Injection System VMU plus - MKT Metall-Kunststoff-Technik€¦ · The injection system VMU plus is...
Transcript of Injection System VMU plus - MKT Metall-Kunststoff-Technik€¦ · The injection system VMU plus is...
104... a solid connection
Injection System for cracked concrete, non-cracked concrete and brickwork
Injection System VMU plus
Cartridge VMU plus 410Coaxial cartridgeContent: 410ml
Cartridge VMU plus 345Side-by-side cartridgeContent: 345ml
Cartridge VMU plus 300Foil tube cartridgesuitable for silicone gunsContent: 300 ml
Cartridge VMU plus 280Coaxial cartridgesuitable for silicone gunsContent: 280ml, including 2 mixers, attached to the cartridge
Range of loading: 0,3 kN – 202,0 kNConcrete quality: C20/25 - C50/60Brickwork: Solid and perforated brickMaterial: Steel zinc plated, hot dip galvanized, Stainless steel A4/316, Stainless steel HCR
DescriptionThe injection system VMU plus is a universal injection system for almost all applications and materials. Besides the use in non-cracked concrete and masonry, VMU plus is also approved for �xings in crak-ked concrete and for post installed rebar connections1). The new Euro-pean Technical Assessment ETA-13/0909 includes 6 sizes of perforated sleeves up to 200 mm length and is approved in 15 di�erent types of bricks. To complete the fastening, various anchor rods or internal sleeves can be used from the existing MKT-range (VMU-A, VMU-IG, VM-A and V-A), as well as standard threaded rods or reinforcing bars. In perforated brick, a perfo sleeve is required.
Advantages- Only one adhesive for almost all applications, more �exibility, less inventory, greater application safety- Approved for cracked and non-cracked concrete - Approved for post-installed rebar connections (Ø8-Ø32)1)
- Approved application in wet or water-�lled drill holes (M8-M16)- Approved for autoclaved aerated concrete, solid and perforated
brickwork- Approved with standard threaded studs (test certi�cate required)- Base material temperature during installation -10°C (concrete) to +40°C- Ambient temperature when completely cured -40°C to +120°C (concrete)- Variable anchorage depth for less drilling e�orts- Fire test report- Opened cartridges can be re-used with a new mixer nozzle- Styrene-free vinylester resin- Approved for use under seismic action according to the perfor-
mance category C1
Cartridge VMU plus 150Coaxial cartridgesuitable for silicone gunsContent: 150ml
CartridgeVMU Coaxial cartridgesuitable for silicone guns
CartridgeVMU Coaxial cartridgeContent:
1)only with Coaxial- and Side-by-side VMU plus cartridge
Threaded Stud VMU-Afor concrete and brickwork
Perfo Sleeve VM-SHfor perforated brick
Threaded Stud VM-A 1 meter length, to be cut to the required lengthfor concrete and brickwork
Perfo Sleeve VM-SHfor perforated brick
Internally Threaded Sleeve VMU-IGfor concrete and brickwork
Threaded Stud V-Afor concrete and brickwork
C1F30-F120
Fire testedCertified to
NSF/ANSI 61
ESR - 4004
2019 PR MKT
105 ... a solid connection
Ch
emic
al A
nch
ors
Chemical Anchors
Additional advantages VMU plus Polar- Fast and reliable curing even at low temperatures and minus de-
grees- Approved for cracked and non-cracked concrete as well as masonry
even at icy -20 ° C - Approved temperature range from + 10 ° C to -20 ° C for base mate-
rial and cartridge. Heating and keeping the cartridge warm before installation is not necessary.
- The same European Technical Assessments (ETA-11/0415 and ETA-13/0909) for VMU plus and VMU plus Polar; therefore the Installation is possible from + 40 ° C to -20 ° C temperature without recalculation of the application.
Ch
emic
al A
nch
ors
Cartridge VMU plus 825Side-by-side cartridgeContent: 825 mlWith big mixer VM-XL and reducer / extension tube for drill holes down to 12mm diameter
Cartridge VMUSide-by-side cartridgeContent: 825 mlWith big mixer VM-XL and reducer / extension tube for drill holes down to 12mm diameter
Cartridge VMU plus 420 PolarCoaxial cartridgeContent: 420ml
Cartridge VMU plus 345 PolarSide-by-side cartridgeContent:345ml
CartridgeVMU Side-by-side cartridgeContent:
Cartridge VMU plus 300 PolarFoil tube cartridgesuitable for silicone gunsContent:300 ml
Applications
Fastenings in cracked and non-cracked concrete:Base plates, supports, mounting of joint tapes, shelves, brackets,railings, facade substructures, wooden structures, cable trays, etc.
Fastenings with rebars in cracked and non-cracked concrete - withshear forces:Shear connectors, wall connecting reinforcement, concrete overlay
Post-installed rebar connections1):Ceiling and wall connections, structural reinforcement, structuralcomplement building extensions, connection of balconies andcanopies, subsequent attaching of „forgotten or misplaced“ reinforcing bars
Fastenings in Brickwork: Canopies, door and window frames, facade substructures, battens,gates etc.
1)only with Coaxial- and Side-by-side VMU plus cartridge
2019 PR MKT
106... a solid connection
Injection System for cracked concrete, non-cracked concrete and brickwork
One static mixer VM-X as well as one screw-on cap comes with each cartridge. (VMU plus 825: VM-XL). Usable length of static mixer see below, Extension tubes see page 110.1)Cartridge VMU plus 280 comes with 2 mixers.2)With larger cross section for larger drill holes or post-installed rebar connections.
Description Ref. No. Con-tentml
Cont. of master box
pcs
Weight per master box
kg
Weight per piece
kg
Cartridge VMU plus 150 28255271 150 12 4,20 0,34
Cartridge VMU plus 2801) 28252401 280 12 6,70 0,56
Cartridge VMU plus 300 28255126 300 12 6,40 0,53
Cartridge VMU plus 300 Polar 28252901 300 12 6,40 0,53
Cartridge VMU plus 345 28254001 345 12 8,00 0,65
Cartridge VMU plus 345 Polar 28253901 345 12 8,00 0,65
Cartridge VMU plus 410 28256041 410 12 10,1 0,83
Cartridge VMU plus 420 Polar 28257121 420 12 10,1 0,83
Cartridge VMU plus 825 28259001 825 8 13,0 1,63
Static mixer VM-X 28305111 - 12 0,12 0,01
Static mixer VM-XL2) 28305201 - 10 0,28 0,03
Mixer extension VM-XE 10/200 (200mm) 28306011 - 12 - 0,01
Mixer extensiong VM-XE 10/500 (500mm) 85951101 - 10 0,02 0,02
Injection Cartridge VMU plusTwo component cartridge, styrene-free
Approved for non-cracked concrete and brickwork
Storage Box In stackable multi-purpose container
Storage box, the container for various items
Dimensions storage box
Description Ref. No. Contents Quantity
pcs.
Weight per Box
kg
Storage box VMU plus 280 28999148 Cartridge VMU plus 280 20 12,8Static mixer VM-X 40
Storage box VMU plus 300 28999661 Cartridge VMU plus 300 Polar 20 12,8Polar Static mixer VM-X 40Storage box VMU plus 345 28999640 Cartridge VMU plus 345 20 15,3
Static mixer VM-X 40Storage box VMU plus 345 28999670 Cartridge VMU plus 345 Polar 20 15,3Polar Static mixer VM-X 40Storage box VMU plus 410 28999652 Cartridge VMU plus 410 20 18,0
Static mixer VM-X 40
Description Heightmm
Widthmm
Depthmm
Storage box 220 400 300
Curing Time Injection Adhesive VMU plusTemperature in drill hole
Cartridge temperature1)
Max. Gel time Curing timeDry base material
Wet base material
-10°C – -6°C +15°C – +40°C 90 min 24 h 48 h
-5°C – -1°C
+5°C – +40°C (+25°C)2)
90 min 14 h 28 h
0°C – +4°C 45 min 7 h 14 h
+5°C – +9°C 25 min 2 h 4 h
+10°C – +19°C 15 min 80 min 160 min
+20°C – +24°C 6 min 45 min 90 min
+25°C – +29°C 6 min (4 min)2) 45 min (25 min)2) 90 min (50 min)2)
+30°C – +34°C +5°C – +40°C
(< +20°C)2)
4 min (2,5 min)2)) 25 min (15 min)2) 50 min (30 min)2)
+35°C – +39°C 2 min (2,5 min)2) 20 min (15 min)2) 40 min (30 min)2)
+40°C 1,5 min (2,5 min)2) 15 min 30 min1)When installing 2)Values in brackets for rebar connections (ETA-11/0514)
Cartridge temperature during installing -20°C to + 10°C
Curing Time Injection Adhesive VMU plus Polar
Temperature (°C) of the base material
Gel time Curing time
dry base material wet base material
-20°C to -16°C 75 min 24 h 48 h
-15°C to -11°C 55 min 16 h 32 h
-10°C to -6°C 35 min 10 h 20 h
-5°C to -1°C 20 min 5 h 10 h
0°C to +4°C 10 min 2,5 h 5 h
+5°C to +9°C 6 min 80 min 160 min
+10°C 6 min 60 min 120 min
Usable length Static mixer VM-X/VM-XP
Drill holes must always be filled from the bottom of the hole to ensure no air pockets are trapped in the adhesive. This is only possible when the tip of the mixing nozzle reaches the very bottom of the drill hole before injecting the adhesive. If the mixing nozzle does not reach the bottom of the drill hole, a mixer extension tube must be used.
mm
Außendurchmesser Mischer: ø 9,5 mmø 12 mm
ø 14 mmø 16 mm
ø 18 mmø 22 mm
ø 28 mm
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210
Outer diameter mixer:
2019 PR MKT
107 ... a solid connection
Ch
emic
al A
nch
ors
Chemical Anchors
Ch
emic
al A
nch
ors
Threaded Studs for the Injection System VMU plus in concrete: A �exible system means less inventoryThe �exible anchoring depths of the Injection System VMU plus make it possible to adjust the setting depths to the required load. This allows at low loads, the use of shorter anchor rods with correspondingly shorter drilling depths, high loads can be supported by correspondingly deeper anchorage depths.
