Illuminance Spectrophotometer CL-500A...• Measurement and evaluation of the illuminance, color...

4
Illuminance Spectrophotometer For evaluation of high-class next-generation lamps such as LED illumination and EL illumination Now scotopic illuminance can also be measured. Ideal for evaluating CRI (color rendering index) The first illuminance spectrophotometer that conforms to both DIN and JIS standards. Includes convenient, easy-to-use PC software. Both instrument and included software have been upgraded to provide improved instrument operation and software display of MacAdam SDCM levels.

Transcript of Illuminance Spectrophotometer CL-500A...• Measurement and evaluation of the illuminance, color...

Page 1: Illuminance Spectrophotometer CL-500A...• Measurement and evaluation of the illuminance, color temperature, and color-rendering index of special illumination sources used for TV

Illuminance Spectrophotometer

For evaluation of high-class next-generation lamps such as LED illumination and EL illuminationNow scotopic illuminance can also be measured.

Ideal for evaluating CRI (color rendering index)

The fi rst illuminance spectrophotometer that conforms to both DIN and JIS standards. Includes convenient, easy-to-use PC software.

Both instrument and included software have been upgraded to provide improved instrument operation and software display of MacAdam SDCM levels.

Page 2: Illuminance Spectrophotometer CL-500A...• Measurement and evaluation of the illuminance, color temperature, and color-rendering index of special illumination sources used for TV

For correct use and for your safety, be sure to read the instruction manual before using the instrument.●Always connect the instrument to the specified power

supply voltage. Improper connection may cause a fire or electric shock.

SAFETY PRECAUTIONS

Certificate No : JQA-E-80027Registration Date : March 12, 1997

KONICA MINOLTA, Inc., Sakai Site

Certificate No.: JQA-QMA15888Registration Date : October 26, 2018

KONICA MINOLTA, Inc., Sakai SiteProduct design, manufacture/manufacturing

management, calibration, and service

•KONICAMINOLTA,theKonicaMinoltalogoandsymbolmark,and"GivingShapetoideas"areregisteredtrademarksortrademarksofKONICAMINOLTA,INC.

•Windows®andExcel®aretrademarksofMicrosoftCorporationintheUSAandothercountries.

•Thespecificationsandappearanceshownhereinaresubjecttochangewithoutnotice.

•Screensshownareforillustrationpurposeonly.•Somelampcontrolmethodsmaymakeaccurate

measurementsdifficult.Fordetails,pleasecontactyournearestKonicaMinoltasalesofficeordealer.

Model IlluminanceSpectrophotometerCL-500AIlluminancemeterclass

ConformstorequirementsforClassAAofJISC1609-1:2006"IlluminancemetersPart1:Generalmeasuringinstruments"*1

ConformstoDIN5032Part7ClassBWavelengthrange 360to780nmOutputwavelengthpitch

1nm

Spectralbandwidth Approx.10nm(halfbandwidth)Wavelengthprecision ±0.3nm(Medianwavelengthsof435.8nm,546.1nm,and

585.3nm*2asspecifiedinJISZ8724)*3

Measuringrange 0.1to100,000lx(chromaticitydisplayrequires5lxormore)Accuracy*4,5

(StandardIlluminantA)

Ev(Illuminance):±2%±1digitofdisplayedvaluexy:±0.0015(10to100,000lx)xy:±0.002 (5to10lx)

Repeatability(2σ)(StandardIlluminantA)

Ev:0.5%+1digitxy:0.0005 (500to100,000lx)xy:0.001 (100to500lx)xy:0.002 (30to100lx)xy:0.004 (5to30lx)

Visible-regionrelativespectralresponsivitycharacteristics(f1')

Within1.5%ofspectralluminousefficiencyV(λ)

Cosinecorrectioncharacteristics(f2)

Ev:Within3%

Temperaturedrift(fT) Ev:±3%ofdisplayedvalue;xy:±0.003Humiditydrift(fH) Ev:±3%ofdisplayedvalue;xy:±0.003Measurementtime SuperFastmode: Approx.0.2sec.(whenconnectedtocomputer);

Fastmode: Approx.0.5sec.;Slowmode: Approx.2.5sec.;Automaticexposuretimesetting(highaccuracy)mode: Approx.0.5to27sec.

