Ideas ASIC products with possibilities for use in neutron detection
-
Upload
gunnar-maehlum -
Category
Technology
-
view
600 -
download
3
description
Transcript of Ideas ASIC products with possibilities for use in neutron detection
Integrated Detector Electronics AS (IDEAS) 1
Integrated Detector Electronics AS at the
European Spallation Source (ESS)
Detector Front-end Readout and Application Specific Integrated Circuits
Products
2014-02-11
Integrated Detector Electronics AS (IDEAS) 2
IDEAS, http://www.ideas.no
2014-02-11
Integrated Detector Electronics AS (IDEAS) 3
Overview of the Presentation
Heritage of IDEAS ASICs for Science
IDEAS ASICs for Detector Front-end Readout
Public Information on the Requirements for Detectors at the ESS (from ESS website)
2014-02-11
Integrated Detector Electronics AS (IDEAS) 4
Heritage of IDEAS ASICs for Science
VA1
1992 20062002 2013
Low noise Viking ASICs
Counters,Spectral counting
SEU/SEL Radiation Tolerant
Comparators& Timing
Low power
1997
Nygard et al. NIMA301 (1991)
ALPHA ATHENA PHOBOS PHOENIX
CLEO NOMAD BELLE
PAMELA AMS1, AMS2 AGILE MEGA
SWIFT STEREO CALET
POLAR ASTROH FOXSI BEPICOLOMBO DAMPE STIX
ANKE PAX R3B
NGRM JUICE HXMT EPM
2014-02-11
ALICE BTEV CREAM
ASIM
AEGIS
Integrated Detector Electronics AS (IDEAS) 5
IDEAS ASIC Products1 Amplifiers, SH, MUX
2 Comparators, Triggers
3 Data Driven Detector Frontend Readout
4 Counters ICs
5 Current Integrators, CDS, ZDT
6 Analogue Samplers
7 Parallel ADCs and TACs
8 Pixelated ICs
9 Data Acquisition Systems (SoC)
2014-02-11
Integrated Detector Electronics AS (IDEAS) 6
Amplifiers with SH, MUX, Parallel Out
IDE1162Others:VA2VA140IDE1160, etc.
ApplicationsNuclear Physics and Astrophysics, forSemiconductors, wire chambers, PMTs
2014-02-11
Pulse height
Integrated Detector Electronics AS (IDEAS) 7
Comparators and Triggers
TA160, can be combined with VA160Combined chip is VATA160 and IDE3160
Trigger output
ApplicationsTrigger, timing
2014-02-11
Integrated Detector Electronics AS (IDEAS) 8
Amplifiers with Triggers and MUX
2014-02-11
IDE3160
ApplicationPMT readout
Integrated Detector Electronics AS (IDEAS) 9
Data Driven Detector Frontend Readout
ApplicationsIDE4183 Medical ApplicationsIDE4184 Preclinical ApplicationsIDE4281 Meier et al. Proc. IEEE NSS 2013
2014-02-11
IDE4281
Integrated Detector Electronics AS (IDEAS) 10
FE-ASIC for Event Counting with external FPGA
2014-02-11
ApplicationsMeier et al. Proc. IEEE NSS 2013
VA64TAP3
IDE3465
Parallel trigger outputs
Integrated Detector Electronics AS (IDEAS) 11
Event Counting on Chip
ApplicationsIDE3466 in Desorgher et al. RADEM for JUICE, EGU2014Similar ASICs: CA3 in Mikkelsen et al. Proc. IEEE NSS 2008, and
Schlomka et al. Phys. Med. Biol. 53 (2008) 4031 - 4047 2014-02-11
Counters
Integrated Detector Electronics AS (IDEAS) 12
Current Integrators
VASCM3.2
ApplicationsCommercial Dosimeter System in Radiation TreatmentOestling et al. Nucl. Instr. Meth. A525 (2004)
2014-02-11
2 chips bonded on flex
Integrated Detector Electronics AS (IDEAS) 13
Pixelated ICs
ApplicationsCastilla et al. (2008), Proc IEEE NSS
VATA211P
32 x 32 pixels, 300µm pitchDiagram of a pixel
2014-02-11
Integrated Detector Electronics AS (IDEAS) 14
Analogue Samplers
Preamplifier output is continuously sampled. A signal above threshold stops the sampling and samples can be read out.
