Code No. 0816748Rev. 3 (06/16)
INSTALLATION INSTRUCTIONS FOR OPTIMA® SYSTEMS SENSOR ACTIVATEDSLOAN® and REGAL® CONCEALED and EXPOSED URINAL FLUSHOMETERS
LIMITED WARRANTYSloan Valve Company warrants its ES-S Sensor Activated Sloan® and Regal® Flushometers to be made of first class materials, free from defects of material or workmanship under normal use and to perform the servicefor which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes) from date of purchase. During this period, SloanValve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under thiswarranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan ValveCompany for purpose of resale.THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLEFOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
2-3/4"(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
2”(51 mm)
TOP OFFIXTURE
C/L OF ELEC. BOX & FIXTURE
2-3/4(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
2”(51 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
Model 195 Model 197
1” I.P.S.SUPPLY
(DN 25 mm)
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
8”(203 mm)
5”(127 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
TOP OFFIXTURE
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
C/L OF ELEC. BOX & FIXTURE
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
8”(203 mm)
5”(127 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
VALVE ROUGH-IN
2-3/4"(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
2”(51 mm)
TOP OFFIXTURE
C/L OF ELEC. BOX & FIXTURE
2-3/4(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
2”(51 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
Model 195 Model 197
1” I.P.S.SUPPLY
(DN 25 mm)
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
8”(203 mm)
5”(127 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
TOP OFFIXTURE
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
C/L OF ELEC. BOX & FIXTURE
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
8”(203 mm)
5”(127 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
2-3/4"(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
2”(51 mm)
TOP OFFIXTURE
C/L OF ELEC. BOX & FIXTURE
2-3/4(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
2”(51 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
Model 195 Model 197
1” I.P.S.SUPPLY
(DN 25 mm)
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
8”(203 mm)
5”(127 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
TOP OFFIXTURE
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
C/L OF ELEC. BOX & FIXTURE
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
8”(203 mm)
5”(127 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
2-3/4"(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
2”(51 mm)
TOP OFFIXTURE
C/L OF ELEC. BOX & FIXTURE
2-3/4(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
2”(51 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
Model 195 Model 197
1” I.P.S.SUPPLY
(DN 25 mm)
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
8”(203 mm)
5”(127 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
TOP OFFIXTURE
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
C/L OF ELEC. BOX & FIXTURE
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
8”(203 mm)
5”(127 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
2-3/4"(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
2”(51 mm)
TOP OFFIXTURE
C/L OF ELEC. BOX & FIXTURE
2-3/4(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
2”(51 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
Model 195 Model 197
1” I.P.S.SUPPLY
(DN 25 mm)
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
8”(203 mm)
5”(127 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
TOP OFFIXTURE
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
C/L OF ELEC. BOX & FIXTURE
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
8”(203 mm)
5”(127 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
MODEL 180 ES-S MODEL 186 ES-S MODEL 190 ES-S
MODEL 192 ES-S MODEL 195 ES-S
Exposed Urinal Flushometers1-1/4" Top Spud• Model 180 ES-S3/4" Top Spud• Model 186 ES-S
Concealed Urinal Flushometers1-1/4" Back Spud• Model 190 ES-S3/4" Back Spud• Model 195 ES-S1-1/4" Top Spud• Model 192 ES-S3/4" Top Spud• Model 197 ES-S
EXPOSEDFLUSHOMETER
2-3/4"(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
2”(51 mm)
TOP OFFIXTURE
C/L OF ELEC. BOX & FIXTURE
2-3/4(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
TOP OFFIXTURE
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
2”(51 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
Model 195 Model 197
1” I.P.S.SUPPLY
(DN 25 mm)
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
13-1/2”(343 mm)
8”(203 mm)
5”(127 mm)
3/4” I.P.S.SUPPLY
(DN 20 mm)
TOP OFFIXTURE
2-1/4” MIN.(57 mm)
2-3/4”(70 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
11-1/2”(292 mm)
C/L OFSUPPLY
C/L OFELEC.BOX
TOP OFFIXTURE
1”(25 mm)
4-3/4”(121 mm)
2-1/4”(63 mm)
C/L OF ELEC. BOX & FIXTURE
2-3/4”(70 mm)+ WALL
THICKNESS
C/L OFSUPPLY
2-3/4”(70 mm)
1-1/2”(38 mm)
4-3/4”(121 mm)
14-1/2”(368 mm)
8”(203 mm)
5”(127 mm)
1” I.P.S.SUPPLY
(DN 25 mm)
MODEL 197 ES-S
SENSOR LOCATION & POSITIONING IS CRITICAL!Failure to properly position the electrical boxes to the plumbing rough-in will result in improper installation and impair product performance. All tradesmen(plumbers, electricians, tile setters, etc.) involved with the installation of this product must coordinate their work to assure proper product installation.