Displaymode XYZ;X10Y10Z10;Evxy;Evu'v';Ev;Dominantwavelength,Excitationpurity;Ev,Correlatedcolortemperature,∆uv;Generalcolor-renderingindex(Ra);Specialcolor-renderingindexes(Ri(i=1~15));Spectralgraph;Peakwavelength;∆(XYZ);∆(X10Y10Z10);∆(Evxy);∆(Evu'v');Rankdisplay;Scotopicilluminance;S/Pratio;Spectralirradiance

Otherfunctions Datamemory:100data;Usercalibrationfunction(whenconnectedtocomputer);Averagedmeasurements;Delayedmeasurement;Continuousmeasurement;Autopowerofffunction

Displaylanguages English,Japanese,Chinese(Simplified)

Interface USB2.0Power Rechargeableinternallithium-ionbattery(Operatingtimeper

charge:Approx.6hourswhennew);ACadapter;USBpowerbus

Operationtemperature/humidityrange

-10to40°C,relativehumidityof85%orless(at35°C)withnocondensation

Storagetemperature/humidityrange

-10to45°C,relativehumidityof85%orless(at35°C)withnocondensation

Size(W×D×H) 70×165×83mmWeight 350g

*1 ForSection7.6.3ResponseTime,whenmeasurementspeedmodeissettoFASTmode.*2 For585.3nm,evaluationperformedusingsubstitutewavelengthof587.5nm.*3 BasedonKonicaMinoltateststandards(changeintemperatureof5°Corlessafterzero

calibration.)*4 Automaticexposuretimesetting(highaccuracy)mode*5 LinearforEv(Illuminance)

Main specifications of Data Management Software CL-S10wType Add-inforExcel®

(Excel®isrequiredtousethisadd-in.)Operatingenvironment

Oneofthefollowingenvironments:Windows®7Professional32-bitor64-bit+Excel®200732-

bitorExcel®201032-bitWindows®8.1Pro32-bit+Excel®201032-bitorExcel®2013

32-bitWindows®8.1Pro64-bit+Excel®201032-bit,Excel®2013

32-bit,orExcel®201364-bitWindows®10Pro32-bit+Excel®201332-bitorExcel®2016

32-bitWindows®10Pro64-bit+Excel®201332-bitor64-bit,or

Excel®201632-bitor64-bit•OSlanguages:English,Japanese,SimplifiedChinese,

TraditionalChinese•Fordetailsonsystemrequirementsforaboveversionsof

Windows®and/orExcel®,refertotheirrespectivespecifications.Compatibleinstruments CL-500A,CL-200A,CL-200Displayitems Spectral irradiance(W/m2/nm); Illuminance;generalcolor-

renderingindexRa;correlatedcolortemperature;etc.

Illuminance measurements (JIS AA Class) also possible

9242-4876-13BIMPKPrintedinJapan

<Standard Accessories> <Optional Accessories>

Wrist StrapCR-A73

CapT-A13 *Shape may vary

by region.

Data Management SoftwareCL-S10w

Hood CL-A11

Illuminance SpectrophotometerCL-500A

USB CableIF-A36

Soft CaseFD-A05

AC adapter *

PC (commercially

available)

Main Specifications of CL-500A

System Diagram Dimensions (Units: mm)

MENU

MEAS.

165

95

95

φ45.2

φ10

.5

φ48Reference plane

Center of receptor window (bottom) Tripod socket; Depth: 5.5

Center of receptor window Tripod socket; Depth: 5.5

Receptor window

7211

70

11.2

Illuminance Spectrophotometer

For evaluation of high-class next-generation lamps such as LED illumination and EL illuminationNow scotopic illuminance can also be measured.

Ideal for evaluating CRI (color rendering index)

New Version

©2011KONICAMINOLTA,INC.

The first illuminance spectrophotometer that conforms to both DIN and JIS standards. Includes convenient, easy-to-use PC software.

Scotopic illuminance can also be measured.Mostconventionalilluminancemeterscanonlymeasurephotopicilluminance,buttheCL-500Acanalsomeasure*scotopic(dark-adapted)illuminancebothwiththeinstrumentaloneandwhenusedwiththeincludedsoftware.Plus,theS/Pratioofscotopicilluminanceandphotopicilluminancecanalsobedisplayed.

*Scotopicvisionvs.photopicvision

Thesensitivityofthehumaneyeunderlow-lightconditionsisdifferentthanthatunderbrightconditions.Thevisionofthehumaneyeunderlow-lightconditionsistermed“scotopicvision”,withasensitivitypeakwavelengthwhichisshiftedtowardtheshorterwavelengthscomparedtovisionunderbrightconditions,whichistermed“photopicvision”.Therespectivespectralluminousefficiencycurvesforeachtypeofvisionareshownatright.

