Insight Lighting Analysis Help

84
1.1 1.2 1.3 1.4 1.4.1 1.4.2 1.4.3 1.4.4 1.4.5 1.4.6 1.4.7 1.5 1.5.1 1.5.2 1.5.2.1 1.5.3 1.6 1.7 1.7.1 1.7.2 1.7.2.1 1.7.3 1.7.3.1 1.7.3.2 1.7.4 1.7.5 1.7.6 1.7.6.1 1.7.6.2 1.8 Table of Contents Introduction About Insight Lighting Analysis Requirements Workflows Overview LEED Studies (Single point in time) LEED sDA & ASE Studies (Annual simulation) Solar Access Custom Illuminance Studies (Single point in time) Including Electric Lighting Perspective Illuminance Renderings Managing Results Accessing & Saving Results Analysis Display Settings Customizing Analysis Visual Styles Room Parameters Best Practices Additional Settings & Considerations Model Requirements Views & Schedules Design Options Material Settings Transparent Materials Opaque Materials Light Analysis Settings Sky Models Analysis Costs Cloud Credit Pricing Manage Cloud Credit Costs Validation 1

Transcript of Insight Lighting Analysis Help

Page 1: Insight Lighting Analysis Help

1.1

1.2

1.3

1.4

1.4.1

1.4.2

1.4.3

1.4.4

1.4.5

1.4.6

1.4.7

1.5

1.5.1

1.5.2

1.5.2.1

1.5.3

1.6

1.7

1.7.1

1.7.2

1.7.2.1

1.7.3

1.7.3.1

1.7.3.2

1.7.4

1.7.5

1.7.6

1.7.6.1

1.7.6.2

1.8

TableofContentsIntroduction

AboutInsightLightingAnalysis

Requirements

Workflows

Overview

LEEDStudies(Singlepointintime)

LEEDsDA&ASEStudies(Annualsimulation)

SolarAccess

CustomIlluminanceStudies(Singlepointintime)

IncludingElectricLighting

PerspectiveIlluminanceRenderings

ManagingResults

Accessing&SavingResults

AnalysisDisplaySettings

CustomizingAnalysisVisualStyles

RoomParameters

BestPractices

AdditionalSettings&Considerations

ModelRequirements

Views&Schedules

DesignOptions

MaterialSettings

TransparentMaterials

OpaqueMaterials

LightAnalysisSettings

SkyModels

AnalysisCosts

CloudCreditPricing

ManageCloudCreditCosts

Validation

1

Page 2: Insight Lighting Analysis Help

1.9

1.9.1

Support&FAQ

Troubleshooting

2

Page 3: Insight Lighting Analysis Help

InsightLightingAnalysisHelpThisguidecoverstheInsightLightingAnalysiswithRevit2017workflowsavailablewithInsightpluginv3.0.0.

AdditionalRevitsupport.

Introduction

3

Page 4: Insight Lighting Analysis Help

AboutInsightLightingAnalysisInsightLightingAnalysiswithRevitprovidesincontextdaylightingandlightinganalysisresultsandautomatedschedulingtohelpyoudocumentlightlevelsthroughoutyourdesign.Thepluginprovidesautomatedsettingsforspecificstudytypes,aswellascustomizableoptions.Thefollowinganalysistypesarecurrentlyavailable:

AnalysisType Description

IlluminanceAnalysis Fullcustomcontroloverdate,time,threshold,andanalysisplaneheight

DaylightAutonomy(sDApreview)

SamplecalculationforLEEDv4EQc7opt1(sDA&ASE)Reducedcost&calculationtime

LEED2009IEQc8opt1 AutomatedsettingsforLEED2009IEQc8opt1settings

LEEDv4EQc7opt1 AutomatedsettingsforLEEDv4EQc7opt1(sDA&ASE)settings

LEEDv4EQc7opt2 AutomatedsettingsforLEEDv4EQc7opt2settings

SolarAccess Customizablehoursofsunstudy

InsightLightingAnalysiswithRevitleveragestheA360Renderingservice,acloudbasedrenderingservice,toprovidequickandaccuratelightinganalysisresults.ThediagrambelowrepresentshowInsightLightingAnalysiswithRevitworks.

AboutInsightLightingAnalysis

4

Page 5: Insight Lighting Analysis Help

AboutInsightLightingAnalysis

5

Page 6: Insight Lighting Analysis Help

RequirementsInsightLightingAnalysisissupportedforRevit2016andabove.MorerecentversionsofRevitwilloftenfeaturemorefunctionality.RefertotheInsightLighting&SolarAnalysisForumforavailableversionsandfunctionalities.

AccessrequirementsforusingInsightLightingAnalysiswithRevit:

AutodeskRevit2016oraboveMostrecentInsightpluginAccesstoaRevit,BuildingDesignSuite,orAECCollectionssubscriptionCloudCreditsifconductinglargeranalysesProxySettings:HereisthelistofproxiesandportsthatshouldbeopenedtoallowunhindereduseofRenderingandLightingAnalysis

*.akamaiedge.net*.amazonaws.com*.autodesk.com*.google-analytics.com*.cloudfront.net*.getsatisfaction.com

Firewallsshouldallowports80and443toeverythingifpossible.

Domainsapi.autodesk.commetering.autodesk.comraas2.autodesk.comrendering.cloud.autodesk.comrendering.360.autodesk.com

Learnaboutmodelrequirementshere.

Requirements

6

Page 7: Insight Lighting Analysis Help

WorkflowsRegardlessofthetypeofanalysisyouwishtodo,togetstartedwithInsightLightingAnalysiswithRevit,youshould:

1. InstallthemostrecentversionoftheInsightplugin.Findoutwhichversionsareavailablehere.

2. Prepareyourmodel:Settheprojectlocationandselectaweatherstation.Definesurfacereflectivityandglazingmaterialproperties.

Fromthereyouwillbepreparedtocompleteanyoftheworkflowsoutlined.

Workflows

7

Page 8: Insight Lighting Analysis Help

OverviewThisvideoshowsaquickoverviewofInsightLightingAnalysis:AutodeskInsightLightingAnalysis.

OpenabuildingelementmodelinRevit.NotethatforlightinganalysisstudiesyoumustuseabuildingelementRevitmodel.Aconceptualmassmodelwillnotwork.AlsobesuretologintoyourA360account.LightinganalysisconsumesCloudCredits,soRevitwillneedtobeabletoaccessyourA360accounttocompletetheanalysis.

Fornewprojects,makesurethatyourlocationissetandaweatherstationisselected.

FromtheAnalyzetab,selectLightingfromwithintheInsightpanel.TheLightingcommandisaseparatepluginyoucandownloadfromhere.

Thefirstdialogthatappearsprovidesresourcesandbestpracticesforconductingalightinganalysisstudy.Thesebestpracticesarenotrequired,butwillhelpyouachievemoreaccurateresults.SelectContinue.

Next,youwillhavetheoptiontorunanewanalysistypeorrecallpreviouslysavedresults.SelectRunNewAnalysisandthenGo.

Overview

8

Page 9: Insight Lighting Analysis Help

TheLightingAnalysisintheClouddialogboxwillallowyoutocontrolyourstudysettings.

Overview

9

Page 10: Insight Lighting Analysis Help

A.Analysisallowsyoutoselectbetweendifferentstudytypesincluding:

AnalysisType Description

IlluminanceAnalysis Fullcustomcontroloverdate,time,threshold,andanalysisplaneheight

DaylightAutonomy(sDApreview)

SamplecalculationforLEEDv4EQc7opt1(sDA&ASE),Reducedcost&calculationtime

LEED2009IEQc8opt1 AutomatedsettingsforLEED2009IEQc8opt1settings

LEEDv4EQc7opt1 AutomatedsettingsforLEEDv4EQc7opt1(sDA&ASE)settings

LEEDv4EQc7opt2 AutomatedsettingsforLEEDv4EQc7opt2settings

SolarAccess Customizablehoursofsunstudy

Overview

10

Page 11: Insight Lighting Analysis Help

B.SelectwhichLevelsyouwouldliketovisualizeresultsfor.Dropdownthemenu,anddoubleclickonyourselection.Toselectmultiplelevels,holddownSHIFT,selectthelevels,thenclickoutsideofthedropdownmenu.

