Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each...

16
Installation Instructions 27" & 30" Electric Built-in Wall Ovens Questions? Calt 1.800.GE.CARES(1.800.432.2737) or visit www.GEAppiiances.com In Canada, calt 1.800.561.3344 or visit www.GEAppliances.ca BEFORE YOU BEGIN Reed these instructions completelg end cerefullg. " IM PORTANT -- Save these instructions for local inspector's use. " IMPORTANT -- Observe all governing codes and ordinances. , Note to Installer- Be sure to leave these instructions with Consumer. , Note to Consumer- Keep these instructions for future reference. , Skill level- Installation of this appliance requires a qualified installer or electrician. . Proper installation is the responsibility of the installer. , Product failure due to improper installation is not covered under Warranty. , Product is for indoor use onlg. ATTENTION INSTALLER: All electric wall ovens must be hard-wired (direct-wired)into an approved junction box. A plug and receptacle is NOT permitted on these products. FOR YOUR SAFETY: WAR N IN G: Before beginning the installation, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentallg. When the service disconnecting means cannot be locked, securelg fasten a prominent warning device, such as a tag, to the service panel. Be sure the oven is securelg installed in a cabinet that is firmlg attached to the house structure. Weight on the oven door could cause the oven to tip and result in injurg. Never allow angone to climb, sit, stand or hang on the oven door. Make sure the wall coverings, counters and cabinets around the oven can withstand the heat (up to 200°F [93.3°C])generated bg the oven. MATERIALS YOU MAY NEED JunctionBox Wire Nuts Strain Relief Clamp for 1/2" Conduit TOOLS YOU MAY NEED 1/8" Drill Bit and Electric or Hand Drill Phillips Screwdriver Wire Strippers DESIGN INFORMATION SINGLEOVEN INSTALLATIONS The single oven mag be installed in a cabinet alone or above a warming drawer. The single oven meg also be installed below a countertop or below specified cooktops. See the label on top of the oven for approved models. DOUBLEOVEN INSTALLATIONS A double oven mag be installed in a cabinet alone or above a warming drawer. Seethe label on top of the oven for approved models. IMPORTANT: Alwagsreferto individualinstallationinstructionspackedwith eachproductforspecific requirements. I_] PREPARE THE OPENING NOTE: If the cabinet does not have a solid bottom, two braces or runners must be installed to support the weight of the oven. For single ovens, the runners and braces must support 200 Ibs 191kg). For double ovens, the runners and braces must support 375 Ibs. 1170 kg). NOTE: If marks, blemishes or the cutout opening are visible above the installed oven, it mag be necessarg to add wood shims under the runners and front trim until the marks or opening are covered. NOTE: If the cabinet does not have a front frame and the sides are less than sA"11.9cm) thick, shim both sides equallg to establish the cutout width. 2" x 4"(5 cm x 10 cm) or Equivalent Runners Level with Bottom of Cutout and Flush with Sides of Cutout Suitable Bracing to Support. m Ill REMOVE PACKAGING MATERIALS Failure to remove packaging materials could result in damage to the appliance. Remove all packing parts from oven, racks and heating elements. Remove protective film and labels on the outer door and control panel. Also, remove plastic on trims and panel, all tape around the oven and ang shipping screws securing the oven to the base pad. Open oven door and remove literature pack and oven racks. Remove the bottom trim from the top of the oven. It will be installed at the end of the installation process. The trim is wrapped separatelg and taped to the top of the unit. Remove pedestal rails from separate box and set aside (30" Double Wall Ovens Onlg).

Transcript of Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each...

Page 1: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

Installation Instructions

27" & 30" Electric Built-in Wall OvensQuestions? Calt 1.800.GE.CARES(1.800.432.2737) or visit www.GEAppiiances.com

In Canada, calt 1.800.561.3344 or visit www.GEAppliances.ca

BEFORE YOU BEGINReed these instructions completelg endcerefullg.

" IM PORTANT -- Save these instructionsfor local inspector's use.

" IMPORTANT -- Observe allgoverningcodes and ordinances.

, Note to Installer- Be sure to leave theseinstructions with Consumer.

, Note to Consumer- Keep these instructionsfor future reference.

, Skill level- Installation of this appliancerequires a qualified installer or electrician.

. Proper installation is the responsibilityof the installer.

, Product failure due to improper installationisnot covered under Warranty.

, Product is for indoor use onlg.

ATTENTION INSTALLER: All electric wall ovens must be hard-wired (direct-wired)into anapproved junction box. A plug and receptacle is NOT permitted on these products.

FOR YOUR SAFETY:

WAR N ING: Before beginning the installation, switch power off at the service panel andlock the service disconnecting means to prevent power from being switched on accidentallg. When theservice disconnecting means cannot be locked, securelg fasten a prominent warning device, such as a tag,to the service panel.

Be sure the oven is securelg installed in a cabinet that is firmlg attached to the house structure.Weight on the oven door could cause the oven to tip and result in injurg. Never allow angone to climb, sit,stand or hang on the oven door.

Make sure the wall coverings, counters and cabinets around the oven can withstand the heat(up to 200°F [93.3°C])generated bg the oven.

MATERIALS YOU MAY NEED

JunctionBox

Wire Nuts

Strain Relief Clamp for 1/2" Conduit

TOOLS YOU MAY NEED

1/8" Drill Bit and Electric or Hand Drill

PhillipsScrewdriver

Wire Strippers

DESIGN INFORMATION

SINGLEOVEN INSTALLATIONS

The single oven mag be installed in a cabinet alone or above a warming drawer. Thesingle oven meg alsobe installed below a countertop or below specified cooktops. See the label on top of the oven for approvedmodels.

DOUBLEOVEN INSTALLATIONS

A double oven mag be installed in a cabinet alone or above a warming drawer. Seethe label on top of theoven for approved models.

IMPORTANT:Alwagsreferto individualinstallationinstructionspackedwith eachproductfor specificrequirements.

I_] PREPARE THE OPENING

NOTE: If the cabinet does not have a solid bottom, twobraces or runners must be installed to support the weightof the oven. For single ovens, the runners and bracesmust support 200 Ibs 191kg). For double ovens, therunners and braces must support 375 Ibs. 1170 kg).

NOTE: If marks, blemishes or the cutout opening arevisible above the installed oven, it mag be necessarg toadd wood shims under the runners and front trim untilthe marks or opening are covered.

NOTE: If the cabinet does not have a front frame andthe sides are less than sA"11.9cm) thick, shim both sidesequallg to establish the cutout width.

