IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp....

13
STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St Shawnee, KS 66227 Test Model: LED7WPAR20/FL/830K-DIM-G6 Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, Spatial Non- uniformity of Chromaticity Test Engineer: Daniel Duan Report Number: RSZ141223518-10A1 Test Date: 2014-12-30 to 2015-01-06 Report Date: 2015-09-09 Reviewed By: Jeanne Han/Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0.

Transcript of IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp....

Page 1: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

IES LM-79-08 MEASUREMENT AND TEST REPORT

For

EiKO Global, LLC23220 W 84th St Shawnee, KS 66227

Test Model: LED7WPAR20/FL/830K-DIM-G6

Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution, Spatial Non-uniformity of Chromaticity

Test Engineer: Daniel Duan

Report Number: RSZ141223518-10A1

Test Date: 2014-12-30 to 2015-01-06

Report Date: 2015-09-09

Reviewed By: Jeanne Han/Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008

Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

Accreditation: The NVLAP Lab Code is 200707-0.

Page 2: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 2 of 13 The NVLAP Lab Code is 200707-0.

1. Product Description

General Information:

Two samples were received on 2014-12-23. One was tested in integrating sphere and the other was tested in goniophotometer.

Model Tested:

Manufacturer:

Product Designation:

Burning Time Before Test:

Rated Values:

Rated Voltage/Frequency:

Rated Power:

Nominal CCT:

LED7WPAR20/FL/830K-DIM-G6

EiKO Global, LLC

Directional LED Lamp

0 hour(For New Products)

AC 120 V 60Hz

7W

3000K

2. Standards Used

IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration

date Calibration

due date Integrating Sphere SENSING N/A N/A 1.5meter 2015-03-05 2016-03-05

Power Meter SENSING UI2008 908735 10.0-600.0V 2015-03-05 2016-03-05

Spectral photometer SENSING SPR3000 s0902024 350nm 800nm 2015-03-05 2016-03-05

AC Power Supply ALL Power APW-105N 970663 0V-300V 50-400Hz 2015-03-05 2016-03-05

Standard Light Source EVERFINE D204 LSD090808 N/A 2015-08-05 2016-08-05

Thermal Meter SENSING N/A N/A 20~30 2015-03-05 2016-03-05

DC Power Supply ITECH IT6154 0061 0417 6471 0010 19 0~32V 2015-03-05 2016-03-05

AC Power Supply EVERFINE VPS1030 PWM 1012017 0-150V 0-300V 2015-03-05 2016-03-05

DC Power Supply EVERFINE WY12010 1009009 30V/5A 2015-03-05 2016-03-05

Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2015-03-05 2016-03-05

Goniophotometer EVERFINE GO-R5000 YG108492N10120001 1600mm,3000W/10A 2015-03-20 2016-03-20

Thermal Meter Victor VC230 EE091 0~40 0~90% 2013-04-01 2016-03-31

Standard Light Source EVERFINE D908 1012003 N/A 2015-05-15 2016-05-14 Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

Page 3: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 3 of 13 The NVLAP Lab Code is 200707-0.

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=2.3% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1(K=2) , at the 95% confidence level.

The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

Page 4: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 4 of 13 The NVLAP Lab Code is 200707-0.

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.0 hour

Test orientation: Base up

Electrical Measurement

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

120.0 60.0 0.06 6.7 0.934

Photometric Measurement

Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

590.821 1.519 88.182 3033 5.80E-04

Chromaticity Coordinate

x y u v u' v'

0.4354 0.4050 0.2492 0.3477 0.2492 0.5215

Color Rendering Index

Ra 81.9

R1 R2 R3 R4 80 89 97 80

R5 R6 R7 R8 80 86 84 60

R9 R10 R11 R12 8 75 79 70

R13 R14 R15 82 98 73

Page 5: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 5 of 13 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution

nm mW

nm mW

nm mW

nm mW

nm mW

380 2.496E-04 465 1.173E-02 550 3.155E-02 635 3.813E-02 720 5.124E-03

385 1.405E-04 470 9.699E-03 555 3.353E-02 640 3.544E-02 725 4.422E-03

390 1.049E-04 475 8.499E-03 560 3.526E-02 645 3.271E-02 730 3.815E-03

395 7.751E-05 480 8.624E-03 565 3.718E-02 650 3.003E-02 735 3.295E-03

400 1.013E-04 485 9.856E-03 570 3.927E-02 655 2.702E-02 740 2.869E-03

405 2.129E-04 490 1.159E-02 575 4.170E-02 660 2.424E-02 745 2.489E-03

410 5.133E-04 495 1.371E-02 580 4.376E-02 665 2.169E-02 750 2.221E-03

415 1.135E-03 500 1.607E-02 585 4.534E-02 670 1.947E-02 755 1.931E-03

420 2.205E-03 505 1.816E-02 590 4.666E-02 675 1.732E-02 760 1.717E-03

425 4.050E-03 510 1.993E-02 595 4.803E-02 680 1.516E-02 765 1.504E-03

430 6.795E-03 515 2.128E-02 600 4.878E-02 685 1.330E-02 770 1.358E-03

435 1.043E-02 520 2.265E-02 605 4.868E-02 690 1.172E-02 775 1.197E-03

440 1.511E-02 525 2.406E-02 610 4.798E-02 695 1.028E-02 780 1.073E-03

445 2.081E-02 530 2.547E-02 615 4.689E-02 700 8.903E-03 785 9.528E-04

450 2.397E-02 535 2.661E-02 620 4.533E-02 705 7.678E-03 790 8.885E-04

455 2.048E-02 540 2.802E-02 625 4.342E-02 710 6.642E-03 795 8.188E-04

460 1.499E-02 545 2.961E-02 630 4.094E-02 715 5.788E-03 800 7.441E-04

0.0

0.2

0.4

0.6

0.8

1.0

1.2

380 440 500 560 620 680 740 800

Page 6: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 6 of 13 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram

7-Step & 4-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50

sample

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

4-STEP 2700K

4-STEP 3000K

4-STEP 3500K

4-STEP 4000K

4-STEP 5000K

4-STEP 6500K

Page 7: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 7 of 13 The NVLAP Lab Code is 200707-0.

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.0 hour

Test orientation: Base up

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

120.0 60.0 0.0606 6.789 0.9339

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)

657 96.77 1206 0.71 0.63

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 43.4 42.7 41.1 40.9 42.03

Field Angle (10% Imax): 70.3 68.1 63.3 65.9 66.90

Page 8: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 8 of 13 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data C 0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 1181 1181 1181 1181 1181 1181 1181 1181 5.0° 1135 1141 1169 1196 1198 1184 1145 1095

10.0° 1013 1019 1056 1091 1080 1058 1002 957 15.0° 932 946 928 897 881 837 794 805 20.0° 737 747 714 652 611 572 547 559 25.0° 481 486 430 398 330 306 329 331 30.0° 277 278 236 193 147 138 156 177 35.0° 145 138 112 80 56 57 68 92 40.0° 72 65 60 38 27 27 34 52 45.0° 40 35 37 24 20 20 23 32 50.0° 27 25 26 19 17 17 18 24 55.0° 21 20 21 16 15 15 16 19 60.0° 17 17 17 14 13 13 13 15 65.0° 13 13 13 11 11 10 10 11 70.0° 10 10 10 9 8 8 8 8 75.0° 7 7 7 6 6 6 5 5 80.0° 4 4 4 4 4 3 3 3 85.0° 2 2 2 2 2 2 2 2 90.0° 1 1 1 1 1 1 1 1 95.0° 1 1 1 0 0 0 1 0 100.0° 0 1 1 0 0 0 1 1 105.0° 0 0 0 0 0 0 0 0 110.0° 0 0 0 0 0 0 0 0 115.0° 0 0 0 0 0 0 0 0 120.0° 0 0 0 0 0 0 0 0 125.0° 0 0 0 0 0 0 0 0 130.0° 0 0 0 0 0 0 0 0 135.0° 0 0 0 0 0 0 0 0 140.0° 0 0 0 0 0 0 0 0 145.0° 0 0 0 0 0 0 0 0 150.0° 0 0 0 0 0 0 0 0 155.0° 0 0 0 0 0 0 0 0 160.0° 0 0 0 0 0 0 0 0 165.0° 0 0 0 0 0 0 0 0 170.0° 0 0 0 0 0 0 0 0 175.0° 0 0 0 0 0 0 0 0 180.0° 0 0 0 0 0 0 0 0

Page 9: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 9 of 13 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.) C 180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 1181 1181 1181 1181 1181 1181 1181 1181 5.0° 1068 1063 1086 1121 1162 1195 1199 1184 10.0° 968 986 1005 1024 1075 1128 1132 1092 15.0° 851 872 882 873 885 929 940 941 20.0° 625 656 637 634 648 683 706 734 25.0° 391 406 379 386 387 395 454 466 30.0° 209 214 200 192 175 183 236 265 35.0° 98 98 96 85 70 73 106 146 40.0° 47 45 52 41 33 34 49 75 45.0° 29 27 33 25 21 23 28 45 50.0° 22 21 25 19 17 19 20 31 55.0° 18 18 20 17 15 16 17 24 60.0° 14 14 16 14 13 14 15 18 65.0° 11 11 12 11 11 11 12 14 70.0° 8 8 9 9 9 9 9 10 75.0° 6 6 6 6 6 6 7 7 80.0° 3 3 4 4 4 4 4 4 85.0° 2 2 2 2 2 2 2 3 90.0° 1 1 1 1 1 1 1 1 95.0° 0 0 0 0 0 1 1 1 100.0° 0 0 0 0 0 0 0 0 105.0° 0 0 0 0 0 0 0 0 110.0° 0 0 0 0 0 0 0 0 115.0° 0 0 0 0 0 0 0 0 120.0° 0 0 0 0 0 0 0 0 125.0° 0 0 0 0 0 0 0 0 130.0° 0 0 0 0 0 0 0 0 135.0° 0 0 0 0 0 0 0 0 140.0° 0 0 0 0 0 0 0 0 145.0° 0 0 0 0 0 0 0 0 150.0° 0 0 0 0 0 0 0 0 155.0° 0 0 0 0 0 0 0 0 160.0° 0 0 0 0 0 0 0 0 165.0° 0 0 0 0 0 0 0 0 170.0° 0 0 0 0 0 0 0 0 175.0° 0 0 0 0 0 0 0 0 180.0° 0 0 0 0 0 0 0 0

