ICL-MBSG2-4 JOB CATALOG MBS G2 Retractable Recessed Multiple … · MBS G2 Retractable Recessed...

5
Ceiling Cut Out: 7 9/16” x 26 7/8” Horizontal Adjustability: 312º Verical Adjustability: 60º (full pull down) / 30º (recessed) 60° 2 5/8” 6 1/4” 1 3/4” 13 5/8” 28 1/ 2” 25 5/8” 27 1/4” 6 1/4” 8” ICL-MBSG2-4 MBS G2 Retractable Recessed Multiple (4) Head - Gen 2 FEATURES Heavy duty die-cast construction Retractable pull down with vertical locking 312° Horizontal rotation 60° Vertical tilt at full pull down position / 30° Vertical tilt at recessed position LED LIGHT ENGINE (PER HEAD) 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning LED mounted to die-cast / extruded aluminum heat sink >50,000 hours average rated life at 70% output ELECTRICAL SYSTEM Constant current LED driver Power factor >.9, 50/60Hz Multiple dimming drivers available This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty. HOUSING The luminaire is type Non-IC. Insulation must be kept at a minimum of 3” away from fixture. The inner trim is constructed of 20GA steel painted black, white or silver. The internal wire bundles are locked and covered with a glass sleeve. The housing is supplied with a plate to allow the junction box to be accessible from below the ceiling. MOUNTING The luminaire can accommodate a ½” to 1 ¼” ceiling thickness. The fixture is supplied with channel brackets that allow up-to 5” vertical adjustment. Compatible with C-channel, flat bar, wood joist bar and EMT. Bar hangers must be ordered separately. C-channel are recommended for T-bar ceilings. Wood joist bar hangers are not for use in T-bar ceilings. FLANGED TRIM Extruded trim frame includes torsion springs for convenient installation or removal from the housing. EMERGENCY Remote or integral test switch included. External battery operates one LED load of up to 7W at a minimum of 600 lumens for 90 minutes. Integral test switch adds 2” to the depth of luminaire. ACCESSORIES Luminaire will accommodate (2) Filter Media per head, an accessory holder or snoot is required per head. (Note: Accessory holder and snoot can not be used at the same time.) LISTING/WARRANTY ETL listed to US and Canadian standards for damp locations. 5-Year Intense LED Limited Warranty Notes: 1. Consult factory for lead times 2. Dimming available in 120V 3. DMX512 RDM available with L3 & L4 only 4. Access above ceiling required 5. EM7T adds 2” depth ELECTRICAL DATA LED Light Engine Wattage Per Head 1 CCT / CRI Nominal Delivered Lumens 2, 3 L1 L2 L3 L4 10W 14W 20W 29W 3000K / 82 CRI 3000K / 82 CRI 3000K / 82 CRI 3000K / 82 CRI 1100lm 1500lm 2000lm 2600lm 1 System Wattage include driver and LED Module consumption 2 Delivered lumens will vary depending on CCT, CRI and optic 3 Data shown is per individual head Trim Example: ICL-MBSG2L330-4-BW-24 Luminaire Wattage CCT / CRI Driver Voltage Finish Optic Option ICL-MBSG2 L1 L2 L3 L4 (40 Watts) (56 Watts) (80 Watts) (116 Watts) 27-4 279-4 30-4 309-4 35-4 359-4 1 41-4 419-4 1 (2700K / 82 CRI) (2700K / 92 CRI) (3000K / 82 CRI) (3000K / 92 CRI) (3500K / 82 CRI) (3500K / 92 CRI) (4100K / 82 CRI) (4100K / 92 CRI) blank -DELV 2 -D10 -ED10V1 -ED10V01 -LUT -LUT2 2 -DMXR 3 (Non-Dimming) (ELV Dimming) (0-10V Dimming 10%) (eldoLED 0-10V 1%) (eldoLED 0-10V 0.1%) (Lutron ® LDE1 EcoSystem 1%) (Lutron ® LTEA2W 2-Wire 1%) (DMX512 RDM 0.1%) blank 27 (120V) (277V) -BW -WW (Black Interior/ White Trim) (White Interior/ White Trim) -16 -24 -32 -50 -SF (16° SP) (24° NFL) (32° FL) (50° WFL) (Square FL) I100 I200 I400 EM7 4 EM7T 4, 5 (C-Channel Bar Hangers) (Flat Bar Bar Hangers) (Wood Joist Bar Hangers) (7W Emergency Backup w/ Remote Test Switch IOTA part #ILB-CP07-A) (7W Emergency Unit w/Integral Test Switch IOTA part #ILB-CP07-R) Accessory Holder LHRS LHRSW (Accessory Holder, Black) (Accessory Holder, White) Filters PFL-CL1-S68 PFL-CL2-S68 PFL-CL4-S68 (Prismatic Spread Lens) (Linear Spread Lens) (Soft Focus Lens) Louver & Snoot PFLMB-16 (Hex Louver) JOB NAME CATALOG NUMBER NOTES TYPE MB-MULTIPLES L/M-0515:19 P-22 INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321. © 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Transcript of ICL-MBSG2-4 JOB CATALOG MBS G2 Retractable Recessed Multiple … · MBS G2 Retractable Recessed...

