Icom IC-207H Instruction Manual

download Icom IC-207H Instruction Manual

of 80

Transcript of Icom IC-207H Instruction Manual

  • 8/8/2019 Icom IC-207H Instruction Manual

    1/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    2/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    3/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    4/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    5/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    6/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    7/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    8/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    9/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    10/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    11/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    12/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    13/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    14/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    15/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    16/80

  • 8/8/2019 Icom IC-207H Instruction Manual

    17/80

    2INSTALLATION

    12

    I Optional MB-58 installation

    The optional MB-58 REMOTE CONTROLLER BRACKET is avail-able for separate installation.

    Drill 2 or 4 holes where the bracket or mounting base is tobe installed, respectively. Approx. 4 mm ( 1 8 in) when using nuts; approx. 1 2 mm ( 1 16 in)

    when using self-tapping screws. Insert the supplied screws, bolts and washers through the

    mounting base and tighten. Adjust the angle for the clearest view of the function dis-

    play and tighten 2 screws when the mounting base is used.

    BracketWhen using self-tapping screws.

    Mountingbase

    Mountingbolt

    Attach the supplied Velcro pads (large) to the remote con-troller and bracket. Attach the supplied Velcro pad (small) or rubber pad to the

    bracket as shown below; then attach the remote controller.

    D When using the MB-65

    MB-58 IC-207H remote controller

    MB-58

    MB-65

    Adjust the viewingangle for maximumvisibility of the func-tion display.

  • 8/8/2019 Icom IC-207H Instruction Manual

    18/80

    2 INSTALLATION

    13

    I Battery connection I DC power supply connection

    Use a 13.8 V DC power supply with more than 12 A capabil-ity. An optional IC-PS30 DC POWER SUPPLY is available forusing the transceiver with a DC power supply in your home.

    Make sure the ground terminal of the DC power supply isgrounded.

    NEVER connect the transceiver directly to a 24 V battery.DO NOT use the cigarette lighter socket for power con-nections.Attach a rubber grommet when passing the DC powercable through a metal plate to prevent short circuits.

    CONNECTING TO A DC POWER SOURCESee p. 69 for fuse replacement.

    Fuses20 A

    blackred

    red

    Grommet

    black

    12 VSuppliedDC power cable

    CONNECTING TO A DC POWER SUPPLYSee p.69 for fuse replacement.

    DC powersupply 13.8 V

    to anACoutlet

    Fuses20 Ablack

    red

  • 8/8/2019 Icom IC-207H Instruction Manual

    19/80

    2INSTALLATION

    14

    I Antenna installation

    D Antenna locationTo obtain maximum performance from the transceiver, selecta high-quality antenna and mount it in a good location. A non-radial antenna should be used when using a magnetic mount.

    D Antenna splitterYou can use a dual band antenna because a duplexer is in-stalled in the transceiver. However, an external duplexer mustbe connected when using a separate antenna for each band.

    D Antenna connectorThe antenna uses a PL-259 connector.

    30 mm

    10 mm (soft solder)

    10 mm

    12 mm

    solder solder

    Softsolder

    Coupling ring

    PL-259 CONNECTOR

    Slide the coupling ringdown. Strip the cable

    jacket and soft solder.

    Slide the connectorbody on and solder it.

    Screw the couplingring onto the connec-tor body.

    Strip the cable asshown at right. Softsolder the center con-ductor.

    (10 mm 3 8 in)

    Roof-mount antenna(Drill a hole or use a magnetic mount.)

    Gutter-mount antenna

    Trunk-mountantenna

  • 8/8/2019 Icom IC-207H Instruction Manual

    20/80

    SETTING A FREQUENCY3

    15

    I Preparation

    D Turning power ON/OFFPush [PWR] for 1 sec. to turn power ON or OFF.

    D Operating bandThe IC-207H can receive/transmit on the 144 MHz and430(440) MHz bands, or receive only on the avionics band(USA version only).

    Push [BAND] one or more times to select the desired operat-ing band. The frequency changes to indicate the selected band. The operating band cannot be changed unless you are in VFO

    mode (see right).

    Push [BAND] one or more times to select the de-sired operating band.

    D VFO and memory modesThe transceiver has 2 normal operating modes: VFO modeand memory mode.

    Push [V/MHz] to select VFO mode when the transceiver isnot in VFO mode. If VFO mode is already selected, the digits below 100 kHz disap-

    pear. In this case, push [V/MHz] again (or push twice depending onversion).

    Push [VFO] to select VFO mode.

    Push [PWR] for 1 sec.

    BAND

    Appears when memory modeis selected.

    VFO mode is selected.

    HI 1 95 HI 1 95

    VFO

  • 8/8/2019 Icom IC-207H Instruction Manual

    21/80

    3SETTING A FREQUENCY

    16

    I Lock functions

    To prevent accidental frequency changes and unnecessaryfunction access, use the lock function. The transceiver has 2different lock functions.

    D Frequency lock This function locks the tuning dial and switches electronicallyand can be used together with the microphone lock function.

    Push and hold until L appears in the memory chan-nel readout to activate the function. To cancel the function, push and hold until L disappears. [PTT], [MONI], [VOL] and [SQL] can be used while the frequency

    lock function is in use. Also, TONE-1, TONE-2, DTMF tones orDTMF memory contents can be transmitted from the microphone.

    Push and hold [ (VFO) LOCK] for 1 sec. to togglethe function ON and OFF.

    LOCK

    LOCK

    D Microphone keypad lock This function locks the microphone keypad.

    Push [FUNC] then [ A 16 KEYLOCK] to togglethe microphone keypad lock function ON andOFF. [PTT] and the 7 keys on the upper half of the mi-

    crophone can be used. All switches on the transceiver can be used. The keypad lock function is released when the

    power is turned OFF then ON again.

    L appears while the frequencylock function is in use.

    HI 1 95

    LOCK

    16 KEY LOCK#

  • 8/8/2019 Icom IC-207H Instruction Manual

    22/80

    3 SETTING A FREQUENCY

    17

    I Using the tuning dial

    Push [BAND] to select the desired band, if necessary. Rotate the tuning dial to set the frequency.

    If VFO mode is not selected, push the [V/MHz] to select VFOmode.

    Frequency changes according to the selected tuning steps.(p. 18)

    For the 1 MHz frequency setting, rotate the tuning dial afterpushing [V/MHz]. Pushing [V/MHz] for 1 sec. starts a scan function. If this happens,

    push [V/MHz] again to stop the scan.

    I Using [ Y ]/[Z ] switches

    Push [ Y ] or [ Z ] to set the selected band s fre-quency. If VFO mode is not selected, push [VFO] to select it. Frequency changes according to the selected tuning

    steps. (p. 18) Pushing [ Y ] or [Z ] for more than 0.5 sec. activates a

    scan. If this happens, push [ Y ] or [Z ] again to stop it.

    NOTE: 1 MHz steps cannot be used via the [ Y ]/[Z ]switches.

    The display shows that the 1 MHztuning step is selected for theVHF band.

    HI 1 95

    YZ

  • 8/8/2019 Icom IC-207H Instruction Manual

    23/80

    3SETTING A FREQUENCY

    18

    I Tuning step selection

    Tuning steps are the minimum frequency change incrementswhen you rotate the tuning dial or push the [ Y ] or [Z ]switches on the microphone. The following tuning steps areavailable:

    5 kHz 10 kHz 12.5 kHz 15 kHz 20 kHz 25 kHz 30 kHz 50 kHz

    NOTE: For convenience, select a tuning step thatmatches the frequency intervals of repeaters in your area.

    Push [BAND] to select the desired band, if necessary. Push [V/MHz] to select VFO mode if another mode has

    been selected. Push [SET] one or more times until tS appears as shown

    below. Pushing [MONI] reverses the order of selection. Cancel the DTMF memory function in advance. (p. 48)

    Rotate the tuning dial to select the tuning step.

    Push [V/MHz] to exit set mode.

    Push [BAND] to select the operating band, ifnecessary.

    Push [VFO] to select VFO mode. Push [ F SET] one or more times until tS ap-pears as shown previously. Push [ENT] to reverse the order of selection. Cancel the DTMF memory function in advance.

    (p. 48) Push [ Y ] or [Z ] to select the tuning step. Push [CLR] to exit set mode.

    USING SET MODE

    25 kHz tuning step15 kHz tuning step

    HI 1 95 HI 1 95

    SETB

  • 8/8/2019 Icom IC-207H Instruction Manual

    24/80

    3 SETTING A FREQUENCY

    19

    I Using the keypad

    The frequency can be directly set via numeralkeys on the microphone.

    Push [BAND] to set the operating band, if necessary. Push [VFO] to select VFO mode. Push [ENT] to activate the keypad for digit input.

    Push 5 keys to input a frequency. When a digit is mistakenly input, push [ENT] to clear the input,

    then input from the 1st digit. Pushing [CLR] clears input digits and retrieves the frequency.

    Push [ Y ] or [Z ] to make adjustments below the 10 kHzdigit, if desired.

    [EXAMPLE]: Setting the frequency to 145.360 MHz.

    [EXAMPLE]: Setting the frequency to 446.325 MHz. (When the 25 kHz tuning step is selected in UHF.)

    BAND then VFO CENT 3PRIO5MID1MONI 4HIGH 6LOW

    195 1

    95 195 1

    95

    195 1

    95 195 1

    95 195

    BAND then VFO CENT 3PRIO6LOW4HIGH 4HIGH 0VOL

    ENTC

  • 8/8/2019 Icom IC-207H Instruction Manual

    25/80

    BASIC OPERATION 4

    2

    I Receiving

    Push [PWR] for 1 sec. to turn power ON. Push [BAND] to select a band. Set the audio level. Push [MONI] to open the squelch. Rotate the [VOL] control to adjust the audio output level. Push [MONI] again to close the squelch.

    Set the squelch level. Rotate [SQL] fully counterclockwise in advance. Rotate [SQL] clockwise until the noise just disappears.

    When interference is received, rotate [SQL] clockwiseagain for attenuator operation.

    Set the operating frequency. (pgs. 15 19) When receiving a signal on the set frequency, squelch

    opens and the transceiver emits audio. BUSY appears and the S/RF indicator shows the relative signal

    strength for a received signal.

    When receiving a signal on VHF.

    BUSYHI 1

    95

    The volume and squelch levels can be adjusted via the mi-crophone. However, levels return to the front panel settingwhen power is turned OFF or a front panel control is adjusted.

    Push [PWR] on the transceiver for 1 sec. to turnpower ON.

    Set the audio levels. Select the desired band. Push [ MONI], then push [ BZ VOL] or

    [IY VOL] to adjust the audio level. Push [ MONI] again to close the squelch.

    Set the squelch level using [ AZ SQL] or[HY SQL], if desired.