NotethatCloudCreditcostsaretiedtofloorareaincludedintheanalysis.LearnmoreaboutCloudCreditcosts.

C.TheEnvironmentsettingsincludeLocationandanalysistimeorrange.TheLocationspecifiedfortheRevitprojectiswhatwillbeusedfortheanalysis.ThedateandtimesettingsareautomaticallypopulatedforLEEDanalysistypes,howeverifyouselectIlluminanceAnalysisorSolarAccess,youhavetheabilitycontrolyoursettings.

D.IlluminanceSettingsarealsoautomaticallypopulatedbasedonLEEDcriteria,butcanbemanuallycontrolledforIlluminanceAnalysisandSolarAccessstudies.

E.Resolutionincludestwoanalysisgridsizes;a72inchgridand12inchgridandalsodrivescloudcreditcosts.Forsomeanalysistypes,thesegridsizesarepresetandcannotbeedited.

NotethatCloudCreditcostsaretiedtoanalysisresolution.LearnmoreaboutCloudCreditcosts.

F.SelectStartAnalysistobeginthesimulation.Cloudcreditswillnotbechargeduntiltheanalysisiscomplete.

AfterselectingStartAnalysis,themodelgeometrywillbeuploadedtothecloudrenderingengine.DonotclosetheprojectorRevitduringthisprocess.

Oncethemodelissuccessfullyuploadedtothecloudandtheprojectissaved,itisokaytoclosetheprojectorcontinueworkinginRevit.Notethatanychangesyoumaketothemodelgeometryormaterialsettingswillnotbereflectedinyouranalysisresults,asthemodelhasalreadybeenuploadedforanalysis.

Youcanchecktheprogressoftheanalysisbyinitiatingthepluginagain,andusingthedropdownmenutofindinprogressanalyses.

Overview

11

Page 12: Insight Lighting Analysis Help

Revitwillnotifyyouoncetheresultsareready.AcceptorDeclinethecloudcreditchargesatthispoint.Itisrecommendedyoualsosavetheprojectafteracceptingthecharges,soyouwillbeabletorecallthelightinganalysisresultsafterexitingRevit.

Overview

12

Page 13: Insight Lighting Analysis Help

Openthe_LightingAnalysisModelViewunder3DViews(oranyother3Dview).Notethatany“_Lighting…”viewsareautomaticallycreatedtoeasilyaccessresultsinplan,3D,andasaschedule.Analysisresultswillpopulateinwhatever3Dviewiscurrentlyactive.

FromtheInsight360panelselectLightingtoaccessyouranalysisresults.Thistime,selecttheresultsfortheanalysisthathasbeencompletedandselectGo.

Overview

13

Page 14: Insight Lighting Analysis Help

You’llbepromptedwithadialogboxwithasummaryofyourresults.IfyouaredoingaLEEDtypeanalysis,thentheamountofachievablepointswillalsobeincluded.

UsetheSectionBoxtoviewtheresultsin3Doropenthecorresponding“_Lighting”floorplan.

Overview

14

Page 15: Insight Lighting Analysis Help

Overview

15

Page 16: Insight Lighting Analysis Help

Notethat“_Lighting”floorplansareonlyproducedifroomsareplacedforthelevels.

Foranalysistypesthatrepresentasinglepointintime,youcantogglebetweenthetwodatesandtimesthatweresimulatedbyselectingtheanalysisplane,andchangingtheAnalysisConfigurationinthePropertiespanel.

Open_LightingAnalysisRoomSchedule.Ifyoudefinerooms,thoseroomsandcorrespondinganalysisvalueswillbepopulatedhere.

Anychangesmadeinthescheduledonotrequireyoure-runtheanalysis.SimplyselectLightingandaccessthestudyresultstoregenerateresultsconsideringtheinformationupdatedintheschedule.

Overview

16

Page 17: Insight Lighting Analysis Help

LEEDStudies(Singlepointintime)YoucanuseInsightLightingAnalysistodetermineyourdesign’sprogresstowardsachievingLEEDdaylightingcriteria,specificallyLEED2009IEQc8opt1andLEEDv4EQc7opt2.Bothofthesecreditsrequirespecificilluminancelevelsattheequinoxes.

Toconducteitherofthesestudies,followthestepsoutlinedintheOverviewandtakenoteofthefollowing.

WhenselectingeitherLEEDanalysistype,notethatthemajorityoftheanalysissettingsarepresetaccordingtotheLEEDspecifications.

A.TheLocationissetbasedontheRevitprojectlocation.

LEEDStudies(Singlepointintime)

17

Page 18: Insight Lighting Analysis Help

AnalysisType Description

LEED2009IEQc8opt1

AsdefinedbyUSGBC,thissimulationrequiresaclearskyconditionwithin15daysofSeptember21at9amand3pm.

LEEDv4EQc7opt2

AsdefinedbyUSGBC,thissimulationrequiresaclearskyconditionandusesaverageweatherdatawithin15daysofSeptember21andMarch21.

LEEDsinglepointintimeanalysistimesautomaticallyusethePerezSkymodel.

B.LEED2009andv4specifydifferentthresholds,soyouwillseethesevalueschangedependingonwhichversionofLEEDyouchoosefortheanalysistype.Additionally,LEEDrequirestheanalysisoccurat30inchesabovethefinishedfloor.TheanalysisplaneautomaticallyisgeneratedatthisheightforLEEDstudies.

WhenyougeneratetheresultsinyourRevitmodel,youwillalsogetasummaryofpercentageofroomspassingandestimatedLEEDcreditpointstheprojectiseligiblefor.

Itisoftenthecasethatyouwillwanttoexcluderoomsthatarenotregularlyoccupiedfromtheanalysissonottoskewyourresults.Youcancontrolthisthroughtheschedule.

AutomatedShadesarealsoavailabletoincludeandwillextendtheacceptancethreshold.

LEEDStudies(Singlepointintime)

18

Page 19: Insight Lighting Analysis Help

Anychangesmadeinthescheduledonotrequireyoure-runtheanalysis.SimplyselectLightingandaccessthestudyresultstoregenerateresultsconsideringtheinformationupdatedintheschedule.

LEEDStudies(Singlepointintime)

19

Page 20: Insight Lighting Analysis Help

LEEDsDA&ASEStudies(Annualsimulation)YoucanuseInsightLightingAnalysistoproducesDAandASEresultsaccordingtoLEEDv4EQc7opt1.Thiscreditrequiresannualsimulationatanhourlytimestep.

Toconductthisstudies,followthestepsoutlinedintheOverviewandtakenoteofthefollowing.

SimilartotheLEEDstudiesforasinglepointintime,manyofthesettingsforthisanalysistypeareautomaticallypredefined.

LEEDsDA&ASEStudies(Annualsimulation)

20

Page 21: Insight Lighting Analysis Help

A.Thetimerangewillbeautomaticallysettoafullannualsimulation,from8amto6pm.LEEDsDAandASEstudiesautomaticallyusethePerezSkymodel.

B.PertheLEEDrequirements,sDA300/50foratleast55%or75%regularlyoccupiedfloorareaisachieved.Additionally,ASE1000/250ofnomorethan10%fortheoccupiedfloorareathatisdaylitpersDA300/50.LEEDrequirestheanalysisoccurat30inchesabovethefinishedfloor.TheanalysisplaneautomaticallyisgeneratedatthisheightforLEEDstudies.

C.sDAandASEcalculationsrequireat24inchanalysisgrid,whichisautomaticallyset.