Page 1: ICL-MBSG2-4 JOB CATALOG MBS G2 Retractable Recessed Multiple … · MBS G2 Retractable Recessed Multiple (4) Head - Gen 2 ... Remote or integral test switch included. External battery

Ceiling Cut Out: 7 9/16” x 26 7/8”Horizontal Adjustability: 312ºVerical Adjustability: 60º (full pull down) / 30º (recessed)

60°2 5/8”

6 1/4”

1 3/4”

13 5/8”

28 1/2”

25 5/8”27 1/4”

6 1/4” 8”

ICL-MBSG2-4MBS G2 Retractable Recessed Multiple (4) Head - Gen 2

FEATURES ■ Heavy duty die-cast construction ■ Retractable pull down with vertical locking ■ 312° Horizontal rotation ■ 60° Vertical tilt at full pull down position / 30° Vertical tilt at recessed position

LED LIGHT ENGINE (PER HEAD) ■ 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning

■ LED mounted to die-cast / extruded aluminum heat sink ■ >50,000 hours average rated life at 70% output

ELECTRICAL SYSTEM ■ Constant current LED driver ■ Power factor >.9, 50/60Hz ■ Multiple dimming drivers available ■ This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty.

HOUSINGThe luminaire is type Non-IC. Insulation must be kept at a minimum of 3” away from fixture. The inner trim is constructed of 20GA steel painted black, white or silver. The internal wire bundles are locked and covered with a glass sleeve. The housing is supplied with a plate to allow the junction box to be accessible from below the ceiling.

MOUNTINGThe luminaire can accommodate a ½” to 1 ¼” ceiling thickness. The fixture is supplied with channel brackets that allow up-to 5” vertical adjustment. Compatible with C-channel, flat bar, wood joist bar and EMT. Bar hangers must be ordered separately. C-channel are recommended for T-bar ceilings. Wood joist bar hangers are not for use in T-bar ceilings.

FLANGED TRIMExtruded trim frame includes torsion springs for convenient installation or removal from the housing.

EMERGENCYRemote or integral test switch included. External battery operates one LED load of up to 7W at a minimum of 600 lumens for 90 minutes. Integral test switch adds 2” to the depth of luminaire.

ACCESSORIESLuminaire will accommodate (2) Filter Media per head, an accessory holder or snoot is required per head. (Note: Accessory holder and snoot can not be used at the same time.)