CONCEALEDFLUSHOMETER
Made in the U.S.A.
Sloan Electronics are:
PRIOR TO FLUSHOMETER INSTALLATIONPrior to installing the Sloan OPTIMA equipped Flushometer, install the itemslisted below. Refer to Rough-ins on Page 1 and illustrations on this page.• 2-gang electrical box — 4" x 4" x 2-1/2" (102 mm x 102 mm x 64 mm)
for sensor; see paragraph entitled "Sensor Location"• 2-gang electrical box — 4" x 4" x 2-1/2" (102 mm x 102 mm x 64 mm)
for transformer; see paragraph entitled “Transformer Installation” (mountin a convenient location)
• Electrical wiring to the transformer box (120 VAC, 2 amp service requiredfor each EL-154, 24 VAC, 50 VA transformer used)
• Urinal fixture• Drain line• Water supply lineImportant:• ALL ELECTRICAL WIRING IS TO BE INSTALLED IN ACCORDANCE WITH
NATIONAL/LOCAL CODES AND REGULATIONS.• ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH APPLICABLE
CODES AND REGULATIONS.• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE
VOLUME OF WATER FOR EACH FIXTURE.• A 24 VAC STEP-DOWN TRANSFORMER MUST BE USED.• USE APPROPRIATE PRECAUTIONS WHILE CONNECTING TRANSFORMER
TO 120 VAC POWER SOURCE.• FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
Sloan® and Regal® Flushometers are designed to operate with 15 to 100 psi(104 to 689 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TOTHE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consultfixture manufacturer for minimum pressure requirements.Most Low Consumption water closets (1.6 gallon/6.0 liter) require aminimum flowing pressure of 25 psi (172 kPa).Protect the Chrome or Special finish of this Flushometer — DO NOTUSE TOOTHED TOOLS TO INSTALL OR SERVICE THEVALVE. Also, see "Care and Cleaning" section of this manual.IMPORTANT: EXCEPT FOR CONTROL STOP INLET, DONOT USE PIPE SEALANT OR PLUMBING GREASE ONANY VALVE COMPONENT OR COUPLING!
Transformer InstallationInstall Transformer (EL-154) on a 2-Gang Electrical Box, 4" x 4" x 2-1/2"(102 mm x 102 mm x 64 mm) in a convenient location; refer to theillustration at upper right side of this page.Note: One Sloan EL-154 transformer can operate up to ten OPTIMA equippedFlushometers. Run 18-gauge wire from transformer to Flushometer(s). Wiresupplied by others. DO NOT supply power to transformer until installation ofFlushometer is complete.
Note: A maximum of ten (10) Flushometer units can operate from one (1)Sloan EL-154 Transformer, Class 2, UL Listed, 50 VA (min.) at 24 VAC, platemounted.
Sensor LocationUrinal models employ one (1) electrical box. Refer to rough-in illustrations forlocations.