2" x 4"(5 cm x 10 cm)or Equivalent Runners Level

with Bottom of Cutoutand Flush with Sides of Cutout

SuitableBracingto Support.

mIll REMOVE PACKAGING MATERIALSFailure to remove packaging materials could result in damage to the appliance. Remove all packingparts from oven, racks and heating elements. Remove protective film and labels on the outer doorand control panel. Also, remove plastic on trims and panel, all tape around the oven and ang shippingscrews securing the oven to the base pad. Open oven door and remove literature pack and ovenracks. Remove the bottom trim from the top of the oven. It will be installed at the end of the installationprocess. The trim is wrapped separatelg and taped to the top of the unit. Remove pedestal rails fromseparate box and set aside (30" Double Wall Ovens Onlg).

Page 2: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

r_==_ CUTOUT FOR SINGLE OVENS IN WALL CABINETNOTE: If the cabinet does not have a front frame and the sides are less than sA" (1.9 cm) thick, shim

both sides equally to establish the cutout width.

These ovensare notapproved forstackableinstallations.

OpeningBetween InsideWails Must beat Least 28-1/2"(724 cm) Wide

H

Sideby-SideInstallationsInstalltwo ovens in separatecutoutsCenter Line Center Line

] so.s"177scrnl ]I 30" models I

] 2T' (68.58crn) ]I 27" modes !I !

--ICutout- Cutout -observeall observealldimensionsand dimensionsandrequirements requirements

"---_1 I_== 2"Is1cm/r_in

JunctionBoxLocation(junctionbox may

Jbe locatedin adjacentcabinetl

: --T22" (559 __-=_lmcm} Hin. to

_ Bottom ofJ Junction

J BOXJ

..... ~%:;, ....-" " Cutou/Depth

(59.7cm} Nlin.

Note: Allow1/4" (0.64 cm)clearancesfrom side

edges of ovendoor.

_____B___-_

tF

G

............................... L ......

t

C

m4_

RecommendedCutout Locationfrom Floor32 1/2" (826 cm)

A ---d

Dimension Dimension Description 27" Single Oven 30" Single Oven

A Cabinet Width 27" (68.6 cm) 30" (76.2 cm)

B Cutout Width 25" (63.5 cm) min. 28½" (72.4 cm) min.25½" (64.1 cm) max. 28sA " (72.7 cm) max.

C Cutout Height 27%" (70.2 cm) min. 27½" (69.2 cm) min.28½" (71.4 cm) max. 27s4d ' (69.4 cm) max.

D Overlap of Oven Over 1" (2.5 cm) _¼_d'(1.75 cm)Side Edges of Cutout

E Clearance to 23" 150.8 cm) min. 23" 153.3 cm) min.

Adjacent Corners,Drawers, Walls, etc.,

When Door Is Open

F Overlap of Oven 1" 12.5 cm) min. 1" 12.5 cm) min.Top of Cutout (11/4'' 13.2 cm) for PT9050)

G Overlap of Oven 1" (2.5 cm) min. 1½" (3.2 cm)Bottom of Cutout

H Junction Box Location 8¾" (22.2 cm) max. 9½" (24.1 cm) max.

right side only right side only

CUTOUT FOR SINGLE OVENS - UNDER COUNTERNOTE: These ovens are only approved to be installed under the specific models as labeled on the unit.

Gas or Electric Cooktops May Be Installed Over This Oven.

See Cooktop Installation instructions for Cutout Size, 240V/208VSee Label on Top of Oven for Approved Models. Junction Box

Location (junctionbox may be

in adjacent cabinet)

25" (63.5 cm)

Gas and Electrical Connections

for Gas Cooktop Must be Locatedin an Adjacent AccessibleLocation to the Right

MUST SUPPORT 200 Ibs. (60 kg) FOR SINGLE OVENSMUST SUPPORT 375 Ibs. (170 kg) FOR DOUBLE OVENS

Side-by-Side InstallationsInstall two ovens in separate cutouts.

center Line CenterLineI 30.5" (775 cm) 30" models

36" (91.4 cm)CountertopHeight

Cutout - observeall dimensions andrequirements.

__q

JL

Cutout = observe

all dimensions and

requirements.

_=2" (5.l cm) Nlin.

NOTE:One cooktop may be centered over either oven inthe side-by-side installation.

Dimension Dimension Description 27" Single Oven 30" Single Oven

A Cabinet Width 25" (63.5 cm) min. 28½" (72.4 cm) min.

25¼" (64.1 cm) max. 28%" (72.7 cm) max.

B Cutout Height 27%" (70.2 cm) min. 27½" (69.2 cm) min.28½" (71.4 cm) max. 27%d' (69.4 cm) max.

C Unit Overlap Top 1" (2.5 cm) 1" (2.5 cm)(1VJ' (5.2 cm) for PT9050)

D Unit Overlap Bottom 1" (2.5 cm) l_/J ' (5.2 cm)

E Unit Overlap Side Edges 1" (2.5 cm) _¼_d'(1.75 cm)

F Junction Box Location 8sA" (22.2 cm) max. 9½" (24.1 cm) max.

right side only right side only

Continue to Section 4.

Page 3: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

CUTOUT FOR DOUBLE OVENS (2THERMAL OVENS)

NOTE: If the cabinet does not have a front frame and the sides are less than sA"(1.9 cm)

both sides equall_h.i

JunctionBO×

Location(junction

/ boxmay/be located

in adjacentcabinet)

lJ

O _

tF

G

t

hick, shim

i

r

%ri

Dim. Description 27" Double Oven 30" Double Oven with 30" Double OvenPedestal without Pedestal

A Cabinet Width 27" (68.6 am) 30" (76.2 am) 30" (76.2 am)

B Cutout Width 25" (63.5 cm) min. 28½" (72.4 cm) min. 28½" (72.4 cm) min.25¼" (64.1cm) max. 28%" (72.7 cm) max. 28%" (72.7 cm) max.

C Cutout Height 4%_d' (126.2cm) min. 5113/S' (131.6 cm) min. 50 ¼" (127.64cm)50½" (127.5 am) max. 51_/_d' (151.9 am) max.

D Overlap of Oven 1" (2.5am) _½d' (1.75 am) _4d' (1.75 am)Over Side Edges

of Cutout

E Clearance to 23" (50.8 cm) min. 23" (53.3 cm) min. 23" (53.3 cm) min.Adjacent Corners,

Drawers, Walls, etc.,When Door/sOpen _ ,

F Overlap of Oven 1" (2.5 am) rain. 1" (2.5 cm) min. 1" (2.5 cm) min.Top of Cutout (1¼"(5.2cm) for PT9550) (1¼"(5.2cm) for PT9550)

G Overlap of Oven 1" (2.5 cm) min. 11/4"(5.2 cm) 11/4"(5.2 cm)Bottom of Cutout

H Junction Box 8sA" (22.2 cm) max. 9½" (24.1 cm) max. 9½" (24.1 cm) max.