    Set the operating frequency. (pgs. 15 19)

    CONVENIENT

    RF attenuator: The transceiver has an RF attenuator relatedto the [SQL] setting. The attenuator is automatically activatedwhen [SQL] is rotated further than the 12 o clock position.Approx. 10 dB attenuation is obtained at full rotation.

    Appears while setting volume Appears while setting squelch

    BUSYHI 1 95 HI 1

    95

    BAND

    VOL

    VOL

  • 8/8/2019 Icom IC-207H Instruction Manual

    26/80

    4 BASIC OPERATION

    21

    I Avionics band receive (U.S.A. version only)

    AM mode can be selected over the range of 118.000 to135.995 MHz for reception of avionics-related broadcasts.

    Push [BAND] one or more times to select the aviationband.

    Push and hold [BAND] to toggle between AM and FMmodes. Mode selection cannot be performed via the microphone.

    CONVENIENT The tuning steps for the avionics band are available sepa-rately from those for other ranges.

    Appears when AM mode is selected.

    HI 1 95

    I Monitor function

    This function is used to listen to weak signals without disturb-ing the squelch setting or to open the operating band ssquelch manually even when mute functions such as tonesquelch are in use.

    Push [MONI] to open the operating band s squelch. Push [MONI] again to cancel the function. While duplex is ON for repeater operation, the transmitting fre-

    quency can be monitored with [MONI].

    Push [BAND] to change bands, if necessary. Push [ MONI] to open the operating band s

    squelch. Push [ MONI] again to cancel the function.

    I Audio mute functionThis function mutes the operating band s audiowithout disturbing the volume setting.

    Push [FUNC] then [ H MUTE] to mute the operating band saudio signals MUTE appears.

    Push [ E CLR] (or any other key) to cancel the function. MUTE disappears.

    MONI

    MUTEH

  • 8/8/2019 Icom IC-207H Instruction Manual

    27/80

    4BASIC OPERATION

    22

    I Transmitting

    CAUTION: Transmitting without an antenna may dam-age the transceiver.

    NOTE: To prevent interference, listen on the frequency be-fore transmitting by pushing [MONI] or [ MONI] on the mi-crophone.

    Push [BAND] one or more times to select the operatingband.

    Set the operating frequency. (pgs. 15 19) Select output power if desired. See section at right for details.

    Push and hold [PTT] to transmit. $ appears. The S/RF indicator shows the output power selection. The operating frequency, etc. are automatically programmed into

    a scratch pad memory. See p. 36 for details. One-touch PTT function is available. See p. 23 for details.

    Speak into the microphone using your normal voice level. DO NOT hold the microphone too close to your mouth or speak

    too loudly. This may distort the signal. Release [PTT] to return to receive.

    I Selecting the output power

    The transceiver has 4 output power levels to suit your oper-ating requirements. Low output powers during short-distancecommunications may reduce the possibility of interference toother stations and will reduce current consumption.

    Push [BAND] one or more times to select the operatingband.

    Push [LOW] one or more times to select the desired out-put power. The output power can be changed while transmitting.

    POWERSELECTION S/RF INDICATOR VHF UHF

    HI 50 W 35 W

    MID-HI 20 W 20 W

    MID-LO 10 W 10 W

    LO 5 W 5 W

    195

    195

    195

    1

    95

  • 8/8/2019 Icom IC-207H Instruction Manual

    28/80

    4 BASIC OPERATION

    23

    The microphone can select the desired outputpower directly.

    Push [BAND] to select the desired band, if nec-essary.

    Push [ HIGH] for high output power; [ MID] formid-high output power; [ LOW] for low outputpower.

    MID-LO output power CANNOT be selected viathese microphone keys, however, the default settingfor [F-1] is output power selection MID-LO outputpower CAN be selected using [F-1], in this case.

    The output power CANNOT be changed via the mi-crophone while transmitting.

    I One-touch PTT function

    The PTT switch can be operated as a one-touchPTT switch (each push toggles transmit/receive).Using this function, you can transmit without push-ing and holding the PTT switch.

    To prevent accidental, continuous transmissionswith the one-touch PTT function, the transceiverhas a time-out timer. See p. 59 for details.

    Push [FUNC] then [ PTT-M] to turn the one-touch PTTfunction ON. The activity indicator lights green.

    Push [PTT] to transmit and push again to receive. Two beeps sound when transmission is started and a long beep

    sounds when returning to receive. $ ashes while transmitting with the one-touch PTT func-

    tion. Push [FUNC] then [ PTT-M] to turn the one-touch PTT

    function OFF. The activity indicator goes out.

    HIGH4

    MID5

    LOW6

    PTT-M3

  • 8/8/2019 Icom IC-207H Instruction Manual

    29/80

    REPEATER OPERATION 5

    2

    I Accessing a repeater

    Push [BAND] one or more times to select the desired band. Set the receive frequency (repeater output frequency).(pgs. 15 19)

    Push and hold for 1 sec., one or more times, to se-lect duplex or + duplex. DUP or DUP appears to indicate the transmit frequency for

    minus shift or plus shift, respectively. When the auto repeater function is turned ON, (available for the

    U.S.A. version only), steps , are not necessary. (p. 31)

    Push [TONE] one or more times to turn ON the subaudibletone encoder, according to repeater requirements. Refer to p. 26 for tone frequency settings. When the repeater requires a different tone system, see the page

    at right.

    Push and hold [PTT] to transmit. The displayed frequency automatically changes to the transmit

    frequency (repeater input frequency). The operating condition is automatically programmed into a

    scratch pad memory. See p. 36 for details.

    DUP

    If oFF appears, con rm the offset frequency. (p. 27) Release [PTT] to receive. Push [MONI] to check whether the other station s transmit

    signal can be directly received or not. To return to simplex, push for 1 sec., once or twice,

    to clear the DUP indicator. To turn OFF the subaudible tone encoder, push [TONE]

    one or more times until no tone indicators appear.

    DUP

    DUPHI 1 95T

    DUPHI

    195

    T

  • 8/8/2019 Icom IC-207H Instruction Manual

    30/80

    5 REPEATER OPERATION

    25

    Push [BAND] to select the desired band, if nec-essary.

    Set the receive frequency (repeater output fre-quency). (pgs. 15 19)

    Push [ DUP ] to select duplex; push[DUP+] for + duplex.

    Push [FUNC] then [ TONE] to turn ON thesubaudible tone encoder according to repeaterrequirements. Refer to p. 26 for tone frequency setting. When the repeater requires a different tone system,

    see at right. Push and hold [PTT] to transmit. Push and hold [ MONI] to check whether the

    other station s signal can be directly received. Release [PTT] to receive. To return to simplex operation, push [ SIMP]. To turn OFF the subaudible tone encoder, push

    [FUNC], then [ G T-OFF].

    D DTMF tonesPush [DTMF-S], then push the keys of the desired

    DTMF digits. The function indicator lights green. 09, AD, M(E) and #(F) are available. Cancel the DTMF memory encoder function in ad-

    vance. (p. 48) Push [DTMF-S] again to return the keypad to normal

    function control. The transceiver has 14 DTMF memory channels for

    autopatch operation. See p. 46 for details.

    D 1750 Hz toneA 1750 Hz tone is required to access most European re-peaters. The microphone has 1750 Hz tone capability.

    Push [FUNC]. The mode indicator lights orange.

    Push [ B TONE-1] to transmit a 1750 Hz tonecall signal for 0.5 sec.; push and hold [ I TONE-2] to transmit a 1750 Hz tone call signal for an

    arbitrary period. The mode indicator goes out automatically. The optional HM-90 also has 1750 Hz tone capability.

    TONE-1

    TONE-2

    DUP 7

    DUP+8

    SIMP9

    DTMF S

  • 8/8/2019 Icom IC-207H Instruction Manual

    31/80

    5REPEATER OPERATION

    26

    I Subaudible tones

    Push [BAND] to select the desired band. Select the mode/channel you wish to set the subaudible

    tone frequency to, such as VFO mode or memory/callchannel.

    Push [SET] one or more times until T and rT appearsfor repeater use; or until T SQL and CT appears for tonesquelch or pocket beep use. Push [MONI] to reverse the order of selection. Cancel the DTMF memory encoder function in advance. (p. 48)

    Rotate the tuning dial to select and set the desired fre-quency.

    Push [V/MHz] to exit set mode.

    NOTE: The subaudible tone frequency can be set in amemory channel temporarily. However, the set contentsare cleared once the memory/call mode is selected. Tostore the tone frequency permanently, overwrite the chan-nel information.

    USING SET MODE

    Separate setting for each band

    The display shows that an88.5 Hz subaudible tonefrequency is set for re-peater use.

    THI 1 95

    Push [BAND] to select the desired band, if nec-essary.

    Set the mode/channel you wish to set the sub-audible tone frequency to, such as VFO mode,memory/call channel or scratch pad memory. The subaudible tone frequency is independently pro-

    grammed into each mode or channel. Push [ F SET] one or more times until T and

    rT appears for repeater use; or until T SQL

    and CT appears for tone squelch or pocketbeep use. Pushing [ G ENT] reverses the order of selection. Cancel the DTMF memory encoder function in ad-

    vance. (p. 48) Push [ Y ] or [Z ] to select and set the desired

    frequency. Pushing and holding [ Y ] or [Z ] changes the fre-

    quency continuously. Push [ E CLR] to exit set mode.

    Subaudible tone frequency list (unit: Hz)67.0 79.7 94.8 110.9 131.8 156.7 171.3 186.269.3 82.5 97.4 114.8 136.5 159.8 173.8 189.971.9 85.4 100.0 118.8 141.3 162.2 177.3 192.874.4 88.5 103.5 123.0 146.2 165.5 179.9 196.677.0 91.5 107.2 127.3 151.4 167.9 183.5 199.5

    203.5206.5210.7218.1225.7

    229.1233.6241.8250.3254.1

    SETB

  • 8/8/2019 Icom IC-207H Instruction Manual

    32/80

    5 REPEATER OPERATION

    27

    I Offset frequency

    Push [BAND] to select the desired band. Select the mode/channel you wish to set the offset fre-

    quency to, such as VFO mode or memory/call channel. The offset frequency can be independently programmed into

    each mode or channel. Push [SET] one or more times until DUP appears and

    ashes as shown above. Pushing [MONI] reverses the order of selection. Cancel the DTMF memory encoder in advance. (p. 48)

    Rotate the tuning dial to set the desired frequency. Selectable step increment is the same as the preset tuning step.

    (p. 18) Use [V/MHz] for quick MHz setting.

    Push [V/MHz] to exit set mode.

    USING SET MODE

    Separate setting for each band

    The display shows that a0.6 MHz (600 kHz) fre-quency is set.

    HI 1 95DUP

    Push [BAND] to select the desired band, if nec-essary.

    Set the mode/channel you wish to set the off-set frequency to, such as VFO mode or mem-ory/call channel. The offset frequency can be independently pro-

    grammed into each mode or channel. Push [ F SET] one or more times until DUP ap-

    pears and ashes as shown at left. Pushing [ G ENT] reverses the order of selection. Cancel the DTMF memory encoder in advance.

