Installation details - Teckentrup South...
Transcript of Installation details - Teckentrup South...
Subject to technical changes. 215
Corner framesoptionally with counter frame
Modular dimensionClear frame dimension
10
MW
≥ 1
00
● T90-1 „Teckentrup“● T90-2 „Teckentrup“
● T30-1/2-FSA „Teckentrup 62“
● dw 62-1/2 „Teckentrup“
● T30/T60-1/2-FSA „Teckentrup 62“● T90-1-FSA „Teckentrup 62“ ● T90-2-FSA „Teckentrup SV“
- multi-purpose:- smoke-proof:
●
●
dw 62-1/2 smoke-proof door
„Teckentrup“„RS-1/2“
(1.5 mm corner fr.)
Corner frame(optionally with counter frame) for:
Corner frame(optionally with counter frame) for:
- fire protection:
● T30-1/2-FSA „Teckentrup DF“ 62 mm● T30-1/2-FSA „Teckentrup 62 ST“● T90-1/2-FSA „Teckentrup DF“
- sound insulated: ● dw 67-1/S „Teckentrup“● dw 67-1/2 HS „Teckentrup“
Corner frame(optionally with counter frame) for:- fire protection:
Corner frame(optionally with counter frame) for:- fire protection:
Corner frame(optionally with counter frame) for:- fire protection:
- fire protection: ● T30-1-FSA „Teckentrup HT 8-D“● T30-1/2-FSA „Teckentrup 42“
- multi-purpose: - multi-purpose:● MZD-HT 8 „Teckentrup“● dw 42-1/2 „Teckentrup“
„Teckentrup“- security: ● cellar security door
● T30-1/2-FSA „Teckentrup DF“
● dw 52-1/2 „Teckentrup DF“
10 3532
32
3100
60
12
45
(dry and fast installation) = frame backfilled with mineral wool,incl. folding anchors and fixing material
Mortar-free montagefor installationin masonry/concrete
Backfilling with mineral woolWall plugs S10 H 100 RSFolding anchorsWall plugs FUR 10x160 TPlastic capAdjustable screwPlastic fixing anchor
7654321
Pos. Equipment
TSM
Modular dimensionClear frame dimension30
10 32
48
8454
10
2 (1.5)
3
33
Stai
nles
s st
eel 9
8
Modular dimension
Clear frame dimension 30
1032
48
33
2
3
73
43
10 10
Stai
nles
s st
eel 8
7
Modular dimensionClear frame dimension
1032 33
48
1062
(64) 923
2,0 (1.5)
Stai
nles
s st
eel 1
06
Sealing profile
Sealing profile
Sealing profile
Sealing profile
Sealing profile
Modular dimension
Clear structural dimension
- multi-purpose:
- fire protection:
Modular dimension
Clear frame dimension26.5
33
10.3
10
48
54
10
2 3
Closed-, counter-, shadow groove-, expansion joint- and renovation frames
Clear frame dimension
Modular dimension
10R
im w
idth
(MW
)
48
32(1.5)
32
10 32
43(5
4 or
62)
dep.
on
door
12
Closed frame forsteel doors/trap doors
Rim
wid
th (M
W)
≥ 37 79
12
Corner frame
1.5
1.5
29.5
37 (≥ 37)
15 (2
0)
Modular dimension
Clear frame dimension
Corner frame
Counter frame
Corner frame with counter frame for:- fire protection: T30-1-FSA „Teckentrup HT 8-D“ T30-1/2-FSA „Teckentrup 42“- multi-purpose: dw 42-1/2 „Teckentrup“
10
1.5
10
20
20
Clearframe dim.
(dep
. on
MW
)
Closed/Corner frame with shadow groovefor steel doors/trap doors
14
2
48
3
3243
(54
or 6
2)
14
15
10
12
Closed frame withshadow groovefor steel doors/trap doors
Modular dimension
20
9Welded on corner frame
1043
(54
or 6
2)
1514
Expansion joint
19
15
17
10
1/2
2
20
1/2
12
2
2
Expansion joint frame fordoor types 42 and 62
20
12
Prices on request
Rim
wid
th (M
W) Corner
frame
Corner-/counter frame(two-part closed frame)
Renovation frame for door type 62(only for doors without resistance class)
30
2773
63
15
115
(dep
. on
MW
)
Rim
wid
th (M
W)
Clear frame dimensionde
p. o
n do
or
dep.
on
door
Rim
wid
th (M
W)
Rim
wid
th (M
W)
Modular dim.
