IDU Installation Guide 2007-11

70
FibeAir ® 1500P FibeAir ® IP-MAX FibeAir ® IP-MAX 2 IDU Installation Guide Part ID: BM-0127-0 Doc ID: DOC-00016217 Rev a.02 November 2007

Transcript of IDU Installation Guide 2007-11

Page 1: IDU Installation Guide 2007-11

FibeAir® 1500P FibeAir® IP-MAX FibeAir® IP-MAX2

IDU Installation

Guide

Part ID: BM-0127-0 Doc ID: DOC-00016217 Rev a.02

November 2007

Page 2: IDU Installation Guide 2007-11

Notice

This document contains information that is proprietary to Ceragon Networks Ltd. No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd. This document is provided as is, without warranty of any kind.

Registered TradeMarks

Ceragon Networks® is a registered trademark of Ceragon Networks Ltd. FibeAir® is a registered trademark of Ceragon Networks Ltd. CeraView® is a registered trademark of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.

TradeMarks

CeraMapTM, PolyViewTM, EncryptAirTM, ConfigAirTM, CeraMonTM, EtherAirTM, and MicroWave FiberTM, are trademarks of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.

Statement of Conditions

The information contained in this document is subject to change without notice. Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it.

Information to User

Any changes or modifications of equipment not expressly approved by the manufacturer could void the user’s authority to operate the equipment and the warranty for such equipment.

Copyright © 2007 by Ceragon Networks Ltd. All rights reserved.

Corporate Headquarters: Ceragon Networks Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719, Israel Tel: 972-3-645-5733 Fax: 972-3-645-5499 Email: [email protected] www.ceragon.com

European Headquarters: Ceragon Networks (UK) Ltd. 4 Oak Tree Park, Burnt Meadow Road North Moons Moat, Redditch, Worcestershire B98 9NZ, UK Tel: 44-(0)-1527-591900 Fax: 44-(0)-1527-591903 Email: [email protected]

North American Headquarters: Ceragon Networks Inc. 10 Forest Avenue, Paramus, NJ 07652, USA Tel: 1-201-845-6955 Toll Free: 1-877-FIBEAIR Fax: 1-201-845-5665 Email: [email protected]

APAC Headquarters Ceragon Networks (HK) Ltd. Singapore RO Level 34 Centennial Tower 3 Temasek Avenue Singapore 039190 Tel - + 65 6549 7886 Fax: +65 6549 7011

Page 3: IDU Installation Guide 2007-11

Contents

Chapter 1: Installation................................................................................... 1-1

General................................................................................................................................ 1-1

Site Requirements.............................................................................................................. 1-1

Pre-Installation ................................................................................................................... 1-1

Unpacking Equipment at the Site..................................................................................... 1-2

Installation Requirements ................................................................................................. 1-2

FibeAir 1500P Description ................................................................................................ 1-4

FibeAir IP-MAX Description .............................................................................................. 1-7

FibeAir IP-MAX2 Description............................................................................................. 1-8

Installing the IDU in a Rack............................................................................................... 1-9

Grounding the IDU ........................................................................................................... 1-11

Connecting the IDU.......................................................................................................... 1-13

Chapter 2: Initial System Setup.................................................................... 2-1

General................................................................................................................................ 2-1

Initial Setup using the Craft Terminal .............................................................................. 2-2

Additional Setup using CeraView..................................................................................... 2-5

Connecting Line Interfaces............................................................................................. 2-12

Chapter 3: Acceptance and Commissioning Procedures.......................... 3-1

General................................................................................................................................ 3-1

Site Acceptance Procedure .............................................................................................. 3-2

1+0 Commissioning Procedure ........................................................................................ 3-7

1+1 Commissioning Procedure ........................................................................................ 3-9

2+0 XPIC Commissioning Procedure............................................................................. 3-12

FibeAir 1500P/IP-MAX/IP-MAX2 Commissioning Log................................................... 3-15

Appendix A: Line Interfaces and Cables .....................................................A-1

Appendix B: Connector Pin-Outs.................................................................B-1

Appendix C: Protection Kits .........................................................................C-1

Appendix D PPP/SLIP Driver Installation ....................................................D-1

Page 4: IDU Installation Guide 2007-11

Safety Precautions & Declared Material

Fiber Optic Line Precautions

Before turning on the equipment, make sure that the fiber optic cable is intact and is connected to the transmitter.

Do not attempt to adjust the laser drive current.

Do not use broken or non-terminated fiber optic cables/connectors or look straight at the laser beam.

ATTENTION: The laser beam is invisible!

The use of optical devices with the equipment will increase eye hazard.

CLASS 1 LASER PRODUCT

Complies with IEC 60 825-1:1993 + A1:1997 + A2:2001, and EN 60825-1:1994 + A1:1996 + A2:2001

General Equipment Precautions

Use of controls, adjustments, or performing procedures other than those specified herein, may result in hazardous radiation exposure.

When working with a FibeAir IDU, note the following risk of electric shock and energy hazard: Diconnecting one power supply disconnects only one power supply module. To isolate the unit completely, disconnect all power supplies.

Machine noise information order - 3. GPSGV, the highest sound pressure level amounts to 70 dB (A) or less, in accordance with ISO EN 7779.

Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger gemäss EN ISO 7779.

Bruit de machine d’ordre - 3. GPSGV, le plus haut niveau de pression sonore s'élève à 70 dB (A) au maximum, dans le respect de la norme ISO EN 7779.

!!

!!

!!

!!

!!

!!

!!

Page 5: IDU Installation Guide 2007-11

Safety Precautions & Declared Material (continued)

Static electricity may cause body harm, as well as harm to electronic components inside the device.

Anyone responsible for the installation or maintainance of the FibeAir IDU must use an ESD Wrist Strap.

ESD protection measures must be observed when touching the IDU.

To prevent damage, before touching components inside the device, all electrostatic must be discharged from both personnel and tools.

RoHS Compliance Declaration

电子信息产品有毒有害物质申明 Electronic Information Products Declaration of Hazardous/Toxic Substances

危害物质 Hazardous Substance

成分名称 Component 铅

Lead (Pb)

汞 Mercury

(Hg)

镉 Cadmium

(Cd)

六价铬 Hexavalent

Chromium (Cr VI)

多溴联苯 Polybrominated Biphenyls (PBB)

多溴二苯醚 Polybrominated Diphenyl Ethers

(PBDE)

单板 / 电路模块 PCB/Circuit Modules

Comply Comply Comply Comply Comply Comply

结构件 Mechanical Parts

Comply Comply Comply Comply Comply Comply

电缆 Cables

Comply Comply Comply Comply Comply Comply

Page 6: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 Installation Guide 1-1

Chapter 1: Installation

General This chapter provides instructions for the installation of the FibeAir 1500P/IP-MAX/IP-MAX2 IDU at the customer site.

Site Requirements Must be located indoors.

The environment temperature must be between -5 C and +45 C.

Easily accessible, but only by authorized personnel.

Available power source of -48 VDC, and the site must comply with National Electric Code (NEC) standards.

Available management connection (Ethernet or dial-up).

No more than 300 m from ODU location.

In addition, since the IDU will be connected to the ODU, when considering a site, it is important to check for current and future obstacles on the roof or tower. Possible future obstacles may include trees, new buildings, window cleaners on the roof, snow that may accumulate in front of the antenna, etc. The site should be accessible to certified personnel only.

Note about Antenna Location: As with any type of construction, a local permit may be required before installing an antenna. It is the owner’s responsibility to obtain any and all permits.

Pre-Installation

Packing

The equipment is packed at the factory, and sealed moisture-absorbing bags are inserted.

Transportation

The equipment is prepared for public transportation. The cargo must be kept dry during transportation, in accordance with ETS 300 019-1-2, Class 2.3.

It is recommended to transport the equipment to the installation site in its original packing case.

If intermediate storage is required, the packed equipment must be stored in dry and cool conditions and out of direct sunlight, in accordance with ETS 300 019-1-1, Class 1.2.

Page 7: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-2

Inspection

Check the packing lists, and ensure that the correct part numbers and quantities of components arrived.

Unpacking Equipment at the Site A single FibeAir system (1+0) is shipped in 5 crates. Upon delivery, make sure that the following items are included:

Two indoor units and accessories

Two outdoor units

One CD with CeraView management software (if ordered) and a CeraView user guide.

Unpack the contents and check for damaged or missing parts. If any part is damaged or missing, contact your local distributor.

Installation Requirements

Required Tools

The following tools are required to install the IDU:

Philips screwdriver (for mounting the IDU to the rack and grounding screw)

Flathead small screwdriver (for PSU connector and to unlock the IDC/IDMs from the chassis)

Sharp cutting knife (for wire stripping)

Crimping tool for ground cable lug crimping (optional: if alternative grounding cable is used).

Cables

In addition to the tools mentioned above, the cables necessary for IDU installation, and their pin-outs, can be found in the following sections in this guide:

Appendix A: Line Interfaces and Cables

Appendix B: Connector Pin-Outs

Page 8: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-3

Requirements for North America

Restricted Access Area: DC powered equipment should only be installed in a Restricted Access Area.

Installation Codes: The equipment must be installed according to country national electrical codes. For North America, equipment must be installed in accordance to the US National Electrical Code, Articles 110-16, 110-17 and 110-18, and the Canadian Electrical Code, Section 12.

Overcurrent Protection: A readily accessible Listed branch circuit overcurrent protective device, rated 15 A, must be incorporated in the building wiring.

CAUTION: This equipment is designed to permit connection between the earthed conductor of the DC supply circuit and the earthing conductor at the equipment.

