Infrastructure Services for Physical Data
description
Transcript of Infrastructure Services for Physical Data
Infrastructure Services for Physical Data
Stephen Dawson-Haggerty
Cyber / Physical Building
BMS
Cyber Physical Building
Ligh
tTr
ansp
ortProcess
Loads
Occupant Demand
Legacy Instrumentation & Control Interfaces
Pervasive Sensing
Activity/UsageStreams
BIM
PIB
Activity Models
Multi-Objective Model-Driven Control
Building IntegratedOperating System
External
HVAC
Elec
tric
al
Faul
t, Att
ack,
Ano
mal
y De
tect
&M
anag
emen
t
Control Plan and Schedule
Physical Models
Human-Building
Interface
Open Platform for Building Applications
3
http://new.openbms.org/
InternetCell phone
sMAP Gateway
sMAP
Modbus RS-485
sMAP
sMAP Gateway
EBHTTP / IPv6 / 6LowPANWireless Mesh Network
sMAP
sMAP
sMAP
sMAP
Edge Router
Temperature/PAR/TSR
Vibration / Humidity
AC plug meter
Light switch
Dent
circ
uit m
eter
Prox
y Se
rver
EBHT
TP
Tran
slatio
n
California ISO sMAP Gateway
sMAP Resources Applications
Google PowerMeter
Weather
sMAP
Every Building
Database
Live System with Big DataImporting old data: 150k points/sec Continuous write load: 300-500pts/sec
~6 billion points from just a few buildings
1k points/building x 1 reading/30 seconds forever!
Building Information
Load TreeClimate Plant
Vibration
TemperatureHumidity
Pressure
CT: Mains Power Monitoring
Panel Level Power Monitoring
ACme: Plug Load Energy Monitor and Controller
Panel 1 Panel 2
A
B
A
B
Panel 1 Panel 2
A
B
A
B
1591317212529333741
371115192327313539
A1591317212529333741
371115192327313539
1591317212529333741
371115192327313539
A26101418222630343842
481216202428323640
B26101418222630343842
481216202428323640
26101418222630343842
481216202428323640
B1591317212529333741
371115192327313539
A1591317212529333741
371115192327313539
1591317212529333741
371115192327313539
A26101418222630343842
481216202428323640
B26101418222630343842
481216202428323640
26101418222630343842
481216202428323640
B
Operations and Environment
slicr: Tags Generate Multiple Views
January 9, 2012 Local Winter Retreat 2012
[ { tag : "Metadata/SourceName", restrict: "has Metadata/Extra/EndUse"},
{ tag: "Metadata/Extra/EndUse"},
{ tag: "Metadata/Extra/Category", defaultSubStream: "Properties/UnitofMeasure = 'mW'", seriesLabel:["Metadata/Location/Room", "Metadata/Extra/Load"]}, { tag: "Metadata/Extra/ProductType", defaultSubStream: "Properties/UnitofMeasure = 'mW'", seriesLabel:["Metadata/Location/Room", "Metadata/Extra/Load"]}, { tag: "Metadata/Instrument/PartNumber", defaultSubStream: "Properties/UnitofMeasure = 'mW'", seriesLabel:["Metadata/Instrument/PartNumber", "Metadata/Location/Room", "Metadata/Extra/Load”]}, "Properties/UnitofMeasure”]
7
• Model-Predictive HVAC Controls• Occupant-responsive spaces• Privacy-preserving database
In 380 Soda Hall: Wozniak Lounge