Installation Instructions Regolo RM1 Recessed MUDRING CEILING MOUNT NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com February 2019 Page 1 WARNINGS: •Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced. •Risk of electrical shock or fire, disconnect power during installation or servicing. Read all instructions completely before starting installation. Install and wire in accordance to all national and local codes by a certifi ed electrician. Fixture may be sharp, handle with care. Let fixture cool before main- tenance. AVERTISSEMENTS •Risque d’électrocution ou d’incendie. Déconnectez l’alimenta- tion durant l’installation ou la maintenance. Lisez attentivement toutes les instructions avant de commencer toute installation. Faites installer et câbler selon les normes Nationales et Lo- cales par un électricien certifi é. Les installations peuvent être coupantes, à manipuler avec précaution. Laissez refroidir les installations avant une opération de maintenance. ADVERTENCIA Riesgo de descarga eléctrica oun incendio, desconecte la alimentación durante la instalación o servicio. Leer todas las instrucciones completas antes de empesar la instalación. Instalar y cablear en acuerdo a las reglas nacionales y códigos locales por un electricista certifi cado. El accesorio puede estar agudo, agarre con cuidado deje que el acessorio. Enfriar antes de mantenimiento. DISTORT JOINT 1 5 / 8(42 mm) 3 1 / 8” min. (79 mm) 3 3 / 4” max. (95 mm) 4” (102 mm) Top of wiring box 1 5 / 8(42 mm) 3 1 / 8” min. (79 mm) 3 3 / 4” max. (95 mm) 4” (102 mm) Top of wiring box

Transcript of Installation Instructions Regolo RM1 Recessed€¦ · Regolo RM1 Recessed MUDRN CLN MUN NLITE...

Page 1: Installation Instructions Regolo RM1 Recessed€¦ · Regolo RM1 Recessed MUDRN CLN MUN NLITE Lighting Inc. 177 East 51st Avenue Denver, CO 043 Phone (303) 27-646 February 21 Page

Installation InstructionsRegolo RM1 Recessed

MUDRING CEILING MOUNT

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com February 2019

Page 1

WARNINGS:•Do not assemble continuous run on the ground and lift into place. Joints will distort and not create a tight fit. Joining hardware will have to be purchased and replaced.

•Risk of electrical shock or fire, disconnect power during installation or servicing. Read all instructions completely before starting installation. Install and wire in accordance to all national and local codes by a certifi ed electrician. Fixture may be sharp, handle with care. Let fixture cool before main-tenance.

AVERTISSEMENTS •Risque d’électrocution ou d’incendie. Déconnectez l’alimenta-tion durant l’installation ou la maintenance. Lisez attentivement toutes les instructions avant de commencer toute installation. Faites installer et câbler selon les normes Nationales et Lo-cales par un électricien certifi é. Les installations peuvent être coupantes, à manipuler avec précaution. Laissez refroidir les installations avant une opération de maintenance.

ADVERTENCIA Riesgo de descarga eléctrica oun incendio, desconecte la alimentación durante la instalación o servicio. Leer todas las instrucciones completas antes de empesar la instalación. Instalar y cablear en acuerdo a las reglas nacionales y códigos locales por un electricista certifi cado. El accesorio puede estar agudo, agarre con cuidado deje que el acessorio. Enfriar antes

de mantenimiento.DISTORT JOINT

1 5/8” (42 mm)

3 1/8” min. (79 mm)

3 3/4” max. (95 mm)4”

(102 mm)Top of wiring box

1 5/8” (42 mm)

3 1/8” min. (79 mm)

3 3/4” max. (95 mm)4”

(102 mm)Top of wiring box

Page 2: Installation Instructions Regolo RM1 Recessed€¦ · Regolo RM1 Recessed MUDRN CLN MUN NLITE Lighting Inc. 177 East 51st Avenue Denver, CO 043 Phone (303) 27-646 February 21 Page

Installation InstructionsRegolo RM1 Recessed

MUDRING CEILING MOUNT

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com February 2019

Page 2

RECESSED GRID CEILING INSTALLATION DETAILS

Non-Power FeedPower Feed

Mud Skim Coat

STANDARD LENGTHS STANDARD SHAPES

ORDERING EXAMPLE FOR STANDARD LENGTH

RM1-FF-05L40-1C-U-D-W-4ORDERING EXAMPLE FOR (U) SHAPE

RM1-FF-05L40-1C-U-D-W-4-U/D1-8’/D2-15’

607

mm

2' 3' 4' 5' 6' 7' 8'

914

mm

1219

mm

1524

mm

1828

mm

2134

mm

2438

mm

Tool less continuous joining

Adjustable Bracket design

LinesFor linear individuals and contionuous linear runs specify run lengths to the nearest foot for standard configurations. We can easily achieve lengths to the nearest 1/8” if necessary, custom drawings and lead times may apply.

