INJECTION MOLDED TEE 4 - 12 DIAMETER PART # PIPE SIZE A ... · 4 in 7.4 in 5.5 in 6.1 in (100 mm)...
Transcript of INJECTION MOLDED TEE 4 - 12 DIAMETER PART # PIPE SIZE A ... · 4 in 7.4 in 5.5 in 6.1 in (100 mm)...
4 in 7.4 in 3.7 in
(100 mm) (187 mm) (93 mm)
4 in 7.4 in 3.7 in
(100 mm) (187 mm) (93 mm)
6 in 10.5 in 5.2 in
(150 mm) (266 mm) (133 mm)
6 in 10.5 in 5.2 in
(150 mm) (266 mm) (133 mm)
8 in 13.8 in 6.9 in
(200 mm) (350 mm) (175 mm)
8 in 13.8 in 6.9 in
(200 mm) (350 mm) (175 mm)
10 in 17.9 in 8.9 in
(250 mm) (454 mm) (227 mm)
10 in 17.9 in 8.9 in
(250 mm) (454 mm) (227 mm)
12 in 22.5 in 11.3 in
(300 mm) (572 mm) (286 mm)
12 in 22.5 in 11.3 in
(300 mm) (572 mm) (286 mm)
NOTE: FITTINGS WHOSE PART NUMBERS END WITH "WT" HAVE WATER TIGHT BELL CONNECTIONS. WATER TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
FITTINGS WHOSE PART NUMBERS END WITH "ST" HAVE SOIL TIGHT BELL CONNECTIONS. SOIL TIGHT BELLS HAVE MOLDED CLEATS AND REQUIRE NO GASKET TO MAKE CONNECTION TO DUAL WALL PIPE. DRAWING #: 3000
DRAWN BY: JCB 07.28.06APPROVED BY: JCB 06.26.07
NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: NJP 06.15.07
1063WT
1264ST
1264WT
INJECTION MOLDED TEE
PIPE SIZE A JOINTPART #
4" - 12" DIAMETER
B
0460ST
0862WT
0661WT
0460WT
1063ST
0862ST
0661ST
ST
WT
ST
WT
ST
WT
ST
WT
ST
WT
6 × 4 in 7.4 in 4.4 in
(150 × 100 mm) (187 mm) (111 mm)
6 × 4 in 7.4 in 4.4 in
(150 × 100 mm) (187 mm) (111 mm)
10 × 8 in 17.9 in 9.9 in
(250 × 200 mm) (454 mm) (252 mm)
10 × 8 in 17.9 in 9.9 in
(250 × 200 mm) (454 mm) (252 mm)
12 × 8 in 22.5 in 13.6 in
(300 × 200 mm) (572 mm) (346 mm)
NOTE:
FITTINGS WHOSE PART NUMBERS END WITH "WT"
HAVE WATER TIGHT BELL CONNECTIONS. WATER
TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND
REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE
TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
FITTINGS WHOSE PART NUMBERS END WITH "ST"
HAVE SOIL TIGHT BELL CONNECTIONS. SOIL TIGHT
BELLS HAVE MOLDED CLEATS AND REQUIRE NO
GASKET TO MAKE CONNECTION TO DUAL WALL PIPE.