All anchor rod groups from the existing MKT range listed below can be used with the Injection System VMU plus. But these anchor rods can, according to the applied load, be set deeper or shallower. The minimum and maximum possible anchorage depths are speci�ed in the assessment for each diameter and can be found in the extract from Permissible Service Conditions of ETA-11/0415 on the following pages.
Variable anchorage depth:
hef + t�x = Usable length of the threaded rod(without nut and washer)
Minimumsetting depths
Standardanchorage depth
Maximimanchorage depth
Threaded Stud VMU-A A4Stainless steel A4
May be used in structures subject to dry internal conditions or to external atmospheric exposure
Description Ref. No. Usable length in concrete
mm
Pkg.cont.pcs.
Weight per pkg.
kg
VMU-A 8x100 A4 31510501 90 10 0,42
VMU-A 8x110 A4 31515501 100 10 0,46
VMU-A 8x130 A4 31525501 120 10 0,52
VMU-A 8x145 A4 31528501 135 10 0,55
VMU-A 8x160 A4 31530501 150 10 0,60
VMU-A 8x205 A4 31550501 195 10 0,74
VMU-A 10x110 A4 31605501 100 10 0,75
VMU-A 10x130 A4 31625501 120 10 0,85
VMU-A 10x150 A4 31630501 140 10 0,95
VMU-A 10x165 A4 31635501 155 10 1,02
VMU-A 10x190 A4 31645501 180 10 1,15
VMU-A 10x260 A4 31655501 250 10 1,50
VMU-A 12x120 A4 31717501 105 10 1,14
VMU-A 12x130 A4 31718501 115 10 1,21
VMU-A 12x135 A4 31710501 120 10 1,25
VMU-A 12x155 A4 31720501 140 10 1,42
VMU-A 12x175 A4 31730501 160 10 1,54
VMU-A 12x185 A4 31734501 170 10 1,63
VMU-A 12x210 A4 31740501 195 10 1,82
VMU-A 12x225 A4 31748501 210 10 1,89
VMU-A 12x250 A4 31750501 235 10 2,13
VMU-A 12x265 A4 31757501 250 10 2,18
VMU-A 12x300 A4 31760501 285 10 2,50
VMU-A 16x160 A4 31810501 140 10 2,65
VMU-A 16x175 A4 31815501 155 10 2,85
VMU-A 16x205 A4 31820501 185 10 3,25
VMU-A 16x235 A4 31830501 215 10 3,65
VMU-A 16x300 A4 31840501 280 10 4,53
VMU-A 20x240 A4 31910501 220 10 5,85
VMU-A 20x285 A4 31920501 265 10 6,75
VMU-A 20x300 A4 31925501 280 10 7,15
VMU-A 24x290 A4 31960501 265 5 4,95
VMU-A 24x350 A4 31965501 325 5 5,85
VMU-A 24x400 A4 31970501 375 5 6,60
VMU-A 30x370 A4 31990501 340 5 9,90
Threaded Stud VMU-ASteel, zinc plated 5.8
May be used in structures subject to dry internal conditions
Description Ref. No. Usable length in concrete
mm
Pkg.cont.pcs.
Weight per pkg.
kg
VMU-A 8x100 31510101 90 10 0,42
VMU-A 8x110 31515101 100 10 0,46
VMU-A 8x130 31525101 120 10 0,52
VMU-A 8x145 31528101 135 10 0,55
VMU-A 8x160 31530101 150 10 0,60
VMU-A 8x205 31550101 195 10 0,74
VMU-A 10x110 31605101 100 10 0,75
VMU-A 10x130 31625101 120 10 0,85
VMU-A 10x150 31630101 140 10 0,95
VMU-A 10x165 31635101 155 10 1,02
VMU-A 10x190 31645101 180 10 1,15
VMU-A 10x260 31655101 250 10 1,50
VMU-A 12x120 31717101 105 10 1,14
VMU-A 12x130 31718101 115 10 1,21
VMU-A 12x135 31710101 120 10 1,25
VMU-A 12x155 31720101 140 10 1,42
VMU-A 12x175 31730101 160 10 1,54
VMU-A 12x185 31734101 170 10 1,63
VMU-A 12x210 31740101 195 10 1,82
VMU-A 12x225 31748101 210 10 1,89
VMU-A 12x250 31750101 235 10 2,13
VMU-A 12x265 31757101 250 10 2,18
VMU-A 12x300 31760101 285 10 2,50
VMU-A 16x160 31810101 140 10 2,65
VMU-A 16x175 31815101 155 10 2,85
VMU-A 16x205 31820101 185 10 3,25
VMU-A 16x235 31830101 215 10 3,65
VMU-A 16x300 31840101 280 10 4,53
VMU-A 20x240 31910101 220 10 5,85
VMU-A 20x260 31915101 240 10 6,30
VMU-A 20x285 31920101 265 10 6,75
VMU-A 20x300 31925101 280 10 7,15
VMU-A 20x350 31930101 330 10 8,10
VMU-A 20x400 31935101 380 10 9,10
VMU-A 24x290 31960101 265 5 4,95
VMU-A 24x350 31965101 325 5 5,85
VMU-A 24x400 31970101 375 5 6,60
VMU-A 30x370 31990101 340 5 9,90
Threaded Studs for applications in cracked and non-cracked concrete
Steel, zinc plated grade 8.8 on demand or as threaded studs VM-A Stainless steel HCR (1.4529) on demand
hef min t�x max
hef max t�x min
hef t�x
2019 PR MKT
108... a solid connection
Injection System for cracked concrete, non-cracked concrete and brickwork
Threaded Studs and Internally Threaded Sleeves for applications in cracked and non-cracked concrete
Description Ref. No. Thread Length
mm
Package contentpcs.
Weight per pkg.
kg
VM-A 8x1000 31199101 M8 1000 10 3,91
VM-A 10x1000 31299101 M10 1000 10 5,5
VM-A 12x1000 31399101 M12 1000 10 7,76
VM-A 16x1000 31599101 M16 1000 10 13,6
VM-A 20x1000 31699101 M20 1000 5 10,8
VM-A 24x1000 31799101 M24 1000 5 15,35
Threaded Stud VM-ASteel, zinc plated 5.8
Threaded studs, of 1 meter length, to be cut to the required length
Comes with manufacturer‘s certi�cate (3.1 EN10204) in every package
Description Ref. No. Thread Length
mm
Package contentpcs.
Weight per pkg.
kg
VM-A 8x1000 8.8 31199181 M8 1000 10 3,91
VM-A 10x1000 8.8 31299181 M10 1000 10 5,5
VM-A 12x1000 8.8 31399181 M12 1000 10 7,76
VM-A 16x1000 8.8 31599181 M16 1000 10 13,6
Threaded Stud VM-ASteel, zinc plated 8.8
Threaded studs, of 1 meter length, to be cut to the required length
Comes with manufacturer‘s certi�cate (3.1 EN10204) in every package
Description Ref. No. Thread Length
mm
Package contentpcs.
Weight per pkg.
kg
VM-A 8x1000 A4 31199501 M8 1000 10 3,77
VM-A 10x1000 A4 31299501 M10 1000 10 5,43
VM-A 12x1000 A4 31399501 M12 1000 10 8,03
VM-A 16x1000 A4 31599501 M16 1000 10 13,95
VM-A 20x1000 A4 31699501 M20 1000 5 11,0
VM-A 24x1000 A4 31799501 M24 1000 5 15,6
Threaded Stud VM-A Stainless steel A4
Threaded studs, of 1 meter length, to be cut to the required length
Comes with manufacturer‘s certi�cate (3.1 EN10204) in every package
Description Ref. No. Outer-Ø
x Lengthmm
Thread depthmin / max
mm
Package content
pcs.
Weight
per pkg.kg
Steel, zinc plated Stainless steel A4 Drill hole-Ø x depthmm
VMU-IG M6x80 31502101 31502501 12 x 80 10 x 80 8 / 20 10 0,38
VMU-IG M6x90 31503101 31503501 12 x 90 10 x 90 8 / 20 10 0,42
VMU-IG M8x80 31562101 31562501 14 x 80 12 x 80 8 / 20 10 0,52
VMU-IG M8x100 31563101 31563501 14 x 100 12 x 100 8 / 20 10 0,66
VMU-IG M10x80 31601101 31601501 18 x 80 16 x 80 10 / 25 10 0,92
VMU-IG M10x100 31602101 31602501 18 x 100 16 x 100 10 / 25 10 1,18
VMU-IG M12x125 31652101 31652501 24 x 125 20 x 125 12 / 30 10 2,51
VMU-IG M16x170 31702101 31702501 28 x 170 24 x 170 16 / 32 5 2,41
Internally Threaded Sleeve VMU-IGSteel, zinc plated 5.8/Stainless steel A4
With internal thread
For cracked and non-cracked concrete
For use in structures subject to dry internal conditions
For use in structures subject to dry internal conditions
Threaded Stud V-ASteel, zinc plated 5.8Dimensions see page 144
Threaded Stud V-A 8.8Steel, zinc plated 8.8Dimensions see page 144
For use in structures subject to dry internal conditions
Threaded Stud V-A fvzSteel, hot dip galvanized 5.8Dimensions see page 144 Steel hot dip galvanized 8.8 on demand
For use in structures subject to dry internal conditions or external atmospheric exposure
For use in particularly corrosive environments
Threaded Stud V-A A4Stainless steel A4Dimensions see page 144
Threaded Stud V-A HCRStainless steel HCRDimensions see page 144
High corrosion resistant steel 1.4529 (HCR)
Other dimensions on demand.
