Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated...

32
Hydraulic Quick Coupling Interchange Updated April 2009 (Rev. I) Through the years, SafeWay Hydraulics, Inc. has accumulated the inter- change information found within this booklet. Although we are reasonably confident that the information contained herein is accurate, we cannot accept any liability for errors. This interchange guide lists those products that interconnect due to dimen- sional integrity within an accepted interchange; it does not take into account substantial differences in product performance between brands, or specific features unique to a given brand. Product part numbers and specifications change frequently. Please contact our Customer Service Department if you have any questions regarding interchangeability and technical information. We strongly suggest that for the best possible performance and reliability, both coupling halves should be SafeWay. 4040 Norex Drive • Chaska, Minnesota 55318 U.S.A. Phone: (952) 466-6220 • Fax: (952) 466-6219 Toll Free: (800) 222-1169 E-mail Address: [email protected] See us on the Internet: www.safewayhyd.com

Transcript of Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated...

Page 1: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Hydraulic Quick CouplingInterchange

Updated April 2009 (Rev. I)

Through the years, SafeWay Hydraulics, Inc. has accumulated the inter-change information found within this booklet. Although we are reasonablyconfident that the information contained herein is accurate, we cannotaccept any liability for errors.

This interchange guide lists those products that interconnect due to dimen-sional integrity within an accepted interchange; it does not take into accountsubstantial differences in product performance between brands, or specificfeatures unique to a given brand. Product part numbers and specificationschange frequently. Please contact our Customer Service Department if youhave any questions regarding interchangeability and technical information.

We strongly suggest that for the best possible performance and reliability,both coupling halves should be SafeWay.

4040 Norex Drive • Chaska, Minnesota 55318 U.S.A.Phone: (952) 466-6220 • Fax: (952) 466-6219

Toll Free: (800) 222-1169E-mail Address: [email protected] See us on the Internet: www.safewayhyd.com

Page 2: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

W A R N I N G S T A T E M E N T

S A F E T Y G U I D E — Q U I C K A C T I O N C O U P L I N G S

SafeWay Hydraulics, Inc.

WARNING

FAILURE, IMPROPER USE OR IMPROPER SELECTION OF THE SYSTEMS AND/OR COMPONENTS DESCRIBED HERE-IN MAY CAUSE DEATH, PERSONAL INJURY AND/OR PROPERTY DAMAGE.

This document, as well as all other catalogs, price lists and information provided by SafeWay Hydraulics, Inc., its subsidiaries or authorizeddistributors, is intended to provide product information and/or system options for further consideration by users having substantial techni-cal expertise. It is imperative that all aspects of any intended use be analyzed and all pertinent information reviewed concerning the component or system in a current product catalog. Due to the variety of operating conditions and applications for these components andsystems, the user, through its own analysis, testing and evaluation, is solely responsible for making the final selection of the products andsystems and ensuring that all safety, warning and performance requirements of the application or use are met.

The components described herein, including without limitation, all component features, specifications, designs, pricing and availability, aresubject to change at any time at the sole discretion of SafeWay Hydraulics, Inc. and its subsidiaries at any time without notice.

1. QUICK COUPLINGS CAN FAIL WITHOUT WARNING FOR AVARIETY OF REASONS. ALL EQUIPMENT AND SYSTEMSSHOULD BE OF A FAIL-SAFE DESIGN TO AVOID ENDANGER-ING PERSONS AND PROPERTY.

2. ANY PERSON RESPONSIBLE FOR SELECTING OR USINGQUICK COUPLINGS SHOULD READ AND UNDERSTAND THISSAFETY GUIDE AND HAVE A GOOD UNDERSTANDING OFFLUID SYSTEM DESIGN AND MAINTENANCE.

3. SAFEWAY, ITS REPRESENTATIVES AND DISTRIBUTORS DONOT REPRESENT OR WARRANT THAT ANY QUICK COU-PLING IS SUITABLE FOR ANY SPECIFIC USE. THE USER,THROUGH ITS OWN TESTING AND EVALUATION, IS SOLELYRESPONSIBLE FOR FINAL SELECTION OF THE PRODUCTSAND SYSTEMS AND ENSURING THAT ALL SAFETY, WARN-ING AND PERFORMANCE REQUIREMENTS OF THE APPLI-CATION OR USE ARE MET.

Coupler InstallationQuick couplings should be located so as not to expose the operator tomoving parts, hot parts, the potential of falling, slipping, or other haz-ardous conditions. Precautions should be taken to not over tightenmating threaded parts during installation.

Locking MechanismBall locking quick couplings can unintentionally disconnect if they aredragged over obstructions while on the end of a hose, or if the sleeveis bumped or moved enough to cause disconnect. Sleeves designedwith flanges, to provide better gripping for gloved hands, are especiallysusceptible to accidental disconnect and should not be used wherethese conditions exist. THE SLEEVE LOCK OPTION SHOULD BECONSIDERED WHERE THERE IS A POTENTIAL FOR UNINTENDEDUNCOUPLING.

Thread connection must be fully connected prior to pressurization.Pressure ratings must apply to full connected or fully disconnectedquick couplings. IF USING A CONNECT-UNDER-PRESSURE STYLETHREADED CONNECTION QUICK COUPLING, ADHERE TO THESPECIFIED MAXIMUM PRESSURE RATING FOR CONNECTION-UNDER-PRESSURE (usually less than 10% of the maximum operatingpressure).

Coupler SizeTransmission of power by means of pressurized fluid varies with the sys-tem pressure and flow rate. The body size of the coupler must be ade-

quate to keep pressure loss to a minimum to avoid damage due to heatgeneration or excessive fluid velocity.

Mechanical LoadsExcessive axial and side forces or vibration can reduce coupler life orcause failure.

PressureWhen selecting your quick coupling, make sure its maximum operatingpressure is equal to, or greater than, the maximum possible systempressure. DO NOT EXCEED THE LIMITS OF THE COUPLER. Pressureimpulse can shorten the life of a coupler.

Hose WhipA short length of hose between the tool and the coupler half should beused instead of a rigid mount. This reduces the potential for couplerdamage and provides some isolation from mechanical vibration whichcould cause accidental uncoupling. Never try to connect or disconnectthe coupler when there is pressure in the system unless you are using aquick coupling designed for that purpose.

EnvironmentEnvironmental conditions including, but not limited to, moisture, water,chemicals, ozone, ultraviolet radiation and air pollutants can causedegradation of coupling components and premature quick coupling fail-ure. Choose the proper body material for use in the environment the inwhich system is placed.

VacuumNot all quick couplings are suitable or recommended for vacuum serv-ice. Quick couplings used in vacuum applications must be selected toensure that the quick coupling will withstand the vacuum and pressureof the system.

Fluid and TemperatureQuick coupling body and seal materials must be compatible with themedia and ambient temperature, both steady and transient. DO NOTEXCEED THE LIMITS OF THE COUPLER.

Fluid LeaksDO NOT GO NEAR FLUID LEAKS. High pressure leaks of fluid such asoil easily puncture skin and can cause serious injury, gangrene or death.Relieve pressure before loosening fittings. Do not use fingers or skin tocheck for leaks. If injured, seek emergency medical help. Immediatesurgery is required to remove oil.

!

Page 3: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

T A B L E O F C O N T E N T S

Aeroquip (Eaton) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 3CEJN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Dayco . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Dixon (Perfecting) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 - 6DynaQuip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 - 7FASTER® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 - 9Foster® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9Gates® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10Goodyear® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 - 12Hansen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 - 14HOFMANN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 - 15HOLMBURY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 - 16Intertraco . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 - 17Parker / Pioneer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 - 20Snap-Tite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 - 22Stucchi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 - 23TEMA (Rectus) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24TOMCO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 - 26

ORIGINAL EQUIPMENT MANUFACTURERS

Allis-Chalmers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Enerpac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Ford® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Case IH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27John Deere® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27Melroe (Bobcat) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28New Holland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28Power Team® (SPX Fluid Power) . . . . . . . . . . . . . . . . . . . . . . . .28Skid Steer Loader & Attachments . . . . . . . . . . . . . . . . . . . . . .29

Page 4: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Aeroquip (Eaton)

Aeroquip SafeWay Aeroquip SafeWay150-22-12 S512-6 5602-8-10S S561-4150-22-16 S512-8 5602-8-10S S71-4P5100-S2-12B S511-6 5603 S42-45100-S2-16B S511-8 5606-10-10S S56-4-105100-S2-16B S511-8-STL 5606-12-12S S56-6-125100-S2-20B S511-10 5606-16-16S S56-8-165100-S2-20B S511-10-STL 5606-6-6S S56-3-65100-S5-12B S515W-6 5606-8-10S S56-4-85100-S5-16B S515W-8 5608-10-10S S565-4-105100-S5-16B S515W-8-STL 5608-12-12S S565-6-125100-S5-20B S515W-10 5608-16-16S S565-8-165100-S5-20B S515W-10-STL 5608-6-6S S565-3-65100-S7-12S S519-6 5608-8-10S S565-4-85100-S7-16S S519-8 5610-10-10S S561-4-105100-S7-20S S519-10 5610-12-12S S561-6-125100-S9-12S S514-6 5610-16-16S S561-8-165100-S9-16S S514-8 5610-6-6S S561-3-65100-S9-20S S514-10 5610-8-10S S561-4-85101-12B S51W-6 5657-10 S59-45101-16B S51W-8 5657-12 S59-65101-16B S51W-8-STL 5657-16 S59-85101-20B S51W-10 5657-4 S59-25101-20B S51W-10-STL 5657-6 S59-35110-S5-12B S515H-6 5659-10 S54-45110-S5-16B S515H-8 5659-12 S54-65110-S5-16B S515H-8-STL 5659-16 S54-85110-S5-20B S515H-10 5659-4 S54-25110-S5-20B S515H-10-STL 5659-6 S54-35111-12B S51H-6 FD41-1000-04-04 S805-25111-16B S51H-8 FD41-1013-04-04 S801-2F5111-16B S51H-8-STL FD41-1014-04-04 S801-2M5111-20B S51H-10 FD42-1000-04-04 S20A-2P5111-20B S51H-10-STL FD42-1001-04-04 S25A-2P5600-12-12S S56-6 FD42-1002-04-04 S41-2P5600-16-16S S56-8 FD43-1001-04-04 S825-25600-4-4S S56-2 FD43-1001-06-06 S825-35600-6-6S S56-3 FD43-1011-04-04 S825-3M5600-8-10S S56-4 FD44-1002-08-10 S12-45600-8-10S S20-4P FD45-1000-02-02 S10-15601-12-12S S565-6 FD45-1000-04-04 S10-25601-16-16S S565-8 FD45-1000-06-06 S10-35601-4-4S S565-2 FD45-1000-08-10 S10-45601-6-6S S565-3 FD45-1000-12-12 S10-65601-8-10S S565-4 FD45-1000-16-16 S10-85601-8-10S S25-4P FD45-1001-02-02 SS10-15602-12-12S S561-6 FD45-1001-04-04 SS10-25602-16-16S S561-8 FD45-1001-06-06 SS10-35602-4-4S S561-2 FD45-1001-08-10 SS10-45602-6-6S S561-3 FD45-1001-12-12 SS10-6

SafeWay Hydraulics, Inc. cross ref., rev.i Page 1

Page 5: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Aeroquip (continued)