DRAWING #: 3010
DRAWN BY: JCB 04.24.07
APPROVED BY:NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: TJR 10.17.07
INJECTION MOLDED REDUCING TEE
PIPE SIZE A JOINTPART #
6" x 4" - 10"×8" - 12"×8" DIAMETER
B
1062ST
1062WT
1262WT
ST
WT
WT
0660ST ST
0660WT WT
4 in 7.4 in 5.5 in 6.1 in
(100 mm) (187 mm) (140 mm) (154 mm)
4 in 7.4 in 5.5 in 6.1 in
(100 mm) (187 mm) (140 mm) (154 mm)
6 in 10.5 in 8.0 in 8.7 in
(150 mm) (266 mm) (202 mm) (220 mm)
6 in 10.5 in 8.0 in 8.7 in
(150 mm) (266 mm) (202 mm) (220 mm)
8 in 13.8 in 10.6 in 11.4 in
(200 mm) (350 mm) (268 mm) (290 mm)
8 in 13.8 in 10.6 in 11.4 in
(200 mm) (350 mm) (268 mm) (290 mm)
10 in 17.9 in 13.3 in 14.4 in
(250 mm) (454 mm) (338 mm) (367 mm)
10 in 17.9 in 13.3 in 14.4 in
(250 mm) (454 mm) (338 mm) (367 mm)
12 in 22.5 in 16.5 in 18.1 in
(300 mm) (572 mm) (419 mm) (461 mm)
12 in 22.5 in 16.5 in 18.1 in
(300 mm) (572 mm) (419 mm) (461 mm)
NOTE: FITTINGS WHOSE PART NUMBERS END WITH "WT" HAVE WATER TIGHT BELL CONNECTIONS. WATER TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
FITTINGS WHOSE PART NUMBERS END WITH "ST" HAVE SOIL TIGHT BELL CONNECTIONS. SOIL TIGHT BELLS HAVE MOLDED CLEATS AND REQUIRE NO GASKET TO MAKE CONNECTION TO DUAL WALL PIPE. DRAWING #: 3100
DRAWN BY: JCB 07.28.06APPROVED BY:
NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: TJR 9/26/2016
WT
ST
WT
ST
WT
ST
WT
ST
C
WT
ST
0480ST
0882WT
0681WT
0480WT
1083ST
0882ST
0681ST
1083WT
1284ST
1284WT
INJECTION MOLDED 45° WYE
PIPE SIZE A JOINTPART #
4" - 12" DIAMETER
B
6 × 4 in 9.3 in 8.3 in 4.8 in
(150 × 100 mm) (235 mm) (210 mm) (123 mm)
6 × 4 in 9.3 in 8.3 in 4.8 in
(150 × 100 mm) (235 mm) (210 mm) (123 mm)
8 × 4 in 10.7 in 10.0 in 9.2 in
(200 × 100 mm) (271 mm) (254 mm) (233 mm)
8 × 4 in 10.7 in 10.0 in 9.2 in
(200 × 100 mm) (271 mm) (254 mm) (233 mm)
8 × 6 in 12.6 in 11.3 in 10.8 in
(200 × 150 mm) (320 mm) (286 mm) (275 mm)
8 × 6 in 12.6 in 11.3 in 10.8 in
(200 × 150 mm) (320 mm) (286 mm) (275 mm)
10 × 8 in 17.9 in 14.3 in 13.9 in
(250 × 200 mm) (454 mm) (362 mm) (354 mm)
10 × 8 in 17.9 in 14.3 in 13.9 in
(250 × 200 mm) (455 mm) (362 mm) (354 mm)
12 × 6 in 17.1 in 15.8 in 14.5 in
(300 × 150 mm) (435 mm) (400 mm) (369 mm)
12 × 8 in 22.5 in 18.7 in 18.1 in
(300 × 200 mm) (572 mm) (474 mm) (461 mm)
NOTE: FITTINGS WHOSE PART NUMBERS END WITH "WT" HAVE WATER TIGHT BELL CONNECTIONS. WATER TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
FITTINGS WHOSE PART NUMBERS END WITH "ST" HAVE SOIL TIGHT BELL CONNECTIONS. SOIL TIGHT BELLS HAVE MOLDED CLEATS AND REQUIRE NO GASKET TO MAKE CONNECTION TO DUAL WALL PIPE.
