTO FRAMING

Page 5: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

3priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (SURFACE MOUNT DRYWALL APPLICATIONS)

STEP 4: Install drywall. If using frame style EF, finish drywall and paint. If using frame style CMF, do not finish drywall until after installing diffuser.

If no plenum is being used, a ledge may be added for installing bracket. This may be formed by the drywall (A), a sheet metal hem (B) or angle (C), or metal stud framing (D). If no ledge is installed, bracket may also be screwed in place.

STEP 5: Prepare brackets by inserting one screw through each inner bracket, and pushing rubber grommet down shaft of screw.

STEP 6: Thread outer brackets about 1/4” (6 mm) onto screws.

STEP 7: Install brackets onto diffuser. Deflect side frames and snap brackets under diffuser frame. Brackets are required approximately every 36” (914 mm) to 48” (1219 mm), with one on each end. Ensure that pattern controllers are positioned to the side so that screw may be accessed through diffuser slot.

OF REV.SHEET 1 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'C' MOUNTING (CONCEALED MOUNTING BRACKETS).

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP, UP, UPL, OR FIELD BUILD PLENUM WITH HEMMED EDGES. SECURE PLENUM TO FRAMING ORHANG FROM STRUCTURE AS REQUIRED BY LOCAL BUILDING CODE. PLENUM MAY BE INSTALLED FLUSH TO FRAMING, OR LOCATED TO BE FLUSH WITHFINISHED DRYWALL.

STEP 3:INSTALL DRYWALL. IF USING FRAME STYLE EF, FINISH DRYWALL AND PAINT. IF USING FRAME STYLE CMF, DO NOT FINISH DRYWALL UNTIL AFTERINSTALLING DIFFUSER.

IF NO PLENUM IS BEING USED, A LEDGE MAY BE ADDED FOR INSTALLING BRACKET. THIS MAY BE FORMED BY THE DRYWALL, A SHEET METAL HEM ORANGLE, OR METAL STUD FRAMING. IF NO LEDGE IS INSTALLED, BRACKET MAY ALSO BE SCREWED IN PLACE.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSHTO DRYWALL SURFACE

PLENUM EDGE FLUSHTO FRAMING

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

(A) (B) (C) (D)

1 SLOT 2 SLOT

Page 6: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

4 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (SURFACE MOUNT DRYWALL APPLICATIONS)

STEP 8: Position diffuser in opening. Using a screwdriver, push upward on screw until bracket snaps into place. If diffuser is multiple sections in length, align sections using Y-end splice plates. Tighten screws until frame is flush with drywall.

STEP 9: If using frame style CMF, finish drywall as per page 9.

STEP 10: Adjust pattern controllers for desired air pattern as per page 14 & 15.

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

ALIGN DIFFUSER WITH OPENING PUSH UPWARD UNTIL BRACKET SNAPS INTO PLACE

TIGHTEN UNTIL FRAME IS FLUSH WITH DRYWALL

Page 7: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

5priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (SURFACE MOUNT DRYWALL APPLICATIONS)

Type MP-DR Mounting (Reversible Drywall Mounting Clip)Available frame styles: EF, CMF

Sample line string: CF//I/IN//AS/1/48.000/1/SS//SM///CMF/XX///MP-DR///DPC///BFR//////B12

STEP 1: Ensure that the correct number of reversible drywall mounting clips has been shipped using the following table as reference.

STEP 2: Frame opening. Refer to chart for recommended opening width dimension. If no plenum is used, opening width may be additionally reduced by up to 1/4” (6 mm).

STEP 3: Install plenum (if required). Use Price model CFP, UP, UPL, or field built plenum. Secure plenum to framing or hang from structure as required by local building code. Plenum must be installed flush to framing.

Diffuser Section Length Clip QTY.

Nom. Length ≤ 24” 4

24” < Nom. Length ≤ 48” 6

48" < Nom. Length ≤ 72" 8

72" < Nom. Length ≤ 96" 10

96” < Nom. Length ≤ 120” 12

Slot Size Slot QTY. Opening Width

1” (25 mm)1 3 3/8” (86 mm)

2 5 11/16” (144 mm)

1 1⁄2” (38 mm)1 4 3/8” (111 mm)

2 7 11/16” (195 mm)

2” (51 mm)1 5 3/8” (137 mm)

2 9 11/16” (246 mm)

2 1⁄2” (64 mm)1 6 3/8" (162 mm)

2 11 11/16” (297 mm)

3” (76 mm)1 7 3/8” (187 mm)

2 13 11/16” (348 mm)

OF REV.SHEET 1 2 0

CFINSTALLATION

INSTRUCTIONS

TYPE MP-DR MOUNTING

II00061

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOWTYPE MP-DR MOUNTING

2018/01/03

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP,UP, UPL, OR FIELD BUILD PLENUM. SECURE PLENUM TOFRAMING OR HANG FROM STRUCTURE AS REQUIRED BYLOCAL BUILDING CODE. PLENUM MUST BE INSTALLEDFLUSH TO FRAMING.

STEP 4:IF DIFFUSER IS MULTIPLE SECTIONS IN LENGTH, CONTINUE INSTALLING SECTIONS WHILE ALIGNING SECTIONS USING Y-END SPLICE PLATES.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSH TO FRAMING(PLENUM EDGE MAY BE HEMMED OR FLAT)

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'MP-DR' MOUNTING (REVERSIBLE DRYWALL MOUNTING CLIP). DIFFUSER INSTALLATION IS TO BE DONE PRIOR TO DRYWALLINSTALLATION.

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

STEP 3:SCREW DRYWALL MOUNTING CLIPS TO FRAMING. MOUNTING CLIPS SHOULD BELOCATED AT LEAST EVERY 24" (610). CLIPS MAY BE REVERSED TO ALLOW FOREITHER 5/8" (16) OR 1/2" (13) DRYWALL.

2X Y-ENDSPLICE PLATE

USE THIS ORIENTATIONFOR 5/8" DRYWALL

USE THIS ORIENTATIONFOR 1/2" DRYWALL

OF REV.SHEET 1 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'C' MOUNTING (CONCEALED MOUNTING BRACKETS).

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP, UP, UPL, OR FIELD BUILD PLENUM WITH HEMMED EDGES. SECURE PLENUM TO FRAMING ORHANG FROM STRUCTURE AS REQUIRED BY LOCAL BUILDING CODE. PLENUM MAY BE INSTALLED FLUSH TO FRAMING, OR LOCATED TO BE FLUSH WITHFINISHED DRYWALL.

STEP 3:INSTALL DRYWALL. IF USING FRAME STYLE EF, FINISH DRYWALL AND PAINT. IF USING FRAME STYLE CMF, DO NOT FINISH DRYWALL UNTIL AFTERINSTALLING DIFFUSER.