Convenient measurement functions1)Continuousmeasurementmode : Formonitoringchangesinilluminancelevelsorspectralpowerdistribution.2)Displayoftheaverageof multiplemeasurements : Usefulforevaluationofprojectors,etc.3)Delayed-measurementfunction : TheCL-500Acanbesettowaitforaspecifictimeafterthemeasuring

buttonispressedbeforestartingmeasurements,soyoucangetoutofthewaybeforethemeasurementistakentomakesurethatlightreflectedfromyouoryourclothesdonotaffectmeasurements.

4)Displayofdataatspecificwavelength: Allowsmonitoringofspectralirradianceataspecificwavelength.

Main applications:•Measurementandevaluationof the illuminance,color temperature,andcolor-rendering indexof

indoorilluminationsourcessuchasLEDs,organicELsources,fluorescentlamps,etc.•Measurementandevaluationof the illuminance,color temperature,andcolor-rendering indexof

specialilluminationsourcesusedforTVbroadcastingstations,studios,stages,events,etc.•Measurementofambientlightingincludingsunlight.•Measurementoftheilluminationandcolortemperatureofvarioustypesofprojectors.•Measurementofthephotosyntheticphotonfluxdensity(PPFD)oflightsourcesusedforagriculture.•Standardinstrumentforilluminancemetersorilluminancecolorimeters.

CIE

spe

ctra

l lum

inou

s ef

ficie

ncy

Wavelength (nm)

3800.0

0.2

0.4

0.6

0.8

1.0

1.2

420 460 500 540 580 620 660 700 740 780

Photopic vision

Scotopic vision

15

Both instrument and included software have been upgraded to provide improved instrument operation and software display of MacAdam SDCM levels.

360 400 450 550Wavelength (nm)

600500 650 700 750 7800.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

3.00E-01

3.50E-01

4.00E-01

4.50E-01

5.00E-01

Colorsaregenerallycomparedbyarrangingobjectsside-by-sideand lookingat themundernaturallight(sunlight).Whencomparinghowlampssuchasfluorescentlamps,LEDs(lightemittingdiodes),etc.makeobjects lookagainsthownatural lightmakesthemlook,howcloselytheappearancesmatchiscalledthe“color-renderingproperty”ofthelamp.Alampthatproducesahuesimilartothatofnatural light issaid tohaveagood(high)color-renderingproperty.Thecolor-renderingindex isanobjectivequantificationof thecolor-renderingpropertiesofa lightsource.Thecolor-rendering indexexpresses thecomparisonbetweenthe lightsourcebeing testedandastandard illuminant*.Themaximumvalue is100,with thevaluedecreasingas thecolor-renderingdifferenceincreases,indicatinghowfartheappearanceunderthetestlightsourceisfromthenaturalcolorundersunlight.

*Standardilluminantwiththesamecolortemperatureasthelightsourcebeingtested.(Lightalongtheblackbodylocuscorrespondstosunlight.)

What is color-rendering property?

Color-rendering indexes include the general color-rendering index (Ra) and special color-rendering indexes (R1 to R15)

Handheld illuminance spectrophotometer conforms to both DIN and JIS standards.TheCL-500AconformstoDIN5032Part7ClassBandJISC1609-1:2006GeneralClassAA,makingitthefirstcompact,lightweight,handheldilluminancespectrophotometertoconformtobothDINandJISstandards.

Multi-point measurement possibleusing multiple CL-500A unitsDataManagementSoftwareCL-S10wcanbeusedtocontrolupto10CL-500Aunitsformulti-pointmeasurements.UsingtheSDK,thiscanbefurtherexpanded.Pleasecontactoursalespersonforfurtherinformation.

Spectral irradiance waveform displaySincepeakwavelengthscanbeseeneasily,classificationandgradingoflightsourcescanbeperformedeasilyathighaccuracy.Inaddition,numericaldataat1nmcanalsobeviewedinlistform.

Data Management Software CL-S10w (Standard accessory)

Use the CL-500A for CRI (color rendering index) evaluation! Comprehensive software included

Illuminance Spectrophotometer CL-500A Measures color-rendering properties

Chroma Meter CL-200A Measures color temperature

Illuminance Meter T-10A Can measure PWM-controlled lighting

Konica Minolta's Illuminance Measurement Trio

Measurescolor-renderingpropertiesaswellasillumination.DisplaysspectralwaveformusingincludedCL-S10wsoftware.ConformstoDINandJISstandards.