NE
WN
EW
2019 PR MKT
109 ... a solid connection
Ch
emic
al A
nch
ors
Chemical Anchors
Ch
emic
al A
nch
ors
Description Ref. No. Usable length
mm
Solid base material without SH Solid and hollow base material with VM-SH Package content
Pcs.
Weight per pkg.
kg
Steel, zinc plated Stainless steel A4 Drill hole-Ø x depth
mm
Maximum Fixture thick-
ness t�x
mm
VM-SH 12x85 VM-SH 16x90 VM-SH 16x135 VM-SH 20x90 VM-SH 20x135 VM-SH 20x205
Drill hole Ø x depth mm
12x85 16x90 16x135 20x90 20x135 20x205
Maximum Fixture thickness t�x mm
VMU-A 8 x 100 31510101 31510501 90 10 x 80 10 10 5 - - - - 10 0,42VMU-A 8 x 110 31515101 31515501 100 10 x 80 20 20 15 - - - - 10 0,46VMU-A 8 x 130 31525101 31525501 120 10 x 80 40 40 35 - - - - 10 0,52VMU-A 8 x 145 31528101 31528501 135 10 x 80 55 55 50 5 - - - 10 0,55VMU-A 8 x 160 31530101 31530501 150 10 x 80 70 70 65 20 - - - 10 0,60VMU-A 8 x 205 31550101 31550501 195 10 x 80 115 115 110 65 - - - 10 0,74VMU-A 10 x 110 31605101 31605501 100 12 x 90 10 - 15 - - - - 10 0,75VMU-A 10 x 130 31625101 31625501 120 12 x 90 30 - 35 - - - - 10 0,85VMU-A 10 x 150 31630101 31630501 140 12 x 90 50 - 55 10 - - - 10 0,95VMU-A 10 x 165 31635101 31635501 155 12 x 90 65 - 70 25 - - - 10 1,02VMU-A 10 x 190 31645101 31645501 180 12 x 90 90 - 95 50 - - - 10 1,15VMU-A 10 x 260 31655101 31655501 250 12 x 90 160 - 165 120 - - - 10 1,50VMU-A 12 x 120 31317101 31717501 105 14 x 100 5 - - - 20 - - 10 1,14VMU-A 12 x 130 31718101 31718501 115 14 x 100 15 - - - 30 - - 10 1,21VMU-A 12 x 135 31710101 31710501 120 14 x 100 20 - - - 35 - - 10 1,25VMU-A 12 x 155 31720101 31720501 140 14 x 100 40 - - - 55 10 - 10 1,42VMU-A 12 x 175 31730101 31730501 160 14 x 100 60 - - - 75 30 - 10 1,54VMU-A 12 x 185 31734101 31734501 170 14 x 100 70 - - - 85 40 - 10 1,63VMU-A 12 x 210 31740101 31740501 195 14 x 100 95 - - - 110 65 - 10 1,82VMU-A 12 x 225 31748101 31748501 210 14 x 100 110 - - - 125 80 10 10 1,89VMU-A 12 x 250 31750101 31750501 235 14 x 100 135 - - - 150 105 35 10 2,13VMU-A 12 x 265 31757101 31757501 250 14 x 100 150 - - - 165 120 50 10 2,18VMU-A 12 x 300 31760101 31760501 285 14 x 100 185 - - - 200 155 85 10 2,50VMU-A 16 x 160 31810101 31810501 140 18 x 100 40 - - - 55 10 - 10 2,65VMU-A 16 x 175 31815101 318015501 155 18 x 100 55 - - - 70 25 - 10 2,85VMU-A 16 x 205 31820101 31820501 185 18 x 100 85 - - - 100 55 - 10 3,25VMU-A 16 x 235 31830101 31830501 215 18 x 100 115 - - - 130 85 15 10 3,65VMU-A 16 x 300 31840101 31840501 280 18 x 100 180 - - - 195 150 80 10 4,53
Threaded Stud VMU-ASteel, zinc plated 5.8/Stainless steel A4
Steel hot dip galvanized and stainless steel HCR (1.4529) on demand
Threaded Studs, Internally Threaded Sleeves and Perfo Sleeves for applications in solid and hollow base material
Description Ref. No. Drill hole Ø x depthmm
For threaded studs For internally threaded sleeves Appropiate for cleaning brush
Package content
Pcs.
Weight per pkg.
kg
VM-SH 12 x 80 28151201 12 x 85 M8 - RB 12 M6 10 0,02
VM-SH 16 x 85 28152001 16 x 90 M8 / M10 VMU-IG M6 x 80 RB 16 M6 10 0,03
VM-SH 16 x 130 28153001 16 x 135 M8 / M10 - RB 16 M6 10 0,04
VM-SH 20 x 85 28154001 20 x 90 M12 / M16 VMU-IG M8 x 80/VMU-IG M10 x 80 RB 20 M6 10 0,04
VM-SH 20 x 130 28154301 20 x 135 M12 / M16 - RB 20 M6 10 0,07
VM-SH 20 x 200 28154601 20 x 205 M12 / M16 - RB 20 M6 10 0,10
Perfo Sleeve VM-SHPolypropylen
Approved for hollow base materialPolypropylen
Description Ref. No. Solid base material without SH
Solid and hollow base material with SH
Outer-Ø x Length
mm
Thread depth
min / maxmm
Package
content
pcs.
Weight per pkg.
kg
Steel, zinc plated Stainless steel A4Drill hole Ø x depth
mm
VM-SH 16x85Drill holeØ x depth
mm
VM-SH 20x85Drill hole-Ø x depth
mm
VMU-IG M6x80 31502101 31502501 - 16 x 90 - 10 x 80 8 / 20 10 0,38
VMU-IG M6x90 31503101 31503501 12 x 90 - - 10 x 90 8 / 20 10 0,42
VMU-IG M8x80 31562101 31562501 - - 20 x 90 12 x 80 8 / 20 10 0,52
VMU-IG M8x100 31563101 31563501 14 x 100 - - 12 x 100 8 / 20 10 0,60
VMU-IG M10x80 31601101 31601501 - - 20 x 90 16 x 80 10 / 25 10 0,92
VMU-IG M10x100 31602101 31602501 18 x 100 - - 16 x 100 10 / 25 10 1,18
Internally Threaded Sleeve VMU-IGSteel, zinc plated 5.8/Stainless steel A4
With internal thread
Approved for solid and hollow base material
2019 PR MKT
110... a solid connection
Injection System for cracked concrete, non-cracked concrete and brickwork
Description Ref. No. Length
mm
Ø
mm
To use in conjunction
with
Pkg. cont.pcs.
Weight per pkg.
kg
VM-XE 10/200 28306011 200 10 VM-XL, VM-X 12 0,12
VM-XE 10/500 85951101 500 10 VM-XL, VM-X 10 0,20
VM-XE 10/1000 85952101 1000 10 VM-XL, VM-X 10 0,30
VM-XLE 16/250 85959101 250 16 VM-XL 10 0,30
VM-XLE 16/1000 85956101 1000 16 VM-XL 10 1,15
Extension tubes for deeper drill holesExtension tubes
Accessories
Description Ref. No. Suitable for drill hole Ø
mm
Total length of brushmm
Suitable for Pkg. cont. pcs.
Weight per piece
kgThreaded stud Internally threaded sleeve
RB 10 M6 33510101 10 130 M8 - 1 0,05
RB 12 M6 33512101 12 140 M10 Ø8 1 0,05
RB 14 M6 33514101 14 180 M12 Ø10 1 0,05
RB 16 M6 33516101 16 200 - Ø12 1 0,05
RB 18 M6 33518101 18 200 M16 Ø14 1 0,05
RB 20 M6 33520101 20 220 - Ø16 1 0,05
RB 24 M6 33524101 24 250 M20 Ø20 1 0,06
RB 26 M6 33526101 25,26 290 - Ø20 1 0,06
RB 28 M6 33528101 28 260 M24 Ø22 1 0,06
RB 32 M6 33532101 32 350 M27 Ø24,25 1 0,08
RB 35 M6 33535101 35 350 M30 Ø28 1 0,08
RB 40 M6 33537101 40 350 - Ø32 1 0,08
RBL M6 33968101 Brush extention 150 mm with connection thread M6 1 0,09
RBL M6 SDS 33350101 SDS Plus adapter with internal thread (M6) 1 0,06
Cleaning brush RB M6With connection thread M6
Extensions for large depths
For drilling machines with keyed chuck or with SDS plus adaptor for SDS plus drill holder
Direct clamping into the drilling machine with toothed drill chuck is possible
Description Ref. No. Suitable for drill hole
Ø mm
Color Suitable for Pkg. cont.
pcs.