SincethesDAandASEsimulationismoreintensivethanasinglepointintime,theanalysiswillcostmoreCloudCreditsandtakemoretimethanasinglepointintimeanalysis.SelectCheckPricebeforesubmittingthemodelforanalysistoseetherequirednumberofcloudcreditsfortheanalysis.

ResultssummarieswillprovideguidanceonhowtoimprovedesigntoachieveLEEDrequirementsaswellasmoreinformationaboutthemetrics.

LEEDsDA&ASEStudies(Annualsimulation)

21

Page 22: Insight Lighting Analysis Help

VisualresultsandscheduleresultswillpresentsDA300/50andASE1000/250results,sDAandASEAnnualHours,aswellascombinedmetricresults.

LEEDsDA&ASEStudies(Annualsimulation)

22

Page 23: Insight Lighting Analysis Help

NotethatsincethesDAandASEsimulationsmuchmorecomputationallyintensivethanasinglepointintimeanalysis,theCloudCreditcostsandtimewilllikelybegreaterthanforotheranalysistypes.TheDaylightAutonomy(sDAPreview)studytypewillanalyzeasamplingofthe3650hoursusedinthefullLEEDv4EQc7opt1(sDA+ASE)analysis.ThesDAPreviewstudytypewillrunfaster,andcostlessCloudCredits.ResultswillbeinlinewiththosefromthefullLEEDv4EQc7opt1(sDA+ASE)analysis.

LEEDsDA&ASEStudies(Annualsimulation)

23

Page 24: Insight Lighting Analysis Help

SolarAccessYoucanuseInsightLightingAnalysistostudysolaraccess,orhoursofdirectsunoveragivendaybyselectingtheSolarAccessstudytype.RequirementslikeSEPP65canbetestedandvalidatedusingtheSolarAccessworkflow.

Toconductthisstudies,followthestepsoutlinedintheOverviewandtakenoteofthefollowing.

SolarAccessstudiesareconductedforadayandselectedtimerange,withseveralcustomizablesettings.

SolarAccess

24

Page 25: Insight Lighting Analysis Help

A.Selectthedateandtimerangeforthestudy.Forallhoursselected,theDirectNormalIrradiance(DNI)andGlobalHorizontalIrradiance(GHI)willbesetto1000W/m2,andtheDiffuseHorizontalIrradiance(DHI)willbesetto1W/m2.SolarAccessautomaticallyusestheCIEClearSkymodel.

B.Settheminimumnumberofhoursthatwillberequiredtohavedirectsolaraccessandanalysisplaneheight.Inordertomeettheminimumthreshold,anypointintheroommustexceed4000lux.

Theresultssummarywillusethethresholdyouspecifiedtocalculatethepercentageofpassingroomsandproduceincontextresultsandacorrespondingschedule.

SolarAccess

25

Page 26: Insight Lighting Analysis Help

SolarAccess

26

Page 27: Insight Lighting Analysis Help

SolarAccess

27

Page 28: Insight Lighting Analysis Help

CustomIlluminanceStudies(Singlepointintime)SelectingIlluminanceAnalysisasthestudytypewillallowyoutocreateacustomizedsinglepointintimeanalysis.

Toconductthisstudies,followthestepsoutlinedintheOverviewandtakenoteofthefollowing.

IlluminanceAnalysisstudytypewillallowyoutoselectadate,time,acceptancethreshold,andanalysisplaneheight.

CustomIlluminanceStudies(Singlepointintime)

28

Page 29: Insight Lighting Analysis Help

A.Selecttwodifferentdateandtimesfortheanalysis.Customilluminanceanalysisstudytypeswillletyouanalyzetwodifferentscenariosforthecostofoneanalysis.

SelectaSkymodel,Date,andTime.Theweatherdatafortheselecteddateandtimewillautomaticallybefilledinbasedonwhatisavailableinthecorrespondingweatherfile.Ifyouwishtooverridethesevalues,uncheckUseWeatherData,andenteryourowndataforGlobalHorizontalIrradiance(GHI),DirectNormalIrradiance(DNI),andDiffuseHorizontalIrradiance(DHI).Whenusingtheweatherdatavalues,theskycoverpercentagewillbeshownfortheselecteddate/time.0%indicatesaclearsky.

B.SpecifylowerandupperThresholdvaluesandunits.Thesevalueswillbeusedtocalculatepass/failresultsandpopulatetheschedule.

TheAnalysisPlaneHeightdictateswheretheanalysisplanewillbeininchesabovetheRevitfloorelement.

Theresultssummarywillusethethresholdyouspecifiedtocalculatethepercentageofpassingroomsandproduceincontextresultsandacorrespondingschedule.

CustomIlluminanceStudies(Singlepointintime)

29

Page 30: Insight Lighting Analysis Help

CustomIlluminanceStudies(Singlepointintime)

30

Page 31: Insight Lighting Analysis Help

Toswitchbetweenthetwodatesandtimesthatweresimulated,selecttheanalysisplane,andchangetheAnalysisConfigurationinthePropertiespanel.

CustomIlluminanceStudies(Singlepointintime)

31

Page 32: Insight Lighting Analysis Help

CustomIlluminanceStudies(Singlepointintime)

32

Page 33: Insight Lighting Analysis Help

IncludingElectricLightsBydefault,allanalysistypesconsidernaturaldaylightfromthesunonly.However,ifyouwouldliketounderstandlightlevelconditionswhenelectriclightsareconsidered,youhavetheoptiontoincludethemaspartofthecustomilluminanceanalysisstudytype.

IfyouarenewtousinglightsinRevit,reviewtheresourcesavailablehere.

Toincludeelectriclightsinyoursimulations,you’llneedtomakesureyourmodelhaslightingfixturefamilies,andspecifically,associatedIESfiles.

InitiatetheLightingAnalysisplugin,andselectRunNewAnalysis.ClickonthesettingsiconinthetoprighttoaccesstheLightAnalysisSettings.

UncheckOverride“Lighting>Scheme”andpressSave.Whenthissettingischecked,RevitwilloverrideanyRenderingSettingsandincludeonlydaylightingfromthesun.Unchecked,thissettingallowsyoutochangetheRenderingSettingstoincludeelectriclights.

ClosetheLightingAnalysisintheClouddialogbox.

IncludingElectricLighting

33

Page 34: Insight Lighting Analysis Help

Openthe“_LightingAnalysisModelView”3DviewandselectRenderingSettingsfromthePropertiespanel.

ChangetheSchemetoinclude“Artificial”orelectriclights.

Schemesetting Outcome

Interior:Sunonly Onlydaylightfromthesunconsidered(defaultforalllightinganalysistypes)

Interior:SunandArtificial Daylightfromthesunandelectriclightsincluded

Interior:Artificialonly Onlyelectriclightsincluded

Onceyouhaveselectedanoptionthatincludeselectriclights,youcanselectArtificialLights…andcontrolwhichlightswillbeon(Dimming=1)andwhichlightswillbeoff(Dimming=0)fortheanalysis.

IncludingElectricLighting

34

Page 35: Insight Lighting Analysis Help

Afteryouhaveincludedelectriclights,andcontrolledwhichoneswillbeonoroff,initiatetheLightingAnalysispluginagain,andthistimesetthedate,timeandothersettingsandstarttheanalysis.

Afterreceivingyourresults,savetheproject.YoualsomightwanttoopentheLightAnalysisSettingsandcheckOverride“Lighting>Scheme”again.Thiswillmakesurethatallfutureanalysesonlyincludedaylightfromthesun.(ElectriclightswillbeincludedforfutureanalysesforallprojectsuntiltheOverride“Lighting>Scheme”ischeckedagain—thissettingpersistswithRevit,nottheproject.)

IncludingElectricLighting

35

Page 36: Insight Lighting Analysis Help

PerspectiveIlluminanceRenderingsInadditiontoincontextanalysisplanes,youcanalsorenderilluminancelevelsin3DperspectiveviewsfromRevit.ThestepsoutlinedbelowfollowadifferentprocessfromthestandardInsightLightingAnalysisworkflow,howevertheyusethesamesettingsandA360Renderingengine.