Grounded Supply System: The equipment shall be connected to a properly grounded supply system. All equipment in the immediate vicinity shall be grounded the same way, and shall not be grounded elsewhere.

Local Supply System: The DC supply system is to be local, i.e. within the same premises as the equipment.

Disconnect Device: A disconnect device is not allowed in the grounded circuit between the DC supply source and the frame/grounded circuit connection.

Page 9: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-4

FibeAir 1500P Description FibeAir 1500P is Ceragon’s modular ultra high capacity network connectivity solution designed to meet growing market demands for increased spectral-efficient systems.

FibeAir 1500P is designed to deliver double the capacity using a single 28 MHz channel. In addition, the system is modular, easy to install, and a cost-effective alternative to fiber.

With FibeAir 1500P operating in co-channel dual polarization (CCDP) mode, using the cross polarization interference canceller (XPIC) algorithm, two STM-1 signals can be transmitted over a single 28 MHz channel, using vertical and horizontal polarization. This enables double capacity in the same spectrum bandwidth.

A cost-effective STM-1 ring configuration is achieved using a single FibeAir 1500P IDU located at each of the nodes, with one ODU providing the West connection and another providing the East connection.

For upgrading to a 311 Mbps ring, the built in CCDP mode can be activated to use the same single 28 MHz channel and equipment.

FibeAir 1500P can also be configured as an STM-1 1+1 hot standby terminal, in a 2U IDU shelf, with either a single or double antenna installation.

FibeAir 1500P is equipped with an internal SNMP agent for easy integration with standard network management systems, and can also be managed via CeraView, Ceragon’s network element manager, and PolyView, Ceragon’s network management platform. FibeAir 1500P also provides an internal Ethernet hub for in-band transmission of third party management information.

FibeAir 1500P can operate together with any industry standard ADM.

FibeAir 1500P IDU

Page 10: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-5

The following figure shows the FibeAir 1500P main modules and components.

As shown in the block diagram, the FibeAir 1500P IDU includes the following sections and functions:

Control Module The drawer on the left side of the IDU front panel. Includes the IDC (IDU Controller), wayside channel (optional), and replaceable fan unit.

The IDC handles the configuration and control of all system functions, including trail configurations, protection algorithms, network management tasks, performance monitoring, alarms detection/generation, and diagnostics.

Note that if a fan unit failure occurs, the entire IDC is replaced, a process that may take approximately 30 seconds.

Carrier Drawers The drawers to the right of the IDC Drawer. Include multiplexers, modem interfaces, line interfaces, and power supply units.

Note that in a 1+0 configuration the right drawer is used.

Multiplexer Receives data delivered via different communication protocols (such as DS-3, Ethernet, etc.) and converts it to a standard SDH framework for transmission through the air. On the receiving end, this module separates the SDH payload and overhead and reconstructs the original data that was converted.

Power Supply The ODU receives its DC power from the IDU. The PWR LED on the front panel of the IDU continuously lights to indicate the existence of input voltage. The DC input range is -40.5 VDC to -72 VDC.

Carrier Drawers A & B

IDC Drawer

BACKPLANE

Modem Board Channel A IF board Channel A

To IFchannel1

ODU

LED+interface moduleTerm

inal

SLIP

/PPP

Ethernet

Protection

Alarm

WS

C -

optionalFANS

ODU

IDC

Modem Board Channel B IF board Channel B

To IFchannel1

Power Supply

Power Supply

STM1/2 Daughter Board-48[V]

-48[V]

STM1/2 Daughter Board

Carrier A

Carrier B

IDC+WSC+Fans Module

5,3.3[v]

5,3.3[v]

XPIC modesynchronization

cable

Page 11: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-6

Modem Upon transmission, performs data conversion from the baseband frequency to the IF frequency. Upon receiving, performs data conversion from the IF frequency to the baseband frequency. It also performs AGC (Automatic Gain Control).

Line Interface Performs data framing and scrambling, and LOF detection.

Page 12: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-7

FibeAir IP-MAX Description FibeAir IP-MAX is Ceragon’s comprehensive Ethernet solution that offers Fast and Gigabit Ethernet wireless transmission with fiber-like quality. The IDU of the system is based on the 1500P IDU, and the components, except for the interfaces, are the same.

With the highest available throughput on the market, this Ethernet solution, with ultra-low latency, is optimized for IP based applications including IP-DSLAM connectivity for triple play services, WiMAX backhauling and any delay-sensitive application.

With upgradeable capacities of 50 to 400 Mbps per radio carrier, the IP-MAX carrier class solution provides a pay-as-you-grow, simple, and scaleable migration path for the ever-increasing demand for data-rich services.

Indoor Modules (IDMs)

FE IDM The Fast Ethernet IDM is a hot-swappable module inserted in the IP-MAX IDU. It provides configurable high-capacity Fast-Ethernet wireless transmission with Quality-of-Service (QOS) controls. Each Fast Ethernet IDM contains 2 x FE ports or 2 x FE with 8 x E1/DS1 ports and one radio interface.

Wire-speed FE IDMs are available with a single FE port (100 or 50 Mbps throughput) or 2 x FE ports with 200 Mbps full-duplex throughput. Capacity upgrades using software-licensed keys with specific serial numbers are available with 50 to 100 Mbps throughput and 100 to 200 Mbps throughput.

Physical Port Priority - If both Fast Ethernet ports are used, total Ethernet capacity is dynamically allocated between the two ports, or priority can be given to one port over the other.

Built-in Quality of Service - Provides priority support for different classes of service, according to VLAN priority (802.1p) and DiffServ / IPv4 TOS or IPv6 TC bit values. All classes use 4 levels of prioritization with user selectable options between strict priority queuing, or weighted fair queuing, with 8:4:2:1 strict weights.

Layer 2 Switch - Enables two separate LAN connections, while ensuring security between them.

GbE IDM The Gigabit Ethernet IDM is a hot-swappable module inserted in the IP-MAX IDU. It provides Gigabit wireless transmission, with each GbE IDM containing one GbE port, or GbE with 8 x E1/DS1 ports and one radio interface. GbE IDMs support traffic throughputs of up to 400 Mbps, full duplex, per single radio carrier.

Maximum Throughput - Supports 800 Mbps over a single 56 MHz channel, using co-channel and dual polarization (CCDP) with XPIC, in a single IDU (two IDMs with two carriers, and two different GbE physical interfaces).

Super Jumbo Frame Support - The Gigabit IDM supports frame sizes of up to 12,000 bytes. With this feature, IP-MAX is ready to support next generation Ethernet networks. In heavily loaded networks, where continuous data transfer is required, jumbo frames can significantly enhance the efficiency of Ethernet servers and networks. Jumbo frames enable the reduction of the packet processing by the server, thereby increasing end-to-end throughput.

Page 13: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-8

FibeAir IP-MAX2 Description FibeAir® IP-MAX2 is Ceragon’s comprehensive Gigabit Ethernet wireless transmission solution that delivers fiber-like quality.

FibeAir IP-MAX2 enables native Ethernet transmission with multiple frequencies, software selectable capacities, modulation schemes, and configurations for various network requirements, using the same hardware and state-of-the-art technology. The system supports high-capacity data services as well as traditional voice services, with both Ethernet and TDM interfaces.

This innovative platform uses an “on-the-fly” upgrade method, whereby network operators only buy capacity as needed, benefiting from savings on initial investments and OPEX.

The IP-MAX2 IDU (Indoor Unit) can host up to two carriers, each delivering up to 450 Mbps, optimizing the solution for different network topologies and configurations.

Traffic capacity throughput and spectral efficiency are optimized with the desired channel bandwidth. For maximum user choice flexibility, channel bandwidths can be selected together with a range of modulations, from QPSK to 256 QAM. Two independent hot swappable Indoor Unit Modules (IDMs) can be used for hot-standby hardware protection, diversity, East-West configuration, or double capacity (2+0).

High spectral efficiency is ensured by choosing the same bandwidth for double the capacity, via two carriers with vertical and horizontal polarizations. This feature is implemented by a built-in XPIC mechanism.

In short, IP-MAX2 is ideal for all your IP network-building needs.

Indoor Modules (IDMs) GBE IDMs come in two hardware types - optical and electrical.

Electrical GBE IDM Optical GBE IDM

Both IDMs are hot-swappable modules inserted in the IP-MAX2 IDU, providing wireless transmission with Quality-of-Service (QOS) controls. Each GBE IDM optionally allocates 8 x E1/T1 ports and one radio interface.

The electrical Gigabit Ethernet provides configurable high-capacity 10/100/1000BaseT while the optical GBE IDM has an SFP-based optics receptacle.

Capacity upgrades using software-licensed keys with specific serial numbers are available with 100, 200, 300, and 400 Mbps throughputs.

Page 14: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-9

Installing the IDU in a Rack

Warning! The intra-building port(s) of the equipment or subassembly is suitable for connection to intra-building or exposed wiring or cabling only. The intra-building port(s) of the eqiupment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4 port as described in GR-1089-CORE, Issue 4) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.

The FibeAir 1500P/IP-MAX/IP-MAX2 IDU is installed in a standard ETSI 19" rack as shown in the following illustration.

As shown in the illustration, four screws, supplied with the installation kit, are used to secure the IDU to the rack.

Page 15: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-10

IDU Dimensions

The following illustration shows the dimensions (in millimeters) of the FibeAir 1500P/IP-MAX/IP-MAX2 IDU.

Page 16: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-11

Grounding the IDU

The following illustration shows how the IDU is grounded to the rack.

A grounding wire is connected below the IDU-ODU interface using a single screw with two washers.