Weight per pkg.
kgThreaded
studRebar
VM-IA 14 85914201 14 black M12 Ø10 20 0,02
VM-IA 16 85916201 16 black - Ø12 20 0,02
VM-IA 18 85918201 18 black M16 Ø14 20 0,02
VM-IA 20 85920201 20 black - Ø16 20 0,06
VM-IA 24 85924101 24 black M20 Ø20 20 0,06
VM-IA 25 85925201 25 black - Ø20 20 0,06
VM-IA 28 85928101 28 black M24 Ø22 20 0,08
VM-IA 32 85932201 32 black M27 Ø24, 25 20 0,08
VM-IA 35 85935201 35 black M30 Ø28 20 0,08
VM-IA 40 85938201 40 black Ø32 20 0,08
Retaining Washer VM-IAFor bubble-free �lling of the drill hole
Suitable for extension tubes VM-XE 10 and VM-XLE 16
VM-XE 10
VM-XLE 16
Two diameters available
Possible combinations static mixer / Extension tube / Retaining Washer:
VM-XE 10VM-IA VM-X/VM-XP VM-XE 10VM-IA VM-XL
VM-XLE 16VM-IA VM-XL
VM-XE 10
VM-XLE 16
VM-XLE 16VME-IA VM-XL
Description Ref. No. Hose Ø
mm
For drill hole Ø
mm
Max. drill holedepth2)
mm
Pkg.cont.pcs
Weight per piece
kg
Blow-out pump VM-AP 360 33200101 8 81)-20 330 1 0,27
Blow-out pump VM-AP
1)With extension tube Ø 6 x 100mm2)For through fastening: Maximum drill hole depth through �xture
For best drill hole cleaning, the hose must reach the bottom of the drill hole
For assessment-compliant air-cleaning of drill holes in masonry as well as non-cracked concrete with a diameter up to 20 mm and a maximum drill hole depth ten times larger than the diameter of the threaded stud (VMU plus)
2019 PR MKT
111 ... a solid connection
Chemical Anchors
Ch
emic
al A
nch
ors
Description Ref. No. Suitable for cartridge Pkg. cont. pcs
Weight per piecekg
VM-P 345 Profi 28350511 150ml, 280ml, 300ml, 345ml also suitable for silicone cartriges 1 1,00
VM-P 380 Profi 28351001 380ml, 410ml, 420ml 1 1,10
Dispenser VM-P ProfiProfessional dispenser with an ideal center of gravity for more comfortable working
Automatic pressure realease for minimum adhesive overrun
Description Ref. No. Suitable for cartridge Pkg. cont. pcs
Weight per piecekg
VM-P 345 Standard 28350505 150ml, 280ml, 300ml, 345ml also suitable for silicone cartriges 1 1,00
VM-P 380 Standard 28353005 380ml, 410ml, 420ml 1 1,15
Dispenser VM-P StandardFor occasional use, metal version
Piston rod with adjusting screw
Description Ref. No. Suitable for cartridge Pkg. cont. pcs
Weight per piecekg
VM-P 345 Pneumatic 28350601 280ml, 300ml, 345ml max. working pressure 8 bar, 40l/min 1 2,41
VM-P 380 Pneumatic 28352002 380ml, 410ml, 420ml max. working pressure 8 bar, 40l/min 1 2,00
VM-P 825 Pneumatic 28352110 825ml max. working pressure 8 bar, 40l/min 1 5,00
Dispenser VM-P PneumaticProfessional air tool with an optimum center of gravity and quick cartridge exchange
Automatic pressure release system reduces adhesive overrun to a minimum
Single-hand pressure regulation to adjust the piston speed
Description Ref. No. Suitable for cartridge Press-out force
kN
Weight1)
kg
Dimensions 1) L x B x H
mm
Pkg. cont. pcs
Weight per piece
kg
VM-P 345 Akku 28350801 345ml 5,0 3,53 395 x 180 x 285 1 7,72
VM-P 380 Akku 28352601 380ml, 410ml, 420ml 3,95 3,62 375 x 180 x 285 1 7,80
VM-P 585 Akku 28353301 385ml, 585ml 5,0 3,86 440 x 180 x 285 1 8,05
Accessories (for all models)
Replacement battery 28352411 18 V/2,0 Ah 1 1,00
Shoulder strap 28359991 adjustable 1 0,02
Dispenser VM-P AkkuProfessional, solid battery cartridge dispenser in a plastic case
Repeat function, for retrieving the last �ll quantity
Stepless variable pressing speed
Overrun-quantity-stop by automatic return after release of the dispending switch
1) with Akku 18V/2,0 Ah
With compressed air connection nipple
Description
Ref. No. Nozzle-ø
mm
For drill hole Ø
mm
Max. drill holedepth1)
mm
Pkg.cont.pcs.
Weight per piece
kg
VM-ABP 200 33090101 5 6-20 240 1 0,55
VM-ABP 250 33100101 16 18-40 240 1 1,00
VM-ABP 500 33106101 16 18-40 480 1 1,30
Air gun VM-ABP For assessment-compliant drill hole cleaning with compressed air for drill holes with a diameter larger than 6 mm
1)For through fastening: Maximum drill hole depth through �xture
For best drill hole cleaning, the nozzle of the air gun must reach the bottom of the drill hole
Description Ref. No. Nozzle Ø
mm
Max. Drill hole depthmm
For drill hole Ømm
Pkg.cont.pcs
Weight per piece
kg
VM-ABP 1000 85806101 14 1000 16-40 1 0,32
Air gun VM-ABPDrill hole cleaning with compressed air for holes up to one meter
For best drill hole cleaning the nozzle of the air-gun must reach to the bottom of the drill hole
2019 PR MKT
112... a solid connection
Injection System for cracked concrete, non-cracked concrete and brickwork
Description Ref. No. Suitable for drill hole-Ø
mm
Pkg.content
pcs.
Weight per piece
kg
VME System case 85999101 12 - 35 1 11,8
Drilling:- Drilling aid device- Flat- / Ring wrenchAccessories for drill hole cleaning:- 1 of each air hose RS 25 and RS 35- 1 of each blow-out nozzle RD 12/14, 16/18, 20/25, 30/35- 1 of each cleaning brush RB 12 M8 – RB 35 M8- Connection set RS with air valve and connector- 5 Brush extensions RBL M8, L = 500 mm- 1 SDS-plus adapter RBL M8-SDSAccessories for injection:- 5 Static mixer VM-XL- 5 of each retaining washer VM-IA Ø12 mm - Ø35 mm - 5 of each extension tube VM-XE 10/500 and VM-XLE 16/500- Frame sawOther:- European Technical Assessment and Approval- Installation sheet and Installation report (available for download at www.mkt.de)- Filling quantity tables- Adhesive tape- Measuring tape- Thermometer- Ear protection, Breathing protection, Protective goggles and protective gloves
Compact system case including equipment for every rebar diameter as well as all the tools necessary for the installation of post-installed rebar connections using the Injection System VME or VMU plus. All parts also sold separately.
Description and content:
System case and accessories for post-installed rebar connections to use with injection system VMU plus (fast curing time) or the injection system VME (long curing times, optimized for very large and deep drill holes)
System ComponentsFilling of drill hole
For drill hole diameter 12 - 35 mm
Reinforced brushes RB M8Reinforced brushes with connecting thread M8 for
deeper drill holes
Blow-out nozzleEvery nozzle covers two drill hole diameters
Fits on the air hose RS
For drill hole cleaning with compressed air
pre-assembled set with connectorsAir hose
Air Valve
Description Ref. No. Length
mm
Rebar- Ø
mm
Suitable for drill hole Ø
mm
Colour Packagecontent
pcs.
Weight per pkg.
kg
Extension pipeVM-XE 10/1000 85952101 1000 8 - 12 12 - 16 white 10 0,30VM-XE 10/2000 85954101 2000 8 - 12 12 - 16 white 10 0,65VM-XLE 16/1000 85956101 1000 14 - 28 18 - 35 grey 10 1,15VM-XLE 16/2000 85958101 2000 14 - 28 18 - 35 grey 10 3,50Retaining washer (only for post-installed rebar connections. Fits to the system case)VME-IA 12 85912101 - 8 12 white 20 0,04VME-IA 14 85914101 - 10 14 yellow 20 0,01VME-IA 16 85916101 - 12 16 blue 20 0,02VME-IA 18 85918101 - 14 18 black 20 0,01VME-IA 20 85920101 - 16 20 grey 20 0,02VME-IA 25 85925101 - 20 25 green 20 0,05VME-IA 32 85932101 - 25 32 brown 20 0,10VME-IA 35 85935101 - 28 35 red 20 0,12
Extension pipe VM-XE and VM-XLE can be cut to corresponding drill hole depth. Extension pipe > 2000 mm on demand.
Description Ref. No. Rebar- Ø
mm
Suitable for drill hole Ø
mm
Pkg.content
pcs.
Weight per piece
kg
RB 12 M8 85812101 8 12 1 0,05RB 14 M8 85814101 10 14 1 0,05RB 16 M8 85816101 12 16 1 0,05RB 18 M8 85818101 14 18 1 0,05RB 20 M8 85820101 16 20 1 0,05RB 25 M8 85825101 20 25 1 0,06RB 32 M8 85832101 25 32 1 0,08RB 35 M8 85835101 28 35 1 0,08Brush extension RBL M8, L= 500 mm 85871101 8 - 28 12 - 35 1 0,32SDS-Plus adapter RBL M8 SDS 85881101 - 12 - 35 1 0,07
Please select Brush extension RBL and SDS-Plus adapter according to depth of drill hole.For drill hole depth > 500 mm, the proper number of Brush extensions must be connected.
Description Ref. No. Rebar- Ø
mm
Suitable for drill hole-Ø
mm
Pkg.content
pcs.
