INNOVATION FOR ANY PEX CONNECTION
Transcript of INNOVATION FOR ANY PEX CONNECTION
WARNING: Cancer and ReproductiveHarm - www.P65Warnings.ca.gov
WEBSTONE EXCLUSIVESNOW FOR F1807 & F1960 PEX
F1807 CRIMP OR CLAMP
F1960 COLD EXPANSION
INNOVATION FOR ANY PEX
CONNECTION
CONDITIONS APPLY. SEE WEBSTONEVALVES.COM FOR FULL DETAILS.
webstonevalves.com/pro-pal
VALVE INNOVATION GUARANTEED FOR LIFE
• Isolate & drain any portion of a piped system
• Eliminates multiple fittings
• Reduces leak paths
• Saves labor & space
• Avoids reduced-port alternatives
• Creates cleaner-looking, more efficient installations
• Also available in FIP, SWT, Press and Push on select models
WARNING: Cancer and ReproductiveHarm - www.P65Warnings.ca.gov
LEAD-FREE: Weighted average lead content ≤ 0.25%
Pro-Pal® is a registered trademark of NIBCO INC. ©2019 NIBCO INC., All Rights Reserved. FORM#: PEXPP-0819
PRO-PAL BALL DRAINFull Port Forged DZR Brass Ball Valve w/ Hi-Flow Hose Drain, Reversible Handle & Adjustable Packing Glands
LEAD-FREE BRASS
Certified to NSF/ANSI 61 & 372 NSF/ANSI 14
SIZE ITEM # CTN/CASE CASE WTASTM F1807 PEX 400 PSI CWP Max/200ºF Max1/2" H-10612W 4/40 343/4" H-10613W 4/32 351" H-10614W 2/20 311 1/4" H-10615W 2/16 371 1/2" H-10616W 1/8 262" H-10617W 1/6 30ASTM F1960 PEX 400 PSI CWP Max/200ºF Max1/2" H-30612W 4/40 353/4" H-30613W 4/32 371" H-30614W 2/20 321 1/4" H-30615W 2/16 401 1/2" H-30616W 1/8 282" H-30617W 1/6 33
PRO-PAL UNION BALL DRAINFull Port Forged DZR Brass Ball Valve w/ Single Union End, Hi-Flow Hose Drain, Reversible Handle & Adjustable Packing Glands
LEAD-FREE BRASS
Certified to NSF/ANSI 61 & 372 NSF/ANSI 14
SIZE ITEM # CTN/CASE CASE WTFIP Union × ASTM F1807 PEX 250 PSI CWP Max/200ºF Max1/2" H-10432W 4/16 223/4" H-10433W 4/16 271" H-10434W 2/16 351 1/4" H-10435W 2/8 261 1/2" H-10436W 1/8 382" H-10437W 1/4 28FIP Union × ASTM F1960 PEX 250 PSI CWP Max/200ºF Max1/2" H-30432W 4/16 223/4" H-30433W 4/16 271" H-30434W 2/16 361 1/4" H-30435W 2/8 271 1/2" H-30436W 1/8 392" H-30437W 1/4 29
PRO-PAL UNION BALLFull Port Forged DZR Brass Ball Valve w/ Single Union End & Adjustable Packing Gland
LEAD-FREE BRASS
Certified to NSF/ANSI 61 & 372 NSF/ANSI 14
SIZE ITEM # CTN/CASE CASE WTFIP Union × ASTM F1807 PEX 250 PSI CWP Max/200ºF Max1/2" H-10422W 5/40 333/4" H-10423W 4/32 401" H-10424W 4/20 36FIP Union × ASTM F1960 PEX 250 PSI CWP Max/200ºF Max1/2" H-30422W 5/40 333/4" H-30423W 4/32 401" H-30424W 4/20 36FIP Union × FIP 250 PSI CWP Max/200ºF Max1/2" H-40422W 5/40 353/4" H-40423W 4/32 411" H-40424W 4/20 37FIP Union × SWT 250 PSI CWP Max/200ºF Max1/2" H-50422W 5/40 333/4" H-50423W 4/32 401" H-50424W 4/20 36FIP Union × Push 200 PSI CWP Max/200ºF Max1/2" H-60422W 5/40 343/4" H-60423W 4/32 381" H-60424W 4/20 38FIP Union × Press 250 PSI CWP Max/200ºF Max1/2" H-80422W 5/40 373/4" H-80423W 4/32 431" H-80424W 4/20 34
Also available with FIP, SWT, SWT × FIP, Press, Press × FIP,
Press × PEX, PP-R and PP-RCT connections
Also available with FIP, SWT and Press connections
STEP SAVING VALVESFOR THE PROFESSIONAL
• Eliminate assemblies needed to isolate & drain any portion of a piped system
• Reversible handle for added versatility
• Exclusive adjustable flow path allows for draining from either side of the ball
DRAINING FROM BELOW BALL
System PurgingNormal Operation
DRAINING FROM ABOVE BALL
System PurgingNormal Operation
Adjustable stem directs flow into the hi-flow hose drain from either side of the ball
T-Flow Ball
ADJUSTABLE
ADJUSTABLE
ADJUSTABLEWinterize an
entire building with simple quarter-turn
actions
• All the features of the ball drain, with integrated union connection
WEBSTONE EXCLUSIVES NOW FOR F1807 & F1960 PEX
Ideal for tanked and next-gen tankless water
heater connections
THE OLD WAY
THE WEBSTONE WAYREPLACES
3COMPONENTS
SAVES
18MINUTES
ELIMINATES
2LEAK PATHS
THE OLD WAY
THE WEBSTONE WAY
Draining from Below Ball
Draining from Above Ball
REPLACES
6COMPONENTS
SAVES
45MINUTES
ELIMINATES
5LEAK PATHS
Draining from Below Ball
Draining from Above Ball
THE OLD WAY
THE WEBSTONE WAYREPLACES
4COMPONENTS
SAVES
27MINUTES
ELIMINATES
3LEAK PATHS
METERMETER
• Easily disconnect and replace any portion of a piped system
NEW
A L S O A V A I L A B L E