IF NO PLENUM IS BEING USED, A LEDGE MAY BE ADDED FOR INSTALLING BRACKET. THIS MAY BE FORMED BY THE DRYWALL, A SHEET METAL HEM ORANGLE, OR METAL STUD FRAMING. IF NO LEDGE IS INSTALLED, BRACKET MAY ALSO BE SCREWED IN PLACE.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSHTO DRYWALL SURFACE

PLENUM EDGE FLUSHTO FRAMING

Page 8: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

6 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (SURFACE MOUNT DRYWALL APPLICATIONS)

STEP 4: Screw drywall mounting clips to framing. Mounting clips should be located at least every 24” (610 mm). Clips may be reversed to allow for either 5/8” (16 mm) or 1/2” (13 mm) drywall.

STEP 5: If diffuser is multiple sections in length, continue installing sections while aligning sections using Y-end splice plates.

STEP 6: Install drywall by sliding behind diffuser face and fastening to framing. For easiest installation, slide tapered edge of sheet behind diffuser face.

STEP 7: Finish and paint drywall. If using frame style CMF, finish drywall as per page 9.

STEP 8: Adjust pattern controllers for desired air pattern as per page 14 & 15.

OF REV.SHEET 2 2 0

CFINSTALLATION

INSTRUCTIONS

TYPE MP-DR MOUNTING

II00061

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOWTYPE MP-DR MOUNTING

2018/01/03

STEP 5:INSTALL DRYWALL BY SLIDING BEHIND DIFFUSER FACE AND FASTENING TO CEILING FRAMING. FOR EASIEST INSTALLATION, SLIDE TAPERED EDGE OFSHEET BEHIND DIFFUSER FACE.

PARTS LIST:

DESCRIPTION PART NUMBER

Y-END SPLICE PLATE 255152-001

REVERSIBLE DRYWALL MOUNTING CLIP

255149-001

STEP 6:FINISH AND PAINT DRYWALL. IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTION II00030.

STEP 7:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATION INSTRUCTION II00040.

DIFFUSER SECTION LENGTH CLIP QTY.≤ 24" 4

24" ≤ 48" 648" ≤ 72" 872" ≤ 96" 10

96" ≤ 120" 12

REVERSIBLE DRYWALL MOUNTING CLIP QUANTITY:

OF REV.SHEET 2 2 0

CFINSTALLATION

INSTRUCTIONS

TYPE MP-DR MOUNTING

II00061

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOWTYPE MP-DR MOUNTING

2018/01/03

STEP 5:INSTALL DRYWALL BY SLIDING BEHIND DIFFUSER FACE AND FASTENING TO CEILING FRAMING. FOR EASIEST INSTALLATION, SLIDE TAPERED EDGE OFSHEET BEHIND DIFFUSER FACE.

PARTS LIST:

DESCRIPTION PART NUMBER

Y-END SPLICE PLATE 255152-001

REVERSIBLE DRYWALL MOUNTING CLIP

255149-001

STEP 6:FINISH AND PAINT DRYWALL. IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTION II00030.

STEP 7:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATION INSTRUCTION II00040.

DIFFUSER SECTION LENGTH CLIP QTY.≤ 24" 4

24" ≤ 48" 648" ≤ 72" 872" ≤ 96" 10

96" ≤ 120" 12

REVERSIBLE DRYWALL MOUNTING CLIP QUANTITY:

OF REV.SHEET 1 2 0

CFINSTALLATION

INSTRUCTIONS

TYPE MP-DR MOUNTING

II00061

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOWTYPE MP-DR MOUNTING

2018/01/03

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP,UP, UPL, OR FIELD BUILD PLENUM. SECURE PLENUM TOFRAMING OR HANG FROM STRUCTURE AS REQUIRED BYLOCAL BUILDING CODE. PLENUM MUST BE INSTALLEDFLUSH TO FRAMING.

STEP 4:IF DIFFUSER IS MULTIPLE SECTIONS IN LENGTH, CONTINUE INSTALLING SECTIONS WHILE ALIGNING SECTIONS USING Y-END SPLICE PLATES.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSH TO FRAMING(PLENUM EDGE MAY BE HEMMED OR FLAT)

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'MP-DR' MOUNTING (REVERSIBLE DRYWALL MOUNTING CLIP). DIFFUSER INSTALLATION IS TO BE DONE PRIOR TO DRYWALLINSTALLATION.

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

STEP 3:SCREW DRYWALL MOUNTING CLIPS TO FRAMING. MOUNTING CLIPS SHOULD BELOCATED AT LEAST EVERY 24" (610). CLIPS MAY BE REVERSED TO ALLOW FOREITHER 5/8" (16) OR 1/2" (13) DRYWALL.

2X Y-ENDSPLICE PLATE

USE THIS ORIENTATIONFOR 5/8" DRYWALL

USE THIS ORIENTATIONFOR 1/2" DRYWALL

OF REV.SHEET 1 2 0

CFINSTALLATION

INSTRUCTIONS

TYPE MP-DR MOUNTING

II00061

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOWTYPE MP-DR MOUNTING

2018/01/03

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP,UP, UPL, OR FIELD BUILD PLENUM. SECURE PLENUM TOFRAMING OR HANG FROM STRUCTURE AS REQUIRED BYLOCAL BUILDING CODE. PLENUM MUST BE INSTALLEDFLUSH TO FRAMING.

STEP 4:IF DIFFUSER IS MULTIPLE SECTIONS IN LENGTH, CONTINUE INSTALLING SECTIONS WHILE ALIGNING SECTIONS USING Y-END SPLICE PLATES.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSH TO FRAMING(PLENUM EDGE MAY BE HEMMED OR FLAT)

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'MP-DR' MOUNTING (REVERSIBLE DRYWALL MOUNTING CLIP). DIFFUSER INSTALLATION IS TO BE DONE PRIOR TO DRYWALLINSTALLATION.

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

STEP 3:SCREW DRYWALL MOUNTING CLIPS TO FRAMING. MOUNTING CLIPS SHOULD BELOCATED AT LEAST EVERY 24" (610). CLIPS MAY BE REVERSED TO ALLOW FOREITHER 5/8" (16) OR 1/2" (13) DRYWALL.

2X Y-ENDSPLICE PLATE

USE THIS ORIENTATIONFOR 5/8" DRYWALL

USE THIS ORIENTATIONFOR 1/2" DRYWALL

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

OF REV.SHEET 1 1 0

MPCFIELD INSTALLATION

INSTRUCTIONSIIxxxxx

© Copyright PRICE INDUSTRIES 2011

Installation InstructionsTITLE

2009/mm/dd

OF REV.SHEET 1 1 0

MPCFIELD INSTALLATION

INSTRUCTIONSIIxxxxx

© Copyright PRICE INDUSTRIES 2011

Installation InstructionsTITLE

2009/mm/dd

USE THIS ORIENTATION FOR 5/8” DRYWALL

USE THIS ORIENTATION FOR 1/2” DRYWALL

Page 9: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

7priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (SURFACE MOUNT DRYWALL APPLICATIONS)

Type A Mouting (Countersunk Holes)Available frame styles: CMF

Sample line string: CF//I/IN//AS/1/48.000/1/SS//SM///CMF/XX///A///DPC///BFR//////B12

STEP 1: Frame ceiling opening. Refer to chart for recommended opening width dimension. If no plenum is used, opening width may be additionally reduced by up to 1/4” (6 mm).

