Hydraulic Motors M5AS/M5ASF - Comoso€¦ · M5a - M5aS M5aSF! FaIlUre Or IMPrOPer SeleCTIOn Or...

16
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Hydraulic Motors M5AS/M5ASF Denison Vane Technology, Fixed Displacement

Transcript of Hydraulic Motors M5AS/M5ASF - Comoso€¦ · M5a - M5aS M5aSF! FaIlUre Or IMPrOPer SeleCTIOn Or...

  • Hydraulic MotorsM5AS/M5ASFDenison Vane Technology, fixed displacement

    aerospaceclimate controlelectromechanicalfiltrationfluid & gas handlinghydraulicspneumaticsprocess controlsealing & shielding

    Hydraulic MotorsM5AS/M5ASFDenison Vane Technology, Fixed Displacement

  • 2

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors

    3

    ContentsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    2 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Warning .............................................................................. 2

    General characteristics ....................................................... 3

    Description ......................................................................... 4

    Ports and hydraulic fluids..................................................... 5

    Motor selection ................................................................... 6

    Fluid power formulas .......................................................... 6

    Performance data ............................................................... 7

    Max. ratings ........................................................................ 8

    Technical data .............................................................. 9 - 10

    Ordering code ................................................................... 11

    Motor with side ports - Dimensions .................................. 12

    Motor with opposite ports - Dimensions ........................... 13

    Ordering code ................................................................... 11

    Motor with side ports - Dimensions .................................. 14

    Motor with opposite ports - Dimensions ........................... 15

    general

    M5a - M5aS

    M5aSF

    Content

    !FaIlUre Or IMPrOPer SeleCTIOn Or IMPrOPer USe OF THe PrODUCTS DeSCrIBeD HereIn Or relaTeD ITeMS Can CaUSe DeaTH, PerSOnal InJUrY anD PrOPerTY DaMage.

    This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.

    The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.

    To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

    Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.

    WARNING – USER RESPONSIBILITY

    Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    2 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Warning .............................................................................. 2

    General characteristics ....................................................... 3

    Description ......................................................................... 4

    Ports and hydraulic fluids..................................................... 5

    Motor selection ................................................................... 6

    Fluid power formulas .......................................................... 6

    Performance data ............................................................... 7

    Max. ratings ........................................................................ 8

    Technical data .............................................................. 9 - 10

    Ordering code ................................................................... 11

    Motor with side ports - Dimensions .................................. 12

    Motor with opposite ports - Dimensions ........................... 13

    Ordering code ................................................................... 11

    Motor with side ports - Dimensions .................................. 14

    Motor with opposite ports - Dimensions ........................... 15

    general

    M5a - M5aS

    M5aSF

    Content

    !FaIlUre Or IMPrOPer SeleCTIOn Or IMPrOPer USe OF THe PrODUCTS DeSCrIBeD HereIn Or relaTeD ITeMS Can CaUSe DeaTH, PerSOnal InJUrY anD PrOPerTY DaMage.

    This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.

    The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.

    To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

    Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.

    WARNING – USER RESPONSIBILITY

  • 2 3

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsGeneral Characteristics

    Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    2 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Warning .............................................................................. 2

    General characteristics ....................................................... 3

    Description ......................................................................... 4

    Ports and hydraulic fluids..................................................... 5

    Motor selection ................................................................... 6

    Fluid power formulas .......................................................... 6

    Performance data ............................................................... 7

    Max. ratings ........................................................................ 8

    Technical data .............................................................. 9 - 10

    Ordering code ................................................................... 11

    Motor with side ports - Dimensions .................................. 12

    Motor with opposite ports - Dimensions ........................... 13

    Ordering code ................................................................... 11

    Motor with side ports - Dimensions .................................. 14

    Motor with opposite ports - Dimensions ........................... 15

    general

    M5a - M5aS

    M5aSF

    Content

    !FaIlUre Or IMPrOPer SeleCTIOn Or IMPrOPer USe OF THe PrODUCTS DeSCrIBeD HereIn Or relaTeD ITeMS Can CaUSe DeaTH, PerSOnal InJUrY anD PrOPerTY DaMage.

    This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.

    The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.

    To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

    Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.

    WARNING – USER RESPONSIBILITY

    Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    2 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Warning .............................................................................. 2

    General characteristics ....................................................... 3

    Description ......................................................................... 4

    Ports and hydraulic fluids..................................................... 5

    Motor selection ................................................................... 6

    Fluid power formulas .......................................................... 6

    Performance data ............................................................... 7

    Max. ratings ........................................................................ 8

    Technical data .............................................................. 9 - 10

    Ordering code ................................................................... 11

    Motor with side ports - Dimensions .................................. 12

    Motor with opposite ports - Dimensions ........................... 13

    Ordering code ................................................................... 11

    Motor with side ports - Dimensions .................................. 14

    Motor with opposite ports - Dimensions ........................... 15

    general

    M5a - M5aS

    M5aSF

    Content

    !FaIlUre Or IMPrOPer SeleCTIOn Or IMPrOPer USe OF THe PrODUCTS DeSCrIBeD HereIn Or relaTeD ITeMS Can CaUSe DeaTH, PerSOnal InJUrY anD PrOPerTY DaMage.

    This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise.

    The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.

    To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

    Offer of SalePlease contact your Parker representation for a detailed ”Offer of Sale”.

    WARNING – USER RESPONSIBILITY

    Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    3 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    12 vanes and a patented cartridge design allows a very low noise level, whatever the speed.

    The M5 series have been designed especially for severe duty applications wich require high pressure , high speed and low fluid lubricity.

    Max. pressure (continuous) : 280 barMax. speed (continuous)M5AS* 006 and 010 ................................................... : 5000 rpmM5AS* 012 and 016 ................................................... : 3800 rpmM5AS* 018 ................................................................. : 3300 rpmM5AS* 023 and 025 ................................................... : 2800 rpm

    The high starting torque efficiency of the vane type motors allows them to start under high load without pressure overshoots, jerks and high instantaneous horsepower loads.

    This 12 vane type motor exhibits a very low torque ripple (typical ± 1,5%), even at low speeds.

    The vane, rotor and cam ring are pressure balanced to increase life over the full speed range. Double lip vanes reduce the sensitivity to fluid pollution.

    Our precise manufacturing allows any component to be interchan-geable. Rotating groups may be easily replaced to renew the motor or change the displacement to suit altered requirements for speed or torque.

    The M5AS and M5ASF externally drained, are available in three types of rotation : bi-directional, clockwise, counter-clockwise.

    The uni-directional M5AS, M5ASF are designed with an internal valve that allows smooth dynamic braking, with a very simple hydraulic circuit and without risk of motor cavitation.

    The M5AS, M5ASF motors have a stiff tapered or cylindrical keyed shaft and a high load capacity double ball bearing allow the direct mounting on shaft (like a fan for example).

