IES LM-79-08 - JLS- · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd...

12
STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For Jaykal LED Solutions,Inc 35765 Black Marlin Drive Lewes, Delaware 19958, USA Test Model: JLS68103-G200-SBCL Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, THD, Power Factor, Off-state Power Test Engineer: Daniel Duan Report Number: RSZ140815503-10 Test Date: 2014-08-18 to 2014-08-19 Report Date: 2014-08-20 Reviewed By: Jeanne Han/Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0.

Transcript of IES LM-79-08 - JLS- · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd...

STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.

(Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification,

approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.

This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

IES LM-79-08

MEASUREMENT AND TEST REPORT For

Jaykal LED Solutions,Inc 35765 Black Marlin Drive Lewes, Delaware 19958, USA

Test Model: JLS68103-G200-SBCL

Report Type:

Electrical and Photometric tests including: Luminous Flux,

Color, Luminous Intensity Distribution, THD, Power

Factor, Off-state Power

Test Engineer: Daniel Duan

Report Number: RSZ140815503-10

Test Date: 2014-08-18 to 2014-08-19

Report Date: 2014-08-20

Reviewed By: Jeanne Han/Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen)

6/F, the 3rd Phase of WanLi Industrial Building,

ShiHua Road, FuTian Free Trade Zone

Shenzhen, Guangdong, China

Tel: +86-755-33320018

Fax: +86-755-33320008

Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial

Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

Accreditation: The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 2 of 12 The NVLAP Lab Code is 200707-0.

1. Product Description

General Information:

One sample was received on 2014-08-15 and used for testing. Sample No.: RSZ140815503-S01 Model: JLS68103-G200-SBCL

Model Tested: JLS68103-G200-SBCL

Manufacturer: Jaykal LED Solutions,Inc

Brand Name: Jaykal

Product Designation: Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

Burning Time Before Test: 0 hour(For New Products)

Rated Values:

Rated Voltage/Frequency: 90-305VAC 50/60Hz

Rated Power: 200W

Nominal CCT: 5000K

2. Standards Used

IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products

ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration

due date

Integrating

Sphere SENSING SPR-600 S09008 1.5 meter 2014-03-16 2015-03-16

Spectral

photometer SENSING SPR3000 90902027 350nm~800nm 2014-03-16 2015-03-16

Power Meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/600 V 2014-03-12 2015-03-12

AC Power Supply ALL Power APW-

105N 970613 0V-300V 50-400Hz 2014-03-12 2015-03-12

Standard Light

Source EVERFINE D204 201311 N/A 2013-09-26 2014-09-26

Thermal Meter SENSING N/A N/A 25℃,45℃,55℃ 2014-03-16 2015-03-16

DC Power Supply ITECH IT6154 0061 0417 6471 0010

19 0~60V 2014-03-12 2015-03-12

AC Power Supply EVERFINE VPS1060

PWM 1101006 0-150V, 0-300V 2014-03-12 2015-03-12

DC Power Supply EVERFINE WY12010 1009009 30V/5A 2014-03-12 2015-03-12

Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2014-03-12 2015-03-12

Goniophotometer EVERFINE GO-R5000 YG108492N10120001 1600mm,3000W/10A 2014-03-04 2015-03-04

Thermal Meter Victor VC230 EE091 0~40℃0~90% 2013-04-01 2016-03-31

Standard Light

Source EVERFINE D908 1012001 N/A 2014-05-06 2015-05-06

Digital Power

Meter EVERFINE PF9811 507047 0~35V DC 2013-11-12 2014-11-12

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 3 of 12 The NVLAP Lab Code is 200707-0.