IDU Grounding Notes

• The IDU is suitable for installation in a Common Bonding Network (CBN).

• Only copper wire should be used.

• The wire must be at least 6 AWG.

• Connector and connection surfaces must be plated. Bare conductors must be be coated with antioxidant before crimp connections are made to the screws.

• FibeAir provides a ground for each drawer, via a one-hole mounted lug onto a single-point stud. The stud must be installed using a UL-listed ring tongue terminal, and two star washers for anti-rotation.

Single Point Stud

Page 17: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-12

• For antenna ports, lightning protection is used that does not permit transients of a greater magnitude than the following:

Open Circuit: 1.2-50us 600V

Short Circuit: 8-20us 300A

• The ampacity of the conductor connecting the IDU frame to the DC return conductor is equal to, or greater than, the ampacity of the associated DC return conductor.

Power Supply Notes

When selecting a power source, the following must be considered:

• DC power can be from -40.5 VDC to -72 VDC.

• Recommended: Availability of a UPS (Uninterrupted Power Source), battery backup, and emergency power generator.

• Whether or not the power source provides constant power (i.e., power is secured on weekends or is shut off frequently and consistently).

• The power supply must have grounding points on the AC and DC sides.

• The user power supply GND must be connected to the positive pole in the IDU power supply.

Power supply grounding should be in accordance with the following illustration:

Page 18: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-13

CAUTION!

It is extremely important not to short the -48 VDC (-) to GND. This will damage the IDU’s internal power supply module and terminate its operation.

Connecting the IDU

This section describes how the IDU interfaces are connected. The interfaces include line, system (IDU-ODU), and management ports.

For interface specifications, see Appendix A - Line Interfaces and Cables.

For connector pin-outs, see Appendix B - Connector Pin-Outs.

For a description of the protection kits, see Appendix C - Protection Kits.

Interface Descriptions

The following photo shows the different IDU ports and their functions.

As shown in the photo above, the IDC (Indoor Controller), in the left section of the FibeAir front panel, includes 2 Ethernet ports for management, Wayside channel connectors, terminal and SLIP connectors, an external alarms port, and a protection cable connector.

In addition, the front panel includes two drawers (IDMs) with internal modems, STM-1/OC-3 connectors, an N-Type IDU-ODU connector, and a DC power input connector. In a 1+0 configuration, the right drawer (IDM) is used.

Each modem drawer includes its own independent power supply unit and can be removed/replaced without causing other radio operation interference.

DC Power

N-Type Connector to ODU

DC Power

N-Type Connector to ODU

Interface Ports

Built-in Ethernet Hub (for management) 2 x Wayside Channels Terminal & SLIP User Channel External Alarms Protection

Interface Ports

Page 19: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 1-14

The Indoor Controller (IDC) provides advanced options, such as the Wayside channel, Engineering Order Wire, external alarm interfaces, external protection interface, auxiliary user channels, and Ethernet management interfaces. The controller is an extractable, hot swappable, and non-traffic-affecting drawer, with four different models to choose from.

All IDC models include management, external alarms, and protection interfaces. Only the type of auxiliary channel may vary in accordance with the specific system configuration.

The IDC can include the following:

TDM Wayside Channel - Two IDC models with either E1 or T1 wayside channel ports.

Ethernet Wayside Channel - 2 Mbps Ethernet channels (one per carrier). This IDC includes an Engineering Order Wire interface (G.711 CVSD) for point-to-point voice connectivity.

Ethernet Wayside Channel with Auxiliary User Channels - 2 Mbps Ethernet channels (one per carrier). In addition, two software-selectable user channels with the following options: 2 x RS-232 Asynchronous 9.6 Kbps, or 1 x RS-232 Asynchronous and 1 x V.11 Asynchronous (both 9.6 Kbps), or 1 x V.11 Synchronous co/contra-directional (64 Kbps). In asynchronous mode, each user channel can be associated with a different carrier. In synchronous mode, the single user channel can only be associated with the right side IDM carrier. This IDC also includes an Engineering Order Wire interface (G.711 CVSD) for point-to-point or concatenated voice connectivity.

IDU-ODU Coax Cable

The Coax Cable that connects between the IUD and the ODU should be terminated with N-type male connectors.

Important! Make sure that the inner pin of the connector does not exceed the edge of the connector.

The cable should have a maximum attenuation of 30 dB at 350 MHz.

Page 20: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-1

Chapter 2: Initial System Setup

General After the system is installed and tested, and antenna alignment is performed, the next step is initial IDU setup and configuration.

Initial setup procedures are performed on a craft terminal via a serial port connection.

Note:

Configuration procedures are generally performed using the CeraView® software supplied with FibeAir.

A description of CeraView and how to use it is provided in the CeraView User Guide.

The craft terminal should be used only to perform the initial setup procedures desribed in this chapter. Once the system is up and running, use CeraView to maintain and operate the system on a regular basis.

Initial Setup Steps

The initial FibeAir setup procedure includes the following steps:

Procedures Performed using a Craft Terminal:

- Connecting to the IDU via the terminal port

- Defining IP addresses

- Setup Options

Procedures Performed using CeraView:

- Connecting to the Ethernet port

- Installing the software

- Setting the local Tx frequency channel

- Specifying system information

- Configuring the local/remote transport

- Configuring trap forwarding

- Setting up external alarms

Connecting the Line Interfaces

Page 21: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-2

Initial Setup using the Craft Terminal The following procedures are performed after the RFU and antenna are installed.

Connecting to the IDU via Serial Port

Turn the IDU power switch ON.

On the front panel of the IDU, the DRWR LED should be lit green.

To set up the HyperTerminal connection:

1. Connect the RS-232 port of your computer to the RS-232 (9-pin) port on the IDU front panel. This port is labeled “Terminal”.

2. Select Start, Programs, Accessories, Communication, HyperTerminal.

3. Double-click the HyperTerminal application icon.

4. For Connection Description, type Terminal, and click OK.

5. In the Connect Using field (Phone Number), select Direct to Com 1, and click OK.

6. In the Port Settings tab (Com 1 Properties), specify the following settings:

Bits per second - 19,200 Data bits - 8 Parity - None Stop bits - 1 Flow control - Hardware

7. Click OK.

8. After you connect to the terminal, to enter the terminal setup program, press Enter.

9. For password, use ceragon.

Page 22: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-3

Defining IP Addresses

Before you can configure the FibeAir system, you need to define IP addresses using the craft terminal.

FibeAir includes two IP interfaces: an Ethernet interface, and a serial interface. Each interface has its own IP address and IP mask.

The IP address is a four digit number separated by decimal points. Each IP address is a pair netid,hostid, where netid identifies a network, and hostid identifies a host on the network. The IP mask separates between the netid and hostid.

For example, if the IP address is 192.114.35.12 (11000000 01110010 00100011 00001100), and the IP mask is 255.255.255.0 (11111111 11111111 11111111 00000000), the netid is 192.114.35, and the hostid is 12.

An IP interface can only communicate with hosts that are on the same net (have the same netid). In the example above, the interface can communicate only with hosts that have netid 192.114.35 (for 1 to 255).

If FibeAir has a frame to send to a host that is not on the Ethernet IP netid or the serial IP netid, the frame sould be sent to an intelligent device (usually a gateway) on the network. Such a device, known as a "default router", will know how to send the frame over the internet. The default gateway should be a host on one of the FibeAir interface netids.

The following figure shows how FibeAir is integrated in the local network.

Page 23: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-4

To define IP Addresses:

1. In the main terminal program menu, select Configuration.

2. Select IDC.

3. Select Basic.

4. Select IP and define the addresses as described above.

Important After you set up IP addresses, restart the IDU to activate them.

Setup Options in the Terminal Program

The main menu in the terminal setup program includes the following options:

Configuration (1) - the main setup section in which you can configure the IDC, the right and left drawers, protection, SNMP management, in-band routing, and other such parameters.

System Status (2) - used to obtain information about the different software versions currently used in the system.

Maintenance (3) - used to perform software upload, download, and reset.

Diagnostics (4) - used to perform loopbacks and obtain system information.

Logs (5) - used to view alarm and configuration log reports.

Page 24: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-5

Additional Setup Using CeraView Some of the initial setup procedures require the use of CeraView.

Once initial setup is complete, use CeraView to run the system on a daily basis.

Connecting to the Ethernet Port

1. Connect a crossed Ethernet cable from your PC to the Ethernet Port. If the connection is to a LAN (wall connection) use the standard Ethernet cable.

2. Make sure the IP address on your PC is on the same sub-net as you defined in the FibeAir indoor unit (in most cases, the first three numbers of the IP address must be identical, depending on the sub-net mask).

CeraView PC Requirements

Before you install the CeraView software, verify that your PC has the following minimum requirements:

For Windows

Processor: Pentium 4, 2.8 GHz (minimum)

Memory (RAM): 256 MB minimum

Operating System: Windows 2000 or above

Serial Port: RS-232 (Hyper-Terminal)

For UNIX

Processor: Blade 100 Ultra 5 (minimum)

Memory (RAM): 256 MB minimum

Operating System: Solaris 8 or 10

Installing the CeraView Management Software

Note: More detailed information about CeraView installation is provided in Chapter 5 - Operation.

1. Insert the CeraView CD in the CD drive.

2. In Windows Explorer, double-click the setup.exe file.

The installation program begins.

3. Follow the instructions displayed.

Page 25: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-6

Starting CeraView

1. Select Start, Programs, CeraView, CeraView Element Manager.

The CeraView Login window appears.