    For applications with motors in series or with high back pressure, please contact Parker.

    lOW nOISe MOTOr

    HIgH PerFOrManCe MOTOr

    HIgH STarTIng TOrQUe

    lOW TOrQUe rIPPle

    lOng lIFeTIMe

    InTerCHangeaBle rOTaTIng grOUPS

    rOTaTIOn anD DraIn

    CrOSS POrT CHeCK ValVe

    MOUnTIng

    general characteristicsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    3 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    12 vanes and a patented cartridge design allows a very low noise level, whatever the speed.

    The M5 series have been designed especially for severe duty applications wich require high pressure , high speed and low fluid lubricity.

    Max. pressure (continuous) : 280 barMax. speed (continuous)M5AS* 006 and 010 ................................................... : 5000 rpmM5AS* 012 and 016 ................................................... : 3800 rpmM5AS* 018 ................................................................. : 3300 rpmM5AS* 023 and 025 ................................................... : 2800 rpm

    The high starting torque efficiency of the vane type motors allows them to start under high load without pressure overshoots, jerks and high instantaneous horsepower loads.

    This 12 vane type motor exhibits a very low torque ripple (typical ± 1,5%), even at low speeds.

    The vane, rotor and cam ring are pressure balanced to increase life over the full speed range. Double lip vanes reduce the sensitivity to fluid pollution.

    Our precise manufacturing allows any component to be interchan-geable. Rotating groups may be easily replaced to renew the motor or change the displacement to suit altered requirements for speed or torque.

    The M5AS and M5ASF externally drained, are available in three types of rotation : bi-directional, clockwise, counter-clockwise.

    The uni-directional M5AS, M5ASF are designed with an internal valve that allows smooth dynamic braking, with a very simple hydraulic circuit and without risk of motor cavitation.

    The M5AS, M5ASF motors have a stiff tapered or cylindrical keyed shaft and a high load capacity double ball bearing allow the direct mounting on shaft (like a fan for example).

    For applications with motors in series or with high back pressure, please contact Parker.

    lOW nOISe MOTOr

    HIgH PerFOrManCe MOTOr

    HIgH STarTIng TOrQUe

    lOW TOrQUe rIPPle

    lOng lIFeTIMe

    InTerCHangeaBle rOTaTIng grOUPS

    rOTaTIOn anD DraIn

    CrOSS POrT CHeCK ValVe

    MOUnTIng

    general characteristics

  • 4

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors

    5

    DescriptionCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    4 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Description

    • The motor shaft is driven by the rotor. Vanes, closely fitted into the rotor slots move radially to seal against the cam ring. The ring has two major and two minor radial sections joined by transitional sections called ramps. These contours and the pressures exposed to them are balanced diametrically.

    • Light springs urge the vanes radially against the cam contour assuring a seal at zero speed so that the motor can develop starting torque. The springs and pins are assisted by centrifugal force at higher speeds. Radial grooves and holes through the vanes equalize radial hydraulic forces on the vanes at all times. Fluid enters and leaves the motor cartridge through opening in the side plates at the ramps. Each motor port connects to two diametrically opposed ramps. Pressurized fluid entering at Port A torques the rotor clockwise. The rotor transports it to the ramp openings wich connect to Port B from wich it returns to the low pressure side of the system. Pressure at Port B torques the rotor counter-clockwise.

    • The rotor is separated axially from the sideplate surface by the fluid film. The front sideplate is clamped against the cam ring by the pressure, maintains optimum clearance as dimensions change with temperature and pressure. A 3-way shuttle valve in the sideplate causes clamping pressure in Port A or B, whichever is the highest.

    • Materials are chosen for long life efficiency. The vanes, rotor and cam ring are made out of hardened high alloy steels. Cast semi-steel side-plates are chemically etched to have a fine crystalline surface for good lubrification at start-up.

    OPeraTIOn - SIngle CarTrIDge

    Major arc where fluid works to push vane.

    Ramp (port A) with vane moving inward by CW rotation.

    The cam ring is interchangeable with others of different displacement. It has lub coating on inner surface.

    The rotor is of through-hardened high alloy steel.

    The rotation is changed by reversing the flow.

    The side grooves and radial holes causeundervane and overvane pressure to be equal.

    Minor arc where vane works to seal inlet pressure from outlet port.

    Ramp (port B) with vane moving outward by CW rotation.

    The floating sideplate contains a shuttle valve wich passes a higher pressure signal to the

    clamping area.

    The cartridge is a replaceable assembly including the cam ring, rotor, vanes and springs.

    M5aSFM5aS

    Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    4 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Description

    • The motor shaft is driven by the rotor. Vanes, closely fitted into the rotor slots move radially to seal against the cam ring. The ring has two major and two minor radial sections joined by transitional sections called ramps. These contours and the pressures exposed to them are balanced diametrically.

    • Light springs urge the vanes radially against the cam contour assuring a seal at zero speed so that the motor can develop starting torque. The springs and pins are assisted by centrifugal force at higher speeds. Radial grooves and holes through the vanes equalize radial hydraulic forces on the vanes at all times. Fluid enters and leaves the motor cartridge through opening in the side plates at the ramps. Each motor port connects to two diametrically opposed ramps. Pressurized fluid entering at Port A torques the rotor clockwise. The rotor transports it to the ramp openings wich connect to Port B from wich it returns to the low pressure side of the system. Pressure at Port B torques the rotor counter-clockwise.

    • The rotor is separated axially from the sideplate surface by the fluid film. The front sideplate is clamped against the cam ring by the pressure, maintains optimum clearance as dimensions change with temperature and pressure. A 3-way shuttle valve in the sideplate causes clamping pressure in Port A or B, whichever is the highest.

    • Materials are chosen for long life efficiency. The vanes, rotor and cam ring are made out of hardened high alloy steels. Cast semi-steel side-plates are chemically etched to have a fine crystalline surface for good lubrification at start-up.

    OPeraTIOn - SIngle CarTrIDge

    Major arc where fluid works to push vane.

    Ramp (port A) with vane moving inward by CW rotation.

    The cam ring is interchangeable with others of different displacement. It has lub coating on inner surface.

    The rotor is of through-hardened high alloy steel.

    The rotation is changed by reversing the flow.

    The side grooves and radial holes causeundervane and overvane pressure to be equal.

    Minor arc where vane works to seal inlet pressure from outlet port.

    Ramp (port B) with vane moving outward by CW rotation.

    The floating sideplate contains a shuttle valve wich passes a higher pressure signal to the

    clamping area.

    The cartridge is a replaceable assembly including the cam ring, rotor, vanes and springs.

    M5aSFM5aS

    Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    4 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Description

    • The motor shaft is driven by the rotor. Vanes, closely fitted into the rotor slots move radially to seal against the cam ring. The ring has two major and two minor radial sections joined by transitional sections called ramps. These contours and the pressures exposed to them are balanced diametrically.