Aeroquip SafeWay Aeroquip SafeWayFD45-1001-16-16 SS10-8 FD45-1101-06-06 BS105-3FD45-1002-02-02 S101-1 FD45-1101-08-10 BS105-4FD45-1002-04-04 S101-2 FD45-1101-12-12 BS105-6FD45-1002-06-06 S101-3 FD45-1101-16-16 BS105-8FD45-1002-08-10 S101-4 FD48-1000-04-04 SH20-2PFD45-1002-12-12 S101-6 FD48-1001-04-04 SH25-2PFD45-1002-16-16 S101-8 FD48-1002-04-04 SH21-2PFD45-1003-02-02 S105-1 FD49-1000-06-06 FF49-3FD45-1003-04-04 S105-2 FD49-1000-08-06 FF49-4FD45-1003-06-06 S105-3 FD49-1001-06-06 FF495-3FD45-1003-08-10 S105-4 FD49-1001-08-06 FF495-4FD45-1003-12-12 S105-6 FD49-1002-06-06 FF491-3FD45-1003-16-16 S105-8 FD49-1002-08-06 FF491-4FD45-1004-02-02 SS101-1 FD49-1004-08-06 FF491-3-8FD45-1004-04-04 SS101-2 FD49-1005-08-06 FF495-3-8FD45-1004-06-06 SS101-3 FD49-1056-08-06 FF49-3-8FD45-1004-08-10 SS101-4 FD56-1037-08-10 S561-4FD45-1004-12-12 SS101-6 FD56-1062-04-04S S561-2FFD45-1004-16-16 SS101-8 FD56-1062-06-06S S561-3FFD45-1005-02-02 SS105-1 FD56-1062-08-10S S561-4FFD45-1005-04-04 SS105-2 FD56-1062-12-12S S561-6FFD45-1005-06-06 SS105-3 FD56-1062-16-16S S561-8FFD45-1005-08-10 SS105-4 FD56-1064-04-04S S565-2FFD45-1005-12-12 SS105-6 FD56-1064-06-06S S565-3FFD45-1005-16-16 SS105-8 FD56-1064-08-10S S565-4FFD45-1040-04 S19-2 FD56-1064-12-12S S565-6FFD45-1040-06 S19-3 FD56-1064-16-16S S565-8FFD45-1040-10 S19-4 FD56-1065-04-04S S56-2FFD45-1040-12 S19-6 FD56-1065-06-06S S56-3FFD45-1040-16 S19-8 FD56-1065-08-10S S56-4FFD45-1041-04 S14-2 FD56-1065-12-12S S56-6FFD45-1041-06 S14-3 FD56-1065-16-16S S56-8FFD45-1041-10 S14-4 FD56-1072-08-10 S561-4-8FFD45-1041-12 S14-6 FD56-1072-12-12 S561-6-12FFD45-1041-16 S14-8 FD56-1074-08-10 S565-4-8FFD45-1086-02-02 BS101-1 FD56-1074-12-12 S565-6-12FFD45-1086-04-04 BS101-2 FD56-1075-06-06S S56-3-6FD45-1086-06-06 BS101-3 FD56-1075-08-10S S56-4-8FD45-1086-08-10 BS101-4 FD56-1075-12-10S S56-4-10FD45-1086-12-12 BS101-6 FD56-1075-12-12S S56-6-12FD45-1086-16-16 BS101-8 FD56-1075-16-16S S56-8-16FD45-1100-02-02 BS10-1 FD56-1225-08-10 S565-4FD45-1100-04-04 BS10-2 FD70-1010-08-10 S11-15FD45-1100-06-06 BS10-3 FD71-1000-08-10 S40-4PFD45-1100-08-10 BS10-4 FD71-1001-08-10 S45-4PFD45-1100-12-12 BS10-6 FD72-1000-08-10 S70-4PFD45-1100-16-16 BS10-8 FD72-1001-08-10 S75-4FD45-1101-02-02 BS105-1 FD76-1002-08-10 S71-4PFD45-1101-04-04 BS105-2

SafeWay Hydraulics, Inc. cross ref., rev.i Page 2

Page 6: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Aeroquip (continued)

Aeroquip SafeWay Aeroquip SafeWayFD76-1010-08-10 S71-15P FD89-1002-12-08 FFE491-4-3/4FD76-1024-08-10 S71-4 FD89-1001-16-16 FFE495-8FD76-1050-08-10 S71-15 FD89-1002-16-16 FFE491-8FD89-1001-04-04 FFE495-2 FD89-1004-08-06 FF491-3-8FD89-1002-04-04 FFE491-2 FD89-1004-10-08 FFE491-4-10FD89-1001-06-06 FF495-3 FD89-1004-12-08 FFE491-4-12FD89-1002-06-06 FF491-3 FD89-1004-16-16 FFE491-6-16FD89-1001-08-06 FF495-4 FD89-1005-08-06 FF495-3-8FD89-1002-08-06 FF491-4 FD89-1005-10-08 FFE495-4-10FD89-1001-08-08 FFE495-4 FD89-1005-12-08 FFE495-4-12FD89-1002-08-08 FFE491-4 FD89-1005-16-16 FFE495-6-16FD89-1001-12-08 FFE495-4-3/4

CEJN

CEJN SafeWay CEJN SafeWay10 230 1452 S35-2P 10 495 6404 S561-310 230 1484 S35-3P 10 565 1405 FFE495-410 230 6402 S31-2P 10 565 6405 FFE491-410 230 6434 S31-3P 10 575 1405 S105-410 265 1402 FFE495-2 10 575 6405 S101-410 265 6402 FFE491-2 10 595 1405 S565-410 310 1402 S825-2 10 595 6405 S561-410 310 1404 S825-3 10 665 1401 FFE495-610 310 1452 S825-2M 10 665 6401 FFE491-610 310 5402 S821-2F 10 675 1401 S105-610 310 5404 S821-3F 10 675 6401 S101-610 365 1404 FF495-3 10 695 1401 S565-610 365 6404 FF491-3 10 695 6401 S561-610 375 1402 S105-2 10 765 1403 FFE495-810 375 6402 S101-2 10 765 6403 FFE491-810 395 1402 S565-2 10 775 1403 S105-810 395 6402 S561-2 10 775 6403 S101-810 475 1404 S105-3 10 795 1403 S565-810 475 6404 S101-3 10 795 6403 S561-810 495 1404 S565-3

SafeWay Hydraulics, Inc. cross ref., rev.i Page 3

Page 7: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Dayco

Dayco SafeWay Dayco SafeWayQD1-4 S10-2 QD75-8 S75-4QD1-6 S10-3 QDA25-8-1 S25-4-1QD1-8 S10-4 QDA25-8-2 S25-4-2QD1-12 S10-6 QDA25-8-3 S25-4-3QD1-16 S10-8 QDFF491-4 FF491-4QD2-12 S20-15 QDFF495-4 FF49-4QD2F-12 S20F-6 QDM11-8 S11-4QD3-4 S30-2P QDM11-12 S11-15QD3-6 S30-3P QDM12-8 S12-4QD4-4 S40-2 QDM12-14 S12-16QD4-6 S40-3 QDM71-8P S71-4PQD4-8 S40-4 QDM71-8 S71-4QD4-12 S40-6 QDM71-15 S71-15QD7-8 S70-4 QDS51-4 S561-4QD11-4 S101-2 QDS56-4 S565-4QD11-6 S101-3 123959 S40-2QD11-8 S101-4 123960 S40-3QD11-12 S101-6 123961 S40-4QD11-16 S101-8 123962 S40-6QD15-4 S105-2 123963 S70-4QD15-6 S105-3 123985 S41-2QD15-8 S105-4 123986 S41-3QD15-12 S105-6 123987 S71-4QD15-16 S105-8 123988 S71-6QD21F-12 S21F-6 123991 S44-4QD25F-12 S25F-6 123992 S45-2QD25-12 S25-15 123993 S45-3QD31-4 S31-2P 123994 S45-4QD31-6 S31-3P 123995 S45-6QD34-6 S34-3 123997 S49-4QD35-4 S35-2P 124001 S11-4QD35-6 S35-3P 124002 S11-15QD39-6 S39-3 124003A S12-16QD41-4 S41-2 124003 S12-4QD41-6 S41-3 124004 S71-4PQD41-8 S71-4 124006 S71-15QD41-12 S71-6 124009 FF491-4QD42-8 S42-4 124010 FF495-4QD44-8 S44-4 124011 S561-4QD45-4 S45-2 124012 S565-4QD45-6 S45-3 124013 S25-4-3QD45-8 S45-4 124600 S54-4QD45-12 S45-6 124601 S59-4QD49-8 S49-4

SafeWay Hydraulics, Inc. cross ref., rev.i Page 4

Page 8: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Dixon (Perfecting)

Dixon SafeWay Dixon SafeWay1H1F1S SS105-1 4KOF4 S565-4-81HF1 S105-1 4KOF5 S565-4-101HF1B BS105-1 4R-DP S44-42FF2-B S825-2 4RF4 S25-42FM2-B S825-2M 6H-DP S14-62H-DP S14-2 6HF6 S105-62HF2 S105-2 6HF6B BS105-62HF2B BS105-2 6HF6S SS105-62HF2S SS105-2 6HTF6 FFE495-62K-DP S54-2 6HTOF8 FFE495-6-162KF2 S565-2 6K-DP S54-62MF2 S805-2 6KF6 S565-62R-DP S44-2 6KOF6 S565-6-122RF2-PV S25A-2P 6WF6-B S515W-62T16 S34-2 6WF6-B-HN S515H-62T17M2 S35-2P 8H-DP S14-82T17M2-T2F2D S30-2P 8HF8 S105-82T-DP S34-2 8HF8B BS105-82TM2 S35-2P 8HF8S SS105-83H-DP S14-3 8HTF8 FFE495-83HF3 S105-3 8HTOF8 FFE495-8-203HF3B BS105-3 8K-DP S54-83HF3S SS105-3 8KF8 S565-83HGF3 FF495-3 8WF8-B S515W-83HTBF3-SS SF495-3 8WF8-B S515W-8-STL3HTF3 FF495-3 8WF8-B-HN S515H-83HTF4 FF495-4 8WF8-B-HN S515H-8-STL3HTO4 FF495-3-8 10WF10-B S515W-103K-DP S54-3 10WF10-B S515W-10-STL3KF3 S565-3 10WF10-B-HN S515H-103KOF3 S565-3-6 D2F2-B S821-2F3T16 S34-3 D2M2-B S821-2M3T17M3 S35-3P D3F2 S821-3-2F3T17M3-T3F3D S30-3P D3F3-B S821-3F3T-DP S34-3 D3M2-B S821-3-2M3TM3 S35-3P D3M3-B S821-3M4GTF6 FFE495-4-3/4 H1F1 S101-14H-DP S14-4 H1F1B BS101-14HF4 S105-4 H1F1S SS101-14HF4B BS105-4 H2-DC S19-24HF4S SS105-4 H2F2 S101-24HTF4 FFE495-4 H2F2B BS101-24HTF6 FF495-6 H2F2S SS101-24HTOF5 FFE495-4-10 H3-DC S19-34HTOF6 FF495-6-12 H3F3 S101-34HTOF6 FFE495-4-12 H3F3B BS101-34K-DP S54-4 H3F3S SS101-34KF4 S565-4 H4-DC S19-4