    (p. 48) Push [ Y ] or [Z ] to select and set the desired

    frequency. Selectable step increment is the same as the preset

    tuning step. (p. 18) Pushing and holding [ Y ] or [Z ] changes the fre-

    quency continuously. Push [ E CLR] to exit set mode.

    NOTE: The offset frequency can be set in a memory chan-nel temporarily. However, the set contents are clearedonce the memory/call mode is selected. To store the offsetfrequency permanently, overwrite the channel information.

    SETB

  • 8/8/2019 Icom IC-207H Instruction Manual

    33/80

    D Frequency range and offset direction

    5REPEATER OPERATION

    28

    I Auto repeater(U.S.A. version only)

    The U.S.A. version automatically activates the repeater set-tings (DUP or DUP and tone encoder ON/OFF) when theoperating frequency falls within the general repeater outputfrequency range and deactivates them when outside of therange.

    D Setting the auto repeater function ON/OFF Push [PWR] to turn power OFF.

    While pushing [SET] (far right switch), turn power ON toenter initial set mode.

    Push [SET] one or more times until the rPt display ap-pears as shown below.

    Rotate the tuning dial to turn the auto repeater function tor1, r2 or OFF. r1: auto repeater is ON, tone encoder is OFF;

    r2: auto repeater is ON, tone encoder is ON. Push [PWR] momentarily to exit initial set mode.

    USING INITIAL SET MODE

    FREQUENCY RANGE DUPLEX DIRECTION145.200 145.495 MHz146.610 146.995 MHz DUP appears

    147.000 147.395 MHz DUP appears

    442.000 444.995 MHz DUP appears

    447.000 449.995 MHz DUP appears

    TDUP

    Auto repeater function isturned OFF

    Auto repeater function is ON,tone encoder is OFF.

  • 8/8/2019 Icom IC-207H Instruction Manual

    34/80

    MEMORY OPERATION6

    29

    I General descriptionThe transceiver has 150 regular memory channels, 10 scanedge memory channels (5 pairs) plus 2 call channels (by de-fault C1 is for VHF and C2 is for UHF, however both can beset to VHF or both to UHF as desired); each of these can beindividually programmed with the following data.

    Operating frequency (pgs. 15 19) Duplex direction (DUP or DUP ) and its offset frequency

    (pgs. 24, 25, 27) Subaudible tone encoder or tone squelch and its tone fre-

    quency (pgs. 24 26) Skip information* (p. 42)*Except for the scan edge memory channels.

    I Memory channel selection

    D Using the tuning dial Push [M/CALL] once or twice to display ! . Rotate the tuning dial to select the desired memory chan-

    nel. Only programmed memory channels can be selected.

    D Using [ Y ]/[Z ] switches Push [BAND] to select the desired band, if nec-

    essary.

    Push [MR] to select memory mode. Push [ Y ] or [Z ] several times to select the de-sired memory channel.

    Pushing [ Y ]/[Z ] more than 0.5 sec. activates a scan. If a scan is activated, push [ Y ] or [Z ] again to stop it.

    D Using the keypad Push [BAND] to select the desired band, if nec-

    essary.

    Push [MR] to select memory mode. Push [ G ENT] to activate the keypad for nu-meral input.

    Push 2 appropriate digit keys to input a chan-nel number. When inputting non-programmed channel numbers

    the previous memory channel appears. To select scan edge channels, B and A can be

    used for A and b respectively.

    MR

    YZ

    MR

    ENTC

  • 8/8/2019 Icom IC-207H Instruction Manual

    35/80

    6MEMORY OPERATION

    30

    I Programming a memory channelVFO mode settings, including the set mode contents such assubaudible tone frequency, etc., can be programmed into amemory channel.

    Set the desired frequency in VFO mode: Push [V/MHz] to select VFO mode. Set the frequency using the tuning dial. Set other data (e.g. tone frequency, etc.) if required.

    Push [S.MW] momentarily. ! and the memory channel number ash.

    Rotate the tuning dial to select the memory channel to be

    programmed. Memory channels not yet programmed are blank.

    Push [S.MW] for 1 sec. to program. 3 beeps may sound. Memory channel number automatically advances when continu-

    ing to push [S.MW] after programming.

    CONVENIENT Memory programming can be performed in versatile wayse.g. memory channel to the same (or different) memory chan-

    nel, memory channel to the call channel, etc.

    [EXAMPLE]: Programming 145.870 MHz into memory channel 20 via the remote controller.

    Push and Rotate for settingfreq., etc.

    Rotate

    Pushmomentarily

    Pushfor 1 sec. and continue pushing

    M

    HI 1 95 HI 1 95

    HI 1 95 HI 1 95

    HI 1 95

    BAND MWS.MW

    MWS.MW

    M

    HI 1 95

    VFO

  • 8/8/2019 Icom IC-207H Instruction Manual

    36/80

    6 MEMORY OPERATION

    31

    I Programming a memory channel via the microphoneMemory channel programming can be performedvia the microphone.

    Push [BAND] to select the desired band, if necessary. Set the desired frequency in VFO mode: Push [VFO] to select VFO mode. Set the frequency using the keypad. Set other data (e.g. offset frequency, duplex direction, subaudi-

    ble tone encoder ON/OFF and its frequency), if required.

    Push [FUNC] then [

    EMW] momentarily. Select the memory channel to be programmed:

    Push [ Y ] or [Z ] to select the memory channel (direct numeralinput cannot be used).

    Push [FUNC] then [ E MW] for 1 sec. to program. 3 beeps may sound and the VFO contents (including the sub-

    audible tone frequency, etc.) are programmed. Memory channel number advances when continuing to push

    [MW] after programming.

    [EXAMPLE]: Programming 145.870 MHz into memory channel 20 via the microphone.

    Push , Push thenmomentarily

    PushPush for 1 sec. andcontinue pushing

    BAND VFO

    8DUP+ 7DUP

    5MID1MONI 4HIGHCENT

    MW

    FUNC ACLR

    thenMW

    FUNC ACLR

    M

    HI 1 95 HI 1 95

    HI 1 95 HI 1 95

    HI 1 95

    M

    HI 1 95

    MW

  • 8/8/2019 Icom IC-207H Instruction Manual

    37/80

    6MEMORY OPERATION

    32

    I Transferring memorycontents

    This function transfers a memory channel s contents into aVFO (or another memory/call channel). This is useful whensearching for signals around a memory channel frequencyand for recalling the offset frequency, subaudible tone fre-quency, etc.

    Push [BAND] one or more times to select a band. Select the memory channel to be transferred: Select memory mode by pushing [M/CALL] once or twice ( !

    appears). Rotate the tuning dial to select the memory channel.

    Push [S.MW] momentarily, then rotate the tuning dial to se-lect another memory channel to transfer. To transfer to the VFO, push and hold [ (S.MW) MW] instead of

    pushing momentarily. Push and hold [ (S.MW) MW] to transfer when a momentary

    push was used in the previous step.

    Push

    +

    for 1 sec.

    MW

    FUNC ACLR

    MWS.MW

    TDUPHI

    M195

    TDUPHI

    195

    Push [BAND] to select the desired band, if nec-essary.

    Select the memory channel to be transferred: Push [MR] to select memory mode. Push [ Y ] or [Z ] to select the memory channel; or

    push [ G ENT] then push the desired memory chan-nel number (2 digits) to select the memory chan-nel directly.

    Push [FUNC] then [ E MW] momentarily, thenpush [ Y ] or [Z ] to select another memory

    channel to transfer. To transfer to the VFO, push [FUNC] then push and

    hold [ E MW] instead of pushing momentarily. Push [FUNC] then [ E MW] for 1 sec. to transfer

    when a momentary push was used in the previ-ous step.

    MW

  • 8/8/2019 Icom IC-207H Instruction Manual

    38/80

    6 MEMORY OPERATION

    33

    I Memory clearingContents of programmed memories can be cleared (blanked),if desired.

    Push [S.MW] momentarily. Select the memory channel to be cleared with the tuning

    dial. Push [S.MW] brie y, then a second time for 1 sec.

    3 beeps sound, then the frequency is cleared. ! ashes continuously. Scan edges and call channels cannot be cleared.

    Push any switch to stop the ashing.

    [EXAMPLE]: Clearing memory channel 20.

    NOTE:Be careful the contents of cleared memories CANNOTbe recalled. Scan edge channels 1A/1b cannot be cleared.

    Memory clearing may not be performed from themicrophone.

    Push Rotatemomentarily

    again for 1 sec.Push

    briefly, then pushPush any switch

    HI 1 95

    H I 1 95

    MWS.MW

    MWS.MW

    MWS.MW

    M

    HI 1 95M

    HI 1 95

    M

    H I 1 95

  • 8/8/2019 Icom IC-207H Instruction Manual

    39/80

    CALL CHANNEL OPERATION 7

    3

    I Calling up a call channelEach band has an independent call channel to store a most-often-used frequency for quick recall.

    Push [BAND] one or more times to select a band, if nec-essary.

    Push [M/CALL] once or twice to display a large C in thememory channel readout. While a call channel is displayed, pushing [BAND] toggles be-

    tween the 2 call channels.

    Push [V/MHz] or [M/CALL] to exit the call channel.

    Push [BAND] to select the desired band, if nec-essary.

    Push [ (MR)CALL] for 1 sec. to select the callchannel.

    Push [BAND] to toggle between the 2 callchannels.

    I Transferring call channelcontents

    Push [BAND] to select a band, if necessary. Select the call channel by pushing [M/CALL] once or twice.

    C1 or C2 appears push [BAND] to toggle between them. Push [S.MW] momentarily, then rotate the tuning dial to se-

    lect another memory channel to transfer. To transfer to the VFO, push and hold [ (S.MW) MW] instead of

    pushing momentarily. Push and hold [ (S.MW) MW] to transfer when a momentary

    push was used in the previous step.

    Push [BAND] to select the desired band, if nec-essary.

    Push [ (MR)CALL] for 1 sec. to select a callchannel, then push [BAND] to select the othercall channel, if desired.

    Push [FUNC], then [ E MW] momentarily. To transfer to the VFO, push [FUNC] then [ E MW] in-

    stead of pushing [ E MW] momentarily. Push [FUNC] then [ E MW] for 1 sec. to transfer

    when momentarily pushing [ E MW] in step .

    Large C shows a callchannel is selected.

    Small c shows VFO modewas selected from a callchannel.

    HI 195

    HI 195

    CALL

    MWA

  • 8/8/2019 Icom IC-207H Instruction Manual

    40/80

    7 CALL CHANNEL OPERATION

    35

    I Programming a call channelIn addition to an operating frequency, duplex information andsubaudible tone information (tone encoder or tone squelchON/OFF and its frequency) can be programmed into a callchannel.

    Push [BAND] to select a band, if necessary. Select the call channel by pushing [M/CALL] once or twice.