Weight per piece
kg
Blow-out nozzle RD 12/14 85852101 8 - 10 12 - 14 1 0,01Blow-out nozzle RD 16/18 85854101 12 - 14 16 - 18 1 0,02Blow-out nozzle RD 20/25 85856101 16 - 20 20 - 25 1 0,03Blow-out nozzle RD 30/35 85858101 24 - 28 30 - 35 1 0,05
Description Ref. No. Rebar- Ø
mm
Suitable for drill hole-Ø
mm
Pkg.content
pcs.
Weight per piece
kg
Air hose RS 25 (2 m) 85802101 8 - 20 12 - 25 1 0,10Air hose RS 35 (3 m) 85804101 24 - 28 30 - 35 1 0,40
Description Ref. No. Rebar- Ø
mm
Suitable for drill hole-Ø
mm
Pkg.content
pcs.
Weight per piece
kg
Connection Set RS with valve and connector 85890101 8 - 28 12 - 35 1 0,40
To use with air valve and blow-out nozzle
2019 PR MKT
113 ... a solid connection
Chemical Anchors
Ch
emic
al A
nch
ors
Loads and performance data
M12 M16 M20 M24 M27 M30Injection System VMU plus, threaded stud steel 5.8 M8 M10
Range of anchorage depths hef,min - hef,max [mm] 60 - 160 60 - 200 70 - 240 80 - 320 90 - 400 96 - 480 108 - 540 120 - 600
Approved loads, tension for hef,min - hef,max cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. N [kN] 2,9-7,7 3,7-12,5 5,8-19,7 8,8-35,1 12,2-54,9 13,4-79,0 16,0-109,5 18,8-133,3
50°C/80°C 1) C20/25 appr. N [kN] 1,8-4,8 2,6-8,7 4,2-14,4 6,4-25,5 9,0-39,9 11,5-57,4 16,0-81,8 18,8-101,0
Approved loads, tension for hef,min - hef,max non-cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. N [kN] 7,2-8,6 9,0-13,8 11,7-20,0 14,3-37,1 17,1-58,1 18,8-83,8 22,5-109,5 26,3-133,3
50°C/80°C 1) C20/25 appr. N [kN] 5,4-8,6 6,7-13,8 9,4-20,0 14,3-37,1 17,1-58,1 18,8-83,8 22,5-109,5 26,3-133,3
Approved loads, shear for für hef,min - hef,max cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. V [kN] 5,1 8,6 12,0 21,1-22,3 29,3-34,9 32,2-50,3 38,5-65,7 45,1-80,0
50°C/80°C 1) C20/25 appr. V [kN] 3,6-5,1 6,3-8,6 10,1-12,0 15,3-22,3 21,5-34,9 27,6-50,3 38,5-65,7 45,1-80,0
Approved loads, shear for hef,min - hef,max non-cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. V [kN] 5,1 8,6 12,0 22,3 34,9 45,2-50,3 54,0-65,7 63,2-80,0
50°C/80°C 1) C20/25 appr. V [kN] 5,1 8,6 12,0 22,3 34,9 45,2-50,3 54,0-65,7 63,2-80,0
Injection System VMU plus, threaded stud steel 8.8 M8 M10 M12 M16 M20 M24 M27 M30Range of anchorage depths hef,min - hef,max [mm] 60 - 160 60 - 200 70 - 240 80 - 320 90 - 400 96 - 480 108 - 540 120 - 600
Approved loads, tension for hef,min - hef,max cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. N [kN] 2,9-7,7 3,7-12,5 5,8-19,7 8,8-35,1 12,2-54,9 13,4-79,0 16,0-118,1 18,8-145,9
50°C/80°C 1) C20/25 appr. N [kN] 1,8-4,8 2,6-8,7 4,2-14,4 6,4-25,5 9,0-39,9 11,5-57,4 16,0-81,8 18,8-101,0
Approved loads, tension for hef,min - hef,max non-cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. N [kN] 7,2-13,8 9,0-21,9 11,7-31,9 14,3-59,5 17,1-93,3 18,8-134,3 22,5-175,2 26,3-202,0
50°C/80°C 1) C20/25 appr. N [kN] 5,4-13,8 6,7-21,9 9,4-31,9 14,3-57,4 17,1-89,8 18,8-122,1 22,5-136,3 26,3-145,9
Approved loads, shear for hef,min - hef,max cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. V [kN] 5,7-8,6 9,0-13,1 13,8-19,4 21,1-36,0 29,3-56,0 32,2-80,6 38,5-105,1 45,1-128,0
50°C/80°C 1) C20/25 appr. V [kN] 3,6-8,6 6,3-13,1 10,1-19,4 15,3-36,0 21,5-56,0 27,6-80,6 38,5-105,1 45,1-128,0
Approved loads, shear for for hef,min - hef,max non-cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. V [kN] 8,6 13,1 19,4 34,4-36,0 41,1-56,0 45,2-80,6 54,0-105,1 63,2-128,0
50°C/80°C 1) C20/25 appr. V [kN] 8,6 13,1 19,4 34,4-36,0 41,1-56,0 45,2-80,6 54,0-105,1 63,2-128,0
Extract from Permissible Service Conditions of European Technical Assessment ETA-11/0415 Approved loads without in�uence of spacing and edge distance in dry or wet concrete for temperature range I -40°C to +24°C/+40°C1) and for temperature range II -40°C to +50°C/+80°C1) (For temperature range III -40°C to +72°C/+120°C1) see ETA-11/0415).Total safety factor as per ETAG 001 included (γM and γF). Load capacities under �re exposure see page 168.
M12 M16 M20 M24 M27 M30Injection System VMU plus, threaded stud stainless steel A4-702), HCR-702) M8 M10
Range of anchorage depths hef,min - hef,max [mm] 60 - 160 60 - 200 70 - 240 80 - 320 90 - 400 96 - 480 108 - 540 120 - 600
Approved loads, tension for hef,min - hef,max cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. N [kN] 2,9-7,7 3,7-12,5 5,8-19,7 8,8-35,1 12,2-54,9 13,4-79,0 16,0-57,4 18,8-70,2
50°C/80°C 1) C20/25 appr. N [kN] 1,8-4,8 2,6-8,7 4,2-14,4 6,4-25,5 9,0-39,9 11,5-57,4 16,0-57,4 18,8-70,2
Approved loads, tension for hef,min - hef,max non-cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. N [kN] 7,2-9,9 9,0-15,7 11,7-22,5 14,3-42,0 17,1-65,3 18,8-94,3 22,5-57,4 26,3-70,2
50°C/80°C 1) C20/25 appr. N [kN] 5,4-9,9 6,7-15,7 9,4-22,5 14,3-42,0 17,1-65,3 18,8-94,3 22,5-57,4 26,3-70,2
Approved loads, shear for hef,min - hef,max cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. V [kN] 5,7-6,0 9,0-9,2 13,7 21,1-25,2 29,3-39,4 32,2-56,8 34,5 42,0
50°C/80°C 1) C20/25 appr. V [kN] 3,6-6,0 6,3-9,2 10,1-13,7 15,3-25,2 21,5-39,4 27,6-56,8 34,5 42,0
Approved loads, shear for hef,min - hef,max non-cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. V [kN] 6,0 9,2 13,7 25,2 39,4 45,2-56,8 34,5 42,0
50°C/80°C 1) C20/25 appr. V [kN] 6,0 9,2 13,7 25,2 39,4 45,2-56,8 34,5 42,0
Higher concrete strength may lead to higher approved loads. Technical data for water-�lled drill holes see approval.
