ICP Test Report Certification Packet/media/electronics_technical/...Test Report No. SH4EC1119525001...
Transcript of ICP Test Report Certification Packet/media/electronics_technical/...Test Report No. SH4EC1119525001...
1
ICP Test Report Certification Packet
Company name : Littelfuse, Inc. Product Series: 2AG Glass Body Fuse Product #: 209xxx Series
Issue Date: July 30, 2012 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components.
Issued by:
<Global EHS Engineer>
(1) Parts, sub-materials and unit parts This document covers the 2AG Glass Body Fuse RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used
Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1
Remarks:.
Form 585-047 Rev. A 2/21/06
2
Table 1: List of Raw Materials covered by this report
Total Parts Raw Material Part Number Raw Material Description Page(s) 1 087244 HMA - RoHS 3-7 2 087244 HMA - Halogen 8-11 3 692535-001 Solder 12-16 4 648106-001 Yarn 17-22 5 648115 Yarn 23-31 6 082***-001 Cu99.9MSn Element 32-38 7 910-537-3 Cap 39-46 8 910-223 Cap 39-46 9 C909-367-001 Body 47-51 10 082xxx / 082xxx-001 Cu CDA 102 Sn Plated 52-56
SGS Job No. :
Date of Sample Received :
Testing Pedod :
Test Requested :
Test llethod :
Test Rosults :
Test Report No. SHAEC1119525001 Date: 07 Dec 2011 Page 1of 5
3M CHINA LII\4ITED
222# T|AN LtN ROAD, SHANGHAT (200233)
The following sample(s) was/were submjtted and identified on behatf of the ctients as j 3M 3779-pc
sP11-036760 - SH
03 Dec 2011
03 Dec 20'11 - 07 Dec 2011
Selected test(s) as requested by ctient.
Please refer to next page(s).
Please refer to next page(s).
Signed for and on behalfofscs-csTc Ltd.
. rhlconr.rt dr dMr!,rlty r.brbdM!l![|',1|blt'c]|n|sdon.dedr'4i.lb.'.'fd!cn.gpl|ilu
,.,1s
,rt*{ *
Fan Jingjie, JJApproved Signatory
B dud rr h. 6hF4 4bLd bn c.'6ld hr 61 6rFe Ebtd b rE c.!6h. dodDd,rlFd r hr s n e'@h/orat.{.Mrit,ifi enA n ch^ ro-b-knbrd o;d;; ;6;;-rd;:;;6;;H ff 4fi ;ffi;;6;ii?6; d &; G6i;i$fiiiiuiriiiii?l;;ft'diffii;n; ;r
'rhrconr.rt !h dMllr|lty r.b
fdt!/b&Y8sftdt uoiid.srduldor! 2@zg3+l .!ii. *iE8adrr669l+3+l lf:26a3
lE&lr+tle$OZs5s lFlE{e-aF4e$Ot ffici.4rj0nH! n1)314&591 Hlr@6-21)646063 . €.!'i'€re.q
Monbor oth. SGS grup (SGg S )
Test Report No. SH4EC1119525001 Date: 07 Dec 201'1 Page 2 of 5
Test Results :
Test Pan Descriotion :
Spodm€n No. SGS Sample lD D66cription1 SHA1 1-195250.001 Ye ow sotid
Remarks :
(1) 1 mg/kg= I PPm =0.0001o/o
(2) MDL = l,tethod Detection Limit(3) ND = Not Detected ( < IIDL )(4) "-" = Not Regulated
RoHS Dir€dive 201 iA5/EU
Test l\rethod: with referenc€ to tEC 62321i2008(1) Delemination ofCadmium by tCP-OES.(2) Determination of Lead by tCp-OES.(3) Determination of Mercury by lCp-OES.(4) Determination of Hexavatent Chromium by Cotodmetric Method using IJV-Vis.(5) Determination of PBBS / PBDES content by GC-MS.
Test ltem(s)Cadmium (Cd)Lead (Pb)Mercury (Hg)Hexavalent Chrcmium (Cr(Vl))Sum of PBBSMonobromobiphenylDibromobiphenylTdbromobiphenylTetrabromobiphenylPentabromobiphenylHexabromobiphenylHeptabromobiphenylOclabromobiphenylNonabrohobjphenyl
Decabromobiph6nylSum of PBDESMonobromodiphenyl ether
ud! udr100 mS/kS
1,000 mg/kg1,000 mg/kg1,000 mg/kg1,000 mg/kg
- mg/Kg- ng/Kg- mg/kg- mg/Kg- mgfl(g- mg/kg- mg/Kg- mgKg- mgKg- mg/Kg
1,000 mg/kg- mg/kg
Ma! 0p12 N D2 N D2 N D2 N D- N D
5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D
5 N D, N D
5 N D
'aad* b rmr h. c@ '. tq ErFioir ooamrb .r n*r.oitu'm .{dM(h_.a&d,& tr &.m b-br lldabr oi$uB4t6-.Bdk,Hie .dndLn.xdhGlffi;;dF;.ffi
,. ih. conDrvr |d. dH.5 1y r.roro C r.d !d fi @iar d6! id.xffiib !.di;b I hi-did.'d.b!l!| |...uid'|h.hEd|on
b hr hd com'rk FrFiori bamrb.r 6Fr.oitu'm.{ddr h_.a&d,t tr &.h b-rrlltub. o
' / D t ' r h . c o n D f y r d . f i H & J | ' L{!hb.id.bft:rr..r und.r rh. hu|. 'd.o!l!|h.uielb.hEd|o
i rtori.r.n!.(.) ' ..bd
Membfi ol h6 SGS G.o{p (SqS S,A)
t'ctElu8Ygrsidd xdr dsid,iuahdol|tl.Ill.*icEturi|3aelts+i ll
lE&E(s-z)61{!2553 ift€(6-21)6€Sl! l*o3e3.hru{6-?11614025e4 NL06-a)5{44653 .t5.diE€F9{q
Test ReportTest ltemls)
Dibromodiphenyl etherTribrcmodiphenyl etherTetrabromodiphenyl etherPentabromodiphenyl elh€rHexabromodiphenyl etherHeptabromodiphenyl etherOclabromodiphenyl elherNonabromodiphenyl etherDecabromodiphenyl elher
Notes :
No. SHAEC1119525001
tuni.!
Date: 07 Dec 2011 Page 3 ofs
Ulit Mgt @lmg/kg 5 NDmg/kg 5 NDmg/kg 5 NDmg/kg 5 NDmg/kg 5 NDmg/kg 5 NDmdkS 5 NDmg/kg 5 NDmdkS 5 ND
(1) The maximum permissible limit is quoted from directive 2011/65/EU, Annex ll
lhrid@'i.n b d.d rrrh. co6Ftry rbj.d b r. qdsrc4rrls!or s.ftronld d,blllgbd io.'n docle'f,a*dn r.m. .nd co{drrN ft. €e
.n o,r€a'br. n!qjr!r! rt. 6i4.!4 r{ @l!4!!'!ilrir€. r.m.6d cotu ft. Ed;d. oo*tub d fr er.s;E m.ndrd.hi. ^ed & tr hh |th. iin'bd-r-d.tudhrii adbrdr.rBMd'.ddturEffiF 6ffirffi;i;6dc[ift htulnlE. ririr, rnrco@$?. ,.rr ridlbfly nbitcjrr rnrco@rf. ,0r ridlb$v I
Ddobrrrrd.uncrh.r.6.cl0n nrr&-{.r. rltull|mod'.s'b{4etfui '6o'$.*d.i ld
i rrcii. hr.(r)L.bd
t'btEr$loYdrnto d&htotttltsllccrir 2t0233FN.lll.iiEEf, dr1330+39| 11 2M3
rEtE{s-21)81,€2553 tEE€(6-2r)6'gS79 t*.Nn.4.Mh!t& 21J6t4@P1 rL{s'?rFLa653 . !s.d'iEo!p9@
Membsr ol tlra SGS Grolp (6GS SA)
Test Report No. SHAEC1119525001 Date: 07 Dec 2011 Page 4 of 5
ATTACIII,|ENTS
Rol-ls Testing Flo\ r Chart
1) Name of the p€rson who made testing: Jan S hi/yolo Wangr'A en Xiaocary Xu2) Name ofthe p€r6on in charg€ ofteging: Jeff Zhang/George Xu/ Etim Lin3) These sam ples were d isso lved t otat ty b y pre-cond iti oning met hoda cDordi ng to be tow ffow chan.