    • Light springs urge the vanes radially against the cam contour assuring a seal at zero speed so that the motor can develop starting torque. The springs and pins are assisted by centrifugal force at higher speeds. Radial grooves and holes through the vanes equalize radial hydraulic forces on the vanes at all times. Fluid enters and leaves the motor cartridge through opening in the side plates at the ramps. Each motor port connects to two diametrically opposed ramps. Pressurized fluid entering at Port A torques the rotor clockwise. The rotor transports it to the ramp openings wich connect to Port B from wich it returns to the low pressure side of the system. Pressure at Port B torques the rotor counter-clockwise.

    • The rotor is separated axially from the sideplate surface by the fluid film. The front sideplate is clamped against the cam ring by the pressure, maintains optimum clearance as dimensions change with temperature and pressure. A 3-way shuttle valve in the sideplate causes clamping pressure in Port A or B, whichever is the highest.

    • Materials are chosen for long life efficiency. The vanes, rotor and cam ring are made out of hardened high alloy steels. Cast semi-steel side-plates are chemically etched to have a fine crystalline surface for good lubrification at start-up.

    OPeraTIOn - SIngle CarTrIDge

    Major arc where fluid works to push vane.

    Ramp (port A) with vane moving inward by CW rotation.

    The cam ring is interchangeable with others of different displacement. It has lub coating on inner surface.

    The rotor is of through-hardened high alloy steel.

    The rotation is changed by reversing the flow.

    The side grooves and radial holes causeundervane and overvane pressure to be equal.

    Minor arc where vane works to seal inlet pressure from outlet port.

    Ramp (port B) with vane moving outward by CW rotation.

    The floating sideplate contains a shuttle valve wich passes a higher pressure signal to the

    clamping area.

    The cartridge is a replaceable assembly including the cam ring, rotor, vanes and springs.

    M5aSFM5aS

  • 4 5

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsPorts and Hydraulic FluidsCatalogue HY29-0024/UK Hydraulic Motors, Fixed

    M5AS/M5ASF, Denison Vane Motors

    5 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Ports and hydraulic fluids

    This motor must have a drain line connected to the housing drain connection of sufficient size to prevent back pressure in excess of 3,5 bar, and returned to the reservoir below the surface of the oil as far away as possible from the suction pipe of the pump.

    Petroleum base anti-wear R & O fluids (covered by Parker Denison HF-0 and HF-2 specifications).Maximum catalogue ratings and performance data are based on operation with these fluids.

    The use of fluids other than petroleum base anti-wear R & O fluids requires that the maximum ratings of the motor will be reduced. In some cases, the minimum replenishment pressure must be increased.

    HF-1 : non antiwear petroleum base.HF-4 : water glycols solutions.HF-5 : synthetic fluids.

    Max. continuous pressure : 210 bar (HF-1, HF-4, HF-5)Max. speed : 1500 RPM (HF-4, HF-5)

    Max. (cold start, low speed and pressure) 2000 mm2/s (cSt)Max. (full speed and pressure) 100 mm2/s (cSt)Optimum (max. lifetime) 30 mm2/s (cSt)Min. (full speed and pressure, HF-1 fluid) 18 mm2/s (cSt)Min. (full speed and pressure, HF-0 & HF-2 fluids) 10 mm2/s (cSt)For cold starts, the motor should operate at low speed and pressure until fluid warms up to an acceptable viscosity for full power operation.

    90 min.Higher values extend the range of operating temperatures and lifetime.

    Max. fluid temperature (HF-0, HF-1 & HF-2) + 100° CMin. fluid temperature (HF-0, HF-1 & HF-2) - 18° C

    The fluid must be cleaned before and during operation to maintain a contamination level of NAS 1638 class 8 (or ISO 19/17/14) or better. Filters with 25 micron (or bet-ter, ß10 ≥ 100) nominal ratings may be adequate but do not guarantee the required cleanliness levels.

    Maximum acceptable content of water is :• 0,10 % for mineral base fluids.• 0,05 % for synthetic fluids, crankcase oils, biodegradable fluids.If amount of water is higher, then it should be drained off the circuit.

    exTernal DraIn

    reCOMMenDeD FlUIDS

    aCCePTaBle alTernaTe FlUIDS

    VISCOSITY

    VISCOSITY InDex

    TeMPeraTUre

    FlUID CleanlIneSS

    WaTer COnTaMInaTIOn In FlUID

    Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    5 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Ports and hydraulic fluids

    This motor must have a drain line connected to the housing drain connection of sufficient size to prevent back pressure in excess of 3,5 bar, and returned to the reservoir below the surface of the oil as far away as possible from the suction pipe of the pump.

    Petroleum base anti-wear R & O fluids (covered by Parker Denison HF-0 and HF-2 specifications).Maximum catalogue ratings and performance data are based on operation with these fluids.

    The use of fluids other than petroleum base anti-wear R & O fluids requires that the maximum ratings of the motor will be reduced. In some cases, the minimum replenishment pressure must be increased.

    HF-1 : non antiwear petroleum base.HF-4 : water glycols solutions.HF-5 : synthetic fluids.

    Max. continuous pressure : 210 bar (HF-1, HF-4, HF-5)Max. speed : 1500 RPM (HF-4, HF-5)

    Max. (cold start, low speed and pressure) 2000 mm2/s (cSt)Max. (full speed and pressure) 100 mm2/s (cSt)Optimum (max. lifetime) 30 mm2/s (cSt)Min. (full speed and pressure, HF-1 fluid) 18 mm2/s (cSt)Min. (full speed and pressure, HF-0 & HF-2 fluids) 10 mm2/s (cSt)For cold starts, the motor should operate at low speed and pressure until fluid warms up to an acceptable viscosity for full power operation.

    90 min.Higher values extend the range of operating temperatures and lifetime.

    Max. fluid temperature (HF-0, HF-1 & HF-2) + 100° CMin. fluid temperature (HF-0, HF-1 & HF-2) - 18° C

    The fluid must be cleaned before and during operation to maintain a contamination level of NAS 1638 class 8 (or ISO 19/17/14) or better. Filters with 25 micron (or bet-ter, ß10 ≥ 100) nominal ratings may be adequate but do not guarantee the required cleanliness levels.

    Maximum acceptable content of water is :• 0,10 % for mineral base fluids.• 0,05 % for synthetic fluids, crankcase oils, biodegradable fluids.If amount of water is higher, then it should be drained off the circuit.

    exTernal DraIn

    reCOMMenDeD FlUIDS

    aCCePTaBle alTernaTe FlUIDS

    VISCOSITY

    VISCOSITY InDex

    TeMPeraTUre

    FlUID CleanlIneSS

    WaTer COnTaMInaTIOn In FlUID

  • 6

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors

    7

    Motor SelectionCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    6 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Motor Selection

    0,85 x >

    10,6 > 8,7 kW

    2a.

    Vi = = = 13,8 cm3/rev

    3a. Choose motor from Vi immediately greaterM5AS* 016 : Vi = 16,0 cm

    3/rev

    4a. Check theoretical motor pressure

    D p = = = 216 bar

    Torque loss at this pressure = 3,0 Nm(See page 9)Calculate real pressure

    D peff. = = = 228 bar

    5a. Flow loss at this pressure : 3,5 l/min(See page 9)Real flow used by the motor :Qeff. = 30 - 3,5 = 26,5 l/min

    6a. Real speed of the motor :

    neff. = = = 1656 rpm

    Real performancesVi = 16,0 cm

    3/revneff. = 1656 rpmT = 55 Nm.D peff. = 228 bar

    0.85 x >

    2b.