Adefactoindustrystandardforcolor-temperaturemeasurement.Canalsoperformilluminancemeasurements(JISAAClass).Compactandlightweightwithremovablereceptorconnectablewithextensioncables.Includessimple,convenientPCsoftwareasstandardaccessory.

ConformstoDINClassBandJISAAClass.Capableofaccuratelymeasuringnext-generationlampsincludingPWM-controlledlighting.Multiplereceptorscanbeusedformulti-pointmeasurement.AminiaturereceptorT-10MAisalsoavailableformeasuringilluminanceinnarrowspaces.

Measurementsofspectralirradiancearemadepossiblebyusingtheilluminanceadapter.ThismakesitidealforilluminanceevaluationofprojectorsandLEDorELlighting.Thissingleinstrumentcanbeusedformeasuringbothspectralradianceandspectralirradiance.Ourtop-of-the-lineCS-2000isusedformeasuringvarioustypesofhigh-definitiondisplays,andreceivedthe13thAdvancedDisplayoftheYear2008GrandPrizeintheDisplayTestingEquipmentCategory.

Spectralbandwidth: 5nmorless(halfbandwidth)Measurableilluminancerange: 1°measuringangle:0.01to75,000lx 0.1°measuringangle:1.00to7,500,000lx

Illuminance-modified Spectroradiometer CS-2000A

Tolearnmoreaboutthetheoryandpracticeoflightandcolormeasurement,pleasevisithttp://www.konicaminolta.com/instruments/knowledge/index.html

Konica Minolta Measurement Fundamentals

Includes Excel® add-in software as standard accessory.

Convenient, easy-to-use Excel® add-in softwareReadsmeasurementdatafromtheCL-500AdirectlyintoExcel®.FurtherprocessingofdatacanthenbeperformedeasilyusingthevariousfunctionsofExcel®.

0.50

0.40

0.45

0.35

0.30

0.25

0.200.25 0.30 0.35 0.40 0.45 0.50 0.55

50000

+0.02uv

+0.01uv

±0.00uv

-0.01uv

-0.02uv

30000 20

000 15000 13000 10000 9000

8000

7000

6000

5000

4500

4000

3500

3000

2500

y0.90

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 x

520 530

540

550

560

570

590600610620650

680~780

510

500

490

480

470460450 380~440

2000250030003500

40004500

10000

* *

*

***

BC

AD55

D65D75

580

1500

0 20 40 60 80 100

Ra

R1

R2

R3

R4

R5

R6

R7

R8

R9

R10

R11

R12

R13

R14

R15

The general color-rendering index uses low-chroma colors with a Munsell Value of 6 and Chroma between 4 and 8.

No. 9 to No. 15 are realistic colors. No. 15 is the average skin color of Asian women.

No. 1

Test - color samples

No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8

No. 9 No. 10 No. 11 No. 12 No. 13 No. 14 No. 15

Red Yellow Green Blue Average Caucasian skin color

Tree-leave green

Average Asian skin color

Light source being tested

Standard illuminant (CIE daylight)

Cross-section A Illuminance (lx)

Horizontal distance (m)

Hei

ght (

m)

0

0

1

1

2

2

3

3

4-1-2-3

30010050

10

30

5

*BothCL-200AandCL-500AcanmeasurePWM-controlledlight.

Equipped with LED binning function InadditiontoquantifyingthecolorvariationswhichareamajorproblemintheLEDindustry,thesoftwareisalsoequippedwithfunctiontoenableeasybinning.

0.2000

0.2500

0.3000

0.3500

0.4000

0.4500

0.5000

0.2000 0.2500 0.3000 0.3500 0.4000 0.4500 0.5000

Dominant wavelengthBlack body locus2700K

3000K

3500K

4000K

4500K

5000K

5700K6500K

xy

Informative color-rendering index displayColor-renderingindexesareshownvisuallyforeasyunderstanding.Theshiftsbetweenatestlightsourceandastandardlightsourcecanbeseenataglance,withbargraphsshowingthegeneralcolor-renderingindexRa(theaverageofspecialcolor-renderingindexesR1toR8)andthespecialcolor-renderingindexesforatotalof15colors(R1toR15).

MacAdam SDCM level displayCL-S10wincludesatemplateforexpressingthechromaticityvariationofilluminationlightsourcessuchasLEDsororganicELsourcesintermsoftheMacAdamSDCM(StandardDeviationofColorMatching)step.Thisallowsdisplayofcolordifferencesthatcloselymatchvisualjudgment.