Page 10: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 10 of 13 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure

Height (m) Diameter (cm) Eavg(lx) Emax(lx)

0.5 38.4 3212.0 4813.0

1.0 76.8 803.1 1203.0

1.5 115.2 356.9 534.8

2.0 153.5 200.8 300.8

2.5 191.9 128.5 192.5

3.0 230.3 89.2 133.7

3.5 268.7 65.6 98.2

4.0 307.1 50.2 75.2

4.5 345.5 39.7 59.4

5.0 383.9 32.1 48.1

Angle: 42.00°. Flux out: 371.8 lm.

Page 11: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 11 of 13 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement

Deg Flux (lm) %

Deg Flux (lm) %

0-5 27.8 4.24 0-5 27.8 4.24

5-10 78.2 11.90 0-10 106.1 16.14 10-15 114.5 17.44 0-15 220.6 33.58

15-20 127.1 19.34 0-20 347.7 52.92

20-25 108.8 16.55 0-25 456.4 69.47 25-30 73.9 11.25 0-30 530.3 80.72

30-35 42.1 6.41 0-35 572.5 87.13

35-40 22.4 3.41 0-40 594.9 90.54 40-45 13.5 2.06 0-45 608.4 92.60

45-50 10.0 1.52 0-50 618.4 94.12

50-55 8.6 1.30 0-55 626.9 95.42 55-60 7.6 1.15 0-60 634.5 96.57

60-65 6.4 0.98 0-65 640.9 97.55

65-70 5.2 0.79 0-70 646.1 98.34 70-75 3.9 0.59 0-75 650.0 98.93

75-80 2.6 0.40 0-80 652.6 99.33

80-85 1.6 0.23 0-85 654.1 99.56 85-90 0.7 0.11 0-90 654.9 99.67

90-95 0.3 0.05 0-95 655.2 99.72

95-100 0.3 0.04 0-100 655.5 99.76 100-105 0.3 0.04 0-105 655.7 99.80

105-110 0.2 0.04 0-110 655.9 99.84

110-115 0.2 0.03 0-115 656.2 99.87 115-120 0.2 0.03 0-120 656.3 99.90

120-125 0.1 0.02 0-125 656.5 99.92

125-130 0.1 0.02 0-130 656.6 99.94 130-135 0.1 0.01 0-135 656.7 99.95

135-140 0.1 0.01 0-140 656.8 99.96

140-145 0.1 0.01 0-145 656.8 99.97 145-150 0.0 0.01 0-150 656.9 99.98

150-155 0.0 0.01 0-155 656.9 99.99

155-160 0.0 0.00 0-160 656.9 99.99 160-165 0.0 0.01 0-165 657.0 100.00

165-170 0.0 0.00 0-170 657.0 100.00

170-175 0.0 0.00 0-175 657.0 100.00 175-180 0.0 0.00 0-180 657.0 100.00

Page 12: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 12 of 13 The NVLAP Lab Code is 200707-0.

Color Spatial Uniformity Average Weighted

u': 0.2479, v': 0.5216 γ \ C0-180 u’ v’ Du’v’ γ \ C90-270 u’ v’ Du’v’

-30 0.2477 0.5219 0.0004 -30 0.2470 0.5218 0.0010 -25 0.2483 0.5221 0.0007 -25 0.2477 0.5223 0.0008 -20 0.2481 0.5222 0.0007 -20 0.2483 0.5228 0.0013 -15 0.2480 0.5219 0.0003 -15 0.2483 0.5225 0.0010 -10 0.2485 0.5217 0.0006 -10 0.2484 0.5224 0.0009 -5 0.2482 0.5213 0.0003 -5 0.2480 0.5215 0.0001 0 0.2481 0.5211 0.0005 0 0.2480 0.5209 0.0007 5 0.2477 0.5205 0.0010 5 0.2478 0.5205 0.0011

10 0.2478 0.5208 0.0008 10 0.2478 0.5209 0.0007 15 0.2478 0.5212 0.0004 15 0.2482 0.5216 0.0003 20 0.2476 0.5212 0.0005 20 0.2481 0.5215 0.0002 25 0.2472 0.5210 0.0009 25 0.2477 0.5218 0.0003 30 0.2463 0.5208 0.0018 30 0.2475 0.5219 0.0005

Page 13: IES LM-79-08 - EiKO - All Categories · PDF fileBay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ141223518-10A1 Page 13 of 13 The NVLAP Lab Code is 200707-0.

6. Product Photo