DRAWING #: 3110DRAWN BY: JCB 04.24.07
APPROVED BY:NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: TJR 03.08.13
1082WT
1282WT
1281WT
WT
WT
INJECTION MOLDED 45° REDUCING WYE
PIPE SIZE A JOINTPART #
6" x 4" - 8" x 4" - 8" x 6" -10"×8" - 12" x 6" - 12"×8" DIAMETER
B C
WT
0680ST ST
0680WT WT
0880ST ST
1082ST ST
0880WT WT
0881ST ST
0881WT WT
4 in 1.3 in
(100 mm) (33 mm)
4 in 1.3 in
(100 mm) (33 mm)
6 in 1.8 in
(150 mm) (46 mm)
6 in 1.8 in
(150 mm) (46 mm)
8 in 2.4 in
(200 mm) (60 mm)
8 in 2.4 in
(200 mm) (60 mm)
10 in 3.4 in
(250 mm) (87 mm)
10 in 3.4 in
(250 mm) (87 mm)
12 in 4.4 in
(300 mm) (112 mm)
12 in 4.4 in
(300 mm) (112 mm)
NOTE: FITTINGS WHOSE PART NUMBERS END WITH "WT" HAVE WATER TIGHT BELL CONNECTIONS. WATER TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
FITTINGS WHOSE PART NUMBERS END WITH "ST" HAVE SOIL TIGHT BELL CONNECTIONS. SOIL TIGHT BELLS HAVE MOLDED CLEATS AND REQUIRE NO GASKET TO MAKE CONNECTION TO DUAL WALL PIPE. DRAWING #: 3200
DRAWN BY: JCB 07.31.06APPROVED BY:
NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: NJP 06.15.07
1094WT
1294ST
1294WT
INJECTION MOLDED 45° BEND
PIPE SIZE A JOINTPART #
4" - 12" DIAMETER
0494ST
0894WT
0694WT
0494WT
1094ST
0894ST
0694ST
ST
WT
ST
WT
ST
WT
ST
WT
ST
WT
4 in 3.7 in
(100 mm) (93 mm)
4 in 3.7 in
(100 mm) (93 mm)
6 in 5.2 in
(150 mm) (133 mm)
6 in 5.2 in
(150 mm) (133 mm)
8 in 6.9 in
(200 mm) (175 mm)
8 in 6.9 in
(200 mm) (175 mm)
10 in 8.9 in
(250 mm) (227 mm)
10 in 8.9 in
(250 mm) (227 mm)
12 in 11.3 in
(300 mm) (286 mm)
12 in 11.3 in
(300 mm) (286 mm)
NOTE: FITTINGS WHOSE PART NUMBERS END WITH "WT" HAVE WATER TIGHT BELL CONNECTIONS. WATER TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
FITTINGS WHOSE PART NUMBERS END WITH "ST" HAVE SOIL TIGHT BELL CONNECTIONS. SOIL TIGHT BELLS HAVE MOLDED CLEATS AND REQUIRE NO GASKET TO MAKE CONNECTION TO DUAL WALL PIPE. DRAWING #: 3300
DRAWN BY: JCB 07.31.06APPROVED BY:
NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: NJP 06.15.07
ST
WT
ST
WT
ST
WT
ST
WT
ST
WT
0899WT
0699WT
0499WT
1099ST
0899ST
0699ST
1099WT
1299ST
1299WT
INJECTION MOLDED 90° BEND
PIPE SIZE A JOINTPART #
4" - 12" DIAMETER
0499ST
6 × 4 in 5.6 in 4.3 in 6.9 in
(150 × 100 mm) (142 mm) (108 mm) (176 mm)
8 × 4 in 5.7 in 4.3 in 9.2 in
(200 × 100 mm) (145 mm) (108 mm) (233 mm)
8 × 6 in 8.0 in 5.3 in 9.2 in
(200 × 150 mm) (204 mm) (133 mm) (233 mm)
NOTE: FITTINGS WHOSE PART NUMBERS END WITH "WT" HAVE WATER TIGHT BELL CONNECTIONS. WATER TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
DRAWING #: 3400DRAWN BY: JCB 07.31.06
APPROVED BY:NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: NJP 06.15.07
WT
WT
WT
0874WT
0876WT
0674WT
INJECTION MOLDED BELL/SPIGOT REDUCER
PIPE SIZE A JOINTPART # B C
6 × 4 in 5.6 in 6.6 in 7.9 in
(150 × 100 mm) (142 mm) (167 mm) (201 mm)
8 × 4 in 5.7 in 6.6 in 10.4 in
(200 × 100 mm) (145 mm) (167 mm) (263 mm)
8 × 6 in 8.0 in 7.7 in 10.4 in
(200 × 150 mm) (204 mm) (196 mm) (263 mm)
10 × 8 in 10.3 in 9.9 in 12.9 in
(200 × 100 mm) (262 mm) (250 mm) (327 mm)
12 × 8 in 10.4 in 11.2 in 16.3 in
(200 × 150 mm) (265 mm) (285 mm) (413 mm)
12 × 10 in 13.0 in 12.3 in 16.3 in