0 20 40 60 80 100

Ra

R1

R2

R3

R4

R5

R6

R7

R8

R9

R10

R11

R12

R13

R14

R15

0

100 R1

R2

R3

R4

R5

R6

R7

R8R9

R10

R11

R12

R13

R14

R15

Compact, light-weight, handheld TheCL-500Aweighsonly350g,makingiteasytotakealongortoholdinyourhandformeasurements.

All-in-one type. No PC needed. TheCL-500AcanbeusedbyitselfformeasuringCRIorcolortemperatureoflamps.Inaddition,thespectralirradiancewaveformandpeakwavelengthcanalsobechecked.

Measurement of spectral irradiance (w/m2) at each wavelength.Thespectralirradiancecanbemeasuredat1-nmpitchfrom360to780nm,sotheCL-500Acanbeusednotonlyformeasuringthecoloroflightbutalsoformeasuringphotosyntheticphotonfluxdensity(PPFD).

Measures and displays both the general color-rendering index Ra as well as the special color-rendering indexes R1 to R15. Thespecialcolor-renderingindexesR1toR15canbedisplayed,sothecolor-renderingindexforaspecificcolorsuchasforR9(red)orR15(skincolor)canbeeasilymeasuredanddisplayed.

High-speed measurement possibleUsingthe*SDK,high-speedmeasurementsat5times/sec.canbetaken.*SoftwareDevelopmentKit

SDCM of 2700K

Dominant WavelengthBlackbody LocusMacAdam Ellipsesxy

0.0000

0.1000

0.2000

0.3000

0.4000

0.5000

0.6000

0.7000

0.8000

0.9000

0.0000 0.1000 0.2000 0.3000 0.4000 0.5000 0.6000 0.7000 0.8000

0.4000

0.4050

0.4100

0.4150

0.4200

0.4250

0.4300

0.4350

0.4400

0.4450 0.4500 0.4550 0.4600 0.4650 0.4700 0.4750 0.4800

Page 3: Illuminance Spectrophotometer CL-500A...• Measurement and evaluation of the illuminance, color temperature, and color-rendering index of special illumination sources used for TV

360 400 450 550Wavelength (nm)

600500 650 700 750 7800.00E+00

5.00E-02

1.00E-01

1.50E-01

2.00E-01

2.50E-01

3.00E-01

3.50E-01

4.00E-01

4.50E-01

5.00E-01

Colorsaregenerallycomparedbyarrangingobjectsside-by-sideand lookingat themundernaturallight(sunlight).Whencomparinghowlampssuchasfluorescentlamps,LEDs(lightemittingdiodes),etc.makeobjects lookagainsthownatural lightmakesthemlook,howcloselytheappearancesmatchiscalledthe“color-renderingproperty”ofthelamp.Alampthatproducesahuesimilartothatofnatural light issaid tohaveagood(high)color-renderingproperty.Thecolor-renderingindex isanobjectivequantificationof thecolor-renderingpropertiesofa lightsource.Thecolor-rendering indexexpresses thecomparisonbetweenthe lightsourcebeing testedandastandard illuminant*.Themaximumvalue is100,with thevaluedecreasingas thecolor-renderingdifferenceincreases,indicatinghowfartheappearanceunderthetestlightsourceisfromthenaturalcolorundersunlight.

*Standardilluminantwiththesamecolortemperatureasthelightsourcebeingtested.(Lightalongtheblackbodylocuscorrespondstosunlight.)

What is color-rendering property?

Color-rendering indexes include the general color-rendering index (Ra) and special color-rendering indexes (R1 to R15)

Handheld illuminance spectrophotometer conforms to both DIN and JIS standards.TheCL-500AconformstoDIN5032Part7ClassBandJISC1609-1:2006GeneralClassAA,makingitthefirstcompact,lightweight,handheldilluminancespectrophotometertoconformtobothDINandJISstandards.

Multi-point measurement possibleusing multiple CL-500A unitsDataManagementSoftwareCL-S10wcanbeusedtocontrolupto10CL-500Aunitsformulti-pointmeasurements.UsingtheSDK,thiscanbefurtherexpanded.Pleasecontactoursalespersonforfurtherinformation.

Spectral irradiance waveform displaySincepeakwavelengthscanbeseeneasily,classificationandgradingoflightsourcescanbeperformedeasilyathighaccuracy.Inaddition,numericaldataat1nmcanalsobeviewedinlistform.