STEP 2: Install plenum (if required). Use price model CFP, UP, UPL, or field built plenum. Secure plenum to framing or hang from structure as required by local building code. Plenum may be installed flush to framing, or located to be flush with finished drywall.

STEP 3: Install drywall. For best finish, use tapered edges of drywall around opening. Do not finish drywall until after installing diffuser.

STEP 4: Install diffuser into opening using drywall screws.

Slot Size Slot QTY. Opening Width

1” (25 mm)1 3 3/8” (86 mm)

2 5 11/16” (144 mm)

1 1⁄2” (38 mm)1 4 3/8” (111 mm)

2 7 11/16” (195 mm)

2” (51 mm)1 5 3/8” (137 mm)

2 9 11/16” (246 mm)

2 1⁄2” (64 mm)1 6 3/8" (162 mm)

2 11 11/16” (297 mm)

3” (76 mm)1 7 3/8” (187 mm)

2 13 11/16” (348 mm)

OF REV.SHEET 1 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'C' MOUNTING (CONCEALED MOUNTING BRACKETS).

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP, UP, UPL, OR FIELD BUILD PLENUM WITH HEMMED EDGES. SECURE PLENUM TO FRAMING ORHANG FROM STRUCTURE AS REQUIRED BY LOCAL BUILDING CODE. PLENUM MAY BE INSTALLED FLUSH TO FRAMING, OR LOCATED TO BE FLUSH WITHFINISHED DRYWALL.

STEP 3:INSTALL DRYWALL. IF USING FRAME STYLE EF, FINISH DRYWALL AND PAINT. IF USING FRAME STYLE CMF, DO NOT FINISH DRYWALL UNTIL AFTERINSTALLING DIFFUSER.

IF NO PLENUM IS BEING USED, A LEDGE MAY BE ADDED FOR INSTALLING BRACKET. THIS MAY BE FORMED BY THE DRYWALL, A SHEET METAL HEM ORANGLE, OR METAL STUD FRAMING. IF NO LEDGE IS INSTALLED, BRACKET MAY ALSO BE SCREWED IN PLACE.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSHTO DRYWALL SURFACE

PLENUM EDGE FLUSHTO FRAMING

OF REV.SHEET 1 2 0

CFINSTALLATION

INSTRUCTIONS

TYPE MP-DR MOUNTING

II00061

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOWTYPE MP-DR MOUNTING

2018/01/03

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP,UP, UPL, OR FIELD BUILD PLENUM. SECURE PLENUM TOFRAMING OR HANG FROM STRUCTURE AS REQUIRED BYLOCAL BUILDING CODE. PLENUM MUST BE INSTALLEDFLUSH TO FRAMING.

STEP 4:IF DIFFUSER IS MULTIPLE SECTIONS IN LENGTH, CONTINUE INSTALLING SECTIONS WHILE ALIGNING SECTIONS USING Y-END SPLICE PLATES.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSH TO FRAMING(PLENUM EDGE MAY BE HEMMED OR FLAT)

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) AND CMF (CONCEALED MUDFRAME), AND WITH TYPE 'MP-DR' MOUNTING (REVERSIBLE DRYWALL MOUNTING CLIP). DIFFUSER INSTALLATION IS TO BE DONE PRIOR TO DRYWALLINSTALLATION.

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING FOR FRAME STYLE CMF, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

STEP 3:SCREW DRYWALL MOUNTING CLIPS TO FRAMING. MOUNTING CLIPS SHOULD BELOCATED AT LEAST EVERY 24" (610). CLIPS MAY BE REVERSED TO ALLOW FOREITHER 5/8" (16) OR 1/2" (13) DRYWALL.

2X Y-ENDSPLICE PLATE

USE THIS ORIENTATIONFOR 5/8" DRYWALL

USE THIS ORIENTATIONFOR 1/2" DRYWALL

OF REV.SHEET 1 2 0

CFINSTALLATION

INSTRUCTIONS

TYPE A MOUNTING

II00062

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE A MOUNTING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES CMF (CONCEALED MUD FRAME), AND WITH TYPE 'A'MOUNTING (COUNTERSUNK SCREW HOLES).

FOR INSTRUCTIONS ON COMPLETING DRYWALL TAPING AFTER INSTALLING DIFFUSER, SEE INSTALLATION INSTRUCTION II00030.

STEP 1:FRAME CEILING OPENING. REFER TO CHART FOR RECOMMENDED OPENING WIDTH DIMENSION.

SLOT SIZE SLOT QTY.1212121212

7 3⁄8" (187)13 11⁄16" (348)

3" (76)

OPENING WIDTH

1" (25)

1 1⁄2" (38)

2" (51)

2 1⁄2" (64)

3 3⁄8" (86)5 11⁄16" (144)4 3⁄8" (111)

7 11⁄16" (195)5 3⁄8" (137)

9 11⁄16" (246)6 3⁄8" (162)

11 11⁄16" (297)

STEP 2:INSTALL PLENUM (IF REQUIRED). USE PRICE MODEL CFP, UP, UPL, OR FIELD BUILD PLENUM. SECURE PLENUM TO FRAMING OR HANG FROM STRUCTUREAS REQUIRED BY LOCAL BUILDING CODE. PLENUM MAY BE INSTALLED FLUSH TO FRAMING, OR LOCATED TO BE FLUSH WITH FINISHED DRYWALL.

STEP 3:INSTALL DRYWALL. FOR BEST FINISH, USE TAPERED EDGES OF DRYWALL AROUND OPENING. DO NOT FINISH DRYWALL UNTIL AFTER INSTALLINGDIFFUSER.

OPENING LENGTH = NOMINAL SIZE

OPENINGWIDTH

PLENUM EDGE FLUSH TO DRYWALL SURFACE(PLENUM EDGE MAY BE HEMMED OR FLAT)

PLENUM EDGE FLUSH TO FRAMING(PLENUM EDGE MAY BE HEMMED OR FLAT)

OF REV.SHEET 2 2 0

CFINSTALLATION

INSTRUCTIONS

TYPE A MOUNTING

II00062

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE A MOUNTING

2018/01/03

STEP 4:INSTALL DIFFUSER INTO CEILING USING DRYWALL SCREWS.

STEP 5:IF DIFFUSER IS MULTIPLE SECTIONS IN LENGTH, CONTINUE INSTALLING SECTIONS WHILE ALIGNING SECTIONS USING Y-END SPLICE PLATES.

