INDUCTIVE SENSORS · Nominal sensing distance 2 mm 4 mm Operating distance 1,62 mm 3,24 mm Mounting...
Transcript of INDUCTIVE SENSORS · Nominal sensing distance 2 mm 4 mm Operating distance 1,62 mm 3,24 mm Mounting...
INDUCTIVE SENSORS
Standard Line
Back Light
NO - NPN PS2-12GI50-E Tras. Iluminada PS4-12GI50-E Tras. Iluminada
NO - PNP PS2-12GI50-E2 Tras. Iluminada PS4-12GI50-E2 Tras. Iluminada
Drawing 21 22
Nominal sensing distance 2 mm 4 mm
Operating distance 1,62 mm 3,24 mm
Mounting built-in not built-in
Hysteresis 5% 5%
Repeatability < 0,01mm < 0,01mm
Standard target 12 x 12 mm 12 x 12 mm
Operating voltage range 10 to 30 Vdc 10 to 30 Vdc
Ripple ± 10% ± 10%
Max. switching current 200 mA 200 mA
Current consumption 10 mA 10 mA
Output voltage drop 2 V 2 V
Max. switching frequency 800 Hz 400 Hz
Protection circuit short-circuit / inversion short-circuit / inversion
Output indication back light back light
Operating temperature range -25 °C to + 70 °C -25 °C to + 70 °C
Protection class IP 67, IP69K IP 67, IP69K
Weight 110 g 110 g
Connection 2 m PVC 3 wires 0.16 mm2 2 m PVC 3 wires 0.16 mm2
Cable options 6 m PVC or 2 m PU 6 m PVC or 2 m PU
Tube length 50, optional 70 mm 50, optional 70 mm
Housing options GX, GT, GP GX, GT, GP
M12
Code Housing
GI nickel plated brass and back light
GX stainless steel and back light
GT PTFE plated brass and back light
GP thermoplastic polyester with fiberglass and back light
50 50 mm tube (standard)
70 70 mm tube (opcional)
Output Configuration
Mechanical Dimensions
BN - brown BU - blueBK - black
10 - 30Vdc
NPN-E BN(1)
BK(4)
BU(3) -
+
NO
Ø
8
Dwg. 22
Cable Color
Dwg. 21
PNP-E2BN(1)
BU(3)
BK(4) 10 - 30Vdc
-
+
NO
FEATURES
Standard Line/ Back Light
back light
3-WireDC
Cable Connection
back light
NO + NC - NPN PS2-12GI60-A Tras. Iluminada PS4-12GI60-A Tras. Iluminada
NO + NC - PNP PS2-12GI60-A2 Tras. Iluminada PS4-12GI60-A2 Tras. Iluminada
25 26
2 mm 4 mm
1,62 mm 3,24 mm
built-in not built-in
5% 5%
< 0,01mm < 0,01mm
12 x 12 mm 12 x 12 mm
10 to 30 Vdc 10 to 30 Vdc
± 10% ± 10%
200 mA 200 mA
10 mA 10 mA
2 V 2 V
800 Hz 400 Hz
short-circuit / inversion short-circuit / inversion
-25 °C to + 70 °C -25 °C to + 70 °C
IP 67, IP69K IP 67, IP69K
110 g 110 g
2m PVC 4-wires 0.16 mm2
2 m PVC 4 wires 0.16 mm2
6 m PVC or 2 m PU 6 m PVC or 2 m PU
60, optional 70 mm 60, optional 70 mm
GX, GT, GP GX, GT, GP
10 - 30Vdc
BN(1)NPN-A
NO+NC
WH(2)
BK(4)
BU(3) -
+
Dwg. 26Dwg. 25
PNP-A2
NO+NC
BN(1)
BK(4)
WH(2)
BU(3)
10 - 30Vdc
+
-
Output ConfigurationBN - brown BU - blueBK - black
Cable Color
Mechanical Dimensions
Code Housing
GI nickel plated brass and back light
GX stainless steel and back light
GT PTFE plated brass and back light
GP thermoplastic polyester with fiberglass and back light
60 60 mm tube (standard)
70 70 mm tube (opcional)
FEATURES
M124-Wire
DCCable Connection
Nominal sensing distance
Operating distance
Mounting
Hysteresis
Repeatability
Standard target
Operating voltage range
Ripple
Max. switching current
Current consumption
Output voltage drop
Max. switching frequency
Output indication
Operating temperature range
Protection class
Weight
Connection
Housing options
Standard Line/ Back Light
Drawing
Protection circuit
Cable options
Tube length
back light back light
back light