(Cr6+ and PABs/PBDEst6st method exdudeO
Sample Preparalion
Sample Measuremenl
Acid digestion withmicrDwa\€/ hohlate
Concentratio n/Dilutaon ofodradion
solution
1) Alkal iFudon /Ory Ashing
2) Acjdto dissol\E
Metal l icmatedal
Heating to 90-95Cfor extraclion
Filtration and pHadiustnent
Adding 1,SdiphenY€arbazide
de\elopmentAdding ' l ,$
diphentcarbazide
ind icates the
Pb/Cd/Hg PBBs/PBDES
iro -drll!!tub bd &!m.tr6 Ebld b thr md cdhffi 6
[email protected] Er. r.@idb rr BiorqcldhdN'elndd'rid.
ry b rb ..FPr.(.) hrbd
3'hidterdre.d&n ol,nli.dijc|i. 2ocrar34!'lt.*iEgl&l6ao+3*l ll:2o@3
rErE6-?)0110?653 lElE&"rF4o$tg md..!.cmHL(A-2',)01'&Cr r.iL{e-21)s.6dEE3 . rg5ftnD9d
M3mb6r ot rhe SGS Group (SGS SA)
Test Report
Sample pholo:
No. SHAECI' l19s25001 Date: 07 Dec 2011 Page 5 of 5
sHA11n9s250.001
SGS authenticate the photo on original report only
""' End of Report "*
'd4r ilffi b N. nd -Fr nb sry r. tu 3hpr.{.) r..bd
Daqdbr.oddlr obte b h oFdredf r 41 5k6E e6min I .h sr.Birr'hr .{oon.d}hi. Atut{; n dn;lt[aIFd oi ol
BdlgtRia..d hd'dbn E{a otud tu{i. ^ry ber.,d' tunmr I kd hr];Gifii6iEn-&.d|'lnfu-h co.e.hrr r{ns .'hnhdtlAi5rl6dqarbhhrin!d*mtrd!d.F,[email protected]!bbcr.drndh!deun.ntd-3iddoi.nbFtubrntrrdoni ' t r 5 t d ] h ! . l | t i i N b f r [ d d i | ' ' $ l . l | d d f f t r 1 d i n d l b . E 9 F d . o d . r F 9 t | n f u | l ' f | s M 0 d ' | i ' b 'fi/srdi!|@ rhQan.htsry d
3nElEbr3gYitritodxll|loitad,$|Et'otu a@3+l ..ti|.*[Allt$r.lrrtsltl lrt 2@33
lElE(S-2ll61a@5! |ESEFAj)649536?9 w*ci.60..onHL@-21)61{@e1 rt{6-21}516u853 .€id'merFm
Msnb€i ol dt6 SGS Gble {SqS s,q)
Tast Report No. SHAEC1119525002 Date: 07 Dec 2011 Page 1 of4
3M CHINA LIIVITED
222#T|AN LtN ROAD, SHANGHAT (200233)
The following sample(6) wasi/vere submitted and identified on behalfofthe ctients as :3M 3779-pc
SGS Job No. :Date of Sample ReceivedTesting Pedod :Tesl Requested :
Test Method :
Test Results :
sP11-036760 - SH03 Dec 2011
03Dec2011-07Dec2O11
Selected test(s) as requested by client.
Please refer to next page(s).
Please refer to next page(s).
Signed for and on behalfofscs-csTc Ltd.
.--),-
,/t*( Y*
Fan Jingjie, JJApproved Signatory
tiu dud 'r .sd br rh c.6Fn &b!.r b r! o-nr c.i.dEr.r sirdd.qlqs* hr, dodtun.rdt dr nmr.^r @d.d b Eh'. eErd d ,wB Fri/!.r{ .{oen.d.di' ^M-s n dfraltb.I {orol
t'EtuneY$se.dlnde4$.ddonr 2o@3t!'tl.*iEEt r||$sts+l ln:2(0aa
lElE{s-z)Ol1o2t8 IElE(l6elF{€s5a atr.ci.43imFu(6-2!61.e594 .L($-?r)5affi3 ..s..hnc&!.d,
lrombor ot th€ SCSCloup (SGSaA)
Test Report
Haloo€n
Test lrethod : With
Test ltem{s)Fluorine (F)Chlorine (Cl)Bromine (Br)lodine (l)
No. SHAEC1119525002 Date: 07 Dec 2011 Page 2 of 4
Test Results :
T€st Part Descriotion :
Sp€dm6n No. SGS Samplo lO D€6cfiption1 SHA1l -195250.001 Yellowsolid
Remarks :(1) 1 mg/kg= 1 ppm =0.0001%
(2) MDL = Method Detection Limit
(3) ND = Not Detected ( < MDL )(4) "-" = Not Regulated
reference to EN 14582: 2007, analysis was performed by lon Chromatograph (lC).
Unit
mg/kgmg/kgmg/kgmg/kg
MDL OA50 ND50 ND50 ND50 ND
ftldemd b &.d by rh. c.rtse &q-i b h. ofmrc&dlnld !d@,.,gEo* hd d..4d,r4d b rlm.ir o6idri6 k EMor. D.eMr d mcoMrB.-dM' tu- abdli n a.dr ro *ittdrldon o,t3ltzEnastql/l!l{i!.'gql+ltffill{eq!l.dlgr9 tudnc h'h aryi"k.lhb &ffitL rdrd!E ffi;Eifiaii'*-iiiaiiP|q-T5^46N@htuhtr
d.trtr,rD.cmk_qL. reh.rr.ri.&nds.bt
rEtetlgfdritud&rrirE dnfi.$aoh 2o@3 tErE€6+l)el4!55! taE6-al)t405$?9 Bci.t{.com$I.5f.h[AlttStots+ll !l:2@o3 !r!(6-rjl611@o4 H!lt6-zt)sa6K0 r€sdirorF.@
Mehbrrot lhe SGS OlouD (SGSSA)
Test Report
ATTACHMENTS
No. SHAEC1'119525002 Date: 07 Dec 201'1 Page 3 of 4
1 ) Name of the person2) Name of the person
Halogen Testing Flow Chart
who made testing: Daisy Gongin charge ofte6ting:Alex Jiang
Sample measurement
Combustion in oxygen boftb
Dissolved in an absorptionsolution
Analyzed by ionchromatography. Double conf km
by other instruments, if
rhbdtuiff | 6rd !r rh conFry rhtd b dr oddr ftrdds3 ar 5!l! rd,,!!!!r'* hn daclhublr 4- b r.nr tn! codfr b ddo. Doo|Eb !t ,N m.qtrr..fl ..
trqld & |d|# .r idt.'@rj!I!4!rt!!!!r!!_s'q!!!r!!t ffis.c.fr4.!4!d!hn ^tuiion a-h ic6nhlbii;i'r
|.sd.nndbrdi.^ryh&'dls. rn.c@rvr Fr. r.d$ Lir
dd.bl| ' . | |d.u.d.r|h.h rdlonddroit, tur. rn.c@ryr Fr. nsrdfsi.rdoflrhndrtbrhisdih
t'etEl$&lbrsto dxniudtd,gt$afl onr [email protected],t.$llEttftaetst* ll:2Mo
rE!E(S-2r)0t104!& IAEt6?1)6{S',r9 lwcr.3s"co6N!(6.?16r102!04 -L {*-n)6460cs3 . .ssd'mO69q
M6mb6rollheaqsGbup (SGgsr)
T€st Report
Sample photo:
tTr.t:ry::. D-? I'gT.i:?aq!Ke.n: j!L 1cbj
*nrbr .prdd or b. comr.iy.hrw.iMridrndnldrhrnrrr.ih..F r.(.)r..bd.
No. SHAEC1119525002 Date:07 Dec 2011 Page 4 ol4
sHA11-195250.001
SGS authenticate the photo on odginat report onty
"* End of Report '*'
l'Dt!.It6eY.l.iicdunosJdshdtorr 200233tl..ti,*iE8lurt|8ogli3qt lrl:2M3
rEtEl&2r)d14653 lElE6?lje€$da ffi .i..!.cmHli(s-zll6t@ol &ls-?l)se$ ..s.dr&F.6
Mlmb€| ol rh. scs Goup (scs sa)
T6st Report No. SHAEC1116009837 Dat€: 14 Oct 20'11 Page 1 of 5
ZHEJIANG ASIA GENEMf, SOLDERING & BRAZING I\4ATERIAL CO.,LTDXIHU INDUSTRIAL PARK,SANDUN,HANGZHOU CIry,ZHEJIANG PROVINCE,CHIM
Tho following sample(s) w€s/were submitted and identified on behatf of the ctienb as : LEAD-FREE SOLDERWIRE
SGS Job No. :
Illodel No. :
Composition :
Date of Sample Received :
Testing Period :
Test Requested :
Test Melhod :
Test R€sulls :
Conclusion :
sP11-030781 - SH
YTWl 08(692535-001,692535-002,692535-003)
Sn3.ocuRE
09 Oct 2011
09 Oct 2011 - 13 Oct 2011
Selected test(s) as rcquested by client.
Please r€fer to next page(s).
Please refer to next page(s).
Based on the performed tesls on submitted sampl€s, the rcsulls of Lead,[,lercury, Cadmium, Hexavalent chromium, Polybrominated bipheny's (PBB),Polybrominated diphenyl€th€rs (PBDE) complywith the limits as set by RoHSDafective 201 1/65/Eu Ann€x ll; recasting 2002/95/EC.
Signed for and on behalfofscs-csTc Ltd.
zQr'"^Fan Jingjie. JJApproved Signatory
rlt d ro r! c'{i c.dtrm.r lrrloM rM bl*ee hr e.!ffo .{dmd5ffIE&fit a_aEilttir',ilii;h o,
d!' ddbsdl'dbib ^ rGffiEEffrlE-fi;Edtl$hfrld||aldslrfuo{|l&iE rd olro.rhr udr rh! t nuc nNd!€d .r6Dr ri turlrirrros rdorrihi | | 'os'doltih.|,F0llo'f i.c06'.tr}
r{ub ris h fr d rFn rtu rrrr rb.5ht.{.) rrbd
f harysi9Y|nu&tuUlttshrfi Ct|| 2(@3+1.I'1.$E8e!tm39!13!}1 ln 2@3
rE{€6.a}6!@55rrErE6-aF45S79 F.6r$dllL{d-21}01402P1 Hj0l-z)5r60(63 ..Fd'bo{fm
M.mb.r ol rhr SCg qrouD tSOgS )
Test Report
Test Results ;
No. SttAECl l16009837 Date: 14 Ocl 2011 Page 2 of 5
Test Part Desc.iotion :
Sp€dm€nNo. gcssamplelD D€crlptm'l SHAI1-160098.032 Situerymetalwire
{1) 1 mg/kg = 1 PPm = 0.0001o/o(2) MDL = l'rethod Detection Limit(3) ND = Not Detected ( < MDL )(4) "-" = Not Regulated
RoHS Dtrc.d\'6 201 165/EU
Test Method: With reference to IEC 62321:2008(1) Determinalion of C€dmium by ICP-OES.(2) Oetermination of Lead by ICP-OES.(3) Determination of lllercury by ICP-OES.(4) Determination of Hexavalent Chrcmium by Spot lest / Colorimetric l\,,lethod using UV-Vis.(5) Determinalion of PBBS/ PBDES by GC-[,IS.