CeraView Login Window

2. Enter the IP address of the IDU, and the SNMP community (for SNMP protocol access).

3. For User Name use “admin” and for Password use “ceragon”.

4. Select Save Password if you want CeraView to remember the password you entered.

Note that there are two types of passwords, each with a different security level for authorized activities:Read Only - user is permitted to perform monitoring activities only.Read/Write - user is permitted to change system configuration and system administrator parameters, and perform monitoring activities.

After you log in, the Main CeraView window appears.

Main CeraView Window

Page 26: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-7

Setting the Local Tx Frequency Channel

If the Tx frequency was previously defined using the Hyperterminal, use this screen only to verify that the correct frequency was set.

1. Select Configuration, ODU Left/Right, ODU Configuration, or click the ODU icon in the tool bar.

At the top of the window, the system displays Tx/Rx ranges, the gap between them, and the channel bandwidth.

ODU Configuration Window

2. In the Frequency Control section, set the Tx Channel to the required channel. By default it is set to the first channel. If you are unsure of the required channel, refer to Appendix E for channel allocations. The frequency of the selected Tx channel appears in the Tx Frequency field.

3. If you prefer, you may set the Tx frequency by entering a frequency in MHz in the Tx Frequency section. If the frequency is not available, a warning message appears to enable the entered frequency or to change it to the next available channel.

4. Select the XPIC option (which appears under the ODU illustration) to activate the XPIC mechanism. The mechanism is used to cancel cross polar interference in a dual polarization system.

5. Select the Local Only option. By default, the Local + Remote option is selected. However, since there is no connection to the remote unit at this time, the Local + Remote option is not available.

Page 27: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-8

6. Click Apply to save the settings.

7. Click Close.

Specifying System Information

To specify system information:

1. Select File, Local/Remote, System Information., or click the System Information icon .

System Information Window

2. In the Current Time area, click Date/Time Configuration and set the date and time (in the format HH:MM:SS).

3. The read-only Description field provides information about the FibeAir system.

4. (Optional) In the Name field, enter a name for this link. By convention, this is the node’s fully-qualified domain name.

5. (Optional) In the Contact field, enter the name of the person to be contacted when a problem with the system occurs. Include information on how to contact the designated person.

6. (Optional) In the Location field, enter the actual physical location of the node or agent.

Page 28: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-9

7. The Up Time field, Software Versions area, and Serial Numbers area are read-only.

8. Click Apply. The settings are saved.

9. Click Close.

Local/Remote Transport Configuration

The Local/Remote Transport Configuration window allows you to change threshold levels for the radio and alarms, and to configure special transmission parameters. This is recommended for advanced users only.

Note: You will need to restart CeraView if you change the transport protocol.

1. Select Configuration, Local/Remote, IDU, Transport.

The Transport Configuration window appears.

Transport Configuration Window

2. The Protocol field displays the current data transfer protocol. To change the protocol, click the drop down list and select SDH, SONET, or SONET-C.

3. Click Apply to save the settings.

4. Click Close.

Trap Forwarding Configuration

This section explains how to set up a trap forwarding plan. If your application does not require trap forwarding, you can skip the following procedure.

1. Select Configuration, Local/Remote, Management System, Traps Configuration, or click the Traps Configuration icon.

The Trap Forwarding Configuration window appears.

Page 29: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-10

Trap Forwarding Configuration Window

2. In the Managers IP Address area, specify the IP addresses of the managers to which you want traps to be sent. For each manager IP you specify, specify the Trap Port, and for Send Trap for Alarms with Severity, select the severity filter to determine which types of alarms will be forwarded.

3. In the Send Trap for Alarms of Group section, you determine which alarms will be sent as SNMP traps to each manager. In each manager column, select the alarm types you want to include for that manager.

4. In the Trap Options area, select Standard traps include serial number if you want trap messages to include the IDU serial number.

Select Report local traps of far end IDU if you want remote IDU trap messages to be reported locally.

Select Use different ID for each alarm type if you want each type of alarm to receive a unique ID.

Select Send “clear” traps with zero severity if you want a trap with a “clear” severity (instead of the alarm's original severity) to be sent to the IP addresses you specified.

5. For CLLI (Common Language Location Identifier), enter up to 18 characters that will represent your system ID when traps are sent.

6. For Heartbeat Period, a heartbeat signal will be generated every x minutes (the number you enter) to tell your system that the trap meachnism is working.

Page 30: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-11

7. Click Apply to save the settings.

External Alarms Setup

The procedure detailed in this section is required only if alarms generated by external equipment are connected to the IDU, or if the IDU alarm outputs are connected to other equipment (using the alarms I/O connector).

1. Select Configuration, Local/Remote, IDU, External Alarms, or click the Local/Remote External Alarms icon.

The Input/Output External Alarms window appears.

Input/Output External Alarms Window

Follow the steps below for both the Local and Remote sides.

The microcontroller in the IDU reads alarm inputs (dry contact) and transmits them to the CeraView management system. This allows FibeAir to report external alarms that are not related to its own system.

For each alarm on the left side of the window, do the following:

2. Click on the box next to the alarm number to enable/disable the alarm.

3. If you enable an alarm, enter a description of the alarm in the text field.

4. Select the alarm’s severity level from the drop-down list (Major, Minor, Warning, or Event).

5. FibeAir provides three alarm outputs that can be used by other systems to sense FibeAir alarms. The outputs are configured on the right side of the window.

Page 31: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 2-12

The alarm outputs are Form C Relays. Each output relay provides three pins, as follows:

Normally Open (NO) Normally Closed (NC) Common (C)

Output alarms can be defined as any of the following:

Major Minor Warning External Power BER Line Loopback LOF IDU ODU Cable Remote

The default alarm output setting for each relay is “Power”.

The relays may be connected to customer-specific applications. Refer to Appendix B for details concerning the alarm connector pin assignments.

6. After you complete the configuration, click Apply to save the settings.

7. Click Close.

Exiting CeraView

To exit CeraView, select File, Exit in the main window.

Connecting Line Interfaces After configuring the system in accordance with the previous sections, the line interfaces can be connected to the IDU.

For a description of the line interfaces, see Appendix A in this guide.

Note the following interface terminology:

For connectors or signals labeled TX, the signals are sent from FibeAir.

For connectors or signals labeled RX, the signals are sent to FibeAir.

Page 32: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-1

Chapter 3: Acceptance & Commisssioning Procedures

General This chapter provides Ceragon's recommended Acceptance and Commissioning Procedure for FibeAir 1500P/IP-MAX/IP-MAX2. Acceptance and commissioning should be performed after initial setup is complete.

The purpose of this procedure is to verify correct installation and operation of the installed link and the interoperability with customer end equipment.

Ceragon's Acceptance and Commissioning procedure includes the following stages:

Site Acceptance Procedure

Commissioning of radio link in a 1+0 configuration

Commissioning of radio link in a 1+1 configuration

Commissioning of radio link in a 2+0 XPIC configuration

The Site Acceptance Procedure is a checklist that summarizes the installation requirements of the site at which the products were installed.

The commissioning tests cover the required configuration information that should be recorded, and the tests that should be performed on the radio link in 1+0, 1+1 and 2+0 XPIC configurations.

Page 33: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-2

Site Acceptance Procedure The purpose of the following procedures is to verify that all installation requirements were noted and checked. Following this procedure will ensure proper, long-lasting, and safe operation of the product.

The checklist below summarizes the installation requirements of the site.

SITE ACCEPTANCE CHECKLIST

1. SITE INFORMATION

Customer:

Radio model:

Site name:

Site code:

Radio link code:

Site address:

2. ANTENNA MOUNTING

Antenna mount type:

Mount is of sufficient height to clear local obstructions OK

Mount is safely positioned to not cause a safety hazard OK

Mount is secure and perpendicular OK

Mount is grounded as per site specifications OK

All steelwork is Galvanized or Stainless Steel as appropriate OK

3. ANTENNA

Antenna type (model and size):

Antenna is securely fixed to mount OK

Antenna is grounded as per site specifications OK

Antenna sway braces are installed correctly (where applicable) OK

Antenna Radome is securely fitted (where applicable) OK

Water drain plugs are fitted and removed, as appropriate OK

Antenna sealing O-Ring is properly fitted and not damaged OK

Antenna/Launch unit polarization is as per link requirements OK

Page 34: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-3

SITE ACCEPTANCE CHECKLIST

(continued)

4. OUT-DOOR UNIT

Type of ODU mount: (Direct or Remote mount)

ODU is securely mounted to the antenna or pole OK

ODU is grounded as per installation instructions OK

ODU‘s polarization is as per link requirements OK

ODU is installed properly and has no physical damage OK

For Remote-Mount Only:

Remote mount kit is securely mounted to the pole OK

Flexible waveguide has no physical damage and connectors are sealed OK

All flexible waveguide bolts are secured using washers and lock-washers, as appropriate OK

Flexible waveguide is secured to the pole OK

6. COAX CABLE

Overall cable length:

Cable type:

N-Type connectors assembled properly on the cable OK

Cable connected securely to ODU and IDU OK

Cable connector is weather-proofed (sealed) at the ODU OK

At the ODU, cable has a service/drip loop to prevent moisture from entering the connector OK

Cable is secured using suitable restraints to fixed points at regular intervals (0.5 m recommended) OK

Cable has no sharp bends, kinks, or crushed areas. All bends are per manufacturer specifications OK

Grounding/lightning protection is as per site specifications OK

Lightning protection type and model:

Cable point-of-entry to building/shelter is weather-proof OK

Cable ends are properly labeled OK

Page 35: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-4

SITE ACCEPTANCE CHECKLIST

(continued)

7. FLEXIBLE WAVEGUIDE

Overall flexible WG length:

Flexible WG type:

Flexible WG is connected securely to ODU and Antenna OK

Flexible WG connector is weather-proofed (sealed) at the ODU OK

At the ODU, the flexible WG has a service/drip loop to prevent moisture from entering the connector OK

Flexible WG is secured using suitable restraints to fixed points at regular intervals (0.5 m recommended) OK

Flexible WG has no sharp bends, kinks, or crushed areas. All bends are per manufacturer specifications OK

Flexible WG point-of-entry to building/shelter is weather-proof OK

Flexible WG ends are properly labeled OK

8. INDOOR UNIT

IDU is securely mounted to the rack OK

IDU is located in a properly ventilated environment OK

IDU fans are functional and air flow to the fans is not disrupted OK

IDU and rack are grounded as per site specifications OK

Traffic cables and connections are properly terminated as per manufacturer/cable instructions OK

All cabling is secured, tidy, and visibly labeled OK

9. DC POWER SUPPLY - Two Inputs

Measured DC voltage input to the IDU: (-40.5 to -72 VDC)

Power-Supply maximum current: (at least 3 Ampere)

Power-Supply is properly grounded OK

DC power backup type:

IDU DC connector is secure and the DC input leads are correctly terminated (no bare wires are visible) OK

IDU DC connector (+) and (GND) leads are shorted and GND is grounded OK

10. RACK INSTALLATION

Rack is mounted to the shelter floor with four screws OK

Rack is mounted to the shelter wall with two screws OK

Page 36: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-5

SITE ACCEPTANCE CHECKLIST (continued)

11. REMARKS/NOTES

12. GENERAL INFORMATION

Name:

Title:

Company:

Signature:

Site accepted by:

Date:

Name:

Title:

Company:

Signature:

Site approved by:

Date:

Site Acceptance Checklist Notes

The following notes provide important additional information about the Site Acceptance Checklist.

1. Antenna Mounting

Mounting pole is of sufficient height to clear local obstructions, such as parapets, window cleaning gantries, and lift housings.

Mounting Pole is of sufficient height, and is safely positioned, so as not to cause a safety hazard. No person should be able to walk in front of, or look directly into the path of the microwave radio beam. Where possible, the pole should be away from the edge of the building.

Mounting pole is secure and perpendicular. A pole that is not perpendicular may cause problems during antenna alignment.

Mounting pole is grounded as per site specifications. All operators and site owners have specific requirements regarding the grounding of installations. As a minimum, typical requirements are such that any metal structure must be connected to the existing lightning protection ground of the building. Where it extends beyond the 45 degree cone of protection of existing lightning conductors, additional lightning protectors should be installed.

All steelwork is Galvanized or Stainless Steel, as appropriate to prevent corrosion.

Page 37: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-6

2. Antenna

Antenna is grounded as per site specifications. See the third point in the Antenna Mounting section above.

Antenna sway braces are fitted and installed correctly, where applicable. Typically, for an antenna of 1.2 m or larger, an extra sway brace is fitted to the mounting frame of the antenna. This sway brace should not be mounted to the same pole as the antenna, but should be installed directly back to the tower or an alternative point.

Antenna Water Drain Plugs are fitted and removed, where appropriate. Some antennas have moisture drain plugs installed at various points around the antenna. The purpose of these plugs is to allow any moisture that forms on the inside of the antenna or radome to drip out and prevent a pool within the antenna. Only the plugs at the bottom of the antenna, after installation, should be removed. All other plugs should be left in position.

3. ODU (Outdoor Unit)

The ODU is grounded as per installation instructions. See the third point in the Antenna Mounting section above.

The ODU polarization is as per link requirements and matches the polarization of the antenna.

4. Indoor Unit

The main traffic connections are correctly terminated and crimped as per cable and connector manufacturer instructions. All fiber optic patch leads should be routed carefully and efficiently, using conduits to prevent damage to the cables.

All other user terminations are secure and correctly terminated.

All labeling is complete as per site requirements. Labeling is specific to each customer. At a site with only one installation, labeling may be unnecessary. However, at sites with multiple installations, correct and adequate labeling is essential for future maintenance operations.

Typical labeling requirements include:

Antenna labels - for link identity and bearing ODU labels - for link identity, frequency, and polarization Coax cable labels - for link identity, close to the ODU, IDU, and either end of any joint IDU labels - for link identity

Page 38: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-7

1+0 Commissioning Procedure

Scope This section describes the recommended commissioning tests for a FibeAir radio link in a 1+0 configuration.

The purpose of the commissioning tests is to verify correct and proper operation of the product.

Commissioning Test The following tests should be performed on each installed link.

Link Verification

“Radio” LED on the IDM front panel is green, indicating the radio link is up.

Received Signal Level (RSL) is up to +/- 4 dB from the expected (calculated) level at both ends of the link.

Radio Bit Error Rate (BER) is 10E-11 or higher.

If working with ATPC, ATPC is operating as expected (RSL = reference level).

After connecting test equipment or end equipment to the line interfaces, all LEDs on the front panel of the IDM are green.

Line Interfaces Test

155 Mbps Interface - connect SDH/SONET/ATM test equipment to the 155 Mbps interface and verify error-free operation for at least 1 hour. Use a physical or software loop at the far end.

50/100/200 Mbps, GbE Interface - connect a Packet Analyzer to the Fast Ethernet interface and verify error-free operation (no packet loss) for at least 1 hour. Use a physical loop at the far end.

45 Mbps Interface - connect PDH test equipment to the DS3 interface and verify error-free operation for at least 1 hour. Use a physical or software loop at the far end.

2 Mbps/1.5 Mbps - connect PDH test equipment to the E1/T1 interface and verify error-free operation for at least 1 hour. Use a physical or software loop at the far end.

Interoperability Verification

Connect customer end equipment to the line interfaces, and verify correct operation.

Further interoperability tests should be performed in accordance with the specific requirements of the connected end equipment.

Page 39: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-8

Management Verification

Install CeraView element manager software on the PC, and launch the program.

Verify that you can manage the link and that you are able to perform changes to the link configuration (frequency channel, Tx power, system name, time & date, etc.) via CeraView.

Verify that CeraView reports the correct parameters when performing the above.

Verify that there are no active alarms on the link.

If the management station is located at a remote site (Network Operation Center), verify that the management station can manage the link and receive traps.

Loopback Operation

Perform line loopback, IDU loopback, ODU loopback, and Remote loopback, and verify that the system operates accordingly.

Page 40: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-9

1+1 Commissioning Procedure

Scope This section describes the recommended commissioning tests for a FibeAir radio link in 1+1 HSB (Hot Standby) and SD (Space Diversity) or FD (Frequency Diversity) configurations (internal protection).

The purpose of the commissioning tests is to verify correct and proper operation of the product.

Note that in this section:

Primary refers to the the ODUs connected to the main path of the directional coupler in a 1+1 HSB configuration.

Secondary refers to the ODUs connected to the secondary path of the directional coupler in a 1+1 HSB configuration.

Commissioning Tests

The following tests should be performed on each installed link.

Link Verification

The following steps should be repeated for each of the four ODU combinations (Primary-Primary, Primary-Secondary, Secondary-Primary, Secondary-Secondary).

“Radio” LED on the IDM front panel is green, indicating the radio link is up.

Received Signal Level (RSL) is up to +/- 4 dB from the expected (calculated) level at both ends of the link.

Radio Bit Error Rate (BER) is 10E-11 or higher.

If working with ATPC, ATPC is operating as expected (RSL = reference level).

After connecting test equipment or end equipment to the line interfaces, all LEDs on the front panel of the IDM are green.

Line Interfaces Test

155 Mbps interface - connect SDH/SONET/ATM test equipment to the 155 Mbps interfaces using splitters, and verify error-free operation for at least 1 hour. Use physical loop between the splitters at the far end.

50/100/200 Mbps, GbE interface - connect a Packet Analyzer to the Fast Ethernet interfaces using an FE splitter, and verify error-free operation (no packet loss) for at least 1 hour. Use a physical loop at the far end.

45 Mbps interface - connect PDH test equipment to the DS3 interfaces using splitters, and verify error-free operation for at least 1 hour. Use a physical loop between the splitters at the far end.

2 Mbps/1.5 Mbps - connect PDH test equipment to the E1/T1 interfaces using splitters, and verify error-free operation for at least 1 hour. Use a physical loop between the splitters at the far end.

Page 41: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-10

Switching Tests

Define each of the N channels as preferred (one at a time) for errorless switching to the +1 channel. The regular channel supports hitless switching to the +1 channel.

155 Mbps Interface

Connect SDH/SONET/ATM test equipment to the 155 Mbps interfaces using splitters. Use physical loop between the splitters at the far end. Verify that there are no alarms.

Perform the following switching tests from one IDM to the other, and verify the system switches automatically.

- Power: power off the active IDM

- Radio: disconnect the coax cable of the active IDM

- Line: disconnect the 155 Mbps line input of the active IDM

- Management: force a switch using CeraView

For diversity configurations, verify that each receiver is receiving its own signal, and then mute the active ODU. Verify that the receiver at the far end still receives from the diversity path. Verify that there are no errors in the test equipment.

50/100/200 Mbps, GbE Interface

Connect a Packet Analyzer to the Fast Ethernet interfaces using splitters. Use a physical loop between the splitters at the far end. Verify no alarms exist.

Perform the following switching tests from one IDM to the other, and verify the system switches automatically.

- Power: power off the active IDM

- Radio: disconnect the coax cable of the active IDM

- Management: force a switch using CeraView

45/2/1.5 Mbps Interface

Connect PDH test equipment to the interfaces using splitters. Use a physical loop between the splitters at the far end. Verify no alarms exist.