2X Y-ENDSPLICE PLATE

STEP 6:FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTION II00030.

STEP7:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATION INSTRUCTION II00040.

PARTS LIST:

DESCRIPTION PART NUMBERY-END SPLICE PLATE 255152-001

OF REV.SHEET 2 2 0

CFINSTALLATION

INSTRUCTIONS

TYPE A MOUNTING

II00062

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE A MOUNTING

2018/01/03

STEP 4:INSTALL DIFFUSER INTO CEILING USING DRYWALL SCREWS.

STEP 5:IF DIFFUSER IS MULTIPLE SECTIONS IN LENGTH, CONTINUE INSTALLING SECTIONS WHILE ALIGNING SECTIONS USING Y-END SPLICE PLATES.

2X Y-ENDSPLICE PLATE

STEP 6:FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTION II00030.

STEP7:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATION INSTRUCTION II00040.

PARTS LIST:

DESCRIPTION PART NUMBERY-END SPLICE PLATE 255152-001

Page 10: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

8 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (SURFACE MOUNT DRYWALL APPLICATIONS)

STEP 5: If diffuser is multiple sections in length, continue installing sections while aligning sections using Y-end splice plates.

STEP 6: Finish drywall as per page 9.

STEP 7: Adjust pattern controllers for desired air pattern as per page 14 & 15.

OF REV.SHEET 2 3 0

CFINSTALLATION

INSTRUCTIONS

TYPE C MOUNTING

II00060

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

TYPE C MOUNTING

2018/01/03

STEP 4:PREPARE BRACKETS BY INSERTING ONE SCREW THROUGH EACHINNER BRACKET, AND PUSHING RUBBER GROMMET DOWN SHAFT OFSCREW. OUTER BRACKET

STEP 5:THREAD OUTER BRACKETS ABOUT 1/4" (6) ONTO SCREWS.

INNER BRACKET

STEP 6:INSTALL BRACKETS ONTO DIFFUSER. DEFLECT SIDE FRAMES AND SNAP BRACKETS UNDER DIFFUSER FRAME. BRACKETS ARE REQUIREDAPPROXIMATELY EVERY 36" (914) TO 48" (1219), WITH ONE ON EACH END. ENSURE THAT PATTERN CONTROLLERS ARE POSITIONED TO THE SIDESO THAT SCREW MAY BE ACCESSED THROUGH DIFFUSER SLOT.

STEP 7:POSITION DIFFUSER IN CEILING. USING A SCREWDRIVER, PUSH UPWARD ON SCREW UNTIL BRACKET SNAPS INTO PLACE. IF DIFFUSER IS MULTIPLESECTIONS IN LENGTH, ALIGN SECTIONS USING Y-END SPLICE PLATES. TIGHTEN SCREWS UNTIL FRAME IS FLUSH WITH THE CEILING.

1 SLOT 2 SLOT

2X Y-ENDSPLICE PLATE

STEP 8:IF USING FRAME STYLE CMF, FINISH DRYWALL CEILING AS PER INSTALLATION INSTRUCTIONII00065.

STEP 9:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATIONINSTRUCTION II00064.

Page 11: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

9priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (SURFACE MOUNT DRYWALL APPLICATIONS)

Drywall Finishing for CMF FrameAvailable frame styles: CMF

Sample line string: CF//I/IN//AS/1/48.000/1/SS//SM///CMF/XX///C///DPC///BFR//////B12

NOTE: Before finishing drywall, install CF diffuser. For installation of CF diffusers:

· See page 2 (C mounting)

· See page 5 (MP-DR mounting)

· See page 7 (A mounting)

STEP 1: Thoroughly clean diffuser flanges to remove any oils or residue from surface.

STEP 2: Apply one coat of bonding agent over entire surface of flange, and allow to dry as per manufacturer’s instructions.

STEP 3: Apply one coat of drywall compound on diffuser flanges and approximately 3” (76 mm) onto drywall beyond flange.

STEP 4: Apply a 4” (102 mm) wide mesh or paper tape to joint compound. Be sure to smooth out and remove air pockets. Mesh or tape should cover diffuser flange, but not extend onto inside vertical edge of diffuser frame. Apply second coat of drywall compound over tape and smooth. Allow to dry.

STEP 5: Apply at least two coats of finishing compound. Allow to dry. Afterwards, sand smooth, prime, and paint surface.

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

MUD-IN FRAME

II00065

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

MUD-IN FRAME

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO FINISHING DRYWALL AFTER INSTALLING CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) WITH FRAME STYLE CMF(CONCEALED MUD FRAME).

BEFORE FINISHING DRYWALL, INSTALL CF DIFFUSER. FOR INSTALLATION OF CF DIFFUSERS:• SEE INSTALLATION INSTRUCTION II00060 (C MOUNTING)• SEE INSTALLATION INSTRUCTION II00061 (MP-DR MOUNTING)• SEE INSTALLATION INSTRUCTION II00062 (A MOUNTING)

STEP 1:THOROUGHLY CLEAN DIFFUSER FLANGES TO REMOVE ANY OILS OR RESIDUE FROM SURFACE.

STEP 2:APPLY ONE COAT OF BONDING AGENT OVER ENTIRE SURFACE OF FLANGE, AND ALLOW TO DRY AS PER MANUFACTURER'S INSTRUCTIONS.

STEP 3:APPLY ONE COAT OF DRYWALL COMPOUND ON DIFFUSER FLANGES AND APPROXIMATELY 3" (76) ONTO DRYWALL BEYOND FLANGE.

STEP 4:APPLY A 4" (102) WIDE MESH OR PAPER TAPE TO JOINT COMPOUND. BE SURE TO SMOOTH OUT AND REMOVE AIR POCKETS. MESH OR TAPE SHOULDCOVER DIFFUSER FLANGE, BUT NOT EXTEND ONTO INSIDE VERTICAL EDGE OF DIFFUSER FRAME. APPLY SECOND COAT OF DRYWALL COMPOUND OVERTAPE AND SMOOTH. ALLOW TO DRY.

STEP 5:APPLY AT LEAST TWO COATS OF FINISHING COMPOUND. ALLOW TO DRY. AFTERWARDS, SAND SMOOTH, PRIME, AND PAINT SURFACE.

BONDING AGENT

ONE COATDRYWALL COMPOUND

MESH OR DRYWALL TAPE

TOP COAT LAYERSDRYWALL COMPOUND

FRAME CONCEALED BYDRYWALL COMPOUND

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

MUD-IN FRAME

II00065

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

MUD-IN FRAME

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO FINISHING DRYWALL AFTER INSTALLING CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) WITH FRAME STYLE CMF(CONCEALED MUD FRAME).

