IES LM-79-08 - EiKO...IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St...

13
STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St Shawnee, KS 66227 Test Model: LED-DKD-13W830-DIM-G5 Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution Test Engineer: Daniel Duan Report Number: RSZ150812522-10A1 Test Date: 2015-08-18 Report Date: 2016-01-25 Reviewed By: Jeanne Han/Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0.

Transcript of IES LM-79-08 - EiKO...IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St...

  • STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

    IES LM-79-08 MEASUREMENT AND TEST REPORT

    For

    EiKO Global, LLC23220 W 84th St Shawnee, KS 66227

    Test Model: LED-DKD-13W830-DIM-G5

    Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution

    Test Engineer: Daniel Duan

    Report Number: RSZ150812522-10A1

    Test Date: 2015-08-18

    Report Date: 2016-01-25

    Reviewed By: Jeanne Han/Safety Manager

    Prepared By:

    Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008

    Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

    Accreditation: The NVLAP Lab Code is 200707-0.

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 2 of 13 The NVLAP Lab Code is 200707-0.

    1. Product Description

    General Information:

    One sample was received on 2015-08-12 and used for testing.

    Model Tested:

    Manufacturer:

    Product Designation:

    Burning Time Before Test:

    Rated Values:

    Rated Voltage/Frequency:

    Rated Power:

    Nominal CCT:

    Auxiliary Equipment:

    LED-DKD-13W830-DIM-G5

    EiKO Global, LLC

    SSL downlight retrofit & Ceiling-mounted luminaire

    0 hour(For New Products)

    AC 120V 60Hz

    13W

    3000K

    H99TAT, Cooper Lighting,LLC (The can was only used in goniophotometer)

    2. Standards Used

    IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

    3. Description of Test Equipment

    Device Manufacture Model No Serial No Test Range Calibration date Calibration

    due date Integrating

    Sphere SENSING SPR-600 S09008 25 50 2015-03-25 2016-03-24

    Spectral photometer SENSING SPR3000 90902027 350nm 800nm 2015-03-25 2016-03-24

    Power Meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/600 V 2015-03-05 2016-03-04

    AC Power Supply ALL Power APW-105N 970663 220V±10% 50HZ 2015-03-05 2016-03-04

    Standard Light Source EVERFINE D204 01331191 24V/100W 2015-08-27 2016-08-26

    Thermal Meter SENSING N/A N/A 25 50 2015-03-05 2016-03-04

    DC Power Supply ITECH IT6154

    0061 0417 6471 0010 19 0~32V 2015-03-05 2016-03-04

    AC Power Supply EVERFINE

    VPS1030 PWM 1012017 0-150V 0-300V 2015-03-05 2016-03-04

    DC Power Supply EVERFINE WY12010 1009009 30V/5A 2015-03-05 2016-03-04

    Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2015-03-05 2016-03-04

    Goniophotometer EVERFINE GO-R5000 YG108492N10120001 1600mm,3000W/10A 2015-03-20 2016-03-19

    Wireless Remote Sensor N/A 433MHz N/A 0 ~50 ;-20 ~60 2015-03-24 2016-03-23

    Standard Light Source EVERFINE D908 1012003 N/A 2015-09-08 2016-09-07

    Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 3 of 13 The NVLAP Lab Code is 200707-0.

    4. Test Method

    Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of thesample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

    Integrating Sphere System

    The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement.

    4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

    The uncertainty of the light output (luminous flux) measurements is U=2.3% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1(K=2) , at the 95% confidence level.

    The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

    Goniophotometer System

    The luminaire was tested in a can.

    The goniophotometer system is calibrated by standard light source before measurement.

    Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report.

    The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 4 of 13 The NVLAP Lab Code is 200707-0.