Locat!on _ rights!de only _ rights!de only . rights!de only

J Height to Bottom 44" (111.8cm) 47" (i19.4cm) 47" (i19.4cm)of Junction Box

K Recommended 15¼" (55.7 am) 12" (50.5 am) 12" (50.5 am)Cutout Location

from Floor

Continue to Section 3.

J31-i0856-iJo -isGE

CUTOUT FOR INSTALLATION OVER A WARMING DRAWERNOTE: Installtheoven onlywithspecificmodels listedon the labellocatedon topofthe oven.

NOTE: Additionalclearancesbetween cutoutsmay be required.Checktobe suretheoven supportsabove theWorming Drawer locationdo notobstructtherequiredinteriordepthand height.

When installinga Worming Drawer belowa singleordoubleoven,a separate120V,60 HZ,properlygrounded receptaclemustbe installed.Referto installationinstructionspocked withtheWorming Drawer forspecificinstallationrequirements.

Anti-Tip Block AgainstRear Wall Per WarmingDrawer Requirement

2" (5.1 cm)Min.

Per WarmingDrawerRequirement

Continue to Section 3 for DWO with Pedestal. Otherwise, continue to Section 4.

Page 4: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

_-I PEDESTAL RAIL INSTALLATION (DOUBLE OVENS ONLY)A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom

flush with side of cabinet opening. Locate each rail so that front of rail is behind front cabinetopening.

B. Drill pilot holes and attach rails to runner or bottom of cabinet with provided hardware.

Page 5: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

[_ DOOR REMOVAL {RECOMMENDED)

NOTE: Door removal is not a requirement for installation of the product but is an added convenience.

To remove the door:

A. Open the oven door as far as it will go.

B. Push both hinge locks down toward the door frameto the unlocked position. This may require a flat-blade screwdriver. DO NOT LIFTTHE DOOR BYTHEHANDLE!

C. Place hands on both sides of the door and close theoven door to the removal position (approximately1"-2" [2.5 cm-5.1 cm] from the closed position).

D. Lift the door up and out until the hinge arms clearthe slots.NOTE: The oven door is very heavy. Be sureyou have a firm grip before lifting the oven door offthe hinges. Use caution once the door is removed. Donot lay the door on its handle.This could cause dents or scratches.

Hinge_1_ Unlocked

Position

Hinge Slot ,

Hinge Arm

Hinge ClearsSlot

r_ ELECTRICAL REQUIREMENTS

A WARNING: This appliance rnust be properly grounded

A WAR N I N G: To prevent fire or shock, do not use an extension cord with this appliance.

A WA R N I N G: To prevent shock, remove house fuse or open circuit breaker beforebeginning installation.

A WAR N I N G: ,mproperconnectionofa,uminumhousewiring to copper leads can result

in an electrical hazard or fire. Useonly connectors designed for joining copper to aluminum and follow themanufacturer's recommended procedure closely.

We recommend you have the electrical wiring and hookup of your appliance connected by a qualifiedelectrician. After installation, have the electrician show you how to disconnect power from the appliance.

You must use a single-phase, 120/208 VACor 120/240 VAC,60 Hertz electrical system. If you connect toaluminum wiring, properly installed connectors approved for use with aluminum wiring must be used.

Effective Januarg 1, 1996, the National Electrical Code requires that new construction (not existing) utilizea four-conductor connection to an electric oven. When installing an electric oven in new construction,a mobile home, recreational vehicle or an area where local codes prohibit grounding through theneutral conductor, refer to the section on four-conductor branch circuit connections.

Check with your local utilities for electrical codes which apply in your area. Failure to wire your ovenaccording to governing codes could result in a hazardous condition. If there are no local codes, youroven must be wired and fused to meet the National Electrical Code, NFPA No. 70 i latest edition,available from the National Fire Protection Association.

[_] ELECTRICAL REQUIREMENTS {CONT.)

Thisappliance must be supplied with the proper voltage and frequency and connected to an individual,properly grounded branch circuit, protected by a circuit breaker or fuse. See the rating plate located on theoven frame to determine the rating of the product•

Rating PlataLocation ....................................;

_================_ _

Rating plate is located on the oven side trim.

Use the chart below to determine the minimum recommended dedicated circuit protection:

Recommended

KW Rating KW Rating Circuit Size240V 208V {Dedicated)

<4.8 KW <4.2 KW 20 Amp

4.9 KW=7.2 KW 4.2 KW=6.2 KW 30 Amp

7.3 KW-9.6 KW 6.3 KW-8.3 KW 40 Amp

9.7 KW-12.0 KW 8.4 KW-10.4 KW 50 Amp

DO NOTshorten the flexible conduit. The conduit strain relief clamp must be securely attached to thejunction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will notfit within the clamp, do not install the oven until a clamp of the proper size isobtained•

The 3 power leads supplied with this appliance are suitable for connection to heavier gauge householdwiring. The insulation of these 3 leads is rated for temperatures much higher than the temperature ratingof the household wiring. Thecurrent-carrying capacity of the conductor is governed by the wire gauge andthe temperature rating of the insulation around the wire.

Page 6: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

MAKE ELECTRICAL CONNECTIONS

A WA RNING: Sw,tchpower off at the service panel and lock the service disconnectingmeans to prevent power from being switched on accidentallg When the service disconnecting meanscannot be locked, securelU fasten a prominent warning device, such as a tag,to the service panel.

Place oven on table or platform even with the cutout opening. For a single oven, the platform must support200 Ibs.(9! kg); and for a double oven, the platform must support 375 Ibs.(170 kg). Connect the flexibleconduit to the electrical junction box as shown below*. Position the conduit in such a manner that it will liebehind the unit in a natural loop when the oven is installed. You will need to purchase an appropriate strainrelief clamp to complete the connection of the conduit to the junction box.

Junction Box

Conduit

Place Oven on a

Support to Assist inConnecting Conduit

Strain Relief Clamp(not included) Must BeUsed at Junction Box

*Ovens come equipped with a 40" long conduit. If a longer conduit is desired, there mag be one available forgour model. To check availabilitg or order parts, call !.800.GE.CARES.

[!] THREE-CONDUCTOR BRANCH CIRCUIT CONNECTIONNOTE: If residence leads are aluminum conductors, see WARNINGin Section 5, Electrical Requirements.

When connecting to a three-conductor branch circuit, if local codespermit:

A. Connect the bare oven ground conductor with the crimpedneutral (white)lead to the branch circuit neutral (white or grag incolor), using a wire nut.