Perform the following switching tests from one IDM to the other, and verify the system switches automatically.

- Power: power off the active IDM

- Radio: disconnect the coax cable of the active IDM

- Management: force a switch using CeraView

Interoperability Verification

Connect the customer end equipment to the line interfaces and verify correct operation.

Further interoperability tests should be performed in accordance with the specific requirements of the connected end equipment.

Page 42: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-11

Management Verification

Install CeraView element manager software on the PC and launch the program.

Verify that you can manage the link and that you are able to perform changes to the link configuration (frequency channel, Tx power, system name, time & date, etc.) via CeraView.

Verify that CeraView reports the correct parameters when performing the above.

Verify that there are no active alarms on the link.

If the management station is located a t a remote site (Network Operation Center), verify that the management station can manage the link and receive traps.

Page 43: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-12

2+0 XPIC Commissioning Procedure

Scope

This section describes the recommended commissioning tests for a FibeAir radio link in a 2+0 XPIC Co-Channel-Dual-Polarization configuration.

The purpose of the commissioning tests is to verify correct and proper operation of the product.

Important! Since operation of the XPIC system depends on correct installation, make sure the guidelines for XPIC system installation provided below are followed correctly.

XPIC Installation Guidelines

Antenna and ODU Installation

1. Install the dual polarization antenna and point it in the direction of the other site.

2. Install the two ODUs on a dual polarization antenna using the appropriate mounting kit, and mark the ODUs with V and H respectively.

IDU-ODU Cable Installation

1. Install two cables between the ODUs and the drawers (IDMs). Note that cable length difference should not exceed 10 meters.

2. Mark the cables with V and H respectively, and make sure V is connected to the right drawer and H is connected to the left drawer.

3. Mark the drawers respectively.

Antenna Alignment

1. Power up drawer V on both ends of the link and configure it to the desired frequency channel and maximum power.

2. Align the antennas, one at a time, until expected RSL is achieved. Make sure the achieved RSL is no more than +/-4 dB from the expected level.

Polarization Alignment

Polarization alignment is required to verify that the antenna feeds are adjusted, to ensure that the antenna XPD (Cross Polarization Discrimination) is achieved.

Polarization adjustment should be done on one antenna only.

1. Power up drawer V on both ends of the link and record the RSL reading on one end.

2. Power off drawer V on that end and power on drawer H.

Page 44: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-13

3. Check the RSL obtained on this ODU on H pol, and compare it to the RSL obtained by the ODU installed on the V pol.

4. Verify that XPI (Cross Polarization Interference) is at least 25 dB

where:

sites.both at used onspolarizati orthogonal with RSLLink RSLsites.both at usedon polarizati same with theRSLLink RSL

XPOL

POL

→→

−= XPOLPOL RSLRSLXPI

5. If XPI is less than 25 dB, adjust the feed polarization by opening the polarization screw and gently rotating the feed to minimize the RSLXPOL.

Note that polarization alignment is not always possible since the RSLXPOL may fall below the sensitivity threshold of the ODU.

It is also recommended to try to maximize the XPI as much as possible, by aligning the polarization.

XPIC Commissioning Tests

Individual Link Verification

Before operating in XPIC configuration, each of the links (V and H) should be commissioned individually in order to verify its proper operation.

1 Power up only drawer V at both ends and verify its frequency channel and Tx power configuration.

2 Verify that the RSL is no more than +/-4 dB from the expected level.

3 Run BER stability test on the link for at least 15 minutes to ensure error-free operation.

4 Power up only drawer H at both ends and verify its frequency channel and Tx power configuration.

5 Verify that the RSL is no more than +/-4 dB from the expected level.

6 Run BER stability test on the link for at least 15 minutes to ensure error-free operation.

XPIC Configuration Verification

1 Using the XPIC cable, connect the two ODUs at each end to the TNC connectors. Make sure the cable is no longer than 3 meters.

2 Configure the drawers to work in XPIC mode.

3 Verify that the RSL at all four ODUs is no more than +/-4 dB from the expected level.

4 Verify that no alarms exist (if a 155 Mbps line is connected).

5 Run BER stability test on each of the 155 Mbps links for at least 1 hour to ensure error-free operation.

Note: In a 2+2 configuration, repeat each step above for each of the four coupled ODU combinations.

Page 45: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-14

XPIC Recovery Verification

In order to verify XPIC operation, simulate the faults described below.

1 Disconnect the IDU-ODU cable for each of the drawers (one at a time), and verify that the other link is operating.

2 Disconnect the XPIC cable and check that the relevant alarms are generated.

3 Power down each of the drawers and verify that the other link is operating.

4 Swap the V and H cables and check that the relevant alarm is generated.

5 Mute and then un-mute one ODU at a time and verify that the other link is operating.

Note: In a 2+2 configuration, repeat each step above for each of the four coupled ODUs connected to the two standby IDUs.

2+2 Verification

Perform the tests specified in Switching Tests in the 1+1 Commissioning Procedure section earlier in this guide.

In this case, the switch will be from a main IDU connected to the main V and main H ODUs, to the secondary IDU connected to the coupled V and coupled H ODUs.

Page 46: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-15

FibeAir 1500P/IP-MAX/IP-MAX2 Commissioning Log The Commissioning Log is an integral part of the commissioning procedure and should be filled in for each installed link.

The Commissioning Log gathers all relevant information regarding the installed link and contains a checklist of all recommended commissioning tests.

Maintaining the Commissioning Log is important for tracking your installations, and to provide essential data for Ceragon Networks.

Upon completing the Commissioning Log, send the log to Ceragon support center at [email protected].

FIBEAIR 1500P/IP-MAX/IP-MAX2 LINK COMMISSIONING LOG

1. GENERAL INFORMATION

Customer:

Radio model:

Configuration:

Radio link code:

Site 1 name & add:

Site 2 name & add:

2. INDOOR UNIT Site 1 Drawers

Right / Left Site 2 Drawers

Rigt / Left

IDC model:

Wayside channel:

IDC p/n:

IDC s/n:

SW IDC:

Drawer model

Main channel

Drawer p/n

Drawer s/n

FW Mux:

FW Modem:

Cfg Modem:

Page 47: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-16

FIBEAIR 1500P/IP-MAX/IP-MAX2 LINK COMMISSIONING LOG

(continued)

3. ODU Site 1 Drawers

Right / Left Site 2 Drawers

Right / Left

ODU model:

ODU p/n:

ODU Main s/n:

SW ODU:

Tx frequency (MHz):

Rx frequency (MHz):

Link ID:

Tx power (dBm):

ATPC on/off:

ATPC ref level:

ODU Polarization:

4. ANTENNA Site 1 Drawers Right / Left

Site 2 Drawers Right / Left

Antenna model:

Antenna size:

Manufacturer:

Mounting type:

Mounting losses:

5. LINK PARAMETERS Site 1 Drawers

Right / Left Site 2 Drawers

Right / Left

Link distance:

Rain zone:

Expected RSL (dBm):

Expected Diversity RSL (dBm):

RSL Main (dBm):

RSL Diversity (dBm):

Deviation from exp?

RSL ≤4 dB?

Page 48: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-17

FIBEAIR 1500P/IP-MAX/IP-MAX2 LINK COMMISSIONING LOG

(continued)

6. COMMISSIONING TESTS Site 1 Drawers

Right / Left Site 2 Drawers

Right / Left

Front panel LEDs: All green All green All green All green

Line loopback: Pass Pass Pass Pass

IDU loopback: Pass Pass Pass Pass

ODU loopback: Pass Pass Pass Pass

Radio BER: Pass Pass Pass Pass

STM-1 test: Pass Pass Pass Pass

Fast Ethernet test: Pass Pass Pass Pass

8 x E1/T1 test: Pass Pass Pass Pass

E3/DS3 test: Pass Pass Pass Pass

Wayside E1 test: Pass Pass Pass Pass

Wayside Eth test: Pass Pass Pass Pass

XPIC test: Pass Pass Pass Pass

Switching test: Pass Pass Pass Pass

7. MANAGEMENT CONFIGURATION Site 1 Site 2

Eth Main IP address:

Eth Coupled IP address:

Eth IP mask:

Serial IP address:

Serial IP mask:

Default router:

In-band enabled?

Gateway/NE:

In-band channel 1:

In-band channel 2:

Ring IP address:

Ring IP mask:

Network ID:

8. REMARKS/NOTES

Page 49: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide 3-18

FIBEAIR 1500P/IP-MAX/IP-MAX2 LINK COMMISSIONING LOG

(continued)

9. INSTALLATION INFORMATION

Name:

Company:

Date: Installed by:

Signature:

Name:

Company:

Date: Commissioned by:

Signature:

Page 50: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide A-1

Appendix A: Line Interfaces and Cables This section provides a description of the FibeAir main channel, wayside channel, and order wire channel interfaces.

The interfaces are located on the FibeAir IDU front panel.

The following interface terms should be noted:

For connectors or signals labeled TX, the signals are sent from FibeAir.

For connectors or signals labeled RX, the signals are sent to FibeAir.