ELECTRICAL BOX LOCATION IS CRITICAL — Failure toproperly position the electrical boxes to the plumbingrough-in will result in improper installation and impairproduct performance. All tradesmen (plumbers,electricians, tile setters, etc.) involved with theinstallation of this sensor activated flushometer must befamiliar with the requirements of its installation.Improper installation may void the manufacturer'swarranty.Note: A template is packaged with Models 180 ES-S and 186 ES-S valvesto properly position electrical boxes. Refer to rough-in illustrations forinstallation of electrical boxes.Note: Use Appleton #4SD1 Electrical Box and #8470 Plaster Ring orequivalent.Note: Install plaster ring so screw holes are on left andright side of box.Note: Break tiles to allow screw holes in plaster to show.
Tools Required for Installation• Slotted screwdriver• 5/64" hex wrench (supplied)• Wire stripper/crimping tool• Sloan A-50 Super-Wrench™, Sloan A-109 Plier Wrench or smooth jawed
spud wrench
2
With the exception of Control Stop Inlet, DO NOT use pipe sealant or plumbing greaseon any valve component or coupling!
!!! IMPORTANT !!!
Protect the chrome or special finish of Sloan Flushometers — DO NOT USE toothedtools to install or service these valves. Use a Sloan A-50 Super-Wrench™, Sloan A-
109 Plier Wrench or smooth jawed spud wrench to secure all couplings. Also see“Care and Cleaning” section of this manual.
!!! IMPORTANT !!!
This product contains mechanical and/or electrical components that are subject tonormal wear. These components should be checked on a regular basis and replaced
as needed to maintain the valve’s performance.
!!! IMPORTANT !!!
If you have questions about how to install your Sloan Flushometer, consult your localSloan Representative or call Sloan Installation Engineering Department at:
1-888-SLOAN-14 (1-888-756-2614) OR 1-847-233-2016
2-GANG ELECTRICAL BOX -4" x 4" x 2½" (102 mm x 102 mm x 64 mm)
EL-154 TRANSFORMER †
† MOUNT TRANSFORMERWITHIN 50 FEET (15 m) OFFLUSHOMETER
ELECTRICAL BOX INSTALLATION DIAGRAM 4” (102 mm) SQ. BOX DEVICE COVER (PLASTER RING) 3/4” (19 mm)HIGH — APPLETON ELECT. #8470 OR EQUAL (BY CONTRACTOR)
4” (102 mm)SQ. x 2-1/2” (64mm) DEEPOUTLET BOX —APPLETONELECT. #4SD1OR EQUAL (BYCONTRACTOR)
FINISHED TILE WALL
FINISHED PLASTER WALL
COVER PLATENOTE: INSTALLPLASTER RING SO
THAT SCREW HOLESARE ON THE LEFT
AND RIGHT SIDE OFBOX
FINISHED WALL OPENINGEL-168-AYOKE ASSEMBLY
(INSTALL WITHOFFSET PORTION IN
DEVICE COVER)TABS OF YOKE AND
SENSOR TO BE MOUNTEDON TOP OF FINISHED
PLASTER OR TILE WALL
EL-1500SENSOR
NOTE: SENSOR NOTCONNECTED AND
INSTALLED UNTIL STEP 6(VIEW WITH COVER REMOVED)
3
2 Install Cover Tube, Wall Flangeand Control Stop to supply pipe1 Install Optional Sweat Solder
Adapter (only if your supplypipe does not have a malethread)
A Measure from finishedwall to C/L of FixtureSpud. Cut pipe 1¼"(32 mm) shorter thanthis measurement.Chamfer O.D. and I.D.of water supply pipe.
WATER SUPPLY PIPE
FINISHED WALL
1-1/4” (32 mm)
C/L OFFIXTURE
SPUD
SWEATSOLDERADAPTER
B Slide Threaded Adapterfully onto pipe.
C Sweat solder theAdapter to pipe.
With the exception of Control Stop Inlet, DO NOT use pipe sealant or plumbinggrease on any valve component or coupling!
!!! IMPORTANT !!!
WALLFLANGE
BAK-CHEK®
CONTROL STOP
IRON PIPE NIPPLE OR COPPER PIPEWITH SWEAT SOLDER ADAPTER
SET SCREW
COVERING TUBE
Thread Control Stop onto pipe.Tighten with a wrench.