    ( C1 or C2 appears); then push [BAND] to change thecall channel, if desired.

    Set the desired frequency in VFO mode: Push [VFO] to select VFO mode. Set the frequency using the keypad. Set other data (e.g. offset frequency, duplex direction, subaudi-

    ble tone encoder ON/OFF and its frequency), if required. Push [ (S.MW) MW] for 1 sec. to program.

    [EXAMPLE]: Programming 145.120 MHz into the VHF call channel via the microphone.

    CONVENIENT The call channel can also be programmed from the VFO di-rectly (similar to memory programming).

    Push [BAND] to select the desired band, if nec-essary.

    Push [ (MR)CALL] for 1 sec. to select a callchannel, then push [BAND] to change the callchannel, if desired.

    Set the desired frequency in VFO mode: Push [VFO] to select VFO mode. Set the desired frequency using the keypad. Set other data, if required.

    Push [FUNC] then [ E MW] for 1 sec. to pro-gram.

    HI 1 95 HI 1 95

    BAND VFO 2SCAN

    5MID

    1MONI

    1MONI

    4HIGHCENT MW

    FUNC ACLRCALL

    MR Call channel VFO mode thenfor 1 sec.for 1 sec.

    Beep Beep Beep

    HI 1 95 HI 1 95

    MWA

  • 8/8/2019 Icom IC-207H Instruction Manual

    41/80

    SCRATCH PAD MEMORY 8

    3

    I What is a scratch padmemory?

    During VFO operation, the transceiver automatically memo-rizes operating frequency information, separate from regularmemory channels, when transmitting on a new frequency.The 5 previously operated frequencies for each band can berecalled (L1 to L5 appear for simplex frequencies; r1 to r5 ap-pear for duplex frequencies.

    NOTE: When memory mode is selected, the frequency isnot programmed into a scratch pad.

    I Calling up a scratch padmemory

    Select the call channel by pushing [M/CALL] once or twice.(A large C appears.) To transmit on the scratch pad memory, select the desired band

    in advance. Rotate the tuning dial to select a scratch pad memory.

    Previously transmitted frequency and one of L1L5 appears forsimplex memories (rotate [DIAL] left); one of r1r2 appears forduplex memories (rotate [DIAL] right).

    When rst applying power or after CPU resetting, scratch padmemories contain no data and therefore cannot be accessed.

    Push [V/MHz] or [M/CALL] to exit the scratch pad memory.

    The 5th scratch pad memory will be cleared when trans-mitting on a new frequency. If the transmit frequency isalready stored in a scratch pad memory, the scratch padmemory is not cleared but the order is changed.

    When transmitting on a scratch pad memory, the scratch

    pad memory becomes the 1st scratch pad memory andthe order is changed.

    Newest

    Oldest

    The oldest written frequency is cleared.

    Order is changed iftransmitting on thischannel.

    HI 1 95

    HI 1 95

    HI 1 95

    HI 1 95

    HI 1 95

    HI 1 95

  • 8/8/2019 Icom IC-207H Instruction Manual

    42/80

    8 SCRATCH PAD MEMORY

    37

    Push [BAND] to select a band, if necessary. Select a call channel by pushing [M/CALL] once or twice.

    A large C appears. Rotate the tuning dial to select the desired scratch pad

    memory. One of L1L5 appears.

    Push [ (S.MW) MW] momentarily. ashes to indicate VFO as the transferring channel.

    Rotate the tuning dial to select the desired memory chan-nel if required.

    Push and hold [ (S.MW) MW] to transfer.

    Push [BAND] to select the desired band, if nec-essary.

    Push [ (MR)CALL] for 1 sec. to select the callchannel.

    Push [ Z ] one or more times to select the de-sired scratch pad memory.

    Push [FUNC] then [ E MW] momentarily. ashes to indicate VFO as the transferring

    channel. Push [ Y ] or [Z ] to select the desired memory

    channel if required. Push [FUNC] then [ E MW] for 1 sec. to transfer.

    Push [BAND] to select the desired band, if nec-essary.

    Push and hold [ (MR)CALL] to select a call chan-nel.

    Push [ Z ] one or more times to select a duplexscratch pad memory. Once entering a scratch pad memory, [ Y ] can also

    be used for selection. Push [MR] or [VFO] to exit the scratch pad

    memory.

    I Transferring scratch padmemory contents

    Transferring scratch pad memory contents to the VFO is donesimilarly to transferring regular memory/call channel contents.

    Push for 1 sec.

    thenMW

    FUNC ACLR

    MWS.MW

    HI 1 95 1 95HI

    CALL

    MW

  • 8/8/2019 Icom IC-207H Instruction Manual

    43/80

    SCAN OPERATION 9

    3

    FULL SCAN Repeatedly scans all fre-quencies over the entireband. Used as the simplestscan without any prelimi-nary settings necessary.

    PROGRAMMED SCAN Repeatedly scans betweentwo user-programmed fre-quencies. Used for check-ing for frequencies withina specified range such asrepeater output frequen-cies, etc. 5 pairs of scanedges are available.

    SCAN RESUME CONDITION 5 resume conditions areavailable: 3 timer scans,pause scan and emptyscan. When receiving asignal, pause scan pausesuntil the signal disappears;timer scans pause for 5,10 or 15 sec. Emptypause scan pauses until asignal appears.

    MEMORY SCAN Repeatedly scans memorychannels except for skipchannels. Used for often-called channels and by-passing normally busychannels such as repeaterfrequencies.

    Bandedge

    Bandedge

    Scan

    Jump

    Bandedge

    Bandedge

    Scan

    Jump

    Scan edges

    SKIP

    SKIP

    M 1 M 5

    M 2 M 3 M 4

    M 6M 150 M 7

    Pausescan

    Receivinga signal

    Timerscan

    Emptypausescan

    Pausing

    Pausing

    2 sec.

    2 sec.

    I Scan typesScanning searches for transmitted signals automatically andmakes it easier to locate new stations for contact or listeningpurposes.

    Each band has 3 scan types and 5 resume conditions to suityour needs.

  • 8/8/2019 Icom IC-207H Instruction Manual

    44/80

    9 SCAN OPERATION

    39

    I Scan start/stopD

    Pre-operation Common setting: scan resume condition. (p. 43) For programmed scan:program the scan edges. (p. 40) For memory scan: program 2 or more memory chan-

    nels; set memory skip settings, if de-sired. (p. 42)

    D Operation Push [BAND] to select a band, if necessary.

    Select VFO mode for full/programmed scan with the[V/MHz] switch; or memory mode for memory scan with the[M/CALL] switch.

    Set the squelch to the point where noise is muted. Push for 1 sec. to start the scan.

    When the tone squelch is in use, starts a normal scan not tone scan.

    To change the scanning direction, rotate the tuning dial. The memory channel readout indicates the scan type as follows:

    SCAN

    SCAN

    To select the scan range while operating full/programmedscan, push [BAND] several times.

    To stop the scan, push [VMHz].

    Push [BAND] to select the desired band, if nec-essary.

    Push [VFO] to select VFO mode for full/pro-grammed scan; or push [MR] to select memorymode for memory scan.

    Push [ HY SQL] or [ AZ SQL] one or more timesto set the squelch just closed.

    Push [ SCAN] to start the scan. [Y ]/[Z ] also start the scan when pushed and held.

    To select the scan range while operatingfull/programmed scan, push [BAND] severaltimes.

    To stop the scan push [ E CLR].

    During full scanPush

    to select full scansand scan edgepairs in sequence.

    BAND

    HI 1 95

    During programmed scan

    Indicates scan edge channels. P1 stands for 1A/1b. P1 to P5 are available when

    they are programmed.

    HI 1 95

    During memory scanHI

    M1

    95

    SCAN2

    BAND

  • 8/8/2019 Icom IC-207H Instruction Manual

    45/80

    9SCAN OPERATION

    40

    I Programming scan edgesScan edges can be programmed in the same manner asmemory channels. Scan edges are programmed into pairs ofscan edge channels, 1A/1b to 5A/5b, in memory channels.

    Push [BAND] to select a band, if necessary. Set the desired frequency in VFO mode: Push [V/MHz] to select VFO mode. Set the frequency using the tuning dial. Set other data (e.g. offset frequency, etc.) if required.

    Push [S.MW] momentarily. ! and the memory channel number ashes.

    [EXAMPLE]: Programming 145.30 MHz and 145.80 MHz for the VHF scan edges 1A and 1b.

    Pushthenrotate

    Rotate

    Push

    momentarily and hold

    continue pushing

    Program 1b in the same manner.

    MWS.MW

    PushMWS.MW

    MWS.MW

    H I 1 95

    HI 1 95HI 1 95

    BAND

    HIM

    195 HI

    M1

    95

    Rotate the tuning dial to select a scan edge channel (1A to5A).

    Push [ (S.MW) MW] for 1 sec. to program. 3 beeps may sound and the frequency is programmed. Scan edge xb is automatically selected when continuing to push

    [(S.MW) MW] after programming. To program a frequency for the other pair of scan edges,

    1b to 5b, repeat steps to . If the same frequency is programmed into both scan edges, pro-

    grammed scan will not function.

  • 8/8/2019 Icom IC-207H Instruction Manual

    46/80

    9 SCAN OPERATION

    41

    I Programming scan edges viathe microphone

    Push [BAND] to select the desired band, if nec-essary.

    Set the desired frequency in VFO mode: Push [VFO] to select VFO mode. Set the frequency using the keypad.

    Push [FUNC] then [ E MW] momentarily. Push [ Y ] or [Z ] to select scan edge channels. Push [FUNC] then [ E MW] for 1 sec. to pro-

    gram.

    [EXAMPLE]: Programming 145.30 MHz and 145.80 MHz for the VHF scan edges 1A and 1b.

    Push Push thenmomentarily

    Program 1bin the samemanner.

    PushPush for 1 sec. andcontinue pushing

    VFO

    3PRIO 0VOL

    5MID1MONI 4HIGHC

    A

    ENT

    MW

    FUNC ACLR

    thenMW

    FUNC CLR

    Y

    HI 1 95 HI 1 95

    HI 1 95HI 1 95

    HIM

    195

    HIM

    195

    3 beeps may sound and the VFO contents (including the sub-audible tone frequency, etc.) are programmed.

    Memory channel number advances to the next scan edge chan-

    nel (1b to 5b) when continuing to push [ E MW] after program-ming.

    To program a frequency for the other scan edge channel,repeat steps and .

    MWA

  • 8/8/2019 Icom IC-207H Instruction Manual

    47/80

    9SCAN OPERATION

    42

    I Skip channel settingThe memory skip function speeds up scanning by checkingonly desired memory channels. Set the memory channels tobe skipped or scanned as follows.

    Push [BAND] to select the a band, if necessary. Select the memory channel to program or to cancel the

    skip function on: Select memory mode by pushing [M/CALL] once or twice. Rotate the tuning dial to select the memory channel.