SafeWay Hydraulics, Inc. cross ref., rev.i Page 5

Page 9: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Dixon (Perfecting) (continued)

Dixon SafeWay Dixon SafeWayH4F4 S101-4 K4F4 S561-4H4F4B BS101-4 K4OF4 S561-4-8H4F4S SS101-4 K4OF5 S561-4-10H6-DC S19-6 K6-DC S56-6H6F6 S101-6 K6F6 S561-6H6F6B BS101-6 K6OF6 S561-6-12H6F6S SS101-6 K8-DC S59-8H8-DC S19-8 K8F8 S561-8H8F8 S101-8 M2F2 S801-2FH8F8B BS101-8 M2M2 S801-2MH8F8S SS101-8 R2-DC S49-2HT3F3 FF491-3 R2F2-PV S41-2PHT3F3-SS SF491-3 R4-DC S49-4HT3F4 FF491-4 R4F4 S71-4HT3OF4 FF491-3-8 T216 S39-2HT3OF5 FFE491-4-10 T2-DC S39-2HT4F4 FFE491-4 T2F2 S31-2PHT4F6 FF491-6 T2F2D S31-2PHT4F6 FFE491-4-3/4 T316 S39-3HT4OF6 FF491-6-12 T3-DC S39-3HT4OF6 FFE491-4-12 T3F3 S31-3PHT6F6 FFE491-6 T3F3D S31-3PHT6OF8 FFE491-6-16 W10-BMF S512-10HT8F8 FFE491-8 W1F10-B S511-10-STLHT8OF8 FFE491-8-20 W1F10-B S511-10K2-DC S59-2 W6-BMF S512-6K2F2 S561-2 W6F6-B S511-6K3-DC S59-3 W8-BMF S512-8K3F3 S561-3 W8F8-B S511-8K3OF3 S561-3-6 W8F8-B S511-8-STLK4-DC S59-4

DynaQuip®

DynaQuip SafeWay DynaQuip SafeWayDHP-12120 S101-6 DHS-440 S105-2DHP-12120B BS101-6 DHS-440B BS105-2DHP-16160 S101-8 DHS-660 S105-3DHP-16160B BS101-8 DHS-660B BS105-3DHP-440 S101-2 DHS-880 S105-4DHP-440B BS101-2 DHS-880B BS105-4DHP-660 S101-3 DM-240 S805-2DHP-660B BS101-3 P-240 S801-2FDHP-880 S101-4 P-241 S801-2MDHP-880B BS101-4 PDC-120 S19-6

SafeWay Hydraulics, Inc. cross ref., rev.i Page 6

Page 10: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

DynaQuip® (continued)

DynaQuip SafeWay DynaQuip SafeWayPDC-160 S19-8 SDC-160 S14-8PDC-40 S19-2 SDC-40 S14-2PDC-60 S19-3 SDC-60 S14-3PDC-80 S19-4 SDC-80 S14-4SDC-120 S14-6

FASTER (Italia)

FASTER SafeWay FASTER SafeWay2FFI-12-34NPT-F FFE495-4-3/4 ANV-34-NPT-M S561-62FFI-12-34NPT-M FFE491-4-3/4 ANV-38-38SAE-F S565-3-62FFI-12-34SAE-F FFE495-4-12 ANV-38-38SAE-M S561-3-62FFI-12-34SAE-M FFE491-4-12 ANV-38-NPT-F S565-32FFI-12-58SAE-F FFE495-4-10 ANV-38-NPT-M S561-32FFI-12-58SAE-M FFE491-4-10 CNV-08-14/SAE-F S45-15P2FFI-12-NPT-F FFE495-4 FB-12/34-NPT-F-5 S515W-62FFI-12-NPT-M FFE491-4 FB-12/34-NPT-M-5 S511-62FFI-14-NPT-F FFE495-2 FB-12-FL S512-62FFI-14-NPT-M FFE491-2 FB-16/1-NPT-F-5 S515W-8-STL2FFI-1-NPT-F FFE495-8 FB-16/1-NPT-F-5 S515W-82FFI-1-NPT-M FFE491-8 FB-16/1-NPT-M-5 S511-82FFI-34-1NPT-F FFE495-6-1 FB-16/1-NPT-M-5 S511-8-STL2FFI-34-1NPT-M FFE491-6-1 FB-16-FL S512-82FFI-34-1SAE-F FFE495-6-16 FB-20/114-NPT-F-5 S515W-102FFI-34-1SAE-M FFE491-6-16 FB-20/114-NPT-F-5 S515W-10-STL2FFI-34-NPT-F FFE495-6 FB-20/114-NPT-M-5 S511-102FFI-34-NPT-M FFE491-6 FB-20/114-NPT-M-5 S511-10-STL2FFN-38-12NPT-F FF495-4 FB-20-FL S512-102FFN-38-12NPT-MU FF491-4 FFN-38-NPT-MU FF491-32FFN-38-12SAE-F FF495-3-8 HNV-12-NPT-F S105-42FFN-38-12SAE-M FF491-3-8 HNV-12-NPT-F-2 SS105-42FFN-38-NPT-F FF495-3 HNV-12-NPT-F-5 BS105-42FFN-38-NPT-F2 SF495-3 (303 SS) HNV-12-NPT-M S101-42FFN-38-NPT-M2 SF491-3 (303 SS) HNV-12-NPT-M-2 SS101-42MV-34-NPT-M S71-6P HNV-12-NPT-M-5 BS101-42NV-12-12SAE-M S71-15P HNV-14-NPT-F S105-22NV-12-58SAE-M S71-16P HNV-14-NPT-F-2 SS105-22NV-12-NPT-M S71-4P HNV-14-NPT-F-5 BS105-2ANV-12-NPT-F S565-4 HNV-14-NPT-M S101-2ANV-12-NPT-M S561-4 HNV-14-NPT-M-2 SS101-2ANV-14-NPT-F S565-2 HNV-14-NPT-M-5 BS101-2ANV-14-NPT-M S561-2 HNV-18-NPT-F S105-1ANV-1-NPT-F S565-8 HNV-18-NPT-F-2 SS105-1ANV-1-NPT-M S561-8 HNV-18-NPT-F-5 BS105-1ANV-34-NPT-F S565-6 HNV-18-NPT-F-5 BS105-1

SafeWay Hydraulics, Inc. cross ref., rev.i Page 7

Page 11: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

FASTER (Italia) (continued)

FASTER SafeWay FASTER SafeWayHNV-18-NPT-M S101-1 NV-1-NPT-F S25-8PHNV-18-NPT-M S101-1 NV-1-NPT-M S21-8PHNV-18-NPT-M-2 SS101-1 NV-34-UNF-F S25-15PHNV-18-NPT-M-5 BS101-1 NV-34-UNF-F S45-15PHNV-18-NPT-M-5 BS101-1 NV-34-UNF-M S71-15PHNV-1-NPT-F S105-8 NV-38-NPT-F S45-3P & S25-3PHNV-1-NPT-F-2 SS105-8 NV-38-NPT-M S41-3PHNV-1-NPT-F-5 BS105-8 NV-78-UNF-F S25-16PHNV-1-NPT-M S101-8 NV-78-UNF-M S71-16PHNV-1-NPT-M-2 SS101-8 NVP-34-NPT-F S25F-6HNV-1-NPT-M-5 BS101-8 NVP-34-NPT-M S21F-6HNV-34-NPT-F S105-6 PS-12-NPT-F S75-4HNV-34-NPT-F-2 SS105-6 PV-12-NPT-F S45-4PHNV-34-NPT-F-5 BS105-6 PV-12-UNF-F S75-15HNV-34-NPT-M S101-6 PVVM-1/14-NPT-F S35-2PHNV-34-NPT-M-2 SS101-6 PVVM-1/38-NPT-F S35-3PHNV-34-NPT-M-5 BS101-6 PVVM-14-NPT-M S31-2PHNV-38-NPT-F S105-3 PVVM-38-NPT-M S31-3PHNV-38-NPT-F-2 SS105-3 TF-12 S49-4HNV-38-NPT-F-5 BS105-3 TF-14 S49-2HNV-38-NPT-M S101-3 TF-38 S49-3HNV-38-NPT-M-2 SS101-3 TFA-1 or TFA-1S S59-8MV-34-NPT-F S25-8P TFA-12S S59-4NS-12/78SAE-M S71-16 TFA-14 or TFA-14S S59-2NS-12-NPT-F S45-4 TFA-34 or TFA-34S S59-6NS-12-NPT-M S71-4 TFA-38 or TFA-38S S59-3NS-14-NPT-F S25A-2 TFF-38 or TFF-38-S FF494-3NS-14-NPT-M S41-2 TFH-1 or TFH-1-S S19-8NS-34-NPT-F S25F-6 TFH-12 or TFH-12-S S19-4NS-34-NPT-F S45-6 TFH-14 or TFH-14-S S19-2NS-34-NPT-M S71-6 TFH-18 or TFH-18-S S19-1NS-34-NPT-M S21F-6 TFH-34 or TFH-34-S S19-6NS-34-UNF-F S25-15 TFH-38 or TFH-38-S S19-3NS-34-UNF-M S71-15 TFP-14-S S39-2NS-38-NPT-F S45-3 TFV-38 or TFP-38-S S39-3NS-38-NPT-M S41-3 TM-12 S44-4NS-78-UNF-F S25-16 TM-14 S44-2NS-78-UNF-M S71-16 TM-38 S44-3NV-12-12SAE-F S565-4-8 TMA-1 or TMA-1-S S54-8NV-12-12SAE-M S561-4-8 TMA-12 or TMA-12-S S54-4NV-12-58SAE-F S25-16P TMA-14 or TMA-14-S S54-2NV-12-58SAE-F S565-4-10 TMA-34 or TMA-34-S S54-6NV-12-58SAE-M S561-4-10 TMA-38 or TMA-38-S S54-3NV-12-NPT-F S565-4 & S25-4P TMF-38 or TMF-38-S FF499-3NV-12-NPT-M S561-4 TMH-1 or TMH-1-S S14-8NV-12-NPT-M S71-4P TMH-12 or TMH-12-S S14-4NV-14-NPT-F S25A-2P TMH-14 or TMH-14-S S14-2NV-14-NPT-M S41-2P TMH-18 or TMH-18-S S14-1

SafeWay Hydraulics, Inc. cross ref., rev.i Page 8

Page 12: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

FASTER (Italia) (continued)

FASTER SafeWay FASTER SafeWayTMH-34 or TMH-34-S S14-6TMH-38 or TMH-38-S S14-3

Foster®

Foster SafeWay Foster SafeWay10-3 S821-2M H6DP S14-611-3 S821-2F H6S S105-6210-10 S801-2M H6S/S SS105-6210-11 S801-2F H6S12 S105-6-12210-3003 S805-2 H8B BS105-83003 S825-2 H8DP S14-83103 S825-2M H8S S105-840-4 S821-3-2M H8S/S SS105-841-4 S821-3-2F H8S16 S105-8-1642-4 S821-3M K1B BS101-14204 S825-3 K1S S101-143-4 S821-3F K1S/S SS101-14304 S825-3M K2B BS101-2H1B BS105-1 K2S S101-2H1S S105-1 K2S/S SS101-2H1S/S SS105-1 K2S6 S101-2-6H2B BS105-2 K3B BS101-3H2DP S14-2 K3S S101-3H2S S105-2 K3S/S SS101-3H2S/S SS105-2 K3S8 S101-3-8H2S6 S105-2-6 K4B BS101-4H3B BS105-3 K4S S101-4H3DP S14-3 K4S/S SS101-4H3S S105-3 K4S10 S101-4-10H3S/S SS105-3 K6B BS101-6H3S8 S105-3-8 K6S S101-6H4B BS105-4 K6S/S SS101-6H4DP S14-4 K6S12 S101-6-12H4S S105-4 K8B BS101-8H4S/S SS105-4 K8S S101-8H4S10 S105-4-10 K8S/S SS101-8H6B BS105-6 K8S16 S101-8-16