WATERSUPPLY PIPE
SWEAT SOLDERADAPTER
COVER TUBE
WALLFLANGE
SET SCREW
A Measure from finished wall to first thread of Adapter orthreaded supply pipe(dimension “X”). Cut CoverTube to this length.
B Slide Cover Tube over pipe.Slide Wall Flange over CoverTube until against wall.
C
3 Install Vacuum Breaker FlushConnection
A Assemble Pipe, Elbows,Couplings, Nylon SlipGasket, Rubber Gaskets andFlanges as illustrated.
B Insert Tube into Fixture Spud.
C Hand tighten all Couplings.
MODEL186ES-S
MODEL180 ES-S
MODEL195 ES-S
VACUUMBREAKERTUBESPUD
COUPLINGNYLON SLIPGASKETRUBBERGASKET
SPUDFLANGE
4 Install Flushometer
CAlign Flushometer Body and securely tighten first the TailpieceCoupling (1), then the Vacuum Breaker and Pipe Couplings (2), andfinally the Spud Coupling (3). Use a wrench to tighten thesecouplings in the order shown.
B Align Flushometer directly above the Vacuum Breaker FlushConnection by sliding the Flushometer Body IN or OUT as needed.Tighten Vacuum Breaker Coupling by hand.
A Lubricate tailpiece O-ring with water. Insert Adjustable Tailpiece intoControl Stop. Tighten Tailpiece Coupling by hand.
Max. adjustment of Sloan Adjustable Tailpiece is ½" (13 mm) IN or OUTfrom the standard 4¾" (121 mm) (c/l of Valve to c/l of Control Stop).
If roughing-in measurement exceeds 5¼” (133 mm), consult factory forlonger tailpiece.
NOTE
0816748 0816749
G-44 FRICTION RING
C/L FIXTURE
CONTROL STOPO-RING
TAILPIECE COUPLING
VACUUM BREAKER FLUSHCONNECTION
VACUUM BREAKERCOUPLING
FLUSHOMETER BODY
SPUD COUPLING
ADJUSTABLE TAILPIECE
1
2
3 C/L SUPPLY
MODEL190 ES-S
MODEL197 ES-S
MODEL192 ES-S
1-1/4” (32 mm) MIN.
IMPORTANT: WHEN CUTTINGSCORED PIPE TO LENGTH LEAVEA MINIMUM OF 1-1/4” (32 mm)OF SCORING TO ENSURE PROPERENGAGEMENT
INSTALL WITHFLANGE AGAINSTELBOW
X
4-3/4"(121 mm)+/- 1/2”(13 mm)
EXPOSEDINSTALLATION
SHOWN
VACUUMBREAKERREPAIR KIT
CONTROL STOPCAP
Tighten Wall Flange Set Screw with hexwrench supplied. DO NOT install VandalResistant Stop Cap at this time.
D
For high efficiency urinal flushometers (0.5, 0.25 and 0.125 gpf), it isnecessary to first insert the flow control component into the tailpieceassembly. See the H1015A flow control kit and separate instructions fordetails on how to install.
NOTE
4
5 Connect Solenoid Operator
A To ease installation, remove the Solenoid Operator from theFlushometer; however, prior to removal, read and adhere to thefollowing precautions.• When removing the Coil from the Solenoid Plunger Guide, do so
only with the power OFF. Failure to turn power off can result indamage to the Sensor, Solenoid Coil and Transformer.
• When removing the Solenoid Operator from the Valve, take carenot to damage the O-ring seal on the Operator Assembly.
C Exposed models only— Slide Flange Assembly (EL-431-A)and Cover Plate (EL-151) over Tail, respectively.