LISTING/WARRANTY ■ ETL listed to US and Canadian standards for damp locations. ■ 5-Year Intense LED Limited Warranty

Notes: 1. Consult factory for lead times2. Dimming available in 120V3. DMX512 RDM available with L3 & L4 only4. Access above ceiling required5. EM7T adds 2” depth

ELECTRICAL DATA

LED Light Engine Wattage Per Head 1 CCT / CRI Nominal Delivered Lumens 2, 3

L1L2L3L4

10W14W20W29W

3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI

1100lm1500lm2000lm2600lm

1 System Wattage include driver and LED Module consumption2 Delivered lumens will vary depending on CCT, CRI and optic3 Data shown is per individual head

Trim Example: ICL-MBSG2L330-4-BW-24

Luminaire Wattage CCT / CRI Driver Voltage Finish Optic Option

ICL-MBSG2 L1L2L3L4

(40 Watts)(56 Watts)(80 Watts)(116 Watts)

27-4279-430-4309-435-4359-41

41-4419-41

(2700K / 82 CRI)(2700K / 92 CRI)(3000K / 82 CRI)(3000K / 92 CRI)(3500K / 82 CRI)(3500K / 92 CRI)(4100K / 82 CRI)(4100K / 92 CRI)

blank-DELV2

-D10-ED10V1-ED10V01-LUT-LUT22

-DMXR3

(Non-Dimming)(ELV Dimming)(0-10V Dimming 10%)(eldoLED 0-10V 1%)(eldoLED 0-10V 0.1%)(Lutron® LDE1 EcoSystem 1%)(Lutron® LTEA2W 2-Wire 1%)(DMX512 RDM 0.1%)

blank27

(120V)(277V)

-BW

-WW

(Black Interior/White Trim)(White Interior/White Trim)

-16-24-32-50-SF

(16° SP)(24° NFL)(32° FL)(50° WFL)(Square FL)

I100I200I400EM74

EM7T4, 5

(C-Channel Bar Hangers)(Flat Bar Bar Hangers)(Wood Joist Bar Hangers)(7W Emergency Backup w/ Remote Test SwitchIOTA part #ILB-CP07-A)(7W Emergency Unit w/Integral Test SwitchIOTA part #ILB-CP07-R)

Accessory Holder

LHRSLHRSW

(Accessory Holder, Black)(Accessory Holder, White)

Filters

PFL-CL1-S68PFL-CL2-S68PFL-CL4-S68

(Prismatic Spread Lens)(Linear Spread Lens)(Soft Focus Lens)

Louver & Snoot

PFLMB-16 (Hex Louver)

JOB NAME

CATALOG NUMBER

NOTES TYPE

MB-MULTIPLES L/M-0515:19 P-22

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 2: ICL-MBSG2-4 JOB CATALOG MBS G2 Retractable Recessed Multiple … · MBS G2 Retractable Recessed Multiple (4) Head - Gen 2 ... Remote or integral test switch included. External battery

ICL-MBSG2L130-1Report #: ILL-08232016-03.3 (-16) ILL-08232016-02.3 (-24) ILL-08232016-01.3 (-32) ILL-08232016-05.3 (-50)

APPLICATION DATA:

W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

Photometric Data shown is compiled per head. For multi-light photometrics consult factory.

768

1152

1537 10° 20°

Watts: 9.8Lumens: 1112 LPW: 113 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

15331494122488526735

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

85616476118445821415

2140

4231

6421

8561 10°

80°

70°

60°

50°

40°

30°20°

16° Spot (16)

Watts: 9.8Lumens: 1229 LPW: 125 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

31162785143966511613

779

1558

2337

3116 10°

80°

70°

60°

50°

40°

30°20°

24° Narrow Flood (24)

Watts: 9.8Lumens: 1056 LPW: 108 CCT: 3000K

50°

40°

645

1280

1936

2581 10° 20°

32° Flood (32)

Watts: 9.8Lumens: 1082 LPW: 110 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

25812498151768813914

80°

70°

60°

50°

40°

30° 30°

0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL

D FC W L D C FC W L D C FC W L D C FC W L

ICL-MBSG2L130-1-163000K / 16° Spot

Per Head

6’8’