1) Max. long term temperature / max. short term temperature 2)M27, M30: A4-50, HCR-50
Spacing and edge distance
Min. thickness of concrete slab for hef,min - hef,max hmin [mm] 100-190 100-230 100-270 116-356 138-448 152-536 172-604 190-670
Minimum spacing smin [mm] 40 50 60 80 100 120 135 150
Minimum edge distance cmin [mm] 40 50 60 80 100 120 135 150
Installation parameters
Drill hole diameter do [mm] 10 12 14 18 24 28 32 35
Clearance hole in the �xture df [mm] 9 12 14 18 22 26 30 33
Range of drill hole depth for hef,min - hef,max ho [mm] 60 - 160 60 - 200 70 - 240 80 - 320 90 - 400 96 - 480 108 - 540 120 - 600
Installation torque Tinst < [Nm] 10 20 40 80 120 160 180 200
Amount of mortar per 100 mm drill ole depth [ml] 6,53 8,16 9,82 13,61 26,71 32,25 42,03 48,70
For anchor designing, an easy to operate Software is available on request or can be downloaded at www.mkt.de
2019 PR MKT
114... a solid connection
Injection System for cracked concrete, non-cracked concrete and brickwork
Loads and performance data
Internally threaded sleeve IG M6 x 80 IG M6 x 90 IG M8 x 80 IG M8 x 100 IG M10 x 80 IG M10 x 100 IG M12 x125 IG M16 x 170 IG M20 x 200
Anchorage depth hef [mm] 80 90 80 100 80 100 125 170 200
Injection System VMU plus, Internally threaded steel VMU-IG, Steel 5.8Approved loads, tension for hef cracked concrete
Temperature range 24°C/40°C 1) C20/25 appr. N [kN] 4,8 4,8 6,6 8,2 8,8 11,0 17,1 28,0 40,4
50°C/80°C 1) C20/25 appr. N [kN] 3,5 3,9 4,8 6,0 6,4 8,0 12,5 20,3 33,7
Approved loads, tension for hef non-cracked concrete
Temperature range 24°C/40°C 1) C20/25 appr. N [kN] 4,8 4,8 8,6 8,6 13,8 13,8 20,0 37,6 56,7
50°C/80°C 1) C20/25 appr. N [kN] 4,8 4,8 8,6 8,6 13,8 13,8 20,0 37,6 48,6
Approved loads, shear for hef cracked concrete
Temperature range 24°C/40°C 1) C20/25 appr. V [kN] 2,9 2,9 5,1 5,1 8,6 8,6 12,0 22,3 34,9
50°C/80°C 1) C20/25 appr. V [kN] 2,9 2,9 5,1 5,1 8,6 8,6 12,0 22,3 34,9
Approved loads, shear for hef non-cracked concrete
Temperature range 24°C/40°C 1) C20/25 appr. V [kN] 2,9 2,9 5,1 5,1 8,6 8,6 12,0 22,3 34,9
50°C/80°C 1) C20/25 appr. V [kN] 2,9 2,9 5,1 5,1 8,6 8,6 12,0 22,3 34,9
Injection System VMU plus, Internally threaded VMU-IG, Stainless steel A4-702), HCR-702)
Approved loads, tension for hef cracked concrete
Temperature range 24°C/40°C 1) C20/25 appr. N [kN] 5,0 5,3 6,6 8,2 8,8 11,0 17,1 28,0 31,0
50°C/80°C 1) C20/25 appr. N [kN] 3,5 3,9 4,8 6,0 6,4 8,0 12,5 20,3 31,0
Approved loads, tension for hef non-cracked concrete
Temperature range 24°C/40°C 1) C20/25 appr. N [kN] 5,3 5,3 9,9 9,9 14,3 15,7 22,5 42,0 31,0
50°C/80°C 1) C20/25 appr. N [kN] 5,3 5,3 9,9 9,9 14,3 15,7 22,5 42,0 31,0
Approved loads, shear for hef cracked concrete
Temperature range 24°C/40°C 1) C20/25 appr. V [kN] 3,2 3,2 6,0 6,0 9,2 9,2 13,7 25,2 18,6
50°C/80°C 1) C20/25 appr. V [kN] 3,2 3,2 6,0 6,0 9,2 9,2 13,7 25,2 18,6
Approved loads, shear for hef non-cracked concrete
Temperature range 24°C/40°C 1) C20/25 appr. V [kN] 3,2 3,2 6,0 6,0 9,2 9,2 13,7 25,2 18,6
50°C/80°C 1) C20/25 appr. V [kN] 3,2 3,2 6,0 6,0 9,2 9,2 13,7 25,2 18,6
Spacing and edge distanceMinimum thickness of concrete slab for hef hmin [mm] 110 120 110 130 116 136 169 226 270
Minimum spacing smin [mm] 50 50 60 60 80 80 100 120 150
Minimum edge distance cmin [mm] 50 50 60 60 80 80 100 120 150
Installation parametersDrill hole diameter do [mm] 12 12 14 14 18 18 24 28 35
Clearance hole in the �xture df ≤ [mm] 7 7 9 9 12 12 14 18 22
Range of drill hole depth for hef d0 [mm] 80 90 80 100 80 100 125 170 200
Installation Tinst ≤ [Nm] 10 10 10 10 20 20 40 60 100
Amount of adhesive per drill hole [ml] 6,6 7,4 7,9 9,9 10,9 13,6 33,4 54,9 97,4
Higher concrete strength may lead to higher approved loads. Technical data for water-�lled drill holes see approval. For anchor designing, an easy to operate Software is available on request or can be downloaded at www.mkt.de.
1) Max. long term temperature / max. short term temperature 2)IG M20 x 200: A4-50, HCR-50
Extract from Permissible Service Conditions of European Technical Assessment ETA-11/0415 Approved loads without in�uence of spacing and edge distance in dry or wet concrete for temperature range I -40°C to +24°C/+40°C1) and for temperature range II -40°C to +50°C/+80°C1) (For temperature range III -40°C to +72°C/+120°C1) see ETA-11/0415).Total safety factor as per ETAG 001 included (γM and γF).
2019 PR MKT
115 ... a solid connection
Chemical Anchors
Ch
emic
al A
nch
ors
Installation in concrete and solid base material
h m hmin
L
hef = h0 t�x
Tinst
d0
Nm
Tinst+20 °C
45 min.
90°
ø12 ø14 ø16 ø20 ø25 ø28 ø32Injection System VMU plus, reinforcement bars B500B ø8 ø10
Range of anchorage depths hef,min - hef,max [mm] 60-160 60-200 70-240 75-280 80-320 90-400 100-500 112-560 128-640
Approved loads, tension for hef,min - hef,max cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. N [kN] 2,9-7,7 3,7-12,5 5,8-19,7 7,2-26,9 8,8-35,1 12,2-54,9 14,3-85,7 16,9-127,1 20,7-166,0
50°C/80°C 1) C20/25 appr. N [kN] 1,8-4,8 2,6-8,7 4,2-14,4 5,2-19,5 6,4-25,5 9,0-39,9 12,5-63,3 16,9-88,0 20,7-114,9
Approved loads, tension for hef,min - hef,max non-cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. N [kN] 7,2-13,8 9,0-21,6 11,7-31,2 13,0-42,4 14,3-55,4 17,1-86,6 20,0-135,2 23,8-169,6 29,0-217,0
50°C/80°C 1) C20/25 appr. N [kN] 5,4-13,8 6,7-21,6 9,4-31,2 11,8-42,4 14,3-55,4 17,1-86,6 20,0-124,7 23,8-136,8 29,0-153,2
Approved loads, shear for hef,min - hef,max cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. V [kN] 5,7-6,5 9,0-10,1 13,8-14,5 17,3-19,8 21,1-25,9 29,3-40,4 34,3-63,1 40,6-79,2 49,7-103,4
50°C/80°C 1) C20/25 appr. V [kN] 3,6-6,5 6,3-10,1 10,1-14,5 12,6-19,8 15,3-25,9 21,5-40,4 29,9-63,1 40,6-79,2 49,7-103,4
Approved loads, shear for hef,min - hef,max non-cracked concrete
Range of temperature 24°C/40°C 1) C20/25 appr. V [kN] 6,5 10,1 14,5 19,8 25,9 40,4 48,1-63,1 57,0-79,2 69,6-103,4
50°C/80°C 1) C20/25 appr. V [kN] 6,5 10,1 14,5 19,8 25,9 40,4 48,1-63,1 57,0-79,2 69,6-103,4
Spacing and edge distanceMin. thickness of concrete slab for hef,min - hef,max hmin [mm] 100-190 100-230 102-272 111-316 120-360 138-448 164-564 182-630 208-720
Minimum spacing smin [mm] 40 50 60 70 80 100 125 140 160
Minimum edge distance cmin [mm] 40 50 60 70 80 100 125 140 160
Installation parametersDrill hole diameter do [mm] 12 14 16 18 20 24 32 35 40
Range of drill hole depth for hef,min - hef,max ho [mm] 60 - 160 60 - 200 70 - 240 75-280 80 - 320 90 - 400 100 - 500 112 - 560 128-640
Higher concrete strength may lead to higher approved loads. Technical data for water-�lled drill holes see approval.
1) Max. long term temperature / max. short term temperature
Extract from Permissible Service Conditions of European Technical Assessment ETA-11/0415 Approved loads without in�uence of spacing and edge distance in dry or wet concrete for temperature range I -40°C to +24°C/+40°C1) and for temperature range II -40°C to +50°C/+80°C1) (For temperature range III -40°C to +72°C/+120°C1) see ETA-11/0415).Total safety factor as per ETAG 001 included (γM and γF).
Rebar connection VMU plus
Rebar-Ø [mm] 8 10 12 14 16 20 22 24 25
Drill hole-Ø d0 [mm] 12 14 16 18 20 25 28 32 32Amount of adhesive/100 mm setting depth
[ml] 7,5 9,0 10,6 12,1 13,6 21,2 28,3 42,2 37,6
Installation parameters and amount of adhesive for post-installed rebar connections
Concrete Strength C12/15 C16/20 C20/25 C25/30 C30/37 C35/45 C40/50 C45/55 C50/60
Design value of bond strength fbd,PIR2) [N/mm²] Hammer and pneumatic drilling 1,6 2,0 2,3 2,7 3,0 3,4 3,7 4,0/3,71) 4,3/3,71)
Extract from Permissible Service Conditions of ETA-11/0514 for Post-installed Rebar Connections with Injection System VMU plus
1) The values fbd,PIR are valid for “good” bond conditions according to EN 1992-1-1:2004.2) rebar ø28 and ø32
Z-21.8-2023
For anchor designing, an easy to operate Software is available on request or can be downloaded at www.mkt.de
2019 PR MKT
116... a solid connection
Injection System for cracked concrete, non-cracked concrete and brickwork
Extract from Permissible Service Conditions of European Technical Assessment ETA-13/0909Approved loads for single anchor without in�uence of spacing and edge distance. Butt joint and horizontal joint with adhesive. (Temperature range -40°C to +24°C/+40°C1) – use category dry/dry). Total safety factor as per ETAG included (γM and γF).