IDE3421D
Ring sampler or pipeline
Technology and Applications:Gamma spectrometer and camera, Kaye et al. (UoM), Proc. IEEE NSS 2011
2014-02-11
Integrated Detector Electronics AS (IDEAS) 15
Parallel Digitization on the ASIC
ApplicationsIshikawa et al., IEEE TNS 58 (2011)
IDE3450, IDE3451, IDE3460, IDE3461
Wilkinson A/D Converter
2014-02-11
Integrated Detector Electronics AS (IDEAS) 16
Timing and Time to Amplitude (TAC)
VATA64HDR16, VASTAT
Time-of-flight (TOF)
Peak-Hold
ApplicationsBagliesi et al., Nucl. Phys. B 215 (2011) 344Zhang, He, Knoll, Wehe, Berry, IEEE TNS 52 (2005)
2014-02-11
Integrated Detector Electronics AS (IDEAS) 17
Data Acquisition System (SoC)
uCSystemMaster
digital control system
SPI
SENSADC
0 SENSADC15
AUXADC
OUTFSM
VREFVBIAS
NIRDetector
ROIC
SPImiso/mosiscsn / sck
SPImiso/mosiscsn / sck
sensor_ctrl[7:0]
SPImiso/mosiscsn / sck
clock_vector[31:0]
AOUT[15:0]
DOUT[7:0]
TempOUT[3:0]
VREF[7:0]
VBIAS[7:0]
CONTROL-MASTER16b addr / 8b data
IRQ
ApplicationsBerge et al. (IDEAS), NIRCA Abstract, submitted to SPIE Astronomical Instruments 2014
2014-02-11
Integrated Detector Electronics AS (IDEAS) 18
ESS Instrument Proposals 2012
LoKI – A Broad-Band SANS Instrument
Compact SANS Optimised for Biological Samples
nMX Macromolecular Crystallography
ODIN – Optical and Diffraction Imaging with Neutrons
2014-02-11
From http://europeanspallationsource.se/instrument-proposals-2012-0
Integrated Detector Electronics AS (IDEAS) 19
LoKI – Broadband SANS
IDEAS can provide detector readout solutions on integrated circuits (ASICs) that • help mitigating the technological risk. The solutions can involve integrated circuits (IC) off-the-shelf or existing designs • to mitigates schedule risks.
From ESS Construction Proposal LoKI, A.J.JacksonAnd Kalliopi Kanaki, 28. Feb. 2013.
2014-02-11
Integrated Detector Electronics AS (IDEAS) 20
Compact SANS for Biological Samples
Baseline: SANS2D (ISIS) and D33 (ILL) use pixel-cell detectors from ORDELA. With 1cm pitch and discrete electronics readout.
IDEAS designs ASICs for detector readout that enables • very small pixels (microns to centimeter)• reads out many channels (thousands)• reduces the cost per channel (a few EUR per channel)
From ESS Instrument Construction Proposal, Compact SANS, March 1, 2013.
2014-02-11
Integrated Detector Electronics AS (IDEAS) 21
nMX and ODIN
ASIC Detector Front-end Readout is essential for advanced neutron imaging
2014-02-11
Integrated Detector Electronics AS (IDEAS) 22
ASICs in 2D Detectors at ILL
ILL, 26.09.2013
ASICs can reduce the cost of detectors.
2014-02-11
Integrated Detector Electronics AS (IDEAS) 23
From R.H.Wilton, 14.March 2012
Detector Systems at ESS as of 2012
Next: Discussion about FEE Needs at ESS
2014-02-11