Data Management Software CL-S10w (Standard accessory)

Use the CL-500A for CRI (color rendering index) evaluation! Comprehensive software included

Illuminance Spectrophotometer CL-500A Measures color-rendering properties

Chroma Meter CL-200A Measures color temperature

Illuminance Meter T-10A Can measure PWM-controlled lighting

Konica Minolta's Illuminance Measurement Trio

Measurescolor-renderingpropertiesaswellasillumination.DisplaysspectralwaveformusingincludedCL-S10wsoftware.ConformstoDINandJISstandards.

Adefactoindustrystandardforcolor-temperaturemeasurement.Canalsoperformilluminancemeasurements(JISAAClass).Compactandlightweightwithremovablereceptorconnectablewithextensioncables.Includessimple,convenientPCsoftwareasstandardaccessory.

ConformstoDINClassBandJISAAClass.Capableofaccuratelymeasuringnext-generationlampsincludingPWM-controlledlighting.Multiplereceptorscanbeusedformulti-pointmeasurement.AminiaturereceptorT-10MAisalsoavailableformeasuringilluminanceinnarrowspaces.

Measurementsofspectralirradiancearemadepossiblebyusingtheilluminanceadapter.ThismakesitidealforilluminanceevaluationofprojectorsandLEDorELlighting.Thissingleinstrumentcanbeusedformeasuringbothspectralradianceandspectralirradiance.Ourtop-of-the-lineCS-2000isusedformeasuringvarioustypesofhigh-definitiondisplays,andreceivedthe13thAdvancedDisplayoftheYear2008GrandPrizeintheDisplayTestingEquipmentCategory.

Spectralbandwidth: 5nmorless(halfbandwidth)Measurableilluminancerange: 1°measuringangle:0.01to75,000lx 0.1°measuringangle:1.00to7,500,000lx

Illuminance-modified Spectroradiometer CS-2000A

Tolearnmoreaboutthetheoryandpracticeoflightandcolormeasurement,pleasevisithttp://www.konicaminolta.com/instruments/knowledge/index.html

Konica Minolta Measurement Fundamentals

Includes Excel® add-in software as standard accessory.

Convenient, easy-to-use Excel® add-in softwareReadsmeasurementdatafromtheCL-500AdirectlyintoExcel®.FurtherprocessingofdatacanthenbeperformedeasilyusingthevariousfunctionsofExcel®.

0.50

0.40

0.45

0.35

0.30

0.25

0.200.25 0.30 0.35 0.40 0.45 0.50 0.55

50000

+0.02uv

+0.01uv

±0.00uv

-0.01uv

-0.02uv

30000 20

000 15000 13000 10000 9000

8000

7000

6000

5000

4500

4000

3500

3000

2500

y0.90

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 x

520 530

540

550

560

570

590600610620650

680~780

510

500

490

480

470460450 380~440

2000250030003500

40004500

10000

* *

*

***

BC

AD55

D65D75

580

1500

0 20 40 60 80 100

Ra

R1

R2

R3

R4

R5

R6

R7

R8

R9

R10

R11

R12

R13

R14

R15

The general color-rendering index uses low-chroma colors with a Munsell Value of 6 and Chroma between 4 and 8.

No. 9 to No. 15 are realistic colors. No. 15 is the average skin color of Asian women.

No. 1

Test - color samples

No. 2 No. 3 No. 4 No. 5 No. 6 No. 7 No. 8

No. 9 No. 10 No. 11 No. 12 No. 13 No. 14 No. 15

Red Yellow Green Blue Average Caucasian skin color

Tree-leave green

Average Asian skin color

Light source being tested

Standard illuminant (CIE daylight)

Cross-section A Illuminance (lx)

Horizontal distance (m)H

eigh

t (m

)0

0

1

1

2

2

3

3

4-1-2-3

30010050

10

30

5

*BothCL-200AandCL-500AcanmeasurePWM-controlledlight.

Equipped with LED binning function InadditiontoquantifyingthecolorvariationswhichareamajorproblemintheLEDindustry,thesoftwareisalsoequippedwithfunctiontoenableeasybinning.

0.2000

0.2500

0.3000

0.3500

0.4000

0.4500

0.5000

0.2000 0.2500 0.3000 0.3500 0.4000 0.4500 0.5000

Dominant wavelengthBlack body locus2700K

3000K

3500K

4000K

4500K

5000K

5700K6500K

xy

Informative color-rendering index displayColor-renderingindexesareshownvisuallyforeasyunderstanding.Theshiftsbetweenatestlightsourceandastandardlightsourcecanbeseenataglance,withbargraphsshowingthegeneralcolor-renderingindexRa(theaverageofspecialcolor-renderingindexesR1toR8)andthespecialcolor-renderingindexesforatotalof15colors(R1toR15).