Subject to technical changes.
Profile 2
Profile 1
216
Counter frame withwidened part
Counter frame forall cornerframes
Technical clarificationnecessary
Block frames Type 1.1 and Type 1.2
Block frame - Type 1.1
Block frame -
Clear frame dim.Modular dimension - door
Overall frame dimension (ordering dimension)
Clear frame dim.
Modular dimension - door
Overall frame dimension (ordering dimension)
73115
73
115
42
10
10
1/2
1/2
3 (2
)
Dim
ensi
on “
X“Di
men
sion
“X“
Dim. “Y“
Dim. “Y“
1/2
1/2
Dim. “X“
Dim. “X“
Door type
Door type
40
40
Reinforced - only security doors WK 4
Mortar filling
Type 1.2
Dimension “X“ = block frame depth =Dimension “Y“ = block frame width = 115 mm
Dimension “X“ = block frame depth =Dimension “Y“ = block frame width = 115 mm
T30-1/2 FSA „Teckentrup 62“
T30-1-FSA „Teckentrup DF“ T30-2-FSA „Teckentrup DF“ T90-1-FSA „Teckentrup K“T90-1-FSA „Teckentrup 62“T90-1-FSA „Teckentrup DF“ T90-2-FSA „Teckentrup SV“ T90-2-FSRS-1/2
A „Teckentrup DF“
Fire-resistant doors
Security Smoke-proof
doors
Multi-purpose
Sound insulated
dw 52-1 „Teckentrup DF“ dw 62-1 „Teckentrup“ dw 62-2 „Teckentrup“
100
100100140140140140140
100100
100100
T60-1/2 FSA „Teckentrup 62“ 100
dw 52-1/2 „Teckentrup DF“ dw 62-1/2 „ Teckentrup” & „XL“
6584
dw 67-1/HS/S „Teckentrup“ 76dw 67-2/HS „ Teckentrup“ 76
a) mineral wool fillingor optionallyb) mortar filling(please specify when ordering)dw 67 only availablewith mortar filling
(security)
Subject to technical changes. 217
Block frames Type 2 - 5
Block frames Type 2.1/2.2 and Type 3
Additional charge: factory infilled withmineral wool (T30)or gypsum board (T90)
Type 5.1 and Type 5.3 (L) fixed with countersunk screwsType 5.2 fixed with screws (+ plastic caps)
preassembled version
Type 3
2.4 1.4peyT peyT
Type 2.1
Type 2.2
disassembledversion
Clearsize
Modular dimension - door
Overall frame dimension (ordering size)Clear structural dimension (ordering size + 10/5)
Block frame Type 4.1 Block frame Type 4.2
Block frame Type 5version for 1- and 2-leaf multi-purpose doorsdw 42-1/2 „Teckentrup“
58
0101
25
3 (2
)
3 (2
)
25
3 (2
)
42 42
58
Dim
„X“
Dim
„X“
Dim
„X“
T30 ≥
50 m
mT9
0 ≥
70 m
m
min
. 115
/175
/240
for m
ason
ry
min
. 108
/140
for c
oncr
ete
Attention - Doors with TDC: only flush installation possible.
33
10 32
≥ 5
0
1/2
1/2
Ø11.5
Ø25
37
52
56
35
≥ 5
0
≥ 50 for Type 5.1
Type 5.1Type 5.2Type 5.3
Type 5.3 L
Dim. „X“Door type Dim. „X“Door typeSmoke-proof
sound insultd.