Test ltem(s)
cadmium (cd)
Lead (Pb)
Mercury (Hg)
Hexavalent Chromium (c(Vl))Sum of PBBS
DibromobiphenylTribromobiph€nyl
Sum of PBDES
Monobromodiphen),1 etrer
tbi! ud!100 mg/kg
1,000 mg/kg1,000 mg/kg
'1,000 mg/kg- mg/kg- mgl(s- ms,4(s- ms4(s- mgfts- mg/ks- ms/kg- mg/ks- ms/ks- mg&g
1,000 mg/kg- mg/kg
MDt 0322 N D2 1192 N O
. N D
5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D
5 N D5 N D- N D
5 N D
| .ii olrhttrs. udr u'. h'drotr d
lbrl|$0rtnu)drr*au,tr{aoh a@33'Fl .tr:.lilBttrl€3e+8rtt In ra@3
rEE(6-A)daoE5drE!E(6-?rF466'! h.dj!r.mllrr(i-21tar]Gaa frtD-zFm3 .!0*6ire.t6
Mon$rol1noSOACoup(SOgS )
T€st ReportTesl ltem(s)
Dibrcmodiphenyl ethe.Tribromodiphenyl etherTelrabromodiphenyl etherPentabromodiphenyl elherHexabrcmodiphenyl elherHeptabromodiphenyl etherOclabromodiphenyl elh€rNonabromodiphenyl elherDecabromodiphenyl ether
No. SHAEC'1116009837 Dater 14 Oct 2011 Pag€ 3 of5
L!!!! ui!mg/K9
mg/Kgmg/|(g
mg/ksmg/kgms/kgmg/ksms'&smsn<s
f hee|nigY|trndl1r|rllsq8|flBcrf 2@33+1.-Ll.*iEE'ldrl!3e!l3tl ll 2@3
MDt555555555
032NDNDNDNDNDNDNDNDND
[b d,b!!Mt Mi @.mtr dsr bRn-o d #.,r.6iem ..0.dtr!ffiih.'6i'L-ffiiE6;rantui crh4rt--i!{{i.di.'!.ertuadEorh'h.rryd,c"trkr''hdldsr-rft|"idcl'ffiblf-nrdifiE!$h s hr.
m d d c . n m | u d ' | i . h i n d o d 0 n . r n h d o m f l n d b [ F l d {
(1)The maximum permissible limit is quoted from directive 2011/6tEU, Annex ll(2) " spol-test:Negative = Absence of CrVl coating, Posilive = Presence of CNI coating;The test€d sample should be turth€r verified by boiling:water-exl.aclion method if ths spot t€st rssuh isNegative or c€nnot be confmed.o Boiling-water-extraclion:Negative = Absence of CrVl coaling; Positive : Presence of CrVl coatingThe detected concentration in boiling-wateFexlraction solution is equal or geater than 0.02 mg/kg with 50cm2 sample surface area,For conosion proteclion coatings on melals: Information on storage conditions and produclion dal€ of thetested sample i6 unavailable and thus results of C(Vl) epresent status of the sample at the time of
bturr.r.(.lr.hd
rEr€(d.l)dra63 r€aE&erlae'/g ft.6.4rmHi(a-A)tt@4 ri,{!d"l}sel . !$dn!.€Dd
M€mb* or rh. scs Gloup tscs sa)
sGqTest Report
ATTACHMENTS
No. SHAECI116009837 Date: 14 oct 2011 Page 4 of5
&qd b [! ornr cdr!{ ot s6tuh&..qj!!!d. ffi.i tuib,&qd E rdd ri coldb6b ad .ndid6. atLit, |d||fi-rtbiBd,q d
RoHS Testing Flow Chart
1) Name of lhe person who madetestingtJan Sha/Yoyo Wang/Atten Xiao/GaryXu2) Name of the person in charge of testing: Jeff Zhang/ceorge Xu/ Etim Lin3) These samples were dissolved totally by preconditioning method accordjng io belowflow chart.
(Cr6+ and PBBS/PBDE8lest method excluded)
ricb'd*hildrdrdhrtnffi € i a6ard6-6B;rirMdbrhud,6
tdi! hd snFb. fd.r 'b hrdtF.rdlqdrr.eroidrblqtu'lna6.Mhfrbnotsnrb
tbttlticwrftdrrd($rghdctr 2oo233+1.4.*iEAtdrl$a+eei 1|: 2m33
r ElE (B-2r)d1a@sr I e& c6-21)n1l53d79H!(C-Zt6r4@. irt6.Z)5rffi . $.d'rtt F@m
Sample Preparalion
Acid digeslion withmicrowave/ hotplate
Concentralion/Dilution of extraclion
solution
1) Alkali Fusion /DryAshing
2) Acid to dissolve
tcP-oEs
Filtration and pHadjuslment
Adding 1,5-diphenylcatbazide
for colordevelopmenl
Adding 1,5-diphenylcarbazide
development indicates lhe
conlim with
Pb/Cd/Hg PBBs/PBDES
Menber ot fi. 9OS Goup {SGS SA)
Test Report
Sample pholoi
No. SHAECl l'16009837 Date: 14 Oct 2011
sHAl 1 -160098.032
Page 5 of 5
rEsE(s-A) {Pssa rE €(63)6a05a61tHL(c-211614!!r4 Hj(B-21'54!63 .t!.d'irg|.9@
SGS aulhenticate the pf'oto on o ginal rcport only
"' End ol Report '*'
*qer ro h c.mnr coidtrer or sntu,a4d-b btrr mr cd6iqor' dd
ft! ttureD ltu.r dhd hr4ri. b, icnrrltb! enrd k &n.d 'MrEGi66i-.rihdi.trfu-r nti.*ndb!u,odior
qlib id dntsls. rder rb b.6dtrF.r4'4dhHeroidrb$nb
Memb€rollhsSGSGlouo(scss )
Test Report Number : TWNC00233542
Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited
K. Y. Liang Director
This report shall not be reproduced except in full, without the written approval of the laboratory.
Page 1 of 6 Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Applicant: Littelfuse Philippines Inc. Date : Nov 25, 2011 LIMA Technology Center, Lipa City,
Malvar, Batangas
Sample Description:
One (1) group of submitted samples said to be : Part Description : Yarn Part Number : 648106-001 Date Sample Received : Nov 21, 2011 Date Test Started : Nov 22, 2011
Test Conducted :
As requested by the applicant, for details please refer to attached pages.
Number : TWNC00233542 Test Conducted
Page 2 of 6 Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
(Ⅰ) Test Result Summary : Result (ppm)
Test Item White Yarn
Heavy Metal
Cadmium (Cd) content ND Lead (Pb) content ND Mercury (Hg) content ND Chromium VI (Cr6+) content ND
Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) ND Dibrominated Biphenyls (DiBB) ND Tribrominated Biphenyls (TriBB) ND Tetrabrominated Biphenyls (TetraBB) ND Pentabrominated Biphenyls (PentaBB) ND Hexabrominated Biphenyls (HexaBB) ND Heptabrominated Biphenyls (HeptaBB) ND Octabrominated Biphenyls (OctaBB) ND Nonabrominated Biphenyls (NonaBB) ND Decabrominated Biphenyl (DecaBB) ND
Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) ND Dibrominated Diphenyl Ethers (DiBDE) ND Tribrominated Diphenyl Ethers (TriBDE) ND Tetrabrominated Diphenyl Ethers (TetraBDE) ND Pentabrominated Diphenyl Ethers (PentaBDE) ND Hexabrominated Diphenyl Ethers (HexaBDE) ND Heptabrominated Diphenyl Ethers (HeptaBDE) ND Octabrominated Diphenyl Ethers (OctaBDE) ND Nonabrominated Diphenyl Ethers (NonaBDE) ND Decabrominated Diphenyl Ether (DecaBDE) ND
Halogen Content Fluorine (F) ND Chlorine (Cl) 591 Bromine (Br) ND Iodine (I) ND
Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected
Responsibility of Chemist :Irene Chiou / Kevin Liu / Cathy Chen
Date Sample Received : Nov 21, 2011 Test Period : Nov 22, 2011 To Nov 25, 2011
Number : TWNC00233542 Test Conducted
Page 3 of 6 Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
(Ⅱ) RoHS Requirement: Restricted Substances Limits
Cadmium (Cd) Content 0.01% (100ppm) Lead (Pb) Content 0.1% (1000ppm) Mercury (Hg) Content 0.1% (1000ppm) Chromium VI (Cr6+) Content 0.1% (1000ppm) Polybrominated Biphenyls (PBBs) 0.1% (1000ppm) Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material.
(Ⅲ) Test Method:
Test Item Test Method Reporting Limit
Cadmium (Cd) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Lead (Pb) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Mercury (Hg) content
With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Chromium VI (Cr6+) content
With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer.
1 ppm
Polybrominated Biphenyls (PBBs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary.
5 ppm
Polybrominated Diphenyl Ethers (PBDEs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary.
5 ppm
Halogen Content With reference to EN 14582:2007 by calorimetric bomb with oxygen and determined by ion chromatography
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
Number : TWNC00233542 Test Conducted
Page 4 of 6 Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
(Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008
Remarks: *1: List of Appropriate Acid:
Material Acid Added for Digestion Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected.