Main Channel Interfaces

Main channel interfaces include the following:

SC/MM/13

Multi Mode 155 Mbps, SC Optical Connector

Wavelength: 850 nm

Connector: SC

Used with: Multi mode fiber

Protocols supported: STS-3c, STM-1, OC-3, STS-1, FDDI, TAXI, Fast Ethernet

Timing mode: Retimed

Coding method: 4B/5B, NRZ

Optical output to 62.5/125 fiber: -18 dBm

Receiver sensitivity: -31 dBm

Maximum input power: -14 dBm

Page 51: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide A-2

SC/SM/13

Single Mode 155 Mbps, SC Optical Connector

Wavelength: 1300 nm

Connector: SC

Used with: Single mode fiber

Protocols supported: STS-3c, STM-1, OC-3, STS-1, FDDI, TAXI, Fast Ethernet

Timing mode: Retimed

Coding method: 4B/5B, NRZ

Maximum output to 9/125 fiber: -8 dBm

Receiver sensitivity: -31 dBm

Maximum input power: -8 dBm

CMI

Electrical 155 Mbps Connector

Connector: CMI 1.0/2.3

Used with: Coax cable

Protocols supported: STS-3c, STM-1, OC-3

Line coding: CMI

Timing mode: Retimed

Range calculation: 12.7 dB at 78 MHz according to square root of frequency law 150 m is attainable using RG-59 B/U cables (cable length varies in accordance

with type)

Impedance: 75 Ω

DS-3

Connector: CMI 1.0/2.3

Used with: Coax cable

Protocols supported: DS-3

Line coding: B3ZS

Timing mode: Retimed

Range calculation: 12.7 dB at 78 MHz according to square root of frequency law

150 m is attainable using RG-59 B/U cables (cable length varies in accordance with type)

Impedance: 75 Ω

Page 52: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide A-3

8xE1/T1

Connector: SCSI-36

Used with: Twisted Pair

Protocols supported: E1/T1

Timing mode: Retimed

Range: 100 m

Impedance: 120 Ω/100 Ω

Receive Cable

Twisted Pairs RX Signals SCSI-36 Pin #

R-RING0 19 Twisted Pair

R-TIP0 1

R-RING1 20 Twisted Pair

R-TIP1 2

R-RING2 21 Twisted Pair

R-TIP2 3

R-RING3 22 Twisted Pair

R-TIP3 4

R-RING4 23 Twisted Pair

R-TIP4 5

R-RING5 24 Twisted Pair

R-TIP5 6

R-RING6 25 Twisted Pair

R-TIP6 7

R-RING7 26 Twisted Pair

R-TIP7 8

Shield CGND (1) 9

Transmit Cable

Twisted Pairs RX Signals SCSI-36 Pin #

T-RING0 29 Twisted Pair

T-TIP0 11

T-RING1 30 Twisted Pair

T-TIP1 12

T-RING2 31 Twisted Pair

T-TIP2 13

T-RING3 32 Twisted Pair

T-TIP3 14

T-RING4 33 Twisted Pair

T-TIP4 15

Page 53: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide A-4

Transmit Cable (contd)

Twisted Pairs RX Signals SCSI-36 Pin #

T-RING5 34 Twisted Pair

T-TIP5 16

T-RING6 35 Twisted Pair

T-TIP6 17

T-RING7 36 Twisted Pair

T-TIP7 18

Shield CGND 10

100Base-T (Fast Ethernet, Electrical)

Connector: Shielded RJ-45

Used with: UTP Cat 5

Protocols supported: Fast Ethernet (100Base-T), full/half duplex

Timing mode: Retimed

Range: 100 m

Impedance: 100 Ω

100Base-T LED Indicators

LED Color Indication

LINK Constant Green Normal operation

ACT Blinking Green LAN receiving/transmitting data

100Base-T Connector Pin-Out

Pin Function

Pin 1 CH1_Tx+

Pin 2 CH1_Tx

Pin 3 CH1_Rx+

Pin 4 CH2_Tx+

Pin 5 CH2_Tx

Pin 6 CH1_Rx

Pin 7 CH2_Rx+

Pin 8 CH2_Rx

Page 54: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide A-5

Gigabit Ethernet (Optical)

1000Base-SX (Short Haul Fiber)

Wavelength: 850 nm

Receptacle: MSA compliant, SFP (Small Form Factor Pluggable Ports)

Connector: LC

Max Segment Length: 220 m (1351 ft), 500 m (1650 ft)

Cable Type: For Max Segment = 220 m: 62.5 µm MMF

For Max Segment = 500 m: 50 µm MMF

1000Base-LX (Long Haul Fiber)

Wavelength: 1350 nm

Receptacle: MSA compliant, SFP (Small Form Factor Pluggable Ports)

Connector: LC

Max Segment Length: 550 m (1805 ft), 5000 m (16404 ft)

Cable Type: For Max Segment = 550 m: 62.5 µm MMF, 50 µm MMF

For Max Segment = 5000 m: 10 µm SMF

Gigabit Ethernet (Electrical)

1000BaseT (Twisted Pair Cable)

Receptacle: MSA compliant SFP (Small Form Factor Pluggable Ports)

Connector: RJ-45

Max Segment Length: Up to 100 m (328 ft) per IEEE802.3

Cable Type: Compatible with shielded and unshielded twisted pair category 5 cables.

Page 55: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide A-6

Wayside Channel Interfaces

The Wayside channel is used as an auxiliary audio or data channel.

FibeAir supports the following wayside interfaces:

10BaseT (Ethernet)

Connector: Shielded RJ-45

Used with: UTP Cat 5

Protocols supported: Ethernet (100/10Base-T), half or full duplex

Timing mode: Retimed

Range: 100 m

Impedance: 100 Ω

100/10Base-T LED Indications

LED Color Indication

LINK RX/TX Green Normal operation with wayside enabled

LINK Down Red LOS - Loss of Signal

Disabled Grey (LED off) Wayside channel is disabled

100/10Base-T Connector Pin-Out

Pin Function

Pin 1 CH1_Tx+

Pin 2 CH1_Tx

Pin 3 CH1_Rx+

Pin 4 CH2_Tx+

Pin 5 CH2_Tx

Pin 6 CH1_Rx

Pin 7 CH2_Rx+

Pin 8 CH2_Rx

Page 56: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide A-7

E1/G.703

Connector: Shielded RJ-45

Used with: UTP Cat 5

Protocols supported: E1

Timing mode: Retimed

Range: 100 m

Impedance: 120 Ω

E1 LED Indications

LED Color Indication

LINK RX/TX Green Normal operation with waysdie enabled

LINK Down Red LOS - Loss of Signal

Disabled Grey (LED off) Wayside channel is disabled

G.703/E1 Connector Pinout

Pin Function

Pin 1 CH1_Rx+

Pin 2 CH1_Rx-

Pin 3 CH2_Rx+

Pin 4 CH1_Tx+

Pin 5 CH1_Tx-

Pin 6 CH2_Rx+

Pin 7 CH2_Tx+

Pin 8 CH2_Tx-

Page 57: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide A-8

T1 Connector: RJ-45

Used with: UTP Cat 5

Impedance Type: Balanced

Impedance: 100 Ω

T1 LED Indications

LED Color Indication

LINK RX/TX Green Normal operation with wayside enabled

LINK Down Red LOS - Loss of Signal

Disabled Grey (LED off) Wayside channel is disabled

T1 Connector Pinout

Pin Function

Pin 1 CH1_Rx+

Pin 2 CH1_Rx-

Pin 3 CH2_Rx+

Pin 4 CH1_Tx+

Pin 5 CH1_Tx-

Pin 6 CH2_Rx+

Pin 7 CH2_Tx+

Pin 8 CH2_Tx-

Page 58: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide A-9

Order Wire Channel Interface

The Order Wire is used for audio transmission for testing or maintenance purposes.

The specifications for this channel are as follows:

Termination Type: Headset stereo plug, 2.5 mm

Frequency band (KHz) 0.3-3.4

Input impedance (ohms) 2000

Output impedance (ohms) 32

Input signal level (dBm) 0 to -27

Output signal level (dBm) 38

Signal level vs frequency (dB) In accordance with ITU-T G.712

Input/output backside signal attenuation (dB) out of frequency band:

For 300-600 KHz, no less than 16

For 600-3400 KHz, no less than 20

Analog input gain (dB) 14

Analog output gain (dB) 0

Page 59: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide B-1

Appendix B: Connector Pin-Outs

General

This appendix provides pin-outs for FibeAir IDU connectors, including the following:

External Alarms Connector

Protection Connector

8 x E1/T1 Connector

Modem-PPP Cross Cable

Wayside Channel Connectors

User Channel

Page 60: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide B-2

External Alarms Connector Pin-Out The External Alarms connector is a D-type 15 pin connector.

Pin Signal I/O Description

1 EXT_IN_1 Input External input alarm #1

2 EXT_IN_2 Input External input alarm # 2

3 EXT_IN_3 Input External input alarm #3

4 EXT_IN_4 Input External input alarm #4

5 EXT_IN_5 Input External input alarm #5

6 Relay 3 C Output Relay #3 common pin

7 Relay 3 NO Output Relay #3 normally open pin

8 Relay 2 NO Output Relay #2 normally open pin

9 GND GND GND

10 Relay 1 NC Output Relay #1 normally closed pin

11 Relay 3 NC Output Relay #3 normally closed pin

12 Relay 2 C Output Relay #2 common pin

13 Relay 2 NC Output Relay #2 normally closed pin

14 Relay 1 C Output Relay #1 common pin

15 Relay 1 NO Output Relay #1 normally open pin

Page 61: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide B-3

Protection Connector Pin-Out The Protection connector for is an Rj-45, 8-pin, male type connector.

Pin

Left Right Function

1 1 GND

2 5 E_SLF_OUT

3 6 IDC TXD

4 7 Cable Echo

5 2 E_MT_IN

6 3 IDC RXD

7 4 NA

8 8 GND

8 x E1/T1 Connector Pin-Out The 8 x E1/T1 connector is a 36-pin connector.