T30/T60-1/2 FSA „Teckentrup 62“T30-1/2-FSA „Teckentrup DF“T90-1-FSA „Teckentrup K“T90-1-FSA „Teckentrup 62“T90-1/2-FSA „Teckentrup DF/SV“
Fire-resistant 100100140140140
Multi-purpose/Security
dw 52-1/2 „Teckentrup DF“
„Teckentrup“
dw 62-1/2 „Teckentrup” & “XL“
100
100
100dw 67-1/S 100
Clear frame dimension58
7348
1032
≥ 5
0
43/5
4/62
T30-1/2-FSA “Teckentrup 42“T30-1/2-FSA “Teckentrup ST“
120120120
Block frame 4.2
Dim. „X“T30T60T90 dw 52-1/2 “Teckentrup DF“dw 62-1/2 “Teckentrup“
dw 42-1/2 “Teckentrup“
120120160120120
Block frame 4.1
Frame rebate dim.Modular dimension
10
clear passagesize
(LDMW)
clear framedim. (LDZ)
50 (70)pressure-resistantspacer
Wall and ceiling connection to block frame (mortar filling)
Dim. „Y“
Dim. „Y“ Dim. „Y“
Dim. „Y“ Dim. „Y“
100 (T90 = 140)
100
100
73.5 73.5
73.5
75
100
Dim. „X“ = block frame depth = 56/73.5 mmDim. „Y“ = block frame width = 73.5 mm
Also suitable for somedoors of type 62.Technical clarificationrequired.
18
Dimension „X“ = block frame depth =Dimension „Y“ = block frame width = 100 mm
Modular dimension - doorOverall frame dimension (ordering size)
Clear structural dimension (ordering size + 10/5)
Modular dimension - door
Overall frame dimension (ordering size)Clear structural dimension (ordering dim. + 10/5)
Door typeFire-resistant
Fire-resistant
multi-purpose
multi-purp.
Dim
„X“
Dim
„X“
Dim
„X“
min
. 115
/175
/240
for m
ason
ry
min
. 108
/140
for c
oncr
ete
Dim
„X“
Dimension “X“ = block frame depth =Dimension “Y“ = block frame width = 75/100 mm
Dim. „Y“ Dim. „Y“
Subject to technical changes. 218
RS-1/2
Installationin lightweigthstud walls seepage 292
30
303
Lower connection for mounting door frames with floor recess The floor bracket is an installation aid
and can be removed after door installation,except in case of a floor-mounted door closer
30
Buffer without seal
Floor bracket for: T30-1/2-FSA „Teckentrup 42“, dw 42-1/2 „Teckentrup“
clea
r ope
ning
mod
ular
dim
.-hei
ght
clea
r ope
ning
mod
. dim
.-hei
ght
mod
. dim
.-hei
ght
clea
r ope
ning
mod
. dim
.-hei
ght
clea
r ope
ning
mod
. dim
.-hei
ght
clea
r ope
ning
mod
ular
dim
ensi
on-h
eigh
t
32
27FFL
FFL
FFL
FFL
FFL
FFL
FFL
FFLmortar
„Teckentrup“ - With buffer strip and seal(not approved for escape routes and emergency exitse)
- T30-1-FSA „Teckentrup HT 8-D“- T30-1/2-FSA „Teckentrup 42“- MZD-HT 8 „Teckentrup“- dw 42-1/2 „Teckentrup“
≥ 15
Floor connection with 4-sidedframe and 4-sided rebate for hatches and doors
With sliding threshold seal(ground sill embedded)
With sliding threshold seal(ground sill fitted)
„Teckentrup“ - double-sliding threshold seal With retractable bottom seal
> 20
Floor connection with floorbracket and 4-sided rebate for hatches and doors
Bottom door seal
Subject to technical changes. 219
FFL = Finished floor level
(Suitable for all mounting typesstarting on page 220)
220 Subject to technical changes.
Dim
ensi
on “
X”
Anchor
Mod
ular
dim
.
Cle
arop
enin
g di
m.
10 (2
0)
Dimension “X”
upper connection (at 2-leaf doors)
Wall anchor assembly (Corner frame) (Anchoring according to DIN 18093)
Dim
ensi
on “
X”
Wall plug assembly (Corner frame) (optionally mounting)
Wall plug assembly (Corner frame) (optionally mounting)
wall plug assembly corner frame (optionally mounting)
wall plug assembly corner frame (optionally mounting)
( ) - The sizes do apply to doorswith special locking
Anchor
clear frame dim.Modular dim.
10
anchor orlashing
corner frame (soffit without mounting possible)
clear frame dim.Modular dim.