SafeWay Hydraulics, Inc. cross ref., rev.i Page 9

Page 13: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Gates

Gates SafeWay Gates SafeWayG94011-0404 S41-2 G94521-0404 S105-2G94011-0606 S41-3 G94521-0606 S105-3G94011-0808 S71-4 G94521-0808 S105-4G94011-0812 S71-6 G94521-1212 S105-6G94011-1212 S21F-6 G94521-1616 S105-8G94012-0808 S71-15 G94911-0606 FF491-3G94021-0404 S25A-2 G94911-0608 FF491-4G94021-0606 S25-3 G94912-0608 FF491-3-8G94021-0808 S25-4 G94921-0606 FF495-3G94021-0808D S45-4 G94921-0608 FF495-4G94021-0812D S45-6 G94922-0608 FF495-3-8G94021-1212 S25F-6 G95111-1212 S511-6G94022-0808 S25-15 G95111-1616 S511-8G94080-0004 S44-2 G95111-2020 S511-10G94080-0006 S44-3 G95121-1212 S515W-6G94080-0008 S44-4 G95121-1616 S515W-8G94090-0004 S49-2 G95121-2020 S515W-10G94090-0006 S49-3 G95611-0404 S561-2G94090-0008 S49-4 G95611-0606 S561-3G94111-0404 S41-2P G95611-0808 S561-4G94111-0606 S41-3P G95611-1212 S561-6G94111-0808 S71-4P G95611-1616 S561-8G94121-0404 S25A-2P G95621-0404 S565-2G94121-0606 S25-3P G95621-0606 S565-3G94121-0808 S25-4P G95621-0808 S565-4G94211-0808 S11-4 G95621-1212 S565-6G94212-0808 S11-15 G95621-1616 S565-8G94221-0808 S25-4-20 G95961-0808 S25-4-1G94311-0808 S12-4 G95962-0808 S25-4-3G94411-0808 S13-4 G95963-0808 S25-4-4G94511-0404 S101-2 G95964-0808 S25-4-2G94511-0606 S101-3 G95965-0808 S25-4-7G94511-0808 S101-4 G95966-0808 S25-4-3DG94511-1212 S101-6 G95967-0808 S25-4-7DG94511-1616 S101-8

GoodyearGoodyear SafeWay Goodyear SafeWayProduct # Product #

80042-0003 S42-3 80101-0202B BS101-280042-0004 S42-4 80101-0202S SS101-2F80043-0003 S43-3 80101-0206 S101-2-680043-0004 S43-4 80101-0303 S101-380101-0101 S101-1 80101-0303B BS101-380101-0101B BS101-1 80101-0303S SS101-3F80101-0101S SS101-1F 80101-0308 S101-3-880101-0202 S101-2 80101-0404 S101-4

SafeWay Hydraulics, Inc. cross ref., rev.i Page 10

Page 14: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Goodyear (continued)

Goodyear SafeWay Goodyear SafeWayProduct # Product #

80101-0404B BS101-4 80251-0202 S25A-2P80101-0404S SS101-4F 80251-0303 S25-3P80101-0410 S101-4-10 80251-0404 S25-4P80101-0606 S101-6 80251-0408 S25-25P80101-0606B BS101-6 80251-0808 S25-8P80101-0606S SS101-6F 80260-0002 S260-280101-0808 S101-8 80260-0006 S260-680101-0808B BS101-8 80260-0008 S260-880101-0808S SS101-8F 80310-0202 S31-3P80105-0101 S105-1 80310-0303 S31-3P80105-0101B BS105-1 80350-0202 S35-2P80105-0101S SS105-1F 80350-0303 S35-3P80105-0202 S105-2 80360-0202 S360-280105-0202B BS105-2 80360-0303 S360-380105-0202S SS105-2F 80361-0202 S361-280105-0206 S105-2-6 80361-0303 S361-380105-0303 S105-3 80410-0202 S41-280105-0303B BS105-3 80410-0303 S41-380105-0303S SS105-3F 80411-0202 S41-2P80105-0308 S105-3-8 80411-0303 S41-3P80105-0404 S105-4 80450-0202 S45-280105-0404B BS105-4 80450-0303 S45-380105-0404S SS105-5F 80450-0404 S45-480105-0410 S105-4-10 80450-0406 S45-680105-0606 S105-6 80450-0408 S45-1580105-0606B BS105-6 80451-0202 S45-2P80105-0606S SS105-6F 80451-0303 S45-3P80105-0808 S105-8 80451-0404 S45-4P80105-0808B BS105-8 80451-0406 S45-6P80105-0808S SS105-8F 80460-0002 S460-280106-0001 S1060B-1 80460-0003 S460-380106-0002 S1060B-2 80460-0004 S460-480106-0003 S1060B-3 80491-0303 FF491-380106-0004 S1060B-4 80491-0304 FF491-480106-0006 S1060B-6 80491-0308 FF491-3-880106-0008 S1060B-8 80491-0606 FF491-680107-0001 S1061T-1 80491-0612 FF491-6-1280107-0002 S1061T-2 80492-0202 FFE491-280107-0003 S1061T-3 80492-0404 FFE491-480107-0004 S1061T-4 80492-0406 FFE491-4-3/480107-0006 S1061T-6 80492-0412 FFE491-4-1280107-0008 S1061T-8 80492-0606 FFE491-680210-0606 S21F-6 80492-0608 FFE491-6-180211-0808 S21-8P 80492-0808 FFE491-880250-0202 S25A-2 80495-0303 FF495-380250-0303 S25-3 80495-0304 FF495-480250-0404 S25-4 80495-0308 FF495-3-880250-0408 S25-15 80495-0606 FF495-680250-0606 S25F-6 80495-0612 FF495-6-12

SafeWay Hydraulics, Inc. cross ref., rev.i Page 11

Page 15: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Goodyear (continued)

Goodyear SafeWay Goodyear SafeWayProduct # Product #

80496-0202 FFE495-2 80566-0002 S5660B-280496-0404 FFE495-4 80566-0003 S5660B-380496-0406 FFE495-4-3/4 80566-0004 S5660B-480496-0412 FFE495-4-12 80566-0006 S5660B-680496-0606 FFE495-6 80566-0008 S5660B-880496-0608 FFE495-6-1 80567-0002 S5661T-280496-0808 FFE495-8 80567-0003 S5661T-380511-0606 S511-6-STL 80567-0004 S5661T-480511-0606B S511-6 80567-0006 S5661T-680511-0808 S511-8-STL 80567-0008 S5661T-880511-0808B S511-8 80710-0404 S71-480511-1010 S511-10-STL 80710-0406 S71-680511-1010B S511-10 80710-0408 S71-1580512-0008 S512-8 80711-0404 S71-4P80512-0010 S512-10 80711-0406 S71-6P80513-0006 S511-6RK 80711-0408 S71-15P80513-0008 S511-8RK 80750-0404 S75-480513-0010 S511-10RK 80750-0408 S75-1580514-0006 S515-6RK 80760-0004 S760-480514-0008 S515-8RK 80811-0404 S11-480514-0010 S515-10RK 80811-0415 S11-1580515-0606 S515W-6-STL 80812-0404 S12-480515-0606B S515W-6 80812-0416 S12-1680515-0808 S515W-8-STL 80813-0404 S13-480515-0808B S515W-8 80821-0202 S821-2F80515-1010 S515W-10-STL 80821-0302 S821-3-2F80515-1010B S515W-10 80821-0303 S821-3F80561-0202 S561-2 80822-0202 S821-2M80561-0303 S561-3 80822-0302 S821-3-2M80561-0306 S561-3-6 80822-0303 S821-3M80561-0404 S561-4 80825-0202 S825-280561-0408 S561-4-8 80825-0303 S825-380561-0410 S561-4-10 80825-0420 S25-4-2080561-0606 S561-6 80825-0421 S25-4-21P80561-0612 S561-6-12 80825-1520 S25-15-2080561-0808 S561-8 80825-1621 S25-16-21P80561-0816 S561-8-16 80826-0202 S825-2M80565-0202 S565-2 80826-0303 S825-3M80565-0303 S565-3 80924-0403D S25-4-3D80565-0306 S565-3-6 80925-0401 S25-4-180565-0404 S565-4 80925-0402 S25-4-280565-0408 S565-4-8 80925-0403 S25-4-380565-0410 S565-4-10 80925-0404 S25-4-480565-0606 S565-6 80925-0407 S25-4-780565-0612 S565-6-12 80925-0407D S25-4-7D80565-0808 S565-8 80949-5604 FAE49-56-480565-0816 S565-8-16 80956-4904 FAE56-49-4

SafeWay Hydraulics, Inc. cross ref., rev.i Page 12

Page 16: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Hansen

Hansen SafeWay Hansen SafeWay1-H-4 S105-1-4 8-K-16 S101-8-161-H11 S105-1 8-KP16 S101-8-161-K-4 S101-1-4 8-K36 S101-81-K11 S101-1 8-KP36 S101-82-A-16 S561-2 10 S821-2M2-H-6 S105-2-6 10FFP37 FF491-32-H16 S105-2 10FFP50 FF491-42-I-16 S565-2 10FFS37 FF495-32-K-6 S101-2-6 10FFS50 FF495-42-K16 S101-2 11 S821-2F3-A-21 S561-3 12FFP106UN FFE491-4-123-H-8 S105-3-8 12FFP50 FFE491-43-H21 S105-3 12FFP75 FFE491-4-3/43-I-21 S565-3 12FFS106UN FFE495-4-123-K-8 S101-3-8 12FFS50 FFE495-43-K21 S101-3 12FFS75 FFE495-4-3/44-A-26 S561-4 19FFP100 FFE491-6-14-H-10 S105-4-10 19FFp131IN FFE491-6-164-HP10 S105-4-10 19FFP75 FFE491-64-H26 S105-4 19FFS100 FFE495-6-14-HP26 S105-4 19FFS131UN FFE495-6-164-I-26 S565-4 19FFS75 FFE495-64-K-10 S101-4-10 25FFP125 FFE491-8-1144-KP10 S101-4-10 25FFS125 FFE495-8-1144-K26 S101-4 32QS-37F S825-3M4-KP26 S101-4 32QS-37M S825-3M4-ROS-25F S805-2 40 S821-3-2M4-ROS-25M S801-2M 41 S821-3-2F6-A-31 S561-6 42 S821-3M6-FFP-38FA FF491-3 43 S821-3F6-FFP-50FA FF491-4 96-P31 S511-66-FFS-38FA FF495-3 96-P36 S511-86-FFS-50FA FF495-4 96-P36 S511-8-STL6-H-12 S105-6-12 96-P41 S511-106-HP12 S105-6-12 96-P41 S511-10-STL6-H31 S105-6 96-S31 S515W-66-HP31 S105-6 96-S36 S515W-86-I-31 S565-6 96-S36 S515W-8-STL6-K-12 S101-6-12 96-S41 S515W-106-KP12 S101-6-12 96-S41 S515W-10-STL6-K31 S101-6 B1-H11 BS105-16-KP31 S101-6 B1-K11 BS101-18-A-36 S561-8 B2-H16 BS105-28-H-16 S105-8-16 B2-K16 BS101-28-HP16 S105-8-16 B22QS-25M S825-2M8-H36 S105-8 B22QS-25F S825-28-HP36 S105-8 B3-H21 BS105-38-I-36 S565-8 B3-K21 BS101-3