Sample preparation
For different material, digest the sample with appropriate acid*1
Make up with deionized water
Cd/Pb/Hg
Analyzed by ICP-OES
Weigh sample and add alkaline solution
Definite temp. extraction
Make up with deionized water and add diphenyl-carbazide solution
Cool and filter the extract
Cr6+
Weigh sample and add organic solvent
By Soxhlet extraction or Solvent extraction
Concentrate the extract and make upwith organic solvent
PBBs/PBDEs
Analyzed by UV-VIS
Analyzed by GC-MSD
By spot test
Get 50cm2 sample
By boiling water extraction
Metal Polymers / electronics
Negative *2
Confirm the tested samples are totally dissolved
Take sample and immerse into Aqua Regia, start to strip plating layer
Stop the stripping procedure upon color change completely
Take the Aqua solution as plating component and stripped body as substrate component
For non-metal part For metal part
Number : TWNC00233542 Test Conducted
Page 5 of 6 Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
(Ⅳ) Measurement Flowchart:
Test for Halogen Content Reference Standard:EN 14582
End of Report
Add absorbent in a combustion flask & place weighed sample in equipment
Fill oxygen into calorimetric bomb
Ignite then leave the flask at room temperature
Transfer the absorbent into a volumetric flask
Make up with deionized water
Sampling/grinding or cutting
Analyzed by ion chromatography
Number : TWNC00233542 Test Conducted
Page 6 of 6 Intertek Testing Services Taiwan Ltd.
8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓
Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401
Photo
Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00299967
PREPARED AND CHECKED BY: AUTHORIZED BY: FOR INTERTEK TESTING SERVICES FOR INTERTEK TESTING SERVICES LTD., SHANGHAI LTD., SHANGHAI
MYRA LV STEPHEN TSANG CHEMICAL LAB SENIOR MANAGER GENERAL MANAGER
PAGE 1 OF 9
APPLICANT: LITTELFUSE,INC. DATE: JAN 18, 2012 800 E. NORTHWEST HWY
ATTN: A. CESISTA/ K. BACILA
SAMPLE DESCRIPTION: One(1) Submitted Sample Said To Be White Yarn. Part Description : Yarn. Part Number : 648115. Date Sample Received : Jan.11, 2012. Date Test Started : Jan.11, 2012. ***********************************************************************
TESTS CONDUCTED: AS REQUESTED BY THE APPLICANT, FOR DETAILS REFER TO ATTACHED PAGE(S)
**********************************************************************TO BE CONTINUED
Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00299967
TESTS CONDUCTED
PAGE 2 OF 9
1 (Ⅰ) Test Result Summary :
Testing Item Result (ppm)
Halogen Content Fluorine (F) ND Chlorine (Cl) ND Bromine (Br) ND Iodine (I) ND
Remarks: ppm = Parts per million = mg/kg ND = Not detected
Responsibility Of Chemist :Ken He
(Ⅲ) Test Method:
Testing Item Testing Method Reporting Limit
Halogen Content With reference to EN 14582:2007 by combustion flask with oxygen and determined by ion chromatography
50 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample **********************************************************************
TO BE CONTINUED
Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00299967
TESTS CONDUCTED
PAGE 3 OF 9
(III) Measurement Flowchart:
Test For Halogen Content Reference Standard: EN 14582
**********************************************************************TO BE CONTINUED
add absorbent in a combustion flask & place weighed sample in equipment
fill the combustion flask with oxygen
ignite then leave the flask at room temperature
transfer the absorbent into a volumetric flask
make up with deionized water
sampling/grinding or cutting
analyzed by ion chromatography
Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00299967
TESTS CONDUCTED
PAGE 4 OF 9
2 (I) Test Result Summary :
Testing Item Result (ppm)
Heavy Metal
Cadmium (Cd) content ND Lead (Pb) content ND Mercury (Hg) content ND Chromium VI (Cr6+) content ND
Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) ND Dibrominated Biphenyls (DiBB) ND Tribrominated Biphenyls (TriBB) ND Tetrabrominated Biphenyls (TetraBB) ND Pentabrominated Biphenyls (PentaBB) ND Hexabrominated Biphenyls (HexaBB) ND Heptabrominated Biphenyls (HeptaBB) ND Octabrominated Biphenyls (OctaBB) ND Nonabrominated Biphenyls (NonaBB) ND Decabrominated Biphenyl (DecaBB) ND
Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) ND Dibrominated Diphenyl Ethers (DiBDE) ND Tribrominated Diphenyl Ethers (TriBDE) ND Tetrabrominated Diphenyl Ethers (TetraBDE) ND Pentabrominated Diphenyl Ethers (PentaBDE) ND Hexabrominated Diphenyl Ethers (HexaBDE) ND Heptabrominated Diphenyl Ethers (HeptaBDE) ND Octabrominated Diphenyl Ethers (OctaBDE) ND Nonabrominated Diphenyl Ethers (NonaBDE) ND Decabrominated Diphenyl Ether (DecaBDE) ND
**********************************************************************TO BE CONTINUED
Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00299967
TESTS CONDUCTED
PAGE 5 OF 9
Remarks: ppm = Parts per million = mg/kg ND = Not detected
Responsibility Of Chemist :Dent Fang / Ken He
(II) RoHS Requirement:
Restricted Substances Limits Cadmium (Cd) Content 0.01% (100ppm)Lead (Pb) Content 0.1% (1000ppm)Mercury (Hg) Content 0.1% (1000ppm)Chromium VI (Cr6+) Content 0.1% (1000ppm)Polybrominated Biphenyls (PBBs) 0.1% (1000ppm)Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000ppm)
The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. **********************************************************************
TO BE CONTINUED
Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00299967
TESTS CONDUCTED
PAGE 6 OF 9
(III) Test Method:
Testing Item Testing Method Reporting Limit
Cadmium (Cd) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Lead (Pb) content
With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Mercury (Hg) content
With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.
2 ppm
Chromium VI (Cr6+) content
With reference to IEC 62321 edition 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis spectrophotometer.
1 ppm
Polybrominated Biphenyls (PBBs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary.
5 ppm
Polybrominated Diphenyl Ethers (PBDEs)
With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when necessary.
5 ppm
Remark: Reporting limit = Quantitation limit of analyte in sample
DATE SAMPLE RECEIVED : JAN.11, 2012 TESTING PERIOD : JAN.11, 2012 TO JAN.13, 2012
**********************************************************************TO BE CONTINUED
(IV) Measurement Flowchart:
Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00299967
TESTS CONDUCTED
PAGE 7 OF 9
Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC 62321 edition 1.0:2008
**********************************************************************
TO BE CONTINUED
sampling/grinding or cutting
weigh sample and for different
material, digest the sample with
make up with deionized water
Cd/Pb/Hg
analyzed by ICP-OES
weigh sample and add alkaline solution
definite temp.
make up with deionized water and add diphenyl-
carbazide solution
Cr6+
weigh sample and add organic
soxhlet extraction or
solvent extraction
concentrate the extract and make up with organic
PBBs/PBDEs
analyzed by UV-VIS
analyzed by GC-MSD
spot test
get 50cm2 samples
boiling water extraction
metalpolymers / electronics
negative*2confirm the tested samples are totally
dissolved No
cool and filter the extract
Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00299967
TESTS CONDUCTED
PAGE 8 OF 9
REMARKS:
*1: List of appropriate acid: Material Acid added for digestion Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4
*2: If the result of spot test is positive, Chromium VI would be determined as detected. **********************************************************************
TO BE CONTINUED
Intertek Testing Services Ltd., ShanghaiTFH Division Block B, Jinling Business Square,No.801 Yi Shan Road, Shanghai, China, 200233 Tel: +86 21 6120 6565 Fax: +86 21 6127 9740 www.intertek.com www.intertek.com.cn China Toll-Free: 800 999 1338
TEST REPORT NUMBER: SHAH00299967
TESTS CONDUCTED
PAGE 9 OF 9
**********************************************************************
END OF REPORT
scsI
Test ReportPOLYFIL AGOBERALLMENDSTMSSE 2OA,
was/w6re submitted and identified by/on behalfofthe client as:
Validit nownForQueStiPlease Co ith scs
No. : CE/2011/84950 D e | 2011112101
CH€3OO ZUG / SWITZERLAND
Cu99.9MSn'1'14595
2011t1lt25201 1t11/25 rO 201I |1',01
Page: 1 or 7
rr|| [ltt!|||tlt[t
The following sample(s)
S€mple DescriptionBuyer/Order No.Sample Receiving DateTesting Period
lest Result(a) Plea6eefer to next page(s).
prqt iadsd Ds Gn ,epd eind bComFiy -r ,: !;t lLr. . . i ; l :r l i l l{ i l rt lrd r qti ' r^rl l i9i: l+,11\- em+,i , -,:r. ift",rl.
.ysuq8d b b cs€rcond rbns d ssubrd lo Tems ad cd@ l.l:
o n L y a i d w l h L n h . t m B d c | € d l n !
E d ftr|tld
clsnH L.Do'|b.t - Trhd
Test ReportPOLYFILAGOBERALLI\4ENDSTRASSE
T66i R.6ultls)
PART t.lAME No.1
No.: CE/2011/84950 Dale :2O114ZO1
2OA, CH63OO ZUG / SWITZERLAND
Page'.2 of 7
t I] t l
SILVER COLORED METAL WIRE (INCLUDING THE PLATING LAYER)
Te3t lt6m(s) Unit Method MDLR.3ultNo,l
Cadmium (Cd) mg/KgWith reterence to IEC 62321r 2008 andperfomed by ICP-AES.
n.d.Lead (Pb) mgKg 24Mercury (Hg) mS/kS n.d.Hexavalent Chromium Cr(Vl) With reference to IEC 62321: 2008 and
pedormed by Boiling \r€ter ext€ctionMethod.#
Negative
Sum of PBBS
mgikS With reference to IEC 62321: 2008 andperfomed by GC/MS.
n.d.Monobromobiphenyl 5 n.d.Dibromobiphenyl 5 n.d.Tribromobiphenyl 5 n.d.Tetrabromobiphenyl 5 n.o.Pontabromobiphenyl n.d,Hexabrcmobiphenyl 5 n.o.Heptabromobiphenyl n.d.Octabromobiphenyl 5 n.d.Nonabrornobiphenyl 5 n.d.Dec€bromobiphenyl 5 n .d .Sum of PBOEa n.d.Monobromodiphenyl ether n.d.Dibromodiphenyl ether 5 n.o.Tribromodipheny! ethe. 5 n.d.Tetrabromodiphenyl ether n.d.Pentabromodiphenyl ether n.d.Hexabrcmodiohenvl ether 5 n.d.Heptabromodiphenyl ether 5 n.o,Octabromodiphenyl ether n.o,Nonabromodiphenyl ether 5 n.d.Decabromodiphenyl ether 5 n.d.
eGlG{d rh s ied @d €nrclb Bpdcn€ry 'l+ !r ! rlrl . .n 1!ts,:r1,rtilr. ;l'!l* rrn . imri+Al'r-\r jrl4.f4! 1r€11hsdocmdssdby'h€c.mpany&bldlobcffi6|codibGo's*to. e.d'mc romal dmstu suq
d ^ t ' n d w l h L n h r m B d c r . d ! n d p o B d r t s t o G c s r a n d r h 3 d Mldrrgh6add]Ed'on6un6lh6'm
t',i!r: :d, dri:_ 11rs6rorPre
Test Report No. : CE/2011/84950 Date | 2011h21O1 Page: 3 of 7
tl]tIlltltfltttltPOLYFILAGOBERALLMENDSTRASSE 2OA, CH€3OO ZUG / SWITZERLAND
Test ltem(s) Unit method MDLResultNo.1
HalogenHalogen-Fluorine (F)(CAS No.: 14762-94-8)
mg/Kg With reference to BS EN M5A2,2007.Analysis was perfomed by lC.