MacAdam SDCM level displayCL-S10wincludesatemplateforexpressingthechromaticityvariationofilluminationlightsourcessuchasLEDsororganicELsourcesintermsoftheMacAdamSDCM(StandardDeviationofColorMatching)step.Thisallowsdisplayofcolordifferencesthatcloselymatchvisualjudgment.

0 20 40 60 80 100

Ra

R1

R2

R3

R4

R5

R6

R7

R8

R9

R10

R11

R12

R13

R14

R15

0

100 R1

R2

R3

R4

R5

R6

R7

R8R9

R10

R11

R12

R13

R14

R15

Compact, light-weight, handheld TheCL-500Aweighsonly350g,makingiteasytotakealongortoholdinyourhandformeasurements.

All-in-one type. No PC needed. TheCL-500AcanbeusedbyitselfformeasuringCRIorcolortemperatureoflamps.Inaddition,thespectralirradiancewaveformandpeakwavelengthcanalsobechecked.

Measurement of spectral irradiance (w/m2) at each wavelength.Thespectralirradiancecanbemeasuredat1-nmpitchfrom360to780nm,sotheCL-500Acanbeusednotonlyformeasuringthecoloroflightbutalsoformeasuringphotosyntheticphotonfluxdensity(PPFD).

Measures and displays both the general color-rendering index Ra as well as the special color-rendering indexes R1 to R15. Thespecialcolor-renderingindexesR1toR15canbedisplayed,sothecolor-renderingindexforaspecificcolorsuchasforR9(red)orR15(skincolor)canbeeasilymeasuredanddisplayed.

High-speed measurement possibleUsingthe*SDK,high-speedmeasurementsat5times/sec.canbetaken.*SoftwareDevelopmentKit

SDCM of 2700K

Dominant WavelengthBlackbody LocusMacAdam Ellipsesxy

0.0000

0.1000

0.2000

0.3000

0.4000

0.5000

0.6000

0.7000

0.8000

0.9000

0.0000 0.1000 0.2000 0.3000 0.4000 0.5000 0.6000 0.7000 0.8000

0.4000

0.4050

0.4100

0.4150

0.4200

0.4250

0.4300

0.4350

0.4400

0.4450 0.4500 0.4550 0.4600 0.4650 0.4700 0.4750 0.4800

Page 4: Illuminance Spectrophotometer CL-500A...• Measurement and evaluation of the illuminance, color temperature, and color-rendering index of special illumination sources used for TV

For correct use and for your safety, be sure to read the instruction manual before using the instrument.●Always connect the instrument to the specified power

supply voltage. Improper connection may cause a fire or electric shock.

SAFETY PRECAUTIONS ISO Certifications of KONICA MINOLTA, Inc., Sakai Site

JQA-E-80027 Design, development,

manufacture, service and sales of measuring instruments

JQA-QMA15888Design, development, manufacture/

manufacturing management, calibration, and service of measuring instruments

• KONICA MINOLTA, the Konica Minolta logo and symbol mark, and "Giving Shape to ideas" are registered trademarks or trademarks of KONICA MINOLTA, INC.

• Windows® and Excel® are trademarks of Microsoft Corporation in the USA and other countries.

• The specifi cations and appearance shown herein are subject to change without notice.

• Screens shown are for illustration purpose only.• Some lamp control methods may make accurate

measurements diffi cult. For details, please contact your nearest Konica Minolta sales offi ce or dealer.

Model Illuminance Spectrophotometer CL-500AIlluminance meter class

Conforms to requirements for Class AA of JIS C 1609-1: 2006 "Illuminance meters Part 1: General measuring instruments"*1

Conforms to DIN 5032 Part 7 Class BWavelength range 360 to 780 nmOutput wavelength pitch

1 nm

Spectral bandwidth Approx. 10 nm (half bandwidth)Wavelength precision ±0.3 nm (Median wavelengths of 435.8 nm, 546.1 nm, and

585.3 nm*2 as specifi ed in JIS Z 8724)*3

Measuring range 0.1 to 100,000 lx (chromaticity display requires 5 lx or more)Accuracy*4, 5

(Standard Illuminant A)