OpenabuildingelementmodelinRevit.AlsobesuretologintoyourA360account.LightinganalysisconsumesCloudCredits,soRevitwillneedtobeabletoaccessyourA360accounttocompletetheanalysis.

Fornewprojects,makesurethatyourlocationissetandaweatherfileisselected.

FromtheViewtab,selectRenderinCloud.

TheRenderinClouddialogwillappearwhereyoucancontrolyoursettingsandconfigurations.

PerspectiveIlluminanceRenderings

36

Page 37: Insight Lighting Analysis Help

A.Perspectiveilluminancerenderingsrequirea3DView.All3Dviewsavailableinyourprojectwillbepopulatedinthedropdown.Selectone,ormultiple,3Dviewsthatyouwishtorenderresultsfor.Notethatthedateandtimesettingsusedwillbeappliedtoall3Dviewsselected.

B.SettheOutputTypetoIlluminance.

C.SettheImageSizeandresolutionoftheoutputimage.ThiswillimpactCloudCreditcosts.

D.SelectanyDateandTime,oralternativelyselecttousesettingsfromthe3Dviewselected.

SelectaSkyModelfortheanalysis.Optionsinclude:

PerspectiveIlluminanceRenderings

37

Page 38: Insight Lighting Analysis Help

PerezAll-WeatherSkyCIEOvercastSkyCIEIntermediateSkyCIEClearSkyCIEUniformSkyDaylightFactorSky

EntertheappropriateDNIandDHIvaluesfortheanalysis.Thesevaluesdonotupdatewithyourlocationanddateandtimesettings.Itisnecessaryyoumanuallyenterthesevaluesinordertogetaccurateskyconditions.

SettheUnitsandLegendpreferences.Bydefault,alinearscaleisusedwith10proportionalsubdivisionsbasedontherangechosen.

E.PredictedCloudCreditusagewillupdateasthesettingsaremodified.SelectStartRenderingtobeginthesimulation.CloudCreditswillbechargedoncethiscommandisselected.

Whentherenderingsarecomplete,youwillreceiveanotificationinRevitaswellasanemailifyouselectedtoreceiveone.FromtheViewtab,selectRenderGallerytoaccessrenderings.

RenderingsintheRenderGalleryaresortedbyprojectnameanddatesubmitted.Locateyourproject,andclickontherenderingthumbnailstoenlargetheimages.

PerspectiveIlluminanceRenderings

38

Page 39: Insight Lighting Analysis Help

RenderingscanbedownloadedasJPGbyselectingthedropdownmenuofthethumbnailsorselectingActionsinthetopright.

Tochangeanyoftherenderingsettingsforaparticularview,selectRe-renderusingnewsettings.

Youwillnotbeabletochangethe3Dviewitself,butyoucanre-renderanexistingviewandmodifydatesandtimes,skymodels,orlegendscales.Tochangea3Dvieworanyofthematerialproperties,youwillneedtoinitiatetherenderingfromRevit.

PerspectiveIlluminanceRenderings

39

Page 40: Insight Lighting Analysis Help

ChangeanyofthesettingsandselectStartRendering.ThenewrenderingwillautomaticallyappearinyourRenderGallery.

TheRenderingSettingsforeach3Dviewanalyzedcontrolifelectriclightsareincludedintheanalysis.Toincludeelectriclights,openthe3DviewyouwillbesubmittingandaccessRenderingSettings.SettheSchemeaccordingtothedesiredoutcome.

PerspectiveIlluminanceRenderings

40

Page 41: Insight Lighting Analysis Help

PerspectiveIlluminanceRenderings

41

Page 42: Insight Lighting Analysis Help

ManagingResultsResultsareaccessedbyselectingacompletedanalysis,andpopulatingresultsinRevit.Fromthere,views,corresponding2Dfloorplans,andscheduleswillbeupdatedwithresults.

ManagingResults

42

Page 43: Insight Lighting Analysis Help

Accessing&SavingResultsWhenanalysisresultsarecomplete,youwillbepromptedtoaccepttheCloudCreditchargesandsavetheproject.Theresultswillthenbeaddedtothedropdownlistforselection.

Thedropdownmenuwilllistallavailableanalysisresults.Theanalysisdenotedwitha“*”identifiesthemostrecentsetofresultsthatwerepopulatedintheRevitmodel.Thisisimportanttoindicate,becauseitmeansthesearetheresultsthatarestoredwiththeRevitmodel.

WhenyousaveandclosetheRevitmodel,theresultswiththe“*”willbeaccessiblebythenextuserwhoopensthemodel;regardlessoftheiruseraccountID.AllotherresultswillonlybeaccessiblebytheuseraccountIDthatoriginallysubmittedthem.

Youcanchangewhichsetofresultsisaccessiblebyselectingadifferentsetofresultstogenerateinthemodel,thensavingtheRevitmodel.Youwillseethe“*”movetothelatestsetofresultsaccessed.

Inadditiontoaccessinganalysisresults,youcanalsomanageandexportanalysisresults.

Accessing&SavingResults

43

Page 44: Insight Lighting Analysis Help

A.TheAnalysisListManagerallowsyoutoDeleteorRenametheselectedanalysis.Renamingcanbehelpfulwhenyouhavemultipleanalysistypesyouaretryingtoorganize.Analysesyouhaverenamedwillappearabovethebreakinthedropdownlist.

B.Exportwillexportallthesettingsassociatedwiththeselectedanalysis.ItproducesanXMLfilethatincludesinformationsuchasdateandtimesettings,skyconditions,andlocation. 

Accessing&SavingResults

44

Page 45: Insight Lighting Analysis Help

AnalysisDisplaySettingsInsightLightingAnalysiswithRevitusesRevitFloorelementstoproduceanalysisplanes.

Formoststudytypes,multipleresultsareavailable.Tochangebetweenresults,selecttheanalysisplaneandchangetheAnalysisConfigurationinthePropertiespanel.

Youcanalsoturnanalysisplanesonandoffbylevelin3Dviews.Opena3DviewandselectAnalysisDisplaySettingsfromthePropertiespaneltoselectwhichanalysisplanesarevisibleintheview.

AnalysisDisplaySettings

45

Page 46: Insight Lighting Analysis Help

YoucanalsochangeresultUnitsthroughthisdialog.

AnalysisDisplaySettings

46

Page 47: Insight Lighting Analysis Help

CustomizingAnalysisVisualStylesForallanalysistypes,defaultanalysisdisplaystylesareusedtovisualizeresults.Thestepsbelowwillallowyoutomodifytheseorcreateyourown.

Openanyviewthathasvisibleanalysisresults.InthePropertiespanel,selectthe[…]forDefaultAnalysisDisplayStyle.

TheAnalysisDisplayStylesdialogwillappear.Thestylesontheleftarealldefaultstyles.Selectanyoneofthesetoseechangethevisualizationstyleinthecurrentview.

Tocreateyourownstyle,selectNew.

CustomizingAnalysisVisualStyles

47

Page 48: Insight Lighting Analysis Help

Forlightinganalysisresults,ColoredsurfaceandMarkerswithtextarethestylesthatshouldbeused.

ControltheSettings,Color,andLegendintherespectivetabs.

CustomizingAnalysisVisualStyles

48

Page 49: Insight Lighting Analysis Help

Addingvaluesassociatedwithspecificcolorswillallowyoutohighlightspecificthresholds.

CustomizingAnalysisVisualStyles

49

Page 50: Insight Lighting Analysis Help

RoomParametersWhenRoomsarespecifiedinthemodel,andalightinganalysisisrun,Roomparametersgetautomaticallycreated.Theseparametersareusedfortheschedulecalculations.Theseparametersareeditableinthe“_LightingAnalysisRoomSchedule”aswellaswhenaroomisselectedandthePropertiesareedited.