B. Connect the oven red lead to the branch circuit red leadand the oven black lead to the branch circuit black leadin accordance with local codes, using wire nuts.

C. Install junction box cover.

_l__un d

Neutral

L _" Wires"-.J "_ Junction Box

Cover

181 FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTIONNOTE: If residence leads are aluminum conductors, see WARNING in Section 5, Electrical Requirements.

A. Cut the neutral (white) lead from the crimp. Re-strip the neutral (white) lead to exposethe proper length of conductor.

B. Attach the appliance grounding lead (green or bare copper)in accordance with local codes. If the residence groundingconductor is aluminum, see WARNING in Section 5.

C. Connect the oven neutral (white) lead to the branch circuitneutral (white or grog)in accordance with local codes, usinga wire nut.

D. Connect the oven red lead to the branch circuit red leadand the oven block lead to the branch circuit block leadin accordance with local codes, using wire nuts.

NOTE: If the residence red, block or white leads ore aluminumconductors, see WARNING in Section 5.

E. Install junction box cover.

'%r°e nd

unction BoxCover

[=_SLIDE OVEN INTO OPENINGo Lift oven into cabinet cutout using the

oven opening as a grip. Carefullg pushagainst oven front frame. Do not pushagainst outside edges.

Page 7: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

r_ MOUNT THE OVEN

AWAR N ING: Hount,ngscrewsmust be used. Failure to do so could result inthe oven failing out of the cabinet, causingserious injurg.

NOTE: During oven mounting step, ensure that nodamage is done to oven gasket which lines theedge of oven cavitg.

NOTE: Before drilling the pilot holes, make surethe oven is pushed as far back into the openingas it will go and is centered.

NOTE: If the cabinet is particle board, gou mustuse #8 × sA"particle board screws. These mag bepurchased at ang hardware store.

A. Drill through the mounting holes (top andbottom) of the side trim for the #8 mountingscrews provided.

B. Secure the oven cabinet with the screwsprovided.

MountingHole

Locations(hole locations

may vary)

The ScrewsMust Be aMinimum of1/4" (6 mm)From theFront ofthe Cutout.

_ BOTTOM TRIM INSTALLATION. With oven installed, attach the bottom trim through its mounting holes in front vertical brace using

two trim screws provided. Bottom trim lip must be placed under flange of bottom air duct.

SWO's and DWO installations without pedestal

DWO's with pedestals

IMPORTANT: If this unit is ever removed from the cabinet or the oven is ever pulled out for service, |

i

the bottom trim must be removed first or damage to the trim will occur. 1

Page 8: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

_OVEN RACK GUIDE INSTALLATION (IF APPLICABLE)A. Locate included oven rack guide mouting hardware.

B. Place oven rack guides on cavity wall studs with L bracket towards back of cavity as shown.

¢. Install guides using the 8 provided mounting nuts.

Oven rackguide shownin place.

_ REPLACING THE OVEN DOORNOTE:The oven door is heavy. You may need help lifting the door high enoughto slide it into the hinge slots. Do not lift the door by the handle.

A. Lift the oven door by grasping each side.

B. With the door at the same angle os the removal position (approximately1"-2" [2.5 cm-5.1 cm] from the closed position), seat the notch of the hingearm into the bottom edge of the hinge slot. The notch of the hinge arm mustbe fully seated into the bottom of the slot.

C. Fully open the door. If the door will not fully open. the indentation is notseated correctly in the bottom edge of the slot.

D. Push the hinge locks up against the front frame of the oven cavity.to the locked position.

E. Close the oven door.

Hinge inLockedPosition

JNotch of HingeSecurely Fitted Int(Bottom of HingeSlot

BottomEdge of

Slot X

! HingeJ Arm

Hinge Notch

_4-] FINAL INSTALLATION CHECKLIST, Check to make sure the circuit breaker is closed (RESET)or the circuit fuses ore replaced.

, Be sure power is in service to the building.

, Check that oil packing material and tape have been removed. Failure to remove these materialscould result in damage to the appliance once the appliance has been turned on and surfaces haveheated.

, Remove oil items from inside the oven.

, Check to be sure that the mounting screws ore installed and flush with the side trim(see Section 10).

, Check that the bottom trim is installed properly (see Section 11).

, Ensure that air duct opening at bottom of unit is free of obstructions.

, Check that oven rack guides (if applicable) ore installed correctly and oven racks function smoothly.

OPERATION CHECKLIST

,Turn on the power to the oven (refer to your Owner's Manual). Verify that the bake and broil unitsand oil cooking functions operate properly.

, See your Owner's Manual for the troubleshooting list.

, Be sure all of the oven controls ore OFF before leaving the oven.

Page 9: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

Instruccionesde instalaci6n

Hornosdeparedel ctricosempotradosde27"y30"_Preguntas? Llame al 1.800.GE.CARES(1.800.432.2737) o visite GEApptiances.com

En Canad6, liame al 1.800.561.3344 o visite www.GEAppliances.ca.

ANTES DE COMENZARLea estas instrucdones par completo g condetenimiento.

" IMPORTANTE- Guardeestasinstruccionespara el usade inspectoreslocales.

° IMPORTANT - Cumplacontodos los c6digosg ordenanzasvigentes.

• Note al instalador- AsegOresede @jar estasinstruccionescon elConsumidor.

, Note el consumidor - Conserve estasinstrucciones pare referenda futura.

, Nivel de destreze - La instalad6n de esteaparato requiere un instalador o electridstacalifieados.

, El instalador tiene la responsabilidad deefectuar una instalad6n adecuada.

, La garant[a no cubre las fallas del productoprovocadas par una instalaci6n incorrecta.

, Este producto s6lo se debe user en 6reasinteriores.

ATENCI6NINSTALADOR:T0d0s10shorn0sdeporedel&ctric0sdebenc0ntarconcabiead0dec0nexBnpermanente(cablead0direct0)dentr0deunacajadec0nexi0nesapr0badaEnestospr0ductosNOsepermiteiac0nexi6ndeltipo'enchufeyreceptacul0"

PARA SU SEGURIDAD:

A ADVERTENCIA:Antes de comenzar la instalaci6n, desconecte ,a energiadel panelde servicio g bloquee los mediosde desconexi6npara evitar el accionamiento de la energia de maneraaccidental. Cuandolos mealiesde desconexi6nde servicio no pueden bloquearse,coloque sobreel panelde servicioun dispositivode advertencia bienvisible,come una etiqueta.

Elhomo debe instalarse bienen un gabinete que se encuentre firmemente sujeto a ia estructura de ia casa. Sisecoloca pesosobre la puerta del homo, @stepuedevolcarse g provocar lesiones.Nunca permita que nadiesesuba,siente,pare o cuelgue de la puerta del homo.