50 n,o,
HalogenChlodne (Cl)(CAS No.: 22537-1s1)
50 n.d.
Halogen-Brcmine (Br)(CAS No.r 10097-32-2)
50 n.d.
Halogen-lodine (l)(CAS No.i 14362-44-8)
50 n.d.
Note :1. mg/kg = ppm : 0.1wf/6 = 1o00ppm2. n.d. = Not Detected3. MDL = Method Detection Limit4 - " - "=No tRegu la led5. '" = Qualitative analysis (No unit)6. # = a. Positive means the presence of CrVl on the tested areas
b. Negative mgans the absence of C l on the tested areasThe dgteci€d concentration in boiling-lvater-ext€ction solution is equalor greaterthan 0.02 mg/kg with 50 cm,tested areas.
7. The sample(€) was/wer6 analyzed on behalfof the applicant as mixing sample in one testing. The above result(s)was^^/€re only giv€n as the informality value.
'nrhstar€Fnd€f ontrorbsmpq3)Idd rhEbd,etsn6ndbGComFny f l t r , l r i 9 ! r . , r l i ] l : r r ! l { : : l : : ; l i ' ! i : l j i A r i i F -5 ! , [ 1 ' e t r ; ' f ' , , ' l ] l t ) [ l i 1 'n3dumd ts6su6d ' l hscomtsny5u*db t csccond1 t r sds
sib iv 6 10 6 o er 5d b6 @mntft,ltrrsandd odd3undrth€ta mol & €pdud depr 'n ju r, ftd
+l r l *J l : r (+s610r ) re t7e f +sitlfuirL!{:,r rr ir: i - i.hsror
IlF
Test Report No. : CE201'1/84950 OaL .2011h2,01 Pager 4
according to belo\ / flo /
POLYFILAGOBERALLMENDSTRASSE 2OA, CH63OO ZUG / SWITZERLAND
1) These sample6were da66olved totally by pre-conditioning methoda Cf' test method excluded )
Name of the pe6on who made measurement: Climbg€at YangName ofthe pe6on in charge of measurement: Troy Chang3)
ICP-AES
Sample Material Dige€tion Acid
S1eel, copper, aluminum, sold€r Aqua regia, HNO3, HCl, HF, HrO,
Glass HNO3/HF
cold, platinum, palladium, ceramic Aqua regia
Silver HNO3
Plastic H2SO1, HrOr, HNq, HCI
Othe.s Any acid to totral digestion
ii. irei,.or if *q oy t . cop-r " ,g .oo-maa"J ' * .6b i " - ' *dco^d ' * "6 .Edrcn ico@isbdM!os@]bi.*ddb" -'d l,nsdd 6 *,* i5r
*l iq:i";* @"* -;d.." **o.ooissr,s.ry - r"
"rd;^ a * -nd .
rtf:r:: r1lirtii+ 1l i s6 io,t,e tTe t r s lo:)2e 'r7 ffiar(om
Acid digestion by suitable aciddepended on difierent samplemderial (as belo\ , iable)
Micro\rave digestion with
HNO/HCVHF
Heat to appropriat€
temperature to e,\tract
Cool, filter digestate
through filter1) Alkal iFusion2) HCltodissolve
at 540 nm by UV-VIS
Test ReportPOLYFILAGOBERALLI\4ENDSTRASSE 2OA,
No. : CE2011184950 Oale'. 201 lh2lo1
CH43OO ZUG / SWITZERLAND
Page: 5 of 7
t l | l [ ] | | I t t | l
PBB/PBDE1) lllanE of the person2) MnE of the person
analytical FLOW cHARTwho nEde npasurenEnt: Ronran Wongin charge of nEasurenent Troy Chang
Scrcen analysis
" " " " " 1 " " " " " "
Sanple extraction/So*rlet rEthod
ConcentratdDiluteE)dracbd solution
First testing process -----t
Optional screen process -.--
Confinmtion process - .>
-s."pb---_-]--------r-------[S-r-tp]-j-a"arn"-_l-----r----
Ft ler
Analysis by GC/liS
cm€ry r r ' r j l j r ) t r . : r i l i " . : . l ! i * i , ; i i l ' r l t : e l . t i l : i l r t / . 1 \ ' l r Fn . r ' j : 1 . ' t l 6+
to €sd'o'c ramd dm6tu suq
d^t ,nd vihin rb rmis ot cr€d s i3'lbr.ohbadd€donsu.ddsera od b. repdued eiceol itul wiher
! idsnrzorNe-tu!acirrrer/*l:r/f,!.r +!!4J1i:irlre 02)r!e
I
Test ReportPOLYFIL AGOBERALLMENDSTRASSE
No. : CE/2011/84950 Daie | 2011h21O1
2OA. CH-6300 ZUG / SWITZERLAND
Analytical flow chart of halogen content
1) Name of the p€rson who lmde rneasuredEntr Rita Chen2) llan€ of the person in charge of nEasurerEdt: Troy Chang
Page: 6 of 7
comoad N]r]F,j!:ir.. I tiir lt{!l; ;]]rltl.1!- . r. irtsih-{} I 11 FiT . f!l r19i!+l
fi"JHl"l;liiii',i!',i.iwi;c"ry"';ti"-"c*""tc"t.^a sriu*-t i*n d..",; ''jbl.n bi... .d c.d*" 6, €. a " ' ' i i a - - o e , " a a . ^ * * ' ; . n b a d " i s d l b d i b m a i o ; d k . d h ;
; ; ; q ; ; ; ; oo ,4a t ; . : 6 . ? .€6@- -hsd ; "db . - "b1 .
r L - I I i d l L a i
Sarple pretreatrnent / Separation
Weighting and putting safipte in cell
Orygen Bomb Cofibustion / Absorption
Dilution to fixed volurne
Analysisw€s perfornEd by lC
Test Report No. : CE/2011/84950 D€te 2011h2101 Paget 7 of 7
tl] tlt II][]lPOLYFILAGOBEMLLMENDSTRASSE 2OA, CH63OO ZUG / SWITZERLAND
* The teeted sample / pa is maaked by an arrow if ifs shown on ih€ pholo. '
" End of Report -
€(s) r6rd Th€ r6d rop.n @nd b rccomtsry rirl,,iirar.rr'ir,'r,:111!!1, iilrRj:itr r.il1' l:!11.!-em+iI, ra r';)n:ll 'Thsih{.d"**dbylh6c"np.nysub'db6G4€Ejcond1bngo{sld ,M6.6al &dmsfu' sub]rendir,e'@ d ru d dbn s€s ibrh€! n reieds rhe cmp8.r's t ndn$ 3r rhe-y .d fu " t h " i . 6dc " " c ' * dDc . {5ny r ' j e cdnF i ys9s . s$;nshisandobroa,o3@do,rbta mdsrepd@sxepr'nlu.wM,sio,MtenaFro!3 drhecompanv a
DONGGUAN CITYXINHA] METAL PRODUCTS CO,,LTDfST WEIMING ROAD HENGZENG AV.XINAN COMMUNITY CHANGAN TOWN DONGGUAN CIryGUANGDONG PROVINCE
The following sample(s) was/lvere submitted and identified on behalf of the clientE as : FUSE CAp
Test Rgport
SGS Job No. :
Compositjon :
Date of Sample Receiv€d :Testing Poriod :
Test Requested :
Test l\rethod :
Test Results :
Condusion :
No. SHAEC1119466001 Date: 13 Dec2011 Page I of4
sPl'1-036355 - SHH6502 Dec201l
02Dec2011-06Dec2011Selecl€d test(s) as requested by ctient.Please refer to next page(s).
Please rcfer to next page(s).
Based on the per{ormed tests on submitted samples, the results of Lead,lvercury, Cadmium, Ho/€valent dlromium comply with the limits as set by RoHSDiredive 201 1/6tEU Annex ll; recasting 2002/95/EC.
Signed for and on behalf ofscs-csrc Ltd.