RoomParameters

50

Page 51: Insight Lighting Analysis Help

BestPractices1. GenerallywealwayssuggestrunningananalysisonasingleLevelwithacoarse

resolution(72-inchgrid)tomakesureeverythinglooksrightbeforedoingthewholebuilding.

2. RememberthatyoucanalwayschangeRoomssettingsafterananalysisiscomplete,withouttheneedtoreruntheanalysis.IfyouchangeRoomproperties(egIncludeInDaylighting,AutomatedShades),oraddorremoveRooms,justregeneratetheresultstoupdatetheschedulesandplanviews.RefertotheManagingResultssectionofthisguide.

3. The'_LightingAnalysisModelView'istheviewthatisexportedforanalysis.Checktobesurethateverythingyouwantincludedornotisinthatview.Youcan'HideInView'anyElementsthatyoudon'twanttoinclude.

4. IfyouhaveanyWorksetsthatarenotvisibleintheview,theseelementsmaystillbeincluded.Ifyouhavethatsituation,removetheworksetfromthemodelifyoudon'twanttoincludetheelements.

5. AllFloorelementsvisibleinthe'_LightingAnalysisModelView'willbeusedtogenerateanalysispoints(andthereforecloudcredits).IfyouareusingFloorobjectsforthingsthatarenotactualFloors(egshadingdevices),orifthereareFloorobjectsoutsidethebuilding,puttheseonaseparateLayersoyoucanexcludethoselayersfromtheanalysisrunandreducecreditcosts.

6. SinceFloorsareusedtogenerateanalysispoints,checkthatyourmodeldoesnothaveun-joinedlayeredfloors.Thisissometimesdonetohaveastructuralslab'floor'withdifferentfinish'floor'elementsontop.Inthosecasesyouwillgettwosetsofpoints,andthecostwillbehigher.Fortheseconditions,eitherHidethefinishFloororthestructuralFloor,JoinalltheassociatedFloorlayers,ifpossible,sotheyarerecognizedasasingleelementbytheLightingAnalysis,orputthestructuralFlooronaseparateLayertobeexcludedfromtheanalysisrun.

7. ChecktheMaterialsthatareInUseinthemodelforthefollowingconditions(alsorefertotheMaterialSettingssectionofthisguide):

8.AppearancePropertiesareusedforRenderInCloudandLAR,buttheGraphicsPropertiesarewhatyouseeinmostRevitVisualStyles.Reviewtheappearanceofthematerialsinthe'_LightingAnalysis'ModelViewbyeitherselectingthe'Realistic'visualstyle,orselectthecheckboxfor'UseRenderAppearance'forallmaterialsontheGraphicstaboftheMaterialeditor.Thelattermethodisbest,assometimespeopleuseaTransparencypropertyintheGraphicstabthatdoesn'tmatchtheoneintheAppearancetab.

BestPractices

51

Page 52: Insight Lighting Analysis Help

Checkthatnomaterialsareusing'SelfIllumination'intheAppearanceproperties.Thiswilladdartificiallighttothoseareasofthemodel.Checkwithyourrenderingteamwhendoingthat,asit'susuallyusedasaworkaroundtomakerenderingslookbetter.Checkthatnosignificantmaterials(egwalls,windows,etc)areusingaGenericAppearancepropertywith'Transparency'.Thiswillindeedmaketheobjecttransparent,butnotinaphysicallyaccurateway.It'sfinetouseforminormaterialslikefurniture,butnotforwindowsandotherprimaryelements.Instead,fortransparentelements,alwaysuseaGlassorGlazingmaterialwithRGBvaluescorrespondingtothetransparencyforthethicknessoftheelementthematerialisappliedto.YoucandownloadandusetheExceltool,"glass-Tvis-settings-inRevit_worksheet,"tohelpcalculatethat.(FYI,youcanaddthingslikefritpatternsusinganoverlaymaterialwithaCutoutpattern).IfmodifyingAppearanceproperties,rememberthatanyMaterialthatusesthesame'AppearanceAsset'willalsoinheritthosechanges.BestpracticeistoCopytheAppearanceAsset('DuplicatethisAsset'buttonintheupperrightoftheAppearancetab),soitisuniquebeforemodifyingitforanindividualMaterial.

BestPractices

52

Page 53: Insight Lighting Analysis Help

AdditionalSettings&ConsiderationsModelRequirementsViews&SchedulesMaterialSettingsLightAnalysisSettingsSkyModelsAnalysisCosts

AdditionalSettings&Considerations

53

Page 54: Insight Lighting Analysis Help

ModelRequirementsInsightLightingAnalysiswithRevitrequiresamodelcomposedofbuildingelements(walls,floors,roofs,windows,curtainwalls,etc).Aconceptualmassmodelwillnotwork.

FloorsFloorelementsarerequiredtoproduceanalysisplanes.Therefore,inorderforanalysisplanestobeproducedinamodel,floorsmustbepresent,andvisibleinthe“_LightingAnalysisModelView”3Dview.

RoomsRoomsarenotrequiredforallstudytypes,howevertheycanmakeparsingthroughresultseasierandproducedetailedschedules.Thisinformationcanbeaccessedinthe“_LightingAnalysisRoomSchedule.”

Additionally,Roomsarerequiredforthe2Dfloorplan“_LightingAnalysis”viewstobecreatedwhenresultsaregenerated.

Thefollowinganalysistypesrequireroomstobeplacedinamodeltogetsummaryresultsandschedules.Thisisbecausethecalculationsarebasedonroomarea.

LEEDv4EQc7opt1DaylightAutonomy(sDApreview)SolarAccess

AllotheranalysistypesdonotrequireRooms,butcanprovehelpfulwhenworkingwithresultsandschedules.WhentryingtorunoneoftheseanalysistypeswithoutRooms,youwillreceiveawarning,butcanproceedwiththeworkflow.

LinkedmodelsWhenworkingwithlinkedmodels,FloorsandRoomsmustbepartofthemainmodel.Allotherelementscanbelinkedin.TheanalysiswillnotrunifFloorsandRoomsarelinkedin.

ModelRequirements

54

Page 55: Insight Lighting Analysis Help

View&SchedulesTheInsightLightingAnalysispluginautomaticallycreatesseveralviewsandscheduleswhenananalysisisrun.Alloftheseareprefacedwith“_LightingAnalysis.”

Title Description

_LightingAnalysisModelView

3Dview;Thisistheviewthatdictateswhatisincluded(ornotincluded)inthelightinganalysisrendering;CanbeoverriddenusingLightAnalysisSettings

_LightingAnalysis–XXFloorPlan

2Dfloorplanviewcreatedforeverylevelthatisincludedintheanalysis,andhasRoomsspecified;IfalevelhasnoRooms,afloorplanviewwillnotbecreatedforit;CanvisualizewhichRoomsareincludedornotincludedinthisview

_LightingAnalysisFloorSchedule

Schedulecreatedshowingpercentageofareawithinresultsthresholds,bylevelincludedinanalysis

_LightingAnalysisRoomSchedule

Schedulecreatedshowingpercentageofareawithinresultsthresholds,bylevelincludedinanalysis

The"_LightingAnalysisModelView"3Dviewisusedtodefinethegeometryandsettingsforthelightinganalysis.Youcancreatespecialsettingsfortheanalysisbymakingthenecessarychangesinthis3DviewpropertiesbeforeclickingRunAnalysis.Forinstance,youcanhideorturnoffobjectsinthisviewifyouwishnotincludetheminthelightinganalysis.

Eachtimealightinganalysisisrun,itwillautomaticallychangesomeofthesettingsforthe"_LightingAnalysisModelView"3DviewunlessyouchangethesettingsdefinedintheLightAnalysisSettingsdialog.