COVER PLATE(EL-151)
FLANGE ASSEMBLY(EL-431-A)
TAIL(F-15)
HANDLECOUPLING (A-6)
CARTRIDGE ASSEMBLY(EL-128-A)
SOLENOID SHAFT ASSEMBLYW/SOLENOID ADAPTER (EL-163-A)
COIL (EL-165-2)
SOLENOIDHOUSING (EL-162-2)
NUT (EL-101)
SOLENOIDOPERATOR(EL-124-2)SCREW
(EL-152) (4 REQ’D)
EXPOSED FLUSHOMETER CONCEALED FLUSHOMETER
B Exposed models only— Slide Coil wires through Tail (F-15)and screw Tail into Solenoid Housing (EL-162-2).
Important: Do not remove coil from solenoid plunger guide unless power has been disconnected. Failure to do so may damage sensor, coil and transformer.
FACE PLATE(EL-102-2)
PLATE (EL-164)
6 Electrical Hook-Up
A Be certain power is OFF to prevent damage to electricalcomponents. Connect Sensor to Transformer and Solenoid coilEXACTLY as shown.
B Connect 24 volt source lead to terminal labeled “24 VAC IN” ofSensor.
UNIT #2THRU #10(IF USED)
UNIT #1
WIRINGDIAGRAM
120 VAC
24 VACEL-1500 SENSOR
EL-1500 SENSOR
24 VAC COILCOIL WIRE
24 VAC COILCOIL WIRE
Connect solenoid lead to terminal labeled “TO VALVE” of Sensor.C
Connect remaining solenoid lead to remaining 24 volt source lead.D
YOKE(EL-168-A)
SENSOR (EL-1500)
HANDLECOUPLING (A-6)
CARTRIDGE ASSEMBLY(EL-128-A)
SOLENOID SHAFT ASSEMBLY W/SOLENOID ADAPTER (EL-163-A)
COIL (EL-165-2)
SOLENOIDHOUSING(EL-541-A)
SOLENOIDOPERATOR(EL-138-2)
NUT (EL-166)
FACE PLATE(EL-102-2)
BASE PLATE (EL-542)
Wiring Diagram for One Flush Valve
Wiring Diagram for Multiple Flush Valves
SENSOR
VALVE
SOLENOID
SENSOR
VALVESOLENOID
SENSOR
VALVESOLENOID SOLENOID
VALVE
TRANSFORMER
TRANSFORMER
SENSOR
5
7 Install Sensor and Yoke
A Install OPTIMA Sensor (EL-1500) into the 2-gang Electrical Boxusing two (2) long screws provided. Ensure that Sensor Lens facesoutward and horizontally from finished wall. Mount Yoke(EL-168-A) using two (2) long screws provided.
8 Install Sensor Cover Plate andSecure Solenoid Housing andCoil Assembly
B Models 180 ES-S and 186 ES-S— Carefully installSolenoid Operator to Flushometer while aligning Tail Assembly toCover Plate. Wet O-Ring seal of Solenoid Operator with water tolubricate. Secure Solenoid Operator to Flushometer by tighteningSolenoid Coupling. Slide Solenoid Flange Assembly (EL-431-A)against Sensor Cover Plate (EL-151) and tighten Setscrew to Tail (F-15).Note: Hex key wrench services Tamper-Proof Screws andSetscrew. Tighten solenoid Nut (EL-101).
A Install Sensor Cover Plate(EL-151, Exposed; EL-161,Concealed) and secure withTamper-Proof Screws(EL-152), provided.
YOKE(EL-168-A)
SENSOR(EL-1500)
10Power and Start-up Mode
A Turn Power ON. The self adaptive sensor automatically adapts tothe surrounding environment when 24 volt supply is activated. Nomanual adjustments are required.
Note: It is recommended that all electronic connections be tested with thewater supply OFF.
B Start-up mode will take approximately five (5) minutes to completeits cycle and is important that no non-permanent target is presentat this time. A continuous red light visible in sensor windowindicates sensor is in the start-up mode. If the red light is flashing,this indicates that the sensor is picking up a target. Unless thistarget is a permanent fixture in the sensor’s environment (i.e., awall or stall door), it must be removed from the view of the sensor.If this target is permanent, the sensor will adapt itself around thistarget. In this case, the start-up mode may take up to ten (10)minutes. When the start-up cycle is completed, no light is visible insensor window.