SafeWay Hydraulics, Inc. cross ref., rev.i Page 13

Page 17: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Hansen

Hansen SafeWay Hansen SafeWayB4-H26 BS105-4 LL6-HP31 SS105-6B4-HP26 BS105-4 LL6-K31 SS101-6B4-K26 BS101-4 LL6-KP31 SS101-6B6-H31 BS105-6 LL8-H36 SS105-8B6-HP31 BS105-6 LL8-HP36 SS105-8B6-K31 BS101-6 LL8-K36 SS101-8B8-H36 BS105-8 LL8-KP36 SS101-8B8-HP36 BS105-8 PDC-1-HK S19-1B8-K36 BS101-8 PDC-8-HK S19-8LL1-H11 SS105-1 P-PDC-6FF FF499-3LL1-K11 SS101-1 P-SDC-6FF FF494-3LL2-H16 SS105-2 SDC-1-HK S14-1LL2-K16 SS101-2 SDC-8-HK S14-8LL3-H21 SS105-3 WA 56224 00 S31-3PLL3-K21 SS101-3 WA 56227 00 S35-3PLL4-H26 SS105-4 WA 56514 00 S31-2PLL4-HP26 SS105-4 WA 56517 00 S35-2PLL4-K26 SS101-4 WA 56524 00 S31-3PLL4-KP26 SS101-4 WA 56527 00 S35-3PLL6-H31 SS105-6

HOFMANN

HOFMANN SafeWay HOFMANN SafeWay1DCM S19-1 3DPM S14-31DPM S14-1 3GP S561-31HP S101-1 3GS S565-31HPB BS101-1 3HP S101-31HP-SS SS101-1 3HPB BS101-31HS S105-1 3HP-SS SS101-31HSB BS105-1 3HS S105-31HS-SS SS105-1 3HSB BS105-3210-FA2 S805-2 3HS-SS SS105-3210-FPA2 S801-2F 4DCM S19-4210-MPA2 S801-2M 4DPM S14-42DCM S19-2 4GP S561-42DPM S14-2 4GS S565-42GP S561-2 4HP S101-42GS S565-2 4HPB BS101-42HP S101-2 4HP-SS SS101-42HPB BS101-2 4HS S105-42HP-SS SS101-2 4HSB BS105-42HS S105-2 4HS-SS SS105-42HSB BS105-2 6DCM S19-62HS-SS SS105-2 6DPM S14-63DCM S19-3 6GP S561-6

SafeWay Hydraulics, Inc. cross ref., rev.i Page 14

Page 18: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

HOFMANN (continued)

HOFMANN SafeWay HOFMANN SafeWay6GS S565-6 FF3HS-SS SF495-36HP S101-6 FF46HP FFE491-4-3/46HPB BS101-6 FF46HS FFE495-4-3/46HP-SS SS101-6 FF4HP FFE491-46HS S105-6 FF4HS FFE495-46HSB BS105-6 FF6HP FFE491-66HS-SS SS105-6 FF6HS FFE495-68DCM S19-8 FF8HP FFE491-88DPM S14-8 FF8HS FFE495-88GP S561-8 FPA2 S821-2F8GS S565-8 FPB2 S821-3-2F8HP S101-8 FPB3 S821-3F8HPB BS101-8 G2DCM S59-28HP-SS SS101-8 G2DPM S54-28HS S105-8 G3DCM S59-38HSB BS105-8 G3DPM S54-38HS-SS SS105-8 G4DCM S59-4FA2 S825-2 G4DPM S54-4FB3 S825-3 G6DCM S59-6FF2HP FFE491-2 G6DPM S54-6FF2HS FFE495-2 G8DCM S59-8FF34HP FF491-4 G8DPM S54-8FF34HS FF495-4 MA2 S825-2MFF3DCM FF494-3 MB3 S825-3MFF3DPM FF499-3 MPA2 S821-2MFF3HP FF491-3 MPB2 S821-3-2MFF3HP-SS SF491-3 MPB3 S821-3MFF3HS FF495-3

HOLMBURY

HOLMBURY SafeWay HOLMBURY SafeWayA17F FFE495-6-1 FIMC114-NPT-114-M FFE491-8-114A17M FFE491-6-1 FIMC114-NPT-1-F FFE495-8AD806 FAE56-49-4 FIMC114-NPT-1-M FFE491-8AD807 FAE49-56-4 FIMC114-SAE-114-F FFE495-8-20F HPA 14 NPT S35-2P FIMC114-SAE-114-M FFE491-8-20F HPA 38 NPT S35-3P FIMC14-NPT-1/4-F FFE495-2FIMC100A17 FFE49-6-1 FIMC14-NPT-1/4-M FFE491-2FIMC100-NPT-1-F FFE495-6-1 FIMC34-NPT-1/2-C FFE49-4FIMC100-NPT-1-M FFE491-6-1 FIMC34-NPT-1/2-F FFE495-4FIMC100-NPT-3/4-F FFE495-6 FIMC34-NPT-1/2-M FFE491-4FIMC100-NPT-3/4-M FFE491-6 FIMC34-NPT-3/4-C FF49-6FIMC100-SAE-1-F FFE495-6-16 FIMC34-NPT-3/4-F FF495-6FIMC100-SAE-1-M FFE491-6-16 FIMC34-NPT-3/4-M FF491-6FIMC114-NPT-114-F FFE495-8-114 FIMC34-SAE-3/4-C FF49-6-12

SafeWay Hydraulics, Inc. cross ref., rev.i Page 15

Page 19: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

HOLMBURY (continued)

HOLMBURY SafeWay HOLMBURY SafeWayFIMC34-SAE-3/4-F FF495-6-12 FIRG14-NPT-1/4-F FFE495-2FIMC34-SAE-3/4-M FF491-6-12 FIRG14-NPT-1/4-M FFE491-2FIMC38-NPT-1/2-C FF49-4 FIRG34-NPT-1/2-C FFE49-4FIMC38-NPT-1/2-F FF495-4 FIRG34-NPT-1/2-F FFE495-4FIMC38-NPT-1/2-M FF491-4 FIRG34-NPT-1/2-M FFE491-4FIMC38-NPT-3/8-C FF49-3 FIRG34-NPT-3/4-C FFE49-4-3/4FIMC38-NPT-3/8-F FF495-3 FIRG34-NPT-3/4-F FFE495-4-3/4FIMC38-NPT-3/8-M FF491-3 FIRG34-NPT-3/4-M FFE491-4-3/4FIMC38-NPTM-3/8-F FF495-3M FIRG34-SAE-3/4-C FFE49-4-8FIMC38-SAE-1/2-C FF49-3-8 FIRG34-SAE-3/4-F FFE495-4-8FIMC38-SAE-1/2-F FF495-3-8 FIRG34-SAE-3/4-M FFE491-4-8FIMC38-SAE-1/2-M FF491-3-8 FIRG38-NPT-1/2-C FF49-4FIRG100-NPT-1-F FFE495-6-1 FIRG38-NPT-1/2-F FF495-4FIRG100-NPT-1-M FFE491-6-1 FIRG38-NPT-1/2-M FF491-4FIRG100-NPT-3/4-F FFE495-6 FIRG38-NPT-3/8-C FFE49-3FIRG100-NPT-3/4-M FFE491-6 FIRG38-NPT-3/8-F FFE495-3FIRG100-SAE-1-F FFE495-6-16 FIRG38-NPT-3/8-M FFE491-3FIRG100-SAE-1-M FFE491-6-16 FIRG38-NPTM-3/8-F FF495-3MFIRG114-NPT-114-F FFE495-8-114 FIRG38-SAE-1/2-C FFE49-3-8FIRG114-NPT-114-M FFE491-8-114 FIRG38-SAE-1/2-F FFE495-3-8FIRG114-NPT-1-F FFE495-8 FIRG38-SAE-1/2-M FFE491-3-8FIRG114-NPT-1-M FFE491-8 M HPA 14 NPT S31-2PFIRG114-SAE-114-F FFE495-8-20 M HPA 38 NPT S31-3PFIRG114-SAE-114-M FFE491-8-20 195 652 - Date Code FF495-6-12

Intertraco (Italia)

Intertraco SafeWay Intertraco SafeWayAF15-04 S565-2 BF15-04 S105-2AF15-06 S565-3 BF15-06 S105-3AF15-08 S565-4 BF15-08 S105-4AF15-08 S25-4P BF15-12 S105-6AF15-12 S565-6 BF15-16 S105-8AF15-16 S565-8 BM15-02 S101-1AF18-08 S25-4P-BSP BM15-04 S101-2AF25-08 S25-4 BM15-06 S101-3AM10-08 S561-4-BSP BM15-08 S101-4AM15-04 S561-2 BM15-12 S101-6AM15-08 S561-4 BM15-16 S101-8AM15-08 S71-4P FBIR810 FAE49-56-4AM15-12 S561-6 FBIR811 FAE56-49-4AM15-16 S561-8 FF15-04 FFE495-2AM18-08 S561-4-BSP FF15-06 FFE495-3AM25-08 S71-4P FF15-08 FFE495-4AN15-06 S561-3 FF15-12 FFE495-6BF15-02 S105-1 FF15-16 FFE495-8

SafeWay Hydraulics, Inc. cross ref., rev.i Page 16

Page 20: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Intertraco (Italia) (continued)

Intertraco SafeWay Intertraco SafeWayFF25-12 FFE495-6-1 NF15-16 S25-8PFM15-04 FFE491-2 NF25-04 S25A-2FM15-06 FFE491-3 NF25-06 S25-3FM15-08 FFE495-4 NF25-12 S25F-6FM15-12 FFE491-6 NM15-04 S41-2PFM15-16 FFE491-8 NM15-06 S41-3PFM25-12 FFE491-6-1 NM15-16 S21-8PJF25-04 S35-2P NM25-04 S41-2JF25-06 S35-3P NM25-06 S41-3JM25-04 S31-2P NM25-12 S21F-6JM25-06 S31-3P PF10-08 S45-4P-BSPNF15-04 S25A-2P PF15-08 S45-4PNF15-06 S25-3P PF25-08 S45-4