10’12’

23813485.659.5

1’ 7”2’ 2”2’ 8”3’ 4”

1’ 7”2’ 2”2’ 8”3’ 4”

6’8’

10’12’

3’4’5’7’

15285.654.838.2

2’ 4”2’ 11”3’ 8”4’ 4”

1’ 9”2’ 6”3’ 2”3’ 9”

3’4’5’6’

5’6’8’10’

21412079.553.6

1’ 6”2’ 1”2’ 7”3’ 3”

3’ 1”4’

4’ 9”5’ 11”

3’4’5’6’

2’2’3’4’

32017112980

1’ 2”1’ 3”1’ 6”1’ 11”

1’ 3”1’ 11”1’ 8”2’ 5”

ICL-MBSG2L130-1-243000K / 24° Narrow Flood

Per Head

6’8’

10’12’

86.648.731.221.6

3’4’5’6’

3’4’5’6’

6’8’

10’12’

3’4’5’6’

58.633

21.114.7

3’ 8”4’ 10”

6’7’ 3”

3’ 4”4’ 4”5’ 4”6’ 5”

3’4’5’6’

4’6’7’9’

8146.930

20.8

2’ 9”3’ 6”4’ 4”5’ 3”

4’ 6”5’ 11”7’ 4”8’ 9”

3’4’5’6’

2’2’3’4’

12565.947

31.3

1’ 8”2’ 5”2’ 10”3’ 6”

1’ 10”2’ 8”3’ 1”3’ 9”

ICL-MBSG2L130-1-323000K / 32° Flood

Per Head

6’8’

10’12’

71.740.325.817.9

3’ 7”4’ 10”

6’7’ 4”

3’ 7”4’ 10”

6’7’ 4”

6’8’

10’12’

3’4’4’5’

50.128.218.312.8

4’ 2”5’ 7”6’ 11”8’ 2”

3’ 9”5’ 1”6’ 2”7’ 5”

3’4’5’6’

4’5’6’8’

75.742.927

18.9

3’3’ 9”4’ 11”5’ 10”

4’ 8”6’ 1”7’ 8”9’ 2”

3’4’5’6’

2’3’3’4’

10756.738.826.8

2’2’ 11”3’ 4”

4’

2’ 4”3’ 1”3’ 8”4’ 5”

ICL-MBSG2L130-1-503000K / 50° Wide Flood

Per Head

6’8’

10’12’

42.624

15.310.6

6’ 4”8’ 5”10’ 6”12’ 7”

6’ 4”8’ 5”10’ 6”12’ 7”

6’8’

10’12’

2’3’4’4’

31.717.911.47.9

5’ 6”7’ 2”8’ 11”10’ 9”

5’ 5”7’ 3”9’ 1”

10’ 11”

3’4’5’6’

3’4’6’7’

48.127

17.512.2

4’ 1”5’ 5”6’ 9”8’ 1”

5’ 3”6’ 10”8’ 7”10’ 2”

3’4’5’6’

2’3’3’4’

64.135

23.216

3’4’ 2”5’ 1”6’ 1”

3’ 2”4’ 3”5’ 2”6’ 3”

Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

WL

FC

D

50° Wide Flood (50)

38480°

70°

60°

L

W

CD

60°

L

W

D

C

30°

FC

D

LC W

30°

CCT / CRI Multipliers: 2700K / 82 CRI (x 0.96) 2700K / 92 CRI (x 0.8) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.83) 3500K / 82 CRI (x 1.03) 3500K / 92 CRI (x 0.86) 4100K / 82 CRI (x 1.04) 4100K / 92 CRI (x 0.89)

Emergency Multiplier: 7W Emergency (x 0.71)

JOB NAME

CATALOG NUMBER

NOTES TYPE

MB-MULTIPLES L/M-0515:19 P-23

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 3: ICL-MBSG2-4 JOB CATALOG MBS G2 Retractable Recessed Multiple … · MBS G2 Retractable Recessed Multiple (4) Head - Gen 2 ... Remote or integral test switch included. External battery

ICL-MBSG2L230-1Report #: ILL-08232016-03.2 (-16) ILL-08232016-02.2 (-24) ILL-08232016-01.2 (-32) ILL-08232016-05.2 (-50)

APPLICATION DATA:

W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

Photometric Data shown is compiled per head. For multi-light photometrics consult factory.

