Impact sound transmission
IMPACT SOUND FROM STAIRS
1
CONCERNING ONLY PRECAST CONCRETE STAIRS
2
IMPACT SOUND TRANSMISSION- A CHALLENGE IN FUTURE
• MORE FOCUS ON ACCESSIBLE SOLUTIONS
• MOST CONSTRUCTIONS CAN NOT SATISFAY COMING NEW REQUIREMENTS
• SOUND TRANSMISSION FROM STAIRS TO NEIGHBOUR ROOMS
• REDUCED QUALITY OF THE FLAT/BUILDING
3
5
TRANSMISSION FROM CONCRETE STAIRS WITHOUT SOUND REDUCING EFFORTS
4
6
65 -70* dB = Normal values in situ build stair/landing Normal values in situ build stair/landing constructionsconstructions
( *= ( *= similar to a normal conversation )
5
Max allowable values for weighted impact sound pressure levels for living houses (in Norway)
6
8
Max allowable values for weighted impact sound pressure levels
(ex. Building regulations in Norway/ Norwegian Standard NS 8175; Class C- buildingsClass C buildings are the most common ( = value for class B))
• Livingroom 53 dB (48 dB for class B)
• School 58 dB
• Hospital 58 dB
• Hotel 58 dB
• Meeting room 58 dB
• Office 63 dB
7
The principle for effective sound reduction
8
10
SOLUTIONS FOR IMPACT SOUND REDUCTION
We have developed products suitable together with ourTSS and RVK units.
These solutions are reducing the impact sound farbelow the limits in the building standards
9
SINTEF* BUILDING AND INFRASTRUCTURE HAVE IN 2007 TESTED OUR SOLUTIONS
Testing of impact sound transmission in two new buildings, and one existing office building in Oslo
Several solutions with TSS and RVK were tested
* = SINTEF is the largest independent research organiztaion in Scandinavia.
10
TSS WITH MASTICORD 6,5 MM PLATE, 72 SHORE
11
TSS AND ELASTOMER SOCK FOR WALL, 58 SHORE
12
TSS WITH ELASOMER SOCK FOR LANDING, 58 SHORE
13
SOLUTIONS FOR IMPACT SOUND REDUCTION
8 - 10 dB 10 - 12 dB 28 - 31 dB Casted Casted Casted
Measured reduction values
14
(15 – 18 dB) (15 – 18 dB)
not casted in not casted in
Recommended solution for living houses
15
Reduction: 28 - 31 dB
Recommended solution for: Schools, Hospitals, Hotels, Meetingroom, Offices
16
Reduction: 10-12 dB
17
SINTEF REPORT MARCH 2008
18
Hints regarding impact sound transmission
19
We have similar products for balcony/walkway to reduce impact sound transmission
20
www.invisibleconnections.no
21
THANK YOU FOR ATTENTION!