Note: If 24 volt power supply is interrupted at any time for more thanfifteen (15) seconds, the start-up mode automatically repeats itself whenpower is restored.
C If indicator light flashes three (3) times slowly, three (3) timesrapidly and again three (3) times slowly and continually repeats this signal, this indicates incorrect wiring or a short in the 24 volt supply.
9 Flush Out Supply Line
C Open Control Stop. Turn on water supply to flush line of any debrisor sediment.
B Remove FlushometerCover and lift outInside Parts Assembly.Install FlushometerCover wrench tight.
D Shut off Control Stop, remove Cover and reinstall Inside PartsAssembly. Install Flushometer Cover wrench tight. Do Not openControl Stop until Step 12.
A Make sure ControlStop is CLOSED.
6
Operation
1. A continuous, invisible light beam is emittedfrom the OPTIMA Sensor.
2. When a user enters the beam’s effectiverange, 15 to 30 inches (381 mm to 762 mm),the beam is reflected into the OPTIMA’sscanning window and transformed into a lowvoltage electrical signal that activates a ten-second time delay circuit. The time delaycircuit eliminates false operation frompassers-by in the rest room. Once the timedelay is completed, the output circuit isalerted and continues in a “hold” mode for aslong as the user remains within the effectiverange of the sensor.
3. When the user steps away from the OPTIMASensor, the loss of reflected light initiates anelectrical “one-time” signal that energizes theSolenoid Operator, and activates theFlushometer to flush the fixture. The circuitthen automatically resets and is ready for thenext user.
Care and Cleaning
DO NOT use abrasive or chemical cleaners (including chlorine bleach) toclean Flushometers as they may dull the luster and attack the chrome or specialdecorative finishes. Use ONLY soap and water, then wipe dry with clean cloth ortowel.While cleaning the bathroom tile, the Flushometer should be protected from anysplattering of cleaner. Acids and cleaning fluids can discolor or remove chromeplating.
12Turn Water on and AdjustControl Stop
A Adjust Control Stop to meet the flow rate required for propercleansing of the fixture. Open Control Stop COUNTERCLOCKWISE1/2 turn from the closed position.
B Activate Flushometer by placing hand in front of OPTIMA SensorLens for ten (10) seconds and then moving it away.
C Adjust Control Stop after each flush until the rate of flow deliveredproperly cleanses the fixture.
The Sloan® and Regal® Flushometer is engineered for quiet operation.Excessive water flow creates noise, while too little water flow may not
satisfy the needs of the fixture. Proper adjustment is made whenplumbing fixture is cleansed after each flush without splashing water out
from the lip AND a quiet flushing cycle is achieved.
Never open Control Stop to where the flow from the valve exceeds theflow capability of the fixture. In the event of a valve failure, the fixture
must be able to accommodate a continuous flow from the valve.
!!! IMPORTANT !!!
Exposed Model Shown
11Detection/ActivationA When an object is detected, a slowly flashing red light will appear
in the sensor window. After approximately eight (8) to ten (10)seconds, the light will flash rapidly indicating sensor is armed andready to activate solenoid when the object leaves the detectionarea. The solenoid will be activated within two (2) to four (4)seconds after non-detection.
EXPOSED FLUSHOMETER
CONCEALED FLUSHOMETER
D Install Vandal Resistant Control Stop Cap onto Control Stop.
7
1. PROBLEM: Valve does not function (red light does not flash when usersteps in front of sensor).
CAUSE: No power is being supplied to sensor.SOLUTION: Ensure that the main power is turned “ON.” Check
Transformer, leads and connections. Repair or replace asnecessary.
CAUSE: EL-1500 Sensor is not operating.SOLUTION: Replace EL-1500 Sensor.