Connector Pin #

Signals Color ConnectorPin #

Signals Color

11 OUT - TIP 1 Brown/Red 1 IN - TIP 1 Blue/White

29 OUT - RING 1 Red/Brown

TWISTED PAIR

19 IN - RING 1 White/Blue

TWISTED PAIR

12 OUT - TIP 2 DarkBlue/Red 2 IN - TIP 2 Orange/White

30 OUT - RING 2 Red/DarkBlue

TWISTED PAIR

20 IN - RING 2 White/Orange

TWISTED PAIR

13 OUT - TIP 3 Blue/Black 3 IN - TIP 3 Green/White

31 OUT - RING 3 Black/Blue

TWISTED PAIR

21 IN - RING 3 White/Green

TWISTED PAIR

14 OUT - TIP 4 Orange/Black 4 IN - TIP 4 Brown/White

32 OUT - RING 4 Black/Orange

TWISTED PAIR

22 IN - RING 4 White/Brown

TWISTED PAIR

15 OUT - TIP 5 Green/Black 5 IN - TIP 5 DarkBlue/White

33 OUT - RING 5 Black/Green

TWISTED PAIR

23 IN - RING 5 White/DarkBlue

TWISTED PAIR

16 OUT - TIP 6 Brown/Black 6 IN - TIP 6 Blue/Red

34 OUT - RING 6 Black/Brown

TWISTED PAIR

24 IN - RING 6 Red/Blue

TWISTED PAIR

17 OUT - TIP 7 DarkBlue/Black 7 IN - TIP 7 Orange/Red

35 OUT - RING 7 Black/DarkBlue

TWISTED PAIR

25 IN - RING 7 Red/Orange

TWISTED PAIR

18 OUT - TIP 8 Blue/Yellow 8 IN - TIP 8 Green/Red

36 OUT - RING 8 Yellow/Blue

TWISTED PAIR

26 IN - RING 8 Red/Green

TWISTED PAIR

9,10 Shell (1) - SHIELD

Page 62: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide B-4

Notes:

• Shell is connected to IDU chassis GND.

• The following pins are not connected: 27,28.

Modem-PPP Cross Cable Pin-Outs

This section provides pin-outs for the cross cable installed between the dial-up modem and the FibeAir PPP interface.

DB9 to DB9 Cross Cable

DB9 Male Connection DB9 Male

TX 2 2 RX

RX 3 3 TX

DTR 4 1 DCD

CTS 8 7 RTS

RTS 7 8 CTS

DCD 1 4 DTR

GND 5 5 GND

DB9 to DB25 Cross Cable

DB9 DB25

1 20

2 2

3 3

4 8

5 7

7 5

8 4

Notes:

1. Shell is connected to IDU chassis GND.

2. The following pins are not connected: 6, 7, 8, 9, 15, 23, 36, 37, 38, 39.

Page 63: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide B-5

Wayside Channel Connector Pin-Outs

The following are pin-outs for Wayside channel interfaces.

E1/T1 Connector Pin-Out

RJ-45 Male Connector

Pin Signal

1 Ch1_Rx+, Receive Positive - Primary

2 Ch1_Rx-, Receive Negative - Primary

3 Ch2_Rx+, Receive Positive - Secondary

4 Ch1_Tx+, Transmit Positive- Primary

5 Ch1_Tx-, Transmit Negative - Primary

6 Ch2_Rx-, Receive Negative - Secondary

7 Ch2_Tx+, Transmit Positive - Secondary

8 Ch2_Tx-, Transmit Negative - Secondary

10BaseT Connector Pin-Out

RJ-45 Male Connector

Pin Signal

1

2 Twisted Pair, Out - Tx Ch2 (Right)

3

6 Twisted Pair, In - Rx Ch2 (Right)

4

5 Twisted Pair, Out - Ch1 Tx (Left)

7

8 Twisted Pair, In - Ch1 Rx (Left)

Page 64: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide B-6

User Channel Connector Pin-Out

The following table lists the pins for the user channel interface.

The user channel connector is D-type 9-pin connector.

Pin Serial PPP Asynchronous UC - RS-232

Asynchronous UC - V.11

Synchronous UC - V.11 I/O

1 DCD

Data Carrier Detected

(N.C) UC1_TxD - UC_TxCLK - Transmitted

Clock Out

2 RxD Received Data

UC1_TxD Transmitted

Data UC1_TxD +

UC_TxCLK+ Transmitted

Clock Out

3 TxD Transmitted Data

UC1_RxD Received Data UC1_RxD + UC_RxCLK+

Received Clock In/Out

*

4 DTR

Data Terminal Ready

(N.C) UC1_RxD - UC_RxCLK- Received Clock

In/Out *

5 SG Signal Ground

SG Signal Ground

SG Signal Ground

SG Signal Ground Com

6 DSR Data Set Ready (N.C) UC2_TxD - UC_TxD - Out

7 RTS Request To Send

UC2_RxD Received Data UC2_RxD + UC_RxD + In

8 CTS Clear To Send

UC2_TxD Transmitted

Data UC2_TxD + UC_TxD + Out

9 RI

Ring Indicator (N.C)

(N.C) UC2_RxD - UC_RxD - In

* Output in case of contra-directional mode

Page 65: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide C-1

Appendix C: Protection Kits

STM-1/OC-3 SM/SC Protection Kit (PRT-SM/SC)

This kit is used for protected configurations with STM1/OC3 optical SM (Single Mode) interfaces.

Two optical splitters (SM/SC OPTICAL SPLITTER, CONN. 1300 nm 50/50 1M, AO-0007-0) are included in the kit (one for Rx and the other for Tx).

STM-1/OC-3 MM/SC Protection Kit (PRT-P-STM1-MM/SC)

This kit is used for protected configurations with STM-1/OC-3 optical MM (Multi Mode) interfaces.

Two optical splitters (MM/SC/PC OPTICAL, SPLITTER 62.5/125 L=0.5 m, WP-0003-0) are included in the kit (one for Rx and the other for Tx).

The splitter is the same as the one shown above for single mode, except for its color, which is orange.

Page 66: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide C-2

STM-1/OC-3 Electrical Protection Kit (PRT-P-STM1-ELC_10/23) This kit is used for protected configurations with STM-1 electrical interfaces.

Four coax cables (COAX.1.0/2.3 TO BNC STR. PLUG CABLE, 25 cm, 75 Ohm, WA-0175-0), and two electrical splitters (ELECTRICAL SPLITTER POWER 75 OHM 2:1 5-600 MHz, AO-0002-0) are included in the kit.

Splitter with two cables:

Assembled kit:

Page 67: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide C-3

DS3 Internal Protection Kit (PRT-P-DS3) This kit is used for protected configurations with DS3 electrical interfaces.

Four coax cables (COAX.1.0/2.3 TO BNC STR. PLUG CABLE, 25 cm, 75 Ohm, WA-0175-0), and two electrical splitters (ELECTRICAL SPLITTER POWER 75 OHM 2:1 5-600 MHz, AO-0002-0) are included in the kit.

3xDS3 Internal Protection Kit (PRT-P-3DS3) This kit is used for protected configurations with 3xDS3 electrical interfaces.

Twelve coax cables (COAX.1.0/2.3 TO BNC STR. PLUG CABLE, 25 cm, 75 Ohm, WA-0175-0), and six electrical splitters (ELECTRICAL SPLITTER POWER 75 OHM 2:1 5-600 MHz, AO-0002-0) are included in the kit.

2xFast Ethernet Protection Kit (PRT-P-2ETH) This kit is used for protected configurations with 2xFE interfaces.

Each RJ-45 connector includes two FE ports.

One Ethernet WSCH split cable (WA-0140-0) is used, which splits two FE inputs in one RJ-45 connector, to two separate inputs.

One RJ-45 spliced twisted pair cable for Ethernet (WA-0188-0) is shown below. The "Y" splitter connects two RJ-45 ports.

Page 68: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide C-4

Assembled kit:

Page 69: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide C-5

Kits for Unprotected Configurations

For unprotected configurations with DS3, 3xDS3, or STM-1 electrical interfaces, we use a 1.0/2.3-to-BNC adapter (1.0/2.3-to-BNC) (COAX.1.0/2.3 TO BNC STR. PLUG CABLE, 25 cm, 75 Ohm, WA-0175-0).

The number of 1.0/2.3-to-BNC adapters depends on the type of configuration and interface. For example, for a 1+0 configuration with STM-1/OC-3 electrical interfaces, one adapter is required for the site (two for a link).

Page 70: IDU Installation Guide 2007-11

FibeAir® 1500P/IP-MAX/IP-MAX2 IDU Installation Guide D-1

Appendix D: PPP/SLIP Driver Installation

Installation for Windows 2000/2003/XP

1. Click Start, Settings, Network and Dialup, Make New Connection.

2. Click Next.

3. Mark Connect directly to another computer.

4. Click Next.

5. Mark Guest.

6. Click Next.

7. Select Communication cable between two computers.

8. Click Next.

9. Select For all users.

10. Click Next.

11. Type The connection Name.

12. Click Finish.

Configuring PPP

1. Click Start, Settings, Network and Dialup.

2. Select The connection Name.

3. In the General tab click Configure, and set the speed to 38400.

4. Check Enable Hardware flow control.

5. Uncheck Modem Error control, Modem Compression.

6. Select Network tab.

7. Select Type PPP.

8. Select Internet protocol (TCP/IP) and click Properties.

9. Uncheck all options except TCP/IP.

10. Check Use the following IP.

11. Insert IP Address (the same subnet as the Indoor).

12. Click OK.

13. Click OK.