1049

1574

2099 10° 20°

Watts: 13.7Lumens: 1519 LPW: 111 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

209420401671120936448

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

116938845161762529221

2923

5847

8770

11693 10°

80°

70°

60°

50°

40°

30°20°

16° Spot (16)

Watts: 13.7Lumens: 1678 LPW: 123 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

42563804196590915817

1064

2128

3192

4256 10°

80°

70°

60°

50°

40°

30°20°

24° Narrow Flood (24)

Watts: 13.7Lumens: 1442 LPW: 105 CCT: 3000K

50°

40°

881

1763

2644

3525 10° 20°

32° Flood (32)

Watts: 13.7Lumens: 1478 LPW: 108 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

35253389207294019019

80°

70°

60°

50°

40°

30° 30°

0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL

D FC W L D C FC W L D C FC W L D C FC W L

ICL-MBSG2L230-1-163000K / 16° Spot

Per Head

6’8’

10’12’

32518311781.2

1’ 7”2’ 2”2’ 8”3’ 4”

1’ 7”2’ 2”2’ 8”3’ 4”

6’8’

10’12’

3’4’5’7’

20811774.852.2

2’ 4”2’ 11”3’ 8”4’ 4”

1’ 9”2’ 6”3’ 2”3’ 9”

3’4’5’6’

5’6’8’10’

29316410973.2

1’ 6”2’ 1”2’ 7”3’ 3”

3’ 1”4’

4’ 9”5’ 11”

3’4’5’6’

2’2’3’4’

437234176109

1’ 2”1’ 3”1’ 6”1’ 11”

1’ 3”1’ 11”1’ 8”2’ 5”

ICL-MBSG2L230-1-243000K / 24° Narrow Flood

Per Head

6’8’

10’12’

11866.542.629.6

3’4’5’6’

3’4’5’6’

6’8’

10’12’

3’4’5’6’

8045

28.820

3’ 8”4’ 10”

6’7’ 3”

3’ 4”4’ 4”5’ 4”6’ 5”

3’4’5’6’

4’6’7’9’

11164.140.928.5

2’ 9”3’ 6”4’ 4”5’ 3”

4’ 6”5’ 11”7’ 4”8’ 9”

3’4’5’6’

2’2’3’4’

17190.164.242.7

1’ 8”2’ 5”2’ 10”3’ 6”

1’ 10”2’ 8”3’ 1”3’ 9”

ICL-MBSG2L230-1-323000K / 32° Flood

Per Head

6’8’

10’12’

97.955.135.324.5

3’ 7”4’ 10”

6’7’ 4”

3’ 7”4’ 10”

6’7’ 4”

6’8’

10’12’

3’4’4’5’

68.538.525

17.4

4’ 2”5’ 7”6’ 11”8’ 2”

3’ 9”5’ 1”6’ 2”7’ 5”

3’4’5’6’

4’5’6’8’

10358.736.925.8

3’3’ 9”4’ 11”5’ 10”

4’ 8”6’ 1”7’ 8”9’ 2”

3’4’5’6’

2’3’3’4’

14677.553.136.6

2’2’ 11”3’ 4”

4’

2’ 4”3’ 1”3’ 8”4’ 5”

ICL-MBSG2L230-1-503000K / 50° Wide Flood

Per Head

6’8’

10’12’

58.232.720.914.5

6’ 4”8’ 5”10’ 6”12’ 7”

6’ 4”8’ 5”10’ 6”12’ 7”

6’8’

10’12’