1)Max. long term temperature/max. short term temperature2)Installation with perforated sleeve allowed; technical data, see ETA-13/0909 3)Minimum edge distance Cmin,v,ll for shear loads parallel to free edge 4)Minimum edge distance Cmin,v,_l_ for shear loads perpendicular to free edge
Injection system VMU plus, solid base material without perfo sleeve2)
Clay solid brick Mz-DF according EN 771-1, Bulk density ρ: 1,6 kg/dm3, Minimum brick size: 240x115x55 mm (e.g. Unipor)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M10 M12 M16 IG-M6 IG-M8 IG-M10Anchorage depth hef [mm] 80 90 100 100 90 100 100Spacing scr [mm] 240 270 300 300 270 300 300Minimum spacing smin [mm] 120 120 120 120 120 120 120Edge distance ccr [mm] 120 135 150 150 135 150 150Minimum edge distance cmin [mm] 60 60 60 60 60 60 60Approved tension load for compressive strength
fb ≥ 10 N/mm2 appr. N [kN] 1,00 1,00 1,14 1,14 1,00 1,14 1,14fb ≥ 20 N/mm2 appr. N [kN] 1,29 1,57 1,71 1,71 1,57 1,71 1,71fb ≥ 28 N/mm2 appr. N [kN] 1,57 1,71 1,94 1,94 1,71 1,94 1,94
Approved shear load for compressive strength
fb ≥ 10 N/mm2 appr. V [kN] 1,00 1,00 1,00 1,57 1,00 1,00 1,57fb ≥ 20 N/mm2 appr. V [kN] 1,43 1,43 1,43 2,29 1,43 1,43 2,29fb ≥ 28 N/mm2 appr. V [kN] 1,57 1,57 1,57 2,57 1,57 1,57 2,57
Drilling method Hammer drilling
Calcium silicate solid brick KS-NF according EN 771-2, Bulk density ρ: 2,0 kg/dm3, Minimum brick size: 240x115x71 mm (e.g. Wemding)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M10 M12 M16 IG-M6 IG-M8 IG-M10Anchorage depth hef [mm] 80 90 100 100 90 100 100Spacing scr [mm] 240 270 300 300 270 300 300Minimum spacing smin [mm] 120 120 120 120 120 120 120Edge distance ccr [mm] 120 135 150 150 135 150 150Minimum edge distance cmin [mm] 60 60 60 60 60 60 60Approved tension load for compressive strength
fb ≥ 10 N/mm2 appr. N [kN] 1,29 1,29 1,29 1,00 1,29 1,29 1,00fb ≥ 20 N/mm2 appr. N [kN] 1,71 1,71 1,71 1,43 1,71 1,71 1,43fb ≥ 27 N/mm2 appr. N [kN] 2,00 2,00 2,00 1,71 2,00 2,00 1,71
Approved shear load for compressive strength
fb ≥ 10 N/mm2 appr. V [kN] 0,71 0,86 0,71 0,71 0,86 0,71 0,71fb ≥ 20 N/mm2 appr. V [kN] 1,14 1,29 1,14 1,14 1,29 1,14 1,14fb ≥ 27 N/mm2 appr. V [kN] 1,29 1,57 1,29 1,29 1,57 1,29 1,29
Drilling method Hammer drilling
Brickwork of solid lightweight concrete LAC according EN 771-3, Bulk density ρ: 0,6 kg/dm3, Minimum brick size: 300x123x248 mm (e.g. Bisotherm)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M10 M12 M16 IG-M6 IG-M8 IG-M10Anchorage depth hef [mm] 80 90 100 100 90 100 100Spacing scr [mm] 240 270 300 300 270 300 300Minimum spacing smin [mm] 120 120 120 120 120 120 120Edge distance ccr [mm] 120 135 150 150 135 150 150Minimum edge distance cmin [mm] 60 60 60 60 60 60 60Approved tension load for compres-sive strength
fb ≥ 2 N/mm2 appr. N [kN] 0,86 0,86 1,00 0,86 0,86 1,00 0,86
Approved shear load for compres-sive strength
fb ≥ 2 N/mm2 appr. V [kN] 0,86 0,86 0,86 0,86 0,86 0,86 0,86
Drilling method Rotary drilling
Autoclaved aerated concrete AAC6 according EN 771-4, Bulk density ρ: 0,6 kg/dm3, Minimum brick size: 499x240x249 mm (e.g. Porit)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M10 M12 M16 IG-M6 IG-M8 IG-M10Anchorage depth hef [mm] 80 90 100 100 90 100 100Spacing scr [mm] 240 270 300 300 270 300 300Minimum spacing smin [mm] 100 100 100 100 100 100 100Edge distance ccr [mm] 120 135 150 150 135 150 150
Minimum edge distancecmin,N [mm] 75 75 75 75 75 75 75cmin,v,II32) [mm] 75 75 75 75 75 75 75cmin,v,_I_4) [mm] 120 135 150 150 135 150 150
Min. thickness of base material (masonry) hmin [mm] 110 120 130 130 120 130 130Approved tension load for compres-sive strength
fb ≥ 6 N/mm2 appr. N [kN] 0,89 1,43 1,79 2,32 1,43 1,79 2,32
Approved shear load for compres-sive strength
fb ≥ 6 N/mm2 appr. V [kN] 2,14 3,57 3,57 3,57 2,86 3,57 3,57
Drilling method Rotary drilling
Installation parameters in solid base material (without Perfo Sleeve)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M10 M12 M16 IG-M6 IG-M8 IG-M10Drill hole diameter do [mm] 10 12 14 18 12 14 18Depth of drill hole ho [mm] 80 90 100 100 90 100 100Minimum walll thickness hmin [mm] 110 120 130 130 120 130 130
Clearance hole in the �xture df ≤ [mm] 9 12 14 18 7 9 12
Diameter of cleaning brush db ≥ [mm] 12 14 16 20 14 16 20Installation torque Tinst,max [Nm] 2 (14 for clay solid brick Mz-DF)Amount of adhesive per drill hole [ml] 5,2 7,3 9,8 13,6 7,3 9,8 13,6Drill holes per cartridge VMU plus 280 / 300 [pcs.] 46 / 50 33 / 36 24 / 26 18 / 19 33 / 36 24 / 26 18 / 19Drill holes per cartridge VMU plus 345 / 410 [pcs.] 59 / 71 42 / 51 31 / 38 22 / 27 42 / 51 31 / 38 22 / 27
2019 PR MKT
117 ... a solid connection
Chemical Anchors
Ch
emic
al A
nch
ors
Extract from Permissible Service Conditions of European Technical Assessment ETA-13/0909Approved loads for single anchor without in�uence of spacing and edge distance. Butt joint and horizontal joint with adhesive. (Temperature range -40°C to +24°C/+40°C1) – use category dry/dry). Total safety factor as per ETAG included (γM and γF).
1) Max. long term temperature/max. short term temperature 2)For VRk,c : cmin see ETAG 029, Annex C
Injection system VMU plus, perforated brick with Perfo SleeveClay hollow brick Porotherm Homebric according EN 771-1, Bulk density ρ: 0,7 kg/dm3, Minimum brick size: 500x200x299mm (e.g. Wienerberger)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M8 / M10 M12 / M16 IG-M6 IG-M8 / IG-M10Perfo Sleeve VM-SH 12x80 16x85 16x130 20x85 20x130 16x85 20x85Anchorage depth hef [mm] 80 85 130 85 130 85 85Spacing parallel to horizontal joint scr,II [mm] 500 500 500 500 500 500 500Spacing perpendicular to horizontal joint scr,_I_ [mm] 299 299 299 299 299 299 299Minimum spacing smin [mm] 100 100 100 100 100 100 100Edge distance ccr [mm] 100 100 100 120 120 100 120Minimum edge distance cmin2) [mm] 100 100 100 120 120 100 120Approved tension load for compressive strength
fb ≥ 4 N/mm2 appr. N [kN] 0,26 0,26 0,34 0,26 0,34 0,26 0,26fb ≥ 6 N/mm2 appr. N [kN] 0,26 0,26 0,34 0,26 0,34 0,26 0,26fb ≥ 10 N/mm2 appr. N [kN] 0,34 0,34 0,43 0,34 0,43 0,34 0,34
Approved shear load for compressive strength
fb ≥ 4 N/mm2 appr. V [kN] 0,57 0,57 0,57 0,71 0,71 0,57 0,71fb ≥ 6 N/mm2 appr. V [kN] 0,71 0,71 0,71 0,86 0,86 0,71 0,86fb ≥ 10 N/mm2 appr. V [kN] 0,86 0,86 1,00 1,14 1,14 0,86 1,14
Clay hollow brick HLz-16-DF according EN 771-1, Bulk density ρ: 0,8 kg/dm3, Minimum brick size: 497x240x238 mm (e.g. Unipor)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M8 / M10 M12 / M16 IG-M6 IG-M8 / IG-M10Perfo Sleeve VM-SH 12x80 16x85 16x130 20x85 20x130 20x200 16x85 20x85Anchorage depth hef [mm] 80 85 130 85 130 200 85 85Spacing parallel to horizontal joint scr,II [mm] 497 497 497 497 497 497 497 497Spacing perpendicular to horizontal joint scr,_I_ [mm] 238 238 238 238 238 238 238 238Minimum spacing smin [mm] 100 100 100 100 100 100 100 100Edge distance ccr [mm] 100 100 100 120 120 120 100 120Minimum edge distance cmin2) [mm] 100 100 100 120 120 120 100 120