7QvFan Jinqjie, JJApproved Signatory
rhtr dqj|Jd rr.&dbr|n. c.q'r &qdbb o.nm cdno.or 3slrq.s b Lrtrr rd c.dffi r.r.!6m. o.@isr n s.ruttvr4.{eid.hffinitu b-F-t4trjtui.r
eM' d-r id .;riL de'ib r h-d-& r.r d.i.* hr*r ^.Yh.tdr
r id .6ri! ddr-br h---D.ote.rb.hdr{rt q..ddddNt.nrl'otum^t*i.lb..!.q!ron.rdrtintuL rhodrddr|h.n.ooe.l.l$.conr.ry
r.nd d.id.{ i.v b. rF.Ei.d 'orh. Mai.nd d s. rha6.l$fih 6rbiqdnr.r-rrbh r,r.h)bn.
hllron.rdrrintulr, rhod rdd r|h.n.ore.r .l$. Coq
Mombo. or ths SGS Grotl! (SGS 8A)
Iurynlal|n@&rit].|i{9rCiorr 2OOAatl ..Ll.*[BldllisetsBl ln 2ca2B3
lElElE-A[€Stg swcnl..mHr(&"1Fa&13 ..Fd'FO!@
I ErE {6-?r)Elr{!!aHlr (!-2t 0l l&94
Test Report No. SHAEC1119466001 Dale: 13 Dec 2011 P€ge 2 of 4
Test Results :
Test Pad Descriotion :
S@mfi No. SGS Sgmptq lD D€cription1 SHA11"194660.001 Sitver metat base part
Rema*6 :(1) l mgftg= 1 ppm=0.0001%(2) MDL = tdethod Det€ction Limit(3) ND = Not Deteded ( < t DL )(4) '-" = Not Regulated
RoHS Oir€.tiv€ 20t t/AtEU
TestMethod: Wth reference to IEC 62321:2008(1) Detennination ofCadmium by tCp-OES.(2) Determination of Lead by tCp_OES.(3) Determination of Mercury by lCp_OES.(4) Determination of Hexavatenl Chromium by Spot test / Colorlmetric l\rethod rjsing uv_Vis.
Test ltem(s)Cadmium (Cd)Leed (Pb)Mercury (Hg)Hexavalent Chromium (Cr(Vj))
rrpl @12 N D2 62 N D
llllrt100
1,0001,000
ud!mgksmgKgms/ks
Negalive
Notes :(1) The maximum pe.missible limit is quoted from direciive 2011l65/EU, Annex ll(2) o: a. Positive means the presence of CrVl on lhe test€d are€sl
b. Negativo mean6 the abGence of CrVl on the tested areasFor cono.ion proteclion coatings on morars: Information on storage conditions and production date of
the tested sample is unavailable and thus resutts of Cr(Vl) represent status of the sample at the lime oftesting.
iIt&/t oYta tod&rlrord4tu$aarrfr..tt.*rqttft8o+39t il
tE E($-2t)61a02553 tE €(s-aFaSD ffio..!.,MHi(d-a)614&9a HL6-A)5a6dB! .!ar.d*.6!.tr
@3M
Momb.r ot d|€ 8OS GtuD (8OS s^)
Test Report No. SMEC1119466001 Dato :13Dec2011 Page 3 of 4
u6.lm hl* M-rdDtrdr,bh rDD.h j,!!d
ATTACHMENTS
RoHS Testing Flow Chart
lllj:T9 ol llte eerson who made testing: Jan Shi/yoyo wang/A en Xraoz) Nahe ot the,person incharge of teshng: Jeff Zh€ng/ceorg; Xu
";:iil"ff#rji:,ffi::,aissdved totia y by pr+condiaionins-merhod accordins to betor/ fiow chart (Cr6.
.h! domd 'r ud br rD c.rts ka.dhnhdersl!tnl!44!@_!!!1ffim., &ffi.rdd b r.m. hr cd.|@ & Ebdi'c Do6i.;it;;ii ;-, ;ni;;; ii;:fi;ilffiii?ffifi#ffiffii
sthmw_rd.*r raan. rm n c@,. d...on r -rm,.n;;h* ;.-.^_,um_d srxrb.ddf, rr t mco fr..o.iddr,br-**ddmo..ryh@k_i.cbh.hdi*hddtrj,;.
Pb/Cd/Hg
Negative
1) Alkali Fusio. /DryAshing
2) Acjd to dissolveAdding'1,5-
diphenylca.bazide forcolor development
Adding1,5-diphenylcarbazide
for colordevelopment
A red color indicatesthe prosence of Cf*.lf nec€ssary. confirm
f6ru$el|f hdrt|, dam.'doi. 2o@3Fl 'Il.gi!Ai|lll839.te!t|t t* 2@6
rfrE(s+)tr.(,553 tElE6-2tl6rF5$r9 w6.!,.@iH!(&-zl6146ea Hi{*-aF.ffi .raF-d,lao']m
M6mb$ ol th6 SQS Grolo IAGS SA)
_sc$Test Report
Sample photo:
sHA11-194660.001
SGS aulhenticate the photo on originat report only'.* End of Report *"
.r r!a!-!!!!s!tta!{od".nlai. ab. I d" "
.6*. h-b.;n,br o r d
pirmdobledb*re.rhorm$ orblpered!{.d6lrrn u.*i$;ni:d;;rb;;pi;;rtii.coho!ryRtr 6$4d hHisbi d,Fods i Mi,id or.id.trin:y b. c,o..cuisjos,idr;:i.;i;ioiri, _
i rrdrhr.mr !(,)'.rbd
: 3',etE&.t&Ysl$ R!dx! oatitsh'{li oeI +t.tN.C,r€fllJ*8es935& !r.:
No. SHAECl119466001 Date: 13 Dec 2011 Page 4 of4
2!0233 rE*(re-Z)6irOtSSr te$rlt 21)6.rgS$-n?ld24t ttLi36-2116r402594 Ntj(36-?t)54500353 r€56m@!!tm
Membero l th6SGS Group (SGSSAJ
DONGGUAN CITYXINHAI METAL PRODUCTS CO.,LTDfST WEIlrllNG ROAD HENGZENG AV.X|NAN COtiMUNtTY CHANGAN TOWN DONGGUAN ctwGUANGDONG PROVINCE
The following sample(s) wavu/ere submitted and identified on behatf of the dients as : F|SE CAp
T€st Report
SGS Job No. :Composition :Date of S€mple Received :Testing Pedod :Test Requested :
Test lrothod :
Test Results :Condusion :
No. SHAEC1119466002 Date: 13 Oec 2011 Page 'l of4
sP11-03635s - SHNi
02 O€€,201102 oec2011 - 08 Dec 2011Selected test(9 as requested by ctient.Please refer to next page(s).
Please rebr to next page(6).Based on the perfo.med tests on selecled part of submitted sample(s), th€.esults of Lead, Mero.ry, Cadmium, Hexavalent chromium comply with the limitsin RoHS Direclive 201 1/65/EU Annex ; recasting 2002/95/EC.
Signed for and on behalfofscs-csTc Ltd.
/Qv""'Fan Jingjie, JJApproved Signatory
rh'r dsd b 6d b' h on@ Ebhd b n orh crnaud. or !.fun,!! n4b !!q!'d hn d.ffi |dMr D.rh$r r k s.oinrB .{dn.nrhi| Iffi'6 ti-r6i.FEen dD. $rrks.oinrila.{dn.nrhi..ed6 li-n6i.66cd,.l
.d nr.e i.d erH ffi ^4hkr.rdrd@rdbdtdNffiFE;iid.i.i6EEu.ca.r. n{ir .rhnmd, rry. rn.c!|urt.l. do.rbrtr r.6|bcndbdrl\r.dMrdtr h.tEn E, rrv. rn c!|url .l. do.rbrrr r.6rb
!'Ard{btsr|u&.dttuFr{$t9i0ft 2(m3ft .t| .SirAAtlt3e+3+|l lt a@
tEE@{1)0t@50 i€l€(6-a[4a5oda m.ci.4..cMHL{S-A)6140,59. tc{H,)6a50@ ..r.-d'neq,6
Manbor or rh€ SOS Goup (SGS SAt
Te€t Report No. SHAECl119466002 Oate: '13 Dec2011 Page 2 of 4
Test Results :
Test Part Descdolion :
Sp€dn€nNo. SGSSemptetD Dssqipdon1 SHAI t_194660.002 Sitver metat ptating part
Rema*6 :
(1) 1 mgftg= 1 ppm=0.0001%(2) |VDL = tvethod Deteclion Limit(3) ND = Not Detect€d ( < MDL )(4) "-' = Not Regulated
RoHS Dl€ dva ZXIZ95/EC
Test llrgthod: IEC 62321:2008 appticatjon of modified digestion by surtace elching for Cadmrum, Leact ahdl4erorry, anatysis by tCp-OESWth reference to IEC 6232i:2OOB for Hexavalent Chrcmium by spot test / Coto.imetric l\rethod.
Tesl ltem(s)Lead (Pb)Cadmium (Cd)Mercury (Hg)Hexaval€nt Chromium (C l)
Notes :
!r!!l! Ud! lrpl 0e1,000 mg/kg 10 ND100 mdkg 10 ND
1,000 mg/kg 10 NDC Negative
(1) The maximum pemissible timit is quoted from directive 201.1/6tEU, Annex ll(2) o spot-test:Negative = Absence of CrVl coating, Positive = pres€nce of CrVl coating;The tested sample should be further verifed by boiling-wateFexiraction method if the spot test result isNegative or cannot b€ confimed.o Boiling-water-gxtraction:Negalive = Absenc€ of CrVl coatingi Positive = Presence of CrVl coatingThe detected concentration in boiling-waleFextraclion solution is equal or greater than 0.02 mg/kg with 50cm2 sample surface arca.