Dim
ensi
on “
X”
Assembly in masonry and concrete for 62er doors
Assembly in masonry and concrete for following doors:Fire-resistant steel doors T30-1-FSA „Teckentrup 42“Fire-resistant steel doors T30-2-FSA „Teckentrup 42“
frame filled withmortar
screw connection(frame rebate) D
imen
sion
“X”
Dim. “X” (without plaster)
T30-doors/trapsDoor type
≥ 115 ≥ 100masonry
Wall typeconcrete
T90-doors/traps ≥ 140 ≥ 175
Anchor
plug-on anchor
Wall plug assembly (Closed frame) (optionally mounting)
10Dim
. “X”
Fixings on concrete and masonry
Assembly on exposed masonry for Fire-resistant-, Fire Protection-,Security-, Sound insulated- and Multi-purpose Doors
Wal
l thi
ckne
ss
Angle with plugs
10 clear frame dim.
Sliding anchor
Clear strucutral dim.
Modular dim.
clear frame dim.
Modular dim.
Assembly on exposed masonry for following doors:Fire-resistant steel doors T30-1 „Teckentrup HT 8-D“Multi-purpose steel doors MZD-HT 8 „Teckentrup“
Clear structural dim.
For using a counter frame rim width + 5 mm!
Adjustable screw
Folding anchor
folding anchor
Plastic caps
50
adjustable screw
plastic caps
10
Exposed masonry anchor pre-assembled at the factory, with adjustable srewsto compensate uneveness of the wall
Exposed masonry anchor pre-assembled at the factory, preassembled with adjustable srewsto compensate uneveness
10
with plastic fixing with plastic fixing
frame anchor
Assembly on exposed masonry for following doors:Fire-resistant steel doors T30/T60-1/2-FSA „Teckentrup 62“Fire-resistant steel doors T30-1/2-FSA „Teckentrup 62 ST“Multi-purpose steel doors dw 62-1/2 „Teckentrup“
Assembly on exposed masonry for following doors:Fire-resistant steel doors T30-1/2-FSA „Teckentrup 42“Multi-purpose steel doors dw 42-1/2 „Teckentrup“
Wal
l thi
ckne
ss
Assembly type forcorner frame standard
Assembly type for corner frame standard
Pos. 11
Assembly type for corner-/counter frame
Pos. 10
Assembly type for corner-/counter frame
Pos. 5
Assembly type forcorner frame
Wal
l thi
ckne
ss
Exposed masonry installation
Subject to technical changes. 221
screw connection(frame rebate)
Screw connection in frame rebateWeld-on assembly
10
wal
l thi
ckne
ss (W
D)
55
48 48
10
wal
l thi
ckne
ss (W
D)
wal
l thi
ckne
ss (W
D)
Modular dimension
5579
1.5
1210
10
48
Modular dimension
Clear frame dim.
Clear frame dim.
Clear frame dim.
Corner frame
Corner frame
Plastic fixing
Plastic fixing
T30-1/2-FSA „Teckentrup DF“T90-1/2-FSA „Teckentrup DF“T90-2-FSA „Teckentrup SV“
T30-1/2-FSA „Teckentrup 62“T60-1/2-FSA „Teckentrup 62“T90-1-FSA „Teckentrup 62“
wal
l thi
ckne
ss (W
D)
10Door leaf Door Leaf
Door leaf
Folding anchor
T30-1/2-FSA „Teckentrup 42“
≥ 68
alternatively: pluggedanchor brackets countersunk laterally
anchor bracketscountersunk laterally
Door leaf(T90-2 “SV” = thin rebate)
48
Doors without counter frame: fixing as shown(without counter frameand anchor brackets)
Wall-plug mounting - rear frame piece Closed frame/ Corner-, Counter frame/Counter frame with widened part
Installation in autoclaved aerated concrete walls
Door typeAutoclaved aerated concrete in accordance with DIN 4165, strength class G4 or GP4
T30-1-FSA „Teckentrup 42“ wall thickness (WD) ≥115 ≥150 wall thickness (WD) ≥115 ≥150T30-1-FSA „Teckentrup 62“ wall thickness (WD) ≥115 ≥150 wall thickness (WD) ≥115 ≥150T30-1-FSA „Teckentrup 62 ST“ wall thickness (WD) ≥115 ≥150 wall thickness (WD) ≥115 ≥150T30-2-FSA „Teckentrup 42“ wall thickness (WD) ≥115 ≥150 wall thickness (WD) ≥115 ≥150T30-2-FSA „Teckentrup 62“ wall thickness (WD) ≥115 ≥150 wall thickness (WD) ≥115 ≥150T60-1-FSA „Teckentrup 62“ wall thickness (WD) ≥150 wall thickness (WD) ≥150T60-2-FSA „Teckentrup 62“ wall thickness (WD) ≥150 wall thickness (WD) ≥150T90-1-FSA „Teckentrup 62“ wall thickness (WD) ≥175 wall thickness (WD) ≥175T30-1/2-FSA „Teckentrup DF“ wall thickness (WD) ≥175 wall thickness (WD) ≥175T90-1-FSA „Teckentrup DF“ wall thickness (WD) ≥200 wall thickness (WD) ≥200T90-2-FSA „Teckentrup SV“ wall thickness (WD) ≥200 wall thickness (WD) ≥200T90-2-FSA „Teckentrup DF“ wall thickness (WD) ≥200 wall thickness (WD) ≥200
reinforced cellular concrete slabs with general technical approval, strength class G4