    Vi = = = 20,0 cm3/rev

    3b. Choose motor from Vi immediately smallerM5AS* 018 : Vi = 18,0 cm

    3/rev

    4b. Check theoretical motor pressure withT = 55 Nm

    D p = = = 192 bar

    Torque loss at this pressure = 3,3 Nm(See page 9)Calculate real pressure

    D peff. = = = 204 bar

    5b. Flow loss at this pressure : 4 l/min(See page 9)Real flow used by the motor :Qeff. = 30 - 4 = 26,0 l/min

    6b. Real speed of the motor:

    neff. = = = 1444 rpm

    Real performancesVi = 18,0 cm

    3/revneff. = 1444 rpmM = 55 Nm.D peff. = 204 bar

    Q x p 600

    1000 x 30 1500

    Motor performances requiredTorque ....................... T [Nm.] 55Speed ....................... n [rpm] 1500Pump available data Flow .......................... Q [l/min] 30D Pressure ................ D p [bar] 250

    FlUID POWer FOrMUlaS

    Volumetric efficiency

    Mechanical efficiency

    Fluid motor speed rpm

    Fluid motor torque N.m

    Fluid motor power kW

    1. Check if available power is greater than required power (0.85 estimated overall efficiency).

    T x p x n30 x 1000

    2. Two ways of calculation : Calculate Vi from T required torque, or from Q available flow.

    30 x 250 600

    55 x p x 1500 30 x 1000

    20 x p x T p

    20 x p x 55 250

    1000 x Q n

    20 x p x T Vi

    20 x p x 55 16,0

    20 x p x (T + Tl) Vi

    20 x p x 58 16,0

    Qeff. x 1000 Vi

    26,5 x 1000 16,0

    20 x p x T Vi

    20 x p x 55 18,0

    20 x p x (T + Tl) Vi

    20 x p x 58,3 18,0

    Qeff. x 1000 Vi.

    26,0 x 1000 18,0

    Speed [rpm]Displacement [cm3/rev]Pressure [bar]Flow rate [l/min]Leakage [l/min]Torque [Nm]Torque loss [Nm]

    1 total leakage x 1000 speed x displacement

    torque loss x 20 x p D pressure x displacement

    1000 x flow rate x volumetric eff. displacement

    D pressure x displacement x mech. eff. 20 x p

    speed x displacement x D pressure x overall eff. or 600 000

    1 +

    1 -

    torque x speed x 20 x p 600 000

  • 6 7

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsPerformance DataCatalogue HY29-0024/UK Hydraulic Motors, Fixed

    M5AS/M5ASF, Denison Vane Motors

    7 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Performance Data

    SeriesTheoretical

    Displacement Vi

    Theoreticaltorque

    Theoretical powerat 100 rpm

    Typical dataat 2000 rpm - 280 bar

    cm3/rev n.m/bar kW/bar n.m kW

    M5aM5aSM5aSF

    6,3 0,100 0,0011 24,4 5,110,0 0,159 0,0017 40,8 8,612,5 0,199 0,0021 52,0 10,916,0 0,255 0,0027 67,6 14,218,0 0,286 0,0030 75,8 15,923,0 0,366 0,0038 98,4 20,425,0 0,398 0,0042 107,4 22,5

    STarTIng PerFOrManCeS

    PerMISSIBle SHaFT lOaDS

    Mounting flange Threaded port a Threaded port B Threaded drain port Shaft end

    M5a Uni-rotational 2-bolts

    ISO 3019-2 80 A2 HW

    M22 x 1,5 M27 x 2 M12 x 1,5

    Taper 1/5Keyed ISO G20N

    M5a Bi-rotational

    M22 x 1,5 M12 x 1,5

    M5aS Uni-rotational 2-bolts

    SAE AJ744

    SAE 10 - (7/8"-14 UNF)1/2" BSPP

    SAE 12 - (1.1/16"-12 UNF)3/4" BSPP

    SAE 6 - (9/16" -18 UNF)1/4" BSPP

    Taper SAE BKeyed SAE B

    Taper 1/5Keyed ISO G20NM5aS

    Bi-rotationalSAE 12 - (1.1/16"-12 UNF)

    3/4" BSPPSAE 6 - (9/16"-18 UNF)

    1/4" BSPP

    M5aSF Uni-rotational

    2-boltsØ 101,6 h8cartridge /

    outrigger bearing version

    M22 x 1,5SAE 10 - (7/8"-14 UNF)

    1/2" BSPP

    M27 x 2SAE 12 - (1.1/16"-12 UNF)

    3/4" BSPP

    M12 x 1,5SAE 6 - (9/16"-18 UNF)

    1/4" BSPPTaper SAE BKeyed SAE B

    Taper 1/5Keyed ISO G20NM5aSF

    Bi-rotational

    M22 x 1,5SAE 12 - (1.1/16"-12 UNF)

    3/4" BSPP

    M12 x 1,5SAE 6 - (9/16"-18 UNF)

    1/4" BSPP

    Theoretical lifetime [106 rev] : L10

    Theoretical lifetime [Hours] : L10H = x L10

    Example of theoretical lifetime calculationAxial load Fa = 1000 NRadial load Fr = 500 NMotor speed N = 1500 rpm

    L10 = 2000 [106 rev] (See Curve)

    L10H = x 2000 L10H = 22 221 hours.

    16 666N [min-1]

    16 666 1500

    Typical data at 24 cSt @ 45° C Maximum cross flow 100 bar : 0,6 l/min 200 bar : 7,4 l/min 280 bar : 8,9 l/min

    0

    500

    1000

    1500

    2000

    2500

    0 500 1000 1500 2000 2500 3000

    Fa (N)

    Fr

    (N)

    L10 = 250L10 = 500L10 = 1000L10 = 2000

    Axial load Fa [N]

    Theoretical lifetime [106 rev]

    Rad

    ial l

    oad

    Fr [N

    ]

    x x

    Fr

    Fa

  • 8

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors

    9

    Max RatingsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    8 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Max ratingsMax ratings M5AS 010 & 006

    0

    50

    100

    150

    200

    250

    300

    0 1000 2000 3000 4000 5000 6000 7000

    Operating speed n (RPM)

    Pres

    sure

    p (b

    ar)

    continuous

    intermittent

    Max ratings M5AS 016 & 012

    0

    50

    100

    150

    200

    250

    300

    0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000

    Operating speed n (RPM)

    Pres

    sure

    p (b

    ar)

    continuous

    intermittent

    Max ratings M5AS 018

    0

    50

    100

    150

    200

    250

    300

    0 500 1000 1500 2000 2500 3000 3500 4000 4500

    Operating speed n (RPM)

    Pres

    sure

    p (b

    ar)

    continuous

    intermittent

    D:\Catalogues Vente\M5ASVente\Anglais\Limitations M5AS.xls 18/02/2010

    Max ratings M5AS 025 & 023

    0

    50

    100

    150

    200

    250

    300

    0 500 1000 1500 2000 2500 3000 3500

    Operating speed n (RPM)

    Pres

    sure

    p (b

    ar)

    continuous

    intermittent

    006 - 010

    012 - 016

    018

    023 - 025

    Operating speed n [rpm]

    Operating speed n [rpm]

    Operating speed n [rpm]

    Operating speed n [rpm]

    Pre

    ssur

    e p

    [bar

    ]P

    ress

    ure

    p [b

    ar]

    Pre

    ssur

    e p

    [bar

    ]P

    ress

    ure

    p [b

    ar]

    - These are running condition limits; for starting performances see page 7.- Typical curves, at 24 cSt @ 45° C.- For higher specifications or for operating speed under < 100 rpm, please consult us.