BEFORE FINISHING DRYWALL, INSTALL CF DIFFUSER. FOR INSTALLATION OF CF DIFFUSERS:• SEE INSTALLATION INSTRUCTION II00060 (C MOUNTING)• SEE INSTALLATION INSTRUCTION II00061 (MP-DR MOUNTING)• SEE INSTALLATION INSTRUCTION II00062 (A MOUNTING)

STEP 1:THOROUGHLY CLEAN DIFFUSER FLANGES TO REMOVE ANY OILS OR RESIDUE FROM SURFACE.

STEP 2:APPLY ONE COAT OF BONDING AGENT OVER ENTIRE SURFACE OF FLANGE, AND ALLOW TO DRY AS PER MANUFACTURER'S INSTRUCTIONS.

STEP 3:APPLY ONE COAT OF DRYWALL COMPOUND ON DIFFUSER FLANGES AND APPROXIMATELY 3" (76) ONTO DRYWALL BEYOND FLANGE.

STEP 4:APPLY A 4" (102) WIDE MESH OR PAPER TAPE TO JOINT COMPOUND. BE SURE TO SMOOTH OUT AND REMOVE AIR POCKETS. MESH OR TAPE SHOULDCOVER DIFFUSER FLANGE, BUT NOT EXTEND ONTO INSIDE VERTICAL EDGE OF DIFFUSER FRAME. APPLY SECOND COAT OF DRYWALL COMPOUND OVERTAPE AND SMOOTH. ALLOW TO DRY.

STEP 5:APPLY AT LEAST TWO COATS OF FINISHING COMPOUND. ALLOW TO DRY. AFTERWARDS, SAND SMOOTH, PRIME, AND PAINT SURFACE.

BONDING AGENT

ONE COATDRYWALL COMPOUND

MESH OR DRYWALL TAPE

TOP COAT LAYERSDRYWALL COMPOUND

FRAME CONCEALED BYDRYWALL COMPOUND

Page 12: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

10 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (TEE BAR LAY-IN APPLICATIONS)

This section applies to Custom Flow linear diffusers (model CF) for installation in continuous runs in suspended tee bar ceiling applications (LI application).

Sample line string: CF//I/IN//AS/1/48.000/1/SS//LI///EF/XX///HB///DPC///BFR//////B12

General InstallationSTEP 1: Refer to Factory Label to determine the diffuser has been ordered with the hanger bracket option.

Sample line string: CF//I/IN//AS/1/48.000/1/SS//LI///EF/XX///HB///DPC///BFR//////B12

If hanger bracket option has been ordered, ensure that the correct number of hanger has been shipped using the following table as reference.

STEP 2: Install perimeter wall angle for ceiling system. Main and cross tee installation may also proceed, except for any cross tees that will rest on the back of diffuser face.

STEP 3: Install plenum (if required) to diffuser using sheet metal screws as shown. Space sheet metal screws approximately every 12” (305 mm). This step may be skipped, but is recommended to be completed first.

STEP 4: Determine preferred type of installation. Diffuser may be installed by suspending from ceiling structure using hanger wire or by resting on top of T-bar. For suspended ceiling installation, proceed to STEP 5A. For resting on top of T-bar, proceed to STEP 5B.

Diffuser Section Length Kit QTY.

Nom. Length ≤ 24” 2

24” < Nom. Length ≤ 48” 2

48" < Nom. Length ≤ 72" 3

72" < Nom. Length ≤ 96" 3

96” < Nom. Length ≤ 120” 4

OF REV.SHEET 1 2 0

CFINSTALLATION

INSTRUCTIONS

LI APPLICATION

II00063

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

LI APPLICATION

2018/01/03

STEP 2:INSTALL PLENUM (IF REQUIRED) TO DIFFUSER USING SHEET METAL SCREWS AS SHOWN. SPACE SHEET METAL SCREWS APPROXIMATELY EVERY 12" (305).

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) FOR INSTALLATION INCONTINUOUS RUNS IN SUSPENDED T-BAR CEILING APPLICATIONS (LI APPLICATION).

STEP 1:INSTALL PERIMETER WALL ANGLE FOR CEILING SYSTEM. MAIN AND CROSS TEE INSTALLATION MAY ALSO PROCEED, EXCEPT FOR ANY CROSS TEES THATWILL REST ON THE BACK OF DIFFUSER FACE.

STEP 3A:SUSPEND DIFFUSER/PLENUM SECTIONS USING HANGER WIRE THROUGH HANGER BRACKETS OR THROUGH HANGER HOLES ON TOP OF PLENUM. HANGARBRACKETS SHOULD BE LOCATED AT LEAST EVERY 24" (610).IF DIFFUSER IS MULTIPLE SECTIONS IN LENGTH, CONTINUE INSTALLING SECTIONS WHILE ALIGNING SECTIONS USING Y-END SPLICE PLATES.

ENSURE TO ADJUST HANGER WIRES TO MAKE DIFFUSERS HANG LEVEL.

2X Y-ENDSPLICE PLATE

2X Y-ENDSPLICE PLATE

PERIMETERWALL ANGLE

HANGER WIRE

HANGER BRACKETS

Page 13: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

11priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWINSTALLATION & MOUNTING INSTRUCTIONS (TEE BAR LAY-IN APPLICATIONS)

STEP 5A: Suspend diffuser/plenum sections using hanger wire through hanger brackets or through hanger holes on top of plenum. Alternatively, if no hanger brackets have been ordered, sheet metal screws may be drilled into diffuser side frame. Hanger brackets/screws should be located at least every 24” (610 mm). Screw hanger brackets in place using sheet metal screws in order to prevent shifting. If diffuser is multiple sections in length, continue installing sections while aligning sections using Y-end splice plates. Ensure to adjust hanger wires to make diffusers hang level.

STEP 5B: Install two main tees to run along either side of diffuser and drop diffuser in place.

STEP 6: Attach plenum to diffuser if not already done so. Hang or secure plenum to structure as required by local building codes.

STEP 7: Complete T-bar installation. Cross tees may rest on diffuser flange, or cut flush and attached using sheet metal angles, as shown.

STEP 8: Install ceiling tiles.

STEP 9: Adjust pattern controllers for desired air pattern as per page 14 & 15.

OF REV.SHEET 1 2 0

CFINSTALLATION

INSTRUCTIONS

LI APPLICATION

II00063

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

LI APPLICATION

2018/01/03

STEP 2:INSTALL PLENUM (IF REQUIRED) TO DIFFUSER USING SHEET METAL SCREWS AS SHOWN. SPACE SHEET METAL SCREWS APPROXIMATELY EVERY 12" (305).

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) FOR INSTALLATION INCONTINUOUS RUNS IN SUSPENDED T-BAR CEILING APPLICATIONS (LI APPLICATION).

STEP 1:INSTALL PERIMETER WALL ANGLE FOR CEILING SYSTEM. MAIN AND CROSS TEE INSTALLATION MAY ALSO PROCEED, EXCEPT FOR ANY CROSS TEES THATWILL REST ON THE BACK OF DIFFUSER FACE.