Note:Although these are standard shapes, take offs and shop drawings may be required depending on field conditions, ceiling type, etc. Consult your local Nulite rep with questions and concernsEquilateral Triangles (EQ)

D1

T Shapes (T) Tri Prong Shapes (TP) U Shapes (U)

D1

D1

D1

D2D2

Squares and Rectangles (SQ) L Shapes (L) X Shapes (X)

D1 D1

D1

D2 D2

Page 3: Installation Instructions Regolo RM1 Recessed€¦ · Regolo RM1 Recessed MUDRN CLN MUN NLITE Lighting Inc. 177 East 51st Avenue Denver, CO 043 Phone (303) 27-646 February 21 Page

Installation InstructionsRegolo RM1 Recessed

MUDRING CEILING MOUNT

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com February 2019

Page 3

RM1 fixture end view RM1 fixture side view

1

24”, 36”, 48”, 60”, 72”, 84”, or 96”

1.70”

2.40”Cutout Width

Distance bwetween blocking

Individual Fixture Cut-Out Length (Add 1/8” to fixture length) Continous Row Cut-Out Length (Add 5/8” to row length)

installing an individual or row starter luminaire

Page 4: Installation Instructions Regolo RM1 Recessed€¦ · Regolo RM1 Recessed MUDRN CLN MUN NLITE Lighting Inc. 177 East 51st Avenue Denver, CO 043 Phone (303) 27-646 February 21 Page

Installation InstructionsRegolo RM1 Recessed

MUDRING CEILING MOUNT

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com February 2019

Page 4

Remove splice box using screwdriver

Secure the flex to the splice box cover. Connect line voltage leads to fixture leads.

Remove knockout on splice box cover and feed line voltage leads the hole

Secure the splice cover using the screws from step 2.

2

4

3

5

installing an individual or row starter luminaire

Page 5: Installation Instructions Regolo RM1 Recessed€¦ · Regolo RM1 Recessed MUDRN CLN MUN NLITE Lighting Inc. 177 East 51st Avenue Denver, CO 043 Phone (303) 27-646 February 21 Page

Installation InstructionsRegolo RM1 Recessed

MUDRING CEILING MOUNT

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com February 2019

Page 5

installing an individual or row starter luminaire

Insert luminaire into ceiling hole.

Push up on the yoke bolts. Make sure yoke legs snap over ceiling to swecure the luminaire.

Dislodge the lens/LED board assembly from the bottom of the luminaire and let it hang by the support chains.

Secure the luminaire to blocking with drywall screws. Screws provided by others.

6

8

7

9

Page 6: Installation Instructions Regolo RM1 Recessed€¦ · Regolo RM1 Recessed MUDRN CLN MUN NLITE Lighting Inc. 177 East 51st Avenue Denver, CO 043 Phone (303) 27-646 February 21 Page

Installation InstructionsRegolo RM1 Recessed

MUDRING CEILING MOUNT

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com February 2019

Page 6

After the“starter” or“ mid” is fully secured with tie-wires, then make power connection and mount the next luminaire, then join them together as shown below and secure with two torsion spring latches that are integrated into the luminaire.

10 11

13

14 15

12

SNAP!

installing a row-mid or row-end (after starter has been installed, step 2 to 9 from page 4 & 5)

Dislodge the lens/LED board assembly from the bottom of the luminaire and let it hang by the support chains.

Insert alignment tabs from the next fixture into the slots on the current fixture.

Connect the strap to the hole in the catch tray. Collapse the alignment strap back to its original position to lock the two fixtures together.

Release the alignment strap from the current fixture and extend the catch tray from the next fixture.

Connect male electrical connector from next fixture to female connector on the current fixture.

Page 7: Installation Instructions Regolo RM1 Recessed€¦ · Regolo RM1 Recessed MUDRN CLN MUN NLITE Lighting Inc. 177 East 51st Avenue Denver, CO 043 Phone (303) 27-646 February 21 Page

Installation InstructionsRegolo RM1 Recessed

MUDRING CEILING MOUNT

NULITE Lighting Inc. 10770 East 51st Avenue Denver, CO 80430 Phone (303) 287-9646 www.nulite-lighting.com February 2019

Page 7

16 17

installing a row-mid or row-end (after starter has been installed, step 2 to 9 from page 4 & 5)

Replace the lens/LED board assembly from the bottom of the luminaire. Repeat for all fixture in the row.

Apply joint compound around the luminaire. Feather the edges, the mud should stop at the lens and end cap.