    Continuous Intermittent

    Continuous Intermittent

    Continuous Intermittent

    Continuous Intermittent

  • 8 9

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsTechnical Data

    Catalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    9 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    Technical data

    OVerall leaKage (internal + external) TOrQUe lOSSfuite totale M5A 010 @1500 tr/min

    1,0

    2,0

    3,0

    4,0

    5,0

    6,0

    - 50 100 150 200 250

    p (bar)

    fuite

    tota

    le (

    l/min

    )

    13 cSt26 cSt50 cSt

    fuite totale M5A 023 @1500 tr/min

    1,0

    2,0

    3,0

    4,0

    5,0

    6,0

    7,0

    8,0

    9,0

    50 100 150 200 250

    p (bar)

    fuite

    tota

    le (

    l/min

    )

    13 cSt26 cSt50 cSt

    fuite totale M5A 012 @1500 tr/min

    1,0

    2,0

    3,0

    4,0

    5,0

    6,0

    7,0

    8,0

    - 50 100 150 200 250

    p (bar)

    fuite

    tota

    le (

    l/min

    )

    13 cSt26 cSt50 cSt

    fuite totale M5A 025 @1500 tr/min

    1,0

    2,0

    3,0

    4,0

    5,0

    6,0

    7,0

    8,0

    9,0

    10,0

    - 50 100 150 200 250

    p (bar)

    fuite

    tota

    le (l

    /min

    )

    13 cSt26 cSt50 cSt

    perte de couple M5A 010 @1500 tr/min

    0,5

    1,0

    1,5

    2,0

    2,5

    3,0

    3,5

    - 50 100 150 200 250

    p (bar)

    pert

    e de

    cou

    ple

    (Nm

    )

    13 cSt26 cSt50 cSt

    perte de couple M5A 018 @1500 tr/min

    0,5

    1,0

    1,5

    2,0

    2,5

    3,0

    3,5

    4,0

    4,5

    5,0

    - 50 100 150 200 250

    p (bar)

    pert

    e de

    cou

    ple

    (Nm

    )

    13 cSt26 cSt50 cSt

    perte de couple M5A 012 @1500 tr/min

    0,5

    1,0

    1,5

    2,0

    2,5

    3,0

    3,5

    4,0

    4,5

    - 50 100 150 200 250

    p (bar)

    pert

    e de

    cou

    ple

    (Nm

    )

    13 cSt26 cSt50 cSt

    perte de couple M5A 023 @1500 tr/min

    0,5

    1,0

    1,5

    2,0

    2,5

    3,0

    3,5

    4,0

    4,5

    5,0

    5,5

    50 100 150 200 250

    p (bar)

    pert

    e de

    cou

    ple

    (Nm

    )

    13 cSt26 cSt50 cSt

    Pressure p [bar]

    Pressure p [bar]

    Pressure p [bar]

    Pressure p [bar]

    Pressure p [bar]

    Pressure p [bar]

    Pressure p [bar]

    Pressure p [bar]

    Ove

    rall

    leak

    age

    Qlo

    ss [l

    /min

    ]O

    vera

    ll le

    akag

    e Q

    loss

    [l/m

    in]

    Ove

    rall

    leak

    age

    Qlo

    ss [l

    /min

    ]O

    vera

    ll le

    akag

    e Q

    loss

    [l/m

    in]

    Torq

    ue lo

    ss T

    loss

    [Nm

    ]To

    rque

    loss

    Tlo

    ss [N

    m]

    Torq

    ue lo

    ss T

    loss

    [Nm

    ]To

    rque

    loss

    Tlo

    ss [N

    m]

    M5A* - 006 and 010@ n = 1500 rpm

    M5A* - 006 and 010@ n = 1500 rpm

    M5A* - 012 and 016 @ n = 1500 rpm

    M5A* - 012 and 016 @ n = 1500 rpm

    M5A* - 018 @ n = 1500 rpm

    M5A* - 018 @ n = 1500 rpm

    M5A* - 023 and 025 @ n = 1500 rpm

    M5A* - 023 and 025 @ n = 1500 rpm

  • 10

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors

    11

    Technical DataCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    10 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    nOISe leVelM5AS 025 Noise Level M5AS 025

    50

    55

    60

    65

    70

    75

    80

    0 50 100 150 200 250 300Pressure p (bar)

    LP N

    oise

    leve

    l [dB

    (A)]

    500 RPM

    1000 RPM

    1500 RPM

    2000 RPM

    500 rpm 1000 rpm 1500 rpm 2000 rpm

    Lp. N

    oise

    leve

    l [db

    (A)]

    1m IS

    O 4

    412

    Pressure p [bar]

    Technical data

    A B

    Uni-rotationnel+ Anti-starve

    OPTIOn FOr M5aS - M5aSF UnI-rOTaTIOnal MOTOrS : anTI STarVe ValVe

    An anti-starve check valve can be screwed directly onto the B port of the uni-rotational motors, to ensure the minimum replenishment pressure during deceleration phases of high inertia systems (i.e. fan drive).

    MInIMUM rePlenISHMenT PreSSUreDUrIng DeCeleraTIOn

    Minimum Outlet port pressure for uni-rotationnal motors

    Oil Azolla ZS32 T=45°C (26 cSt)

    0

    1

    2

    3

    4

    5

    6

    7

    0 10 20 30 40 50 60 70 80 90 100Q [l/min]

    P [b

    ar]

    Pre

    ssur

    e p

    [bar

    ] Abs

    olut

    e

    B g A [l/min]

    ISO VG 32 @ 45°C

    The hydraulic circuit should be designed in a way that when switching off the hydraulic motor, it remains supplied with fluid, without risk of cavitation (anti-cavitation valve may be needed).Uni rotational M5AS* Motors are fitted with an internal anti-cavitation valve.

    necessary pressure [bar absolute] at B port of M5aS* uni-rotational during deceleration

    View from shaft end : CW rotation A = inlet B = outlet CCW rotation A = outlet B = inlet

    BI-rOTaTIOnal (n)

    r Or l rOTaTIOn new rotation concept - (Patent pending) :

    View from shaft end : CW or CCW rotations A = inlet B = outlet

    R or L rotation are featuring a new internal concept where A is always “in” and B is always “out”.