    5. Test Result

    [Integrating Sphere System]

    Total operating time for integrating sphere test: 1.0 hours

    Test orientation: Downward

    Electrical Measurement

    Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

    120.02 60.0 0.1116 12.971 0.968

    Photometric Measurement

    Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

    1032.35 3.237 79.589 3035 -2.01E-03

    Chromaticity Coordinate

    x y u v u' v'

    0.4536 0.4038 0.2615 0.3492 0.2615 0.5238

    Color Rendering Index

    Ra 82.7

    R1 R2 R3 R4 81 92 95 80

    R5 R6 R7 R8 82 91 81 58

    R9 R10 R11 R12 10 82 80 78

    R13 R14 R15 84 98 74

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 5 of 13 The NVLAP Lab Code is 200707-0.

    Relative Spectral Power Distribution

    nm mW

    nm mW

    nm mW

    nm mW

    nm mW

    380 1.305E-03 465 1.974E-02 550 5.333E-02 635 7.921E-02 720 9.547E-03

    385 8.109E-04 470 1.593E-02 555 5.697E-02 640 7.408E-02 725 8.046E-03

    390 5.407E-04 475 1.378E-02 560 6.100E-02 645 6.762E-02 730 6.915E-03

    395 3.250E-04 480 1.484E-02 565 6.533E-02 650 6.149E-02 735 5.915E-03

    400 3.304E-04 485 1.742E-02 570 7.061E-02 655 5.549E-02 740 5.063E-03

    405 3.875E-04 490 2.039E-02 575 7.525E-02 660 4.957E-02 745 4.243E-03

    410 6.478E-04 495 2.448E-02 580 8.013E-02 665 4.448E-02 750 3.876E-03

    415 1.124E-03 500 2.832E-02 585 8.536E-02 670 3.903E-02 755 3.276E-03

    420 2.297E-03 505 3.146E-02 590 9.025E-02 675 3.429E-02 760 2.906E-03

    425 4.487E-03 510 3.419E-02 595 9.344E-02 680 2.968E-02 765 2.379E-03

    430 8.277E-03 515 3.584E-02 600 9.627E-02 685 2.587E-02 770 2.365E-03

    435 1.419E-02 520 3.796E-02 605 9.719E-02 690 2.275E-02 775 1.880E-03

    440 2.336E-02 525 3.964E-02 610 9.639E-02 695 1.973E-02 780 1.624E-03

    445 3.645E-02 530 4.205E-02 615 9.548E-02 700 1.702E-02 785 1.454E-03

    450 4.231E-02 535 4.424E-02 620 9.216E-02 705 1.468E-02 790 1.297E-03

    455 3.402E-02 540 4.619E-02 625 8.907E-02 710 1.259E-02 795 1.180E-03

    460 2.368E-02 545 4.985E-02 630 8.421E-02 715 1.095E-02 800 9.553E-04

    0.0

    0.2

    0.4

    0.6

    0.8

    1.0

    1.2

    380 440 500 560 620 680 740 800

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 6 of 13 The NVLAP Lab Code is 200707-0.

    CIE 1931 x y Chromaticity Diagram

    7-Step & 4-Step Chromaticity Quadrangles

    0

    0.1

    0.2

    0.3

    0.4

    0.5

    0.6

    0.7

    0.8

    0.9

    0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

    0.30

    0.35

    0.40

    0.45

    0.30 0.35 0.40 0.45 0.50

    sample

    7-STEP 2700K

    7-STEP 3000K

    7-STEP 3500K

    7-STEP 4000K

    7-STEP 4500K

    7-STEP 5000K

    7-STEP 5700K

    7-STEP 6500K

    4-STEP 2700K

    4-STEP 3000K

    4-STEP 3500K

    4-STEP 4000K

    4-STEP 5000K

    4-STEP 6500K

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 7 of 13 The NVLAP Lab Code is 200707-0.

    [Goniophotometer System]

    Total operating time for luminous intensity distribution: 1.0 hours

    Test orientation: Downward

    Electrical Measurement

    Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

    120.1 60.0 0.1122 12.95 0.9613

    Photometric Measurement

    Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)

    986.399 76.17 359.6 1.21 1.21

    Luminous Intensity Distribution

    C0/180 C45/225 C90/270 C135/315 AVG.