Verifiqueque el revestimientode las paredes,mostradores g gabinetes ubicados alrededor del homo puedansoportar elcalor (haste 200°F[%,3°C])generado per el homo.

MATERIALESQUEPUEDENECESITAR

Cajade conexiones

Taponesde alambre

Abrazaderade aliviode tensi6npara conductode 1/2"

HERRAMIENTAS NECESARIAS

Broca de perforadora de 1/8" g perforadorael@ctricao de maneDestornillador de estrella

Alicates pelacables

INFORMACI6N DE DISE--O

INSTALACIONESDE HORNOUNICO

El homo 0nice puede instalarse solo en un gabinete o sobre un caj6n calentador. Elhomo 0nice tambi_npuede instalarse debajo de un mostrador de encimera o debajo de las estufas especificadas. Vea laetiqueta de la parte superior del homo pare consulter los modelos aprobados.

INSTALACIONESDE HORNODOBLE

Puede instalarse un homo doble solo en un gabinete o sobre un caj6n calentador. Vea la etiqueta de laparte superior del homo pare consulter los modelos aprobados.

IMPORTANTE:Siempreconsultelosinstruccionesde instalacionesindividualesenviadasconcede productoparerequerimientosespecificos.

[2_ PREPARE LA ABERTURA

NOTA: Siel gabinete no cuenta con un fondo s61ido,deben instalarse dos abrazaderas o gufas paresoportar el peso del horno. Para hornos Onieos, lasgufas o abrazaderas deben soportar 200 Ibs (91 kgs).Para hornos dobles, las gufas o abrazaderas debensoportar S7SIbs (170 kgs).

NOTA: Simarcas, imperfecdones o la aberturaresultaran visibles sabre el homo instalado, puedeser necesario agregar cutlas de madera bajo lasgufas g el reborde frontal hasta cubdr las mareaso la abertura.

NOTA: Siel gabinete no cuenta con un armaz6nfrontal g los lades son menores a un grosor de sA"(1,9cm), coloque cu_as uniformemente sobre amboslades para establecer al ancho de la abertura.

Abrazaderasadecuadaspare sostenerlas gules

Guias de 2"x 4" (5 cm x !0 cm)o equivaJentes a nivel con

el fondo del recorte

y niveladascostados de Rabertura

r_ QUITE LOS NIATERIALES DE EMPAQUENo quitar los matefiaJes de empaque puede provocar daf_os al electrodom6stico. Quite todas las partes deempaque del homo, bandejas g elementos de calentamiento. Quite la pelicula protectora g las etiquetas dela puerta exterior g panel de control. Tambi6n, quite los elementos pl6sticos de los rebordes g panel, toda lacinta que cubre el homo g los tornillos de envio que fijan el homo ala almohadilla base.Abra la puerta delhomo g quite el material informative g las bendejas del homo. Quite el reborde inferior de la parte superior delhomo. Secolocar6 al final del proceso de instalaci6n. El reborde se encuentra envuelto en forma separeda gedherido en la parte superior de la unided. Retire los deles det pedestal de Ia caja que est6 aparte g d_jetos aun costado (Hornos con Pared DoNe de 30° 0nicamente).

Page 10: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

| ABERTURAPARAHORNOSUNICOSENUNGABIENTEDEPAREDNOTA: Si el gabinete no cuenta con un armaz6n frontal g los lados son menores a un grosor de 3/4" (1,9cm),coloque cuBas uniformemente sobre ambos lados para establecer al ancho de la abertura.

Estos hornosno est6naprobodospareinstalacionesapilables.

La aberturaentre las paredesnternas debe set

Linea central Linea central

305" (77,5 cm) Ik modelo 50"i 27"(6858 cm} _1i modeb 27" !

Abertura - cumpla Abertura - cum@acon todas Cas _ con todas lasdimensi°nes g l dimensi°nes grequenm_entos J requenmrentos

""_ _"_"_ 2" (5,1 cm) rain.

Ubicanci6nde Cacaja deconexiones

(la caja deconexionespuede hallarse

en un gabineteadgancente)

_2" (55,9cm} U_*'''_"nfn. hasta Ca

parte inferiorde la caja de

onexiones

4_ _abertura 23 1/2"_--_-.L_ (59,7 cm} minimo

Nora: Deje1/4" (064 cm.}

de espaeiodesde losextremoslateraCes de

la puerta delhomo.

,,_=......_ B =======,_

tF

G

t

C

w

Ubicanci6nrecomendadade (a aberturadesde el piso52d/2" (82.6 cm}

1_2

Dimensi6n Descripci6nde la dimensi6n Homo _nico de 27" Horno _nico de 30"

A Ancho del gebinete 27" (68,6 cm) 30" (76,2 cm)B Ancho de le eberture 25" (63,5 cm) mfn. 28½" (72,4 cm) mh.

25½" (64,1 cm) m6x. 28sA" (72,7 cm) m6x.

C Altura de la abertura 27%" (70,2 cm) mfn. 27½" (69,2 cm) mfn.28½" (71,4 cm) m6x. 27s4d' (69,4 cm) m6x.

D Superposici6n del homo 1" (2,5 cm) _¼_d'(1,75 cm)sobre los costedos

laterales de la abertura

E Espacio respecto 23" (50,8 cm) min. 23" (53,3 cm) min.de esquinas adyacentes,

cajones, paredes, etc.,cuando la puerta

est_ abierta

F Superposici6n de la 1" (2,5 cm) mfn. 1" (2,5 cm) mfn.parte superior del homo (1½" (3.2 cm) para PT9050)

de la abertura

G Superposici6n de la r' (2,5 cm) m[n. 11/4" (3,2cm)perte inferior del homo

de la eberture

H Ubicaci6n de la caja 8¾" (22,2 cm) m6×. 9½" 124,1cm) m6×.de cone×iones s61o lado derecho s61o lado derecho

ABERTURAPARAHORNOSUNICOS- BAJOELMOSTRADORDEENCIMERANOTA: Estos homos s61opueden instalarse bajo los modelos especificos como se (ndica en la etiquetade la unidad.

Pueden Instalarse estufas a gas o el_ctricas sobre este homo.Ver las instrucciones de instalaci6n de la estufa para eltama_o de la aberlura.Ver la etiqueta de la parle superior del homo para Ublcaci6n de la cajamodelos aprobados, de conexiones de

240V/208V(la caja de conexiones

puede hallarse en ungabinete adyacente)

25 '* (63,5 cm) FLas conexiones de gasy el_ctricas para estufasa gas deben ubicarse enuna ubicaci6n adyaoenteaccesible sobre la derecha.