    Push [SET] one or more times until CHS appears asshown above. Pushing [MONI] reverses the order of selection.

    Rotate the tuning dial to turn the skip function ON or OFFon the selected channel. ~ appears : The memory channel is skipped during

    (CHS-on) memory scan. ~ disappears : The memory channel is scanned during(CHS-OFF) memory scan.

    Push [V/MHz] to exit set mode.

    NOTE: Scan edge memory channels cannot be speci edas skip channels, however, they are skipped during mem-ory scan anyway.

    USING SET MODE

    The display shows thatmemory channel 10 is set asa skip channel.

    HIM

    195

    SKIP

    Push [BAND] to select the desired band, if nec-essary.

    Select the memory channel to program or tocancel the skip function on: Select memory mode by pushing [MR]. Push [ Y ] or [Z ] to select a memory channel.

    Push [ F SET] one or more times until CHS ap-pears as shown at left. Pushing [ G ENT] reverses the order of selection

    once entering set mode. Push [ Y ] or [Z ] to set or cancel the skip infor-

    mation. See item at left for skip indicator details.

    Push [ E CLR] to exit set mode.

    SETB

  • 8/8/2019 Icom IC-207H Instruction Manual

    48/80

    9 SCAN OPERATION

    43

    I Scan resumecondition

    The scan resume condition can be selected as timer, pauseor empty pause scan. The empty pause scan is useful fornding unused frequencies. The selected resume conditionis also used for priority watch. (p. 44)

    Push [BAND] to select a band, if necessary. Push [SET] one or more times until SCt or SCP appears

    as shown above. Pushing [MONI] reverses the order of selection. Cancel the DTMF memory encoder in advance. (p. 48)

    Rotate the tuning dial to set the desired timer. SCt-15 : Scan pauses 15 sec. while receiving a signal. SCt-10 : Scan pauses 10 sec. while receiving a signal. SCt-5 : Scan pauses 5 sec. while receiving a signal. SCP-2 : Scan pauses until the signal disappears and then

    resumes 2 sec. thereafter. SCt-EP : Scan pauses on a frequency that is not busy and

    resumes 2 sec. after a signal appears. Push [V/MHz] to exit set mode.

    The display shows that thescan resumes 15 sec. after itstops.

    HI 1 95

    USING SET MODE Push [BAND] to select the desired band, if nec-essary.

    Push [ F SET] one or more times until SCt orSCP appears as shown at left. Pushing [ G ENT] reverses the order of selection

    once entering set mode. Cancel the DTMF memory encoder in advance.

    (p. 48) Push [ Y ] or [Z ] to select the scan resume con-

    dition. See item above for scan resume condition details.

    Push [ E CLR] to exit set mode.

    SETB

  • 8/8/2019 Icom IC-207H Instruction Manual

    49/80

    PRIORITY WATCH 10

    4

    I Priority watch typesPriority watch checks for signals on a memory or call chan-nel every 5 sec. while operating on a VFO frequency. Thetransceiver has 3 priority watch types to suit your needs. Youcan transmit on the VFO frequency while the priority watchoperates.

    The watch resumes according to the selected scan resumecondition. See previous page for details.

    NOTE:

    Priority watch cannot be started from a scratch padmemory.

    The DTMF memory encoder is turned OFF when prioritywatch starts.

    If the pocket beep function is activated, the transceiverautomatically selects the tone squelch function when pri-ority watch starts.

    When SCt-EP is selected for the scan resume condi-tion, the priority watch pauses on a no-signal channel.(p. 43)

    MEMORY CHANNELWATCH

    MEMORY SCAN WATCH

    CALL CHANNEL WATCH

    VFOfrequency

    Memorychannel

    5 sec. 125 msec.

    VFOfrequency

    Mch 1Mch 0

    Mch 2

    Mch 150

    5 sec. 125 msec.

    SKIP

    VFOfrequency

    Callchannel

    5 sec.125 msec.

    While operating on a VFOfrequency, priority watch

    checks for a signal on theselected memory channelevery 5 sec. A memory channel with skip

    information can be watched.

    While operating on a VFOfrequency, priority watch

    checks for signals on eachmemory channel in se-quence. The memory skip function and

    memory area setting are use-ful to speed up the scan.

    While operating on a VFOfrequency, priority watchchecks for a signal on thecall channel every 5 sec.

  • 8/8/2019 Icom IC-207H Instruction Manual

    50/80

    10 PRIORITY WATCH

    45

    I Priority watch operation Push [BAND] to select a band, if necessary. Select VFO mode; then, set an operating frequency. Set the watching channel(s).

    For memory channel watch: Select the desired memory channel.For memory scan watch: Select memory mode; then, push for 1 sec. to startmemory scan.For call channel watch:

    Select the call channel by pushing [M/CALL] once or twice. Push for 1 sec. to start the watch.

    The transceiver checks the memory or call channel frequencyevery 5 sec.

    The watch resumes according to the selected scan resume con-dition. (p. 43)

    While the watch is pausing, pushing the selected band s[M/CALL] resumes the watch manually.

    Push [M/CALL] while the display shows the VFO frequencyto stop the watch.

    PRIO

    SCAN

    While pausing on thememory or call chan-nel, PRIO flashes.

    HIM

    195

    PRIO

    Push [BAND] to select the desired band, if nec-essary.

    Select VFO mode; then, set an operating fre-quency.

    Set the watching channel(s).For memory channel watch: Push [MR] then [ Y ] or [Z ] to select the desiredmemory channel.For memory scan watch:

    Push [MR] then [

    SCAN] to start the memoryscan.For call channel watch: Push and hold [ (MR)CALL] to select the callchannel.

    Push [ PRIO] to start the watch. The transceiver checks the memory or call channel

    frequency every 5 sec. The watch resumes according to the selected scan

    resume condition. (p. 43) To resume the watch manually while pausing, push

    [PRIO] or [ E CLR]. To stop the watch, push [ E CLR] once (or twice

    while watch pauses).

    PRIO3

    11

  • 8/8/2019 Icom IC-207H Instruction Manual

    51/80

    DTMF MEMORY ENCODER 11

    4

    I Programming a DTMF codeDTMF codes are used for autopatching, accessing repeaters,controlling other equipment, etc. The transceiver has 14DTMF memory channels (d0 d9, dA dd) for storage of often-used DTMF codes of up to 16 digits.

    NOTE: DTMF memory channels are commonly used forboth bands. Therefore, programming each band is notnecessary.

    Push for one sec. and d appears in place of the

    100 MHz digit as shown below.

    Push [SET] to enter the programming condition. Rotate the tuning dial to select the desired channel. Push [SET] or [MONI] to select the cursor. Rotate the dial to select a digit.

    E stands for M and F stands for #. Repeat steps and until the last digit is entered.

    The S/RF indicator shows the digit group. The indication in-creases every 6 digits.

    Select to clear the remaining digits when programming over apreviously used memory channel.

    Push [V/MHz] exit the programming condition.

    DTMF

    I Clearing the DTMF memorycontents

    Push for 1 sec. to turn the DTMF memory encoderON.

    Push [SET] to enter the programming condition. Rotate the tuning dial to select the desired channel. Push [SET] to activate the 1st digit. Rotate the tuning dial to select and clear the memory

    channel contents. Push the tuning dial to exit the programming condition.

    DTMF

    d appears in place ofthe 100 MHz digit.

    HI 1 95

  • 8/8/2019 Icom IC-207H Instruction Manual

    52/80

    11 DTMF MEMORY ENCODER

    47

    I Programming a DTMF code via the microphone

    [EXAMPLE]: Programming 5428AB453 into DTMF memory channel d4.

    DTMF codes can be directly programmed via thekeypad on the microphone. The contents can beoverwritten, but cannot be cleared via the micro-phone. See the previous page for clearing thecontents.

    Push [FUNC] then [ DTMF] to turn the DTMFmemory function ON. d appears in place of the 100 MHz digit.

    Push [ F SET] to enter the programming condi-tion.

    Push [ Y ] or [Z ] to select the desired channel. Push the desired digit keys.

    When the first digit is input, previous memory contents arecleared automatically.

    E stands for M and F stands for #. Push [ Y ] then [ Z ], and repeat this step when making a mistake. The S/RF indicator shows the digit group. The indication in-

    creases every 6 digits. Push [BAND] to exit the programming condition.

    The [ E CLR] key cannot be used to exit. If pushed, A is input,

    and the previously programmed data is erased. Reprogramagain in such a case.

    HI 1 95

    Push

    8DUP+5MID 5MID4HIGH 4HIGHACLR

    thenFUNCDTMF

    6LOW BSET

    BSET2SCAN 3PRIO BAND

    HI 1 95 HI 1 95 5HI 1 95 HI 1 9

    HI 1 95HI 1 95

    DTMF6

  • 8/8/2019 Icom IC-207H Instruction Manual

    53/80

    11DTMF MEMORY ENCODER

    48

    I Transmitting a DTMF codeD Using the DTMF memory function

    (automatic transmission)The selected DTMF code is transmitted at each push of thePTT switch when the DTMF memory encoder is turned ON.

    Push for 1 sec. to turn the DTMF memory encoderON. d appears in place of the 100 MHz digit.

    Push [SET] to enter the programming condition.

    Rotate the tuning dial to select the desired DTMF memorychannel. Push [PTT] to transmit the selected DTMF code.

    At each push of [PTT], the selected DTMF code is transmitted. The speaker emits the DTMF tones sent.

    Push for 1 sec. to cancel the function. d disappears.

    Push [FUNC] then [ DTMF] to turn the DTMFmemory encoder ON. d appears in place of the 100 MHz digit.

    Push [ F SET] to enter the programming condition. Push [ Y ] or [Z ] to select the desired channel. Push [PTT] to transmit the selected DTMF

    code. Each push of [PTT], transmits the DTMF code.

    Push [ E CLR] to cancel the function.

    DTMF

    DTMF

    DTransmitting a DTMF memory channel directly Push [FUNC] then [ DTMF] to turn the DTMF

    memory encoder ON. d appears in place of the 100 MHz digit.

    Push [DTMF-S], then push the desired DTMFchannel number. 0 to 9 and A to D are available for channel

    numbers. Push [DTMF-S] again to deactivate the DTMF

    setting. Push [ E CLR] to turn the DTMF memory en-coder OFF. When the DTMF memory encoder is turned ON con-

    tinuously, each push of the PTT transmits the previ-ously selected DTMF code.

    DTMF6

    DTMF S

  • 8/8/2019 Icom IC-207H Instruction Manual

    54/80

    11 DTMF MEMORY ENCODER

    49

    I DTMF speedThe rate at which DTMF memories send individual DTMFcharacters can be set to accommodate operating needs.

    Push [PWR] to turn power OFF. While pushing [SET] (far right switch), push [PWR] for 1

    sec. to turn power ON and enter initial set mode. Push [SET] or [MONI] to select the dtd display as shown

    above. Rotate the tuning dial to select the desired speed as shown

    in the table below. Push [PWR] momentarily to exit initial set mode.