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration

due date

AC POWER

SUPPLY SZHPC HPA 1103 0003394 3KVA 2014-03-12 2015-03-12

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been

performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement. The system and standard light source has been calibrated regularly and traceable to the National Primary Standards.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=1.64% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=1.6 (K=2) , at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement. The standard light source has been calibrated regularly and traceable to the National Primary Standards.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

Additional Test

The Additional Test item may not be covered by IESNA LM-79-2008. Additional test including power factor, off-state power and THD, was measured by Digital Power Meter after stabilized at 25°C±1°C.Test voltage for THD and power factor test would be equal to rated voltage or, in case of a voltage range, maximum value of that range.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at

the 95% confidence level.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 4 of 12 The NVLAP Lab Code is 200707-0.

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 2.0 hours

Test orientation: Downward

Electrical Measurement

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

120.13 60.0 1.5563 186.21 0.996

Photometric Measurement

Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

15389.856 28.262 82.649 5150 6.84E-03

Chromaticity Coordinate

x y u v u' v'

0.3420 0.3630 0.2051 0.3264 0.2051 0.4896

Color Rendering Index

Ra

69.8

R1 R2 R3 R4

67 73 78 72

R5 R6 R7 R8

68 64 79 57

R9 R10 R11 R12

-34 37 69 41

R13 R14 R15

68 87 61

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 5 of 12 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution

nm mW

nm mW

nm mW

nm mW

nm mW

380 1.874E-02 465 3.080E-01 550 7.873E-01 635 3.926E-01 720 4.473E-02

385 1.321E-02 470 2.063E-01 555 7.888E-01 640 3.538E-01 725 3.934E-02

390 8.674E-03 475 1.515E-01 560 7.929E-01 645 3.190E-01 730 3.386E-02

395 7.114E-03 480 1.281E-01 565 7.862E-01 650 2.838E-01 735 3.033E-02

400 7.648E-03 485 1.260E-01 570 7.770E-01 655 2.534E-01 740 2.606E-02

405 1.197E-02 490 1.458E-01 575 7.709E-01 660 2.248E-01 745 2.294E-02

410 2.539E-02 495 1.954E-01 580 7.536E-01 665 1.971E-01 750 2.020E-02

415 5.866E-02 500 2.725E-01 585 7.401E-01 670 1.746E-01 755 1.806E-02

420 1.237E-01 505 3.672E-01 590 7.208E-01 675 1.532E-01 760 1.632E-02

425 2.390E-01 510 4.667E-01 595 6.902E-01 680 1.340E-01 765 1.436E-02

430 3.970E-01 515 5.593E-01 600 6.638E-01 685 1.180E-01 770 1.278E-02

435 6.233E-01 520 6.360E-01 605 6.317E-01 690 1.020E-01 775 1.156E-02

440 9.453E-01 525 6.915E-01 610 5.916E-01 695 8.973E-02 780 1.043E-02

445 1.207E+00 530 7.337E-01 615 5.508E-01 700 7.794E-02 785 9.732E-03

450 1.080E+00 535 7.574E-01 620 5.172E-01 705 6.811E-02 790 8.850E-03

455 7.102E-01 540 7.718E-01 625 4.738E-01 710 5.928E-02 795 8.167E-03

460 4.464E-01 545 7.817E-01 630 4.338E-01 715 5.182E-02 800 7.841E-03

0.0

0.2

0.4

0.6

0.8

1.0

1.2

380 440 500 560 620 680 740 800

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 6 of 12 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram

7-Step & 4-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50

sample

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

4-STEP 2700K

4-STEP 3000K

4-STEP 3500K

4-STEP 4000K

4-STEP 5000K

4-STEP 6500K

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 7 of 12 The NVLAP Lab Code is 200707-0.