Dr:BE PODER SOSTENER 200 LBS. (90 kg) PARA HORNOS 0NICOSDEBE PODER SOSTFNER 375 LBS. (170 kg) PARA PIORNOS DOBLES

Instalaciones lado a ladoInstale dos hornos en aberturas separadas.

Linea central Linea central

30,5" (77,5 cm) modelo 30" I

2T' (68.58 cm) modelo 2T' I

i|

i-

Abertura - cum@a j Abertura -cumpla

con todas las l con todas lasdimensiones g dimensiones grequedmientos, requedmientos.

----_1 _ z' 15,icmlMin

NOTA: Una estufa puede centrarse sobre cualquierhomo en la instalaci6n de lado a lado.

22" (55,9 ore) rain. 36 *' (9t,4 cm)sobre la plataforma Altura del mostrador

de encimera

4" (10,2 cm)

-_ Placa de protecci6n

Dimensi6n Descripci6nde la dimensi6n Horno 6nico de 27" Horno 6nico de 30"

A Ancho del gebinete 25" (63,5 cm) mfn. 28½" (72,4 cm) mfn.25¼" (64,1 cm) m6x. 28%" (72,7 cm) m6x.

B Alture de le eberture 27%" (70,2 cm) mfn. 27½" (69,2 cm) mfn.28½" (71,4 cm) m6x. 27s_d' (69,4 cm) m6x.

C Superposici6n de le 1" (2,5 cm) 1" (2,5cm)unided en perte superior (1½" (3.2 cm) para PT9050)

D Superposici6n de le 1" (2,5 cm) 1VJ' (3,2cm)unided en perte inferior

E Superposici6n de le r' (2,5 cm) _¼_d'(1,75 cm)unidad en costados laterales

F Ubiceci6n de le ceje 8sA" (22,2 cm) m6x. 9½" (24,1 cm) m6x.de cone×iones s61o lado derecho s61o lado derecho

ContinUe en la secci6n 4.

Page 11: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

| ABERTURA PARA HORNOS DOBLES (2 HORNOS TI_RMICOS)NOTA:Siel gabinete no cuenta con un armaz6n frontal g los ]ados son menores a un grosor de 3/4" (1,9cm),coloque cuRas uniformemente sobre ambos lados para establecer a] ancho de la abertura.

HUbicaci6nde la caja deconexiones (la cajade cone×iones

D_

J

tF

G

tm

K

Dim. DescripcJ6n ! Homo doble de 27" Homo doble de 30" Homo doble de 30"con pedestal sin pedestal

A Ancho del gabinete 27" 168,6cm) 30" 176,2cm) 30" 176,2cm)B Ancho de la abertura 25" (63,5 cm) rain. 28½" (72,4 cm) rain. 28½" (72,4 cm) rain.

25¼" (64,1 cm) max. 28Y{' (72,7 cm) max. 28%" (72.7 cm) max.

C Altura de la abertura 49_Vld' (126,2 cm) min. 51_s/S' (131,6 cm) min. 50 ¼" (127,64cm)50Vd' (127,3 cm) max. 51_%_s" (131,9 cm) max.

D Superposici6n del 1" (2,5cm) _V_6"(1,75 cm) __d' (1,75 cm)homo sobre los

costados laterales dela abertura

E Espacio respecto de 23" (50,8 cm) min. 23" (53,3 cm) min. 23" (53,3 cm) min.esquinas adgacentes,cajones paredes, etc.,cuando la puerta est6

abierta

F Superposici6n de Io 1" (2,5 cm) min. 1" (2,5 cm) min. 1" (2,5 cm) min.porte superior del (1¼" (3.2 cm) para (1½" (3.2 cm) para

homo de Io oberturo PT95501 PT9550)

G Superposici6n de 1" (2,5 cm) min. 1¼" (3,2 cm) 1¼" (3,2 cm)la parte inferior del

homo de la abertura

H Ubicaci6n de la caja 8¾" (22,2 cm) max. 9½" (24,1 cm) max. 9½" (24,1 cm) max.de conexiones s61o lado derecho s61o lado derecho s61o lado derecho

J Altura hasta la parte 44" (111,8 cm) 47" (119,4 cm) 47" (119,4 cm)inferior de Io cojo de

conexiones

K Ubicaci6n 13¼" (33,7 cm) 12" (30,5 cm) 12" (30,5 cm)recomendada de la

oberturo desde el piso

ContinUe en la secci6n 2;.

] 0_-lsGE31-10856-1

r==i-=1_

INSTALACION CAJON|1131ABERTURA PARA SOBRE UNCALENTADOR

NOTA: InstaJe el homo s61ocon los modelos especificos %tados en la etiqueta ubicadaen la parte superior del homo.

NOTA: Pueden necesitarse espados adicionales entre las aberturas. Vefifique que los soportesdel homo sobre la ubicaci6n de caj6n calentador no obstrugan la profundidad g altura intedoresrequeddas.

Cuando instale un caj6n calentador deba]o de un homo 0nico o doble, debe instalarseun tomacorriente separado de 120V, 60 HZ con adecuada cone×i6n a tierra. Consultelas instrucdones de instalaci6n enviadas con el caj6n calentador para requisitos especfficosde instalaci6n.

81oque anti=volcadurascontra la pared traseraseg_n requisito de|eaj6n calentador

Ubicaci6nrecomendadade la aberturadesde el piso

21 5/8" (54 9 cm)

Jisitos

ContinUe a la Secci6n 3 para conocer detalles del DWO con Pedestal. De otra forma, continue a laSecci6n 4.

Page 12: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

r_ INSTALACtON DEL RIEL CON PEDESTAL (HORNOS DOBLESUNICAtVlENTE)

A. Coloque un riel con pedestal en cada rodadura del gabinete o centrado en el lado opuesto de laparte inferior del gabinete s61ido nivelado con el lateral de la abertura del gabinete. Ubique cada rielde modo que la parte frontal de los mismos se encuentre detras del lado frontal de la abertura delgabinete.

B. Realice agujeros de prueba g adjunte los deles a la rodadura o a la parte inferior del gabinete con elequipo provisto.

Page 13: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

REMOCI6N DE LA PUERTA (recomendada)NOTA: La remoci6n de la puerta no es un requedmiento de la instalaci6n del producto,

pero es una comodidad adicional.

Para quitar la puerta:

A. Abra la puerta del homo en su totalidad.

B. Presione ambas trabas de la bisagra hacia abajo endirecci6n del marco de la puerta hasta destrabarlas.Para esto puede hacer falta un destornillador delados pianos, iNO LEVANTE LA PUERTA DE LAMANIJA!