    USING INITIAL SET MODE

    The display shows the fastestDTMF speed is selected.

    DISPLAY INTERVAL SPEEDdtd-1 100 msec. 5.0 cpsdtd-2 200 msec. 2.5 cps

    dtd-3 300 msec. 1.6 cpsdtd-5 500 msec. 1.0 cps

    cps=characters/second

    12

  • 8/8/2019 Icom IC-207H Instruction Manual

    55/80

    POCKET BEEP AND TONE SQUELCH 12

    5

    Push [BAND] to select the desired band, if nec-essary.

    Set the operating frequency. Program the subaudible tone frequency in set

    mode. See p. 26 for programming details.

    Push [FUNC] then [ T SQL S ] to turn thepocket beep ON.

    When a signal with the correct tone is received,the transceiver emits beep tones for 30 sec.and ashes S .

    Push [PTT] to answer or push [ E CLR] to stopthe beeps and ashing. Tone squelch is automatically selected. Pushing [FUNC] then [ TSQL] also selects the tone

    squelch. To cancel the function, push [FUNC] then

    [G T-OFF].

    D Calling a waiting station using pocket beepA subaudible tone matched with the stations frequency isnecessary. Use the tone squelch on the next page or a sub-audible tone encoder (pgs. 24, 25).

    I Pocket beep operationThis function uses subaudible tones for calling and can beused as a common pager to inform you that someone hascalled while you were away from the transceiver.

    D Waiting for a call from a speci c station Push [BAND] to select a band, if necessary. Set the operating frequency. Program the subaudible tone frequency in set mode.

    See p. 26 for programming details. Push [TONE] one or more times to indicate T SQL S

    in the function display. When a signal with the correct tone is received, the trans-

    ceiver emits beep tones and ashes S . Beep tones sound for 30 sec. To stop the beeps manually, push

    the tuning dial (or any key). S ashes continuously until step or . When receiving another call while S is ashing, no beeps sound.

    Push [PTT] to answer. Tone squelch is automatically selected when transmitting.

    Push [TONE] once or twice to cancel the function.

    SQL S8

    T-OFFC

  • 8/8/2019 Icom IC-207H Instruction Manual

    56/80

    Push [BAND] to select the desired band, if nec-essary.

    Set the operating frequency. Program the subaudible tone frequency in set

    mode. See p. 26 for programming details.

    Push [FUNC] then [ T SQL] to turn the tonesquelch ON.

    When the received signal includes the correcttone, the squelch opens and the signal can beheard. When the received signal includes and incorrect

    tone, the squelch does not open. However, the S/RFindicator shows the received signal strength.

    To open the squelch manually, push [ MONI]. Operate the transceiver in the normal way

    (push [PTT] to transmit; release [PTT] to re-ceive).

    To cancel the tone squelch, push [FUNC] then[G T-OFF].

    T SQL9

    12 POCKET BEEP AND TONE SQUELCH

    51

    I Tone squelch operationThe tone squelch opens only when receiving a signal with thesame pre-programmed subaudible tone.

    Push [BAND] to select a band, if necessary. Set the operating frequency. Program the subaudible tone frequency in set mode.

    See p. 26 for programming details. Push [TONE] one or more times until T SQL appears in

    the function display. When the received signal includes the correct tone, the

    squelch opens and the signal can be heard. When the received signal includes an incorrect tone, the squelch

    does not open. However, the S/RF indicator shows the receivedsignal strength.

    To open the squelch manually, push [MONI]. Operate the transceiver in the normal way (push [PTT] to

    transmit; release [PTT] to receive). To cancel the tone squelch, push [TONE].

    T SQL disappears from the function display. T-OFF

    C

  • 8/8/2019 Icom IC-207H Instruction Manual

    57/80

    12POCKET BEEP AND TONE SQUELCH

    52

    Push [BAND] to select the desired band, if nec-essary.

    Set the desired frequency to be checked for atone frequency e.g. repeater input frequency.

    Push [F-2] to start the tone scan. When the tone frequency is matched, the

    squelch opens and the tone frequency is pro-grammed into the selected mode such as VFO,memory/call channel or scratch pad memory.

    Push [ E CLR] to stop the scan.NOTE: The decoded tone frequency is programmed tem-porarily when a memory or call channel is selected.However, this will be cleared when overwriting the mem-ory/call channel.

    I Tone scanBy monitoring a signal that is being transmitted on a repeaterinput frequency, you can determine the tone frequency nec-essary to open a repeater.

    Push [BAND] to select a band, if necessary. Set the desired frequency to be checked for a tone fre-

    quency e.g. repeater input frequency. Push for 1 sec. to start the tone scan.

    To change the scanning direction, rotate the tuning dial. When the tone frequency is matched, the squelch opens

    and the tone frequency is programmed into the selectedmode such as VFO, memory/call channel or scratch padmemory. The tone scan pauses when a tone frequency is detected. The decoded tone frequency is used for the tone encoder or tone

    encoder/decoder depending on the tone squelch ON/OFF set-ting.

    Push [V/MHz] to stop the scan.

    T-SCAN

    HI 1 95

    T SQL9

    13

  • 8/8/2019 Icom IC-207H Instruction Manual

    58/80

    WIRELESS OPERATION13

    53

    I ConnectionWireless remote control is available when the following op-tions are used: HM-90 WIRELESS MICROPHONE EX-1759 INFRARED RECEIVER

    D Recommended connection

    I HM-90 WIRELESS MICROPHONEThe HM-90 s internal battery should be charged when the mi-crophone is not being held.Charging period: 1.5 hrs. with timer

    (or 8 hrs. when battery is exhausted)Operating period: 12 hrs (Operation : standby= 1 : 4)

    D Charging methodChoose one of the following methods: Connect the cable from the HM-90 to the EX-1759.

    D Turning the wireless remote ON/OFFWhen you use the HM-90 as a wired microphone, the wire-less remote control circuit can be turned OFF.

    LOCK

    AFC AFC-OFF PTT-M MW

    PGR

    CALL1 2 3 A

    4 5 6 B

    MR VFO CLR

    C-SQL DTMF D-OFF

    HIGH MID LOW SET

    The diagram shows thatthe wireless remote con-trol function is turnedON.

    Dip switch1 2 3 4

    ON

    OFF

    optional EX-1759 and HM-90

    IC-207H EX-1759 BC-96

    Use themicrophone scable

    HM-90

  • 8/8/2019 Icom IC-207H Instruction Manual

    59/80

    13WIRELESS OPERATION

    54

    I EX-1759 installationThe EX-1759 INFRARED RECEIVER can be installed for 2 differ-ent purposes depending on the HM-90 charger. This is be-cause the EX-1759 has both an infrared receiver and amicrophone connector which contains microphone chargingcapabilities.

    When using the connector for a microphone chargerAttach the EX-1759 to a suitable location for receiving in-frared signals and where it can be connected to a cable, e.g.the console, etc.

    NOTE: DO NOT attach the EX-1759 where it will be sub- ject to direct sunlight as it cannot detect infrared signalsunder such conditions.

    Optional infrared sub receiverAn optional EX-1513 INFRARED SUB RECEIVER is available toincrease the remote control reliability and extend the control-lable area. Connect the EX-1513 to the inside connector of

    the EX-1759.

    NOTE: The supplied microphone, HM-98, can be con-nected and used with the EX-1759, however, the optionalwireless microphone cannot be used in such a case.

    (When using the micconnector for miccharging.)

    The installation clip can be oriented in 1 of 4 ways.

    EX-1759

  • 8/8/2019 Icom IC-207H Instruction Manual

    60/80

    13 WIRELESS OPERATION

    55

    I HM-90 switches

    PTT SWITCH Push and hold to transmit; release to receive. Toggles between transmitting and receiving while the

    one-touch PTT function is in use.BAND SWITCHES [BAND SELECT Y ,Z ]Select a band.

    MONITOR SWITCH [MONI]Toggles between opening and closing the squelch.SQUELCH LEVEL UP/DOWN SWITCHES[Y SQL], [ Z SQL]Vary the squelch threshold point for noise mute.

    BANDSELECT

    MONI

    REMOTE CONTROLMICROPHONE

    VOLSQL

    LOCK

    JAPAN

    AFC AFC-OFF PTT-M MW

    PGR

    CALL1 2 3 A

    4 5 6 B

    M 0 # D

    MR VFO CLR

    C-SQL DTMF D-OFF

    SCAN

    MONI

    FUNC DTMFKEYDTMFMEMO

    MUTE SQL ENT

    7 8 9 CDUP DUP+ SIMP SPCH

    PRIO REAR LOCK DEMO

    TONE

    HIGH MID LOW SET

    T-SQL S T -S QL T -O FF

    Front and side panels Rear panel

    FREQUENCY UP/DOWN SWITCHES [UP], [DN] Push either switch to change the operating frequency,

    memory channel, set mode contents, etc. Push and hold either switch to start scanning.ACTIVITY INDICATORLights red while a key is pushed; lights green while theone-touch PTT function is in use.AUDIO VOLUME UP/DOWN SWITCHES[Y VOL], [ Z VOL]Adjust the accessed band s audio level.MODE INDICATORIndicates the microphone condition. Lights red when [FUNC] is pushed. Lights green when [DTMF KEY] is pushed. Lights orange when [DTMF MEMO] is pushed.LOCK SWITCH [LOCK]Locks all switches and keys on the microphone except forthe PTT switch.

    KEYPADUsed for controlling the transceiver, transmitting a DTMFmemory channel, etc.

  • 8/8/2019 Icom IC-207H Instruction Manual

    61/80

    13WIRELESS OPERATION

    56

    D Keypad

    KEY FUNCTION SECONDARY FUNCTION (After )FUNC OTHER FUNCTIONSCalls up a call channel. No secondary function.

    After :Input the appropriate digitfor frequency or memorychannel selection.

    After :Transmit the appropriateDTMF code.

    After :Transmit the appropriateDTMF memory contents.[0] to [9], [A] to [D] can beused for DTMF memory.

    DTMFMEMO

    DTMFKEY

    DENT

    DEMOSelects memory mode. No secondary function.

    Selects VFO mode. Turns the one-touch PTT function ONand OFF.

    Selects high output power. No secondary function.

    Selects mid-high output power. No secondary function.

    Selects low output power. Turns the DTMF memory function ON.

    Selects duplex. Turns the subaudible tone encoder ON.

    Selects + duplex. Turns the pocket beep function ON.

    Selects simplex. Turns the tone squelch function ON.

    Mutes audio signals. Starts and stops a priority watch.