(200 × 100 mm) (329 mm) (313 mm) (413 mm)
NOTE: FITTINGS WHOSE PART NUMBERS END WITH "WT" HAVE WATER TIGHT BELL CONNECTIONS. WATER TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
DRAWING #: 3500DRAWN BY: JCB 07.31.06
APPROVED BY:NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: NJP 06.15.07
INJECTION MOLDED REDUCING BELL/BELL COUPLER
PART # PIPE SIZE A B C JOINT
WT
WT
WT
1218WT
1210WT
1018WT
0816WT WT
0614WT WT
0814WT WT
4 × 4 in 2.3 in 4.7 in 5.6 in
(100 × 100 mm) (59 mm) (119 mm) (141 mm)
6 × 6 in 3.5 in 6.9 in 7.9 in
(150 × 150 mm) (88 mm) (176 mm) (201 mm)
8 × 8 in 4.3 in 8.6 in 10.4 in
(200 × 200 mm) (108 mm) (217 mm) (263 mm)
10 × 10 in 5.5 in 11.0 in 12.9 in
(250 × 250 mm) (140 mm) (279 mm) (326 mm)
NOTE: FITTINGS WHOSE PART NUMBERS END WITH "WT" HAVE WATER TIGHT BELL CONNECTIONS. WATER TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
DRAWING #: 3600DRAWN BY: JCB 03.28.07
APPROVED BY:NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: TJR 10.17.07
INJECTION MOLDED BELL/BELL COUPLER
PIPE SIZE A JOINTPART # B
1013WT WT
C
0413WT
0613WT
0813WT
WT
WT
WT
8 × 4 in 16.0 in 8.1 in 9.4 in 6.0 in
(200 × 100 mm) (406 mm) (206 mm) (239 mm) (151 mm)
8 × 4 in 16.0 in 8.1 in 9.4 in 6.0 in
(200 × 100 mm) (406 mm) (206 mm) (239 mm) (151 mm)
8 × 6 in 21.8 in 10.0 in 13.8 in 6.8 in
(200 × 150 mm) (554 mm) (255 mm) (349 mm) (171 mm)
8 × 6 in 21.8 in 10.0 in 13.8 in 6.8 in
(200 × 150 mm) (554 mm) (255 mm) (349 mm) (171 mm)
10 × 6 in 22.5 in 14.1 in 12.5 in 10.9 in
(250 × 150 mm) (572 mm) (359 mm) (317 mm) (276 mm)
10 × 6 in 22.5 in 14.1 in 12.5 in 10.9 in
(250 × 150 mm) (572 mm) (359 mm) (317 mm) (276 mm)
12 × 6 in 24.5 in 14.1 in 11.8 in 10.9 in
(300 × 150 mm) (622 mm) (359 mm) (299 mm) (276 mm)
NOTE: FITTINGS WHOSE PART NUMBERS END WITH "WT" HAVE WATER TIGHT BELL CONNECTIONS. WATER TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
DRAWING #: 3700DRAWN BY: JCB 03.28.07
APPROVED BY:NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: TJR 10.17.07
INJECTION MOLDED SWEEPING TEE
PIPE SIZE A JOINTPART #
8"×4" - 12"×6" DIAMETER
B
1236WT WT
DC
0863WT
0836WT
1036WT
WT
WT
WT
1036ST ST
0863ST ST
0836ST ST
4 in 2.7 in 5.1 in
(100 mm) (67 mm) (131 mm)
6 in 3.9 in 7.3 in
(150 mm) (98 mm) (185 mm)
NOTE:
FITTINGS WHOSE PART NUMBERS END WITH "WT"
HAVE WATER TIGHT BELL CONNECTIONS. WATER
TIGHT BELLS ARE SHOWN HERE IN THIS DRAWING AND
REQUIRE GASKETS TO BE FITTED TO DUAL WALL PIPE
TO FORM A WATER TIGHT JOINT. (GASKETS INCLUDED)
DRAWING #: 3800
DRAWN BY: JCB 03.28.07
APPROVED BY:NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS: NJP 06.15.07
INJECTION MOLDED END CAP
PIPE SIZE A JOINTPART # B
0432WT
0632WT
WT
WT
4 in 2.2 in
(100 mm) (56 mm)
6 in 3.3 in
(150 mm) (84 mm)
8 in 4.0 in
(200 mm) (102 mm)
10 in 5.0 in
(250 mm) (127 mm)
12 in 6.4 in
(300 mm) (163 mm)
NOTE: DIMENSION IS NOT OVERALL BELL LENGTH AND IS TO BE ADDED TO RESPECTIVE FITTING'S INDICATED LAY LENGTH
DRAWING #: 3900DRAWN BY: TJR 6/10/2009
APPROVED BY:NOTE: ALL FITTINGS DIMENSIONS ARE FOR REFERENCE ONLY REVISIONS:
(REFERENCE CHART)
PIPE SIZEBELL*
LENGTH
INJECTION MOLDED BELL LENGTH