STEP 3A:SUSPEND DIFFUSER/PLENUM SECTIONS USING HANGER WIRE THROUGH HANGER BRACKETS OR THROUGH HANGER HOLES ON TOP OF PLENUM. HANGARBRACKETS SHOULD BE LOCATED AT LEAST EVERY 24" (610).IF DIFFUSER IS MULTIPLE SECTIONS IN LENGTH, CONTINUE INSTALLING SECTIONS WHILE ALIGNING SECTIONS USING Y-END SPLICE PLATES.

ENSURE TO ADJUST HANGER WIRES TO MAKE DIFFUSERS HANG LEVEL.

2X Y-ENDSPLICE PLATE

2X Y-ENDSPLICE PLATE

PERIMETERWALL ANGLE

HANGER WIRE

HANGER BRACKETS

OF REV.SHEET 1 2 0

CFINSTALLATION

INSTRUCTIONS

LI APPLICATION

II00063

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

LI APPLICATION

2018/01/03

STEP 2:INSTALL PLENUM (IF REQUIRED) TO DIFFUSER USING SHEET METAL SCREWS AS SHOWN. SPACE SHEET METAL SCREWS APPROXIMATELY EVERY 12" (305).

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF), WITH FRAME STYLES EF (EXPOSED FRAME) FOR INSTALLATION INCONTINUOUS RUNS IN SUSPENDED T-BAR CEILING APPLICATIONS (LI APPLICATION).

STEP 1:INSTALL PERIMETER WALL ANGLE FOR CEILING SYSTEM. MAIN AND CROSS TEE INSTALLATION MAY ALSO PROCEED, EXCEPT FOR ANY CROSS TEES THATWILL REST ON THE BACK OF DIFFUSER FACE.

STEP 3A:SUSPEND DIFFUSER/PLENUM SECTIONS USING HANGER WIRE THROUGH HANGER BRACKETS OR THROUGH HANGER HOLES ON TOP OF PLENUM. HANGARBRACKETS SHOULD BE LOCATED AT LEAST EVERY 24" (610).IF DIFFUSER IS MULTIPLE SECTIONS IN LENGTH, CONTINUE INSTALLING SECTIONS WHILE ALIGNING SECTIONS USING Y-END SPLICE PLATES.

ENSURE TO ADJUST HANGER WIRES TO MAKE DIFFUSERS HANG LEVEL.

2X Y-ENDSPLICE PLATE

2X Y-ENDSPLICE PLATE

PERIMETERWALL ANGLE

HANGER WIRE

HANGER BRACKETS

OF REV.SHEET 2 2 0

CFINSTALLATION

INSTRUCTIONS

LI APPLICATION

II00063

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

LI APPLICATION

2018/01/03

PARTS LIST:

DESCRIPTION PART NUMBERHANGER BRACKET 269639-001

Y-END SPLICE PLATE 255152-001

DIFFUSER SECTION LENGTH BRACKET QTY.≤ 24" 4

24" ≤ 48" 648" ≤ 72" 872" ≤ 96" 10

96" ≤ 120" 12

HANGER BRACKET QUANTITY:

STEP 3B:DIFFUSER CAN ALSO BE INSTALLED BY RESTING IT ON TWO TEES RUNNING ON EITHER SIDE OF DIFFUSER.

STEP 4:ATTACH PLENUM TO DIFFUSER IF NOT ALREADY DONE SO. HANG OR SECURE PLENUM TO STRUCTURE AS REQUIRED BY LOCAL BUILDING CODES.

STEP 5:COMPLETE T-BAR INSTALLATION. CROSS TEES MAY REST ON DIFFUSER FLANGE, OR CUT FLUSH AND ATTACHED USING SHEET METAL ANGLES, ASSHOWN.

STEP 6:INSTALL CIELING TILES.

STEP 7:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATION INSTRUCTION II00040.

TEE RESTING ONDIFFUSER FLANGE

TEE FLUSH TODIFFUSER FACE

MOUNTING ANGLES (BY OTHERS)FOR FLUSH TEE

TEE RESTING ONDIFFUSER FLANGE

OF REV.SHEET 2 2 0

CFINSTALLATION

INSTRUCTIONS

LI APPLICATION

II00063

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

LI APPLICATION

2018/01/03

PARTS LIST:

DESCRIPTION PART NUMBERHANGER BRACKET 269639-001

Y-END SPLICE PLATE 255152-001

DIFFUSER SECTION LENGTH BRACKET QTY.≤ 24" 4

24" ≤ 48" 648" ≤ 72" 872" ≤ 96" 10

96" ≤ 120" 12

HANGER BRACKET QUANTITY:

STEP 3B:DIFFUSER CAN ALSO BE INSTALLED BY RESTING IT ON TWO TEES RUNNING ON EITHER SIDE OF DIFFUSER.

STEP 4:ATTACH PLENUM TO DIFFUSER IF NOT ALREADY DONE SO. HANG OR SECURE PLENUM TO STRUCTURE AS REQUIRED BY LOCAL BUILDING CODES.

STEP 5:COMPLETE T-BAR INSTALLATION. CROSS TEES MAY REST ON DIFFUSER FLANGE, OR CUT FLUSH AND ATTACHED USING SHEET METAL ANGLES, ASSHOWN.

STEP 6:INSTALL CIELING TILES.

STEP 7:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATION INSTRUCTION II00040.

TEE RESTING ONDIFFUSER FLANGE

TEE FLUSH TODIFFUSER FACE

MOUNTING ANGLES (BY OTHERS)FOR FLUSH TEE

TEE RESTING ONDIFFUSER FLANGE

OF REV.SHEET 2 2 0

CFINSTALLATION

INSTRUCTIONS

LI APPLICATION

II00063

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

LI APPLICATION

2018/01/03

PARTS LIST:

DESCRIPTION PART NUMBERHANGER BRACKET 269639-001

Y-END SPLICE PLATE 255152-001

DIFFUSER SECTION LENGTH BRACKET QTY.≤ 24" 4

24" ≤ 48" 648" ≤ 72" 872" ≤ 96" 10

96" ≤ 120" 12

HANGER BRACKET QUANTITY:

STEP 3B:DIFFUSER CAN ALSO BE INSTALLED BY RESTING IT ON TWO TEES RUNNING ON EITHER SIDE OF DIFFUSER.

STEP 4:ATTACH PLENUM TO DIFFUSER IF NOT ALREADY DONE SO. HANG OR SECURE PLENUM TO STRUCTURE AS REQUIRED BY LOCAL BUILDING CODES.

STEP 5:COMPLETE T-BAR INSTALLATION. CROSS TEES MAY REST ON DIFFUSER FLANGE, OR CUT FLUSH AND ATTACHED USING SHEET METAL ANGLES, ASSHOWN.

STEP 6:INSTALL CIELING TILES.

STEP 7:ADJUST PATTERN CONTROLLERS FOR DESIRED AIR PATTERN AS PER INSTALLATION INSTRUCTION II00040.