    AFC

    CALL1

    AFC-OFF

    2MR

    PTT-M

    3VFO

    PGR

    4HIGH

    5

    C-SQL

    MID

    6

    DTMF

    LOW

    7DUP

    TONE

    8DUP +

    T-SQL S

    9SIMP

    T-SQL

    0MUTE

    PRIO

  • 8/8/2019 Icom IC-207H Instruction Manual

    62/80

    13 WIRELESS OPERATION

    57

    KEY FUNCTION SECONDARY FUNCTION (After )FUNC OTHER FUNCTIONSClears a digit before entry.

    Cancels the scan, priority watch, orDTMF memory function.

    Writes the VFO contents into the memorychannel or call channel.

    Advances the memory channel numberwhen continuously pushed after program-ming is completed.

    After :

    Transmit the appropriateDTMF code.

    [B MONI]Transmits a 1750 Hz tonecall signal for 0.5 sec.

    [A SQL]Transmits a 1750 Hz tone

    call signal while pushing.

    DTMFKEY

    Enters set mode and advances the setmode selection order.

    Turns the DTMF memory function OFF.

    Decreases the set mode selection orderafter entering set mode.

    NOTE:The IC-207H has no voice synthesizerfunction.

    Turns the subaudible tone encoder,pocket beep or tone squelch OFF.

    Sets the keypad for numeral input. Enters and exits demonstration mode.

    Toggles between opening and closingthe squelch.

    Starts and stops scanning.

    Selects 1 of the 4 preset squelch levels. Locks all the keys on the microphone key-pad.

    MW

    ACLR

    B

    D-OFF

    SET

    CSPCH

    T-OFF

    DENT

    DEMO

    M

    SCAN

    MONI

    #SQL

    REAR LOCK

  • 8/8/2019 Icom IC-207H Instruction Manual

    63/80

    13WIRELESS OPERATION

    58

    I Microphoneaddress

    The transceiver has 8 possible microphone addresses (in-cluding OFF) to help prevent interference from other HM-90WIRELESS MICROPHONES . Set both the microphone addressand microphone dip switch to the same value as follows.

    NOTE: When the supplied microphone is connected, thetransceiver rejects control signals from the HM-90 evenwhen the microphone address is matched.

    D Microphone address Push [PWR] to turn power OFF. While pushing [SET], turn power ON to enter initial set

    mode. Push [SET] a few times to

    select the Adr display asshown at right.

    Rotate the tuning dial to

    set the microphone ad-dress to 0 7 or to turn the microphone control OFF. When Adr-oF is selected, the transceiver rejects all control sig-

    nals from the HM-90. Push [PWR] momentarily to exit initial set mode.

    USING INITIAL SET MODE

    The display shows the mi-crophone address is set to 2.

    D Microphone dip switch

    Remove the switch cover from the microphone rear panel. Set the microphone dip switch and the microphone ad-

    dress to the same value as shown below. Replace the switch cover.

    MICROPHONEADDRESS

    DIP SWITCH

    S1 1 S1 2 S1 3

    Adr-0 OFF OFF OFF

    Adr-1 (default) ON OFF OFF

    Adr-2 OFF ON OFFAdr-3 ON ON OFF

    Adr-4 OFF OFF ON

    Adr-5 ON OFF ON

    Adr-6 OFF ON ON

    Adr-7 ON ON ON

    LOCK

    AFC AFC-OFF PTT-M MW

    PGR

    CALL1 2 3 A

    4 5 6 B

    MR VFO CLR

    C-SQL DTMF D-OFF

    HIGH MID LOW SET

    Dip switch

    ON

    OFF

    1 2 3

    (S1)Switch cover

    14

  • 8/8/2019 Icom IC-207H Instruction Manual

    64/80

    OTHER FUNCTIONS14

    59

    I Beep tones on/offYou can select silent operation by turning beep tones OFF oryou can select to have con rmation beeps sound at the pushof a switch by turning beep tones ON.

    Push [PWR] to turn power OFF. While pushing [SET], turn power ON to enter initial set

    mode. Push [SET] one or more times until bEP appears.

    Pushing [MONI] reverses the order of selection. Rotate the tuning dial to

    select the condition. bEP-oF : Beep tones are

    turned OFF. bEP-on : Beep tones are

    turned ON. Push [PWR] momentarily to exit initial set mode.

    I Time-out timerTo prevent accidental prolonged transmission with the one-touch PTT function, etc., the transceiver has a time-out timer.This timer cuts a transmission OFF after 3, 5, 15 or 30 min. ofcontinuous transmission. This timer can be cancelled (de-fault).

    Approx. 10 sec. before the time-out timer passes, the trans-ceiver emits a beep tone as a warning.

    Push [PWR] to turn power OFF. While pushing [SET], turn power ON to enter initial set

    mode. Push [SET] one or more times until tot appears.

    Pushing [MONI] reverses the order of selection.

    Rotate the tuning dial to select the desired time-out time orturn the timer OFF ( oF ).

    Push [PWR] momentarily to exit initial set mode.

    USING INITIAL SET MODE USING INITIAL SET MODE

    The display shows that the 5min. timer is selected.

    The display shows that thetime-out timer is cancelled.

    TOT

    The display shows that thebeep tones are turned ON.

  • 8/8/2019 Icom IC-207H Instruction Manual

    65/80

    14OTHER FUNCTIONS

    60

    I Auto power-offThe auto power-off function conveniently turns the transceiverpower OFF after a preset time in which no operations are per-formed. In this way, when you forget to turn the power OFF,the transceiver automatically turns itself OFF, thereby con-serving battery power.

    The time can be set to 30 min., 1 hr., 2 hrs. or turned OFF.The selected time is retained even when the transceiver isturned OFF via the auto power-off function. To cancel thefunction, select oF in step below.

    Push [PWR] to turn power OFF. While pushing [SET], turn power ON to enter initial set

    mode. Push [SET] one or more times until PoF appears.

    Pushing [MONI] reverses the order of selection. Rotate the tuning dial to

    select the desired autopower-off time or turn the

    timer OFF ( oF ). AO appears when an auto

    power-off time is set. Push [PWR] momentarily to exit initial set mode.

    I Cooling fansetting

    The transceiver has a heatsink and cooling fan to radiateheat. The cooling fan automatically turns ON while transmit-ting and remains ON for 2 min. after transmitting. The cool-ing fan can be activated continuously, if desired.

    Push [PWR] to turn power OFF. While pushing [SET], turn power ON to enter initial set

    mode. Push [SET] one or more times until FAn appears.

    Pushing [MONI] reverses the order of selection. Rotate the tuning dial to set the cooling fan to automatic

    (At) or continuous ( on ). Push [PWR] momentarily to exit initial set mode.

    USING INITIAL SET MODE USING INITIAL SET MODE

    The display shows that the30 min. timer is selected.

    AO

    The display shows that the

    cooling fan is set for automaticoperation.

    The display shows that the

    cooling fan is set for continuousoperation.

  • 8/8/2019 Icom IC-207H Instruction Manual

    66/80

    14 OTHER FUNCTIONS

    61

    I Microphone [F-1]/[F-2] keysSwitches on the transceiver s front panel can be assigned tothe microphone s [F-1] and [F-2] keys.

    Turn power OFF. While pushing the desired switch on the transceiver and

    [F-1] or [F-2] on the microphone, turn power ON. The switches function is programmed into the key ([F-1] or [F-2]).

    Default settingThe following functions are assigned to the [F-1]/[F-2] keys

    when rst applying power or after CPU resetting:[F-1]: selects output power; push and hold to select duplex

    setting[F-2]: selects a tone function or none at all; push and hold to

    start/stop tone scan

    I Display dimmerAdjust to suit lighting conditions and personal preference.

    Push and hold [SET] one or more times until d-1 d4 ap-pears as follows. Pushing [MONI] reverses the order of selection.

    Rotate the tuning dial toset the desired intensity. Intensity can be set from d1

    (dark) to d4 (bright). Push [V/MHz] to return to

    normal operation.

    USING SET MODE

    HI 1 95

    The display shows the displaybacklighting set to brightest.

  • 8/8/2019 Icom IC-207H Instruction Manual

    67/80

    14OTHER FUNCTIONS

    62

    I Squelch delayDuring operation, received signal strength often uctuates.This can result in annoying repeated opening and closing ofthe squelch during reception of the same signal. The IC-207Hhas a built-in squelch delay function which helps prevent this.When both stations are operating from a xed location, thisfunction should be set to short e.g. packet operation.

    Push [PWR] to turn power OFF. While pushing [SET], turn power ON to enter initial set

    mode. Push [SET] one or more times until Sqt appears.

    Pushing [MONI] reverses the order of selection. Rotate the tuning dial to

    set the squelch delay toL (long) or S (short).

    Push [PWR] momentarilyto exit initial set mode.

    USING INITIAL SET MODE

    The display shows the squelchdelay function is set to short.

    I Demonstration displayA demonstration function is available at power ON. This func-tion gives you a quick visual introduction to the function dis-play indicators.

    While pushing [BAND], push [PWR] to turn power ON. The transceiver cycles through a visual tour of the function dis-

    play indicators. Push any switch to exit demonstration mode and enter the

    normal operating condition temporarily.

    NOTE: The transceiver automatically returns to demon-stration mode after 2 min. in which no operations are per-formed. To deactivate the demonstration displaypermanently, turn power OFF, then while pushing [BAND],turn power ON again.

  • 8/8/2019 Icom IC-207H Instruction Manual

    68/80

    14 OTHER FUNCTIONS

    63

    I Packet operation

    D Data speedFor packet operation the transceiver can be set to one of twodata speeds: 1200 bps (default) or 9600 bps.

    Push [PWR] to turn power OFF. While pushing [SET], turn power ON to enter initial set

    mode. Push [SET] one or more times until bPS appears.

    Pushing [MONI] reverses the order of selection.

    Rotate the tuning dial toselect the desired dataspeed.

    Push [PWR] momentarily to exit initial set mode.

    USING INITIAL SET MODE

    The display shows the dataspeed set to 1200 bps.

    The display shows the dataspeed set to 9600 bps.

    NOTE:For 1200 bps operation Disconnect the microphone plug from the microphone

    connector during data transmission, otherwise the datasignal and voice signal are simultaneously transmitted.

    For 9600 bps operation When the transceiver is set for 9600 bps data transmis-

    sion in INTIAL SET MODE, the microphone signal is au-

    tomatically cut. Therefore, it is not necessary todisconnect the microphone plug from the connector inthis case.

    When pushing [PTT] during data transmission, datatransmission is interrupted and voice signals have prior-ity.

  • 8/8/2019 Icom IC-207H Instruction Manual

    69/80

    NOTE: Read the instructions supplied with your TNC carefully

    before attempting packet operation with the IC-207H.

    Pin t AF OUT is for 1200 bps operation only. This pincannot be used for 9600 bps operation.

    Over modulation may degrade signal quality. If you ndthat many transmissions are failing, re-adjust the modu-lation level.

    14OTHER FUNCTIONS

    64

    D 1200 bps packet operationq Connect the IC-207H and a TNC as illustrated below.

    w Set the TNC for transmit.e Set transmit delay on the TNC to 30 50.r Adjust the TNC frequency deviation if necessary.