rhlddnd r. ed 6v rh. c.ntsry &qd b h o,E c6idbr.r 3
Htrffi ,ffi Hl1ff [.T:;f.:H;#f gHi.Y-"#]:,r1Tr:i:,ffi iHffi ,!ff iffi ,::i:it:H;#3*Iil".y""#i,rff rt;:,tHffi Hg*##-*$*p*.-mTH"gJ..i*lH,FlEnbn!!d{!l6. hhrdtut rsF!.r. rE. n.c!ley!.r. dfl$ r r.bti,o
.rrri h tull.dd'od rrr{rnr..9ra.r or!L c.nr.',.. tub.i drd d sr rG
rrcrhrm!rh)rnh
raf Erbell$&d&it dt1gi{fl oir [email protected],Eat l8ca!3tt tt 2o@1
l€lEiS.?tl6lalr!$ lAE6a1t61€St! ff6,!r.MHL(e-?l614gC{ rt {S-?J&€adts . |9r!th&r@
Momb€. or rhs 8os Gloup (gcs srl
Test ReportATTACHMENTS
No. SHAEC1 '1 1 9466002 Oate: 1 3 Dec 201 1 Page 3 of 4
1) Name of lhe person2) Name of lhe per€on
Plating Pb/Cd/Hg/Cf Testing Ftow Chart
who madetesting: Yoyo Wang/Allen Xiaoin charge of testing: Jetf Zh€ng/Geo.ge Xu
Acid washing ofplating layer
Metallic mate.ial
Precisely weighings€mple after acid
wasntng
Adding 1,$diph€nylcarbaz ide for
color developmgnt
A red color indicatesthe pres€nce of Cfl.lf ne@ssary, confirm
,trrhontsnrrlldbn odsrcddlBr.r Ld.. Ddd6 &d.thd tub.rqc b im. nn fr$ €itrr,m.{andrhF. d-q.5inh ltaaEiEnn c,b im. d ffi e rhd;{r D.*r! d * Et 6d,m .{andrhF. r&dim ra afi-6i-F!.d.i' ;d |ldrldo r.sd.nnd l'.di, ^Di.e.f !.lrb lbeist h did M!6h0.r .dcr.dr llFrEd.d, B. lh.6@rr ,b d$tati
h@o-sffid!si,^qi.e. d6 Rdmd r'.i$ drtr r. cft6. lh.cllmv. * fl H$ft r@6cndscr{.cemr.*idmri.-dbrhnrqq
hdd...[mundt!ll.{dlm40r,hlrrdtfrsi.i0rqdirr .tolnidords.r,
rrbhrhrr.L)r.rrd
tbnit5sllri..d&nlrv.tlrlrchi. z(EgFl,-Lt.liEEttl889{r3t, 3t ?M
IE!€(&-2)61.G63 rEl€6{ll6{Str ws.rslmH!(l&?tt1{@0a r{.&-aFsl .t$.d"EO.a.m
MehD€r ol ln6 scs Grdp (sos sA)
Test Report No. SHAECl119466002 Date: '13 Dec 2011 Page 4 of 4
Sample photo:
sHA11-194660.002
SGS authenticate the photo on odginal report onlyt" End of Report *,*
ry e.jM b ir c.roDr cord{,oc o'srcri ..c,un6r h'ii. abd'oii 3 dnm 10-6r idr,o" d,dilrffiR<E,!{'.ddo.,@oidlirod'h!rn^rm.!'qa'r!G"!;.'{;;e;h;riiii i,ffi.;;.;' ja;;;o.conprr,,!dllrtu crbi i@ord![n!d rh'orn ^
J.nd o-..do,. .., e orr.aisdroh! rn.,.-cdd 'h..,,
: J"otElbt8gls\dR.adxlitrioiiljd,sliddEcitu
t tti . etxEr Lir !!99_+1!p Jll?sl]3 rElE186-2r)61.r02553 rElE(86-21)64953t/9 Mcn6qs.dm2M3 H!(86+!)614025S4 NL(36-?1)5,r500053 .sqidna&{sm
MemberofthesGsGrouo lsGssA)
Test Report No. CANEC1207912202 Date:26 Jun 2012 Page 1 of 5
XIAMEN LICHUN ELECTRONIC ELEMENT CO.,LTD
42 2XINGLIN WEST RD.,361O22,JIMEI DISTRICT,XIA['EN,,FUJIAN,P.R.C
Test Results :
Conclusion :
The following s€mple(s) was^/vere submitted and identified on behalf of the clients as : BOSI GLASS TUBE
SGS Job No. : XM13901119EC-XM
Date of Sample Received : 18 Jun 2012
Testing Period : 18 Jun 2012 '26 Jun 2012
Test Requested : Selected test(s) as requested by client.
Test Method : Please fefer to next page(s)
Please refer to next page(s).
Based on the oeformed tests on submitted samples, the results of Lead,Mercury, Cadmium. Hexavalent chromium, Polybrominated biphenyls (PBB),
Polybrominated diphenyl ethers (PBDE) comply with the limits as s€t by RoHSDireclive 2011/65/EU Annex ll; recasting 2002/95/EC.
Signed for and on behalf ofscs-csrc Ltd.
Luc'y WuApproved Signatory
ii:trii";df#i*iil:i":#i'Tiiiqili'",'iq;l[i+ill$]*Ji":ia"#r.:ilr.'""?ir"'i1i':"'"#-
1g(drRods&$rdorgn Edu{t1drlUDtd(FlilkEoldogtu 510€63
+q.r'rijSt&^4t8fl*dfl6gls3€ i!fr:s10663r 66-201s2r56666 ' 136-20 e07t 13r is6xre,5s5s5 r €6-20)s2o75us e 3$sd1*e4tm
Momb€.ollhdscs GrouP {scs sA)
Test Report No. CANEC1207912202 oate:26 Jun 2012 Page 2 of5
Test Results :
Test Part Descriotion :
Spodmen No. SGS Sample lD O€6cfiption1 CAN12-079122.002 Transparent glass tube
Remarks :(1) 1 mg/kg = 1 PPm = 0 0001%
(2) MDL = Method Detection Limit
(3) ND = Not Detected ( < l\rDL )(4) "-" = Not Regulated
RoHS Dlr€div6 2()l 1/85/EU
Test Method : with reference to lEc 62321:2008(1) Detemination ofCadmium by ICP-OES.(2) Determination of Lead by ICP-OES(3) Determination of lrerdiry by ICP-OES.(4) Determination of Hexavalent Chromium by Colorimetdc Method using lJV_Vis'
(5) Determination of PBBS / PBDES content by GC-MS
Test ltem{s)C.dmium (Cd)Lead (Pb)
[,lercury (Hg)
Hexavalent Chromium (crvl)
Sum of PBBSMonobromobiphenylDibromobiphenylTribromobiphenylTetrabromobiPhenylPentabromobiPhenylHexabromobiphenylHeptabromobiphenylOctabromobiphenylNonabromobiphenylDecabromobiphenylSum of PBDESMonobromodiphenyl ether
Limit Unit MDL
100 mS/kS 2
1.000 mg/kg 2
1,000 mg/kg 2
1,000 mg/kg 2
1,000 mg/kg- mdkg 5, mg/kg 5- mdkS 5- mg/kg 5- mg/kg 5- mo/kg 5- mg/kg 5- ms/kg 5- msiks 5- mg/lq 5
1,000 mg/kg- mdkg 5
'Sield&rrdrrituttbt@rln{qtc.@d0dotdsotu 510663
F!.Ttir'F8fii*&4fl+ffl**1$q 8r:5i0663
9uNDN DNDN DNDNDNDNDNDNDNDNDNDNDNDNDND
r i!5-08a56656 I l!6_20)32075113 Mc03{tl.n
l is-Oe156s6 1(!F20)3207s113 ' {sch*€is3s
Memb€rorlh€ scs Gmw {sossA}
illi:tr1y:lr:i;i:1":'"sf;:H:l'1i5$i{,ff;1ti!.'di$:::fiirtriii,i"s.ii:'#ii#;*,r#S{s.,#lU-"tii}HilffiiltliFtldlffi"{;;tu'i d-k-.;ehd6.,"h.
Test Report
Test ltem(sl
Dibrcmodiphenyl elhet
Tribromodiphenyl ether
Tetrabromodiphenyl ether
Pentabromodiphenyl ether
Hexabromodiphenyl ether
Heptabromodiphenyl ethe.
Octabromodiphenyl etherNonabromodiphenyl ethetDecabromodiphenyl ether
Notes :
No. CANEC1207912202 Date: 26 Jun 2012 Page 3 ol 5
:q ̂ nftd soFE Prrcdd! tow tqrotT t'0dloJgslm 51m6J
4@ .r ,l1 .&fitl^f&D 6e!i! e&l$e ar' )'r$63
0!2NDNDNDNDNDNDNDNDND
j lS6 rrel$666 | 136_&)3?0751i3r (86 20) s2r555s5 r lS6-2OlS2O7t'3 e s€s dB@'3ss M
Menbe 'or lho SGs GrouP (sGS SA)
t!d! ui!mgKgmg/Kgmg/Kgmg/KgmgKgmg/Kgmg/Kgmg/Kgmg/Kg
IVDL
555555555
(1) The maximum permissible limit is quoted ftom the directive 2011/65/EU, Annex ll
i
Test Report No. CANEC1207912202 Date: 26 Jun 2012 Page 4 of 5
ATTACHMENTSRoHS Testing FlowChart
'1 ) Name of the peEon who made testing: Bella Wang / Cutey Yu2) Name of the person in charge of testing: Adams Yu / Ryan Yang3lThese samolis were dissolved tcElly by pre-conditioning method according to below flow chart'(Cf*
and PBBS/PBDES test method excluded).
ifu i.,!;"#Isi.:11*fiifi ';2l':l-:i,:lil"'li"rX=r*fr jip;;rs.#*i*t$1g$]lt$#ffi*$;'#f$$ili'l$liryh]ii:ffit*rtr*:i::i;i"r"*:?ril?!?:li:ni3*:*"
,0qcdbdprolss''*rkddq0,.r'li0.dci*Eo* r(863,ffi;:;ffi I ffi:trl,i " JX$T:sE.r- i t l .E t ,GtreEsgt iF&* la3t 6t :51
Pbrcd/Hg PBB3/PBDE8
Positive
Acid digestion withmicrcwaveJ hotplate
1) Alkali Fusion /Dry Ashing
2) Acid todissolve
Adding 1,tdiphenylcarbazidefor colordevelopment
Adding 1,5-diphenylcarbazidefor colordevelopment
A red colorindicates thepresence of CF*.f necessary,confirm with
M6mberollho sGS GrouP (SGs sA)
SGSTest Report
Sample photo:
cAN12-079122.002
SGS authenticate the photo on onginal report only
'** End of Report *-
;H:S:,I"t'*i;H'"ltT:-l::.t:,':ffi:'.-.#i":._a.r-li!;i;1".j;:r*,T::Xt;:,ru1rw,*ir.!:iitii:i,-Si,'lit1{.i:iiT:iq',iT#ilii:i::iij"::'j,*'rfl'#rffliilrl-":ll;r,lrurii:**'"r
1106-,0)&155696 I {3H0)320751r3 Mm 59rM
I (st-!o)s?155556 l 1s6-2o)s20751ls' ssscrrna€F$M
No. CANEC1207912202 Datet 26 Jun 2012 Page 5 of 5
rlt{0r! R6l5edlP'l(slr{dnEdni&di@06!hFstod'{otgaroi! 510663
+!l' et&**AE*+r*i+$*re3S 4n:s1m63MeFborolrhe SGs6DuP (SGSSA)
TIANJIN BAIRUIJIE WELDING IJATERIAL CO.,LTD.