C. Coloque las manos sobre ambos lados y cierrela puerta del homo hasta la posici6n de remoci6n(aproximadamente 1"12" [2,5 cm-5,1 cm]de la posici6n de cierre).

D. Levante la puerta hasta que los brazosde la bisagra hagan salido de las ranuras.NOTA: La puerta del homo es mug pesada.Aseg_rese de tener un agarre firme antes de levantarla puerta del homo de sus bisagras. Tenga cuidadouna vez que haga quitado la puerta. No depositela puerta sobre la manUa. Esto puede provocarabolladuras o ragones.

Ranurade la bisagra

Brazode la bisagra

Posici6n

_1_ estrabada dela bisagra

La bisagra salede la ranura

[_] REQUISITOS ELI_CTRICOS

A ADVERTENCIA: steaparatadebecontarcanunaadecuadaconex, nat,erra.A ADVERTENCIA: Para prevenir un incendio o descarga el_ctrica, no utilice un cablede extensi6n con este aparato.

A ADVERTENClA: Paraprevenir una descarga el@ctrica,quite el fusible o abra elinterruptor de circuitos antes de comenzar la instalaci6n.

• , ADVERTENClA:Unaconexi6ninadecuadadecableadodom@sticodealuminioconcables de cobre puede generar un peligro el_ctrico o un incendio. S61ouse conectores dise_ados para unircobre con aluminio g siga al pie de la letra el procedimiento recomendado del fabricante.

Recomendamos que un electricista calificado conecte el cableado el@ctricode su aparato. Despu@sde la instalaci6n, solicite al electricista que le indique c6mo desconectar la energia del aparato.

Usted debe usar un sistema el#ctrico de fase 0nica de 120/208 VACo !20/240 VACde 60 hercios. Si tieneuna conexi6n con cableado de aluminio, deben utilizarse conectores adecuadamente instalados parautilizar con cableado de aluminio.

Vigentedesdeel Zdeenerode1996,elC6digoEl@ctricoNacionalrequierequelasnuevasconstrucciones(noexistentes)utilicenunaconexi6ndecuatroconductoresa unhomoel6ctrico.Cuandoinstaleunhomoel@tricoenunaconstrucci6nnueva,una casarodante,unvehiculorecreativoo un@eadondelosc6digoslocalesprohibenlaconexi6na tierra a trav@sdeunconductorneutral,consultela secci6nsobreconexionesencircuitoderivadode cuatroconductores

Consulte alas empresas de servicio p0blico sabre los c6digos el@ctricosque se aplican en su 6rea. Norealizar el cableado de su homo de acuerdo con los c6digos vigentes puede provocar una situaci6npeligrosa. Si no existen c6digos locales, el cableado g fusibles de su homo deben cumplir con el C6digoEl@ctricoNacional, NFPANo 70, 01tima edici6n, disponible en National Fire Protection Association (Asociaci6nNacional de Protecci6n contra Incendios).

[_] REQUiSiTOS ELi_CTRICOS (CONT.)Este aparato debe recibir el voltaje g frecuencia adecuados, g debe conectarse a un circuito derivadoindividual con adecuada conexi6n a tierra, protegido por un interruptor de circuitos o fusible. Ver la placa declasificaci6n ubicada en el armaz6n del homo para determinar la clasificaci6n del producto.

Rating PlateLocation .............................."

La placa de dasificaci6n se encuentra en el rebordelateral del homo.

Utilice la tabla de abajo para determinar la protecci6n de circuito dedicado minima recomendada:

Clasificaci6n Tama6o de circuitode KW Clasificaci6n de KW recomendado

240V 208V {dedicado)

<4,8 KW -<4,1 KW 20 Amp

4,9 KW-7,2 KW 4,2 KW-6,2 KW 30 Amp

7,3 KWi9,6 KW 6,3 KWi8,3 KW 40 Amp

9,7 KW-12,0 KW 8,4 KW-10,4 KW 50 Amp

NO acorte el conducto flexible. La abrazadera del alivio de tensi6n del conducto debe estar bien sujeta a lacaja de conexiones g el conducto flexible debe estar bien sujeto a la abrazadera. Si el conducto flexible noentra dentro de la abrazadera, no instale el homo hasta obtener una abrazadera del tama_o adecuado.

Los 3 cables de energ[a suministrados con este aparato son adecuados para conexiones con cableadosdom@sticosde calibre magores. La aislaci6n de estos 3 cables estc_clasificada a temperaturas mucho m6selevadas que la clasificaci6n del cableado [email protected] capacidadde transmitir corriente del conductor estc_determinada por el calibre del cable g la clasificaci6nde temperatura de la aislaci6n alrededor del cable.

Page 14: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

ELI_CTRICAS161REALICE LAS CONEXIONES

A ADVERTENCIA:Desconectelaenergiadelpaneldeserviciogbloqueelosmedios

de desconexi6n para evitar el accionamiento de la energia de manera accidental. Cuando los mediosde desconexi6n de servicio no pueden bloquearse, coloque sobre el panel de servicio un dispositivo deadvertencia bien visible, como una etiqueta.

Coloque el homo sobre una mesa o plataforma en forma nivelada con la abertura. Para un homo Onico,la plataforma debe soportar 200 Ibs.(9! kg); para un homo doble, la plataforma debe soportar 375 Ibs.(170 kg). Conecte el conducto flexible a la caja de conexiones el@trica como se indica abajo*. Posicioneel conducto de modo tal que se apoge detr6s de la unidad en un circulo natural cuando el homo seainstalado. Tendrd que comprar una abrazadera para alivio de tensi6n apropiada para completar la conexi6ndel conducto a la caja de conexiones. Caja de cone×iones

Conducto

Coloque elhornoen un sopo_e paraagudarala cone×i6n delconducto

La abrazadera del aJiviode tensi6n (no induido)debe usarse en la caja decone×Jones

*Los hornosvienenequipadosconun conductode 40"de Iongitud.Sideseaun conductom6slargo,puedehaber unodisponiblepara su modelo.Paraverificarladisponibilidado solicitarpiezas,Ilameal 1.800.GECARES.

r_ CONE×I6N DE CIRCUITO DERIVADO DE TRESCONDUCTORESNOTA:Si los cables dom_sticos son conductores de aJuminio,ver la ADVERTENCIAde la secd6n 5, Requisitos el6ctricos.

Cuando conecte un circuito derivado de tres conductores,si Io permiten los c6digos locales:

A. Conecte el conductor a tierra del homo con el cable neutral (blanco)en rizo al neutral del circuito derivado (blanco o gris) utilizando untap6n de alambre.

B. Conecte el cable rojo del homo al cable ro]odel circuito derivado g elcable negro del homo al cable negro del circuito derivado de acuerdocon los c6digos locales, utilizando tapones de alambre.