222 Subject to technical changes.
224
Fire-resistant, smoke-proof doors in lightweight stud wallsFitting in assembly walls
The installation in lightweight stud walls requires a special counter or closed frame and a top door closer.Supporting walls must be ensured that the door or the door structure is not affected.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16T30-1 „Teckentrup HT 8-D“ • • • • • • • • • • • • • • • •
„Teckentrup 42“ • • • • • • • • • • • • • • • •„Teckentrup 62“ • - • • - - - - - - • - - • - -„Teckentrup DF“ • • • • • • • • • • • • • • • •„Teckentrup 62 ST“ • - • • - - - - - - • - - • - -
T60-1 „Teckentrup 62“ • - • • - - - - - - • - - • - -T30-2 „Teckentrup 42“ • • • • • • • • • • • • • • • •
„Teckentrup 62“ • - • • - - - - - - • - - • - -„Teckentrup DF“ • • • • • • • • • • • • • • • •„Teckentrup 62 ST“ • - • • - - - - - - • - - • - -
T60-2 „Teckentrup 62“ • - • • - - - - - - • - - • - -T90-1 „Teckentrup 62“ • - - - - - - - - • • - - • • -
„Teckentrup DF“ • - • • • - - • • - - - - • • -T90-2 „Teckentrup SV“ • - • • • - - • • - - - - • • -
„Teckentrup DF“ • - • • • - - • • - - - - • • -
• • • • • • • • • • • • • • • •
Assembly wall ProducerPos. with DIN 4102-4 table 48 wall with studs between GKF-Platten
1 with DIN 18180 or gypsum boardKnauf - wall with studs between „Knauf-Massivbauplatten“ for each side 1x25 mm;
2 W353 test certificate Nr. P-3202/2028-MPA BSW112/W115 wall with studs between „Knauf-Feuerschutzplatten“ for each side 2x12,5 mm;
3 W116 test certificate Nr. P-3310/563/07-MPA BSRigips - wall with studs between„Rigips-Platten“ for each side 2x12,5 mm;
4 3.40.04 test certificate Nr. P-3956/1013-MPA BS 3.40.04-06 wall with studs between „Rigips-Platten“ for each side 2x12,5 mm;
5 3.41.01-04 test certificate Nr. P-3956/1013-MPA BSwall with studs between „Rigips-Platten“ for each side 1x25 mm;
6 3.40.09 test certificate Nr. P-3014/1393-MPA BS wall with studs between „Rigips-Platten“ for each side 1x20 mm (or1x25 bzw. 1x20 u. 1x12,5mm); test certificate Nr. P-3014/1393-MPA BS 7 3.60.20
Fermacell wall with studs between „Fermacell-Platten“ for each side 1x2,5 /1x10mm;8 1 S 31 test certificate Nr. P-3274/335/14-MPA BS
wall with studs between „Fermacell-Platten“ for each side 2x12,5 mm;9 1 S 31 test certificate Nr. P-3274/335/14-MPA BS
PROMAT - wall with studs between „PROMATECT-H-Platten“ for each side 1x15 mm; 10 450.70 test certificate Nr. P-MPA-E-98-099 Promatect-H Wand
wall with studs between „PROMATECT-H-Platten“ for each side 1x20 mm; 11 450.81 test certificate Nr. P-MPA-E-99-047 Stahlfachwerkwand
wall with studs between „Promaxon-Platten“ for each side 1x15 mm; 12 150.70 test certificate Nr. P-3912/6000-MPA BS
Siniat - wall with studs between „Siniat-Platten“ for each side 1x25 mm; 13 test certificate Nr. P-3515/0519-MPA BS
wall with studs between „Siniat-Platten“ for each side 1x25 mm; 14 test certificate Nr. P-SAC-02/III-681