NO.38,BAOYUAN ROAD,EAST ZONE OF JINNAN DEVELPOPMENT ZONE,JINNAN DISTRICT,TIANJINCHINA
The following sample(s) was^/vere submitted and identified on behatf of the clients as : TIN-COATED COppERWIRE
Test Report
SGS Job No. :
Composition :Date ofSampl€ Received :Testing Period :
Test Requested :
Test Method :
Test Resulb :
Conclusion :
No. TSNEC1110357903 Date: 26 Oct 2011 Page 1of 5
TP1 1-0021 84 - TJCu
210d2011
21ocl2011 -26 ccl2011Selected test(s) as requested by client.
Please refer to next page(s).
Please refer to next page(s).
Based on the performed tests on submitted samples, the results of Lead,I\rercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (pBB),Polybrominated diphenyl ethe6 (PBDE) compty with the limits as set by RoHSDirective 2011l65/EtJ Annex ll; recasting 2002/95/EC.
scsM3B6,No..t,Yh.5n a-^J.rEDA.n.f i ch'E 3m457 r (e-z4ed8am
Signed for and on behalf ofscs-csTc Ltd.
;@-Reabeca ZhouApproved Signatory
]|beua|' ' ] l id!yli. ku. m qEr or rr.dd. i in! /fowr.F.e4n q!-Ln._!,!!!rtgr!'u.!!!E qq!&!!!!_dee!!!!Li!i ^
$.rrnrotdrdr i6ro.1rodr, rt!i,. id olrb.doi. l ier rh. r. isdioi d
rbdi iriLrn.tsnor.rdiyroh.rmehlr)rftd
I @-425295?t? *w.6 43.comr (86-?425aS2 s 5$r .b€!F.M+t.ttiiE lti*tAfEit4rBscsi! lll: 300457 r 136-2a6s2t{0oo
M6nb€rorrhoscs couD {sos sA)
Test Report No. TSNEC1110357903 Date: 26 oct 2011 Page 2 of 5
Test Resulb :
Test Pad Descriotion :
Spodmen No. SGS Samde lD D6.*iptbnI TSN1 l -103579.002 sjtvery metatwire
Remal}6 :
(1) I mgftg= l PPm=0.0001%(2) MDL = lrethod Detedion Limit(3) ND = Not Detecled ( < MDL )(4)'-" = Not Regulated
RoHSI DllEdive 201 I,/8AEU
Test llethod : With reference to IEC 6232't:2008(1) Determination of Cadmium by tCp-OES.(2) Detemination of Lead by |CP-OES.(3) Determination of [,lefcury by tCp-OES.(4) Detemination of Hexavalent Chromium by Spot test / Colorimetric Method using UV-Vis.(5) Determination of PBBS / pBDEs by GC-MS.
Test ltem(s)
Cadmium (Cd)Lead (Pb)lllercury (Hg)Hexavalent Chromium (C(Vl))
MonobromobiphenylDibromobiphenylTribromobiphenylTetrabromobiphenylPentabromobiphenyl
HeptabromobiphenylOctabromobiphenylNonabromobiphenylDecabromobiphenylSum of PBOESMonobromodiphenyl ether
tjDj! Unit
10O mS/Kg1,000 ms/Ks1,000 mg/kg
1,000 mg/kg- mg/Kg- mg/Kg- mg/Kg_ mg/xg- mg/(g- ms/Kg- mg/Kg- mgks- mdks- mgKg
1,000 msu4a- mgKg
sc3lLdlon,l{orl,Tn $r alcuTEoAThnltn,chtB 3&atfl.tlrilttitllflt*tlrrts€s*! ttr3o$r
r (s.22t6623gm r 1&24A4562| (e2a62sd l(*-?a5@ . .6jir'.OF@
MDt @2 N D2 N D2 N DC Negative
ND5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D5 N D- N D
5 N D
lo.d [email protected] b r.m d I tri,_rr!!,colrr!.'nt .,!ecu!rt!!1!!!i. diiii& ii ddni b-i'.lFnria.|d ttd Fehi i.d fiMr$hrnt hcdr 0rhr dsm.d r dndfiMii-h.rnt hcdr 0thr dsm.d t dnd h.l
tuhro'csrr 'iffia tmr .eal;l. Fd*-b. dBr,.-. d o d i g d b i . q d i 0 r f u n 6 @ ! . . d . 1 4 p | h | u l ' { b d D d . ' - h | i
rhoi ri si h rrd *r onrr ro rtu t6ph(.'r.rbd .
M€nb6' or rh6 scs o,o!p (sos sAj
Test ReportTesl ltem(s)
Dibromodiphenyl olherTdbromodiphenyt elherTetrabromodiphenyl etherPenlabromodiphenyl etherHexabromodiphenyl elherHeptabromodiphenyl ethe.Oclabromodiphenyl etherNonabromodiphenyl etherDecabromodjphenyl ether
Notes :
No. TSNEC1110357903 DaIe: 26 Od 2O11 Page 3 of 5
ti!r! UlImg/rgms/kgms/k9mgKsmgKgmg/rgmgftgmg/Kgmg/Kg
MDL
555555555
peNDN DNDNDNDNON DN DND
(1) The maximum permissible timit is quoted from directive 2011/65/ElJ. Annex .(2) o spot-test:Negative = Absence ofCr(Vl) coating, positive = presence ofC(Vt) coating;The tested sample should be further verified by boiling-wEter-€xtraction method ifthe spot test resutt asNegative or c€nnot be confimed,o Boiling-wateFextraction:Negative = Absence of Cr(Vl) coaling; positive = presence of C(Vt) coatingThe detecled concentration in boiling-watef-extraction solution is equalor greater than 0.02 mg/kg with 50cm2 sample surface area.For conosion protection coatings on metals: Information on stofage conditions and production date ofthetested sample is unavailable and thus results of Cr(VI) represent status of the sampte at the time oftesting
riLdc!d!i.,tdb'h.ffi b ffira hffir a u*:!llg4lrd r!4!e! h!!! ^dldbi tr di.
lq..dhrb' !.u. d..d rM^ &yMtoroi'r!Frrbtt. i |4ai
r 06-4252$52{ (s-4 25e95252
Memb.ror th.SGSG@rISOSSAl
Test Report
ATTASHMENTS
'l) Name2) Name3) Thsse(Cf* end
cdpb/t{g/cl./FBBs&pBDEr Tcsdng Ftow c-h.It
oflh6 porcon who mads tesiing: Aaron Wang/Jeson Li/Angell yeoofthe psrson in charge oftesting: Cindy yin,/Rsx Zhusamplss wer8 dissolved iotel ly by prs-condil ionjng method according to bslow f low chadPBBs/PBDEs iesl rnethod excluded)
I scs u.nrio,r{orar.Th. 5|| Avru1ED4Tt rth,chkE sas, I {a_2216*w I F,r?r5295252| +!::!$'et!11!g!Ili41!!9!*! !!i9erl |p&.e!ry r(!:a,5ry9
Page 4 of 5No. TSNEC1110357903 Date:26 Oct 2011
Sample Preparation
Sample lVeasurBmeil
Acid digeBlion w'thmicrc,,rave/ hotplale
Sample solv€ntextraclion
ConcenlraliorVDilution ofexlraciion
s0lution
1)Alkali Fusion /0ry Ashing2) Acid todissolve
Boil ing waterBxllacl,on
Adding 1 ,5-diphenylcarbazid€ for
color d9velopmenl
Ared color indicalgsthe presence ofCre.lf necessary, conlifm
N€gative
_{ dlld ll .d by b. 6@y &q.o 'o in c.tu.' cod 16. d e
rbc.iF.ri sh '6pdMn bb ,{6s.jbrhirqqcunxbrN'6ed.|dbryd!
[{olnb.rot rhs SGS GrolD (SOS SA)
Test Report
Sample photo:
I :9sl!j.atY11nE 5rr ̂ nu.rEoard4,n chtm 300.s7 , c4fiasqD trar46eereI
sr. tttI*IlErI*3r+scsrit tt fi.57 r {S_?2t662mr @r?2sa5a?
No. TSNEC1110357903 Date: 26 oct 2011 Page 5 of 5
TSN11-103579.002
SGS authentic€tethe photo on original reporl only'" End of Report -.
rh*ni.'c,st n,nei. r."r mom-rr,;i,iipi;in'; i;;;;;fi;i; ;;l :;"TiLr#;ltril#l1tr"lii?:l::1Yi:-1ltPl!"'' '."d"i.dh...b,'q.."i;b;d.i;;;;i;.i;
.r lfr i i ! l l . l !1'pn..i.|c']ylo6.[n'1.{r|hfi
rr.flb.r ol th. ScS O|o!p (SOS SAI