    A BA B A BA B+lennoitator-inUlennoitator-inUlennoitator-iB

    LP proportionnalUni-rotationnel + LP

    A BA B A BA B+lennoitator-inUlennoitator-inUlennoitator-iB

    LP proportionnalUni-rotationnel + LP

    with pressure relief valvewith prop. pressure

    relief valve

    Parker DT series check valves

    Ex : for SAE 12 treads DT - 750 - MOMF - 65 DT - 75 - MOMS - 65

    M5AS - 025

    F L O W

  • 10 11

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsM5AS - Ordering CodeCatalogue HY29-0024/UK Hydraulic Motors, Fixed

    M5AS/M5ASF, Denison Vane Motors

    11 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    M5AS - Ordering code

    DRAINA

    B

    DRAIN

    BA

    DRAIN

    B A

    DRAINB

    A

    DRAIN A

    B01 02 03 04

    DrainDrain

    DrainDrain

    Drain

    1 2 3 4

    end cap = 0

    01 02 03 04

    A BDRAIN

    DRAIN DRAIN DRAINDRAINA B

    B

    A

    B A

    A

    B

    1 2 3 4

    Drain Drain Drain Drain

    Drain

    end cap = 1

    Model no. M5aS - 018 - 1 n 0 2 - a 1 W - P21

    Model no. M5aSF - 018 - 1 n 0 2 - a 1 W - P21

    M5a series - ISO 3019-2Mounting flange 80 A2 SWM5aS series - SAE A 2-boltsJ744 mounting flange

    Cam ringVolumetric displacement (ml/rev)006 = 6,3 018 = 18,0010 = 10,0 023 = 23,0012 = 12,5 025 = 25,0016 = 16,0

    Type of shaft M5aS1 = Taper (Sae B)2 = Keyed (SAE B)Type of shaft M5a or M5aS 5 = Taper 1/56 = Keyed (ISO G20N)

    Direction of rotation (shaft end view)R = Clockwise (with anti-cavitation check valve)L = Counter-clockwise (with anti-cavitation check valve)N = Bi-rotational (without anti-cavitation check Valve)

    end cap type0 = with opposite ports1 = with side ports

    Porting combination(See table)

    M5aSF - 2-bolts flangeØ 101,6 h8

    Cam ringVolumetric displacement (ml/rev)006 = 6,3 018 = 18,0010 = 10,0 023 = 23,0012 = 12,5 025 = 25,0016 = 16,0

    Type of shaft1 = Taper (Sae B)2 = Keyed (SAE B)5 = Taper 1/56 = Keyed (ISO G20N)

    Direction of rotation (shaft end view)R = Clockwise (with anti-cavitation check valve)L = Counter-clockwise (with anti-cavitation check valve)N = Bi-rotational (without anti-cavitation check Valve)

    end cap type0 = with opposite ports1 = with side ports

    Porting combination(See table)

    Modifications or special optionEx. : P21 = Proportional pressure relief valveset at 210 bar at 1000 rpm

    end cap variables

    M5a bi-rotational seriesCode A & B ports Drain port

    Y Metric threadM22 x 1,5Metric thread

    M12 x 1,5

    M5a uni-rotational seriesCode A port B port Drain port

    Y Metric threadM22 x 1,5Metric thread

    M27 x 2Metric thread

    M12 x 1,5

    M5aS bi-rotational seriesCode A & B ports Drain Port

    W Sae 12 thread1.1/16"-12 UnFSae 6 thread9/16"-18 UnF

    Z 3/4" BSPP 1/4" BSPP

    M5aS uni-rotational seriesCode A port B port Drain port

    W Sae 10 thread7/8"-14 UnFSae 12 thread1.1/16"-12 UnF

    Sae 6 thread9/16"-18 UnF

    Z 1/2" BSPP 3/4" BSPP 1/4" BSPP

    Seal class1 = S1 BUNA N5 = S5 - VITON®

    Design letter

    Modifications or special optionEx. : P21 = Proportional pressure relief valveset at 210 bar at 1000 rpm

    end cap variables

    M5aSF bi-rotational seriesCode A & B ports Drain port

    Y Metric threadM22 x 1,5Metric thread

    M12 x 1,5

    W Sae 12 thread1.1/16"-12 UnFSae 6 thread9/16"-18 UnF

    Z 3/4" BSPP 1/4" BSPP

    M5aSF uni-rotational seriesCode A port B port Drain port

    Y Metric threadM22 x 1,5Metric thread

    M27 x 2Metric thread

    M12 x 1,5

    W Sae 10 thread7/8"-14 UnFSae 12 thread1.1/16"-12 UnF

    Sae 6 thread9/16"-18 UnF

    Z 1/2" BSPP 3/4" BSPP 1/4" BSPP

    Seal class1 = S1 BUNA N5 = S5 - VITON®

    Design letter

    Preferred types are printed in bold.

  • 12

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors

    13

    M5A - M5AS - DimensionsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    12 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    M5A - M5AS - Dimensions Motor with side ports

    Weight : 12,2 kg

    TH

    RE

    AD

    ED

    DR

    AIN

    PO

    RT

    :2:

    SA

    E 6

    3:

    M12

    x 1

    ,5

    4: 1

    /4"

    BS

    PP

    Mou

    ntin

    g to

    rque

    100

    N.m

    Ø 22,220

    -0.25

    Pre

    ssur

    e re

    lief v

    alve

    12

    14 M x 1,5

    Ø 20-0.065-0.117 �

    2

    TH

    RE

    AD

    ED

    PO

    RT

    SW

    : SA

    E 1

    2 Y:

    M22

    x 1

    ,5

    Z: 3

    /4"

    BS

    PP

    83,8

    4 x

    6 ke

    y

    110

    55

    55

    113,4

    15,8

    8

    3,45

    6,35

    key

    squ

    are

    Ø 4

    47,7

    "A"

    INLE

    T T

    HR

    EA

    DE

    D P

    OR

    TW

    : SA

    E 1

    0 Y:

    M22

    x 1

    ,5

    Z: 1

    /2"

    BS

    PP

    "B"

    OU

    TLE

    T T

    HR

    EA

    DE

    D P

    OR

    TW

    : SA

    E 1

    2 Y:

    M27

    x 2

    Z

    : 3/4

    " B

    SP

    P

    95

    Un

    i-ro

    tati

    on

    al ve

    rsio

    n58,6

    7+0

    .5 0M

    5A:

    M5A

    S: 6

    .4

    Ø 82,550-0.05 M5AS: �

    M5A: � Ø 80 h8

    10

    5,5

    13

    0,4

    �Ø 11(2 places)