2. PROBLEM: Valve does not function (red light flashes when user steps infront of Sensor).
INDICATOR: Red light stops flashing when user steps away and valvemakes a “clicking” sound but does not flush.
CAUSE: No water is being supplied to the valve.SOLUTION: Make certain that water supply is turned “ON” and the
Control Stop is open.
CAUSE: EL-128-A Cartridge is fouled or jammed.SOLUTION: Turn electronic power to valve “OFF” (failure to do so could
result in damage to the solenoid coil). Remove the solenoidoperator from the valve and remove theEL-128-A cartridge. Clean and/or repair as necessary.
INDICATOR: The red light stops flashing when user steps away but thevalve does NOT make a “clicking” sound and does NOT flush.
CAUSE: EL-163-A Solenoid Shaft assembly is fouled or jammed. SOLUTION: Turn electronic power to valve “OFF” (failure to do so could
result in damage to the Solenoid Coil). RemoveEL-101 or EL-166 nut from the Solenoid Operator. Removethe coil from the solenoid operator. Use a spanner wrench orpliers to remove the EL-163-A Solenoid Shaft assembly fromvalve. Clean and/or replace as necessary. Be sure to replacePlunger Spring when reassembling Solenoid Shaft Assembly.
INDICATOR: The red light flashes three (3) short flashes, three (3) longflashes then three (3) short flashes (“S-O-S”) and continuesto repeat this cycle even when user steps out of the sensor’sdetection range.
CAUSE: EL-1500 Sensor wiring connections are incorrect. SOLUTION: Rewire Sensor to valve. One solenoid lead connects to the
“TO VALVE” connection on Sensor. One transformer leadconnects to the “24 VAC IN” connection on Sensor. Secondsolenoid lead and second transformer lead connect together.
CAUSE: Wiring to Sensor is ground shorted.SOLUTION: Find short in wiring circuit and correct.
CAUSE: EL-165-2 Solenoid Coil is burnt out or Coil is not connectedto Solenoid Plunger shaft.
SOLUTION: Reinstall or replace Coil as necessary.
3. PROBLEM: Volume of water is insufficient to adequately siphon fixture.
CAUSE: Control Stop is not open wide enough.SOLUTION: Adjust Control Stop for desired water delivery.
CAUSE: Low Consumption unit is installed on Water Saver orConventional fixture.
SOLUTION: Replace Diaphragm component parts of valve with kit thatcorresponds to appropriate flush volume of fixture.
CAUSE: Inadequate water volume or pressure available from supply.SOLUTION: Increase pressure or supply (flow rate) to the valve. Consult
factory for assistance.
4. PROBLEM: Length of flush is too long (long flushing) or valve fails to shutoff.
CAUSE: Water Saver Valve is installed on Low Consumption fixture.SOLUTION: Replace Diaphragm component parts of valve with kit that
corresponds to appropriate flush volume of fixture.
CAUSE: Relief valve in Diaphragm is not seated properly or bypasshole in Diaphragm is clogged.
SOLUTION: Disassemble inside Diaphragm component parts and washparts thoroughly. Replace worn parts if necessary.
5. PROBLEM: Water splashes from fixture.
CAUSE: Supply flow rate is more than necessary.SOLUTION: Adjust Control Stop to meet flow rate required for proper
cleansing of the fixture.
CAUSE: Closet valve is installed on urinal fixture.SOLUTION: Replace closet Diaphragm component parts with proper urinal
kit (Inside Diaphragm Assembly or Inside Parts Kit).
If further assistance is required, please contact the Sloan Valve CompanyInstallation Engineering Department at:
1-888-SLOAN-14 (1-888-756-2614)
Never open Control Stop to where the flow from the valve exceeds the flowcapability of the fixture. In the event of a valve failure, the fixture must be
able to accommodate a continuous flow from the valve.
!!! IMPORTANT — Control Stop Setting !!!
TROUBLESHOOTING GUIDE
NOTE: Upon detection of the user, the red indicator light flashes slowly for a period of eight seconds. When the user leaves the detection range, theindicator light flashes rapidly and the Sensor initiates the flush sequence. Then the indicator light stops flashing and the valve flushes.