Views&Schedules

55

Page 56: Insight Lighting Analysis Help

DesignOptionsWhenanalyzingandcomparingDesignOptionsmakesurewhateveroptionyouwanttoanalyzeisactiveinthe"_LightingAnalysisModelView"3Dview.Whatevergeometryisenabledinthisviewwillbeusedforthelightinganalysis.

DesignOptions

56

Page 57: Insight Lighting Analysis Help

MaterialSettingsTomakeyourresultsmoreaccurate,you’llwanttoassigntheappropriatematerialpropertiestoyourwindowglassandinteriorsurfaces.Ifyoufindthatyouoftenusesimilarmaterialfinishesorglazingpropertiesinyourprojects,itmightbeworthaddmaterialswithproperilluminancerenderingsettingstoyourMaterialBrowser.

MaterialSettings

57

Page 58: Insight Lighting Analysis Help

TransparentMaterialsVisibletransmittance(Tvis)fortransparentmaterialsisanimportantconsiderationforlightinganalysis.Itwilldictatehowmuchlightisableofenteringthebuildingthroughglazing.VisibletransmittanceiscontrolledbytheRGBvaluesintheRevitMaterialBrowser.Followthestepsbelowtosetvisibletransmittancefortransparentsurfaces.

ThedefaultvisibletransmittancesettingsformostglazingusedinRevitwindowfamiliesaregenerallymuchhigherthanglazingvaluestypicallyusedinbuildingstoday.SettingvalidglazingTvisisimportantforgettingvalidilluminancesimulationresults.

Selecttheglasspanethatyouwanttoedit.SelectEditTypefromthePropertiespanel.

ForWindowelements,thiscanbedonebyeditingthefamily.ForCurtainPanels,thiscanbedonebyselectingtheglazingelement.

Glasspanesthathaveathicknessof½”to1”(12.7mmto25.4mm)willprovidethemostaccuracyandflexibilityinrangeoftransparency.

Tochangethevisibletransmittancefortheglasspane,edittheMaterial.ThiswillopentheMaterialBrowser.

TransparentMaterials

58

Page 59: Insight Lighting Analysis Help

NotethattheAnalyticalPropertiesoftheglasswillnotaffectlightinganalysisresults.Thesesettingsareforenergyanalysisonly.

IntheMaterialBrowser,opentheAppearancetab.TheAppearancetabistheonlytabthataffectstheresultsforilluminanceanalyses.

Makesurethattheassetassignedtothematerialisanactualtransparentmaterial.Ifnot,replacetheassetusingtheAssetBrowserandassignatransparentmaterial,suchasGlazingorGlass.

TransparentMaterials

59

Page 60: Insight Lighting Analysis Help

TransparentMaterials

60

Page 61: Insight Lighting Analysis Help

Onceatransparentassethasbeenassignedtothematerial,undertheGlazingsection,changetheColortoCustom.Then,entertheRGBvaluescorrespondingtopanethicknessanddesiredTvis.

TransparentMaterials

61

Page 62: Insight Lighting Analysis Help

TheReflectancesettingisnotusedforilluminancerenderings.TheA360Renderingengineusesapredefinedreflectanceof~4%.

TheSheetsofGlassisalsonotusedforilluminancerenderings.TheA360RenderingengineusestheactualmodeledRevitgeometry.Forexample,ifaRevitwindowfamilyincludestwopanesofglass,theilluminancerenderingwillconsiderthecombinedeffectofbothpanels.

DiffuseglazingandtheeffectoflightpassingthroughfrostedorfrittedglassisnotsupportedbyRevit’smaterialandassetdefinitions.

TodeterminewhatRGBvaluestousetorepresentthedesiredTvisforyourglazing,usethetablebelow,ordownloadthisworksheet.DefiningthevisibletransmittancedependsnotonlyontheRGBvaluesused,butalsothethicknessoftheglassandhowmanypanesaremodeledinRevit.

ItisrecommendedtoalwaysuseRGBvaluesthatareequaltoeachother.Thisisforsimplicity’ssakeandshouldnotaffectanalyticalresultssinceilluminancerenderingsaremeasuringthequantityoflight,notthequalityorcolorofthatlight.

TransparentMaterials

62

Page 63: Insight Lighting Analysis Help

Tousethischart:

DeterminethemodeledthicknessoftheglazingpanegeometryinyourRevitmodelandthenumberofpanesmodeled.Formultiplepanes,thethicknessappliestoeachpane.Thesevaluesaretherows.DeterminetheoveralldesiredTvis.Thisvalueisthecolumn.

Forexample,foradoublepanewindowwhereeachpaneis3.0mmthick,andadesiredTvisof70%,theRGBvalueswouldbe50-50-50,andyouwouldenterR50-G50-B50intotheMaterialBrowser.Notethata“perfectlyclear”pieceofglasswouldhaveaTvisofabout92%.

TheactualTvisderivationforasinglepaneofglassiscalculatedas:

TransparentMaterials

63

Page 64: Insight Lighting Analysis Help

Tvis=0.9216*10^(thickness_in*log_10((color/255)^2))

Wherethickness_in=thicknessofthepaneininchescolor=valueintheRevitdialog[0-255]

Thetableabovecalculatestheinverseofthisfunction.Theequationisderivedfromthephysicsoflighttransportinglass.ItcombinestheBeer-LambertlawoftransmissionandtheFresnelequations(whichareusedtocalculatetheleadingconstant:1-R).Therendererimplementsthesephysicalequationsbecausetheyautomaticallyaccountforthingslikedirectionalvariationinreflectivityandtransmissivityandgreaterabsorptioninthickerpanesofglass.Furtheritensuresthatglassisalwayshandledinaphysicallycorrectandconsistentmanner.

TransparentMaterials

64

Page 65: Insight Lighting Analysis Help

OpaqueMaterialsMaterialreflectivityisanimportantconsiderationforlightinganalysis.Itwilldictatehowmuchlightbouncesofftheinteriorsurfacesandfurtherintothebuilding.MaterialreflectivityiscontrolledbytheRGBvaluesintheRevitMaterialBrowser.Followthestepsbelowtosetmaterialreflectivityforopaquesurfaces.

Standardvaluesformaterialreflectivityarelistedbelow.

Element Reflectivity

Ceilings 85%

Walls 60%

Floors 25%

DownloadthisworksheettohelpquicklydefineRGBvaluesfordifferentreflectivityvalues.

SelecttheRevitelementthatyouwanttoedit.SelectEditTypefromthePropertiespanel.

Tochangethepropertiesassociatedwiththematerialsthatmakeuptheelement,EdittheStructure.

OpaqueMaterials

65

Page 66: Insight Lighting Analysis Help

Selecttheinteriorfaceoftheelement.ThiswillopentheMaterialBrowser.

OpaqueMaterials

66

Page 67: Insight Lighting Analysis Help

IntheMaterialBrowser,opentheAppearancetab.TheAppearancetabistheonlytabthataffectstheresultsforilluminanceanalyses.

IntheGenericpanel,editingtheRGBvalueswillcontrolreflectivityforopaquefinishes.IfanimageisselectedfortheAppearance,theaveragecolorsofthepicturewilldeterminethebasicmaterialreflectivity.

OpaqueMaterials

67

Page 68: Insight Lighting Analysis Help

RGBvaluesarebasedonthefollowingformula:

$$(0.2126R+0.7152G+0.0722B)/255

$$

Youcanusethetablebelow,ortheworksheetavailableheretodefineRGBvaluesforspecificreflectivityvalues.

OpaqueMaterials

68

Page 69: Insight Lighting Analysis Help

WhenallotherattributesintheAppearancetabareunchecked,thematerialwillhaveamattefinishandonlydiffusereflectivity(itwillnotbe“shiny”).Youcansimulateshiny,orspecular,materialsbycheckingReflectivityandchangingthesettings.