    134,87

    41,5 28

    ,6

    65,4

    118,

    2

    151,

    6

    28,6

    19,2

    8

    44

    8 MKey

    squ

    are

    6h9

    28

    16

    Ø 20 �j7

    22,5

    8

    41

    8 M

    16

    23,5

    Ø 22,2+0.0250 �ke

    y sq

    uare

    6,3

    5

    24,94Maxi

    24 V

    DC

    coi

    l to

    be

    conn

    ecte

    d w

    ith

    Deu

    tsch

    DT

    06-2

    S c

    onne

    ctor

    Pro

    port

    iona

    l pre

    ssur

    ere

    lief v

    alve

    Sha

    ft c

    ode

    5K

    eyed

    tape

    r 1:

    5

    Sha

    ft c

    ode

    1S

    AE

    B -

    J74

    4 (m

    odifi

    ed)

    Tape

    r 12

    5:10

    00

    Sha

    ft c

    ode

    2S

    AE

    B k

    eyed

    Sha

    ft c

    ode

    6IS

    O G

    20N

    key

    ed

  • 12 13

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsM5A - M5AS - DimensionsCatalogue HY29-0024/UK Hydraulic Motors, Fixed

    M5AS/M5ASF, Denison Vane Motors

    13 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    TH

    RE

    AD

    ED

    DR

    AIN

    PO

    RT:

    2: S

    AE

    6

    3: M

    12 x

    1,5

    4:

    1/4

    " B

    SP

    P

    Mou

    ntin

    g to

    rque

    100

    N.m

    Ø 22,220

    -0.25

    12

    14 M x 1,5

    20-0.065-0.117 Ø �

    2

    Sha

    ft c

    ode

    5K

    eyed

    tape

    r 1:

    5

    TH

    RE

    AD

    ED

    PO

    RT

    SW

    : SA

    E 1

    2 Y:

    M22

    x 1

    ,5

    Z: 3

    /4"

    BS

    PP

    4 x

    6 ke

    y

    110

    55

    55

    15,8

    8

    3,45

    6,35

    key

    squ

    are

    �Ø

    4

    47,7

    58,6

    7+0

    .5 0M

    5A:

    M5A

    S: 6

    .4

    82,550-0.05 M5AS: Ø

    M5A: Ø 80 h8

    105,

    5

    130,

    4

    �Ø 11(2 places)

    39 28,

    6

    65,4

    120,

    7

    130,

    5

    73 80

    137,

    7

    Uni-r

    ota

    tional v

    ers

    ion

    "A"

    INLE

    T T

    HR

    EA

    DE

    D P

    OR

    TW

    : SA

    E 1

    0 Y:

    M22

    x 1

    ,5

    Z: 1

    /2"

    BS

    PP

    "B"

    OU

    TLE

    T T

    HR

    EA

    DE

    D P

    OR

    TW

    : SA

    E 1

    2 Y:

    M27

    x 2

    Z:

    3/4

    " B

    SP

    P

    Pre

    ssur

    e re

    lief v

    alve

    Pro

    port

    ionn

    al p

    ress

    ure

    relie

    f val

    ve

    109

    28,6

    8

    44

    8 MKey

    squ

    are

    6 h9

    28

    16

    Ø 20 �j7

    22,5

    8

    41

    8 M

    16

    23,5

    22,2+0.0250 �ke

    y sq

    uare

    6,3

    5

    24,94Maxi

    24 V

    DC

    coi

    l to

    be

    conn

    ecte

    d w

    ith

    Deu

    tsch

    DT

    06-2

    S c

    onne

    ctor

    Sha

    ft c

    ode

    1S

    AE

    B -

    J744

    (mod

    ified

    )Ta

    per 1

    25:1

    000

    Sha

    ft c

    ode

    2S

    AE

    B k

    eyed

    Sha

    ft c

    ode

    6IS

    O G

    20N

    key

    ed

    M5A - M5AS - Dimensions Motor with opposite ports

    Weight : 11,2 kg

  • 14

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane Motors

    15

    M5ASF - DimensionsCatalogue HY29-0024/UK Hydraulic Motors, Fixed M5AS/M5ASF, Denison Vane Motors

    14 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    M5ASF - Dimensions Motor with side ports

    Weight : 11,5 kg

    TH

    RE

    AD

    ED

    DR

    AIN

    PO

    RT

    :2:

    SA

    E 6

    3:

    M12

    x 1

    ,5

    4: 1

    /4"

    BS

    PP

    Mou

    ntin

    g to

    rque

    100

    N.m

    19

    Ø 101,6 �h8

    12,9

    12

    56,5

    7,4

    36

    Ø 22,22

    0-0.25 �

    68

    59

    Pre

    ssur

    e re

    lief v

    alve

    2,4

    19,2

    44,9

    12

    14 M x 1,5

    Ø 20-0.065-0.117 �

    2

    Ø 22,2+0.0250 �

    24,94 Maxi

    23,5

    key

    squa

    re 6

    ,35

    1,6

    33

    TH

    RE

    AD

    ED

    PO

    RT

    SW

    : SA

    E 1

    2 Y

    : M22

    x 1

    ,5

    Z: 3

    /4"

    BS

    PP

    83,8

    4 x

    6 ke

    y

    Pro

    port

    iona

    l pre

    ssur

    e re

    lief v

    alve

    67,2

    110

    55

    55

    113,4

    146

    73

    162,

    74

    81,3

    7

    �Ø 14,3

    134,9

    15,8

    8

    3 , 45

    6,35

    key

    squ

    are

    �Ø

    4

    47,7

    "A"

    INLE

    T T

    HR

    EA

    DE

    D P

    OR

    TW

    : SA

    E 1

    0 Y

    : M22

    x 1

    ,5Z

    : 1/2

    " B

    SP

    P

    "B"

    OU

    TLE

    T T

    HR

    EA

    DE

    D P

    OR

    TW

    : SA

    E 1

    2 Y

    : M27

    x 2

    Z

    : 3/4

    " B

    SP

    P

    100,

    6

    95

    95

    Un

    i-ro

    tati

    on

    al V

    ers

    ion

    key

    squa

    re 6

    h9

    Ø 20 �j7

    28

    M8

    16

    M8

    16

    22,5

    1,6

    36

    24 V

    DC

    coi

    l to

    be

    conn

    ecte

    d w

    ith

    Deu

    tsch

    DT

    06-2

    S c

    onne

    ctor

    Shaft

    code 1

    SA

    E B

    - J

    744

    (mod

    ified

    )Ta

    per

    125:

    1000

    Shaft

    code 2

    SA

    E B

    key

    edS

    haft

    code 6

    ISO

    G20

    N k

    eyed

    Shaft

    code 5

    Key

    ed ta

    per

    1:5

  • 14 15

    Parker Hannifin CorporationHydraulic Pump DivisionMarysville, Ohio USA

    Catalog HY29-0024/US Hydraulic Motors, FixedM5AS/M5ASF, Denison Vane MotorsM5ASF - DimensionsCatalogue HY29-0024/UK Hydraulic Motors, Fixed

