Page 1: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

1 Nexans Cabling Solutions

Increasing Energy Efficiency

IT Room Infra 2011 de Kuip Pieter Heijnen

Page 2: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

2

Connecting the dots, in a reliable way

Page 3: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

3

Consider design & flexibility of structured cabling

Page 4: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

4

IT will be more polluting than

(the Economist)

Unrestrained IT power consumption could eclipse hardware costs and put great pressure on affordability, data center infrastructure and the

Luiz André Barroso, (Google)

Trends

Page 5: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

5

How to reduce energy consumption?

1. Power down servers and switches when idle

2. Reduce power when transceivers are in use

3. Monitor and manage where energy is used

4. Consider design and flexibility of structured cabling

Page 6: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

6

Power down servers and switches when idle

~ 80% ~ 90% Servers in idle state use up to 80% of full load power

Switches in idle state use up to 90% of full load power

Energy Efficient Ethernet (EEE): Low Power Idle

Puts devices to sleep Wake-On-LAN Brings devices back out of sleep

Page 7: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

7

Power down servers and switches when idle

Bron: www.intel.com

Bron: infoworld

Page 8: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

8

Large energy savings possible (e.g. up to 58% saving at 40% utilisation)

Works on Ethernet auto-negotiation

Requires copper cabling

auto-negotiation not available on fibre

External noise could affect recovery time

Shielded cabling better choice

Power Saving with EEE

Page 9: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

9

Reduce power when transceivers are in use

Full power Power Backoff using 10GBase-T

Turn down transmit power over shorter distances

Full power

Page 10: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

10

Benefits of higher grade cabling

Page 11: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

11

>95 .34.1 0

Power Backoff Scale

75-85 26.9-30.5 4

85-95 30.5-34.1 2

55-65 19.8-23.4 8

65-75 23.4-26.9 6

25-45 9.0-16.2 12

45-55 16.2-19.8 10

Length (m) IL 250 MHz (dB) Backoff (dB)

0-25 <9.0 14

Example: 50m Channel: Class EA Insertion Loss > 16.5dB Class EA PBO 10dB LANmark 7a Channel Insertion Loss 13.6dB LANmark 7a PBO 12dB Lower transmit power = greater energy savings

IEEE Power Backoff Scheme

Benefits of higher grade cabling

Page 12: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

12

Reduce power when transceivers are in use (2)

Page 13: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

13

Data Centre design flexibility

Top of Rack or Structured Cabling?

Page 14: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

14

Top of Rack configuration

Advantages:

Cost saving on horizontal copper cabling

Reduction volume of cables under floor

Suitable for high density blade servers

Disadvantages:

Poor Switch port utilisation

Inefficient Power consumption

Extra Maintenance & administration

Expensive & difficult Scalability

Configuration flexibility?

Extra Cost of switches fibre copper

Page 15: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

15

Structured Cabling in data centres

Advantages:

Increased switch port utilisation

Superior energy efficiency

Quickly adapt the system

Easier network expansion

Excellent flexibility

Overall lower cost of ownership

Disadvantages:

More cables needed

More racks needed

Length restrictions on horizontal copper cabling to be respected

fibre copper

Page 16: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

16

Benefits of structured copper cabling

Design flexibility - Longer length, 100m compared to 7m

twinax infiniband - Better port utilisation

No hotspots

LANmark 6A - Shorter links 5m compared to 15m

No air dams

Page 17: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

17

Monitor and manage where energy is used

EMAC Horizontal PDU - manageable

Reports for power usage / temperature / humidity

EMAC Rackmanager

Page 18: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

18

Benefits of higher grade copper cabling

Page 19: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

19

Summary

So basically we can save energy due to:

1. Power down servers and switches when idle

2. Reduce power when transceivers are in use

3. Monitor and manage where energy is used

4. Considering design and flexibility of structured cabling

Page 20: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

20

https://www.nexans.co.uk/eservice/Netherlands-nl_NL/navigate_266412/Energy_Efficiency.html

More on Energy Efficiency ...

Page 21: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

21

Connecting the dots, in a reliable way

Page 22: Increasing Energy Efficiency - Fhi · Increasing Energy Efficiency IT Room Infra 2011 de Kuip Pieter Heijnen . 2 Connecting the dots, in a reliable way ... Unrestrained IT power consumption

22

Invitation to meet Nexans experts

We are happy to invite you, and meet our Nexans Experts:

1. Showcasing our latest LAN innovations

LANmark 6A (multipair & preterm), LANmark 7A & GG45

LANmark OF (MPO solution ready for 40/100G)

LANsense Intelligent Infrastructure Management

2. Discussing and help you with:

latest (DC) standardisation

energy efficiency

network strategy & design Located in Buizingen (Belgium) near Brussels