HYDRAULIC AND PNEUMATIC CONTROL ELEMENTS
![Page 2: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/2.jpg)
NECESSITY OF FLOW CONTROL VALVES The control of fluid dynamics is essential to ensure
efficient, reliable and safe operation of pumping systems. A pump puts fluid in motion by adding energy to it.
This kinetic energy, observed as pressure, is carried in the fluid and slowly lost to friction in the piping system.
Uncontrolled fluid in motion can physically destroy the pump, piping, valves, meters and other system components.
![Page 3: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/3.jpg)
FLUID CONTROL VALVESPressure Control Valves
Flow Control Valves
Direction Control Valves
1. Pressure Relief- Directly operated- Pilot operated
2. Counter balance
3. Pressure reducing
4. Sequencing valves
1. Non compensatedFlow Control valve
2. Pressure compensated
flow Control valve
3.Temp. compensated flow Control valve
1. 2/2, 3/2, 4/3 valves
2. Manually operated
3.Solenoid operated
4. Pilot operated
5. Cartridge valves
6. Check Valves- Directly operated - Pilot operated
Method of actuation1. Directly operated2. Pilot operated3. Manually operated4. Electrically operated
![Page 4: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/4.jpg)
PRESSURE CONTROL VALVES
1.Pressure Relief Valve
- Directly operated- Pilot operated
2. Pressure Control Valve
3. Sequence Valve
![Page 5: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/5.jpg)
1. PRESSURE RELIEF VALVE-This valve used to limits the pressure in the whole system.
-Also called as Safety valve or Maximum Pressure valve.
-Pressure relief valve is normally closed type valve.
-It is located between the Pump and direction control valve (Before the actuator)
Directly operated
![Page 6: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/6.jpg)
Pilot operated
![Page 7: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/7.jpg)
PRESSURE REDUCING VALVE
Directly operated
- Pressure reducing valve is used to maintain pressure in second branch of the system.
Main BranchP1
Second BranchP2
![Page 8: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/8.jpg)
SEQUENCE VALVE The sequence valve is used to supply the flow of fluid to second
consumer if requirement of first consumer is fulfilled. It consist of pilot relief valve. Also consist of two spools connected to each other.
![Page 9: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/9.jpg)
COUNTER BALANCE VALVE This valve is used to avoid uncontrolled movement of cylinder. This valve is used in earth moving equipments. It consist of two pilot relief valves are connected to each others. It holds the load for some time like lifting trolley of the tractors
or the trucks.
Fluid is controlled by resisting it from one side and free from its other side.
![Page 10: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/10.jpg)
FLOW CONTROL VALVE Flow control valve is used to control the flow rate in the system
according to system designed.
Flow rate is controlled by the throttling or the diverting.
Throttling means by using the orifices, throttle valves etc. and diverting means bypassing it to reservoir using the flow control valve.
![Page 11: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/11.jpg)
![Page 12: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/12.jpg)
NON-COMPENSATED FLOW CONTROL VALVE In such valves Pressure, velocity and flow rate will get varies. It
will not remain constant. The orifices, throttle valve are come in this above valve.
![Page 13: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/13.jpg)
![Page 14: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/14.jpg)
Pressure Compensated Flow control Valve
![Page 15: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/15.jpg)
Pressure - Temperature Compensated Flow control Valve
![Page 16: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/16.jpg)
Variable Flow control Valve
![Page 17: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/17.jpg)
Non return type Flow control Valve
![Page 18: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/18.jpg)
CHECK VALVE OR NON-RETURN VALVE This valve allows the flow of fluid in only one direction bur dose
not allow flow in other direction. Also called as Non Return valve.
Directly operated check valve (Poppet type)
![Page 19: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/19.jpg)
![Page 20: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/20.jpg)
Pilot operated check valve (Poppet type)
![Page 21: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/21.jpg)
Shuttle valve
![Page 22: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/22.jpg)
Quick Exhaust Valve
![Page 23: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/23.jpg)
DIRECTION CONTROL VALVE The Direction Control Valves are used to change the
direction of flowing fluid. We have required to move the actuator in the
different direction and it is actuated by supplying the fluid in different directions using D.C.V. 2/2
DCVPorts Positions
![Page 24: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/24.jpg)
![Page 25: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/25.jpg)
METHOD OF ACTUATIONS FOR D.C.V.
![Page 26: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/26.jpg)
![Page 27: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/27.jpg)
2/2 DIRECTION CONTROL VALVE
•This is the 2/2 DCV which is spring operated type.
•Here both OFF and ON positions of the valve are shown in the above figures.
•If fluid is coming from pump, the spring moves towards right and port P is connected to port A and fluid is supplied to actuator.
![Page 28: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/28.jpg)
3/2 DIRECTION CONTROL VALVE
P
A
R R
A
P3/2 DCV symbol
![Page 29: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/29.jpg)
4/2 DIRECTION CONTROL VALVE (SPOOL TYPE)
P
A
R R
A
P
B B
4/2 DCV symbol
![Page 30: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/30.jpg)
4/3 DIRECTION CONTROL VALVE 4/3 DCV having the 4 ports and 3 position for the
actuation of it. In three positions this valve will be actuated. The symbol of this particular (4/3 DCV) valve is given
below.
According to center positions of above valve it is classified in three types.
1. Closed Center position valve2. Open Center position valve 3. Tandem Center position valve
P
A
R R
A
P
B B
4/3 DCV symbol
A B
P R
![Page 31: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/31.jpg)
1. Closed Center position valve
2. Open Center position valve
3. Tandem Center position valve
• In this position all the ports are closed to each other.• Possibility of Heating and Damage
• In this position all the ports are open to each other.• No Possibility of Heating and Damage.• No work is done by any component.
• Used to holds the work load for some time period.• No heating and damaging. Also supply the fluid to other circuit so, extra power •station is required.
![Page 32: Hydraulic and pneumatic control elements](https://reader036.fdocuments.net/reader036/viewer/2022081507/5871aa541a28abda6a8b54cb/html5/thumbnails/32.jpg)
SEAT TYPE DCV (4/2 TYPE)