    M5AS/M5ASF, Denison Vane Motors

    15 Parker Hannifin SASVPDE, Denison Vane MotorsVierzon - France

    TH

    RE

    AD

    ED

    PO

    RT

    SW

    : SA

    E 1

    2 Y:

    M22

    x 1

    ,5

    Z: 3

    /4"

    BS

    PP

    TH

    RE

    AD

    ED

    DR

    AIN

    PO

    RT

    :2:

    SA

    E 6

    3:

    M12

    x 1

    ,5

    4: 1

    /4"

    BS

    PP

    Mou

    ntin

    g to

    rque

    100

    N.m

    86,7

    19

    64,2

    Ø 101,6 �h8

    80 73

    12,9 12

    56,5

    7,4

    36

    Ø 22,220-0.25

    16 M x 1,5

    68

    59

    Pro

    port

    iona

    l pre

    ssur

    e re

    lief v

    alve

    109,

    4

    146

    73

    162,

    74

    81,3

    711

    0

    55

    Pre

    ssur

    e re

    lief v

    alve

    110

    55

    �Ø 14,32,

    419

    ,2

    44,9

    12

    14 M x 1,5

    Ø 20-0.065-0.117 �

    2

    Ø 22,2+0.0250

    24,94 Maxi

    23,5

    key

    squa

    re 6

    ,35

    138

    ,5

    1,6

    33

    4 x

    6 ke

    y

    "A"

    INLE

    T T

    HR

    EA

    DE

    D P

    OR

    TW

    : SA

    E 1

    0 Y:

    M22

    x 1

    ,5

    Z: 1

    /2"

    BS

    PP

    "B"

    OU

    TLE

    T T

    HR

    EA

    DE

    D P

    OR

    TW

    : SA

    E 1

    2 Y:

    M27

    x 2

    Z

    : 3/4

    " B

    SP

    P

    key

    squa

    re 6

    h9

    Ø 20 �j7

    28

    M8

    16

    22,5

    1,6

    36

    � Ø 4

    15,8

    8

    6,35

    key

    squ

    are

    24 V

    DC

    coi

    l to

    be

    conn

    ecte

    d w

    ith

    Deu

    tsch

    DT

    06-2

    S c

    onne

    ctor

    Sha

    ft c

    ode

    5K

    eyed

    tape

    r 1:

    5

    Uni-ro

    tati

    onal ve

    rsio

    nS

    haft

    code

    1S

    AE

    B -

    J74

    4 (m

    odifi

    ed)

    Tape

    r 12

    5:10

    00

    Sha

    ft c

    ode

    2S

    AE

    B k

    eyed

    Sha

    ft c

    ode

    6IS

    O G

    20N

    key

    ed

    M5ASF - Dimensions Motor with opposite ports

    Weight : 10,5 kg

  • © 2012 Parker Hannifin Corporation, all rights reserved Catalog HY29-0024/US

    Parker Hannifin CorporationHydraulic Pump Division14249 Industrial ParkwayMarysville, OH 43040 USAphone 937.644.4532fax 937.642.3639www.parker.com

    North AmericaIndustrialUSAChicago RegionNaperville, IL Tel: (630) 964 0796Great Lakes RegionFairlawn, OH Tel: (330) 670 2680Northeast RegionLebanon, NJ Tel: (908) 236 4121Pacific RegionBuena Park, CA Tel: (714) 228 2509Southern RegionAlpharetta, GA Tel: (770) 619 9767CanadaMilton, Ontario Tel: (905) 693 3000

    MéxicoToluca, Edo. de México Tel: (52) 72 2275 4200

    MobileUSAGlobal Mobile Lincolnshire, IL Tel: (847) 821 1500Central Region Lincolnshire, IL Tel: (847) 821 1500Eastern Region North Canton, OH Tel: (330) 284 3355Midwest Region Hiawatha, IA Tel: (319) 393 1221Southern Region Aledo, TX Tel: (817) 441 1794Western Region Buena Park, CA Tel: (714) 228 2509CanadaMilton, Ontario Tel: (905) 693 3000

    MéxicoApodaca, N.L. Tel: (52) 81 8156 6000

    TruckUSAEastern Region Cleveland, OH Tel: (440) 519 1125

    Western RegionSan Ramon, CA Tel: (925) 735 9573CanadaMilton, Ontario Tel: (905) 693 3000

    MéxicoApodaca, N.L. Tel: (52) 81 8156 6000

    EuropeAustriaWiener Neustadt Tel: (43) 2622 23501 0 BelgiumNivelles Tel: (32) 67 280 900Czech Republic and SlovakiaKlecany Tel: (420) 284 083 111DenmarkBallerup Tel: (45) 4356 0400FinlandVantaa Tel: (358) 20 753 2500FranceContamine-sur-Arve Tel: (33) 4 50 25 80 25GermanyKaarst Tel: (49) 2131 4016 0GreeceAthensTel: (30) 210 933 6450

    HungaryBudapest Tel: (36) 1 220 4155IrelandCounty Dublin, Baldonnell

    Tel: (353) 1 466 6370

    ItalyCorsico, Milano Tel: (39) 02 45 19 21

    The NetherlandsOldenzaal Tel: (31) 541 585000

    NorwaySki Tel: (47) 64 91 10 00

    PolandWarsaw Tel: (48) 22 57 32400

    PortugalLeca da Palmeira Tel: (351) 22 999 7360RomaniaBucharestTel: (40) 21 252 1382

    RussiaMoscow Tel: (7) 495 580 9145SloveniaNovo MestoTel: (386) 7 337 6650

    Spain Madrid Tel: (34) 91 675 7300

    SwedenSpanga Tel: (46) 8 597 95000

    UkraineKiev Tel: (380) 44 494 2731United KingdomWarwick, Tel: (44) 1926 317878

    Asia PacificAustraliaCastle Hill Tel: (61) 2 9634 7777

    ChinaBeijing Tel: (86) 10 6561 0520 Shanghai Tel: (86) 21 5031 2525

    Hong KongTel: (852) 2428 8008

    IndiaMahape, Navi Mumbai Tel: (91) 22 5613 7081

    KoreaSeoul Tel: (82) 2 559 0400

    MalaysiaSubang Jaya Tel: (60) 3 5638 1476

    New ZealandMt. Wellington Tel: (64) 9 574 1744

    JapanTokyo Tel: (81) 3 6408 3900

    SingaporeJurong Town Tel: (65) 6 887 6300

    TaiwanTaipei Tel: (886) 2 2298 8987

    ThailandBangkok Tel: (662) 717 8140

    Middle EastUnited Arab EmiratesAbu Dhabi Tel: (971) 2 678 8587

    Latin AmericaPan American DivisionMiami, FL Tel: (305) 470 8800

    ArgentinaBuenos Aires Tel: (54) 33 2744 4129

    BrazilCachoeirinha RS Tel: (55) 51 3470 9144

    VenezuelaCaracas Tel: (58) 212 238 5422

    AfricaSouth AfricaKempton Park Tel: (27) 11 961 0700