Parker / Pioneer

Parker/Pioneer SafeWay Parker/Pioneer SafeWay3000-2 S30-2P 4050-5 S45-63000-3 S30-3P 4050-6P S25-8P3005-2 S34-2 4050-15 S25-153005-3 S34-3 4050-16 S25-163009-2 S39-2 4050-29BSPP S25-4P-BSP3009-3 S39-3 4056-4 S25-4-203010-2 S31-2P 4056-15 S25-15-203010-3 S31-3P 4057-4 S25-4-21P3050-2 S35-2P 4057-16 S25-16-21P3050-3 S35-3P 4060-4 S25-4-14000-2 S20A2 4065-4 S25-4-34000-2P S20A-2P 4065-4LS S25-4-3D4000-3 S40-3 4067-4 S25-4-44000-4 S20-4 4068-4 S25-4-94000-5 S40-6 4070-4 S25-4-24000-6P S20-8P 4075-4 S25-4-74000-15 S20-15 4075-4LS S25-4-7D4000-16 S20-16 4076-4 S25-4-54000-29BSPP S20-4P-BSP 4080-4 S25-4-64010-2 S41-2 4085-4 S25-4-84010-2P S41-2P 4086-4 S25-4-104010-3 S41-3 4100-5 S20F-64010-3P S41-3P 4110-5 S21F-64010-6P S21-8P 4150-5 S25F-64050-2 S25A-2 4200-3P S40-3P4050-2P S25A-2P 4200-4 S40-44050-3 S25-3 4200-15 S40-154050-3P S25-3P 4250-3P S45-3P4050-4 S25-4 4250-4 S45-4

SafeWay Hydraulics, Inc. cross ref., rev.i Page 17

Page 21: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Parker / Pioneer (continued)

Parker/Pioneer SafeWay Parker/Pioneer SafeWay4250-15 S45-15 6135-12 S515H-65006-4 S42-4 6135-16 S515H-85060-4 S11-4 6135-16 S515H-8-STL5060-15 S11-15 6135-20 S515H-105070-4 S12-4 6135-20 S515H-10-STL5070-16 S12-16 6601-4-4 S565-25077-4 S71-4P 6601-6-6 S565-35077-16 S71-16P 6601-8-10 S565-45080-4 S13-4 6601-12-12 S565-65090-4 S71-4P 6601-16-16 S565-85205-2 S44-2 6602-4-4 S561-25205-3 S44-3 6602-6-6 S561-35205-4 S44-4 6602-8-10 S561-45205-5 S44-6 6602-12-12 S561-65205-6 S44-8 6602-16-16 S561-85209-2 S49-2 6608-6-6 S565-3-65209-3 S49-3 6608-8-10 S565-4-85209-4 S49-4 6608-10-10 S565-4-105209-5 S49-6 6608-12-12 S565-6-125209-6 S49-8 6608-16-16 S565-8-166105-12 S511-6 6610-6-6 S561-3-66105-16 S511-8 6610-8-10 S561-4-86105-16 S511-8-STL 6610-10-10 S561-4-106105-20 S511-10 6610-12-12 S561-6-126105-20 S511-10-STL 6610-16-16 S561-8-166107-12 S512-6 6657-4 S59-26107-16 S512-8 6657-6 S59-36107-20 S512-10 6657-10 S59-46108-12 S519-6 6657-12 S59-66108-16 S519-8 6657-16 S59-86108-20 S519-10 6659-4 S54-26109-12 S514-6 6659-6 S54-36109-16 S514-8 6659-10 S54-46109-20 S514-10 6659-12 S54-66120-12 S51W-6 6659-16 S54-86120-16 S51W-8 8010-4 S71-46120-16 S51W-8-STL 8010-4P S71-4P6120-20 S51W-10 8010-5 S71-66120-20 S51W-10-STL 8010-15 S71-156125-16 S515W-8 8010-16 S71-166125-16 S515W-8-STL 8010-29BSPP S561-4-BSP6125-20 S515W-10 8200-4 S70-46125-20 S515W-10-STL 8200-16 S70-166130-12 S51H-6 8250-4 S75-46130-16 S51H-8 8250-16 S75-166130-16 S51H-8-STL 8500-4 S77-46130-20 S51H-10 BH1-60 BS105-16130-20 S51H-10-STL BH1-61 BS101-1

SafeWay Hydraulics, Inc. cross ref., rev.i Page 18

Page 22: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Parker / Pioneer (continued)

Parker/Pioneer SafeWay Parker/Pioneer SafeWayBH2-60 BS105-2 H1-63 S101-1BH2-61 BS101-2 H1-63-T4 S101-1-4BH3-60 BS105-3 H1E S821-3-2FBH3-61 BS101-3 H2-62 S105-2BH4-60 BS105-4 H2-62-T6 S105-2-6BH4-61 BS101-4 H2-63 S101-2BH6-60 BS105-6 H2-63-T6 S101-2-6BH6-61 BS101-6 H2-65 S14-2BH8-60 BS105-8 H2-66 S19-2BH8-61 BS101-8 H2C S821-2MEAS-500 FAE49-56-4 H2E S821-3MFA2-B S825-2 H3-62 S105-3FB3 S825-3 H3-62-T8 S105-3-8FE-501-8FP FFE495-4 H3-63 S101-3FE-501-12FO FF495-6-12 H3-63-T8 S101-3-8FE-502-8FP FFE491-4 H3-65 S14-3FE-502-12FO FF491-6-12 H3-66 S19-3FEM-1001-16FP-NL FFE495-8 H3C S821-2FFEM-1002-16FP FFE491-8 H3E S821-3FFEM-251-4P-NL FFE495-2 H4-62 S105-4FEM-251-6FO-NL FFE495-2-6 H4-62-T10 S105-4-10FEM-252-4FP FFE491-2 H4-63 S101-4FEM-252-6FO FFE491-2-6 H4-63-T10 S101-4-10FEM-371-6FP-NL FFE495-3 H4-65 S14-4FEM-371-8FO-NL FFE495-3-8 H4-66 S19-4FEM-372-6FP FFE491-3 H6-62 S105-6FEM-372-8FO FFE491-3-8 H6-62-T12 S105-6-12FEM-501-8FO-NL FFE495-4-8 H6-63 S101-6FEM-501-10FO FFE495-4-10 H6-63-T12 S101-6-12FEM-501-12FO FFE495-4-12 H6-65 S14-6FEM-501-8FP-NL FFE495-4 H6-66 S19-6FEM-502-8FO FFE491-4-8 H8-62 S105-8FEM-502-10FO FFE491-4-10 H8-62-T16 S105-8-16FEM-502-12FO FFE491-4-12 H8-63 S101-8FEM-502-8FP FFE491-4 H8-63-T16 S101-8-16FEM-751-12FP-NL FFE495-6 H8-65 S14-8FEM-752-12FP FFE491-6 H8-66 S19-8FF-371-6FP FF495-3 MA2-B S825-2MFF-371-8FO FF495-3-8 MB3 S825-3MFF-371-8FP FF495-4 NR-37 FF499-3FF-372-6FP FF491-3 NR-50 FF494-3FF-372-8FO FF491-3-8 SAE-500 FAE56-49-4FF-372-8FP FF491-4 SH1-62 SS105-1FS-371-6FP SF495-3 SH1-63 SS101-1FS-372-6FP SF491-3 SH2-62 SS105-2H0E S821-3-2M SH2-63 SS101-2H1-62 S105-1 SH3-62 SS105-3H1-62-T4 S105-1-4 SH3-63 SS101-3

SafeWay Hydraulics, Inc. cross ref., rev.i Page 19

Page 23: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Parker / Pioneer (continued)

Parker/Pioneer SafeWay Parker/Pioneer SafeWaySH4-62 SS105-4 VP4075-4L CPS25-4-7DSH4-63 SS101-4 VP4076-4 CPS25-4-5SH6-62 SS105-6 VP4080-4 CPS25-4-6SH6-63 SS101-6 VP4085-4 CPS25-4-8SH8-62 SS105-8 VP4200-4 CPS40-4SH8-63 SS101-8 VP4200-4P CPS40-4PSM-251-4FP SH25-2P VP5060-15 CPS11-15SM-251-6FO SH25-14P VP5060-4 CPS11-4SM-251-6FP SH25-2-3P VP5070-16 CPS12-16SM-252-4FP SH21-2P VP5070-4 CPS12-4SM-252-6FO SH21-14P VP5080-4 CPS13-4VP4000-2P CPS20A-2P VP5205-2M CPS44-2VP4000-3P CPS20-3P VP5205-3M CPS44-3VP4000-4 CPS20-4 VP5205-4M CPS44-4VP4000-4P CPS20-4P VP5209-2M CPS49-2VP4010-2P CPS41-2P VP5209-3M CPS49-3VP4010-3P CPS41-3P VP5209-4M CPS49-4VP4056-15 CPS25-15-20 VP8010-15 CPS71-15VP4056-4 CPS25-4-20 VP8010-15P CPS71-15PVP4057-4 CPS25-4-21P VP8010-16 CPS71-16VP4060-4 CPS25-4-1 VP8010-16P CPS71-16PVP4065-4 CPS25-4-3 VP8010-4 CPS71-4VP4065-4L CPS25-4-3D VP8010-4P CPS71-4PVP4067-4 CPS25-4-4 VP8010-5 CPS71-6VP4070-4 CPS25-4-2 VP8200-4 CPS70-4VP4075-4 CPS25-4-7

Snap-Tite

Snap-Tite SafeWay Snap-Tite SafeWay21C4-4F S45-2 60N6-6RP S41-3P-BSP60C4-4F S25A-2P 61C12-12F S565-660C4-4FV S25A-2P-F 61C12-12FV S565-6F60C6-6F S45-3P 61C16-16F S565-860C6-6FV S45-3P-F 61C16-16FV S565-8F60C6-6RP S45-3P-BSP 61C4-4F S565-260N4-4F S41-2P 61C4-4FV S565-2F60N4-4FV S41-2P-F 61C6-6F S565-360N6-6F S41-3P 61C6-6FV S565-3F60N6-6FV S41-3P-F 61C8-8EF S25-15

SafeWay Hydraulics, Inc. cross ref., rev.i Page 20

Page 24: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Snap-Tite (continued)