back light
NO - NPN PS5-18GI50-E Tras. Iluminada PS8-18GI50-E Tras. Iluminada
NO - PNP PS5-18GI50-E2 Tras. Iluminada PS8-18GI50-E2 Tras. Iluminada
39 40
5 mm 8 mm
4,05 mm 6,48 mm
built-in not built-in
5% 5%
< 0,01mm < 0,01mm
18 x 18 mm 24 x 24 mm
10 to 30 Vdc 10 to 30 Vdc
± 10% ± 10%
200 mA 200 mA
10 mA 10 mA
2 V 2 V
500Hz 200Hz
short circuit / inversion short circuit / inversion
-25 °C to + 70 °C -25 °C to + 70 °C
IP 67, IP69K IP 67, IP69K
150 g 150 g
2 m PVC 3 wires 0.31 mm2
2 m PVC 3 wires 0.31 mm2
6 m PVC or 2 m PU 6 m PVC or 2 m PU
50, optional 70 mm 50, optional 70 mm
GX, GT, GP GX, GT, GP
BN - brownBU - blueBK - black
10 - 30Vdc
NPN-E BN(1)
BK(4)
BU(3) -
+
NO
Ø
Dwg. 40
Dwg. 39
PNP-E2BN(1)
BU(3)
BK(4) 10 - 30Vdc
-
+
NO
Output Configuration
Mechanical Dimensions
Cable Color
FEATURES
Code Housing
GI nickel plated brass and back light
GX stainless steel and back light
GT PTFE plated brass and back light
GP thermoplastic polyester with fiberglass and back light
50 50 mm tube (standard)
70 70 mm tube (opcional)
Nominal sensing distance
Operating distance
Mounting
Hysteresis
Repeatability
Standard target
Operating voltage range
Ripple
Max. switching current
Current consumption
Output voltage drop
Max. switching frequency
Output indication
Operating temperature range
Protection class
Weight
Connection
Housing options
M183-Wire
DCCable Connection
Standard Line/ Back Light
Drawing
Protection circuit
Cable options
Tube length
back light back light
back light
back light
NO + NC - NPN PS5-18GI50-A Tras. Iluminada PS8-18GI50-A Tras. Iluminada
NO + NC - PNP PS5-18GI50-A2 Tras. Iluminada PS8-18GI50-A2 Tras. Iluminada
43 44
5 mm 8 mm
4,05 mm 6,48 mm
built-in not built-in
5% 5%
< 0,01mm < 0,01mm
18 x 18 mm 24 x 24 mm
10 to 30 Vdc 10 to 30 Vdc
± 10% ± 10%
200 mA 200 mA
10 mA 10 mA
2 V 2 V
500Hz 200Hz
short circuit / inversion short circuit / inversion
-25 °C to + 70 °C -25 °C to + 70 °C
IP 67, IP69K IP 67, IP69K
150 g 150 g
2 m PVC 4 wires 0.31 mm2
2 m PVC 4 wires 0.31 mm2
6 m PVC or 2 m PU 6 m PVC or 2 m PU
50, optional 70 mm 50, optional 70 mm
GX, GT, GP GX, GT, GP
BN - brownBU - blueBK - blackWH - white
10 - 30Vdc
BN(1)NPN-A
NO+NC
WH(2)
BK(4)
BU(3) -
+
Ø
Dwg. 44
Dwg. 43
PNP-A2
NO+NC
BN(1)
BK(4)
WH(2)
BU(3)
10 - 30Vdc
+
-
Output Configuration
Mechanical Dimensions
Cable Color
FEATURES
Code Housing
GI nickel plated brass and back light
GX stainless steel and back light
GT PTFE plated brass and back light
GP thermoplastic polyester with fiberglass and back light
50 50 mm tube (standard)
70 70 mm tube (opcional)
M184-Wire
DCCable Connection
Nominal sensing distance
Operating distance
Mounting
Hysteresis
Repeatability
Standard target
Operating voltage range
Ripple
Max. switching current
Current consumption
Output voltage drop
Max. switching frequency
Output indication
Operating temperature range
Protection class
Weight
Connection
Housing options
Standard Line/ Back Light
Drawing
Protection circuit
Cable options
Tube length
back light back light
back light
back light
NO - NPN PS10-30GI50-E Tras. Iluminada P15-30GI50-E Tras. Iluminada
NO - PNP PS10-30GI50-E2 Tras. Iluminada PS15-30GI50-E2 Tras. Iluminada
63 64
10 mm 15 mm
8,1 mm 12,15 mm
built-in not built-in
5% 5%
< 0,01mm < 0,01mm