TEE RESTING ONDIFFUSER FLANGE

TEE FLUSH TODIFFUSER FACE

MOUNTING ANGLES (BY OTHERS)FOR FLUSH TEE

TEE RESTING ONDIFFUSER FLANGE

TEE FLUSH TO DIFFUSER FACE

TEE RESTING ON DIFFUSER FLANGE

Page 14: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

12 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWFIELD TRIMMING

Available end conditions: W, Y, Z

Sample line string: CF//I/IN//AS/1/48.000/1/SS//SM///EF/WW///HB///DPC///BFR//////B12

NOTE: Trimming of XX (mitered) end conditions is not recommended. Field trimming on multiple section units with mitered ends may be accomplished by trimming open end.

STEP 1: Remove endcap, if installed.

STEP 2: Pull out locking pins from slots of lower spacer bar. Slide out upper spacer bar.

STEP 3: Remove pattern controllers and lower spacer bar.

STEP 4: Cut frames to length, making sure cut is clean and square. Care should be taken not to chip paint when cutting. Spacer bars may be reinstalled to support frames while cutting.

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

FIELD TRIMMING

II00059

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

FIELD TRIMMING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF). FIELD TRIMMING OF X-X (MITRED) END CONDITIONS IS NOT RECOMMENDED.FIELD TRIMMING ON MULTIPLE SECTION UNITS WITH MITRED ENDS MAY BE ACCOMPLISHED BY TRIMMING OPEN END.

STEP 4:CUT FRAMES TO LENGTH, MAKING SURE CUT IS CLEAN ANDSQUARE. CARE SHOULD BE TAKEN NOT TO CHIP PAINT WHENCUTTING. SPACER BARS MAY BE REINSTALLED TO SUPPORTFRAMES WHILE CUTTING.

STEP 5:CAREFULLY TRIM PATTERN CONTROL BLADES TO LENGTH USINGTIN SNIPS, AND NOTCH FLANGES 11/16" (17), AS SHOWN.

STEP 6:REPLACE LOWER SPACER BAR AND PATTERN CONTROLLERS.SLIDE UPPER SPACER BAR ON TOP OF PATTERN CONTROLLERSAND RE-INSERT LOCKING PINS INTO SLOTS OF LOWER SPACERBAR.

STEP 7:REINSTALL ENDCAPS, IF NECESSARY, AND CONTINUEINSTALLATION OF DIFFUSER AS REQUIRED. ADJUST BLADES FORDESIRED AIR DISCHARGE PATTERN, AS PER INSTALLATIONINSTRUCTION II00040.

UPPER SPACER BAR

LOWER SPACER BAR

LOCKING PINS

CUT FRAMES TO LENGTH

TRIM PATTERN CONTROLLERS

NOTCH

STEP 1:REMOVE ENDCAP, IF INSTALLED.

STEP 2:PULL OUT LOCKING PINS FROM SLOTS OF LOWER SPACER BAR.SLIDE OUT UPPER SPACER BAR.

STEP 3:REMOVE PATTERN CONTROLLERS AND LOWER SPACER BAR.

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

FIELD TRIMMING

II00059

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

FIELD TRIMMING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF). FIELD TRIMMING OF X-X (MITRED) END CONDITIONS IS NOT RECOMMENDED.FIELD TRIMMING ON MULTIPLE SECTION UNITS WITH MITRED ENDS MAY BE ACCOMPLISHED BY TRIMMING OPEN END.

STEP 4:CUT FRAMES TO LENGTH, MAKING SURE CUT IS CLEAN ANDSQUARE. CARE SHOULD BE TAKEN NOT TO CHIP PAINT WHENCUTTING. SPACER BARS MAY BE REINSTALLED TO SUPPORTFRAMES WHILE CUTTING.

STEP 5:CAREFULLY TRIM PATTERN CONTROL BLADES TO LENGTH USINGTIN SNIPS, AND NOTCH FLANGES 11/16" (17), AS SHOWN.

STEP 6:REPLACE LOWER SPACER BAR AND PATTERN CONTROLLERS.SLIDE UPPER SPACER BAR ON TOP OF PATTERN CONTROLLERSAND RE-INSERT LOCKING PINS INTO SLOTS OF LOWER SPACERBAR.

STEP 7:REINSTALL ENDCAPS, IF NECESSARY, AND CONTINUEINSTALLATION OF DIFFUSER AS REQUIRED. ADJUST BLADES FORDESIRED AIR DISCHARGE PATTERN, AS PER INSTALLATIONINSTRUCTION II00040.

UPPER SPACER BAR

LOWER SPACER BAR

LOCKING PINS

CUT FRAMES TO LENGTH

TRIM PATTERN CONTROLLERS

NOTCH

STEP 1:REMOVE ENDCAP, IF INSTALLED.

STEP 2:PULL OUT LOCKING PINS FROM SLOTS OF LOWER SPACER BAR.SLIDE OUT UPPER SPACER BAR.

STEP 3:REMOVE PATTERN CONTROLLERS AND LOWER SPACER BAR.

Page 15: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

13priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWFIELD TRIMMING

STEP 5: Carefully trim pattern control blades to length using tin snips, and notch flanges 11/16” (17 mm), as shown.

STEP 6: Replace lower spacer bar and pattern controllers. Slide upper spacer bar on top of pattern controllers and re-insert locking pins into slots of lower spacer bar.

STEP 7: Reinstall endcaps, if necessary, and continue installation of diffuser as required.

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

FIELD TRIMMING

II00059

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

FIELD TRIMMING

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF). FIELD TRIMMING OF X-X (MITRED) END CONDITIONS IS NOT RECOMMENDED.FIELD TRIMMING ON MULTIPLE SECTION UNITS WITH MITRED ENDS MAY BE ACCOMPLISHED BY TRIMMING OPEN END.

STEP 4:CUT FRAMES TO LENGTH, MAKING SURE CUT IS CLEAN ANDSQUARE. CARE SHOULD BE TAKEN NOT TO CHIP PAINT WHENCUTTING. SPACER BARS MAY BE REINSTALLED TO SUPPORTFRAMES WHILE CUTTING.

STEP 5:CAREFULLY TRIM PATTERN CONTROL BLADES TO LENGTH USINGTIN SNIPS, AND NOTCH FLANGES 11/16" (17), AS SHOWN.

STEP 6:REPLACE LOWER SPACER BAR AND PATTERN CONTROLLERS.SLIDE UPPER SPACER BAR ON TOP OF PATTERN CONTROLLERSAND RE-INSERT LOCKING PINS INTO SLOTS OF LOWER SPACERBAR.

STEP 7:REINSTALL ENDCAPS, IF NECESSARY, AND CONTINUEINSTALLATION OF DIFFUSER AS REQUIRED. ADJUST BLADES FORDESIRED AIR DISCHARGE PATTERN, AS PER INSTALLATIONINSTRUCTION II00040.