Snap-Tite SafeWay Snap-Tite SafeWay61C8-8F S25-4 72N8-8F S101-461C8-8F S565-4 72N12-12F S101-661C8-8FV S565-4F 72N16-16F S101-861DC8-8EF S45-15P 72PDC-4 S19-261DC8-8F S45-4P 72PDC-6 S19-361DC8-8RP S45-4P-BSP 72PDC-8 S19-461N12-12F S561-6 72PDC-12 S19-661N12-12FV S561-6F 72PDC-16 S19-861N16-16F S561-8 72PDP-4 S14-261N16-16FV S561-8F 72PDP-6 S14-361N4-4F S561-2 72PDP-8 S14-461N4-4FV S561-2F 72PDP-12 S14-661N6-6F S561-3 72PDP-16 S14-861N6-6FV S561-3F 74C4-4F FFE495-261N8-8F S561-4 74C6-6F FF495-361N8-8FV S561-4F 74C6-8EF FF495-3-861PDC-4 S59-2 74C6-8F FF495-461PDC-6 S59-3 74C8-8F FFE495-461PDC-8 S59-4 74C8-10EF FFE495-4-1061PDC-12 S59-6 74C8-12EF FFE495-4-1261PDC-16 S59-8 74C8-12F FFE495-4-3/461PDP-4 S54-2 74C8-12F FF495-661PDP-6 S54-3 74C12-1EF FFE491-6-1661PDP-8 S54-4 74C12-12F FFE495-661PDP-12 S54-6 74C12-16EF FFE495-6-1662C8-62NB S25-4-1 74C12-16F FFE495-6-162C8-63N8 S25-4-3 74C16-16EF FFE495-8-2062C8-67N8 S25-4-2 74C16-16F FFE495-862C8-67N8 S25-4-4 74N4-4F FFE491-262N8-8EF S11-15 74N6-6F FF491-362N8-8F S11-4 74N6-8EF FF491-3-863N8-8EF S71-15P 74N6-8F FF491-463N8-8F S71-4P 74N8-8F FFE491-463N8-8RP S561-4-BSP 74N8-10EF FFE491-4-1067C8-62N8 S25-4-5 74N8-12EF FFE491-4-1267C8-63N8 S25-4-7 74N8-12F FFE491-4-3/467N8-8EF S12-16 74N8-12F FF491-667N8-8F S12-4 74N12-12F FFE491-668C8-8EF S75-15 74N12-16F FFE491-6-168C8-8F S75-4 74N16-1EF FFE491-8-2068C8-8RP S75-4-BSP 74N16-16F FFE491-872C4-4F S105-2 76C6-6M S35-3P72C6-6F S105-3 76N6-6F S31-3P72C8-8F S105-4 78C12-12F S515W-672C12-12F S105-6 78C16-16F S515W-872C16-16F S105-8 78C16-16F S515W-8-STL72N4-4F S101-2 78C20-20F S515W-1072N6-6F S101-3 78C20-20F S515W-10-STL

SafeWay Hydraulics, Inc. cross ref., rev.i Page 21

Page 25: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Snap-Tite (continued)

Snap-Tite SafeWay Snap-Tite SafeWay78CN12-12F S51W-6 78N16-16F S511-8-STL78CN16-16F S51W-8 78N20-20F S511-1078CN16-16F S51W-8-STL 78N20-20F S511-10-STL78CN20-20F S51W-10 78PD-16 S54-878CN20-20F S51W-10-STL B72C12-12F BS105-678DC-12 S59-6 B72C4-4F BS105-278DC-16 S59-8 B72C8-8F BS105-478DC-20 S59-10 B72N12-12F BS101-678DP-12 S54-6 B72N16-16F BS101-878DP-20 S54-10 B72N4-4F BS101-278F-12 S512-6 B72N6-6F BS101-378F-16 S512-8 B72N8-8F BS101-478F-20 S512-10 S72C12-12F SS105-678HC12-12F S515H-6 S72C16-16F SS105-878HC16-16F S515H-8 S72C6-6F SS105-378HC16-16F S515H-8-STL S72C8-8F SS105-478HC20-20F S515H-10 S72N12-12F SS101-678HC20-20F S515H-10-STL S72N16-16F SS101-878HCN16-16F S51H-8-STL S72N4-4F SS101-278HCN20-20F S51H-10-STL S72N4-4F SS105-278N12-12F S511-6 S72N6-6F SS101-378N16-16F S511-8 S72N8-8F SS101-4

Stucchi

Stucchi SafeWay Stucchi SafeWayF. A7 1/4 NPT FFE495-2 F. FIRG 12 NPT FF495-4 (10,000 PSI)F. A9 1/2 NPT FF495-4 (10,000 PSI) F. FIRG 12A NPT FFE495-4F. A9 1/2 SAE FF495-3-8 (10,000 PSI) F. FIRG 14 NPT FFE495-2F. A9 3/8 NPT FF493-3 (10,000 PSI) F. FIRG 34 NPT FFE495-4-3/4F. A13 1/2 NPT FFE495-4 F. FIRG 34A NPT FFE495-6F. A13 3/4 NPT FFE495-4-3/4 F. FIRG 38 NPT FF495-3 (10,000 PSI)F. A13 3/4 SAE FFE495-4-12 F. FIRG 100 NPT FFE495-8F. A13 5/8 SAE FFE495-4-10 F. FIRG 34 SAE FFE495-4-12F. A17 1" NPT FFE495-6-1 F. FIRG 38 1/2 SAE FF495-3-8F. A17 1" SAE FFE495-6-16 F. FIRG 100 SAE FFE495-6-16F. A17 3/4 NPT FFE495-6 F. IR 12 NPT S25-4F. A21 1" NPT FFE495-8 F. IR 14 NPT S25A-2F. A21 1" SAE FFE495-8-20 F. IR 34 NPT S25F-6F. A21 114 NPT FFE495-8-114 F. IR 38 NPT S25-3F. BIR 12 NPT S565-4 F. IR 100 NPT S25-8PF. BIR 12 NPT S25-3P F. IRB 12 NPT S105-4F. BIR 14 NPT S565-2 F. IRB 14 NPT S105-2F. BIR 34 NPT S565-6 F. IRB 18 NPT S105-1F. BIR 38 NPT S565-3 F. IRB 34 NPT S105-6F. BIR 100 NPT S565-8 F. IRB 38 NPT S105-3

SafeWay Hydraulics, Inc. cross ref., rev.i Page 22

Page 26: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Stucchi (continued)

Stucchi SafeWay Stucchi SafeWayF. IRB 100 NPT S105-8 M. BIR 100 NPT S561-8F.IRBOV 12 NPT BS105-4 M. FIRG 12 NPT FF491-4 (10,000 PSI)F.IRBOV 14 NPT BS105-2 M. FIRG 12A NPT FFE491-4F.IRBOV 18 NPT BS105-1 M. FIRG 14 NPT FFE491-2F.IRBOV 34 NPT BS105-6 M. FIRG 34 NPT FFE491-4-3/4F.IRBOV 38 NPT BS015-3 M. FIRG 34A NPT FFE491-6F.IRBOV 100 NPT BS105-8 M. FIRG 38 NPT FF491-3 (10,000 PSI)F. IRBX 12 NPT SS105-4 (303 SS) M. FIRG 100 NPT FFE491-8F. IRBX 14 NPT SS105-2 (303 SS) M. FIRG 34 SEA FFE491-4-12F. IRBX 18 NPT SS105-1 (303 SS) M. FIRG 38 1/2 SAE FF491-3-8F. IRBX 34 NPT SS105-6 (303 SS) M. FIRG 100 SAE FFE491-6-16F. IRBX 38 NPT SS105-3 (303 SS) M. IR 12 NPT S71-4F. IRBX 100 NPT SS105-8 (303 SS) M. IR 14 NPT S41-2F. IRS 12A NPT S45-4 M. IR 34 NPT S21F-6F. IRS 12VA NPT S45-4P M. IR 38 NPT S41-3F. IRS 12VA PC NPT S75-4 M. IR 100 NPT S21-8PF. IRV 14 NPT S25A-2P M. IRB 12 NPT S101-4F. IRV 34 NPT S25F-6 M. IRB 14 NPT S101-2F. IRV 38 NPT S25-3P M. IRB 18 NPT S101-1F. IRV 100 NPT S25-8P M. IRB 34 NPT S101-6F. IVHP 14 NPT S35-2P M. IRB 38 NPT S101-3F. IVHP 38 NPT S35-3P M. IRB 100 NPT S101-8F. W6F6-B S515W-6 M.IRBOV 12 NPT BS101-4F. W6F6-B S515W-6-STL M.IRBOV 14 NPT BS101-2F. W8F8-B S515W-8 M.IRBOV 18 NPT BS101-1F. W8F8-B S515W-8-STL M.IRBOV 34 NPT BS101-6F. W10F10-B S515W-10 M.IRBOV 38 NPT BS101-3F. W10F10-B S515W-10-STL M.IRBOV 100 NPT BS101-8M. A7 1/4 NPT FFE491-2 M. IRBX 12 NPT SS101-4 (303 SS)M. A9 1/2 NPT FF491-4 (10,000 PSI) M. IRBX 14 NPT SS101-2 (303 SS)M. A9 1/2 SAE FF491-3-8 (10,000 PSI) M. IRBX 18 NPT SS101-1 (303 SS)M. A9 3/8 NPT FF491-3 (10,000 PSI) M. IRBX 34 NPT SS101-6 (303 SS)M. A13 1/2 NPT FFE491-4 M. IRBX 38 NPT SS101-3 (303 SS)M. A13 3/4 NPT FFE491-4-3/4 M. IRBX 100 NPT SS101-8 (303 SS)M. A13 3/4 SAE FFE491-4-12 M. IRV 14 NPT S41-2PM. A13 5/8 SAE FFE491-4-10 M. IRV 34 NPT S21F-6M. A17 1" NPT FFE491-6-1 M. IRV 38 NPT S41-3PM. A17 1" SAE FFE491-6-16 M. IVHP 14 NPT S31-2PM. A17 3/4 NPT FFE491-6 M. IVHP 38 NPT S31-3PM. A21 1" NPT FFE491-8 M. IRV 100 NPT S21-8PM. A21 1" SAE FFE491-8-20 M. W10F10-B S511-10M. A21 114 NPT FFE491-8-114 M. W10F10-B S511-10-STLM. BIR 12 NPT S561-4 M. W6F6-B S511-6M. BIR 12 NPT S71-4P M. W6F6-B S511-6-STLM. BIR 14 NPT S561-2 M. W8F8-B S511-8M. BIR 34 NPT S561-6 M. W8F8-B S511-8-STLM. BIR 38 NPT S561-3

SafeWay Hydraulics, Inc. cross ref., rev.i Page 23

Page 27: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

TEMA SafeWay TEMA SafeWayA10010N S565-8 K2-242D S805-2A10020N S561-8 N3-222D-2 S801-2FA5510B S25-4P-BSP N3-223D-S S801-2MA5510N S565-4 TIF2510 FFE495-2A5520B S561-4-BSP TIF2520 FFE491-2A5520N S561-4 TIF3810 FF495-3B10010N S105-8 TIF3810-50 FF495-4B10020N S101-8 TIF3820 FF491-3 B2510N S105-2 TIF3820-50 FF491-4B2520N S101-2 TIF5010 FFE495-4B3810N S105-3 TIF5010-75 FFE495-4-3/4B3820N S101-3 TIF5020 FFE495-4B5010N S105-4 TIF5020-75 FFE491-4-3/4B5020N S101-4 TIF7510 FFE495-6B7510N S105-6 TIF7510-100 FFE495-6-1B7520N S101-6 TIF7520 FFE491-6K2-232D S825-2 TIF7520-100 FFE491-6-1K2-233D S825-2M

TOMCO SafeWay TOMCO SafeWay200 S801-2M 51H-16 S515H-8300 S801-2F 51H-16 S515H-8-STL2H-DP S14-2 51H-20 S515H-102K-DP S54-2 51H-20 S515H-10-STL2R-DP S44-2 51P-12 S511-62RF2-PV S25A-2P 51P-16 S511-83H-DP S14-3 51P-20 S511-103HTF3 FF495-3 51P-20 S511-10-STL3HTF4 FF495-4 51W-12 S515W-63K-DP S54-3 51W-16 S515W-8-STL4H-DP S14-4 51W-16 S515W-84K-DP S54-4 51W-20 S515W-104R-DP S44-4 51W-20 S515W-10-STL4RF4 S25-4 5602DC S59-251DC-12 S59-6 5602DP S54-251DC-16 S59-8 5603DC S59-351DC-20 S59-10 5603DP S54-351DP-12 S54-6 5604DC S59-451DP-16 S54-8 5604DP S54-451DP-20 S54-10 5606DC S59-651F-12 S512-6 5606DC FF494-351F-16 S512-8 5606DP S54-651F-20 S512-10 5608DC S59-851H-12 S515H-6 5608DP S54-8