OpaqueMaterials

69

Page 70: Insight Lighting Analysis Help

AllothercategoriesintheAppearancetab(Transparency,Cutouts,SelfIllumination,Bump,andTint)definesurfaceappearanceproperties.Thesewillaffectoveralllightreflectivity.

OpaqueMaterials

70

Page 71: Insight Lighting Analysis Help

LightAnalysisSettingsFormostanalysistypes,itisnotnecessarytochangeanyofthedefaultlightanalysissettings,howeversomeofthemcanhelpyouworkmoreefficiently.Theimagebelowdepictsthedefaultsettings.

ThesesettingspersistwithRevit,nottheproject,sobeawarethatanychangesthatyoumaketothesettingswillkeepforallotherprojectsuntilyouchangethesettings.

Troubleshooting

LogdebugfileinC:\Autodesk\RevitDaylighting

Thisoptionautomaticallycreatesalogfileinthelistedstructure.Thiscanbehelpfulwhentroubleshooting.

DisableLARinworkshareddocuments

LightingAnalysissavesdatafromthelastanalysisgeneratedwiththeRevitdocument.Selectthisoptiontopreventrunningalightinganalysisonaworksharedmodel.

RenderingSettingsfor_LightingAnalysisModelView

LightAnalysisSettings

71

Page 72: Insight Lighting Analysis Help

The"_LightingAnalysisModelView"3Dviewisusedtodefinethegeometryandsettingsforthelightinganalysis.AnychangesyoumaketothisviewbeforeselectingRunAnalysiswillberepresentedinyouranalysisresults.Forinstance,youcanhideorturnoffobjectsinthisviewtonotincludetheminthelightinganalysis.

Eachtimealightinganalysisisrun,itwillautomaticallychangesomeofthesettingsforthe"_LightingAnalysisModelView"3Dview,unlessyouchangethesettingsdefinedintheLightAnalysisSettingsmenu.

Override“Lighting>Scheme”

Ifchecked,theLightingSchemefortheRenderingSettingsforthe"_LightingAnalysisModelView"3Dviewissetto"Interior:Sunonly".Unchecked,thissettingallowsyoutochangetheRenderingSettingstoincludeelectriclights.

Override“Background>Style”

Ifchecked,theBackgroundStylefortheRenderingSettingsforthe"_LightingAnalysisModelView"3Dviewissetto"Sky:Noclouds".

Turnoff“SectionBox”

Ifchecked,thesectionboxforthe"_LightingAnalysisModelView"3Dviewisturnedoff.Uncheckedthissettingallowsyoutoexcludepartsofthemodelusingthesectionbox,butbeawareanyopenareasorfloorswillbesubjectedto“fullsun.”

Turnoffvisibilityfornon-permanentmodelcategories

Thisoptionhidesthefollowingcategoriesofelementsinthe"_LightingAnalysisModelView"3Dview:Furniture,FurnitureSystems,Entourage,_andPlanting_.Uncheckingthissettingallowsyoutoincludetheseelementsandtheirimpactwillberepresentedinthelightinganalysisresults.

SetPhaseFilterto“Complete”

Ifchecked,thePhaseFilterforthe"_LightingAnalysisModelView"3Dviewwillbesetto"ShowCompleteforLighting".ThisPhaseFilterwilldisplayelementsinNewandExistingphases"ByCategory"andelementsinTemporaryandDemolishedphaseswillnotbedisplayed.

Override“ViewTemplate”

Ifchecked,theViewTemplateforthe"_LightingAnalysisModelView"3Dviewwillbesetto"None."

Resultsassistant

Trackmodelchanges

Checkthisoptiontobewarnedwhenachangeismadetothemodelthatinvalidatesthelightinganalysisresults.

Exportrawanalysisdata(caution:largefiles)

UsethisoptionopensanExcelwindowwithanalysispointsandilluminancevalueswhenresultsaregenerated.Thisexportoptionisonlyavailableforthefollowingstudytypes:IlluminanceAnalysis,LEED2009IEQc8opt1,LEEDv4EQc7opt2

LightAnalysisSettings

72

Page 73: Insight Lighting Analysis Help

LightAnalysisSettings

73

Page 74: Insight Lighting Analysis Help

SkymodelsCustomizedIlluminanceAnalysisandPerspectiveIlluminanceRenderingsallowyoutospecifySkyModelsandirradiancedata.

PerezAll-WeatherSky

ThemostcommonlyusedmodelindaylightingsimulationapplicationsandthemodelmostanalystsuseinRadiance.ThePerezmodelyieldsaccurateresultsforallskytypesfromcleartofullyovercast.ItisalsothemodelLEEDrequiresbeusedfordaylightingpredictions.

CIE:OvercastSky,IntermediateSky,ClearSky,UniformSky

SimplifiedandstandardizedinstancesofthePerezmodel.Theyprovidestandardconditionsfordaylightingapplications.Ifyouknowwhatkindofskyyouwillhave,oryou'retryingtogetvaluesforaparticularsituation(clearorovercast)thenitisagoodideatouseaCIEmodel.

DaylightFactorSky

Percentageofnaturallightfallingonsurfacescomparedtothatwhichwouldhavefallenonacompletelyunobstructedhorizontalsurfaceundersameskyconditions.ThelocationortimeofdaydoesnotmatterifyouareusingaDaylightFactorSky.Resultswillbeexpressedasapercentage.

Ifyouareunsureofwhichskymodeltouse,agoodplacetostartiswiththeCIEOvercastSkymodel.Thismodelwillnothavetheuniquecharacteristicsofdirectsun,andrepresentsanovercastconditionthatcouldhappenatanytimeofdayandisagoodwaytoputyourdesigntothetest.ItisoftenstandardpracticetoalsorenderusingthePerezmodelatanequinoxandthesolsticestovisualizearangeofstandardconditions.

SkyModels

74

Page 75: Insight Lighting Analysis Help

AnalysisCostsInsightLightingAnalysiswithRevitanalysisusesCloudCreditsassociatedwithyourA360account.LearnmoreaboutCloudCredits.

YouwillbenotifiedhowmanyCloudCreditsarerequiredandhowmanyyouhaveavailablewitheachanalysis.Whenchangingstudytype,levelsincludedintheanalysis,orresolutionsettings,selectingCheckPricewillrecalculateyourCloudCreditcosts.YouwillnotbechargedanyCloudCreditsuntiltheanalysissuccessfullycompletesandyougenerateanalysisresultsinyourmodel.Youwillhavetheoptiontoacceptordeclinethetransactionatthispoint.

AnalysisCosts

75

Page 76: Insight Lighting Analysis Help

AnalysisCosts

76

Page 77: Insight Lighting Analysis Help

CloudCreditPricing

CloudCreditPricing

77

Page 78: Insight Lighting Analysis Help

ManageCloudCreditCostsTheareaoffloorobjectsincludedintheanalysisdeterminesCloudCreditcosts.KeepCloudCreditcostsdownbyconsideringthefollowing:

Chooseonlythefloorsyouareinterestedin.

Sometimesfloorobjectscanbeusedtobuildexteriorsurfaces,shadingdevices,etc.Analyzeonlyspecificlevelsorremoveunwantedfloorareafromthe3D“_LightingAnalysisModelView.”Also,makesuretherearenotduplicatefloorsoverlappingonthesamelevel.

Chooseonelevelatatimetoconfirmmodelsettingsbeforerunningafullanalysis.

Ifyourlevel'sfloorareaiswithinthefreepricingthreshold,youcanoftenrunthesesetupanalysesforfree.Usethesefreeanalysestogetfamiliarwithhowthetoolworksandtestdifferentsettingbeforerunningananalysisforthefullmodel.

Chooselowresolution(72inch)toconfirmmodelsettingsbeforerunningahighresolution(12inch)analysis.

Usealowresolutionanalysistocheckyoursettingsandmaterialsandgetfamiliarwiththetool.Lowresolutionanalysesareavailableforsomestudytypes,andrequirelessCloudCredits.Whenreadyforfinalanalysis,youcanuseahighresolution.