    When using a deviation meter: Adjust the output of the TNC so that frequency deviation is in therange 3 to 4 kHz.

    When NOT using a deviation meter: A receiver or transceiver is needed to monitor the transmission compare the received audio output level when receiving a TNCmodulated signal with high level voice signals using the micro-phone. Then adjust the TNC modulated signal to a lower levelthan the voice modulated signal.

    DATA IN

    SQL

    PTT

    RX AUDIO

    GND

    TX AUDIO

    TNC SIDE

    GND

    PTTP

    SQ

    AF OUT

    14

  • 8/8/2019 Icom IC-207H Instruction Manual

    70/80

    14 OTHER FUNCTIONS

    65

    NOTE: When using the PTTP terminal for packet operation, no

    voice signals are transmitted from the microphone.

    When pushing [PTT] during data transmission, datatransmission is interrupted and the voice signal takes pri-ority.

    Read the instructions supplied with your TNC carefullybefore attempting packet operation with the IC-207H.

    Pin r DATA OUT is for 9600 bps operation only. This pincannot be used for 1200 bps operation.

    D 9600 bps high speed packet operationThe IC-207H supports 2 modes of 9600 bps packet opera-tion: G3RUH and GMSK.

    q Connect the IC-207H and a TNC as illustrated below.

    w G3RUH mode can handle 16 kinds of modulated waveforms in order to maintain a communication link.

    e Set the TNC s TX DELAY to 30 50.r Adjust the TNC frequency deviation if necessary (see page

    at right).

    DATA IN

    SQL

    PTT

    RX AUDIO

    GND

    TX AUDIO

    TNC SIDE

    GND

    PTTP

    SQ

    DATA OUT

    14

  • 8/8/2019 Icom IC-207H Instruction Manual

    71/80

    14OTHER FUNCTIONS

    66

    D Adjusting the transmit signal output fromthe TNC

    When setting data transmission speed to 9600 bps, the DATAsignal coming from the TNC is applied exclusively to the in-ternal limiter circuitry to automatically maintain band width.

    NEVER apply data levels from the TNC of over 0.6 Vp-p, oth-erwise the transceiver will not be able to maintain the bandwidth and may possibly interfere with other stations.

    1. When using a level meter or synchroscope, adjust the TXaudio output level ( DATA IN level) from the TNC as follows.0.4 Vp-p (0.2 Vrms): recommended level0.2 Vp-p 0.5 Vp-p (0.1 Vrms 0.25 Vrms): acceptable level

    2. When NOT using a measuring device.q Connect the IC-207H to a TNC.w Enter a test mode ( CAL, etc.) on the TNC, then transmit

    some test data.e When the transceiver fails to transmit the test data or

    transmits sporadically (TX indicator doesnt appear or

    ashes): Decrease the TNC output level until the transmit indicatorlights continuously.When transmission is not successful even though the TX indicator lights continuously: Increase the TNC output level.

    MAINTENANCE15

  • 8/8/2019 Icom IC-207H Instruction Manual

    72/80

    MAINTENANCE15

    67

    I Troubleshooting If your transceiver seems to be malfunctioning, please checkthe following points before sending it to a service center.

    PROBLEM POSSIBLE CAUSE SOLUTION REF.No power comes on. Power connector has a poor contact.

    Polarity of the power connection is reversed.

    Blown fuse.

    Check the connector pins. Reconnect the power cable observing the

    proper polarity. Replace the fuse, if damaged. Check the cause, then replace the fuse.

    pgs.13, 69p. 69

    No sound comes from thespeaker.

    Volume level is too low. The squelch level is set too tight. A selective call or squelch function is activated

    such as pocket beep or tone squelch.

    Rotate [VOL] clockwise. Set the squelch level to the threshold. Turn the appropriate function OFF.

    p. 20p. 20pgs.50, 51

    Sensitivity is low and onlystrong signals are audible.

    Antenna feedline or the antenna connector sol-der has a poor contact or is short circuited.

    Check, and if necessary, replace the feedline orsolder the antenna connector again.

    p. 14

    No contact possible with an-other station.

    The transceiver is set to semi-duplex. The other station is using tone squelch.

    Set to simplex. Turn ON the tone squelch function.

    p. 24p. 51

    Repeater cannot be ac-cessed.

    Wrong offset frequency is programmed. Wrong subaudible tone frequency is pro-

    grammed.

    Correct the offset frequency. Correct the subaudible tone frequency.

    p. 27p. 26

    Frequency cannot be set. The frequency lock function is activated.

    Priority watch is paused on the watching fre-quency.

    Turn the function OFF.

    Push [ (M/CALL)PRIO] to resume the watch.

    p. 16

    p. 45

    Frequency cannot be set viathe microphone.

    The frequency lock function is activated.

    The microphone keypad lock function is acti-vated.

    Priority watch is paused on the watching fre-quency.

    Push and hold to deactivate the fre-quency lock function.

    Push [FUNC], then [ A 16KEY LOCK] to deacti-vate the microphone keypad lock function.

    Push [ (M/CALL)PRIO] to resume the watch.

    LOCK p. 16

    p. 16

    p. 45

    15

  • 8/8/2019 Icom IC-207H Instruction Manual

    73/80

    15MAINTENANCE

    68

    PROBLEM POSSIBLE CAUSE SOLUTION REF.

    Some memory channelscannot be selected via themicrophone keypad.

    The input channel number has not yet been pro-grammed.

    Rotate the tuning dial to check whether thechannel has been programmed or not.

    p.29

    Scan does not operate. Squelch is open. The selected scan edge memory channels (e.g.

    1 A and 1b) have the same frequencies (for pro-grammed scan).

    Only 1 memory channel is programmed or otherchannels are set as skip channels.

    Priority watch is activated.

    Set the squelch to the threshold point. Reset the scan edges.

    Program other memory channels or cancel thememory skip function in the desired channels.

    Turn the function OFF.

    p. 20p. 40

    pgs.30, 42p. 45

    Transmission is automati-cally cut off.

    Time-out timer is activated. Set the timer to OFF. p. 59

    Transmission continueseven when the PTT is re-leased.

    One-touch PTT function is activated. Turn the function OFF. p. 23

    The function display shows

    erroneous information.

    The CPU is malfunctioning. Reset the CPU. p. 69

    15

  • 8/8/2019 Icom IC-207H Instruction Manual

    74/80

    15 MAINTENANCE

    69

    I Fuse replacementIf the fuse blows or the transceiver stops functioning, nd the

    source of the problem if possible, and replace the damagedfuse with a new, rated one (FGB 20 A) as shown in the dia-gram below.

    I Partial resettingIf you want to initialize the operating conditions without clear-ing the memory contents, etc., a partial reset function is avail-able for the transceiver.

    While pushing [V/MHz], turn power ON to partially reset thetransceiver.Initialized settings: VFO frequency, SET mode settings.Retained settings: Memory channels, call channels, offset

    freq. in memory/call, DTMF memory, ini-tial SET mode settings.

    I Resetting the CPUThe function display may occasionally display erroneous in-

    formation, (e.g. when first applying power). This may becaused externally by static electricity, or by other factors.

    If this problem occurs, turn power OFF. After waiting a fewseconds, turn power ON again. If the problem persists, per-form the following procedure.

    Partial resetting is alternatively available. See previous sec-tion for details.

    Push [PWR] to turn power OFF. While pushing [SET] and [S.MW], turn power ON.

    CLEAr appears and the transceiver is reset.

    CAUTION: Resetting the transceiver CLEARS allmemory information, and initializes all values in the trans-

    SPECIFICATIONS 16

  • 8/8/2019 Icom IC-207H Instruction Manual

    75/80

    SPECIFICATIONS 16

    7

    General Frequency coverage

    VERSION VHF UHF144 148 MHz

    440 450 MHz

    Asia144 148 MHz

    430 440 MHz

    Europe 144 146 MHz 430 440 MHz

    Italy144 148 MHz 430 440 MHz

    TxRx 136 174 MHz* 1

    TxRx 136 174 MHz* 1 400 479 MHz* 2

    *1Guaranteed frequency coverage is 144 148 MHz.*2Guaranteed frequency coverage is 430 440 MHz.

    Mode : FM, AM*(*U.S.A. ver. only; 118 135.995 MHz)

    Antenna impedance : 50 (SO-239 ) Scanning speed : 16 ch/sec. (programmed scan)

    8 ch/sec. (memory scan) Power supply requirement : 13.8 V DC 15% Usable temperature range : 10 C to +60 C; +14 F to +140 F Dimensions : 140(W) 40(H) 184.5(D) mm

    (projections not included) 5 1 2(W) 19 16 (H) 71 4(D) in Weight : 1.17 kg; 2.6 lb

    Transmitter Modulation system : Variable reactance frequency

    modulation Max. frequency deviation : 5.0 kHz Spurious emissions : Less than 60 dB

    Microphone impedance : 600 (8-pin modular) Output power and current drain:

    Receiver Receive system : Double conversion superheterodyne Intermediate frequencies : 1st 46.05 MHz 2nd 450 kHz Sensitivity (for 12 dB SINAD) : Less than 0.18 V Squelch sensitivity : Less than 0.13 V (at threshold) Selectivity : More than 12 kHz/ 6 dB

    Less than 30 kHz/ 60 dB Spurious response : M ore than 60 dB

    rejection ratio Audio output power : More than 2.0 W at 10% distortion

    with the 8 internal speaker Current drain :

    Max rated audio 1.0 AStandby 0.8 A

    CONDITION POWER

    144 MHz

    50 W20 W10 W

    430(440) MHz

    12.0 A6.5 A5.5 A

    11.0 A35 W20 W 6.5 A10 W 5.5 A

    High

    Mid-LowMid-High

    HighMid-HighMid-Low

    All stated speci cations are subject to change without notice orobligation.

    CURRENT

    U.S.A.118 174 MHz* 1Rx

    Tx

    5 W 4.5 ALow

    5 W 4.5 ALow

    OPTIONS17

  • 8/8/2019 Icom IC-207H Instruction Manual

    76/80

    OPTIONS17

    71

    Some of the following options may not be available due tovariations in local electrical standards, etc. If you have anyquestions regarding options please consult your Icom Dealer.

    D SpeakersSP-7 EXTERNAL SPEAKERFor base station use. Cable length: 1.0 m; 3.3 ftSP-10 EXTERNAL SPEAKERCompact design. Cable length: 1.5 m; 4.9 ftSP-12 EXTERNAL SPEAKERSlim-type. Cable length: 2.0 m; 6.6 ft

    D Separation accessoriesOPC-600/601 SEPARATION CABLEFor operation with the front panel detached.

    Cable lengthOPC-600: 3.5 m; 11.5 ft OPC-601: 7.0 m; 23.0 ftMB-58 REMOTE CONTROLLER BRACKETMounts the remote con