wall with studs between „Siniat-Platten“ for each side 2x12,5 mm; 15 test certificate Nr. P-SAC-02/III-681
wall with studs between „Siniat-Platten“ for each side 1x20 mm; 16 test certificate Nr. P-MPA-E-98-005
Smoke-Proof door RS-1/RS-2
see pos. no.:
≥ 100
Max. wall heights Wall thickness
assembly walls Suitable for installation in:
≥ 100
≤ 4000
≤ 3000
≥ 150
≤ 5000 ≥ 150
≤ 5000
≥ 100
≤ 5000 ≥ 100
≥ 100
≥ 100≤ 5000
≤ 5000
≤ 5000
≤ 5000 ≥ 100
≤ 5000 ≥ 100
≥100≤ 4000
≤ 5000
≤ 5000
≤ 5000 ≥ 100
≥ 95
≥ 80
≥ 84
≥ 150
≤ 3000
≤ 5000
Type of door
Subject to technical changes.
1 2 3 4 5 6 7 8T30-1 „Teckentrup HT 8-D“ - - - - - - - -
„Teckentrup 42“ - - - - - - - -„Teckentrup DF“ - - - - - - - -„Teckentrup 62“ - - - - - - - -„Teckentrup 62 ST“ - - - - - - - -
T60-1 „Teckentrup 62“ - - - - - - - -T30-2 „Teckentrup 42“ - - - - - - - -
„Teckentrup DF“ - - - - - - - -„Teckentrup 62“ - - - - - - - -„Teckentrup 62 ST“ - - - - - - - -
T60-2 „Teckentrup 62“ - - - - - - - -T90-1 „Teckentrup 62“ • • • • • • • •
„Teckentrup DF“ - • • • • • • •T90-2 „Teckentrup SV“ - • • • • • • •
„Teckentrup DF“ - • • • • • • •- - - - - - - -
PROMAT- wall with studs between „PROMATECT-H-Platten“ for each side 1 x 15 1 450.90 and 1 x 8 mm; test certificate Nr. P-3255/1459-MPA BS
wall with studs between „PROMATECT-H-Platten“ for each side 1 x 15 2 450.95 test certificate Nr. P-3796/7968-MPA BS
Knauf - wall with studs between „Knauf-GKF-Platten“ for each side 1 x 20 + 1 x 3 W131 12,5 mm + 0,5 mm sheet steel; test certificate Nr. P-3391/170/08-MPA BS
wall with studs between „Knauf-GKF-Platten“ for each side 3 x 12,5 mm + 4 W131 0,5 mm sheet steel; test certificate Nr. P-3391/170/08-MPA BS
wall with studs between „Knauf-Firebord“ for each side 2 x 15 mm + 0,5 mm5 W132 sheet steel; test certificate Nr. P-3391/170/08-MPA BS
Rigips - wall with studs between „Rigips-GKF-Platten“ for each side 2 x 20 mm;6 TB 6.50.00 test certificate Nr. P-3021/0119-MPA BS
wall with studs between „Rigips-Vario-Bauplatten“ for each side 1 x 12,5 and 20 mm; test certificate Nr. P-3020/0109-MPA BS7 SB 6.70.10
Siniat - wall with studs between „Siniat Gipskartonplatten“ for each side 2 x 15mm +2 x 0,26mm sheet steel, test certificate Nr. P-3391/0890-MPA BS 8
assembly firewalls (F90)
≤ 5000
≤ 5000
≤ 5000
≤ 5000
≤ 5000
≤ 5000
≥ 130
≥ 142
≥ 116
≥ 126
≥ 161
≥ 130
≥ 166
≥ 161
≤ 4000
≤ 5000
225
Fire-resistant, smoke-proof steel doors in lightweight stud wallsFitting in assembly firewalls (F90)
Type of door
Smoke-Proof door RS-1/RS-2
Assembly firewalls ProducerPos. Max. wall heights Wall thickness
Subject to technical changes.
see pos. no.:Suitable for installation in:
The installation in lightweight stud walls requires a special counter or closed frame and a top door closer.Supporting walls must be ensured that the door or the door structure is not affected.