2’3’4’4’

43.324.515.610.8

5’ 6”7’ 2”8’ 11”10’ 9”

5’ 5”7’ 3”9’ 1”

10’ 11”

3’4’5’6’

3’4’6’7’

65.736.923.916.6

4’ 1”5’ 5”6’ 9”8’ 1”

5’ 3”6’ 10”8’ 7”10’ 2”

3’4’5’6’

2’3’3’4’

87.647.831.821.9

3’4’ 2”5’ 1”6’ 1”

3’ 2”4’ 3”5’ 2”6’ 3”

Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

WL

FC

D

50° Wide Flood (50)

52580°

70°

60°

L

W

CD

60°

L

W

D

C

30°

FC

D

LC W

30°

CCT / CRI Multipliers: 2700K / 82 CRI (x 0.96) 2700K / 92 CRI (x 0.8) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.83) 3500K / 82 CRI (x 1.03) 3500K / 92 CRI (x 0.86) 4100K / 82 CRI (x 1.04) 4100K / 92 CRI (x 0.89)

Emergency Multiplier: 7W Emergency (x 0.51)

JOB NAME

CATALOG NUMBER

NOTES TYPE

MB-MULTIPLES L/M-0515:19 P-24

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 4: ICL-MBSG2-4 JOB CATALOG MBS G2 Retractable Recessed Multiple … · MBS G2 Retractable Recessed Multiple (4) Head - Gen 2 ... Remote or integral test switch included. External battery

ICL-MBSG2L330-1Report #: ILL-08232016-03.1 (-16) ILL-08232016-02.1 (-24) ILL-08232016-01.1 (-32) ILL-08232016-05.1 (-50)

APPLICATION DATA:

W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

Photometric Data shown is compiled per head. For multi-light photometrics consult factory.

1405

2108

2811 10° 20°

Watts: 20.2Lumens: 2034 LPW: 101 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

280427322238161948865

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

1566111846216683739228

4016

8031

12047

16062 10°

80°

70°

60°

50°

40°

30°20°

16° Spot (16)

Watts: 20.2Lumens: 2248 LPW: 111 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

584652252700124821724

1462

2923

4385

5846 10°

80°

70°

60°

50°

40°

30°20°

24° Narrow Flood (24)

Watts: 20.2Lumens: 1981 LPW: 98 CCT: 3000K

50°

40°

1211

2421

3632

4842 10° 20°

32° Flood (32)

Watts: 20.2Lumens: 2031 LPW: 101 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

484246552846129126126

80°

70°

60°

50°

40°

30° 30°

0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL

D FC W L D C FC W L D C FC W L D C FC W L

ICL-MBSG2L330-1-163000K / 16° Spot

Per Head

6’8’

10’12’

435245157109

1’ 7”2’ 2”2’ 8”3’ 4”

1’ 7”2’ 2”2’ 8”3’ 4”

6’8’

10’12’

3’4’5’7’

27815710070

2’ 4”2’ 11”3’ 8”4’ 4”

1’ 9”2’ 6”3’ 2”3’ 9”

3’4’5’6’

5’6’8’10’

39222014698.1

1’ 6”2’ 1”2’ 7”3’ 3”

3’ 1”4’

4’ 9”5’ 11”

3’4’5’6’

2’2’3’4’

585313235146

1’ 2”1’ 3”1’ 6”1’ 11”

1’ 3”1’ 11”1’ 8”2’ 5”

ICL-MBSG2L330-1-243000K / 24° Narrow Flood

Per Head

6’8’

10’12’

16291.358.540.6

3’4’5’6’

3’4’5’6’

6’8’

10’12’

3’4’5’6’

11061.839.627.5

3’ 8”4’ 10”

6’7’ 3”

3’ 4”4’ 4”5’ 4”6’ 5”

3’4’5’6’

4’6’7’9’

15288

56.239.1

2’ 9”3’ 6”4’ 4”5’ 3”