    Beam Angle (50% Imax): 104.2 104.1 104.0 104.1 104.1

    Field Angle (10% Imax): 167.2 167.0 166.9 167.1 167.1

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 8 of 13 The NVLAP Lab Code is 200707-0.

    Luminous Intensity (cd) Distribution Data C 0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

    0.0° 360 360 360 360 360 360 360 360 5.0° 357 357 357 357 357 357 357 358

    10.0° 351 351 350 350 350 351 351 352 15.0° 341 340 340 340 340 340 341 341 20.0° 327 326 326 325 326 326 327 328 25.0° 309 309 308 308 308 308 309 310 30.0° 289 288 288 287 287 288 289 290 35.0° 267 266 265 265 264 265 266 268 40.0° 242 241 240 240 240 241 242 243 45.0° 217 216 215 214 214 215 216 217 50.0° 191 190 189 188 188 188 190 191 55.0° 165 164 163 162 162 162 163 165 60.0° 139 138 137 136 136 137 138 139 65.0° 114 113 112 112 112 112 113 114 70.0° 91 90 89 88 88 88 89 90 75.0° 69 68 67 67 66 67 67 68 80.0° 49 48 47 47 47 47 47 48 85.0° 32 31 31 31 30 30 31 31 90.0° 19 18 18 18 17 17 18 18 95.0° 9 9 9 9 9 9 9 9 100.0° 4 4 3 3 3 3 3 4 105.0° 0 0 0 0 0 0 0 0 110.0° 0 0 0 0 0 0 0 0 115.0° 0 0 0 0 0 0 0 0 120.0° 0 0 0 0 0 0 0 0 125.0° 0 0 0 0 0 0 0 0 130.0° 0 0 0 0 0 0 0 0 135.0° 0 0 0 0 0 0 0 0 140.0° 0 0 0 0 0 0 0 0 145.0° 0 0 0 0 0 0 0 0 150.0° 1 1 1 1 1 1 1 1 155.0° 1 1 1 1 1 1 1 1 160.0° 1 1 1 1 1 1 1 1 165.0° 1 1 1 1 1 1 1 1 170.0° 1 1 1 1 1 1 1 1 175.0° 0 1 1 0 0 0 1 1 180.0° 0 0 0 0 0 0 0 0

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 9 of 13 The NVLAP Lab Code is 200707-0.

    Luminous Intensity (cd) Distribution Data (cont.) C 180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

    0.0° 360 360 360 360 360 360 360 360 5.0° 358 358 358 358 358 358 358 357 10.0° 351 352 352 352 352 352 351 351 15.0° 342 342 342 342 342 342 341 341 20.0° 328 328 329 329 329 328 328 327 25.0° 310 311 312 312 312 311 310 309 30.0° 290 291 292 292 292 291 290 289 35.0° 268 269 269 270 269 269 268 267 40.0° 243 244 245 245 245 244 243 242 45.0° 217 219 219 219 219 219 218 217 50.0° 191 192 193 193 193 192 192 191 55.0° 165 166 166 167 166 166 165 165 60.0° 139 140 141 141 141 141 140 139 65.0° 113 114 115 115 115 115 114 114 70.0° 90 90 91 91 91 91 91 90 75.0° 68 68 69 69 69 69 69 68 80.0° 48 48 49 49 49 49 49 49 85.0° 31 32 32 32 32 32 32 32 90.0° 18 18 18 18 18 19 19 18 95.0° 9 9 9 9 9 9 9 9 100.0° 4 4 4 4 4 4 4 4 105.0° 0 0 0 0 0 0 0 0 110.0° 0 0 0 0 0 0 0 0 115.0° 0 0 0 0 0 0 0 0 120.0° 0 0 0 0 0 0 0 0 125.0° 0 0 0 0 0 0 0 0 130.0° 0 0 0 0 0 0 0 0 135.0° 0 0 0 0 0 0 0 0 140.0° 0 0 0 0 0 0 0 0 145.0° 0 0 0 0 0 0 0 0 150.0° 1 0 0 1 0 1 1 1 155.0° 1 1 1 1 1 1 1 1 160.0° 1 1 1 1 1 1 1 1 165.0° 1 1 1 0 1 1 1 1 170.0° 0 0 1 1 1 1 1 1 175.0° 0 0 0 1 1 1 0 0 180.0° 0 0 0 0 0 0 0 0

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 10 of 13 The NVLAP Lab Code is 200707-0.