Approved tension load for compressive strength
fb ≥ 6 N/mm2 appr. N [kN] 0,71 0,71 1,00 0,71 1,00 1,00 0,71 0,71fb ≥ 8 N/mm2 appr. N [kN] 0,86 0,86 1,29 0,86 1,29 1,29 0,86 0,86fb ≥ 12 N/mm2 appr. N [kN] 1,00 1,00 1,43 1,00 1,43 1,43 1,00 1,00fb ≥ 14 N/mm2 appr. N [kN] 1,14 1,14 1,57 1,14 1,57 1,57 1,14 1,14
Approved shear load for compressive strength
fb ≥ 6 N/mm2 appr. V [kN] 0,71 1,29 1,29 1,43 1,71 1,71 1,29 1,43fb ≥ 8 N/mm2 appr. V [kN] 0,86 1,57 1,57 1,71 2,00 2,00 1,57 1,71fb ≥ 12 N/mm2 appr. V [kN] 1,14 1,86 1,86 2,00 2,57 2,57 1,86 2,00fb ≥ 14 N/mm2 appr. V [kN] 1,14 1,86 1,86 2,00 2,57 2,57 1,86 2,00
Clay hollow brick Doppio Uni according EN 771-1, Bulk density ρ: 0,9 kg/dm3, Minimum brick size: 250x120x120 mm (e.g. Wienerberger)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M8 / M10 M12 / M16 IG-M6 IG-M8 / IG-M10Perfo Sleeve VM-SH 12x80 16x85 16x130 20x85 20x130 20x200 16x85 20x85Anchorage depth hef [mm] 80 85 130 85 130 200 85 85Spacing parallel to horizontal joint scr,II [mm] 250 250 250 250 250 250 250 250Spacing perpendicular to horizontal joint scr,_I_ [mm] 120 120 120 120 120 120 120 120
Min. spacing parallel to horizontal joint smin,II [mm] 100 100 100 100 100 100 100 100
Min. Perpendicular to horizontal joint spacing smin,_I_ [mm] 120 120 120 120 120 120 120 120
Edge distance ccr [mm] 100 100 100 120 120 120 100 120Minimum edge distance cmin2) [mm] 60 60 60 60 60 60 60 60
Approved tension load for compressive strength
fb ≥ 10 N/mm2 appr. N [kN] 0,17 0,17 0,17 0,17 0,17 0,17 0,17 0,17fb ≥ 16 N/mm2 appr. N [kN] 0,21 0,21 0,21 0,21 0,21 0,21 0,21 0,21fb ≥ 20 N/mm2 appr. N [kN] 0,26 0,26 0,26 0,26 0,26 0,26 0,26 0,26fb ≥ 28 N/mm2 appr. N [kN] 0,34 0,34 0,34 0,34 0,34 0,34 0,34 0,34
Approved shear load for compressive strength
fb ≥ 10 N/mm2 appr. V [kN] 0,43 0,43 0,43 0,43 0,43 0,43 0,43 0,43fb ≥ 16 N/mm2 appr. V [kN] 0,57 0,57 0,57 0,57 0,57 0,57 0,57 0,57fb ≥ 20 N/mm2 appr. V [kN] 0,57 0,57 0,57 0,57 0,57 0,57 0,57 0,57fb ≥ 28 N/mm2 appr. V [kN] 0,71 0,71 0,71 0,71 0,71 0,71 0,71 0,71
Calcium silicate hollow brick KSL-3DF according EN 771-2, Bulk density ρ: 1,4 kg/dm3, Minimum brick size: 240x175x113 mm (e.g. Wemding)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M8 / M10 M12 / M16 IG-M6 IG-M8 / IG-M10Perfo Sleeve VM-SH 12x80 16x85 16x130 20x85 20x130 20x200 16x85 20x85Anchorage depth hef [mm] 80 85 130 85 130 200 85 85Spacing parallel to horizontal joint scr,II [mm] 240 240 240 240 240 240 240 240Spacing perpendicular to horizontal joint scr,_I_ [mm] 120 120 120 120 120 120 120 120Minimum spacing smin [mm] 120 120 120 120 120 120 120 120Edge distance ccr [mm] 100 100 100 120 120 120 100 120Minimum edge distance cmin [mm] 60 60 60 60 60 60 60 60Approved tension load for compressive strength
fb ≥ 8 N/mm2 appr. N [kN] 0,43 0,43 0,43 1,29 1,29 1,29 0,43 1,29fb ≥ 12 N/mm2 appr. N [kN] 0,57 0,57 0,71 1,71 1,71 1,71 0,57 1,71fb ≥ 14 N/mm2 appr. N [kN] 0,71 0,71 0,71 1,86 1,86 1,86 0,71 1,86
Approved shear load for compressive strength
fb ≥ 8 N/mm2 appr. V [kN] 0,71 1,14 1,14 1,14 1,14 1,14 1,14 1,14fb ≥ 12 N/mm2 appr. V [kN] 0,86 1,29 1,29 1,29 1,29 1,29 1,29 1,29fb ≥ 14 N/mm2 appr. V [kN] 1,00 1,71 1,71 1,71 1,71 1,71 1,71 1,71
2019 PR MKT
118... a solid connection
Injection System for cracked concrete, non-cracked concrete and brickwork
Installation
Nm
Tinst+20 °C
45 min.
1)Max. long term temperature/max. short term temperature2)For VRk,c : cmin see ETAG 029, Annex C
Extract from Permissible Service Conditions of European Technical Assessment ETA-13/0909Approved loads for single anchor without in�uence of spacing and edge distance. Butt joint and horizontal joint with adhesive. (Temperature range -40°C to +24°C/+40°C1) – use category dry/dry). Total safety factor as per ETAG included (γM and γF).
Injection system VMU plus, perforated brick with Perfo SleeveCalcium silicate hollow brick KSL-12DF according EN 771-2, Bulk density ρ: 1,4 kg/dm3, Minimum brick size: 498x175x238 mm (e.g. Wemding)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M8 / M10 M12 / M16 IG-M6 IG-M8 / IG-M10Perfo Sleeve VM-SH 12x80 16x85 16x130 20x85 20x130 16x85 20x85Anchorage depth hef [mm] 80 85 130 85 130 85 85Spacing parallel to horizontal joint scr,II [mm] 498 498 498 498 498 498 498Spacing perpendicular to horizontal joint scr,_I_ [mm] 238 238 238 238 238 238 238Minimum spacing smin [mm] 120 120 120 120 120 120 120Edge distance ccr [mm] 100 100 100 120 120 100 120Minimum edge distance cmin2) [mm] 100 100 100 120 120 100 120Min. thickness of base material (masonry) hmin [mm] 115 115 175 115 175 115 115
Approved tension load for compressive strength
fb ≥ 10 N/mm2 appr. N [kN] 0,17 0,17 0,71 0,43 0,71 0,17 0,43fb ≥ 12 N/mm2 appr. N [kN] 0,21 0,21 0,86 0,43 0,86 0,21 0,43fb ≥ 16 N/mm2 appr. N [kN] 0,26 0,26 1,14 0,57 1,14 0,26 0,57
Approved shear load for compressive strength
fb ≥ 10 N/mm2 appr. V [kN] 0,71 1,57 1,57 1,57 1,57 1,57 1,57fb ≥ 12 N/mm2 appr. V [kN] 0,86 1,86 1,86 1,86 1,86 1,86 1,86fb ≥ 16 N/mm2 appr. V [kN] 1,00 2,29 2,29 2,29 2,29 2,29 2,29
Hollow lightweight concrete Bloc creux B40 according EN 771-3, Bulk density ρ: 0,8 kg/dm3, Minimum brick size: 494x200x190 mm (e.g. Sepa)Threaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M8 / M10 M12 / M16 IG-M6 IG-M8 / IG-M10Perfo Sleeve VM-SH 12x80 16x85 16x130 20x85 20x130 16x85 20x85Anchorage depth hef [mm] 80 85 130 85 130 85 85Spacing parallel to horizontal joint scr,II [mm] 494 494 494 494 494 494 494Spacing perpendicular to horizontal joint scr,_I_ [mm] 190 190 190 190 190 190 190Minimum spacing smin [mm] 100 100 100 100 100 100 100Edge distance ccr [mm] 100 100 100 120 120 100 120Minimum edge distance cmin2) [mm] 100 100 100 120 120 100 120Min. thickness of base material (masonry) hmin [mm] 115 115 175 115 175 115 115Approved tension load for compressive strength
fb ≥ 4 N/mm2 appr. N [kN] 0,34 0,34 0,34 0,34 0,34 0,34 0,34
Approved shear load for compressive strength
fb ≥ 4 N/mm2 appr. V [kN] 0,86 0,86 0,86 0,86 0,86 0,86 0,86
Installation parameter in solid brickwork with a Perfo SleeveThreaded Stud: Steel: ≥ FKL. 5.8, A4, HCR: ≥ FKL 70 M8 M8 / M10 M12 / M16 IG-M6 IG-M8 / IG-M10Perfo Sleeve VM-SH 12x80 16x85 16x130 20x85 20x130 20x200 16x85 20x85Drill hole diameter do [mm] 12 16 16 20 20 20 16 20Depth of drill hole ho [mm] 85 90 135 90 135 205 90 90Minimum wall thickness hmin [mm] 115 115 175 115 175 240 115 115Clearance hole in the �xture df ≤ [mm] 9 9 / 12 9 / 12 14 / 18 14 / 18 14 / 18 7 9 / 12Diameter of cleaning brush db ≥ [mm] 14 18 18 22 22 22 18 22Installation torque Tinst,max [Nm] 2Amount of adhesive per drill hole [ml] 11,2 24,9 38,0 41,1 62,9 96,7 24,9 41,1Drill holes per cartridge VMU plus 280 / 300 [pcs.] 21 / 23 9 / 10 6 / 6 5 / 6 3 / 4 2 / 2 9 / 10 5 / 6Drill holes per cartridge VMU plus 345 / 410 [pcs.] 27 / 33 12 / 14 8 / 9 7 / 9 4 / 5 3 / 3 12 / 14 7 / 9Drilling method Rotary drilling
90°
2019 PR MKT