Ev (Illuminance) : ±2%±1 digit of displayed valuexy: ±0.0015 (10 to 100,000 lx)xy: ±0.002 (5 to 10 lx)

Repeatability (2σ)(Standard Illuminant A)

Ev: 0.5%+1 digitxy: 0.0005 (500 to 100,000 lx)xy: 0.001 (100 to 500 lx)xy: 0.002 (30 to 100 lx)xy: 0.004 (5 to 30 lx)

Visible-region relative spectral responsivity characteristics (f1')

Within 1.5% of spectral luminous effi ciency V (λ)

Cosine correction characteristics (f2)

Ev: Within 3%

Temperature drift (fT) Ev: ±3% of displayed value; xy: ±0.003 Humidity drift (fH) Ev: ±3% of displayed value; xy: ±0.003 Measurement time Super Fast mode: Approx. 0.2 sec. (when connected to computer);

Fast mode: Approx. 0.5 sec.;Slow mode: Approx. 2.5 sec.;Automatic exposure time setting (high accuracy) mode: Approx. 0.5 to 27 sec.

Display mode XYZ; X10Y10Z10; Evxy; Evu'v'; Ev; Dominant wavelength, Excitation purity; Ev, Correlated color temperature, ∆uv; General color-rendering index (Ra); Special color-rendering indexes (Ri (i=1~15)); Spectral graph; Peak wavelength; ∆ (XYZ); ∆ (X10Y10Z10); ∆ (Evxy); ∆ (Evu'v'); Rank display; Scotopic illuminance; S/P ratio; Spectral irradiance

Other functions Data memory: 100 data; User calibration function (when connected to computer); Averaged measurements; Delayed measurement; Continuous measurement; Auto power off function

Display languages English, Japanese, Chinese (Simplifi ed)

Interface USB 2.0Power Rechargeable internal lithium-ion battery (Operating time per

charge: Approx. 6 hours when new); AC adapter; USB power bus

Operation temperature/humidity range

-10 to 40°C, relative humidity of 85% or less (at 35°C) with no condensation

Storage temperature/ humidity range

-10 to 45°C, relative humidity of 85% or less (at 35°C) with no condensation

Size (W × D × H) 70 × 165 × 83 mmWeight 350 g

*1 For Section 7.6.3 Response Time, when measurement speed mode is set to FAST mode.*2 For 585.3 nm, evaluation performed using substitute wavelength of 587.5 nm.*3 Based on Konica Minolta test standards (change in temperature of 5°C or less after zero

calibration.)*4 Automatic exposure time setting (high accuracy) mode*5 Linear for Ev (Illuminance)

Main specifi cations of Data Management Software CL-S10wType Add-in for Excel®

(Excel® is required to use this add-in.)Operating environment

One of the following environments:Windows® 7 Professional 32-bit or 64-bit + Excel® 2007 32-

bit or Excel® 2010 32-bitWindows® 8.1 Pro 32-bit + Excel® 2010 32-bit or Excel® 2013

32-bitWindows® 8.1 Pro 64-bit + Excel® 2010 32-bit, Excel® 2013

32-bit, or Excel® 2013 64-bitWindows® 10 Pro 32-bit + Excel® 2013 32-bit or Excel® 2016

32-bitWindows® 10 Pro 64-bit + Excel® 2013 32-bit or 64-bit, or

Excel® 2016 32-bit or 64-bit• OS languages: English, Japanese, Simplifi ed Chinese,

Traditional Chinese• For details on system requirements for above versions of

Windows® and/or Excel®, refer to their respective specifi cations.Compatible instruments CL-500A, CL-200A, CL-200Display items Spectral irradiance (W/m2/nm); Illuminance; general color-

rendering index Ra; correlated color temperature; etc.

9242-4876-13 BJDPK 16

<Standard Accessories> <Optional Accessories>

Wrist StrapCR-A73

CapT-A13 *Shape may vary

by region.

Data Management SoftwareCL-S10w

Hood CL-A11

Illuminance SpectrophotometerCL-500A

USB CableIF-A36

Soft CaseFD-A05

AC adapter *

PC (commercially

available)

Main Specifi cations of CL-500A

System Diagram Dimensions (Units: mm)

MENU

MEAS.

165

95

95

φ45.2

φ10

.5

φ48Reference plane

Center of receptor window (bottom) Tripod socket; Depth: 5.5

Center of receptor window Tripod socket; Depth: 5.5

Receptor window

7211

70

11.2

©2011 KONICA MINOLTA, INC.