4’ 6”5’ 11”7’ 4”8’ 9”

3’4’5’6’

2’2’3’4’

23512488.258.7

1’ 8”2’ 5”2’ 10”3’ 6”

1’ 10”2’ 8”3’ 1”3’ 9”

ICL-MBSG2L330-1-323000K / 32° Flood

Per Head

6’8’

10’12’

13575.748.433.6

3’ 7”4’ 10”

6’7’ 4”

3’ 7”4’ 10”

6’7’ 4”

6’8’

10’12’

3’4’4’5’

9452.934.423.9

4’ 2”5’ 7”6’ 11”8’ 2”

3’ 9”5’ 1”6’ 2”7’ 5”

3’4’5’6’

4’5’6’8’

14280.750.735.5

3’3’ 9”4’ 11”5’ 10”

4’ 8”6’ 1”7’ 8”9’ 2”

3’4’5’6’

2’3’3’4’

20110772.950.3

2’2’ 11”3’ 4”

4’

2’ 4”3’ 1”3’ 8”4’ 5”

ICL-MBSG2L330-1-503000K / 50° Wide Flood

Per Head

6’8’

10’12’

77.943.828

19.5

6’ 4”8’ 5”10’ 6”12’ 7”

6’ 4”8’ 5”10’ 6”12’ 7”

6’8’

10’12’

2’3’4’4’

57.932.820.914.5

5’ 6”7’ 2”8’ 11”10’ 9”

5’ 5”7’ 3”9’ 1”

10’ 11”

3’4’5’6’

3’4’6’7’

87.949.532

22.3

4’ 1”5’ 5”6’ 9”8’ 1”

5’ 3”6’ 10”8’ 7”10’ 2”

3’4’5’6’

2’3’3’4’

11764

42.529.3

3’4’ 2”5’ 1”6’ 1”

3’ 2”4’ 3”5’ 2”6’ 3”

Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

WL

FC

D

50° Wide Flood (50)

70380°

70°

60°

L

W

CD

60°

L

W

D

C

30°

FC

D

LC W

30°

CCT / CRI Multipliers: 2700K / 82 CRI (x 0.96) 2700K / 92 CRI (x 0.8) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.83) 3500K / 82 CRI (x 1.03) 3500K / 92 CRI (x 0.86) 4100K / 82 CRI (x 1.04) 4100K / 92 CRI (x 0.89)

Emergency Multiplier: 7W Emergency (x 0.35)

JOB NAME

CATALOG NUMBER

NOTES TYPE

MB-MULTIPLES L/M-0515:19 P-25

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 5: ICL-MBSG2-4 JOB CATALOG MBS G2 Retractable Recessed Multiple … · MBS G2 Retractable Recessed Multiple (4) Head - Gen 2 ... Remote or integral test switch included. External battery

ICL-MBSG2L430-1Report #: ILL-08232016-03 (-16) ILL-08232016-02 (-24) ILL-08232016-01 (-32) ILL-08232016-05 (-50)

1874

2811

3748 10° 20°

Watts: 29.3Lumens: 2713 LPW: 93 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

373936432984215865186

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

20734157952888111652238

5220

10441

15661

20881 10°

80°

70°

60°

50°

40°

30°20°

16° Spot (16)

Watts: 29.3Lumens: 2997 LPW: 102 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

760067933510162328231

1900

3800

5700

7600 10°

80°

70°

60°

50°

40°

30°20°

24° Narrow Flood (24)

Watts: 29.3Lumens: 2575 LPW: 88 CCT: 3000K

50°

40°

1574

3148

4721

6295 10° 20°

32° Flood (32)

Watts: 29.3Lumens: 2640 LPW: 90 CCT: 3000K

Candelas at Nadir

Degree Candela

0°5°15°25°35°45°

629560513700167934034

80°

70°

60°

50°

40°

30° 30°

APPLICATION DATA:

W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.

W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles

Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.