    Average Area Illumination Figure

    Height (m) Diameter (cm) Eavg(lx) Emax(lx)

    0.5 128.2 472.9 1439.0

    1.0 256.4 118.2 359.7

    1.5 384.7 52.6 159.9

    2.0 512.9 29.6 89.9

    2.5 641.1 18.9 57.6

    3.0 769.3 13.1 40.0

    3.5 897.6 9.6 29.4

    4.0 1025.8 7.4 22.5

    4.5 1154.0 5.8 17.8

    5.0 1282.2 4.7 14.4

    Angle: 104.10°. Flux out: 654.1 lm.

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 11 of 13 The NVLAP Lab Code is 200707-0.

    Zonal Lumen Density Measurement

    Deg Flux (lm) % Deg Flux (lm) %

    0-5 8.6 0.87 0-5 8.6 0.87

    5-10 25.4 2.57 0-10 33.9 3.44 10-15 41.1 4.16 0-15 75.0 7.60

    15-20 55.1 5.59 0-20 130.1 13.19

    20-25 66.8 6.77 0-25 196.9 19.96 25-30 75.9 7.69 0-30 272.8 27.65

    30-35 82.0 8.31 0-35 354.7 35.96

    35-40 85.0 8.62 0-40 439.7 44.58 40-45 85.0 8.62 0-45 524.7 53.20

    45-50 82.3 8.34 0-50 607.1 61.54

    50-55 77.2 7.83 0-55 684.2 69.37 55-60 70.0 7.09 0-60 754.2 76.46

    60-65 61.2 6.20 0-65 815.4 82.66

    65-70 51.4 5.22 0-70 866.8 87.88 70-75 41.2 4.17 0-75 908.0 92.05

    75-80 31.0 3.14 0-80 938.9 95.19

    80-85 21.4 2.17 0-85 960.4 97.36 85-90 13.4 1.36 0-90 973.7 98.72

    90-95 7.3 0.73 0-95 981.0 99.45

    95-100 3.3 0.33 0-100 984.2 99.78 100-105 0.9 0.09 0-105 985.1 99.87

    105-110 0.0 0.00 0-110 985.2 99.87

    110-115 0.0 0.01 0-115 985.2 99.88 115-120 0.1 0.00 0-120 985.2 99.88

    120-125 0.1 0.01 0-125 985.3 99.89

    125-130 0.1 0.01 0-130 985.4 99.90 130-135 0.1 0.00 0-135 985.5 99.90

    135-140 0.1 0.02 0-140 985.6 99.92

    140-145 0.1 0.01 0-145 985.7 99.93 145-150 0.1 0.01 0-150 985.8 99.94

    150-155 0.2 0.02 0-155 986.0 99.96

    155-160 0.2 0.01 0-160 986.1 99.97 160-165 0.1 0.02 0-165 986.3 99.99

    165-170 0.1 0.00 0-170 986.3 99.99

    170-175 0.0 0.01 0-175 986.4 100.00 175-180 0.0 0.00 0-180 986.4 100.00

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 12 of 13 The NVLAP Lab Code is 200707-0.

    6. EUT Photo for Ceiling mount

  • Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

    Free Trade Zone Shenzhen, Guangdong, China

    Report No. RSZ150812522-10A1 Page 13 of 13 The NVLAP Lab Code is 200707-0.

    EUT Photo for Recessed mount

    ***********END OF REPORT***********