Onlyrunanewanalysiswhenyoumakeaninvalidatingchange.

Onceyoupopulateanalysisresultsinyourmodel,youcandoalotwithouthavingtorunanewanalysis.IfyoumodifyRooms,RoomParametersettings,analysisdisplaystyles,schedulelayoutandcolumncontents,ormodifyorcreatenew3Dviews,justselecttheruntorepopulateandupdateresults.Whenyouchangethemodelgeometry,materials,orlightfixtures,thenyoushouldrunanewanalysis,asthelightingconditionsarechanged.

Joinfinishfloorstounderlyingfloorlayersonthesamelevelsoonlyonelayerisanalyzed.

ManyRevitmodelsincludelayersoffloorstoindicatedifferentfinishsurfacesindifferentareasofthebuilding.Thisresultsinincreasedfloorarea,andincreasedCloudCreditcosts.BestpracticeistouseModify>Geometry>Jointojointhelayers.Youwillstillbeabletoshoworhidefinishfloorsindifferentviews,butiffloorsarejoined,onlythetoplevelwillbeusedfortheanalysis.

ManageCloudCreditCosts

78

Page 79: Insight Lighting Analysis Help

ManageCloudCreditCosts

79

Page 80: Insight Lighting Analysis Help

ValidationInsightLightingAnalysiswithRevitleveragestheA360Renderingservice.

A360Renderingusesbidirectionalraytracingbutwithanadditionalintelligentalgorithmtodeterminetherayordersuchthatthemostimportantraysaregeneratedfirst.Theresultisamuchfasterconvergencetofinalresults.Theenginecalculatesallthebouncesthatareimportantformakingconclusions.ThealgorithmiscalledMultidimensionalLightcuts(Siggraph2006),withtradesecret/patentedextensions.Thisapproachdiffersfromothertoolsthatfollowthebouncesofaphotonevenpastthepointwhereitpracticallyaffectstherendering.

Theenginehasbeenvalidatedwiththehelpofoneofthetopdaylightingfirmsinthecountry.TheyusedaconsistentmodeltocompareA360RenderingilluminanceoutputstobothRadianceandtoactuallightlevelmeasurementsofthespace.

Validation

80

Page 81: Insight Lighting Analysis Help

Support&FAQGetsupportforInsightLightingAnalysiswithRevitontheInsightLighting&SolarAnalysisForums.

BesuretovisittheA360RenderingForumifyouhavespecificquestionsaboutA360Rendering.

Support&FAQ

81

Page 82: Insight Lighting Analysis Help

TroubleshootingAllmyresultsarezero(red)—thiscan’tberight.

Thisisoftenthecasewhentransparentassetsaren’tactuallyassignedtoglazingmaterials.Theglassinyourmodelmaylooktransparent,butyouneedtomakesurethematerialassetassignedtoitistransparentaswell.FollowthestepsfordefiningTransparentMaterials,andpayspecialattentiontoassigningatransparentAsset.Usingclearglazingisagoodoption.

Ifyou’reconfidentthatmaterialsareproperlysetup,makesuretherearenoopaqueelementsblockingyourwindows.Forexample,sometimeswhenusinglayeredwallconstructions,awindowelementwon’tcreateavoidforallwalllayers.Ifthereisawalllayer,oranyotherelement,blockingthewindows,makesuretohideitinthe“_LightingAnalysisModelView.”

ChecktheRenderingSettingsforyourviewandmakesuretheyareincludingthedaylightorelectriclightinputs.AlsocheckyourLightAnalysisSettingstomakesuretheysupportyourinputconditions.

Finally,checktomakesurethatyoursimulationdateandtimeisoccurringatanappropriatetime.Ifyouareanalyzingdaylightvaluesat12AM(midnight),therewon’tbeanydaylighttosimulate(unlessofcourseyouareinanextremenorthernorsouthernlatitude!).

Idon’tthinkmyresultsmakesense.

Ifyourresultsdon’tseemright,besuretocheckthesuggestionslistedaboveformaterialsettings,glazingobstructions,settings,andsimulationtime.Additionally,youmightwanttocheckthefollowing.

Opaquematerials(walls,floors,ceilings,etc)mayhavea"self-illuminance"modifierdefinedintheAppearancetaboftheMaterialBrowser.Thiscanhappenartificialcharacteristicsareusedtoenhancevisualrenderings.

Inthe“_LightingAnalysisModelView,”makesurethereisnotSectionBoxcuttingawallopen,oranyotherpartofyourmodel.TheSectionBoxisusuallyautomaticallyignoredforanalysis,buttheLightAnalysisSettingsoptionmayhavebeenchanged.

I’mseeingconflictingresultsplanesbetweenmy2Dand3Dviews.

ItmightbepossiblethattherearetwodifferentFloorelementssandwichedtogetherinyourmodel.SincethelightinganalysisplanesarecreatedfromFloorelementsiftherearemultipleFloorelementsontopofeachotherorassignedtothesameLevel,therewilllikely

Troubleshooting

82

Page 83: Insight Lighting Analysis Help

bemultipleanalysisplanesontopofeachother,creatingconflictingviewsordoublemarkers.Tryremovingorhidingtheunnecessaryfloorsinthe"_LightingAnalysisModelView."Bonus,doingsowillprobablyloweryourCloudCreditcostsaswell.

CanIexcludeRoomsfromthecalculationbeforeIsubmittheanalysis?

Roomsthatarecheckedincheckedoruncheckedinthe“_LightingAnalysisRoomSchedule”willonlyimpactresultsvisualizationsandthresholdcalculations.Itwillnotimpactfuturesanalyses.

Toexcludeareasorelementsfromfuturelightinganalyses,youwillwanttocontrolthe"_LightingAnalysisModelView."

HowdoIincludetheimpactsofSola-tubesinmyanalysisresults?

Tubularskylights(SolaTube,VeluxSunTunnel,ODL,etc)canbemodeledasLightFixturesassociatedwithanIESlightingdistributionprofile.TheIESfilesshouldbespecifictolocationandtimeofyouranalysisandareavailablefrommostskylightmanufacturers.MostmanufacturersalsohaveRevitfamiliesthatcanbeusedtohosttheIESfile,oryoucanuseanygenericfixturetocreateatubularskylightfixture.

Aftercreatingthefixture,followtheworkflowtoincludeelectriclights,wheretheskylightfixturesareactingaselectriclights.

Whyaren’tAutomatedShadesavailableforsDA/ASEstudytypes?

OneofthedifferencesbetweenLEEDv4EQc7opt1(sDA/ASE)calculationsandLEEDv4EQc7opt2(singlepointintime)calculations,isthatforsDA/ASEanalysistypes,shadesneedtophysicallymodeled,versusjustexpandingthethresholdlimits.Currently,Revitdoesn’tincludeshadesforsDA/ASEanalysistypes.However,it’sworthnotingthatincludingshadesshouldchangetheresultsbyagreatamount.Infact,includingautomatedshadeswon’treducethedirectsun(ASE)liability,asASEhastobecalculatedwithshadesopen.

MyavailableCloudCreditsaren’tright.

IfyouravailableCloudCreditsdon’tmatchupwithwhatislistedasavailableinmanage.autodesk.com,youmayneedtocontactyourAutodeskresellerorsubmitasupportrequest.

WhatinformationgetssenttotheA360RenderingenginefrommyRevitmodel?

RevitcreatesanSPDfilethatgetssenttotheA360Renderingengine.TheSPDcontains:

Modelgeometry(astrianglemeshes)Projectlocation(representedbytheassociatedweatherfile)Materialdefinitionsandtextureimages(ifincluded)

Troubleshooting

83

Page 84: Insight Lighting Analysis Help

LightfixturedefinitionsandassociatedIESfilesDateandtimesetfortheanalysisNamesandpositionsofselected3Dviewcameras

Troubleshooting

84