50° Wide Flood (50)

93780°

70°

60°

0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL

D FC W L D C FC W L D C FC W L D C FC W L

ICL-MBSG2L430-1-163000K / 16° Spot

Per Head

6’8’

10’12’

580326209145

1’ 7”2’ 2”2’ 8”3’ 4”

1’ 7”2’ 2”2’ 8”3’ 4”

6’8’

10’12’

3’4’5’7’

37120913493.3

2’ 4”2’ 11”3’ 8”4’ 4”

1’ 9”2’ 6”3’ 2”3’ 9”

3’4’5’6’

5’6’8’10’

523293194131

1’ 6”2’ 1”2’ 7”3’ 3”

3’ 1”4’

4’ 9”5’ 11”

3’4’5’6’

2’2’3’4’

780417314195

1’ 2”1’ 3”1’ 6”1’ 11”

1’ 3”1’ 11”1’ 8”2’ 5”

ICL-MBSG2L430-1-243000K / 24° Narrow Flood

Per Head

6’8’

10’12’

21111976

52.8

3’4’5’6’

3’4’5’6’

6’8’

10’12’

3’4’5’6’

14380.451.535.7

3’ 8”4’ 10”

6’7’ 3”

3’ 4”4’ 4”5’ 4”6’ 5”

3’4’5’6’

4’6’7’9’

19811473.150.8

2’ 9”3’ 6”4’ 4”5’ 3”

4’ 6”5’ 11”7’ 4”8’ 9”

3’4’5’6’

2’2’3’4’

30516111576.3

1’ 8”2’ 5”2’ 10”3’ 6”

1’ 10”2’ 8”3’ 1”3’ 9”

ICL-MBSG2L430-1-323000K / 32° Flood

Per Head

6’8’

10’12’

17598.463

43.7

3’ 7”4’ 10”

6’7’ 4”

3’ 7”4’ 10”

6’7’ 4”

6’8’

10’12’

3’4’4’5’

12268.844.731.1

4’ 2”5’ 7”6’ 11”8’ 2”

3’ 9”5’ 1”6’ 2”7’ 5”

3’4’5’6’

4’5’6’8’

18510565.946.1

3’3’ 9”4’ 11”5’ 10”

4’ 8”6’ 1”7’ 8”9’ 2”

3’4’5’6’

2’3’3’4’

26113894.765.3

2’2’ 11”3’ 4”

4’

2’ 4”3’ 1”3’ 8”4’ 5”

ICL-MBSG2L430-1-503000K / 50° Wide Flood

Per Head

6’8’

10’12’

10458.437.426

6’ 4”8’ 5”10’ 6”12’ 7”

6’ 4”8’ 5”10’ 6”12’ 7”

6’8’

10’12’

2’3’4’4’

77.243.727.819.3

5’ 6”7’ 2”8’ 11”10’ 9”

5’ 5”7’ 3”9’ 1”

10’ 11”

3’4’5’6’

3’4’6’7’

11765.942.629.7

4’ 1”5’ 5”6’ 9”8’ 1”

5’ 3”6’ 10”8’ 7”10’ 2”

3’4’5’6’

2’3’3’4’

15785.356.739.1

3’4’ 2”5’ 1”6’ 1”

3’ 2”4’ 3”5’ 2”6’ 3”

WL

FC

DL

W

CD

60°

L

W

D

C

30°

FC

D

LC W

30°

Photometric Data shown is compiled per head. For multi-light photometrics consult factory.

CCT / CRI Multipliers: 2700K / 82 CRI (x 0.96) 2700K / 92 CRI (x 0.8) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.83) 3500K / 82 CRI (x 1.03) 3500K / 92 CRI (x 0.86) 4100K / 82 CRI (x 1.04) 4100K / 92 CRI (x 0.89)

Emergency Multiplier: 7W Emergency (x 0.24)

JOB NAME

CATALOG NUMBER

NOTES TYPE

MB-MULTIPLES L/M-0515:19 P-26

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.