C. Instale la tapa de la caja de cone×iones.

_bles a

I_ 11 _-_ tierra g

L " neutrales_.dl" _ Tapa de

la caja aecone×iones

r_ CONEXI6N DE ClRCUITO DERIVADO DE CUATROCONDUCTORES

NOTA: Si los cables dom6sticos son conductores de aJuminio, vet la ADVERTENCIA

de la secci6n 5, Requisitos el@ctricos.

A. Corte el cable neutral (blanco) del conector de engarce.Pele el cable neutral (blanco) para e×poner la Iongitud correctadel conductor.

B. Conecte el cable a tierra del artefacto (verde o cobre)de acuerdo con los c6digos locales. Siel conductor a tierra de laresidencia es de aluminio, ver ADVERTENCIAde la secci6n 5.

C. Conecte el cable neutral (blanco) del homo con el neutralde circuito derivado (blanco o gris) de acuerdo con c6digoslocales, utiFzando un tap6n de alambre.

D. Conecte el cable rojo del horno al cable rojo del circuito derivadog el cable negro del homo al cable negro del circuito derivado deacuerdo con los c6digos locales, utilizando tapones de alambre.

NOTA: Si los cables rojos, negros o blancos son conductores dealuminio, vet ADVEIRTENCIAde la secci6n 5.

E. Ilnstale la tapa de la caja de cone×iones.

erCabrlea

Tapadelacajadecone×iones

L_J DESLICE EL HORNO DENTRO DE LA ABERTURAo Levante el homo dentro

de la abertura del gabinete utiFzandoel homo abierto como agarre. Concuidado empuje contra el armaz6nfrontal del homo. No presione sobrelos bordes e×ternos.

Page 15: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

IT_ INSTALE EL HORNO

A ADVERTENCIA:Deben utilizarse tornillos de montaje. Si no Io hace,el homo puede caer del gabinete, Io que provocariauna lesi6n grove.

NOTA: Durante el montaje del homo, asegOresede que no hag(] daflos sobre la junta del homo,que alifio el e×tremo de la cavidad del homo

NOTA: Antes de perforor los orificios piloto,asegOrese de que el homo se encuentreen la posici6n final de la abertura g centrado.

NOTA: Si el gabinete es de placa de partTculas,deben utilizarse tornillos #8 × sA" para dichomaterial. Estos pueden adquirirse en cualquierferreteria.

A. Perfore a trav6s de los orificios de montaje(superiores e inferiores) del reborde lateralpar(] los tornillos de montoje #8 provistos.

B. Asegure el gabinete del homo con los tornillosprovistos.

Ubicacionesde los

de montajeias ubicaciones

pueden variar)

Los tornillosdebenhallarse aun minimode _"(6 mm) desdeel frente dela abertura.

_ INSTALACI6N DEL REBORDE INFERIOR• Una vez instalado el homo, adjunte el borde inferior a trav6s de sus agujeros de montoje frente al

soporte vertical, utilizando los dos tornillos con cabeza recortada provistos. El labio de la cubiertainferior deber(_ ser ubicado debojo de la brida de la porte inferior del conducto de aire.

Instalaciones SWO y DWO sin pedestal

DWO sin pedestales

IIMPORTANTE: Siestounidodolgunovezse quitodelgobineteo sielhomo se quitade servicio,el Ireborde inferior debe quitorse antes o el reborde sufrir(_ doflos. 1

Page 16: Installation Instructions 27 & 30 Electric Built-inWall ......A. Place one pedestal rail on each cabinet runner or centered on opposite side of solid cabinet bottom flush with side

GUiA DE INSTALACION DE LA ESTANTERiA DEL HORNO (SlCORRESPONDE)

A. Ubique el equipo de montaje de la gufa del homo incluida.

B. Posidone el conducto de modo tal que se apoge detr6s de la unidad en un drculo natural cuando elhomo sea instalado.

C. Instale las gufas usando las 8 tuercas de montaje provistas.

Imagen de la guiade la estantedaen su lugarcorrespondiente.

_ C6MO VOLVER A COLOCAR LA PUERTA DEL HORNONOTA: La puerta del homo es pesada. Puede necesitar aguda para

levantar la puerta Io sufidente como para deslizada dentro de las ranuras dela bisagra. No levante la puerta de la manija.

A. Levante la puerta del homo tom6ndola de ambos lados.

B. Con la puerta en el mismo 6ngulo de la posid6n de remod6n(aproximadamente 1"i2" [2,5 cm-5,1 cm] desde la posid6n de cerrado),introduzca la muesca del brazo de la bisagra dentro del extremo inferior dela ranura de la bisagra. La ranura del brazo de la bisagra debe estar biencolocada en la parte inferior de la ranura.

C. Abra la puerta por completo. Si la puerta no se abre por completo,la muesca no est6 bien colocada en el extremo inferior de la ranura.

D. Presione las trabas de la bisagra hada arriba contra el armaz6n frontal dela cavidad del homo, hasta alcanzar la posid6n de trabado.

E. Cierre la puerta del homo.

Bisagra en laposid6n detrabado

/Ranura de labisagra biencolocada en laparte inferior dela ranura de labisagra

Ladoinferiorde la ranura

\

J J Brazo

ij d_ la bisagra

Ranura de la bisagra

r_ LISTA DE CONTROL FINAL DE LA INSTALACI6No Verifique que el interruptor de circuitos se encuentre cerrado (RESET)o que los fusibles del drcuito

se hagan reemplazado.

Aseg0rese de que haga suministro el6ctrico en el edifido.

Controle que se haga quitado todo el material de empaque g la dnta adhesiva. No quitar estosmateriales puede provocar daflos al electrodom6stico una vez que el aparato se haga encendido glas superficies se hagan calentado.

Quite todos los elementos ubicados dentro del homo.

Aseg0rese de que los tornillos de montaje se encuentren instalados g nivelados con el rebordelateral (ver secci6n 10).

. Verifique que el reborde inferior est6 bien instalado (versecci6n 11).

o Aseg0rese de que la abertura inferior del conducto de aire de la unidad est6 libre de obstrucciones.

. Controle que las gufas de los estantes del homo (si corresponde) est6n instaladas de forma correctag que los estantes del homo funcionen de forma fluida.

LIZTA DE CONTROL DE FUNCIONAMIENTO

. Accione la energfa del homo (consulte el Manual del propietario). Verifique que las unidadesde horneado g asado g que todas las funciones de cocd6n operen bien.

. Vet el Manual del propietario para la lista de detecci6n g soluci6n de problemas.

. Aseg0rese de que todos los controles del homo se encuentren en OFF (apagado) antesde dejar el homo.