30 x 30 mm 45 x 45 mm
10 to 30 Vdc 10 to 30 Vdc
± 10% ± 10%
200 mA 200 mA
10 mA 10 mA
2 V 2 V
300Hz 100Hz
short-circuit / inversion short-circuit / inversion
-25 °C to + 70 °C -25 °C to + 70 °C
IP 67, IP69K IP 67, IP69K
205 g 205 g
2 m PVC 3 wires 0.50 mm2
2 m PVC 3 wires 0.50 mm2
6 m PVC ou 2 m PU 6 m PVC ou 2 m PU
50, optional 70 mm 50, optional 70 mm
GX, GT, GP GX, GT, GP
10 - 30Vdc
NPN-E BN(1)
BK(4)
BU(3) -
+
NO
Ø
Dwg. 64Dwg. 63
PNP-E2BN(1)
BU(3)
BK(4) 10 - 30Vdc
-
+
NO
Cable Color Output Configuration
Mechanical Dimensions
BN - brownBU - blueBK - black
FEATURES
Code Housing
GI nickel plated brass and back light
GX stainless steel and back light
GT PTFE plated brass and back light
GP thermoplastic polyester with fiberglass and back light
50 50 mm tube (standard)
70 70 mm tube (opcional)
M303-Wire
DCCable Connection
Nominal sensing distance
Operating distance
Mounting
Hysteresis
Repeatability
Standard target
Operating voltage range
Ripple
Max. switching current
Current consumption
Output voltage drop
Max. switching frequency
Output indication
Protection class
Weight
Connection
Housing options
Standard Line/ Back Light
Operating temperature range
Drawing
Cable options
Tube length
Protection circuit
back light back light
back light
back light
NO + NC - NPN PS10-30GI50-A Tras. Iluminada P15-30GI50-A Tras. Iluminada
NO + NC - PNP PS10-30GI50-A2 Tras. Iluminada PS15-30GI50-A2 Tras. Iluminada
67 68
10 mm 15 mm
8,1 mm 12,15 mm
built-in not built-in
5% 5%
< 0,01mm < 0,01mm
30 x 30 mm 45 x 45 mm
10 to 30 Vdc 10 to 30 Vdc
± 10% ± 10%
200 mA 200 mA
15 mA 15 mA
2 V 2 V
300Hz 100Hz
short-circuit / inversion short-circuit / inversion
-25 °C to + 70 °C -25 °C to + 70 °C
IP 67, IP69K IP 67, IP69K
205 g 205 g
2 m PVC 4 wires 0.50 mm2 2 m PVC 4 wires 0.50 mm2
6 m PVC or 2 m PU 6 m PVC or 2 m PU
50, optional 70 mm 50, optional 70 mm
GX, GT, GP GX, GT, GP
BN - brownBU - blueBK - blackWH- white
10 - 30Vdc
BN(1)NPN-A
NO+NC
WH(2)
BK(4)
BU(3) -
+
Ø
Dwg. 68Dwg. 67
PNP-A2
NO+NC
BN(1)
BK(4)
WH(2)
BU(3)
10 - 30Vdc
+
-
Cable Color Output Configuration
Mechanical Dimensions
FEATURES
Code Housing
GI nickel plated brass and back light
GX stainless steel and back light
GT PTFE plated brass and back light
GP thermoplastic polyester with fiberglass and back light
50 50 mm tube (standard)
70 70 mm tube (opcional)
Nominal sensing distance
Operating distance
Mounting
Hysteresis
Repeatability
Standard target
Operating voltage range
Ripple
Max. switching current
Current consumption
Output voltage drop
Max. switching frequency
Output indication
Protection class
Weight
Connection
Housing options
M304-Wire
DCCable Connection
Standard Line/ Back Light
back light back light
Operating temperature range
Drawing
Cable options
Tube length
Protection circuit
back light
back light
We reserve the right to modify the information herein without previous notice. 2000000176 - Rev. F 12/2014
HEADOFFICE - SAO PAULO
03081-012 São Paulo - SP Phone: 55 11 2145-0444Fax:(11) 2145-0404
600 Joaquim Moreira Carneiro Av. - Santana37540-000 Santa Rita do Sapucaí - MG
Phone: (35) 3471-2555Fax: (35) 3471-2033
1237 Tuiuti Av. - Tatuapé
Fax:(11) [email protected]
FACTORY - MINAS GERAIS
Fax: (35) 3471-2033
www.sense.com.brwww.sense.com.br
Local Distributor