[Goniophotometer System]

Total operating time for luminous intensity distribution: 2.0 hours

Test orientation: Downward

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

120.2 60.0 1.533 185.7 0.9953

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) CBCP (cd) S/MH (C0/180) S/MH (C90/270)

15474.3 83.34 5893 1.31 1.28

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 109.0 108.9 105.4 108.9 108.05

Field Angle (10% Imax): 151.0 150.9 148.9 151.5 150.58

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 8 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data

C

0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 5893 5893 5893 5893 5893 5893 5893 5893

5.0° 5921 5934 5941 5924 5899 5887 5887 5884

10.0° 5897 5925 5930 5891 5846 5825 5829 5833

15.0° 5812 5856 5861 5815 5741 5703 5708 5717

20.0° 5670 5722 5735 5674 5581 5522 5528 5538

25.0° 5478 5527 5542 5486 5369 5284 5282 5309

30.0° 5221 5274 5292 5232 5100 4999 4989 5026

35.0° 4934 4979 4980 4920 4783 4671 4653 4702

40.0° 4597 4634 4618 4562 4335 4303 4293 4346

45.0° 4216 4240 4214 3959 3800 3689 3890 3946

50.0° 3508 3660 3760 3527 3374 3254 3405 3522

55.0° 3070 3072 3142 2937 2781 2691 2839 2939

60.0° 2376 2484 2455 2464 2363 2234 2365 2445

65.0° 1843 1921 1891 1892 1768 1707 1748 1830

70.0° 1281 1275 1304 1317 1160 1152 1214 1203

75.0° 680 690 723 698 610 648 678 687

80.0° 216 236 238 205 155 188 234 232

85.0° 31 30 34 36 36 40 39 37

90.0° 0 0 0 0 0 0 0 0

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 0 0 0 0 0 0

105.0° 0 0 0 0 0 0 0 0

110.0° 0 0 0 0 0 0 0 0

115.0° 0 0 0 0 0 0 0 0

120.0° 0 0 0 0 0 0 0 0

125.0° 0 0 0 0 0 0 0 0

130.0° 0 0 0 0 0 0 0 0

135.0° 0 0 0 0 0 0 0 0

140.0° 0 0 0 0 0 0 0 0

145.0° 0 0 0 0 0 0 0 0

150.0° 0 0 0 0 0 0 0 0

155.0° 0 0 0 0 0 0 0 0

160.0° 0 0 0 0 0 0 0 0

165.0° 0 0 0 0 0 0 0 0

170.0° 0 0 0 0 0 0 0 0

175.0° 0 0 0 0 0 0 0 0

180.0° 0 0 0 0 0 0 0 0

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 9 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.)

C

180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 5893 5893 5893 5893 5893 5893 5893 5893

5.0° 5811 5797 5800 5816 5837 5846 5851 5844

10.0° 5684 5662 5663 5687 5724 5742 5761 5751

15.0° 5511 5480 5477 5518 5562 5593 5613 5610

20.0° 5299 5256 5256 5294 5344 5392 5422 5419

25.0° 5052 5002 4991 5024 5089 5146 5183 5195

30.0° 4769 4721 4693 4724 4794 4862 4900 4942

35.0° 4472 4418 4368 4387 4461 4543 4591 4647

40.0° 4145 4088 4023 4026 4051 4194 4256 4318

45.0° 3784 3730 3657 3433 3533 3661 3893 3957

50.0° 3389 3343 3271 3044 3141 3265 3457 3466

55.0° 2761 2770 2679 2642 2581 2817 2962 2903

60.0° 2308 2316 2274 2073 2016 2233 2306 2378

65.0° 1694 1716 1666 1505 1459 1619 1766 1808

70.0° 1134 1176 1082 984 967 1088 1142 1205

75.0° 614 629 593 523 469 545 624 646

80.0° 193 203 196 178 147 183 201 206

85.0° 27 32 37 42 41 40 31 29

90.0° 0 0 0 0 0 0 0 0

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 0 0 0 0 0 0

105.0° 0 0 0 0 0 0 0 0

110.0° 0 0 0 3 0 1 0 0

115.0° 0 0 0 1 0 0 0 0

120.0° 0 0 0 1 0 1 0 0

125.0° 0 0 0 0 1 0 0 0

130.0° 0 0 0 0 0 0 0 0

135.0° 0 0 0 0 0 0 0 0

140.0° 0 0 0 0 0 0 0 0

145.0° 0 0 0 0 0 0 0 0

150.0° 0 0 0 0 0 0 0 0

155.0° 0 0 0 0 0 0 0 0

160.0° 0 0 0 0 0 0 0 0

165.0° 0 0 0 0 0 0 0 0

170.0° 0 0 0 0 0 0 0 0

175.0° 0 0 0 0 0 0 0 0

180.0° 0 0 0 0 0 0 0 0

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 10 of 12 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure

Height (m) Diameter

(cm) Eavg(lx) Emax(lx)

0.5 137.9 7379.0 24612.0

1.0 275.8 1845.0 6153.0

1.5 413.7 819.9 2735.0

2.0 551.6 461.2 1538.0

2.5 689.5 295.2 984.5

3.0 827.3 205.0 683.7

3.5 965.2 150.6 502.3

4.0 1103.1 115.3 384.6

4.5 1241.0 91.1 303.9

5.0 1378.9 73.8 246.1

Angle: 108.10°. Flux out: 11821.0 lm.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 11 of 12 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement

Deg Flux (lm) %

Deg Flux (lm) %

0-5 140.6 0.91 0-5 140.6 0.91

5-10 417.1 2.69 0-10 557.7 3.60

10-15 679.3 4.39 0-15 1237.0 7.99

15-20 918.1 5.94 0-20 2155.0 13.93

20-25 1124.9 7.27 0-25 3279.9 21.20

25-30 1293.1 8.35 0-30 4573.0 29.55

30-35 1417.9 9.17 0-35 5990.9 38.72

35-40 1495.4 9.66 0-40 7486.3 48.38

40-45 1508.6 9.75 0-45 8995.0 58.13

45-50 1469.0 9.49 0-50 10464.0 67.62

50-55 1356.6 8.77 0-55 11820.6 76.39

55-60 1197.1 7.73 0-60 13017.7 84.12

60-65 982.7 6.35 0-65 14000.3 90.47

65-70 733.9 4.75 0-70 14734.2 95.22

70-75 467.7 3.02 0-75 15201.9 98.24

75-80 214.7 1.39 0-80 15416.6 99.63

80-85 51.1 0.33 0-85 15467.7 99.96

85-90 6.2 0.04 0-90 15473.9 100.00

90-95 0.0 0.00 0-95 15473.9 100.00

95-100 0.0 0.00 0-100 15474.0 100.00

100-105 0.0 0.00 0-105 15474.0 100.00

105-110 0.1 0.00 0-110 15474.0 100.00

110-115 0.1 0.00 0-115 15474.2 100.00

115-120 0.0 0.00 0-120 15474.2 100.00

120-125 0.1 0.00 0-125 15474.3 100.00

125-130 0.0 0.00 0-130 15474.3 100.00

130-135 0.0 0.00 0-135 15474.3 100.00

135-140 0.0 0.00 0-140 15474.3 100.00

140-145 0.0 0.00 0-145 15474.3 100.00

145-150 0.0 0.00 0-150 15474.3 100.00

150-155 0.0 0.00 0-155 15474.3 100.00

155-160 0.0 0.00 0-160 15474.3 100.00

160-165 0.0 0.00 0-165 15474.3 100.00

165-170 0.0 0.00 0-170 15474.3 100.00

170-175 0.0 0.00 0-175 15474.3 100.00

175-180 0.0 0.00 0-180 15474.3 100.00

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ140815503-10 Page 12 of 12 The NVLAP Lab Code is 200707-0.

[Additional Test]

Test Item Test Voltage (V) Frequency (Hz) Test Result

Power Factor: 305 60 0.901

Total Harmonic Distortion: 120 60 4.89%

Total Harmonic Distortion: 305 60 21.52%

Off State Power (W): 120 60 0.0

6. Product Photo

***********END OF REPORT***********