≥ 10
0
10Countersunk screwsCorner frame
Filling (mineral wool/gypsum)*
Fitting in lightweight construction stud wallsAssembly walls (F90)
Approved doors see table page 224-225
Technical drawing
Drawn GKF-structural panel wall
Drawn GKF-structural panel wall
Countersunk screws
7542
10
Modular dimension
Standard + 10 mm around M. d.
Clear frame dimension
Modular dimension
Clear frame dimension
Closed frame(quick-fit frame)
10
10
12
* Gypsum board (T90-1 DF)or mineral wool (T30)
Door leaf
Counter frame
791045
≥ 10
0
* Alternatively, the backfilling with mortar is permissible
Doors for the installation inAssembly walls (F90)GKF-construction boards as per DIN 4102 part 4 paragraph 4.10 Tab. 48Knauf-assembly wall (F90)Test certificate No. P-3202/2028-MPA BS No. P-3070/0609-MPA BSRigips-assembly wall (F90)Test certificate No. P-3956/1013-MPA BSNo. P-3213/2038-MPA BSNo. P-3700/7008-MPA BSNo. P-3696/6968-MPA BS
Fermacell-assembly wall 1 S 31 (F90)Test certificate No. P-3361/2519-MPA BSPROMAXON-Montagewand (F90)Test certifivate No. P-3912/6000-MPA BSSiniat-assembly wall (F90)Test certificate No. P-MPA-E-98-005No. P-MPA E-99-020No. P-MPA-E-99-021No. P-3515/0519-MPA BS
Door closer and counter-/closed frameare always required for installation inassembly walls (F90).
Door leaf
Dim
. „X
“ (≥
161)
Wal
l thi
ckne
ss 1
25 m
m
5
5
10
Mineral wool
Dim
. „X
“ (12
5 - 1
60)
only T30-1 „Teckentrup 62“ T30-1 „Teckentrup 62 ST“ T30-2 „Teckentrup 62“ T30-2 „Teckentrup 62 ST“
Modular dim.+ 76 mm
75 7542 42
Closed frame(quick-fit frame)
Wal
l thi
ckne
ss
226 Subject to technical changes.
Promatect-H-profile stud wall (F90) /Promatect-H-steel framework wall (F90)
227
Modular dimension
Clear frame dimension
Modular dimension
Clear frame dimension
Closed frame(quick-fit frame)
Closed frame(quick-fit frame)
Door leaf
Door leaf
Counter frame
Counter frame
Countersunk screws
Profile stud wall
Countersunk screwssteel framework wall
„PROMATECT-H“ 10 thick
PROMATECT-H board
PROMATECT-H Platte
countersunk screws
„PROMATECT-H“ 8 thick
corner frame
10 10
10
10
10
12
84
42 4575 79
45457979
* Gypsum filling (Alternatively, the backfilling with mortar is permissible)
* Gypsumfilling, (Alternatively, the backfilling with mortar is permissible)
* Gypsum board
Standard + 10 mm around MD
Standard + 10 mm around MD
Countersunk screws
Profile stud wallCountersunk screws
„PROMATECT-H“ 10 thick
„PROMATECT-H“ filling:optionally with mineral fibre plates
„PROMATECT-H“ filling:optionally with mineral fibre plates
Corner frame
84
Gypsum filling on site
10
Doors for the installation inPromatect-H-profile stud wall (F90)Test certificate No. P-MPA-E-98-099
Doors for the installation inPromatect-H-steel framework wall (F90)Test certificate No. P-MPA-E-99-047 bzw. P-MPA-E-99-044
10
10
Approved doors see table page 224-225
Subject to technical changes.
Fitting in lightweight construction stud walls
Mineral woolROCKWOOLRP X 40 thick
CW-profile75 x 0.6 /For closedframe:U-profile≥ 50 x 40 x 2
U-50 steel profile
Door closer and counter-/closed frameare always required for installation in Promatec-H-walls.
Door closer and counter-/closed frameare always required for installation in Promatec-H-walls.