SLOAN VALVE COMPANY • 10500 Seymour Avenue • Franklin Park, IL 60131Phone: +1.800.982.5839 or +1.847.671.4300 • Fax: +1.800.447.8329 or +1.847.671.4380
www.sloan.com06-16Copyright © 2016 SLOAN VALVE COMPANY
23
PARTS LIST
Item Part DescriptionNo. No.
1 ‡ Solenoid Operated Valve Assembly2 H-700-A ‡ 1” (25 mm) Bak-Chek® Control Stop
H-700-A ‡ 3/4” (20 mm) Bak-Chek® Control Stop3A V-600-AA 1-1/4" (32 mm) x 9" (229 mm) Vacuum Breaker Assembly
CP (Model 180 ES-S)3B V-600-AA 3/4" (20 mm) x 9" (229 mm) Vacuum Breaker Assembly CP
(Model 186 ES-S)3C V-500-AA 1-1/2" (38 mm) x 11-1/2" (292 mm) Vacuum Breaker
Assembly RB (Model 190 ES-S)3D V-500-AA 3/4" (19 mm) x 10-1/2" (267 mm) Vacuum Breaker
Assembly RB (Models 195 ES-S and 197 ES-S)3E V-500-AA 1-1/2" (38 mm) x 7-1/2" (191 mm) Vacuum Breaker
Assembly RB (Model 192 ES-S)4A F-5-A 1-1/4" (32 mm) Spud Coupling Assembly
(Model 180 ES-S)4B F-5-A 3/4" (19 mm) Spud Coupling Assembly (Model 186 ES-S)5 F-15-A ELL with 3/4" (19 mm) Tail
(Models 195 ES-S and 197 ES-S)6 F-2-AW 3/4" (19 mm) Slip Joint Coupling
(Models 195 ES-S and 197 ES-S)7 F-21 Double Slip Elbow (Models 190 ES-S and 192 ES-S)8 F-2A 1-1/2" (38 mm) Slip Joint Coupling (Model 190 ES-S)9 F-2A Coupling with S-21 Gasket10 F-110 1-1/4" (32 mm) O.D. Outlet11 F-2-A-U 1-1/4" (32 mm) Slip Joint Coupling12 F-2-AA 1-1/2" (38 mm) Slip Joint Coupling (Set of Two)
(Model 192 ES-S)13 F-102 1-1/2" Outlet Tube CP14 F-7 Flange15 F-25-A 1-1/4" Elbow Assembly16 F-15-A ELL with 3/4" Tail CP (Model 197 ES-S)
Item Part DescriptionNo. No.
17 F-5-A 1-1/4" Spud Coupling Assembly CP18 F-5-A 3/4" Spud Coupling Assembly CP19 F-15 Tail Assembly20 EL-431-A Flange Assembly21A EL-151 Cover Plate (Models 180 ES-S and 186 ES-S)21B EL-161 Cover Plate (Models 190 ES-S, 192 ES-S, 195 ES-S
and 197 ES-S) 22 EL-152 Screw (4 Required)23 EL-168-A Yoke Assembly24 EL-1500 Urinal Sensor
‡ Part number varies with valve model variation; consultfactory.
INSTALLATION TEMPLATE For Models 180/186 ES-S: Code # 0816156
The information contained in this document is subject tochange without notice.
180 ES-S
8
7
3A
186 ES-S 190 ES-S 195 ES-S 192 ES-S 197 ES-S
3B 3C 3D 3E 3D
4A 4B11
10
9
66
7
12
12 13 14
15
17
6 16
18
24
21A
20
19
21B
22 1
2
55 14
Sloan and Regal Detailed Parts Breakdown
For a detailed parts breakdown of Regal Optima ES-S Flushometers, seeMaintenance Guide 0816510.
For a detailed parts breakdown of Sloan Optima ES-S Flushometers, seeMaintenance Guide 0816725.