IFRC SRU SD VUB Frame for Family Tent Feasibility Study
-
Upload
amjad-pervaz -
Category
Documents
-
view
220 -
download
1
description
Transcript of IFRC SRU SD VUB Frame for Family Tent Feasibility Study
10. Application in IFRC Family Shelterv
. Aim
→ Robust frame that fits in the canvas of the IFRC family shelter
→ Based on the Flexible and integrated shelter approach
Pag.15-11-2011
1Herhaling titel van presentatie
2
+ +
10. Application in IFRC Family Shelterv
. Existing design: family shelter
Pag.15-11-2011
2Herhaling titel van presentatie
2
10. Application in IFRC Family Shelterv
. Existing design: family shelter
→ Irregular shape:
wall height differs from door height
floor plan is an irregular octagon
Pag.15-11-2011
3Herhaling titel van presentatie
2
10. Application in IFRC Family Shelterv
. Existing design: family shelter
→ Different bar lengths (m):
1,25 – 1,40 – 1,68 – 1,85 - 2,00 – 2,21
→ Different required angles (°):
115,4 – 118,5 – 129,2 - 135
Pag.15-11-2011
4Herhaling titel van presentatie
2
10. Application in IFRC Family Shelterv
. Step 1: emergency kit
→ Replacing the existing bars by using the emergency kit→ L-profiles can be combined with transitional shelter kit
Shelter built with L-profiles
Pag.15-11-2011
5Herhaling titel van presentatie
2
10. Application in IFRC Family Shelterv
. Step 2: specific components
→ Specific connection elements for each connection→ All the angles possible
BUT→ More than 20 different connection plates
Pag.15-11-2011
6Herhaling titel van presentatie
2
Specific topConnection (5 different plates)
Specific sideConnection(4 different plates)
10. Application in IFRC Family Shelterv
. Step 3: connection plates
→ Adjusted connection plates→ Basic frame possible
AND→ Complement with a few specific elements
Pag.15-11-2011
7Herhaling titel van presentatie
2
frame built up with adjusted connection plates
Required angles: 115°, 120°, 130°, 135°Additional angles: 105°, 140°, 150°
10. Application in IFRC Family Shelterv
. Step 3: connection plates
→ Adjusted connection plates→ Basic frame possible
AND→ Complement with a few specific elements
Pag.15-11-2011
8Herhaling titel van presentatie
2
frame built up with adjusted connection plates
Specific components tocomplete the shelter
10. Application in IFRC Family Shelterv
. Step 3: calculations
Wind-load Wind-load
Transitional Shelter Standards
(draft Dec 2010)64,8km/h or 18 m/s wind velocity stormy weather
IFCR Family shelter 75km/h or 21 m/s wind velocity storm
Pag.15-11-2011
9Herhaling titel van presentatie
2
IFCR Family shelter 75km/h or 21 m/s wind velocity storm
Transitional shelter
(SRU research project)115km/h or 32 m/s wind velocity very heavy tropical storm
10. Application in IFRC Family Shelterv
. Step 3: calculations
Length [m] Cross section
BARS 32 m/s 21 m/s
Ridge 2,00 80x80x4 40x40x3
Vertical wall 1,25 80x80x3 40x40x3
Horizontal wall 2,00 80x80x3 40x40x5
Vertical door 1,40 80x80x4 40x40x3
Pag.15-11-2011
10Herhaling titel van presentatie
2
Vertical door 1,40 80x80x4 40x40x3
Horizontal door 1,40 40x40x3 40x40x3
Door-top 1,68 80x80x3 40x40x3
Wall-top 2,21 80x80x3 40x40x3
Wall-door ridge 1,85 40x40x3 40x40x3
Cables 42,7
Total weight [kg] 161,9 98,2
WEIGHT steel CABLES [kg] 26,3
Total weight WITHOUT CABLES [kg] 135,6 71,9
10. Application in IFRC Family Shelterv
. Step 4 to 7: adjusted shape
Wall height
Amount of different bars
Octagon
Amount of different bars Amount of specific connection plates
Top height Shape
Pag.15-11-2011
11Herhaling titel van presentatie
2
Name
Different
bars Wall angles [°]
Specific top
angles Ring angles [°]
Useful floor
area [m²]
Existing family shelter 7 115° and 118° 5 / 23,2
Wall height 6 118° 5 135° 23,2
Octagon 4 118° 3 120° and 150° 26,4
Top height 4 120° 3 120° and 150° 26,4
Shape 3 various 1 90° various
Top height
Simplified connection plate
Shape
Amount of different bars Amount of specific connection plates More simplified connection plate