UPPER SPACER BAR

LOWER SPACER BAR

LOCKING PINS

CUT FRAMES TO LENGTH

TRIM PATTERN CONTROLLERS

NOTCH

STEP 1:REMOVE ENDCAP, IF INSTALLED.

STEP 2:PULL OUT LOCKING PINS FROM SLOTS OF LOWER SPACER BAR.SLIDE OUT UPPER SPACER BAR.

STEP 3:REMOVE PATTERN CONTROLLERS AND LOWER SPACER BAR.

Page 16: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

14 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWPATTERN CONTROLLER ADJUSTMENT

In order to achieve desired pattern and volume adjustment, adjust pattern controllers accordingly.

NOTE: Pattern controllers must be dampered slightly in order to achieve horizontal pattern in 2 slot configurations.

Volume Adjustment

Fully open

Partially dampered

Shutoff

AS JS

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

Page 17: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

15priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWPATTERN CONTROLLER ADJUSTMENT

ADJUSTA-SLOT (AS) PATTERN ADJUSTMENT

JET-SLOT (JS) PATTERN ADJUSTMENT

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULARHORIZONTALVERTICAL

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULARHORIZONTALVERTICAL

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULARHORIZONTALVERTICAL

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULARHORIZONTALVERTICAL

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULARHORIZONTALVERTICAL

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

OF REV.SHEET 1 1 0

CFINSTALLATION

INSTRUCTIONS

PATTERN CONTROLLER

ADJUSTMENT

II00064

© Copyright PRICE INDUSTRIES 2018

Installation InstructionsCF - CUSTOM FLOW

PATTERN CONTROLLER ADJUSTMENT

2018/01/03

ALWAYS READ & UNDERSTAND ALL INSTALLATION INSTRUCTIONS PRIOR TO STARTING.

THIS INSTRUCTION APPLIES TO CUSTOM FLOW LINEAR DIFFUSERS (MODEL CF) FOR BOTH AS (ADJUSTA-SLOT) AND JS (JET-SLOT) SERIES OF PATTERNCONTROLLERS. IN ORDER TO ACHIEVE DESIRED PATTERN AND VOLUME ADJUSTMENT, ADJUST PATTERN CONTROLLERS ACCORDINGLY.

VOLUME ADJUSTMENTS:

• FULLY OPEN:

• PARTIALLY DAMPERED:

• SHUTOFF:

AS JS

OPPOSED HORIZONTALHORIZONTAL & VERTICAL

HORIZONTAL & VERTICALOPPOSED HORIZONTAL

ANGULAR

HORIZONTAL

AS PATTERN ADJUSTMENTS:

JS PATTERN ADJUSTMENTS:

VERTICAL ANGULAR

NOTE:

PATTERN CONTROLLERS MUST BE DAMPERED SLIGHTLY IN ORDER TO ACHIEVE HORIZONTALPATTERN IN 2 SLOT CONFIGURATIONS.

HORIZONTALVERTICAL

HORIZONTAL

VERTICAL

VERTICAL

HORIZONTAL

ANGULAR

ANGULAR

OPPOSED HORIZONTAL

OPPOSED HORIZONTAL

HORIZONTAL & VERTICAL

HORIZONTAL & VERTICAL

Page 18: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

16 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWPARTS LIST

Type C Mounting

Each type C mounting bracket kit includes:

Description Slot QTY. Slot Width Part Number

Type C mounting bracket kit

1

1.0” 505737-001

1.5” 505737-002

2.0” 505737-0032.5” 505737-0043.0” 505737-005

2

1.0” 505737-1011.5” 505737-1022.0” 505737-1032.5” 505737-1043.0” 505737-105

Inner bracket ALL

1.0” 267950-0011.5” 267950-0022.0” 267950-0032.5” 267950-0043.0” 267950-005

Outer bracket

1

1.0” 267951-0011.5” 267951-0022.0” 267951-0032.5” 267951-0043.0” 267951-005

2

1.0” 269174-0011.5” 269174-0022.0” 269174-0032.5” 269174-0043.0” 269174-005

Rubber grommet ALL ALL 033363-001#8 x 3” sheet metal screw ALL ALL 031724-001

Slot Size Slot QTY. Slot Width

Inner bracket1 1

2 2

Outer bracket 1 or 2 1

Rubber grommet1 12 2

#8 x 3” sheet metal screw1 12 2

Page 19: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

17priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWPARTS LIST

Type MP-DR Mounting

Accessories

Field Cut Kit

Description Part Number

Reversible drywall mounting clip

255149-001

Description Part Number

Y-end splice plate 255152-001

Description Frame Style Slot QTY. End Condition Slot Width Part Number

CF field cut kit EF

1

Y

1.0” 505776-001

1.5” 505776-002

2.0” 505776-0032.5” 505776-0043.0” 505776-005

W

1.0” 505776-0061.5” 505776-0072.0” 505776-0082.5” 505776-0093.0” 505776-010

Z

1.0” 505776-0111.5” 505776-0122.0” 505776-0132.5” 505776-0143.0” 505776-015

2

Y

1.0” 505776-0161.5” 505776-0172.0” 505776-0182.5” 505776-0193.0” 505776-020

W

1.0” 505776-0211.5” 505776-0222.0” 505776-0232.5” 505776-0243.0” 505776-025

Z

1.0” 505776-0261.5” 505776-0272.0” 505776-0282.5” 505776-0293.0” 505776-030

Page 20: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

18 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWPARTS LIST

Description Frame Style Slot QTY. End Condition Slot Width Part Number

CF field cut kit CMF

1

Y

1.0” 505776-031

1.5” 505776-032

2.0” 505776-0332.5” 505776-0343.0” 505776-035

W

1.0” 505776-0361.5” 505776-0372.0” 505776-0382.5” 505776-0393.0” 505776-040

Z

1.0” 505776-0411.5” 505776-0422.0” 505776-0432.5” 505776-0443.0” 505776-045

2

Y

1.0” 505776-0461.5” 505776-0472.0” 505776-0482.5” 505776-0493.0” 505776-050

W

1.0” 505776-0511.5” 505776-0522.0” 505776-0532.5” 505776-0543.0” 505776-055

Z

1.0” 505776-0561.5” 505776-0572.0” 505776-0582.5” 505776-0593.0” 505776-060

Page 21: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

19priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWNOTES

Page 22: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

20 CUSTOM FLOW - Manual | priceindustries.com

CUSTOM FLOWNOTES

Page 23: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

21priceindustries.com | CUSTOM FLOW - Manual

CUSTOM FLOWNOTES

Page 24: INSTALLATION + SERVICE - priceindustries.com · UP/UPL: Universal plenum available for CF diffusers (low profile option available) ... a sheet metal hem (B) or angle (C), or metal

This document contains the most current product information as of this printing. For the most up-to-date product information, please go to priceindustries.com