TEMA (Rectus)

TOMCO

SafeWay Hydraulics, Inc. cross ref., rev.i Page 24

Page 28: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

TOMCO SafeWay TOMCO SafeWay6H-DP S14-6 K4-DC S59-46K-DP S54-6 K6-DC S59-66WF6-B S515W-6 K8-DC S59-88H-DP S14-8 M100 S805-28K-DP S54-8 PA5602-16 S561-28WF8-B S515W-8 PA5603-21 S561-310WF10-B S515W-10 PA5604-26 S561-4CA5602-16 S565-2 PA5606-31 S561-6CA5603-21 S565-3 PA5608-36 S561-8CA5604-26 S565-4 R2-DC S49-2CA5606-31 S565-6 R2F2-PV S41-2PCA5608-36 S565-8 R4-DC S49-4EC2-16 FFE495-2 R4F4 S71-4EC3-8 FF495-3-8 TH1-11 S105-1EC3-21 FF495-3 TH1-11-002 BS105-1EC3-26 FF495-4 TH1-11-303 SS105-1EC4-12 FFE495-4-12 TH1D S14-1EC4-12 FF495-6-12 TH2-16 S105-2EC4-26 FFE495-4 TH2-16-002 BS105-2EC4-31 FF495-6 TH2-16-303 SS105-2EC6-31 FFE495-6-1 TH2D S14-2EC8-36 FFE495-8 TH3-21 S105-3EP2-16 FFE491-2 TH3-21-002 BS105-3EP3-8 FF491-3-8 TH3-21-303 SS105-3EP3-21 FF491-3 TH3D S14-3EP3-26 FF491-4 TH4-26 S105-4EP4-12 FFE491-4-12 TH4-26-002 BS105-4EP4-12 FF491-6-12 TH4-26-303 SS105-4EP4-26 FFE491-4 TH4D S14-4EP4-31 FF491-6 TH6-31 S105-6EP6-31 FFE491-6-1 TH6-31-002 BS105-6EP8-36 FFE491-8 TH6-31-303 SS105-6FC3-21 FF495-3 TH6D S14-6FC3-21-316 SF495-3 TH8-36 S105-8FC3-26 FF495-4 TH8-36-002 BS105-8FP3-21 FF491-3 TH8-36-303 SS105-8FP3-21-316 SF491-3 TH8D S14-8FP3-26 FF491-4 TK1-11 S101-1FP3DC FF499-3 TK1-11-002 BS101-1H2-DC S19-2 TK1-11-303 SS101-1H3-DC S19-3 TK1D S19-1H4-DC S19-4 TK2-16 S101-2H6-DC S19-6 TK2-16-002 BS101-2H8-DC S19-8 TK2-16-303 SS101-2HT3F3 FF491-3 TK2D S19-2HT3F4 FF491-4 TK3-21 S101-3K2-DC S59-2 TK3-21-002 BS101-3K3-DC S59-3 TK3-21-303 SS101-3

TOMCO (continued)

SafeWay Hydraulics, Inc. cross ref., rev.i Page 25

Page 29: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

TOMCO SafeWay TOMCO SafeWayTK3D S19-3 TK8-36-002 BS101-8TK4-26 S101-4 TK8-36-303 SS101-8TK4-26-002 BS101-4 TK8D S19-8TK4-26-303 SS101-4 W10-BMF S512-10TK4D S19-4 W10F10-B S511-10TK6-31 S101-6 W6-BMF S512-6TK6-31-002 BS101-6 W6F6-B S511-6TK6-31-303 SS101-6 W8-BMF S512-8TK6D S19-6 W8F8-B S511-8TK8-36 S101-8

Original Equipment Manufacturers (O.E.M.)

Allis-Chalmers

Allis-Chalmers SafeWay Allis-Chalmers SafeWay246571 S25-4 271535 S25-4-1271532 S25-4-7 594977 S71-4271533 S25-4-2271534 S25-4-3

Enerpac

Enerpac SafeWay Enerpac SafeWay

C-604 S30-3P CR-400 S35-3PCH-604 S31-3P

Ford®

Ford SafeWay Ford SafeWayD-5NN-B961-A S71-15PD-3NN-B964-A S71-4P

TOMCO (continued)

SafeWay Hydraulics, Inc. cross ref., rev.i Page 26

Page 30: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

CASE IH

CASE / IH SafeWay CASE / IH SafeWay1272770 S12-4 544788R1 S25-16-21P1272399C1 S71-16 58824C1 S25-4-21272400C1 S25-15P A147441 S75-41272770C1 S71-4 A147889 S71-161285718C2 S71-15 A160879 S25-4-3187562C1 SH21-14 A160880 S25-4-7187563C1 SH25-14 A160884 S13-4395149R91 S71-16P A160937 S71-4395151R1 S71-4P AF-3000-R S20-4544787R1 S25-4-21P C-23939 S25-4544787R91 S12-16

John Deere®

John Deere SafeWay John Deere SafeWayAE36785 S75-4 X4000-16 S20-16AH75167 S25-15 X4000-16P S40-4PAM37982 S25A-2P X4010-2 S41-2AM37983 S41-2P X4010-2P S41-2PAR30210 (old) S11-15 X4050-2 S25A-2AR47331 (old) S25-15-20 X4050-2P S25A-2PAR93819 (new) S11-15 X4100-5 S21F-6AR94522 S71-15P X4200-3P S40-3PAR98201 S25-4-1 X4200-4 S40-4AR98202 S25-4-3D X4200-4P S40-4PC14618 S71-4 X4200-15 S40-15C14619 S25-4 X4200-15P S40-15PRE-11447 S11-4 X6601-4-4 S565-2RE11456 S25-4-5 X6602-4-4 S561-2RE11457 S25-4-7 X6602-6-6 S561-3RE11458 S25-4-4 XBH1-60 BS105-1RE15361 (new) S25-15-20 XBH1-61 BS101-1X3010-2 S31-2P XBH2-60 BS105-2X3010-3 S31-3P XBH2-61 BS101-2X3050-2 S35-2P XFF-372-6FP FF491-3X3050-3 S35-3P XFF-372-8FP FF491-4X4000-2 S20A-2 XH1-62 S105-1X4000-2P S20A-2P XH1-63 S101-1X4000-3 S20-3 XH2-62 S105-2X4000-4 S20-4 XH2-63 S101-2X4000-4P S20-4P XSH1-62 SS105-1X4000-5 S20F-6 XSH1-63 SS101-1X4000-5P S20F-6 XSH2-62 SS105-2X4000-6P S20-8P XSH2-63 SS101-2X4000-15 S20-15 XSM-252-4FP SH21-2PX4000-15P S20-15P

SafeWay Hydraulics, Inc. cross ref., rev.i Page 27

Page 31: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Massey Ferguson (AGCO)

Massey SafeWay Massey SafeWay1026700M91 S71-15 1903885M91 S25-4-31086692M91 S25-4 1903886M91 S25-4-21900971M91 S75-4 1903887M91 S25-4-71903882M91 S41-2 242678M91 S71-41903883M91 S25A-21903884M91 S25-4-1

Melroe (Bobcat)

Melroe SafeWay Melroe SafeWay6667808 FFE495-4-12 6667808 FFE491-4-126667808 FF495-6-12 6667808 FF491-6-12

New Holland

Versatile SafeWay Versatile SafeWay69197 S75-15 106217 S760-475906 S44-4 82980523 S75-1576462 S71-15 82980524 S71-1576463 S49-4 82980532 S44-488711 S20-15P 82980545 S49-488713 S20-16P

Power Team® (SPX Fluid Power)

Power Team SafeWay Power Team SafeWay9790 FF494-3 9797 S34-39791 FF499-3 9798 S31-3P9792 FF495-3M 9799 S39-39793 FF491-39794 FF49-3M9796 S35-3P

SafeWay Hydraulics, Inc. cross ref., rev.i Page 28

Page 32: Hydraulic Quick Coupling Interchange - SCISMRO · Hydraulic Quick Coupling Interchange Updated April 2009 ... sional integrity within an accepted interchange; ... 1. QUICK COUPLINGS

Skid Steer Loaders & AttachmentsASV

For Model No. Use SafeWay OR For Model No. Use SafeWay(ISO 16028) (Heavy Duty)

RC50, RC60, RC85 FFE495-4-10 (Body) RC100 FF495-6-12 (Body)RC50, RC60, RC85 FFE491-4-10 (Tip) RC100 FF491-6-12 (Tip)RC100 FFE491-4-12 (Tip)RC100 FFE495-4-12 (Body)

Bobcat (2001 or Older)For Model No. Use SafeWay OR For Model No. Use SafeWay

(ISO 16028) (Heavy Duty)463, 553, 753, 763 FFE495-4-10 (Body) 773, 863, 873, 963 FF495-6-12 (Body)463, 553, 753, 763 FFE491-4-10 (Tip) 773, 863, 873, 963 FF491-6-12 (Tip)773, 863, 873, 963 FFE495-4-12 (Body)773, 863, 873, 963 FFE491-4-12 (Tip)

Gehl/ Mustang (2004 or Older)For Model No. Use SafeWay OR For Model No. Use SafeWay

(ISO 16028) (ISO 16028)4640 & 4840 FFE495-4-12 (Body) 4640 & 4840 FF495-6-12 (Body)4640 & 4840 FFE491-4-12 (Tip) 4640 & 4840 FF491-6-12 (Tip)5640 & 6640 FFE495-4-12 (Body) 5640 & 6640 FF495-6-12 (Body)5640 & 6640 FFE491-4-12 (Tip) 5640 & 6640 FF491-6-12 (Tip)

John DeereFor Model No. Use SafeWay OR For Model No. Use SafeWay

(ISO 16028) (Heavy Duty)325, 328, 332 FFE495-4-12 (Body) 325, 328, 332 FF495-6-12 (Body)325, 328, 332 FFE491-4-12 (Tip) 325, 328, 332 FF491-6-12 (Tip)

Thomas EquipmentFor Model No. Use SafeWay For Model No. Use SafeWay

(Newer) (ISO 16028) (Older) (ISO 16028)85, 105, 137, 153, 175 FFE495-4-10 (Body) 85, 105, 137, 153, 175 FFE495-4 (Body)85, 105, 137, 153, 175 FFE491-4-10 (Tip) 85, 105, 137, 153, 175 FFE491-4 (Tip)205, 250, 255, 320 FFE495-4-10 (Body) 205, 250, 255, 320 FFE495-4 (Body)205, 250, 255, 320 FFE491-4-10 (Tip) 205, 250, 255, 320 FFE491-4 (Tip)

VolvoFor Model No. Use SafeWay OR For Model No. Use SafeWay

(ISO 16028) (Heavy Duty)MC60, MC70, MC80 FFE495-4-10 (Body) MC90 & MC10 FF495-6-12 (Body)MC60, MC70, MC80 FFE491-4-10 (Tip) MC90 & MC10 FF491-6-12 (Tip)

SafeWay Hydraulics, Inc. cross ref., rev.i Page 29