Promat-fire wall (F90)
Modular dimension
Clear frame dimensionCountersunk screws
* Gypsum filling (Alternatively, the backfilling with mortar is permissible)
Countersunk screws
„PROMATECT-H“ 8 thick
„PROMATECT-H“ 8 thick
Door leaf
Closed frame(quick-fit frame)
„PROMATECT-H“ 10 thick
Counter frame
„PROMATECT-H“ filling: optionally withmineral fibre plates
Promat-fire wallPromat-fire wall
Standard + 10 mm MD
Doors for the installation inPromat-fire wall (F90)Test certificate No. P-3255/1459-MPA BS
Door closer and counter-/closed frame are always required for installation in Promat-fire walls.
≥ 13
0
≥ 13
0
4579
1042
75
10
10
12
228 Subject to technical changes.
Countersunk screws
Corner frame
Fitting in lightweight construction stud walls
Approved doors see table page 224-225
Closed frame(quick-fit frame)
Counter frame
Fixing clipsFixing bracketSpacers
Corner frameDoor leaf
*Alternative the backfilling with mortar is permissible.
*Gypsum boardRigips-fire wall SB
Rigips-fire wall SB
Countersunk screwsCountersunk screws
„Gypsum board“, GKBDIN 18180; 9.5 thick
Filled withmineral fibre plates
166
166
4210
10
12
75 7945
10
10
10
3
Fitting in lightweight construction stud wallsRigips-Fire wall TB (F90)Rigips-Fire wall SB (F90)
Doors for the installation inRigips-fire wall TB (F90)Test Certifictate No. P-3021/0119-MPA-BS
For the installation in Rigips-fire walls a door closer and a counter/closing frame is necessary.
Doors for the installation inRigips-fire wall SB (F90)Test certificate No. P-3020/0109-MPA-BS
For the installation in Rigips-fire walls a door closer and a counter/closing frame is necessary.
Modular dimension
Clear frame dimension
Closed frame(quick-fit frame)
Counter frame
Corner frameDoor leaf
*Gypsum filling
*Gypsum filling
*Alternatively, the backfilling with mortar is permissible.
*Gypsum board
Rigips-fire wall TB
Countersunk screwsRigips-fire wall TB
Countersunk screws
„Gypsum board“, GKB DIN 18180; 9,5 thick
Filled withmineral fibre plates
794542
10
10
10
12
130
130
75
10
10
10
3
Standard + 10 mm MD
229Subject to technical changes.
Approved doors see table page 224-225
Modular dimensionClear frame dimension
Standard + 10 mm MD
Fixing clipsFixing bracketSpacers
Fitting in lightweight construction stud wallsKnauf-assembly fire wall (F90)Siniat-assembly fire wall (F90)
„Gypsum board“, GKB DIN 18180; 9.5 mm
„Gypsum board“, GKB DIN 18180; 9,5 mm
Filling optionally withmineral fibre plates
*Gypsum board
*Gypsum board
Siniat GipsplattenType GKF 15 s+
Siniat gypsum boardType GKF 15 s+
Doors for the installation inKnauf-assembly fire wall (F90)Test Certifictate No. P-3073/0639-MPA-BSTest Certifictate No. P-3074/0649-MPA-BS
For the installation in Knauf-assembly fire wall a door closer and a counter/closing frame is necessary
Doors for the installation inSiniat-assembly fire wall (F90)Test Certifictate No. P-3391/0890-MPA-BS
For the installation in Siniat-assembly fire wall a door closer and a counter/closing frame is necessary
12
Countersunk screws
Countersunk screws
Modular dimension
Clear frame dimension
Counter frame
Door leafCorner frame
Door leafCorner frame
*Alternatively, the backfilling with mortar is permissible.
*Gypsum board
*Alternatively, the backfilling with mortar is permissible.
10
1010
10
10
10
Standard + 10 mm all-round MD
75 7942 45
Closed frame(quick-fit frame)
Counter frameClosed frame(quick-fit frame)
Galvanized sheet steel 0.26 mm
Knauf fire-proof plates 12.5 mm (2 x 15 mm, 12.5 + 20 mm)
7945
10
10
230 Subject to technical changes.
Approved doors see table page 224-225
Modular dimensionClear frame dimension
Standard + 10 mm all-round MD
CW profile100-06